Magnetic StirrerRT Touch 17 and RT Touch 22Operation Manual 9240-11-014

Page 2: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

Thermo Scientific

MANUAL NUMBER 9240-11-014

0 -- 11/5/13 Original ccs

REV ECR/ECN DATE DESCRIPTION By

Preface

Magnetic Stirrer i

Important Before using this product, read this entire operation manual carefully. Users shouldfollow all of the operational guidelines contained in this manual and take all necessary safetyprecautions while using this product. Failure to follow these guidelines could result in potentiallyirreparable bodily harm and/or property damage. s

Caution All internal adjustments and maintenance must be performed by qualified service personnel. s

Material in this manual is for information purposes only. Thermo Fisher Scientific is committed to a continuingprogram of product development and improvement, and reserves the right to change information, such asspecifications, appearance, and dimensions, described in this document without notice. Thermo makes norepresentations or warranties with respect to this manual. In no event shall Thermo be held liable for anydamages, direct or incidental, arising out of or related to the use of this manual.

No part of this manual may be reproduced or transmitted in any form or by any means, includingphotocopying, recording, or using information storage and retrieval systems, for any purpose other than thepurchaser's own use, without the express written permission of the manufacturer.

Any other product names and services identified in this manual are trademarks or registered trademarks of theirrespective owners. No such use, or the use of any trade name, is intended to convey endorsement or otheraffiliation with Thermo Fisher Scientific.

©2013 Thermo Fisher Scientific. All rights reserved.

Page 3: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

Thermo Scientificii Magnetic Stirrer

Preface

This manual contains important safety and operation information. You must carefully read, understand, andfollow all the instructions in this manual prior to operating this instrument. Keep this manual in a safe placenearby for reference and make it easily available to all users.

1) This manual highlights DANGER/WARNING/CAUTION/NOTICE alerts to prevent injury or propertydamage and also to achieve optimum performance of your instrument.

(2) These alerts are classified into four types in this manual depending on the importance and the risk levels asdescribed below:

3) The claim which is out of the quality guarantee published by the Manufacturer is out of Manufacturer’sresponsibility.

4) The damage which is from unexpected fault or damage of user by Acts of God is out of Manufacturer’sresponsibility.

Symbols Meaning

Indicates a hazardous situation which, if not avoided, will result indeath or serious injury.

Ignoring this warning could cause serious injury or even death.

Ignoring this caution could cause injury or property damage.

Ignoring this notice could cause operational problems.

Page 4: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

Thermo Scientific Magnetic Stirrer iii

Preface

Do You Need Information or Assistance on

Thermo Scientific Products?

If you do, please contact us 8:00 a.m. to 6:00 p.m. (Eastern Time) at:

1-740-373-4763 Direct

1-800-438-4851 Toll Free, U.S. and Canada

1-877-213-8051 FAX

http://www.thermoscientific.com Internet Worldwide Web Home Page

[email protected] Tech Support Email Address

Certified Service Web Page

Thermo Fisher Scientific

401 Millcreek Road, Box 649

Marietta, OH 45750

Our staff can provide information on pricing and give you quotations. We can

take your order and provide delivery information on major equipment items or make

arrangements to have your local sales representative contact you. Our products are listed on the

Internet and we can be contacted through our Internet home page.

Our staff can supply technical information about proper setup, operation or

troubleshooting of your equipment. We can fill your needs for spare or replacement parts or

provide you with on-site service. We can also provide you with a quotation on our Extended

Warranty for your Thermo Scientific products.

Whatever Thermo Scientific products you need or use, we will be happy to discuss your

applications. If you are experiencing technical problems, working together, we will help you

locate the problem and, chances are, correct it yourself...over the telephone without a service

call.

When more extensive service is necessary, we will assist you with direct factory trained

technicians or a qualified service organization for on-the-spot repair. If your service need is

covered by the warranty, we will arrange for the unit to be repaired at our expense and to your

satisfaction.

Regardless of your needs, our professional telephone technicians are available to assist you

Monday through Friday from 8:00 a.m. to 6:00 p.m. Eastern Time. Please contact us by

telephone or fax. If you wish to write, our mailing address is:

International customers, please contact your local Thermo Scientific distributor.

Sales Support

Service Support

www.unitylabservices.com

Page 5: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

Magnetic Stirrer ivThermo Scientific

Table of Contents

Warnings and Cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1

Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2

Unpacking and Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1Check Instrument Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1Arrangement of Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-2Location Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-2Environmental Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-2Support Rod Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-3Setting Up Plate Cover on Top Plate . . . . . . . . . . . . . . . . . . . . . . . . .3-3Connecting to the Mains Power Supply . . . . . . . . . . . . . . . . . . . . . . .3-4Stirring Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-5

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-1Controller Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-2Controller Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . .4-2Controller Settings Flowchart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-3

Verification of Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-4To Change RPM During Stirring . . . . . . . . . . . . . . . . . . . . . . . . . .4-4How to Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-4

RPM Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-4How to Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-5

Timer Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-5To Stop Manually During Stirring . . . . . . . . . . . . . . . . . . . . . . . . .4-6To Monitor Operation Status During Stirring . . . . . . . . . . . . . . . . .4-7How to Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-8

Program Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-8Manual Stop During Stirring . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-9Monitoring Operation Status During Stirring . . . . . . . . . . . . . . . .4-10

Exit Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-11

Section 1

Section 2

Section 3

Section 4

Page 6: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

v Magnetic Stirrer Thermo Scientific

Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-1To Store the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-2

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-1

Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-1

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-1Test Standard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-2Disposing of the Product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-2

Warranty Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-1

Table of Contents

Section 5

Section 6

Section 8

Section 9

Section 7

Page 7: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

Magnetic Stirrer 1-1Thermo Scientific

Section 1 Warnings and Cautions

Ignoring the following warnings could cause serious injuries or even fatalaccidents.

Check and connect properly -the voltage, phase and capacity of powersupply on the ID plate before installation.

Power supply must be properly grounded. Abnormal grounded connectioncauses serious damage. Grounded connection must not be on the water pipeand gas pipe.

Use correct and provided power code. Power cord: Wall outlet withgrounded terminal power cord 250V 7A.

Do not install the product in a place that the gas could leak out. Do notuse in a place that has the industrial oil smoke and the metallic dust. Itcauses fire or electric shock. Do not use the machine near to places wherean explosion could happen due to organic evaporating gases. Explosive materials: Acid, Esther, Nitro compound. Inflammable materials: Salt peroxides, inorganic peroxide, salt acids.

With stirrer explosive and flammable chemicals (alcohol, benzene,etc), use with sufficient safety countermeasures. The flammable organicsolvents, dust, and corrosive gas may explode during stirrer sample.In accordance with an experiment, equipment of explosion-proof and airexhauster should be used in your laboratory. Also suitable stirrer RPM defenseshould be used on your sample.

Check equipment for permissible environmental conditions when usedinside a Temp & Humidity Chamber or Incubator. Fire or trouble could becaused by stirrer electricity, electronic, and damage of motor.Stirrer Permissible environmental conditionTemperature 5°C to 40°C Maximum relative humidity 80%.

Unplug, when there is strange sound, smell and smoke from theproduct. Stop operating and request the service.

Keep out of the direct sunlight. It may influence product life and properoperation.

Do not use the machine at places where moisture is high and floodingcan be happened.

Do not assemble, repair, modify on your own. Product may not work welland electric shock is possible. This will void the warranty.

Page 8: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

1-2 Magnetic Stirrer Thermo Scientific

Section 1Warnings and Cautions

Indicates a hazardous situation which, if not avoided, may result in minor ormoderate injury.

Do not put heavy things on the power cord. Do not put the unit on thecord. It may take off the wire coating and cause electric shock or fire.

Do not touch it with wet hands and put the main plug correctly. It maycause electric shock or injuries.

Install the power outlet near instrument for convenience.

Do not install the stirrer near machinery generating high frequencynoise. Avoid close installation to any high frequency- welding machine,sewing machine, and mass SCR controller.

Do not inject any liquid and inflammable things inside of product.

Do not pour water or put liquid on the top of the product whencleaning. Interrupt the main power immediately and request service whenwater may be in the product.

Do not let the product take any strong shock or vibration. It causesabnormal operation or trouble. It may deteriorate the operational ability of theproduct and may not obtain correct results.

Do not sprinkle insecticide or flammable spray on the product. Usesmooth cloths. Cleaning with solvent can cause fire and deformity.

Power off while cleaning product. It may cause the electric shock or fire.

Disconnect the power plug if strange sounds and burning smell, orsmoke occur. Request service.

Do not let the product take a shock or fall. It will cause wrong operationand malfunction.

Page 9: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

Magnetic Stirrer 2-1Thermo Scientific

Section 2 Functional Description

Magnetic Stirrer RT Touch-17 and Magnetic Stirrer RT Touch-22 areeconomically compact and lightweight magnetic stirrers under any kind ofexperimental lab environment. These magnetic stirrers have an operatingrange of 30rpm ~ 2,000rpm. By exact speed and powerful performance,they provide stirring of high viscosity solutions.

This magnetic stirrer is designed for user safety in a laboratory. A list of theconvenience features follow.

(1) Non- slip plate covers helps prevent glass flasks, beakers, etc. fromsliding easily.

(2) Each RPM adjusts real-time stirring with a quick action.

(3) Non- spark BLDC (Brushless Direct Current) motor stirring offerssafety and high quality durability in laboratory.

(4) Basic white and black plate cover allow monitoring of various colorsamples.

(5) The controller display adopts VFD (Vacuum Fluorescent Display). Iteasily indicates stirrer set up and operating conditions.

(6) The timer mode function can reserve stirrer stop time.

(7) Two different speeds and the number of repetitions can be set to forthe stir operation (program function). The stirrer can also be set forvarious users during experimental conditions. Program mode assists toeasily sample solvent with changeable viscosity, dependent on thestirrer (RPM).

(8) The stirrers offer stabilized rotations rate environment even fewer than50 rpm by BLDC (Brushless Direct Current) motor with joinedmagnetic bar. The product can be used in microbe cultivation. It canprovide the optimized environmental conditions with minimal physicaldamage.

Features

Page 10: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

2-2 Magnetic Stirrer Thermo Scientific

Section 2Functional Description

Features (continued) (9) The control system composed RPM (Revolution Per Minute) settingrate increase progressively, and the system prevents user and productfrom the splashing of imminently solvent rotation.

(10) The user can easily use the capacitive touch sensor button and the dialbutton to control and set the stirrer.

(1) Plate cover: Non-slip silicone covers protect sliding of glass flask andbeaker, etc.

(2) Top plate: Protect stirrer inside and prevent liquid inflow.

(3) Mode button: The button adjust controller function mode.

(4) VFD panel & controller: The panel indicates product setting andcontrol condition.

(5) Dial type knob: The dial set up controller function.

- Dial left turn/right turn: Operating rate setting

- Dial push: Operation rate saving, Start / Stop

(6) Foot: Non-marking feet allow for easy movement.

ConstructionPlate Cover

Mode Button

VFD Panel andController

Dial Type Knob

Foot

Top Plate

Figure 2-1. Controller

Page 11: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

Magnetic Stirrer 2-3Thermo Scientific

Section 2Functional Description

Construction(continued)

(7) Threaded hole for support rod: This support rod can be installed witha thermometer, temperature sensor, or clamp on top of the body.

(8) Socket: Connect the power cable to the socket located on the back sideof the unit.

(9) Power switch: Main ON/OFF switch and power source of the product.

Figure 2-2. Back View

Hole forSupport Rod

Socket

Power Switch

Page 12: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

Magnetic Stirrer 3-1Thermo Scientific

Section 3 Unpacking and Installation

Follow the steps below when unpacking.

(1) Check to see if there is any damage in the instrument package beforeunpacking.

(2) Unpack the instrument carefully.

(3) Inspect to see that the instrument was not damaged duringtransportation.

(1) After unpacking, check the instrument components supplied in thepackage.

(2) If a noticeable issue or an omission is found, immediately notify yourlocal Thermo Scientific dealer’s Service Department.

Check InstrumentComponents

COMPONENT/MODEL Figure QUANTITY DESCRIPTION

Operation Manual 1

Main power cord 1 Free voltage and frequency(AC 100 ~ 240V, 50/60Hz)

Plate Cover 1/1 (white 1ea & black 1ea)

Magnetic Stirring Bar 1 30 x 8mm (mm x Ø, Length)

Page 13: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

3-2 Magnetic Stirrer Thermo Scientific

Section 3Unpacking and Installation

EnvironmentalConditions

Location Conditions

Arrangement of Unit

The unit should be installed in a suitable environment as described below.

• Avoid direct sunlight.

• Room temperature should be 5°C ~ 40°C

• Relative Humidity (RH%) should be less than 80%.

• Altitude should be less than 2,000m.

Place the unit far from other instruments and and keep a proper distancebetween it and other apparatuses (normally more than 30cm).

• Do not place the unit near other laboratory equipment which can be readilyinfluenced, even by weak motor vibration, or by magnetic force because theunit creates a magnetic field.

• The unit can cause a magnetic field. Do not place especially the electricdevices on top plate due to inducing the strong magnetic field.

• Do not use the plastic beaker when operating the unit in explosiveatmospheres.

• The plastic beaker can cause the magnetic field, resulting in igniting toexplosive substances.

• Place the unit on the table. Check to make sure the non-slip feet aresecured tightly to the unit.

• Ensure that the unit will be parallel to the table.

Page 14: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

It can be possible to cover the top plate with sticky material on top plate,for prevention of slipping and out of tracking during the test. It’s anoptional according to user’s test purpose.

(1) Cover the plate cover on top plate.

(2) Make sure that the plate cover’s stuck tight on top plate.

According to user’s test purpose, this support rod can be installed with athermometer, or clamp on top of the body.

*List for Accessories*Temp Sensor for stirring (clamp holder and rod are optional)

Magnetic Stirrer 3-3Thermo Scientific

Section 3Unpacking and Installation

Figure 3-1. Plate Cover on Top Plate

Plate Cover

Top Plate

Figure 3-2. Installing a Temp Sensor Figure 3-3. Securing a Round Flaskwith a Clamp

Setting Up PlateCover on Top Plate

Support RodInstallation

Page 15: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

Connect the electric power to the unit according to the following process.

(1) Switch off the main switch before connecting power cable.

(2) Connect the power cable to the socket located on the back of the unit.

• The voltage, phase & power consumption stated on the type plate mustcorrespond to the mains voltage.

• Failure to connect to a proper connection of a power supply will cause therisk of fire, electric shock, and personal injury.

• Never use a forked socket, or a double-tapped socket.

• Failure to obey a safety instructions will result in causing burning the cable,or risk of fire.

• Use only the main power cord recommended by the manufacturer orsupplied with the unit.

3-4 Magnetic Stirrer Thermo Scientific

Section 3Unpacking and Installation

Connecting to theMains Power Supply

Main SwitchSocket

OFF

ON

Figure 3-3. Connect to Power

Figure 3-3. Connect Cable to Socket

Page 16: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

(1) Pour the liquids to be mixed into the flask, or the beaker.

(2) Place the stirring bar at the center of the container.

(3) Place a beaker or glass container on top of top plate, or plate cover.

• Maximum load to be placed on top plate cannot exceed 25kg total.

Magnetic Stirrer 3-5Thermo Scientific

Section 3Unpacking and Installation

Stirring Operation

Page 17: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

Magnetic Stirrer 4-1Thermo Scientific

Section 4 Operation

(1) Mode key; selects timer and program mode. It senses and respondswith even very light touch because of adoption of electric capacitytype.

a. Start and stop: Red color

b. Mode selection: Blue color

c. During inputting value: Pink color

(2) Controller with VFD typedisplay; helps monitoring,adjusting, and verifying setvalue and control status.

a. Rem’n: Remaining time

b. Run: Unit is operating.

c. Stop: it indicates unit is stop status.

d. Rpm: It indicates stirring speed status.

e. Time: It displays Timer status.

f PV: It indicates the present (current) stirring speed.

g. SV: It indicates the set (desired) stirring speed.

h. hr: HH:MM

i. X10: Conversion stirring value of current RPM

(3) Dial Knob : start, stop, input and set value.

Figure 4-1. Control Panel and Function

Page 18: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

(1) RPM mode: Set speed to operate stirring.

(2) TIME mode: Set both timer and speed to operate stirring.

(3) PROG. mode: It sets 2 different speed and number of repetition tooperate stirring.(Program function)

(4) EXIT mode: It returns unit to standby status.

(1) RPM: stirring speed

(2) TIME: Hour/Minute

(3) TIME MODE: Timer mode

(4) PROG MODE: Program mode

a. 1ST: 1st step stirring speed.

b. 2ND: 2nd step stirring speed.

c. INFI: Unlimited repetition

d. CONT: Number of repetition

(5) STOP

(6) CONT: Continuous operation

(7) SUCC SET: Setting completion and saved.

(8) EXIT: Returns to standby status

(9) END: This indicates expiration of Timer mode or Program mode.

4-2 Magnetic Stirrer Thermo Scientific

Section 4Operation

Controller FunctionalDescription

ControllerDescription

Page 19: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

Magnetic Stirrer 4-3Thermo Scientific

Section 4Operation

There are 3 operation modes.

Control status can be moved and chosen from standby status to each RPMmode, Timer mode, Program mode top operate stirrer.

Controller SettingsFlowchart

FunctionH

ow to operate

Page 20: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

Set RPM to operate stirring.

(1) Press power switch to turn on. (Refer to 3.4 power connection, Page12)

[Booting display] [Standby display]

(2) Rotate dial knob to set and adjustRPM.

(3) Press dial knob 1 time to start stirring.

(4) Actual RPM reaches set value.

(5) Press dial knob to stop stirring.

(1) Rotate dial knob to change RPM.

(2) Actual RPM reaches modified RPM value.

(1) Press mode key. * Operating time and set RPM display.

(2) Press mode key again. * It returns to RPM display.

4-4 Magnetic Stirrer Thermo Scientific

Section 4Operation

RPM Mode

How to Set

Pressany key

Operatingtime

To Change RPM DuringStirring

Verification of Timer

[RPM display] [Operating time display]

Page 21: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

Set RPM and stirring time.

(1) Press power switch to turn on. Refer to 3 Power Connection.

[Booting display] [Standby display]

(2) Press Mode key. * Display converts to Timer mode.

• If mode key does not work, turn off power switch and turn it on again.*Repetition of Step 1.

(3) Press dial knob and display converts to input display of hour andminute.

* How to input hour and minute

- Numbers are blinking which means standby status.

a. Rotate dial knob to set hour.

b. Press dial knob.

c. Rotate dial knob to set minute.

d. Press dial knob to save time and display converts to next step,RPM set status.

Magnetic Stirrer 4-5Thermo Scientific

Section 4Operation

Timer Mode

How to Set

Page 22: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

(4) Rotate dial knob to set RPM.

(5) Press dial knob to save and operate RPM.

[Save display] [Operating display]

(6) When timer expires, stirring stops with alarm sounding for 3 seconds.

• All kind of input or set status are cancelled when mode key is pressed. Andunit returns to standby status. ※ Possible cancellation: Step 2 ~ Step 4.

Stirring can be stopped before timer expires.

(1) Press dial knob. STOP/CONT display and STOP blinks.

(2) Rotate dial knob. Either STOP or CONT blinks when you rotate dialknob. Stop rotating dial knob when STOP blinks.

4-6 Magnetic Stirrer Thermo Scientific

Section 4Operation

How to Set (continued)

To Stop Manually DuringStirring

Page 23: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

(3) Press dial knob and stirring stops. * If you choose CONT – Stirringcontinues until timer expires.

* If you choose STOP – Stirring stops.

[Standby display]

* Press Mode key or dial knob to convert from Timer expiration display toStandby display.

(1) Press mode key. * Remaining time and set RPM.

(2) Press mode key. * It returns to RPM display.

[RPM display] [Remaining time display]

* Stirring ends*

When timer expires, TIME END displays. Once you press mode key ordial knob, it returns to standby status.

Magnetic Stirrer 4-7Thermo Scientific

Section 4Operation

To Stop Manually DuringStirring (continued)

Pressany key

To Monitor OperationStatus During Stirring

Page 24: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

Two sets of different RPM and Timer can be programmed and repeated.

(1) Press power switch to turn on. Refer to Section 3 Power Connection.

[Booting display] [Standby display]

(2) Press mode key and rotate dial knob clockwise 1time. The followingdisplays.

• If Program mode does not display even touch and press mode key and dialknob, turn off power switch and turn it on again. * Repetition of Step 1.

(3) Press dial knob. Rotate dial knob to set 1st RPM and press dial knobafter completion of RPM setting. * 1st step RPM setting.

(4) Rotate dial knob to set hour and minute. * This is to set timer of 1ststep RPM (RPM of Step 3).

(5) Rotate dial knob to set 2nd RPM and press dial knob after completionof RPM setting. * 2nd step RPM setting.

4-8 Magnetic Stirrer Thermo Scientific

Section 4Operation

Program Mode

How to Set

Page 25: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

(6) Rotate dial knob to set hour and minute. * This is to set timer of 2ndstep RPM (RPM of Step 5).

(7) Rotate dial knob and set number of repetition of 1st and 2nd of RPMand Timer. * Set number of repletion of saved 1st, 2nd RPM andTimer.

[INFI: Unlimited repetition] [Set number of repetition]

(8) Press dial knob to save and operate stirring as programmed.

(9) When program expires, stirring stops with alarm sound for 3 seconds.

• All kind of input or set status are cancelled when mode key is pressed. Andunit returns to standby status. * Possible cancellation: Step 2 ~ Step 8.

Stirring can be stopped before program timer expires.

(1) Press dial knob. STOP and CONT displays.

Magnetic Stirrer 4-9Thermo Scientific

Section 4Operation

How to Set (continued)

Manual Stop DuringStirring

Page 26: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

(2) Rotate dial knob. Either STOP or CONT blinks when you rotate dialknob. Stop rotating dial knob when STOP blinks.

(3) Press dial knob and stirring stops.

* If you choose CONT – Stirring continues until program expires.

* If you choose STOP – Stirring stops.

[Standby display]

* Press Mode key or dial knob to return to Standby display.

(1) Press mode key. * Remaining time and set RPM display.

(2) Press mode key. * It returns to RPM display.

[RPM display] [Remaining time display]

* Stirring ends*When program expires, TIME END displays. Once you press mode key or dialknob, it returns to standby status.

4-10 Magnetic Stirrer Thermo Scientific

Section 4Operation

Manual Stop DuringStirring (continued)

Monitoring OperationStatus During Stirring

Pressany key

Page 27: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

During set of either Timer mode or Program mode, it can be cancelled andreturns to standby mode in most cases.

(1) Rotate dial knob and choose EXIT.

(2) Press dial knob to return to standby status.

Magnetic Stirrer 4-11Thermo Scientific

Section 4Operation

Exit Mode

Page 28: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

Magnetic Stirrer 5-1Thermo Scientific

Section 5 Maintenance

Top plate

• Remove a contaminant by cleaning the unit with a wet soft cloth.

• Always keep the unit clean by wiping the unit with a dry soft cloth.

Plate cover

• Remove any contaminant by cleaning the unit frequently with a softcloth before and after using, otherwise the contaminant may bedifficult to remove.

• Always keep the unit clean, without any contaminants.

• Do not soak the product in water to clean.

ClassificationA period of checking time

Daily Weekly

General

Power cord

- Inspect power cord connection at unit and receptacle. •

- Inspect power cord for wear, cracks or cuts. •

Top plate and plate cover cleaning •

Magnetic stirrer

Controller display checking •

Controller function •

Motor on/off checking •

Motor speed checking •

Cleaning

Page 29: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

5-2 Magnetic Stirrer Thermo Scientific

Section 5Maintenance

(1) Unplug the instrument from the main power.

(2) Clean the instrument with a soft cloth neatly.

(3) Store in a dry place after packing.

To Store the Unit

Page 30: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

Section 6 Troubleshooting

Magnetic Stirrer 6-1Thermo Scientific

Electrical Trouble Causes Solution

The unit does not turn on

Incorrect electric powerCompare power source and voltage on the ID plate andmake sure they are the same. ID plate is found on theback of unit.

Power failure or circuit breaker shutsdown Find out the causes of power failure and recovery.

Main plug not seated properly. Check the electrical cord connection at the unit to ensureit is fully seated.

Socket / plug / main power line mightbe cut

If the socket / plug / main power line are cut, requestservice.

PCB has been damaged by reagent Request service

Fuse shorts inside product Request service

Room circuit breaker trips often when theunit is turned on or running.

Too many plugs connected at the sametime

1. Check the circuit breaker size as well as the voltageand current supplied to it.2. Check that several similar units are inserted together.If so, you should not use overly.

With the Power switch on, the main dis-play does not illuminate.

Power interruption Check for power interruption.

Main plug not seated properly. Check the electrical cord connection at the unit to ensureit is fully seated.

VFD display cracks VFD segment Fault Request service

Dial button doesn’t operate well Button problem Request service.

Dial button doesn’t work out

Controller problem Request service

Button damaged Request service

Page 31: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

6-2 Magnetic Stirrer Thermo Scientific

Section 6Troubleshooting

Symptoms During Operation Cause Trouble shooting

Magnetic bar is out of position

Too much solution (solvent) in flask. Reduce volume of solution (solvent)or increase RPM slowly.

High density of solution (solvent) in flask. Raise the rotation speed slowly untila proper speed is found.

Magnetic force of bar becoming weak. Replace magnetic bar.

Some kind of bumping soundfrom inside.

Trouble has occurred with the magnetic barinside machine Request service.

Dial knob doesn’t operate wellor doesn’t work out.

Restart error of electroststic capacity sen-sor.

Turn off switch and disconnectpower. Reconnect and restart unit.

In cases where the rotationspeed will not be controllednormally.

Using a program function

Check the functional set and anormal operation presence. Set thecontroller function according to useobjective.

BLDC motors and circuit troubles. Request service.

In case where magnet agitationstirring bar does not rotate

The low-speed rotation speed set whichdoes not hold in control scope

Use small size of stirring bar or raiserotation speed a little bit and fineproper rotation speed.

Page 32: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

Section 7 Accessories

Catalog No. . . . . . . . . . . . . . . . . . . . . . .Description88880145 . . . . Plate cover (White color, Silicon Ø170cm)88880146 . . . . Plate cover (White color, Silicon Ø220cm)

88880143 . . Support Rod (Ø12mm, 400mm, M10)

88880148 . . C-5, Clamp Holder (PP body, Ø12mm)

88880149 . . . . . . . . . .3 Prong Clamp ( 60mm grip)

Magnetic Stirrer 7-1Thermo Scientific

Page 33: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

Section 8 Specifications

Magnetic Stirrer 8-1Thermo Scientific

MODEL Magnetic Stirrer RT Touch-17 Magnetic Stirrer RT Touch-22

Technical data

Stirring Capacity (Liter, H2O) 4 5

Speed range (rpm) 30 ~ 2,000

Speed stability at 300 rpm ±5 rpm

Timer 1 min to 99 hr 59 min

Program control Two step repeatable pattern

Speed display VFD (Vacuum Fluorescent Display)

Motor rating input / output (W) 2.9 / 1.6

Magnetic bar (Ø x L, mm/inch), Max. 8 × 40 / 0.31 × 1.57 10 × 50 / 0.39 ×1.97

Load, Max (kg / lbs) 20 / 44.09 25 / 55.12

Top plateMaterial Polypropylene with non-slip plate cover

Dimension (mm/inch, Ø) 170 / 6.69 220 / 3.86

General data

Body material Polypropylene

Dimension (mm/inch, W x D x H) 210 x 280 x 72 / 8.27 x 11.02 x 2.82

260 x 360 x 72 / 10.24 x 14.17 x 2.82

Weight (kg / lbs) 1.35 / 2.98 1.75 / 3.86

Permissible ambient temperature (°C) +5 ~ 40

Permissible relative humidity (%) up to 80

Electrical requirements Free voltage and frequency (AC 100 ~ 240V, 50/60Hz)

Power consumption (W) 6

Motor Long life BLDC (Brushless Direct Current)

Control type Electronic speed control

Adjustment tool Touch key, adjustment knob

Safety Device Thermal Shutdown, current limit protection

Protection class acc. to DIN EN 60529 IP42

Page 34: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

8-2 Magnetic Stirrer Thermo Scientific

Section 8Specifications

Disposing of theProduct

* The upper specification could be changed in compliance with thequality and an efficiency improvement of the product.

* Speed range (rpm): The set point starts from 10rpm. With magneticbar according to the capacity of the reagent could be controlled below30rpm.

(1) Stirring capacity: Stirring capacity (liter) of the water (H2O) atmaximum speed (RPM).

(2) Speed range: maximum stirring speed range with maximum stirringcapacity and magnetic bar

(3) Magnetic bar: maximum magnetic bar size which does not disconnectat the maximum speed and capacity.

(4) Load Max. : Maximum load capacity of flask and solution (H2O) unitcan bear in normal circumstance.

(5) Protection class acc. to DIN EN 60529: water proof, vibration prooftest.

Dispose the unit with separating plastic mold, motor, and magnet.

Test Standard

Page 35: Operation Manual Magnetic Stirrer RT Touch Control Layout 1

Magnetic Stirrer 9-1Thermo Scientific

For the name of the authorized Thermo Scientific product dealer nearest you or any additional information, contact us:

North America: USA/Canada +1 866 984 3766 (866-9-Thermo) www.thermo.com

Europe: Austria +43 1 801 40 0, Belgium +32 2 482 30 30, France +33 2 2803 2180, Germany national toll free 08001-536 376, Germany international +49 6184 90 6940, Italy +39 02 02 95059 434-254-375, Netherlands +31 76 571 4440,Nordic/Baltic countries +358 9 329 100, Russia/CIS +7 (812) 703 42 15, Spain/Portugal +34 93 223 09 18, Switzerland+41 44 454 12 12, UK/Ireland +44 870 609 9203

Asia: China +86 21 6865 4588 or +86 10 8419 3588, India toll free 1800 22 8374, India +91 22 6716 2200, Japan +8145 453 9220, other Asian countries +852 2885 4613

Countries not listed: +49 6184 90 6940 or +33 2 2803 2180

THERMO FISHER SCIENTIFIC STANDARD PRODUCT WARRANTYThe Warranty Period starts two weeks from the date your equipment is shipped from our facility. This allows for shipping time so the warranty will gointo effect at approximately the same time your equipment is delivered. The warranty protection extends to any subsequent owner during the first yearwarranty period.

During the first two (2) years, component parts proven to be non-conforming in materials or workmanship will be repaired or replaced at Thermo'sexpense, labor included. Installation and calibration are not covered by this warranty agreement. The Technical Services Department must be contact-ed for warranty determination and direction prior to performance of any repairs. Expendable items, glass, filters and gaskets are excluded from thiswarranty.

Replacement or repair of components parts or equipment under this warranty shall not extend the warranty to either the equipment or to the compo-nent part beyond the original warranty period. The Technical Services Department must give prior approval for return of any components or equipment.At Thermo's option, all non-conforming parts must be returned to Thermo Fisher Scientific postage paid and replacement parts are shipped FOB desti-nation.

THIS WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, WHETHER WRITTEN, ORAL OR IMPLIED. NO WARRANTIESOF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL APPLY. Thermo shall not be liable for any indirect or consequentialdamages including, without limitation, damages relating to lost profits or loss of products.

Your local Thermo Sales Office is ready to help with comprehensive site preparation information before your equipment arrives. Printed instruction man-uals carefully detail equipment installation, operation and preventive maintenance.

If equipment service is required, please call your Technical Services Department at 1-800-438-4851 (USA and Canada) or 1-740-373-4763. We're readyto answer your questions on equipment warranty, operation, maintenance, service and special application. Outside the USA, contact your local dis-tributor for warranty information.

Rev. 0 9/13