2
Substance abuse testing with more substance. One simple device for saliva drug testing. Alere iScreen ® OFD Oral Fluid Drug Screening Device Toxicology

One simple device for saliva drug testing. Alere …documents.andatech.com.au/brochures/alere-iscreen-ofd...Substance abuse testing with more substance. One simple device for saliva

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: One simple device for saliva drug testing. Alere …documents.andatech.com.au/brochures/alere-iscreen-ofd...Substance abuse testing with more substance. One simple device for saliva

Substance abuse testing with more substance.

One simple device for saliva drug testing.

Alere iScreen® OFDOral Fluid Drug Screening Device

Toxicology

Page 2: One simple device for saliva drug testing. Alere …documents.andatech.com.au/brochures/alere-iscreen-ofd...Substance abuse testing with more substance. One simple device for saliva

Features & benefits• Accurately screen for illicit drugs in saliva

• Test remains in control of administrator

• No bathroom necessary

• Simple collection and testing procedure

• Results in as little as 10 minutes

• Long shelf life at room temperature storage

• Integrated internal procedural control

How it works

Catalogue no. Description No. of tests

IVDSB-755-011 Alere iScreen OFD DrugTest Device (Oral Fluid)

25 kits per box

Test Calibrator Test Calibrator Cut o�

Amphetamine (AMP) d-Amphetamine 50 ng/mL

Cocaine (COC) Benzoylecgonine 20 ng/mL

Cannabis (THC) 11-nor-∆9-THC-9-COOH 12 ng/mL

Methamphetamine (mAMP) d-Methamphetamine 50 ng/mL

Opiate (OPI) Morphine 40 ng/mL

©Alere. All Rights Reserved. The Alere Logo and Alere are trademarks of the Alere group of companies. A1797.

Please contact Alere for further information.

Australia

New Zealand

[email protected]

[email protected]

1800 622 642 Free call in AUS

0800 466 951 Free call in NZ

aler e.com.au

aler e.co.nz

Toxicology

Distributed by:Ordering Information

Oral Fluid Screening Device Cut o� Levels

If results are presumptive positive, secure Cap with Security Seal and send to laboratory for confirmation.

PRODUCT PROCEDURE NOTE: Refer toproduct insert for complete instructions,limitations, and warnings.This assay provides only a preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS), gas chromatography/tandem mass spectrometry (GC/MS/MS) and liquid chromatography/tandem mass spectrometry (LC/MS/MS) are the preferred confirmatory methods. Clinical consideration and professional judgement should be applied to any drug of abuse test result, particularly when preliminary positive results are indicated.

Remove Sample CollectorProtector and insert Spongeend of collector into mouth.

Actively swab theinside of the mouthand tongue with Sponge.

Insert the collectorvertically into the Capand twist the Handleclockwise 180 o totighten the Cap.Read results at10 minutes.

Vertically

180 O

Cap

White Mark

White Mark

Sample Port

Sample Collector P rotector

Red Ar row

Handle

Sponge

Andatech Pty LtdPO Box 3038Nunawading VIC 3131AustraliaPhone: 1300 800 200 Website: www.andatech.com.au