Operating Instructions Air Conditioner
Model No.
OUTDOOR UNIT
Single Split (Single-phase)Type PZH2U-160PZH2R5Single Split (3-phase)Type PZH2U-160PZH2R8U-180PZH2R8U-200PZH2R8U-224PZH2R8
●ConnectableindoorunitlineupThisbookletistheoperatinginstructionsforoutdoorunit.Regardingtheindoorunit,seetheoperatinginstructionssuppliedwiththeindoorunit.
INDOOR UNIT
DuctedHighStaticPressureDucted
Panasonic Corporation1006Kadoma,KadomaCity,Osaka,Japan ACXF55-23660
Beforeoperatingtheunit,readtheseoperatinginstructionsthoroughlyandkeepthemforfuturereference.
OI_00_310578_en.indb 1 2018/12/19 9:57:11
2
z Safety Precautions........................................................... 2 z Precautions for Use......................................................... 5 z Names of Parts................................................................. 6
z Specifications................................................................... 7•Outdoor unit...................................................................7
Contents
Thank you for purchasing this Panasonic product.This product is a commercial air conditioner outdoor unit.Installation Instructions attached.
Product InformationIfyouhaveproblemsorquestionsconcerningyourAirConditioner,youwillneedthefollowinginformation.Modelandserialnumbersareonthenameplate.
ModelNo.
SerialNo.
Dateofpurchase
Dealer’saddress
Phonenumber
Safety PrecautionsThefollowingsymbolsusedinthismanual,alertyoutopotentiallydangerousconditionstousers,servicepersonnelortheappliance:
WARNINGThissymbolreferstoahazardorunsafepracticewhichcanresultinseverepersonalinjuryordeath.
CAUTIONThissymbolreferstoahazardorunsafepracticewhichcanresultinpersonalinjuryorproductorpropertydamage.
Prohibitedmatters Matterstobeobserved
•ReadtheseOperatingInstructionscarefullybeforeusingthisairconditioner.Ifyoustillhaveanydifficultiesorproblems,consultyourdealerforhelp.
•Thisairconditionerisdesignedtogiveyoucomfortableroomconditions.UsethisonlyforitsintendedpurposeasdescribedintheseOperatingInstructions.
Confirmtoauthorizeddealerorspecialistonusageofspecifiedrefrigeranttype.Usingofrefrigerantotherthanthespecifiedtypemaycauseproductdamage,burstandinjuryetc.Thisairconditionerhasnoventilatorforintakingfreshairfromoutdoors.Youmustopendoorsorwindowsfrequentlywhenyouusegasoroilheatingappliancesinthesameroom,whichconsumealotofoxygenfromtheair.Otherwisethereisariskofsuffocationinanextremecase.Neveruseorstoregasolineorotherflammablevapororliquidneartheairconditioner—itisverydangerous.Donotusethisapplianceinapotentiallyexplosiveatmosphere.Nevertouchtheunitwithwethands.Donotinsertyourfingersorotherobjectsintotheairconditionerindoororoutdoorunit,rotatingpartsmaycauseinjury.
WARNING
WARNING
This symbol shows that this equipment uses a flammable refrigerant. If the refrigerant is leaked, together with an external ignition source, there is a possibility of ignition.
CAUTIONThis symbol shows type of flammable refrigerant contained in the system.
CAUTION
This symbol shows that a service personnel should be handling this equipment with reference to the Technical Manual.
CAUTIONThis symbol shows that there is information included in the Operating Instructions and/or Installation Instructions.
Important Information Regarding The Refrigerant UsedThisproductcontainsfluorinatedgreenhousegases.Donotventgasesintotheatmosphere.Refrigeranttype:R32GWP(1)value:675(1)GWP=globalwarmingpotentialPeriodicalinspectionsforrefrigerantleaksmayberequireddependingonEuropeanorlocallegislation.Pleasecontactyourlocaldealerformoreinformation.
OI_00_310578_en.indb 2 2018/12/19 9:57:11
3
Iftherefrigerantcomesincontactwithaflame,itproducesatoxicgas.Forsafety,besuretoturntheairconditioneroffandalsotodisconnectthepowerbeforecleaningorservicing.Pulloffthepowerplugfromareceptacle,orswitchoffthebreaker,orswitchoffthepowerdisconnectingmeantoisolatetheairconditionerfromthemainpowersupplyincaseofemergency.Disposeofaccordingtonationaland/orlocallegislation.Thisproductmustnotbemodifiedordisassembledunderanycircumstances.Modifiedordisassembledunitmaycausefire,electricshockorinjury.Donotcleaninsidetheindoorandoutdoorunitsbyusers.Engageauthorizeddealerorspecialistforcleaning.Incaseofmalfunctionofthisappliance,donotrepairbyyourself.Contactthesalesdealerorservicedealerforarepairanddisposal.
Provideapoweroutlettobeusedexclusivelyforeachunit,andapowersupplydisconnect,EarthLeakageCircuitBreaker(ELCB)orResidualCurrentDevice(RCD)forovercurrentprotectionshouldbeprovidedintheexclusiveline.Provideapoweroutletexclusivelyforeachunit,andfulldisconnectionmeanshavingacontactseparationinallpolesmustbeincorporatedinthefixedwiringinaccordancewiththewiringrules.Topreventpossiblehazardsfrominsulationfailure,theunitmustbegrounded.
Theapplianceshallbestoredinaroomwithoutcontinuouslyoperatingignitionsources(forexample:openflames,anoperatinggasapplianceoranoperatingelectricheater).Beawarethatrefrigerantsmaynotcontainanodour.Anunventilatedareawheretheapplianceusingflammablerefrigerantsisinstalledshallbesoconstructedthatshouldanyrefrigerantleak,itwillnotstagnatesoastocreateafireorexplosionhazard.Theapplianceshallbestoredinawell-ventilatedareawheretheroomsizecorrespondstotheroomareaasspecifiedforoperation.
Aftertheunitisinstalled,neverfailtoasktheinstallerforthefloorspaceoftheroomwheretheunitisinstalledandtherefrigerantchargeamount.Incasetheunitortheroomdividerischanged,neverfailtoconsultthesalesdealerorservicedealer.Donotusemeanstoacceleratethedefrostingprocessortoclean,otherthanthoserecommendedbythemanufacturer.Donotpierceorburn.Incasesthatrequiremechanicalventilation,ventilationopeningsshallbekeptclearofobstruction.
WARNINGDonotusemodifiedcord,jointcord,extensioncordorunspecifiedcordtopreventoverheatingandfire.
OI_00_310578_en.indb 3 2018/12/19 9:57:12
4
WARNING
Stopusingtheproductwhenanyabnormality/failureoccursanddisconnectthepowerplugorturnoffthepowerswitchandbreaker.(Riskofsmoke/fire/electricshock)Examplesofabnormality/failure:•TheELCBtripsfrequently.•Theproductsometimesdoesnotstartwhenturnedon.•Thepowerissometimesdisconnectedwhenthecordismoved.•Burntodororabnormalnoiseisdetectedduringoperation.•Thebodyisdeformedorabnormallyhot.•Waterleaksfromtheindoorunit.•Powercordorplugbecomesabnormallyhot.•Fanspeedcannotbecontrolled.•Theunitstopsrunningimmediatelyevenifitisswitchedonforoperation.•Thefandoesnotstopeveniftheoperationisstopped.Contactimmediatelyyourlocaldealerformaintenance/repair.
Donotsitorstepontheunit.Youmayfalldownaccidentally.
Thisapplianceisintendedtobeusedbyexpertortrainedusersinshops,inlightindustryandonfarms,orforcommercialusebylaypersons.Thisapplianceisnotintendedforusebypersons(includingchildren)withreducedphysical,sensoryormentalcapabilities,orlackofexperienceandknowledge,unlesstheyhavebeengivensupervisionorinstructionconcerninguseoftheappliancebyapersonresponsiblefortheirsafety.Childrenshouldbesupervisedtoensurethattheydonotplaywiththeappliance.Keepthefirealarmandtheairoutletatleast1.5mawayfromtheunit.Donotcoolorheattheroomtoomuchifbabiesorinvalidsarepresent.Donotturntheairconditioneronandofffromthepowermainsswitch.UsetheON/OFFoperationbutton.Donotstickanythingintotheairoutletoftheoutdoorunit.Thisisdangerousbecausethefanisrotatingathighspeed.Donottouchtheairinletorthesharpaluminumfinsoftheoutdoorunit.Youmaygetinjured.DonotstickanyobjectintotheFANCASE.Youmaybeinjuredandtheunitmaybedamaged.
CAUTION
•Theapplianceshallbestoredsoastopreventmechanicaldamagefromoccurring.•Thecompressormayoccasionallystopduringthunderstorms.Thisisnotamechanicalfailure.Theunitautomaticallyrecoversafterafewminutes.
NOTICE
Theapplianceshallbestoredinaroomwithoutcontinuouslyoperatingopenflames(forexample:anoperatinggasappliance)andignitionsources(forexample:anoperatingelectricheater).
OI_00_310578_en.indb 4 2018/12/19 9:57:12
5
Precautions for UseInstallation
z ThisairconditionermustbeinstalledproperlybyqualifiedinstallationtechniciansinaccordancewiththeInstallationInstructionsprovidedwiththeunit. z Beforeinstallation,checkthatthevoltageoftheelectricsupplyinyourhomeorofficeisthesameasthevoltageshownonthenameplate.
WARNINGAvoid the following locations for installation. z Locationswheresmokeorcombustiblegasexists.Alsolocationsofextremelyhightemperaturesuchasagreenhouse. z Locationswhereexcessivelyhighheat-generatingobjectsareplaced.
Attention:
z Avoidinstallingtheoutdoorunitwheresaltyseawatercansplashdirectlyontoitorinsulphurousairnearaspa.(Toprotecttheairconditionerfromheavycorrosion)
Wiring z Allwiringmustconformtothelocalelectricalcodes.(Consultyourdealeroraqualifiedelectricianfordetails.) z Eachunitmustbeproperlygroundedwithaground(orearth)wireorthroughthesupplywiring. zWiringmustbedonebyaqualifiedelectrician.
Operation PreparationTurn the power mains on 5 hours before the start of operation.(Forwarm-up) z LeavethepowermainsONforcontinuoususe.
ON
NOTE
Pulloffthepowerplugfromareceptacle,orswitchoffthebreaker,orswitchoffthepowerdisconnectingmeantoisolatetheairconditionerfromthemainpowersupplywhennotinuseforalongtime.
Information for Users on Collection and Disposal of Old Equipment and Used Batteries
[Information on Disposal in other Countries outside the European Union] ThesesymbolsareonlyvalidintheEuropeanUnion.Ifyouwishtodiscardtheseitems,pleasecontactyourlocalauthoritiesordealerandaskforthecorrectmethodofdisposal.
Pb
Note for the battery symbol (bottom two symbol examples):Thissymbolmightbeusedincombinationwithachemicalsymbol.InthiscaseitcomplieswiththerequirementsetbytheDirectiveforthechemicalinvolved.
OI_00_310578_en.indb 5 2018/12/19 9:57:12
6
Names of Parts
�Operation RefertotheOperatingInstructionsattachedtotheoptionalRemoteController.
�AdjustingAirflowDirectionRefertotheOperatingInstructionsattachedtotheindoorunitandoptionalRemoteController.
�Maintenance RefertotheOperatingInstructionsattachedtotheindoorunit.
�Troubleshooting RefertotheOperatingInstructionsattachedtotheindoorunit.
Optional
OUTDOOR UNIT
Single Split (TypePZH2)
Airintake(rear,leftside)
Airoutlet
Drainport(bottom) Anchorhole
ModelNo.CZ-RTC5B
Forallindoorunits
Wireless Remote Controller
A
ModelNo.CZ-RTC4
Forallindoorunits
Timer Remote Controller
ReadtheOperatingInstructionsincludedwiththeRemoteController.
High-spec Wired Remote Controller
Optional
ModelNo.CZ-RWS3
(InfraredRemoteController)
OI_00_310578_en.indb 6 2018/12/19 9:57:13
7
Single Split Outdoor Unit (R32)Model Name U-160PZH2R5 U-160PZH2R8 U-180PZH2R8 U-200PZH2R8 U-224PZH2R8
Power source 230-240V~50Hz 400-415V3N~50Hz
Cooling capacitykW 16.0 16.0 18.0 20.0 22.4
BTU/h 54,600 54,600 61,400 68,200 76,400
Heating capacitykW 18.0 18.0 20.0 22.4 25.0
BTU/h 61,400 61,400 68,200 76,400 85,300
Sound Pressure level(Cooling/Heating) dB(A) 58/60 58/60 58/60 58/62 58/62
Sound Power level(Cooling/Heating) dB(A) 76/78 76/78 76/78 77/81 77/81
Unit Dimensions(H×W×D) mm 1,500×980×370 1,500×980×370 1,500×980×370 1,500×980×370 1,500×980×370
Net weight kg 117 115 115 128 128
Operation condition temperature range•Coolingmode:-15°C~46°CDB•Heatingmode:-20°C~24°CDB
RatedconditionsCooling:Indoorintakeairtemp.27°CDB/19°CWB.Outdoorintakeairtemp.35°CDB.Heating:Indoorintakeairtemp.20°CDB.Outdoorintakeairtemp.7°CDB/6°CWB.
Outdoor unit
Specifications
OI_00_310578_en.indb 7 2018/12/19 9:57:13
Panasonic Corporationhttp://www.panasonic.comPrintedinMalaysia
©PanasonicCorporation2018ACXF55-23660
DC1218-0
OI_00_310578_en.indb 8 2018/12/19 9:57:13