www.greencrossms.com hemoglobin A1c in human whole blood. GREENCARE A1c is a fully automated boronate affinity assay for determination of GREENCARE A1c provides the most convenient. Cassette optical reading area Hemoglobin A1c Test Kit Specification One Step HbA1c measuring system Fast & accurate result CV3%, in 4.5min. RELIABLE LCD touch screen Multi-lingual voice & video guide Built-in Thermal Printer EASY-TO-USE Single test cartridge containing synthetic materials (Bead, Washing solution) SIMPLE TEST STEPS Save freight cost Reduce concern for stability due to temp ROOM TEMPERATURE STABLE TEST KIT Model RT-100 Storage Condition Analyzer: 10~60 , 15~75% R.H. Operating Type Full automatic (1-Step) Test kit: 2~30 Measurement Time 4.5 min. Shelf life of Test kit 12 months Sample Type Capillary/Venous blood Rated Voltage 12 V DC - 3.33 A Sample Volume 3.5 ul Weight 1.6 kgs Measurement Range HbA1c 4.0~15.0 % (20~140 mmol/mol) Dimensions 205(W)x200(L)x150(H) mm eAG 68~385 mg/dL (mmol/L) Additional Function Full color touch screen Operating Condition Temperature: 17~32 Internal printer Humidity: 15~75% R.H. USB port, Ethernet Air pressure: 860~1,060 hpa External barcode reader available (optional)

One Step HbA1c measuring system · 2018. 5. 10. · One Step HbA1c measuring system One Step HbA1c measuring system One Step HbA1c measuring system D Built-in Thermal Printer Communication

  • Upload
    others

  • View
    18

  • Download
    1

Embed Size (px)

Citation preview

Page 1: One Step HbA1c measuring system · 2018. 5. 10. · One Step HbA1c measuring system One Step HbA1c measuring system One Step HbA1c measuring system D Built-in Thermal Printer Communication

www.greencrossms.com

hemoglobin A1c in human whole blood. GREENCARE A1c is a fully automated boronate a�nity assay for determination of

GREENCARE A1c provides the most convenient.

Cassette optical reading area

Hemoglobin A1c Test KitSpecification

One Step HbA1c measuring system

Fast & accurate result CV3%, in 4.5min.

RELIABLELCD touch screenMulti-lingual voice & video guideBuilt-in Thermal Printer

EASY-TO-USESingle test cartridge containing synthetic materials(Bead, Washing solution)

SIMPLE TEST STEPS

• Save freight cost• Reduce concern for stability due to temp

ROOM TEMPERATURE STABLE TEST KIT

Model RT-100 Storage Condition

Analyzer: 10~60 ℃, 15~75% R.H.Operating Type Full automatic (1-Step) Test kit: 2~30 ℃Measurement Time 4.5 min. Shelf life of Test kit 12 monthsSample Type Capillary/Venous blood Rated Voltage 12 V DC - 3.33 ASample Volume 3.5 ul Weight 1.6 kgs

Measurement RangeHbA1c 4.0~15.0 % (20~140 mmol/mol) Dimensions 205(W)x200(L)x150(H) mmeAG 68~385 mg/dL (mmol/L)

Additional Function

Full color touch screen

Operating ConditionTemperature: 17~32 ℃ Internal printerHumidity: 15~75% R.H. USB port, EthernetAir pressure: 860~1,060 hpa External barcode reader available (optional)

Page 2: One Step HbA1c measuring system · 2018. 5. 10. · One Step HbA1c measuring system One Step HbA1c measuring system One Step HbA1c measuring system D Built-in Thermal Printer Communication

One Step HbA1c measuring system

One Step HbA1c measuring system

One Step HbA1c measuring system

Built-in Thermal Printer

Communication Interface

SIMPLE TEST STEPS

GREENCARE A1c Hemoglobin A1c Test Kit

Manufactured by GREEN CROSS MEDIS CORP.Distributed by GREEN CROSS MEDICAL SCIENCE CORP.H.Q. : 107, Ihyeon-ro 30beon-gil, Giheung-gu, Yongin-si, Gyeonggi-do,446-770, Korea

Tel. :+82-31-260-0965,0969, 9663Fax. : +82-31-260-9416E-mail : [email protected]

http : //www.greencrossms.com R10IF0C00 (09/17)

No pipetting required

The GREENCARE A1c System was evaluated with 40 different samples provided by the NGSP.The results show high accuracy and excellent correlation.

Easy blood sampling No sample preparation

Reduced test errors by operator

Accuracy

Within-Run Precision (IFCC sample)Each of the samples was measured 20 times per each for precision using 2 meters across 3 lots.

IFCC calibrator Normal AbnormalMean HbA1c% 5.5 8.9

CV (%) 2.4 1.9

Difference, % GREENCARE A1c Systemwithin±3%within±6%within±10%

50%(20/40)92.5%(37/40)100%(40/40)

Day-to-day Precision (IFCC sample)Each of the samples was measured 1 time a day for 20 days using 2 meters across 3 lots.

IFCC calibrator Normal AbnormalMean HbA1c% 5.4 9.0

CV (%) 2.6 1.9

y = 0.9769x + 0.1592R² = 0.978

0.0

2.0

4.0

6.0

8.0

10.0

12.0

0.0 2.0 4.0 6.0 8.0 10.0 12.0

GREE

NCAR

E A1c

(A1c

%)

Regression Analysis

-12.0

-7.0

-2.0

3.0

8.0

0.0 2.0 4.0 6.0 8.0 10.0 12.0

Di�e

renc

e (%

)

Tosoh G7 (A1c%) Tosoh G7 (A1c%)

Accuracy analysis