28
2/8/2019 Page 1 On-Line Process GC Flare Measurement On-line GC Solution to comply with Flare Measurement Requirements Ulrich Gokeler Analytical Products & Solutions Houston, TX

On-line GC Solution to comply with Flare 4C Presentation (USA) · On-Line Process GC Flare Measurement 2/8/2019 Page 18 Flare Measurement - Similar Regulations RSR HRVOC Objective

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: On-line GC Solution to comply with Flare 4C Presentation (USA) · On-Line Process GC Flare Measurement 2/8/2019 Page 18 Flare Measurement - Similar Regulations RSR HRVOC Objective

2/8/2019 Page 1On-Line Process GC Flare Measurement

On-line GC Solution to comply with Flare Measurement Requirements

Ulrich GokelerAnalytical Products & SolutionsHouston, TX

Page 2: On-line GC Solution to comply with Flare 4C Presentation (USA) · On-Line Process GC Flare Measurement 2/8/2019 Page 18 Flare Measurement - Similar Regulations RSR HRVOC Objective

2/8/2019 Page 2On-Line Process GC Flare Measurement

ObjectivesNumerous federal, state and regional regulations require to monitor industrial flares with the objective to quantify emission and optimize combustion efficiency. There is the just implemented federal regulation 63.670 Refinery Sector Rule (RSR), the recent Sub Part Ja also targeting refinery flares, Chapter 115 (HRVOC) of the Texan TCEQ targeting olefin emission in the Houston-Galveston area or Rule 1118 of the South Coast Air Quality Monitoring District (SCAQMD) just to mention a few. There are similarities between a number of those regulations, although with some subtle differences, permitting to share the same analytical configuration and measurement system to satisfy different regulations. Often GCs are the default choice because reliability, familiarity and maintainability which over many years has been proven often to be the best choice. However, as with many on-line analyzers the success of reliable measurement is not necessarily the analyzer but sample transport, sample conditioning, measurement system understanding, validation needs and simplicity of maintenance. This presentation discusses similarities and differences of some of those regulations and Process GC measurement solutions proven over many years of operation.

Page 3: On-line GC Solution to comply with Flare 4C Presentation (USA) · On-Line Process GC Flare Measurement 2/8/2019 Page 18 Flare Measurement - Similar Regulations RSR HRVOC Objective

2/8/2019 Page 3On-Line Process GC Flare Measurement

Flare Measurement• Rules

• RSR Refinery Sector Rule 40CFR Part 63.670

• HRVOC TCEQ Chapter 115

• Rule 1118 South Coast Air Quality Monitoring District

• Consents Bilateral consent agreements

• J 40 CFR 60 Sub Part J

• Ja 40CFR 60 Sub Part Ja

Expecting

• ESR Ethylene Sector Rule

• CSR “Chemical” Sector Rule

Maxumedition II

s

Maxumedition II

s

Maxumedition II

s

Gas RecoveryFlare Headers

Page 4: On-line GC Solution to comply with Flare 4C Presentation (USA) · On-Line Process GC Flare Measurement 2/8/2019 Page 18 Flare Measurement - Similar Regulations RSR HRVOC Objective

2/8/2019 Page 4On-Line Process GC Flare Measurement

Flare Measurement• Discussions often focus on analyzer

• System Solution• Not often discussed in detail

• Is decisive

• Needs experience

www.us.siemens.com/processanalyticswww.industry.usa.siemens.com/automation/us/en/process-instrumentation-and-analytics/solutions-for-industry/environmental-monitoring/Pages/environmental-monitoring.aspxwww.union-instruments.com/en/products/calorimeter-cwdwww.deltainstrument.com/calorimeters.htmlwww.precisive-instruments.comwww.extrel.com

Page 5: On-line GC Solution to comply with Flare 4C Presentation (USA) · On-Line Process GC Flare Measurement 2/8/2019 Page 18 Flare Measurement - Similar Regulations RSR HRVOC Objective

2/8/2019 Page 5On-Line Process GC Flare Measurement

Flare Measurement SystemTo Flare 

Sample Return

Fast loop Return

Page 6: On-line GC Solution to comply with Flare 4C Presentation (USA) · On-Line Process GC Flare Measurement 2/8/2019 Page 18 Flare Measurement - Similar Regulations RSR HRVOC Objective

2/8/2019 Page 6On-Line Process GC Flare Measurement

Flare Measurement System

• Sample Conditioning• Heating

• “Cold” flares• “Hot” flares

• Filter• Particulates & Coalescent

• Traditional Design• Periodic visual inspection of P, T, F, condensate

• Smart Design• T,P and flow of analytical loop and possibly fast loop• Multivariable smart devices bus linked to analyzer• Monitored via analyzer and workstation

• Valving• Stream / Flare select• Purge• Cal/Val selection

Smart Sample System at 60oC

Sample system at 120oC

Page 7: On-line GC Solution to comply with Flare 4C Presentation (USA) · On-Line Process GC Flare Measurement 2/8/2019 Page 18 Flare Measurement - Similar Regulations RSR HRVOC Objective

2/8/2019 Page 7On-Line Process GC Flare Measurement

Flare Measurement System

• Validation• Analyzer• Measurement System

• Standards• Number of cylinders

• GC, BTU typically 3 (multi components)

Heated Cabinet for Calibration/Validation 

Page 8: On-line GC Solution to comply with Flare 4C Presentation (USA) · On-Line Process GC Flare Measurement 2/8/2019 Page 18 Flare Measurement - Similar Regulations RSR HRVOC Objective

2/8/2019 Page 8On-Line Process GC Flare Measurement

Flare Measurement System

• Validation• Analyzer• Measurement System

• Standards• Number of cylinders

• GC, BTU typically 3 (multi components)• MassSpec 8+ (few comp./cylinder)• IR Interferential Lab analysis, or GC, or MS

Open Air Cabinet for Flare MassSpec Calibration/Validation 

Page 9: On-line GC Solution to comply with Flare 4C Presentation (USA) · On-Line Process GC Flare Measurement 2/8/2019 Page 18 Flare Measurement - Similar Regulations RSR HRVOC Objective

2/8/2019 Page 9On-Line Process GC Flare Measurement

Process GC Flare Measurement Solution

• On-Line Process Gas Chromatograph• Most flexible analytical technology• Most widely used multi component analyzer• Physical separation of target components• Direct measurement of components, not inferred• High uptimes• Predictable• Maintainable

Page 10: On-line GC Solution to comply with Flare 4C Presentation (USA) · On-Line Process GC Flare Measurement 2/8/2019 Page 18 Flare Measurement - Similar Regulations RSR HRVOC Objective

2/8/2019 Page 10On-Line Process GC Flare Measurement

Process GC – Complexity?

• Process Gas Chromatograph

• Perception of • Complexity• Long cycle Times• Long time experience

• Not if done correctly!

Page 11: On-line GC Solution to comply with Flare 4C Presentation (USA) · On-Line Process GC Flare Measurement 2/8/2019 Page 18 Flare Measurement - Similar Regulations RSR HRVOC Objective

2/8/2019 Page 11On-Line Process GC Flare Measurement

Process GC - Separation

• Traditional• Multi valve and multi separation columns• Complexity leading to challenges

• Understanding• Maintainability• Cycle time

• Traditional GC analytics needs simplification

1 2

5 4

6 3V11 2

5 4

6 3V3

1

Sample

Pre Column

Injection Volume

1 2

5 4

6 3V2

Carrier Gas

ITC1 2

5 4

6 3V4

2

5

3 4

Column 2

Column 5 Detector

1 2

5 4

6 3

1 2

5 4

6 3V11 2

5 4

6 3

1 2

5 4

6 3V3

1

Sample

Pre Column

Injection Volume

1 2

5 4

6 3

1 2

5 4

6 3V2

Carrier Gas

ITC1 2

5 4

6 3

1 2

5 4

6 3V4

2

5

3 4

Column 2

Column 5 Detector

Met

hane

i-Pen

tane

N-B

utan

ei-B

utan

eP

ropa

ne

Hex

ane

+

Nitr

ogen

Oxy

gen

& A

rgon

Eth

ane

Car

bon

Dio

xide

n-P

enta

ne

Star

t

8.5

min

utes

Met

hane

i-Pen

tane

N-B

utan

ei-B

utan

eP

ropa

ne

Hex

ane

+

Nitr

ogen

Oxy

gen

& A

rgon

Eth

ane

Car

bon

Dio

xide

n-P

enta

ne

Star

t

8.5

min

utes

Page 12: On-line GC Solution to comply with Flare 4C Presentation (USA) · On-Line Process GC Flare Measurement 2/8/2019 Page 18 Flare Measurement - Similar Regulations RSR HRVOC Objective

2/8/2019 Page 12On-Line Process GC Flare Measurement

Process GC - Separation

• Parallel Chromatography• Multiple simple column trains

• Simple Backflush• Multiple detectors0

5

5

2

5

3

5

4

Serial Chromatography

Segmentation of analytical task –Analyze each segment independently

23

67

8

1

10 4

9 5

Column 1

Column 2

S S S R

Detector Vents

Sample

Injection Volume

Carrier Gas

23

67

8

1

10 4

9 5

Column 1

Column 2

S S S R

Detector Vents

Sample

Injection Volume

Carrier Gas

AppletSingle Column Train

Page 13: On-line GC Solution to comply with Flare 4C Presentation (USA) · On-Line Process GC Flare Measurement 2/8/2019 Page 18 Flare Measurement - Similar Regulations RSR HRVOC Objective

2/8/2019 Page 13On-Line Process GC Flare Measurement

Process GC - Separation

Old Style “Serial GC” Maxum “Parallel GC”

1

3

4

2

5

6SV1

1

3

4

2

5

6 CV1

1

3

4

2

5

6 CV2

I S R

TC Detector

Det. Vent

Ref. Vent

Carrier

Carrier

SampleIn

SampleOut

1

3

4

2

5

6 CV3

Col 1

Col 2

Col 4

Col 3

Col 5

1

5

10

9

87

6

4

32

SampleReturn

DetectorVents

CarrierFrom EPC

SampleIn

S-1 S-2 S-3 Ref

Column 2

Column 1

SSO

Restrictors

Page 14: On-line GC Solution to comply with Flare 4C Presentation (USA) · On-Line Process GC Flare Measurement 2/8/2019 Page 18 Flare Measurement - Similar Regulations RSR HRVOC Objective

2/8/2019 Page 14On-Line Process GC Flare Measurement

Process GC - Flare Measurement

• Example of full H2-C5+ analysis

• Parallel Chromatography• Multi simple column trains

• Simple Backflush• Multiple detectors

• Simplification • Understanding • Maintenance• Shorter cycle time

• Performance Improvement• On-line time 98-99.5%

(possible 99.7%)

1

2

3

Page 15: On-line GC Solution to comply with Flare 4C Presentation (USA) · On-Line Process GC Flare Measurement 2/8/2019 Page 18 Flare Measurement - Similar Regulations RSR HRVOC Objective

2/8/2019 Page 15On-Line Process GC Flare Measurement

Process GC - Flare Measurement

• Maintenance in Place• Utilized widespread• Familiarity• Experience

• Maintenance by Exchange• Module based• Module consist of separation columns, valves and

detectors on common mating base plate• Standard column trains• Exchange, heat-up and validation ~2-3 hours.

Page 16: On-line GC Solution to comply with Flare 4C Presentation (USA) · On-Line Process GC Flare Measurement 2/8/2019 Page 18 Flare Measurement - Similar Regulations RSR HRVOC Objective

2/8/2019 Page 16On-Line Process GC Flare Measurement

Process GC - Flare Measurement Performance

Component Range Linearity R2

MSR - Hydrogen 0-100% 0.999MSR - Argon/Oxygen 0-100% 0.9999MSR - Nitrogen 0-100% 1MSR - CO 0-100% 0.9999Methane 0-100% 0.9999CO2 0-100% 1Ethane 0-100% 1Ethylene 0-100% 1Acetylene 0-100% 1Propane 0-100% 1Propylene 0-100% 1i-Butane 0-100% 0.9999n-Butane 0-100% 0.9999i-Butylene 0-100% 0.9993cis-2-Butylene 0-100% 0.9999trans-2-Butylene 0-100% 0.99951.3-Butadiene 0-100% 0.9997i-Pentane + 0-100% 1

Component% rel. STDev.

6 days

Component Concentrations

Mol %MSR - Hydrogen 0.75 5.90MSR - Argon / Oxygen 0.45 0.41MSR - Nitrogen 0.35 23.80MSR - Carbon Monoxide 1.26 0.16Methane 0.32 16.00Carbon Dioxide 0.24 0.68*Ethylene 0.23 5.60Ethane 0.23 6.30Acetylene 0.27 0.57Propane 0.20 15.20*Propylene 0.20 11.50i-Butane 0.35 2.00n-Butane 0.24 4.30*i-Butene & Butene-1 0.22 8.50*Trans-2-Butene 0.24 3.50*Cis-2-Butene 0.25 3.36*1,3-Butadiene 0.31 3.80i-Pentane (Plus) 0.46 0.53

Linearity R2 = 0.999-1 (0.01-100%) Repeatability RSD 0.2-0.6% (6 days)

Why 3‐point validation? Why daily validation?

Page 17: On-line GC Solution to comply with Flare 4C Presentation (USA) · On-Line Process GC Flare Measurement 2/8/2019 Page 18 Flare Measurement - Similar Regulations RSR HRVOC Objective

2/8/2019 Page 17On-Line Process GC Flare Measurement

Process GC – Cycle Time

Measurement Cycle Time(min)

Objective Applicability

Hydrogen 0.5-0.75 BTU Benefit RSR, HRVOCNitrogen 1 - 1.5 Flowmeter All regsAir, C1-C4+ 2 BTU RSR Air, C1-C5+ 3 BTU RSRH2, N2, CO2, C1-C5+ Paraffins 3 BTU RSR, HRVOCH2, N2, CO, CO2, C1-C5+ Paraffins & Olefins 7.5 BTU HRVOC

H2S 3-5 Sulfur Emission J, JaTotal Sulfur 3 Sulfur Emission Ja, 1118

Page 18: On-line GC Solution to comply with Flare 4C Presentation (USA) · On-Line Process GC Flare Measurement 2/8/2019 Page 18 Flare Measurement - Similar Regulations RSR HRVOC Objective

2/8/2019 Page 18On-Line Process GC Flare Measurement

Flare Measurement - Similar Regulations

RSR HRVOCObjective Combustion Efficiency Olefin emissionControl BTU in combustion zone >300 BTUFlow quantification T, P, F  T, P, F

Measurement All or H2, C2‐C5N2

C2‐C4 Olefins as presentH2, N2, C1‐C5+, H2O a.o.

Measurement Frequency minimum 4 results/hr. minimum 4 results/hr.

ValidationBTU individual componentsPS 9 PS 9

min. 60oC min. 60oC

Validation Frequencydaily mid point (single analysis)

weekly mid point (triplicate)

quarterly low/mid/high quarterly low/mid/high

Validation Target "All" or H2 & C1‐C5 n‐ParaffinsOlefins, 

"all" or main BTU contributors

Page 19: On-line GC Solution to comply with Flare 4C Presentation (USA) · On-Line Process GC Flare Measurement 2/8/2019 Page 18 Flare Measurement - Similar Regulations RSR HRVOC Objective

2/8/2019 Page 19On-Line Process GC Flare Measurement

Flare Measurement - Similar Regulations

RSR HRVOCObjective Combustion Efficiency Olefin EmissionControl BTU in combustion zone >300 BTUFlow quantification T, P, F  T, P, F

Measurement All or H2, C2‐C5N2

C2‐C4 Olefins as presentH2, N2, C1‐C5+, H2O a.o.

Measurement Frequency minimum 4 results/hr. minimum 4 results/hr.

ValidationBTU individual componentsPS 9 PS 9

min. 60oC min. 60oC

Validation Frequencydaily mid point (single analysis)

weekly mid point (triplicate)

quarterly low/mid/high quarterly low/mid/high

Validation Target "All" or H2 & C1‐C5 n‐ParaffinsOlefins, 

"all" or main BTU contributors

Page 20: On-line GC Solution to comply with Flare 4C Presentation (USA) · On-Line Process GC Flare Measurement 2/8/2019 Page 18 Flare Measurement - Similar Regulations RSR HRVOC Objective

2/8/2019 Page 20On-Line Process GC Flare Measurement

Components Range % HRVOC RSR Components Range % HRVOC RSR

Hydrogen 0-100 i - Butane 0-100Oxygen & Argon 0-100 n-Butane 0-100Carbon Monoxide 0-100 i-& 1-Butene 0-100Nitrogen 0-100 tr-2-Butene 0-100Methane 0-100 cis-2-Butene 0-100Carbon Dioxide 0-100 1,3-Butadiene 0-100Ethane 0-100 i-C5+ 0- 50Ethylene 0-100 n-C5+ 0- 50H2S 0‐ 100 n-Pentane 0- 50Acetylene 0-100 i-C6+ 0- 20Propane 0-100 Water 0‐  30Propylene 0-100 a.o. Benzene 0- 10

Val

Alt.Val

Val

Val

Alt.Val

Val

Flare Measurement - Validation

Page 21: On-line GC Solution to comply with Flare 4C Presentation (USA) · On-Line Process GC Flare Measurement 2/8/2019 Page 18 Flare Measurement - Similar Regulations RSR HRVOC Objective

2/8/2019 Page 21On-Line Process GC Flare Measurement

Components Range % HRVOC RSR Components Range % HRVOC RSR

Hydrogen 0-100 i - Butane 0-100Oxygen & Argon 0-100 n-Butane 0-100Carbon Monoxide 0-100 i-& 1-Butene 0-100Nitrogen 0-100 tr-2-Butene 0-100Methane 0-100 cis-2-Butene 0-100Carbon Dioxide 0-100 1,3-Butadiene 0-100Ethane 0-100 i-C5+ 0- 50Ethylene 0-100 n-C5+ 0- 50H2S 0‐ 100 n-Pentane 0- 50Acetylene 0-100 i-C6+ 0- 20Propane 0-100 Water 0‐  30Propylene 0-100 a.o. Benzene 0- 10

Val

Alt.Val

Val

Val

Alt.Val

Val

Flare Measurement - Validation

Alternative Surrogate Calibration/Validation simplifies => fewer cylinders, higher pressure/gas volume

Page 22: On-line GC Solution to comply with Flare 4C Presentation (USA) · On-Line Process GC Flare Measurement 2/8/2019 Page 18 Flare Measurement - Similar Regulations RSR HRVOC Objective

2/8/2019 Page 22On-Line Process GC Flare Measurement

Components Range % HRVOC RSR Components Range % HRVOC RSR

Hydrogen 0-100 i - Butane 0-100Oxygen & Argon 0-100 n-Butane 0-100Carbon Monoxide 0-100 i-& 1-Butene 0-100Nitrogen 0-100 tr-2-Butene 0-100Methane 0-100 cis-2-Butene 0-100Carbon Dioxide 0-100 1,3-Butadiene 0-100Ethane 0-100 i-C5+ 0- 50Ethylene 0-100 n-C5+ 0- 50H2S 0‐ 100 n-Pentane 0- 50Acetylene 0-100 i-C6+ 0- 20Propane 0-100 Water 0‐  30Propylene 0-100 a.o. Benzene 0- 10

Val

Alt.Val

Val

Val

Alt.Val

Val

Flare Measurement - Validation Similarities

Utilize same analyzer for multiple regulatory requirements

Page 23: On-line GC Solution to comply with Flare 4C Presentation (USA) · On-Line Process GC Flare Measurement 2/8/2019 Page 18 Flare Measurement - Similar Regulations RSR HRVOC Objective

2/8/2019 Page 23On-Line Process GC Flare Measurement

Multi Purpose Flare Analyzer System

• Similar Regulations• RSR, TCEQ Chapter 115, SCAQMD 1118,

Consent Agreements

• Objectives• Regulation compliance• Internal objectives

• Sample Temperature• Sample transport• Sample system

• Validation• Single• Triplicate• Analyzer• Measurement System

• BTU Calculation• Heat Values according individual rules

• Downtime• Validation according different rules may

incur additional down time

Page 24: On-line GC Solution to comply with Flare 4C Presentation (USA) · On-Line Process GC Flare Measurement 2/8/2019 Page 18 Flare Measurement - Similar Regulations RSR HRVOC Objective

2/8/2019 Page 24On-Line Process GC Flare Measurement

Technological Options & Suitability

Objective is BTU value in Combustion Zone

Composition dependent Steam/Air addition enables optimized combustion

Add GC for 

optimization

Add H2

No speciation

Specia‐tion

HRVOCOlefins

HRVOCBTU

RSR H2 N2 Speed Complexity Standards Cost

Calorimeter    Add H2   <30 sec User 1‐3 0

IR Inferential Add GC foroptimization      30 sec Vendor multiple 0

Mass Spec       30 sec Vendor/User 8 ‐ ? +

Process GC       90‐450 sec(scope dependent)

User 1 ‐ 3 ‐Based on public information and comments by customers.

<30 sec

<30 sec

Extractive, need Sample System & Basic Weather Protection

Page 25: On-line GC Solution to comply with Flare 4C Presentation (USA) · On-Line Process GC Flare Measurement 2/8/2019 Page 18 Flare Measurement - Similar Regulations RSR HRVOC Objective

2/8/2019 Page 25On-Line Process GC Flare Measurement

Process GC – Flare Experience

• Flare GCs• Since >20 years• >500 in operation

• Sample Conditions• Liquid Slugs / Sample dew point

• Steady state • Upset conditions

• Sample system design• Coalescence Filter• 60oC => 110oC• Purge option• Smartness

• Pump• Redundancy

Page 26: On-line GC Solution to comply with Flare 4C Presentation (USA) · On-Line Process GC Flare Measurement 2/8/2019 Page 18 Flare Measurement - Similar Regulations RSR HRVOC Objective

2/8/2019 Page 26On-Line Process GC Flare Measurement

Process GC – Flare Experience

• Validation• Standards

• Number of constituents• Number of cylinders• Temperature equilibration

• Memory• Sample line inertness• Purge volume

• Maintainability• Analytical system simplicity

• On-site understanding• On-site maintainability

Page 27: On-line GC Solution to comply with Flare 4C Presentation (USA) · On-Line Process GC Flare Measurement 2/8/2019 Page 18 Flare Measurement - Similar Regulations RSR HRVOC Objective

2/8/2019 Page 27On-Line Process GC Flare Measurement

Process GC - Summary

• On-line Process Gas Chromatography• Most widely used speciated measurement solution

• Risk reduction• Proven solutions• Front-end measurement assessment• Turn-key measurement system including sample extraction, sample

conditioning, analyzer, system packaging

• Permits Minimizing Validation complexity• Minimize validation components/standards

• Permits Commonly on-site Maintainability by User• Easiest to maintain by on-site technicians

• Analyzer hit by condensate slugs• Composition change/range adaptation

• Utilize Measurement System for Multiple Rules or in redundant configuration

Page 28: On-line GC Solution to comply with Flare 4C Presentation (USA) · On-Line Process GC Flare Measurement 2/8/2019 Page 18 Flare Measurement - Similar Regulations RSR HRVOC Objective

2/8/2019 Page 28On-Line Process GC Flare Measurement

On-line GC Solution to comply with Flare Measurement RequirementsUlrich GokelerStrategic SupportSiemens Industry, Inc.Analytical Products & Solutions

Houston, TX 77041. USAPhone: 713 417 3864E-mail: [email protected]