20
HELMUT KÄMPKEN GMBH OPERATING MANUAL Operating manual for Steam Injectors / Mixing Nozzles

Operating manual for Steam Injectors / Mixing Nozzles€¦ · Steam Injectors / Mixing Nozzles were designed and built on the basis of a risk analysis and under consideration of all

  • Upload
    others

  • View
    17

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Operating manual for Steam Injectors / Mixing Nozzles€¦ · Steam Injectors / Mixing Nozzles were designed and built on the basis of a risk analysis and under consideration of all

HELMUT KÄMPKEN GMBH OPERATING MANUAL

Operating manualfor

Steam Injectors / Mixing Nozzles

Page 2: Operating manual for Steam Injectors / Mixing Nozzles€¦ · Steam Injectors / Mixing Nozzles were designed and built on the basis of a risk analysis and under consideration of all

HELMUT KÄMPKEN GMBH PRODUCT DESCRIPTION

2

1. Product Description1.1 Prescribed use

Steam HeatersSteam Injectors are often used to heat water or other liquid media in the production cycle.These Steam Heaters usually work in closed circuits, in tanks and other pipelines.Heating processes can find place in only one step or in closed circuits with a defined Start-and Final Temperature.

Pipeline mountingSteam Injectors can be mounted in pipelines with looses or fixed flanges according to DINor ANSI-Standards.

Mounting inside of a vesselKaempken Steam Injectors also can be installed below liquid/water level to directly heatwater or other water compatible liquid media inside containers, vessels or tanks.The steam will be quietly induced into the liquid and completely condensed.The suction effect of the injector causes a medium flow inside the vessel and this causesa uniform temperature inside the container.

Content: Page1. Product Description 2

1.1 Prescribed use 21.2 Structure 31.3 Description of functions 41.4 Technical specifications 5

2. EC-Declaration of conformity 73. General safety instructions 8

3.1 Operator's duty of care 83.2 Explanation of the safety symbols used 103.3 Basic safety measures 113.4 Requirements of operating personnel 13

4. Special types of danger 145. Transport 166. Setting up the machine 177. Putting the machine into operation 188. Operating the machine 199. Supplementary informations 20

Page 3: Operating manual for Steam Injectors / Mixing Nozzles€¦ · Steam Injectors / Mixing Nozzles were designed and built on the basis of a risk analysis and under consideration of all

HELMUT KÄMPKEN GMBH PRODUCT DESCRIPTION

3

HotwaterstationA one time passing waterflow with a large ∆t can be heated with these stations. To receivean even steam pressure admission several steam injectors are arranged in series and arecontrolled by a thermostatic control valve.

Range of application of Steam Injectors / Mixing Nozzles- Heating of liquid media by means of steam- Recooling of superheated steam- Mixing of different media- Heating of Suspensions and Emulsions- Heating of pulp for paper industries- Feeding of gases (CO2)

1.2 StructureKaempken steam heaters accomplish the requirements of silently feeding steam into themedium yet achieving maximum heat transmission.The medium is hereby accelerated in a venturipipe. A cone shaped counterpiece forms anannular slot between cone and the outside of the nozzle's diameter.Steam is tangentially fed into the outer jacket of the housing and is able to escape throughthe annular slot. In doing so the circular steam ray/annular jet covers the to be heatedmedium and condenses the same.The injectors are particularly advantageous because of their mounting size and thus theycan be installed inside any vessel, tank or container.The Injectors for pipeline mounting are fitted with loose or fixed flanges in DIN or ANSIstandard.They are manufactured in the sizes DN 15 (½") until DN 300 (12") on the water side.The standard execution is PN 16 (until DN 150 or 6") or PN 10 = 150# (from DN 200, 8" tillDN 300, 12"). Higher pressure groups like PN 40 or 300# are also available.The injectors for vessel mounting are fitted with a steam flange or pipe thread.

RKE 50/25 in clamping executionfor pipeline mounting

RFF 80/40 with fixed flangesfor pipeline mounting

IGE 65/25 with threaded standpipefor vessel mounting

Page 4: Operating manual for Steam Injectors / Mixing Nozzles€¦ · Steam Injectors / Mixing Nozzles were designed and built on the basis of a risk analysis and under consideration of all

HELMUT KÄMPKEN GMBH PRODUCT DESCRIPTION

4

1.3 Description of functions

Steam Injectors / Mixing NozzlesThe medium to be heated is accelerated in a venturi nozzle. A tapered counterpiece is ofsuch embodiment that an annular slot is formed between the cone and the outer nozzlediameter.The steam is fed tangentially into the outer jacket of the housing and escapes through theannular slot. At the stage an annular jet covers the product and condenses the same.The condensation still finds place in the steam injector and not in the following pipeline.The steam quantity can be controlled from 0 - 100%, because the injector is able to suckin also a very small quantity of steam.On the waterside the control range is restricted.A velocity of 0,8 - max. 3,0 m/sec is necessairy.We propose to choose the size of the steam injectors in that way that the velocity is 1,5m/sec.

Recooling of superheated steamIn case of cooling superheated steam, the steam flows through the venturi nozzle and thewater will be fed by the tangential standpipe.By a temperature control unit the water quantity can be controlled exactly.

Page 5: Operating manual for Steam Injectors / Mixing Nozzles€¦ · Steam Injectors / Mixing Nozzles were designed and built on the basis of a risk analysis and under consideration of all

HELMUT KÄMPKEN GMBH PRODUCT DESCRIPTION

5

1.4 Technical specifications

Page 6: Operating manual for Steam Injectors / Mixing Nozzles€¦ · Steam Injectors / Mixing Nozzles were designed and built on the basis of a risk analysis and under consideration of all

HELMUT KÄMPKEN GMBH PRODUCT DESCRIPTION

6

Page 7: Operating manual for Steam Injectors / Mixing Nozzles€¦ · Steam Injectors / Mixing Nozzles were designed and built on the basis of a risk analysis and under consideration of all

HELMUT KÄMPKEN GMBH PRODUCT DESCRIPTION

7

2 EC Declaration of conformityin accordance with EG-Directive 97/23/EG from May 29, 1997

The manufacturer: Helmut Kämpken GmbHKupferfeld 7D-53819 Neunkirchen-Seelscheid

hereby declares that the productsdescribed below

Steam injection nozzles models:

- RKE, RFF, RLF, IGE, ILF, IFF

- Nominal bore from DN 15(½") to DN 300

(12")

- Design Pressure PN 16 (up to DN 150, 6")

- Design Pressure PN 10 (from DN 200, 8")

complies with the health and safetyprotection requirements of the followingEC directives:

EG-Directive 97/23/EG from May 29, 1997

- Category I

- Modul A, A1

Harmonised standards used:

National standards and technical specifications used:

AD 2000, AD-HP 0, AD-B, AD-W AD-code of practice

This declaration of conformity is void if changes are made to the construction of themachine which affect the technical specifications and prescribed use as indicated in theoperator's manual, i.e. which essentially change the machine!

Neunkirchen-Seelscheid, January 01, 2001 (Signature)

Marcel Fischer, General Manager

Page 8: Operating manual for Steam Injectors / Mixing Nozzles€¦ · Steam Injectors / Mixing Nozzles were designed and built on the basis of a risk analysis and under consideration of all

HELMUT KÄMPKEN GMBH GENERAL SAFETY INSTRUCTIONS

8

3 General safety instructions

3.1 Operator’s duty of care

Steam Injectors / Mixing Nozzles were designed and built on the basis of a risk analysisand under consideration of all relevant harmonised standards as well as further nationalstandards and technical specifications. The machine thus conforms to the current level oftechnology and guarantees the highest possible degree of safety.

This level of safety can only be achieved in practice if all necessary measures areobserved in dealing with the machine. It is therefore part of the duty of care of themachine's operator to plan these measures and check that they are executed correctly.

In particular the operator must ensure that

- the components are used only as prescribed (cf. chapter "Product description")

- the components are not be used with a higher pressure than the design pressure.We propose to use pressure relief valves.

- the components are not to be used with a higher temperature than the designtemperature. The temperature should be controlled constantly by the operator.If it is possible that persons could be in contact with the heated water or penetratingsteam we propose to install safety temperature control valves.

- the components are only used with the defined fluids.

- the flow direction is in compliance with the stipulated flow direction which is markedon the housing

- the tightness of the components will be controlled at regular intervals especially if verycorrosive or abrasive media will be used.

- occuring vibrations or oscillations, caused by unfavourable operating conditions, willbe eliminated by the use of compensator pipes or tubes.

- the components are operated only in a fault-free, operational condition and inparticular the safety devices are regularly checked to ensure that they function asstipulated

- the components are not exposed to excessive loads (forces and moments from thepipeline). According to the installation conditions the distance of the supports and theflexibility of the pipeline should be calculated.

- the flange connections are located at a clearly visible place and within easy reach.

- connecting pipelines are fitted with the correct counterflanges with the same nominal

Page 9: Operating manual for Steam Injectors / Mixing Nozzles€¦ · Steam Injectors / Mixing Nozzles were designed and built on the basis of a risk analysis and under consideration of all

HELMUT KÄMPKEN GMBH GENERAL SAFETY INSTRUCTIONS

9

bore and pressure group. All Screws/Nuts and Gaskets must be mounted.

- supports are calculated adequate

- there are no unforeseen additional forces

- a safely pressure draining off is possible and will be proceeded. During the productionit is prohibited to loosen any bolted connection.

- the surface of the components is insulated to invoid any contact with hot parts.

- any necessary protective equipment or apparel for the operating, maintenance andrepair personnel is available and is used

- the operating manual is always legible and is available in full at the machine's location

- the machine is operated, maintained and repaired only by sufficiently qualified andauthorised personnel

- these personnel are regularly instructed in all matters relating to occupational safetyand environmental protection and are familiar with the operating manual and inparticular the safety instructions it contains

- all safety instructions and warnings on the machine are visible and legible and arenot removed.

Page 10: Operating manual for Steam Injectors / Mixing Nozzles€¦ · Steam Injectors / Mixing Nozzles were designed and built on the basis of a risk analysis and under consideration of all

HELMUT KÄMPKEN GMBH GENERAL SAFETY INSTRUCTIONS

10

3.2 Explanation of the safety symbols usedThe safety symbols together with accompanying text must warn of residual dangers whichcannot be avoided when using the machine. These residual dangers relate to- persons- the machine- other property and objects- the environment.

The present operating manual contains the following safety symbols.

These symbols indicate above all danger to the life and health of persons, but danger tothe machine, property or the environment is also possible.

Use Eye - Protection

Attention ! Hot surfaceAttention ! Hot Liquidsand steam

Irritant

Page 11: Operating manual for Steam Injectors / Mixing Nozzles€¦ · Steam Injectors / Mixing Nozzles were designed and built on the basis of a risk analysis and under consideration of all

HELMUT KÄMPKEN GMBH GENERAL SAFETY INSTRUCTIONS

11

3.3 Basic safety measures

Keeping information available:

This operating manual must be kept near the machine. It must be ensured that all personswho have to perform activities on the machine can consult the operating manual at anytime. In addition to the operating manual, job control statements within the meaning of theHealth and Safety at Work Act and the regulation governing the use of tools andequipment must also be provided.

All labels on the machine which display safety and operating instructions must always bekept legible. Worn or damaged labels must be replaced immediately.

Before starting:

Familiarise yourself sufficiently with- the machine's operating and control elements- the machine's fittings- how the machine works- the immediate environment of the machine

Installation

- During the installation all steam and water piping must be closed with the help of shut-off valves (Danger of burning)

Use Eye - ProtectionAttention ! HotLiquids and steam

Page 12: Operating manual for Steam Injectors / Mixing Nozzles€¦ · Steam Injectors / Mixing Nozzles were designed and built on the basis of a risk analysis and under consideration of all

HELMUT KÄMPKEN GMBH PRODUCT DESCRIPTION

12

Before every starting the following procedures have to be carried out:- The tightness of the installation has to be controlled during the start-up- The valves of the water should be opened before the steam valve- Check to make sure that all safety devices are fitted and functioning.- Check the machine for visible damage; any defects found must be corrected

immediately or reported to the supervisor - the machine may only be operated if it isfree of faults.

- Make sure that only authorised persons remain within the operating area of themachine and that no other persons are endangered when the machine is started up.

In normal operation:

While the machine is in operation, no safety devices may be removed or deactivated.

The operating personnel must make sure that no unauthorised persons remain within theoperating area of the machine.

At least once a week, the following checking activities must be performed:- The tightness of the installation has to be controlled- The function of safety devices has to be controlled- The injector must be controlled relating to defects

Page 13: Operating manual for Steam Injectors / Mixing Nozzles€¦ · Steam Injectors / Mixing Nozzles were designed and built on the basis of a risk analysis and under consideration of all

HELMUT KÄMPKEN GMBH PRODUCT DESCRIPTION

13

Changes to the machine:

For safety reasons, no unauthorised changes may be made to the machine - this alsoapplies to welding work on bearing parts.

All planned changes must be authorised in writing by the company Helmut KämpkenGmbH. If any changes or repairs will be done by unauthorized personnel all warrantiesare invalid.

Parts and special fittings which were not supplied by us are also not approved by us foruse in/on the machine.

3.4 Requirements of operating personnel

The machine may only be operated by persons who have been specially trained, briefedand authorised. These persons must be familiar with the operating manual and act inaccordance with it. The respective areas of authority of the operating personnel must beclearly defined.

All control and safety devices must be operated only by persons who have been suitablyinstructed.

Page 14: Operating manual for Steam Injectors / Mixing Nozzles€¦ · Steam Injectors / Mixing Nozzles were designed and built on the basis of a risk analysis and under consideration of all

HELMUT KÄMPKEN GMBH GENERAL SAFETY INSTRUCTIONS

14

4. Special types of danger

Thermal danger:

When working on Steam Injectors there is a risk of- burning through contact with steam and hot product

- burning through contact with hot surfaces

Attention ! HotLiquids and steam

Attention ! Hot surface

Page 15: Operating manual for Steam Injectors / Mixing Nozzles€¦ · Steam Injectors / Mixing Nozzles were designed and built on the basis of a risk analysis and under consideration of all

HELMUT KÄMPKEN GMBH GENERAL SAFETY INSTRUCTIONS

15

Danger from processing materials and other substances:

While the machine is running, dangerous waste gases, steam, dust, vapours, liquids, ...can escape. Adequate ventilation or filtering must therefore be guaranteed.

As a special protective device against the chemicals used, a rinsing facility for the eyesmust be installed.

When working on Steam Injectors there is a risk of- having contact with irritant or agressive product

Danger from noise:

The continuous sound pressure level at the workplaces of the operating personnel is .......70 - 85 dB(A).

Depending on the local conditions, higher sound pressure levels can occur, which cancause deafness, loss of balance or diminished alertness. In this case the operatingpersonnel must be provided with adequate personal protective equipment.

Remember that while the machine is running voice communication and acoustic signals,e.g. hooting of vehicles, are impaired.

Observe the noise provisions in the job control statement for your workplace and use thepersonal protective equipment prescribed.

Irritant

Use Ear - Protection

Page 16: Operating manual for Steam Injectors / Mixing Nozzles€¦ · Steam Injectors / Mixing Nozzles were designed and built on the basis of a risk analysis and under consideration of all

HELMUT KÄMPKEN GMBH TRANSPORT

16

5. TransportWatch out for the following special dangers when transporting the machine:

- Protruding sharp edges can cause cuts.

- Suspended loads can fall, thus endangering lives. Never stand under suspended loads!

- Use only the original packaging.

- Read the chapter "General safety instructions".

- The surfaces of the Injectors always have to be covered with suitable caps.

Page 17: Operating manual for Steam Injectors / Mixing Nozzles€¦ · Steam Injectors / Mixing Nozzles were designed and built on the basis of a risk analysis and under consideration of all

HELMUT KÄMPKEN GMBH SETTING UP

17

6. Setting up the machine

When setting up the Steam Injectors, you must observe the following safety instructions inorder to avoid lethal injury, damage to the machine and other material damage.

- The steps involved in setting up the machine - assembly and installation - may only becarried out by qualified persons taking into account the safety instructions.

- Before you begin setting up the machine, it must be checked for any damages incurredduring transport.

- Shut - Off Valves of water and steam must be closed- The pipelines have to be discharged and the flanges must be closed with the help of

gaskets.- The Injector has to be installed in a correct flow path and with the required sealings.- Any installation position of the injector can be choosed.- We propose to install the injectors with zinc-coated screws. Using stainless steel

screws can lead to grinding of the material.- We propose the installation of a non-return valve behind the steam valve.- All steam pipelines should be insulated to avoid contact with the hot pipeline.- Read also the chapter "General safety instructions".

Page 18: Operating manual for Steam Injectors / Mixing Nozzles€¦ · Steam Injectors / Mixing Nozzles were designed and built on the basis of a risk analysis and under consideration of all

HELMUT KÄMPKEN GMBH OPERATING

18

7. Putting the machine into operation

When putting the machine into operation, you must observe the following safetyinstructions in order to avoid lethal injury, damage to the machine and other materialdamage.

The machine may only be put into operation by qualified persons taking into account thesafety instructions.

- Make sure that only authorised persons remain in the machine's operating area andthat no other persons are endangered when the machine is put into operation.

- Before starting the machine for the first time, make sure that all tools and foreign partshave been removed from the machine.

- Read the chapter "General safety instructions".- Generaly we propose:- Shut - Off Valves of water and steam must be closed- The tightness of the installation has to be controlled during the start-up- The valves of the water should be opened before the steam valve

Page 19: Operating manual for Steam Injectors / Mixing Nozzles€¦ · Steam Injectors / Mixing Nozzles were designed and built on the basis of a risk analysis and under consideration of all

HELMUT KÄMPKEN GMBH OPERATING

19

8. Operating the machine

The Operating of steam Injectors will normaly be performed by the central control room ofthe company so that specific operation instructions of the complete installation have to beobserved.

When operating the machine, you must observe the following safety instructions in orderto avoid lethal injury, damage to the machine and other material damage.

- The machine may only be used as prescribed.

- Before starting the machine, check the tightness of the installation.

- Read the chapter "General safety instructions".

Watch out for the following special dangers while operating and during normal running ofthe machine:

- Using the machine for applications other than those for which it is intended can causelethal injuries to persons and damage to the machine.

- Negligent use of the personal protective equipment can lead to severe bodily injuries.

- Incorrect behaviour in the event of a malfunction can lead to serious personal andmaterial damage. You must therefore familiarise yourself with the provisions for cases ofmalfunction.

Page 20: Operating manual for Steam Injectors / Mixing Nozzles€¦ · Steam Injectors / Mixing Nozzles were designed and built on the basis of a risk analysis and under consideration of all

FÜGEN SIE IHR FIRMENLOGO EIN! SUPPLEMENTARY INFORMATIONS

20

9. Supplementary informations

Do you have any questions or requests? We will be glad to help you.

Our company address is:

Helmut Kämpken GmbHKupferfeld 7D-53819 Neunkirchen-SeelscheidGermany

You can reach our central customer service department underTel.: +49 (0)2247 / 6534Fax: +49 (0)2247 / 74241

Here you can also get help in finding the right specialist to answer your question.

For questions on Steam Injectors / Mixing Nozzles you will get the best help fromMr. Fischer or Mr. BaumgartenTel.: +49 (0)2247 / 6534Fax: +49 (0)2247 / 74241E-mail: [email protected] can also visit our homepage:http://www.kaempken.de

Here you will find current informations concerning Steam Injectors / Mixing Nozzles