  • NetworkingDistributor racks, based on Rittal Data Rack

    B

    5.1

    Net

    wo

    rkin

    g

    708 Rittal Catalogue 31/IT solutions

    T1

    H1

    B1

    H2

    B2

    T2

    Supply includes:1 torsionally stiff section frame welded from 2 mm sheet steel with 482.6 mm(19) punchings, spray finished in RAL 7035, trim in RAL 5018, 1 stable base/plinth of folded sheet steel and integral die-cast zinc feet (RAL 5018) with the option of floor anchoring, includ-ing mounting accessories. Alternatively, levelling feet (DK 7493.000) or castors (DK 7495.000) may be fitted.

    Available on request: Metric (535 mm) version Side rails Special versions and special

    sizes

    Load capacity: max. 150 kg/level

    Property rights: German registered design M 9201859German patent no. 4207282

    Detailed drawing, available on the Internet.

    Accesories Page 832 Monitoring Page 762 19 installation system Page 1010 Patch panels Page 1021

    U Packs of 31 36 40 45 PageWidth (B1) in mm 550 550 550 550Height (H1) in mm 1499.5 1721.8 1899.5 2121.8Depth (T1) in mm 750 750 750 750Clearance width (B2) mm 450 450 450 450

    Clearance height (H2) mm 1381.5 1603.8 1781.5 2003.8

    Distance from the second mounting level (T2) mm1) min. 150 max. 350 min. 150 max. 350 min. 150 max. 350 min. 150 max. 350

    U x 44.45 mm = 1377.95 1600.2 1778 2000.25

    Model No. DK 7391.000 7396.000 7400.000 7445.000AccessoriesSecond mounting level1) 1 7296.000 7297.000 7298.000 7299.000 709

    Baying clamp 3 7494.000 7494.000 7494.000 7494.000 709

    Levelling feet 4 7493.000 7493.000 7493.000 7493.000 710

    Cable duct 1 7827.333 7827.338 7827.342 7827.347 987

    C rails, 482.6 mm (19) 6 7016.100 7016.100 7016.100 7016.100 992 Cable clamp rail, 482.6 mm (19) 6 7016.110 7016.110 7016.110 7016.110 992 Cable clamp strap D = 250 mm 6 7016.120 7016.120 7016.120 7016.120 992

    Twin castors 4 7495.000 7495.000 7495.000 7495.000 848

    Depth stays 2 7401.000 7401.000 7401.000 7401.000 710

    Component shelf 2 U for one pair of mounting angles D = 250 mm 1 7119.250 7119.250 7119.250 7119.250 948

    Component shelf 2 U for one pair of mounting angles D = 400 mm 1 7119.400 7119.400 7119.400 7119.400 948

    Component shelf 2 U for one level D = 300 mm3) 1 7148.035 7148.035 7148.035 7148.035 946

    Drawer 2 U 1 7281.035 7281.035 7281.035 7281.035 1051

    Component shelf D = 300 mm2) 3) 1 7143.035 7143.035 7143.035 7143.035 944

    Component shelf D = 400 mm2) 3) 1 7144.035 7144.035 7144.035 7144.035 944

    Component shelf D = 500 mm2) 3) 1 7145.035 7145.035 7145.035 7145.035 944

    Slide rails D max. < 190 mm 10 1962.200 1962.200 1962.200 1962.200 999

    Slide rails D max. > 190 mm 10 1963.200 1963.200 1963.200 1963.200 999

    Slide rails for pairs of mounting angles1) 2 7402.000 7402.000 7402.000 7402.000 710 1) Second mounting level may be positioned on a 50 mm pitch pattern.2) A second pair of mounting angles is required for assembly.3) Stationary installation or full withdrawal, telescopic slides see page 951.

  • NetworkingAcessories for Rittal Data Rack

    B

    5.1N

    etw

    ork

    ing

    709Rittal Catalogue 31/IT solutions

    Second mounting levelIn order to accommodate 482.6 mm (19) net-work components or for the attachment of compo-nent shelves, slide rails and telescopic rails. The mounting level may be positioned on a 50 mm pitch pattern.Minimum distance between levels 150 mm,Maximum distance between levels 350 mm.

    Material:Sheet steel, 2 mm

    Colour:RAL 7035

    Supply includes:1 torsionally stiff section frame including assem-bly parts. 482.6 mm (19) punched profile at the front, hole centre distance 465 (470 mm at the rear), tailored to the attachment of patch panels and cable routing rails.

    Detailed drawing, can be found on the Internet.

    50 mm pitch patternmin. 150 max. 350

    U Model No. DK31 7296.00036 7297.00040 7298.00045 7299.000

    Baying connectorFor assembling rows of distributor frames, or for cable routing between data racks.

    Technical specifications:Length: 53 mm

    Colour:RAL 7035

    Packs of Model No. DK3 7494.000

    Roof plate for cable routingFor optimised use of the Data Rack as a corridor distributor or cable management rack. By moving the guide plates, the individual cableways can be separately sized, thus enabling structured cable routing in data highways, even in the roof area. On all Data Racks, the roof plate can be attached with two mounting levels and a distance between the levels of 350 mm.

    Material:Sheet steel, spray-finished

    Colour:RAL 7035

    Supply includes:Roof plate including assembly parts.

    Packs of Model No. DK1 7411.000

  • NetworkingAcessories for Rittal Data Rack

    B

    5.1

    Net

    wo

    rkin

    g

    710 Rittal Catalogue 31/IT solutions

    Depth staysFor securing and stabilising two pairs of 482.6 mm (19) mounting angles in the data rack. The length of the depth stay is adjustable, and can accommodate all spacings of mounting angles.

    Colour:RAL 7035

    Depth staysPacks of Model No. DK

    2 7401.000

    Continuous slide railfor two pairs of mounting angles, 482.6 mm (19) The continuous slide rail is used to support heavy installed equipment in the Data Rack. The mounting dimensions of the slide rails were selected to enable them to be combined with 500 mm deep, 482.6 mm (19) component shelves. The mounting distance of the 482.6 mm (19) mounting angles is 350 mm.Requirements:Second pair of mounting angles

    Material:Sheet steel, zinc-plated, passivated

    Accessories:Component shelf, 500 mm deep, DK 7145.035, see page 944 .

    Packs of Model No. DK2 7402.000

    Levelling feetTo compensate for height differences with floor irregularities. The levelling feet are attached to the die-cast zinc feet of the base/plinth.

    Supply includes:4 levelling feet M12,levelling range 40 mm.

    Packs of Model No. DK4 7493.000