Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
7.55"RADIUS
11.70"
5.80"
3.00"
RISER/COLUMN PIPEDISCHARGE/LEAK DETEC TO RCENTERLINE CENTERLINE
LINE TEST PO RT
10.45"8.12"
RADIUS
UP FOR SE R VICE
DOWN FOR TEST
LINEPRESSURE
TEST
RE
C
EL
E
TR E MOVING
C OVE R
T IGHT
R
D
IR
E' VELN
VUO
CR
N
C
A VL E
A
VU
OTI
IU
K E E P
C OVE R
B E FOR E
OP E N
C IR
C UIT
EL
CR
OP E N
C IR C UIT
R E MOVING
C OVE R
B E FOR E
E
C OVE R
T IGHTK E E P
VR
EUO
CU
I L C
T
E N'D
C
L
NV A
AEE V
ELR
RIEL T
CRI
V ROU
8.00"
5.75"
6.75"
6.31"
3.31"
4.94"
11.00"
6.31"
3.13"
3" PIPE PLUG IF ONL Y ON E
SIDE OF MANIFOLD USED
(FURNISHED BY CUSTOMER)
CA L MAKEUP
POINT (1" NPT)
TANK PO RT
TECHNICALBULLETIN
June 19, 2014 • TB0614-01
Connecting a T5 Series Fuel Management System or Colibri Tank Monitor to an ALVIC SCS3 Point of Sale System
OverviewThis document explains how to connect a T5 Series Fuel Management System or Colibri Tank Monitor to an ALVIC SCS3 System and allow the ALVIC system to receive inventory information from the T5 Series or Colibri tank monitor. In applications where dispenser reconciliation is desired, it will also allow the ALVIC system to send sales information to the T5 Series or Colibri Tank Monitor, without the need for a TS-DIMIB (Dispenser Interface Module).
Requirements• T5 Series Controller Module software version 1.8.0.6620 or greater. Colibri version 1.8.3.7080.
CommunicationsOn the ALVIC System, Configuring SCS3 for a Franklin ATG
For the SCS3 to work with Franklin Fueling Systems T5 series and Colibri tank monitors, you need to configure the SCS3.XML file with the following parameters.
<TipoSonda>9</TipoSonda>
Add the following nodes after the <IntervaloStock>
<Url>http://192.168.168.168/cgi-bin/tsaws.cgi</Url> //
Replace the IP: 192.168.168.168 with the correct one that corresponds to the console.
<UserPwd>admin</UserPwd> //
The parameter admin should only be changed if the administrator password at the tank gauge monitor had been changed from factory defaults, and should be replaced by the new administrator password.
Example:
7.55"RADIUS
11.70"
5.80"
3.00"
RISER/COLUMN PIPEDISCHARGE/LEAK DETEC TO RCENTERLINE CENTERLINE
LINE TEST PO RT
10.45"8.12"
RADIUS
UP FOR SE R VICE
DOWN FOR TEST
LINEPRESSURE
TEST
RE
C
EL
E
TR E MOVING
C OVE R
T IGHT
R
D
IR
E' VELN
VUO
CR
N
C
A VL E
A
VU
OTI
IU
K E E P
C OVE R
B E FOR E
OP E N
C IR
C UIT
EL
CR
OP E N
C IR C UIT
R E MOVING
C OVE R
B E FOR E
E
C OVE R
T IGHTK E E P
VR
EUO
CU
I L C
T
E N'D
C
L
NV A
AEE V
ELR
RIEL T
CRI
V ROU
8.00"
5.75"
6.75"
6.31"
3.31"
4.94"
11.00"
6.31"
3.13"
3" PIPE PLUG IF ONL Y ON E
SIDE OF MANIFOLD USED
(FURNISHED BY CUSTOMER)
CA L MAKEUP
POINT (1" NPT)
TANK PO RT
TECHNICALBULLETIN
For Tank Monitor Reconciliation and Auto Calibration If reconciliation is necessary by the Tank Gauge monitor, besides activating reconciliation as it was explained before, you should program the dispensers as it is shown next:
In the figure above, you can see an example of a reconciliation configuration, where the relationship between the hose, dispenser, and tank is shown. In this way hose number 1 from dispenser 1 uses tank 1, and the hose number 1 from dispenser 4 uses tank 3.
Also this figure belongs to the table grid equivalence between ALVIC and Franklin Fueling Systems T5 and Colibri tank monitors, the red highlighted figures references the tank gauge setup.
• When it says, Surtidor ID = 1, This dispenser is from the SCP not the console.• When it says, Manguera ID = 1, This hose is from the SCS. • What it is inside the node <Manguera ID=XX> … </Manguera> it references the tank gauge console setup.
On the T5 Series or Colibri Tank Monitor
• A standard CAT5 cable is used for a direct network connection from switch / router to the T5 Series Ethernet port.• Confirm the port programming in the T5 Series Setup.
TS550 / 5000 / Colibri• System-Configuration-Protocol Settings
Protocol Settings
Veeder-Root Port 8001Veeder-Root Client Timeout 0Web Server Secondary Port 10001
TS550 evo• Setup-Parameters-Communications-Protocols
CommunicationsSerial Ports
... ...
Modem Type NoneProtocols Veeder-Root
Port
Veeder-Root Client Timeout
8001
0
7.55"RADIUS
11.70"
5.80"
3.00"
RISER/COLUMN PIPEDISCHARGE/LEAK DETEC TO RCENTERLINE CENTERLINE
LINE TEST PO RT
10.45"8.12"
RADIUS
UP FOR SE R VICE
DOWN FOR TEST
LINEPRESSURE
TEST
RE
C
EL
E
TR E MOVING
C OVE R
T IGHT
R
D
IR
E' VELN
VUO
CR
N
C
A VL E
A
VU
OTI
IU
K E E P
C OVE R
B E FOR E
OP E N
C IR
C UIT
EL
CR
OP E N
C IR C UIT
R E MOVING
C OVE R
B E FOR E
E
C OVE R
T IGHTK E E P
VR
EUO
CU
I L C
T
E N'D
C
L
NV A
AEE V
ELR
RIEL T
CRI
V ROU
8.00"
5.75"
6.75"
6.31"
3.31"
4.94"
11.00"
6.31"
3.13"
3" PIPE PLUG IF ONL Y ON E
SIDE OF MANIFOLD USED
(FURNISHED BY CUSTOMER)
CA L MAKEUP
POINT (1" NPT)
TANK PO RT
TECHNICALBULLETIN
Verify OperationALVIC SCS3 Receiving Tank Inventory
• Check the ALVIC display to ensure there are no indications of the Tank Monitor being Offline.• Verify that the ALVIC system is receiving tank level information. From the main screen, select Other Functions / Tank
LevelsTank Level information will be displayed on the screen.
• T5 Series Receiving Dispenser Sales Information (BIR)To process the dispenser sales information being sent from the ALVIC system, the T5 Series or Colibri must be setup with the correct Dispenser Interface programming. The Grades and Fueling Point information must be entered. A successful Query at a Fueling Point confirms that the T5 Series or Colibri is receiving sales information.
For specific information on Dispenser Interface programming and using the Query function, refer to the T5 Series Full Management System Programming Guide FFS 000-2142 or the Colibri Setup and Operation guide 000-2155.
For assistance, call Franklin Fueling Technical Support at 800-984-6266.
Franklin Fueling Systems • 3760 Marsh Rd. • Madison, WI 53718 USA
Tel: +1 608 838 8786 • 800 225 9787 • Fax: +1 608 838 6433 • www.franklinfueling.com