2
Toll Free: 1 866 761-1535 | www.mastermeter.ca See reverse side for more specifications » The easy and reliable upgrade for DIALOG registers. The Master Meter Dual Switch Output Module provides a reliable signal between the DIALOG register and the DIALOG 3G External Transceiver. Completely potted for superior moisture protection. Factory tested to 50,000,000 cycles. Reed Switch assembly is provided from the factory sealed with 4 feet (1.2 m), 24 gauge, 2-conductor stranded cable. Remote counting or batching equipment can be installed up to 500 feet (150 m) from meter, connected by 24 gauge, 2-conductor stranded cable (if equipment allows, most electronic counters only allow up to 30 feet [9 m]). BENEFITS & FEATURES For use with all Master Meter water meters equipped with DIALOG registers • Durable casing, 24 gauge cable Potted with proprietary resin impervious to moisture penetration • Factory tested to 50,000 cycles Dual Switch Output Module ON-SITE METER READING TECHNICAL SPECIFICATIONS Description Two switch output assembly compatible with Master Meter DIALOG Register. Switch Type Dry contact reed Switch Type Proximity Sensor. Factory tested to 50,000,000 cycles. Case All electronics housed in a durable, engineered plastic case, upgraded to resist moisture penetration and ultraviolet degradation. Sealing Encoder and connectors potted with proprietary resin impervious to moisture penetration. Maximum Switch Current 500 mA Maximum Recommended Switching Voltage 32 volts (AC or DC) WARNING: We recommend contacts be kept within the parameters stated Contact Resistance 70 ohms Power Requirements Dual Switch Output Assembly has no power supply of its own. Power derived from external source such as the peripherals attached to it. Compatible Equipment LCD Remote Counter, RF Transmitters, Electrical/ electronic counters, totalizers, or actuators, or any equipment requiring single or double closed contact input. Wiring/Distances Reed Switch assembly is provided from the factory sealed with 4 feet (1.2 m), 24 gauge, 2-conductor stranded cable. Remote counting or batching equipment can be installed up to 500 feet (150 m) from meter, connected by 24 gauge, 2-conductor stranded cable (if equipment allows, most electronic counters only allow up to 30 feet [9 m]). Warranty One year from date of shipment. | [email protected] | Phone: 877.566.3837 | Fax: 925.407.2903

ON-SITE METER READING Dual Switch Output Modulemetervalveandcontrol.com/pdf/water-meters/02-SMJ/05b-DUAL SWITC… · The Master Meter Dual Switch Output Module provides a reliable

  • Upload
    dotruc

  • View
    219

  • Download
    0

Embed Size (px)

Citation preview

Toll Free: 1 866 761-1535 | www.mastermeter.ca

See reverse side for more specifi cations »

The easy and reliable upgrade for DIALOG registers.

The Master Meter Dual Switch Output Module provides a reliable signal between the DIALOG register and the DIALOG 3G External Transceiver. Completely potted for superior moisture protection.

Factory tested to 50,000,000 cycles. Reed Switch assembly is provided from the factory sealed with 4 feet (1.2 m), 24 gauge, 2-conductor stranded cable. Remote counting or batching equipment can be installed up to 500 feet (150 m) from meter, connected by 24 gauge, 2-conductor stranded cable (if equipment allows, most electronic counters only allow up to 30 feet [9 m]).

BENEFITS & FEATURES

• For use with all Master Meter water meters equipped with DIALOG registers

• Durable casing, 24 gauge cable

• Potted with proprietary resin impervious to moisture penetration

• Factory tested to 50,000 cycles

Dual Switch Output Module

ON-SITE METER READING

TECHNICAL SPECIFICATIONS

Description Two switch output assembly compatible with Master Meter DIALOG Register.

Switch Type Dry contact reed Switch Type Proximity Sensor. Factory tested to 50,000,000 cycles.

Case All electronics housed in a durable, engineered plastic case, upgraded to resist moisture penetration and ultraviolet degradation.

Sealing Encoder and connectors potted with proprietary resin impervious to moisture penetration.

Maximum Switch Current

500 mA

Maximum Recommended

Switching Voltage

32 volts (AC or DC)

WARNING: We recommend contacts be kept within the parameters stated

Contact Resistance

70 ohms

Power Requirements

Dual Switch Output Assembly has no power supply of its own. Power derived from external source such as the peripherals attached to it.

Compatible Equipment

LCD Remote Counter, RF Transmitters, Electrical/electronic counters, totalizers, or actuators, or any equipment requiring single or double closed contact input.

Wiring/Distances Reed Switch assembly is provided from the factory sealed with 4 feet (1.2 m), 24 gauge, 2-conductor stranded cable. Remote counting or batching equipment can be installed up to 500 feet (150 m) from meter, connected by 24 gauge, 2-conductor stranded cable (if equipment allows, most electronic counters only allow up to 30 feet [9 m]).

Warranty One year from date of shipment.

| [email protected] | Phone: 877.566.3837 | Fax: 925.407.2903

Master Meter Canada • 100 Lansdowne Street, Suite 207 • St-Bruno, Québec J3V 0B3 Toll free: 1 866 761-1535 • Phone: (450) 461-1535 • Fax: (450) 461-3720

www.mastermeter.ca [email protected]

©2005 Master Meter, Inc. All rights reserved. DIALOG and Master Meter are registered trademarks of Master Meter, Inc. Master Meter reserves the right to make modifications to the products described herein at any time and without notice. U.S. Patent No. 6,819,292, Patent No. 6,954,178. Others pending. EnviroBrass® is a registered trademark of ASARCO.