5
R CALL 1-800-999-3600 SUBJ ECT TO CHANGE W THOUT NOTCE" " ALLDMENSONS AND DESGN CRTERA PROJ ECT I ON T HI RD ANGLE ( DI MENSI ONS I N I NCHES) DI MENSI ONS I N MI LL I MET RES F I LE NO. 177 - 598 REV. 1 L 1020 PAGE 1 OF 5 ") 16 9 ( 14 ") 16 11 (18 474 ") 16 9 ( 14 502 ") 4 3 (19 206 " ) 8 1 ( 8 1125 " ) 16 5 ( 44 912 213 " ) 8 3 ( 8 " ) 16 15 ( 35 HEIGHT A B E F G H ") 8 1 (39 994 ") 8 7 (33 860 TOP FUNCTION KEY KEYPAD (TOP ROW) HEADPHONE JACK (ADA) C D HEADPHONE JACK (CSA) MOTORIZED CARD READER DIP CARD READER I ") 2 1 (34 875 ") 16 13 (42 1086 ") 4 1 (39 995 ") 4 1 (39 995 BAR CODE SCANNER RECEIPT/STATEMENT PRINTER ") 4 1 (47 1200 ") 16 5 (34 871 ") 4 3 (7 197 ") 16 11 (6 170 ") 8 3 (1 30 ") 16 13 ( 5 148 ") 2 1 ( 5 140 ") 16 1 (6 153 ") 8 3 (4 107 (5") 128 ") 16 13 (4 122 DEPTH SIDE VIEW 502 ") 4 3 (19 819 ( 2 " ) 51 " ) 8 1 ( 3 79 " ) 8 5 ( 19 498 " ) 8 1 ( 3 79 " ) 4 1 ( 32 1538 " ) 16 9 ( 60 ") 8 1 (3 79 ") 4 3 (4 121 ") 8 1 (3 79 A B C I D E G F H 1526 " ) 16 1 ( 60 AIR VENT AIR EXHAUST PLANNING AND SITE PREPARATION GUIDE TP-821482-001A. FOR ADDITIONAL DETAILS AND INFORMATION. PLEASE SEE CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH ® ") UL SAFE 2 1 WITH 13mm ( FRONT LOAD LOBBY UNIT OPTEVA 378 ENHANCED CASH RECYCLER TERMINAL PLAN VIEW FRONT VIEW J ") 16 7 (39 1002 HEIGHT - FROM BOTTOM OF SAFE DEPTH - FROM FRONT EDGE OF BEZEL TOP OF MONITOR ") 8 1 (51 1299 ") 4 1 ( 13 336 J ON PAGE 2 OF 5) (SEE "CAUTION LABEL" BAR CODE SCANNER OPTIONAL CONSUMER " ) LEVEL NG 8 7 0 mm T O 76 mm ( 0 " T O 5 CASH RECYCLER 160 ") 16 5 (6 279 477 ") 4 3 (18 (11")

OPTEVA 378 ENHANCED CASH RECYCLER ... - Diebold Nixdorf service terminals... · consult with diebold installation/service branch ® 2") ul safe with 13mm (1 front load lobby unit

  • Upload
    others

  • View
    53

  • Download
    3

Embed Size (px)

Citation preview

R

CALL 1-800-999-3600

SU

BJE

CT T

O C

HA

NG

E W

ITH

OU

T N

OTIC

E"

"ALL DIM

EN

SIO

NS A

ND D

ESIG

N C

RIT

ERIA

PR

OJE

CTIO

N

THIR

D A

NG

LE

(DIM

EN

SIO

NS I

N I

NC

HE

S)

DIM

EN

SIO

NS I

N M

ILLIM

ET

RE

S

FIL

E N

O. 177-5

98 R

EV. 1

L1020

PA

GE 1 O

F 5

")169(

14

")1611(18

474")16

9(

14

502

")43(19

206 ")8

1(8

1125

")16

5(4

4

912

213 ")8

3(8

")16

15

(35

HEIGHT

A

B

E

F

G

H

")81(39

994

")87(33

860

TOP FUNCTION KEY

KEYPAD (TOP ROW)

HEADPHONE JACK (ADA)

C

D

HEADPHONE JACK (CSA)

MOTORIZED CARD READER

DIP CARD READER

I

")21(34

875

")1613(42

1086

")41(39

995

")41(39

995

BAR CODE SCANNER

RECEIPT/STATEMENT PRINTER

")41(47

1200

")165(34

871

")43(7

197

")1611(6

170

")83(1

30

")1613( 5

148

")21( 5

140

")161(6

153

")83(4

107

(5")

128

")1613(4

122

DEPTH

SIDE VIEW

502

")43(19

819

(2")

51

")8

1(3

79

")8

5(1

9498

")8

1(3

79

")4

1(3

2

1538

")16

9(6

0

")81(3

79

")43(4

121

")81(3

79

A

B

C

I

D

E

G

F

H

1526

")16

1(6

0

AIR VENT

AIR EXHAUST

PLANNING AND SITE PREPARATION GUIDE TP-821482-001A.

FOR ADDITIONAL DETAILS AND INFORMATION. PLEASE SEE

CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH

®

") UL SAFE21WITH 13mm (

FRONT LOAD LOBBY UNIT

OPTEVA 378 ENHANCED CASH RECYCLER TERMINAL

PLAN VIEW

FRONT VIEW

J

")167(39

1002

HEIGHT - FROM BOTTOM OF SAFE

DEPTH - FROM FRONT EDGE OF BEZEL

TOP OF MONITOR")8

1(51

1299

")41( 13

336

J

ON PAGE 2 OF 5)

(SEE "CAUTION LABEL"

BAR CODE SCANNER

OPTIONAL CONSUMER

") L

EV

ELIN

G8

70

mm T

O 7

6m

m (0"

TO 5

CASH RECYCLER

160

")165(6

279 477

")43(18(11")

PR

OJE

CTIO

N

THIR

D A

NG

LE

SU

BJE

CT T

O C

HA

NG

E W

ITH

OU

T N

OTIC

E"

"ALL DIM

EN

SIO

NS A

ND D

ESIG

N C

RIT

ERIA

(DIM

EN

SIO

NS I

N I

NC

HE

S)

DIM

EN

SIO

NS I

N M

ILLIM

ET

RE

S

FIL

E N

O. 177-5

98 R

EV. 1

PA

GE 2 O

F 5

REQUIREMENTS

CONDUIT AND JUNCTION BOX

NOTE:

SIGNAL CABLE RUN CONSTRAINTS

CONDUIT FOR EXISTING CONSTRUCTION.

CONSTRUCTION OR BOXES CAN BE SURFACE MOUNTED WITH EXPOSED

BOXES CAN BE FLUSH MOUNTED WITH CONCEALED CONDUIT FOR NEW

LOCATE IN AN EASILY ACCESSIBLE AREA.

PLATE. (LENGTH OF ELECTRICAL POWER CABLE PROVIDED WITH UNIT).

JUNCTION BOXES MUST BE LOCATED WITHIN 2210mm (87") OF CONNECTING

WITH RESPECT TO OTHER POWER AND ELECTRICAL EQUIPMENT CABLE RUN.

THE FOLLOWING CHART ITEMIZES THE PHYSICAL SPACING REQUIREMENTS OF THE SIGNAL CABLE RUN

TYPE OF ELECTRICAL RUN

LIGHTING FIXTURES

FLUORESCENT, NEON OR INCANDESCENT

UNSHIELDED POWER LINE OR ELECTRICAL EQUIPMENT

WITH SIGNAL CABLES ENCLOSED IN GROUNDED CONDUIT

UNSHIELDED POWER LINES OR ELECTRICAL EQUIPMENT

CABLES IN GROUNDED CONDUIT

POWER LINES IN GROUNDED CONDUIT WITH SIGNAL

SIGNAL CABLE INSTALLATION CONSTRAINTS

BELOW 2 KVA 2-5 KVA ABOVE 5 KVA

127mm (5") 127mm (5") 127mm (5")

127mm (5") 305mm (12") 610mm (2'-0")

")2164mm (2 152mm (6") 305mm (12")

76mm (3") 153mm (6")

POWER REQUIREMENTS

100-127 VAC (+6%,-10%) 50Hz (+/-1%) SINGLE PHASE

100-127 VAC (+6%,-10%) 60Hz (+/-1%) SINGLE PHASE

200-240 VAC (+/-10%) 50Hz (+/-1%) SINGLE PHASE

200-240 VAC (+/-10%) 60Hz (+/-1%) SINGLE PHASE

100-127 VAC (+6%, -10%) SERVICE, DISCONNECT AT 20 AMPERES

200-240 VAC (~10%) SERVICE, DISCONNECT AT 10 AMPERES

WEIGHT OF UNIT

OPERATING ENVIRONMENTSAFE LOCATION

POWER USAGE

MACHINE STATUS

IDLE (NO TRANSACTION)

IN PROGRESS)

TRANSACTION (DISPENSE

CONFIGURATION

CASH DISPENSER, AND THE TYPE OF TRANSACTION THE CASH DISPENSER IS PERFORMING.

THE POWER USE DEPENDS ON THE NUMBER AND TYPE OF DEVICES PRESENT IN THE

HEAT OUTPUT CONFIGURATION

1

1

1

4

RECEIPT PRINTER, AND 5 CASSETTE DISPENSER.

PROCESSOR, COLOR LCD CONSUMER DISPLAY, MOTORIZED CARD READER,

SHORT-TERM AC POWER FLUCTUATIONS AS OUTLINED IN EN61000-4-11.

POWER CONDITIONING TO PREVENT THE TERMINAL FROM MALFUNCTIONING DUE TO

THE MODULE BULK POWER SUPPLY AND PROCESSOR POWER SUPPLY WILL PROVIDE

(OR CIRCUIT BREAKER) MUST TURN OFF THE LINE VOLTAGE AT THE FOLLOWING AMPERAGE.

BREAKER AT THE ELECTRICAL SERVICE PANEL. THE QUICK-DISCONNECT DEVICE

BY A SAFETY QUICK-DISCONNECT DEVICE TO BREAK LINE VOLTAGE (SUCH AS A CIRCUIT

POWER TO THE CASH RECYCLER IS TO BE A DEDICATED SERVICE AND MUST BE PROTECTED

SPECIFIED BELOW.

CORD WITH A COUNTRY SPECIFIC POWER PLUG. THE POWER SUPPLIED MUST BE AS

(CONDUIT GROUND IS NOT ACCEPTABLE). THE CASH DISPENSER WILL PROVIDE A POWER

RECEPTACLE. WIRING TO THE RECEPTACLE MUST INCLUDE A THIRD-WIRE EARTH GROUND

THE CASH RECYCLER REQUIRES A SINGLE-PHASE, THREE-WIRE UNSWITCHED POWER

1

3

4

2

1

3

REAR VIEWSIDE VIEW

2210mm (87")

POWER CORD

(ALL BY OWNERS E.C. ) (SEE POWER REQUIREMENTS).

CONNECTING PLATE. BOTTOM CONNECTION MUST BE COMPENSATED ACCORDINGLY

") DP. JUNCTION BOX WITH RECEPTACLE WITHIN 2210mm (87") OF SIDE81X 54mm (2

") METAL CONDUIT AND UNSWITCHED ELECTRICAL SUPPLY TO 102mm (4") SQ.4319mm (

DIEBOLD TO PROVIDE FLAT COVER WITH TAMPER SWITCH.

") DP. JUNCTION BOX (ALL BY OWNERS E.C. )81102mm (4") SQ. X 54mm (2

25mm (1") METAL CONDUIT FROM ALARM CONTROL CABINET JUNCTION BOX TO

") RIGID CONDUIT FROM JUNCTION BOX TO CABLE CONNECTING PLATE.4319mm (

") LIQUID TIGHT FLEX METAL CONDUIT OR 43OWNERS E.C. TO RUN 19mm (

FROM SIDE OF UNIT.

PLUG-IN CONNECTOR SUPPLIED WITH UNIT. POWER CORD LENGTH 2210mm (87")

OWNERS E.C. TO SUPPLY COMPATIBLE RECEPTACLE FOR COUNTRY SPECIFIC

")85(4

117

")167(1

36

")8

1(3

79

")8

7 (

22

")81(3

79

")83(13

340

")41(3

83

695

")16

9(1

40

")16

1(2

1534

")16

9(1

40

")8

3(2

7

AIR INTAKE

AIR INTAKE

INTAKE

AIR

AIR EXHAUST

665kg (1466 LBS.)

230 WATTS

390 WATTS

20 TO 55% AT 38º C (100º F)

20 TO 80% AT 32º C (90º F),

RELATIVE HUMIDITY ( NON-CONDENSING )

10º C TO 38º C (50 F TO 100º F)

1331 BTU/HR DISPENSING

785 BTU/HR IDLE

79

")8

1(3

42

")16

11

(1")16

331mm (1

INSTALLATION GUIDELINES AND REGULATIONS.

WITHSTAND AS MUCH STRAIN IN INSTALLATION. CONSULT LOCAL CODES FOR SIGNAL CABLE

LIGHTING CABLE, SIGNAL CABLES HAVE SMALL CONDUCTORS AND LIGHT INSULATION AND WILL NOT

RELATIVE CARE IS REQUIRED WHEN INSTALLING SIGNAL CABLES IN CONDUITS, UNLIKE POWER AND

SEPARATION FROM OTHER CABLES

CAUTION LABEL

") LEVELING870mm TO 150mm (0" TO 5

1

2

3

201

")167(6

163

")43(21

552

")1615(7

118

")81(3

79

")1613(7

198

")81(3

79")16

1(3

78

")85(4

R

CALL 1-800-999-3600

PR

OJE

CTIO

N

THIR

D A

NG

LE

SU

BJE

CT T

O C

HA

NG

E W

ITH

OU

T N

OTIC

E"

"ALL DIM

EN

SIO

NS A

ND D

ESIG

N C

RIT

ERIA

(DIM

EN

SIO

NS I

N I

NC

HE

S)

DIM

EN

SIO

NS I

N M

ILLIM

ET

RE

S

FIL

E N

O. 177-5

98 R

EV. 1

PA

GE 3 O

F 5 ( MINIMUM SERVICE AREA )

PLAN VIEW

NOTE:

MINIMUM SERVICE AREA

MUST ENTER UNIT IN THIS AREA

ALL ELECTRICAL AND DATA CABLES

(2")

51

(2")

51

300

(6")

152

")8

7(7

200

")16

13

(11

948

")165(37

1007

")85(39

( RECOMMENDED SERVICE AREA )

PLAN VIEW1581

")8

5(1

9499

")4

1(6

2

VA

RIE

S

800

")1613(11

300

")21(31

2799

")163(110

2990

")1611(117

1450

")8

1(5

3

1349

")16

1(5

7

2799

")16

3(1

10

300

(6")

152

")8

7(7

200

")16

13

(11

1349

")8

5(6

41641

")8

1(5

3

2990

")32

23

(117

SPECIAL BUILDING CONDITIONS.

INSTALLATION/SERVICE BRANCH FOR

TIME. CONSULT WITH DIEBOLD

INCREASE IN INSTALLATION AND SERVICE

RECOMMENDED AREA MAY RESULT IN AN

USE OF ANY AREA LESS THAN THE

INSTALLATION AND SERVICE ACCESS.

WHEREVER POSSIBLE TO IMPROVE

DIMENSIONS SHOWN MAY BE INCREASED

REQUIRED FOR INSTALLATION AND SERVICE.

SHOWN IS THE MINIMUM/RECOMMENDED AREA

SERVICE THE TERMINAL

SHOULD ALLOW A PERSON TO STAND AND

HEIGHT OF SPACE IN FRONT OF TERMINAL SIDE VIEW( MINIMUM/RECOMMENDED SERVICE AREA )

278

")1615(2

75

")1611(18

474

")43(4

121

")1615(10

RECOMMENDED SERVICE AREA

213

")1615(2

75

")1611(18

474

")85(9

245

")83(8

") UL SAFE21WITH 13mm (

FRONT LOAD LOBBY UNIT

OPTEVA 378 ENHANCED CASH RECYCLER TERMINAL ®

PR

OJE

CTIO

N

THIR

D A

NG

LE

SU

BJE

CT T

O C

HA

NG

E W

ITH

OU

T N

OTIC

E"

"ALL DIM

EN

SIO

NS A

ND D

ESIG

N C

RIT

ERIA

(DIM

EN

SIO

NS I

N I

NC

HE

S)

DIM

EN

SIO

NS I

N M

ILLIM

ET

RE

S

FIL

E N

O. 177-5

98 R

EV. 1

PA

GE 4 O

F 5

(MINIMUM SERVICE AREA)

PLAN VIEW - ADJACENT UNITS

(2")

51

MINIMUM SERVICE AREA

MUST ENTER UNIT IN THIS AREA

ALL ELECTRICAL AND DATA CABLES

300

")16

7(2

7697

(6")

152

")8

7(7

200

")16

13

(11

1349

")16

1(5

71450

")8

1(5

3

2799

")16

3(1

10

278

")1615(2

75

")1611(18

474

")1611(15

399

")1611(18

474

")1611(15

399

")1611(18

474

")43(4

121

")1615(10

2694

")161(106

636

")41(12

312

")83(34

873

")83(34

873

")161(25

FOR ADDED SECURITY:

ANCHORING THE CASH RECYCLER TO CONCRETE FLOORS:

ANCHORING THE CASH RECYCLER TO WOOD FLOORING:

ALARM CABLES (SIDE ENTRY)

") DIA. HOLE FOR8129mm (1

(SIDE ENTRY)

AND DATA CABLES

OPENING FOR POWER CORD

NOTES:

474

")1611(18

122

")43(3

96

")81(10

256

")1613(4

980

")16

9(3

8

702

")16

7(9

240

")2

1(1

38

")8

5(2

7

1 1

11

1

PLAN VIEW-SAFE FLOOR

POWER CABLE PLATE DETAIL

ANCHORING THE CASH RECYCLER TO STEEL FLOORS:

RECYCLER.

OF THE SAFE AS VIEWED FROM THE FRONT OF THE CASH

RECYCLER. THE CABLE ENTRY OPENING IS ON THE RIGHT SIDE

ENTER FROM THE SIDE OR OPTIONALLY FROM UNDER THE CASH

OF THE SAFE OVER THE CABLE ENTRY OPENING. CABLING CAN

POWER CABLE PLATE WHICH IS ATTACHED TO THE INSIDE WALL

CABLES ENTERING THE CASH RECYCLER PASS THROUGH THE

THROUGH A CABLE ENTRY OPENING ON THE SIDE OF THE SAFE.

ELECTRICAL AND DATA CABLING ENTERS THE CASH RECYCLER

2

30

")163(1

414

30

")163(1

")165 (16

70

")4

3(2

810

")8

7(3

1

100

")16

15

(3

2 2

22

") DIA. LEVELING LEG HOLES169 (4) 14mm (

(SEE NOTE)

CABLE ENTRY OPENING

CABLE ENTRY NOTE:

") UL SAFE21WITH 13mm (

FRONT LOAD LOBBY UNIT

OPTEVA 378 ENHANCED CASH RECYCLER TERMINAL ®

METHOD FOR YOUR INSTALLATION.

ANCHOR BOLTS. USE THE FOLLOWING GUIDELINES TO DETERMINE THE APPROPRIATE

IT IS RECOMMENDED THAT THE CASH RECYCLER SAFE BE SECURED TO THE FLOOR WITH

TERMINAL IS ANCHORED. REFER TO VIEW "A" AND "B" FOR ADDITIONAL DETAILS.

TERMINAL IS EQUIPPED WITH LEGS, THE LEVELING LEGS MUST BE REMOVED BEFORE THE

THICKNESS. ANCHOR BOLTS MUST BE USED IN ALL AVAILABLE ANCHOR HOLES. IF THE

OF 102mm (4") THICK FOR ANCHORING TO BE EFFECTIVE. THERE IS NO LIMIT FOR MAXIMUM

THAT IS 203mm (8") LONG. CONCRETE FLOORS OR CONCRETE BASES MUST BE A MINIMUM

") ANCHOR BOLT43WHENEVER POSSIBLE. DIEBOLD RECOMMENDS USING A M20 OR 19mm (

IT IS RECOMMENDED THAT THE CASH RECYCLER BE ANCHORED TO CONCRETE FLOORS

WILL BE LESS THAN THAT OF CONCRETE FLOORS.

THICK. IT IS IMPORTANT TO NOTE THAT THE OVERALL HOLDING CAPACITY OF A WOOD FLOOR

") 41TO PROVIDE ADDITIONAL STRENGTH. THE REINFORCEMENT PLATE IS TYPICALLY 6mm (

TO A LOCALLY FABRICATED REINFORCEMENT PLATE INSTALLED UNDERNEATH THE FLOOR

BEAMS FOR MAXIMUM HOLDING CAPACITY. ADDITIONALLY, THIS HARDWARE MUST ATTACH

PREFERRED THAT THE HARDWARE BE ATTACHED THROUGH SUPPORTING POSTS OR

BEAMS CAN BE SECURED BY A MACHINE-THREADED NUT AND BOLT METHOD. IT IS

CASH RECYCLERS INSTALLED ON WOOD FLOORS OR FLOORS SUPPORTED BY WOODED

").21THICKNESS MUST BE AT LEAST 13mm (

FLOOR TO PROVIDE ADDITIONAL STRENGTH. THE COMBINED BACKING PLATE AND FLOOR

ATTACH TO A LOCALLY FABRICATED REINFORCEMENT PLATE INSTALLED UNDERNEATH THE

POSTS OR BEAMS FOR MAXIMUM HOLDING CAPACITY. ADDITIONALLY, THIS HARDWARE MUST

METHOD. IT IS PREFERABLE THAT THE HARDWARE BE ATTACHED THROUGH SUPPORTING

CASH RECYCLER INSTALLED ON STEEL FLOORS CAN BE SECURED BY A MACHINE-THREADED

(4) 25.4mm (1") DIA. FLOOR MOUNTING HOLES

147

")16

9(2

7700

")16

13

(5

DIEBOLD PART NUMBER 29-016376-000A, HILTI PART NUMBER 282520).

")-10 X 203mm (8") LONG WEDGE ANCHORS (SUPPLIED BY OWNER'S INSTALLER) 4319mm (

WHEN POSSIBLE AND TO BE SECURED TO THE CONCRETE FLOOR WITH (4)

IN CONCRETE FLOOR (RECOMMENDED DRILLING COMPLETELY THROUGH FLOOR

") DIA. X 203mm (8" MIN.) DEEP HOLES43OWNER'S INSTALLER TO DRILL (4) 19mm (

(8")

203

MIN.

(4")

102

MIN.

VIEW "A" VIEW "B"

203mm (8")

MINIMUM HOLE DEPTH

102mm (4")

MINIMUM CONCRETE DEPTH

SAFE FLOOR SAFE FLOOR

PR

OJE

CTIO

N

THIR

D A

NG

LE

SU

BJE

CT T

O C

HA

NG

E W

ITH

OU

T N

OTIC

E"

"ALL DIM

EN

SIO

NS A

ND D

ESIG

N C

RIT

ERIA

(DIM

EN

SIO

NS I

N I

NC

HE

S)

DIM

EN

SIO

NS I

N M

ILLIM

ET

RE

S

FIL

E N

O. 177-5

98 R

EV. 1

PA

GE 5 O

F 5

R

CALL 1-800-999-3600