13
No . ERYT030D Original om Ron EU DECLARATION OF CONFORMITY 1. Product Models/Products: Power Relay G7Z Series 2. Name and address of the manufacturer: OMRON Corporation Shiokoji Horikawa Shimogyo-Ku. Kyoto. 600-8530 Japan 3. This declaration of conformity is issued under the sole responsibility of the manufacturer. 4. Objects of the declaration: G7Z Series. Power Relay 5. The objects of the declaration described above are in conformity with the relevant Union harmonisation legislation: 2006/95/EC Low Voltage Directive (valid until 19 April 2016) 2014/35/EU Low Voltage Directive (valid from 20 April 2016) 6. References to the relevant harmonised standards used or references to the other technical specifications in relation to which conformity is declared: EN 60947-4-1:2010+A1 Signed and on behalf of: OM RON Corporation Place and date of issue: Kyoto. Japan M ()..r . .. Signature: Name: Junta Tsujinaga Function: Industrial Automation Company. Components Division. Manager Name and address of contact in EU OMRON Europe B.V. Quality & Environment Department Attn : J.J.P.W. Vogelaar. European Quality & Environment Manager Zilverenberg 2. 5234 GM . 's-Hertogenbosch. The Netherlands 112

om Ron · No. ERYT030D Original om Ron EU DECLARATION OF CONFORMITY 1. Product Models/Products: Power Relay G7Z Series 2. Name and address of the manufacturer:

Embed Size (px)

Citation preview

No. ERYT030D

Original om Ron EU DECLARATION OF CONFORMITY

1. Product Models/Products:

Power Relay G7Z Series

2. Name and address of the manufacturer:

OMRON Corporation

Shiokoji Horikawa Shimogyo-Ku. Kyoto. 600-8530 Japan

3. This declaration of conformity is issued under the sole responsibility of the

manufacturer.

4. Objects of the declaration:

G7Z Series. Power Relay

5. The objects of the declaration described above are in conformity with the

relevant Union harmonisation legislation:

2006/95/EC Low Voltage Directive (valid until 19 April 2016)

2014/35/EU Low Voltage Directive (valid from 20 April 2016)

6. References to the relevant harmonised standards used or references to the

other technical specifications in relation to which conformity is declared:

EN 60947-4-1:2010+A1

Signed and on behalf of: OM RON Corporation

Place and date of issue: Kyoto. Japan M ()..r . .. ~. ~t--6 Signature: ~ c)"l~7 Name: Junta Tsujinaga

Function: Industrial Automation Company. Components Division.

Manager

Name and address of contact in EU

OMRON Europe B.V.

Quality & Environment Department

Attn: J.J.P.W. Vogelaar. European Quality & Environment Manager

Zilverenberg 2. 5234 GM. 's-Hertogenbosch. The Netherlands

112

doug.barnett
Highlight

No. ERYT030D

G7Z series Types List for EC Directive

G7Z-4A

G7Z-3A1B G7Z-2A2B G73Z-20Z Auxiliary Contact Block G73Z-11Z Auxiliary Contact Block G73Z-02Z Auxiliary Contact Block

2/2

doug.barnett
Highlight

Zertifikat Certificate

Zertifikat Nr. Certificate No. R 50079155

Ihr Zeichen Clie11t Reference 16TI072

Blatt Page 0008

Unser Zeichen Our Rejere11ce ZJL-CSH- 12304563 007

Awstellungsdatum

28.06.2016

Fertigungsstiitte Mallufacturillg Pla11t

A .. \!)

TUVR hei nland

Date of Issue (daylmolyr)

Genehmigungsinhaber license Holder Omron Corp. Shiokoji Horikawa, Shimogyo-ku Kyoto-shi, Kyoto

OMRON RELAY & DEVICES Corporation Takeo Factory 11000 Kobaru

600-8530 Japan Nakano, Asahi-cho Takeo-shi, Saga 843-0002 Japan

Priifzeichen Test Mark Gepriift nach Tested ace. to

A. TOVRhelnland

Bauart gaprDfl

Slcherhelt llegafmiBTge Produktlant· Qberwachung

www.tuv,c::om ID 2QQOOOOOOO

EN 60947-4-1:2010+Al

Zertitiziertes Produkt (Geriiteidentifikation) Certified Product (Product lde~ztiflcatioJz)

Schutz Electromagnetic Contactor, as page 0001

Addition

Type Designation; G7Z-II - UB-IV II = 4A,3A1B,2A2B IV = optional (see Appendix 1.2)

Model variant with 55 mm mounting hole distance.

ANLAGE (Appendi x): 1.2 Dem Zerrifilwt liegt rmsere Prilf und Zertijizienmgsordmmg tugnmde rmd es IJestlttigt die Konfonnitlit des Prodrrktes mit den oben ge11atr1rten Standtmls rmd Priifgntll(l/agtm. Z~tsiltzliche Aliforclenmgen

Lizenzentgelte • Einheit Lice11se Fee· U1zit

l

1

irr Ulndem, in dtnerr das Prodrrlct ill Verlcehr gebrocht werdttl soli, milsst/1 trrslttzlich bttrachtet IVtrdtlr. Dit Htrstellung des urtijiderten Produlctes wlrd ilbemacht.

Zertifizierungsstelle

This certificate is basetl on our Testing ami CtrtijicatiotJ Regulation and states the corifonniry of the product witllthe standards and testing rtquirtmttlls as indicated above. Any additional requiremellts in countries where the product is going to bt marketed have to be corrsiderttl additionally. The mamrfactllring of the certified prodrrct ts subject to sutVeillanct,

TUV Rheinland LGA Products GmbH· Tillystra8e 2-90431 Niirnberg Tel.: (+49/221)806- 13 71 e-mail: [email protected] Fax: (+49/221)8 06- 39 35 hltp:/lwww.tuv.com/safety DipJ •• Ing. (FH) F. Becker

doug.barnett
Highlight
doug.barnett
Highlight

Zertifikat Certificate

Zertifikat Nr. Certificate No R 50079155

Ihr Zeichen Client Reference

13TI118

BlaUPffge 0007

Unser Zekben Our Reference

ZJL-CSH- 12304563 006 Ausstellungsdatum

17.03.2015

A , .. ~

TUVRheinland

Date of Issue (daylmolyr)

Genehmigungsinhaber License Holder Omron Corp.

Fertigungsstiitte Manufacturing Plant

Shiokoji Horikawa, Shimogyo-ku Kyoto-shi, Kyoto

OMRON RELAY & DEVICES Corporation Takeo Factory 11000 Kobaru

600-8530 JAPAN Nakano, Asahi-cho Takeo-shi, Saga 843-0002 JAPAN

Priifzeicben Test Mark Gepriift nacb Tested ace. to Bauart gaprllft Slchemelt Regelml&lge Produkll<lnt· Dberw•c""ng

EN 60947-4-1:2010+Al

Zertifiziertes Produkt Certified Product

(Geriteidentifikation) (Product ldentificfftion)

Schutz Electromagnetic Contactor, as page 0001

Addition

Type Designation: G73Z-20Z-R G73Z-l1Z-R G73Z-02Z-R

Number of Poles: 2 (2NO, Utilization Category: AC-15 Rated Operational Voltage: 440V Rated Operational CUrrent: 0,3A Rated Frequency: 50/60Hz Rated Impulse W~thstand Voltage: 6kV Pollution Degree: 3

lNO+lNC, DC-13 llOV 0,3A

Mirror Contacts: all NC-contacts

2NC)

Dem Zurifikat liegt unsere PrlJf- und artifkienmgsordnung r.ugnmdt und es btstiitigt dit Konformitlit des Prodult.tes mit den oben genannten Standards und Priifgrvndlagen. Zu.rlitz/iche Anfordtrungen in Liindem, in de~n das Produlct in Verlci:hr gebracht werden sol~ miissen tusiilllich betrachttt wtmkn. Die Herstellung des zertifitierten Prodult.tes wird iibuwaclrt. This certificate is bastd on our Testing and Certification Reg11lation and sUltes tht confonnily of the product with tM standards and ttsting requirements as indicattd abovt. Any additional requirements in countries where the product is going to bt marketed have to bt considered additionally The manufacturing of tht certified product is subject to surveillance.

TUV Rheinland LGA Products GmbH • Tillystra8e 2 - 90431 Nurnberg

Ll : (+491221)8 06 • 13 71 e -mail: cert-validity@detuv com : (+49.1221)8 06- 39 35 http://www tuv.comfsafety

-..a- I • ~. _," •• ,.., .... ~-.. -.- ... ... . .. ,""'~";;o:e•Mt

Lizenzentgelte - Einheit License Fee- Unit

l

Zertifizierongsstelle

:&b t;t0_ Vilmos Sztaroveczki

doug.barnett
Highlight

Zertifikat Certificate

Zertif'tkat Nr. Certificate No. R 50079155

lbr Zeichen Client Reference

12RI115

Blatt Page 0006

Unser Zeichen Our Reference

ZJL-CSH- 12304563 005 Ausstellungsdatum

04.12 . 2012

Fertigungsstatte Manufacturing Plant

A .. QY

TUVRheinland

Date of Issue (day/molyr)

Genehmigungsinhaber License Holder Omron Corp. Shiokoji Horikawa, Shimogyo-ku Kyoto-shi, Kyoto

OMRON RELAY & DEVICES Corporation Takeo Factory 11000 Kobaru

600-8530 JAPAN Nakano, Asahi-cho Takeo-shi, Saga 843-0002 JAPAN

Priifzeichen Test Mark Gepriift nach Tested ace. to

• BAUART GEPR0FT

• TYPE APPROVED

EN 60947-4-1:2010+A1

Zertifiziertes Produkt Certified Product

(Gerateidentifikation) (Product Identification)

Schutz Electromagnetic Contactor, as page 0001

Change

Test Require ment: EN 6 0947 - 4-1: 200l+Al +A2

c hange d to: (s ee above )

Dem Zertijikat liegt unsere Priif- und Zertijizierungsordnung zugrunde und es bestiitigt die Konformitiit des Produktes mit den oben genannten Standards und Priifgrundlagen. Zusiitzliche Anforderungen in Uindem , in denen das Produkt in Verkehr gebracht werden soli, miissen zusiitzlich betrachtet werden. Die Herstellung des zertijizierten Produktes wird iibenvacht. This certificate is based on our Testing and Certification Regulation and states the conformity of the product with the standards and testing requirements as indicated above. Any additional requirements in countries where the product is going to be marketed have to be considered additionally. The manufacturing of the certified product is subject to surveillance.

TUv Rheinland LGA Products GmbH - Tillystra6e 2- 90431 Niirnberg Tel.: (+49/221)8 06 - 13 71 e-mail: [email protected] Fax: (+49/221)8 06-39 35 http:l/www.tuv.com/safety

Lizenzentgelte - Einheit License Fee- Unit

Zertifizierungsstelle

Dipl.-Ing. (FH) J. Taylor

·z t··f·k t· .·.·· <er'l'l .:a··

Zertifikat Nr. Certificate No. R 5007.9155

Certificate

Blatt Page 0001

Ihr Ze~cben Client Reft}tence 05'TKO€i0

Unser Zeichen Our Reference ZO-CSH- 12304563 001

Aus tellungsdatum

09.03.2006

Genebmigungsinl1aber License Holqer Omron CoJrp. Shiokoji Horikawa , Shimogyo-ku Kyoto-.shi, Kyoto 600-8530 · japan

FertigllllgssHitte Manufacturing Plant Omron Takeo Co., Ltd. 11000 Kobaru Nakano, Asahi-cho Takeo-shi, saga 843-0002 Japan

Priifzeichen Test Mark Gepriift nach Tested ace. to

BAoUART GEPRUFT

ruv TYPE RhelniMd. APPROVED

Product Safe ty

EN 60947-4-1:2001+Al+A2

•• TUV

Date of Issue (daylmo/yr)

Zertifiziertes Produkt Catified Product

(Gerateidentifikation) (Product Identification)

Lizenzentgelte - Einheit License Fee - Unit

·schutrz Electromagnetie Contactor

Type Desigh:ation G7Z-II-III II = 4A, 3A1B or 2A2B III: optional (see Appendix 1)

Ntunber of Poles 4 (4NO, 3N0+1NC, 2N0+2NC)

NO~ contact A.C-1 AC-3 DC-1 440V 440V llOV

Utilization Category Rated O]!ferational Voltage Rated Gpera.tional Current Rated Frequency

40A 16A 50/60Hz

Voltage: 6kV Rated Imp.ulse· Withstand PoJ:hrtion Degree

5A

Mir:r:or Contacts

ANLAGE (Appendix) 1

3 available with auxiliary G73Z-11Z,

NC - contact AC-1 DC-1 440V llOV 25A SA

Tiiv Rheinland Product Safety GmbH, Am Grauen_Stetn, D-51105 ~"'-

Tel. :( +4912i<J.)8 06- p 71 Fax:(+491221)8 06-39 35 e-mail: [email protected]

Zertifizierungsstelle

5 l

6

doug.barnett
Highlight

Zertifikat

Zertifikat Nr. Certificate No. R 500:7915.5

Certificate

Blatt Page 00.02

Ihr Zeicllcn Client Ref-erence

05TK0 60 Unser Zeichen Our Reference

ZO-CSH- 12304563 001 A usstellungsdatum

09.03.2006

Genehmigungsin:liaber Licertse HofMr Omron Corp. Shiokoji Horikawa, Shimogyo-ku Kyoto-shi, Kyoto 600-8530 Japan

Fertigungsstatte Manufacturing Plant Omron Takeo Co., Ltd. 11000 Kobaru Nakano, Asahi-cho Takeo-shi, Saga 843-0002 Japan

P!·iifzeichen Test Mark Gepriift nach Tested ace. to

B:llUA.RT GEPR0FT

TOV TYPE Rheinland APPROVED

1Produet Safety

EN 60947-4-1:200l+Al+A2

•• TUV

Date of Issue (day!molyr)

Zertifiziertes Produkt (Geratcidentifikation) Certified Product (Product Identification)

Lizenzentgelte - Einheit License Fee - Unit

Schiltz Electromagne'tic Contactor

Additio~ (Auxiliary Contact Block) :

Type IDesignation G73Z-II-III II = 20Z, llZ or 02Z III: optional (see Appendix 1)

1e:r of Poles 2 (2N0,1N0+1NC, 2NC)

Utilization Category Rated Operational Voltage Rated operational Cur~ent Rated Freqv.ency Rated Impulse Withstand Voltage: Pollution Degree Mir:r:0r Contacts

ANLAGE (Appendix) : 1

AC-15 DC-13 440V llOV Q,5A O,SA 50/60Hz 6kV 3 all NC-contacts

D.i!m Zertijikat liegt unsere Prtlf- und Zerti[11.ierungsordmmg zugrunde. IJas Produkt_entspricht den o.g .. Anforder_u,gen, die flerstelltmg wird flbenvacht. 11zis certificate. is based 011 our Testing and Certification Regulation. The product fulfills aboveomeJztioned-req!liremellls, the produejion is subject to surveillance.

TUv Rh~and ~oductSafety GmbH, Am GrauenStein, D-51105 Koln

Tel.:(+49/2~l)8 06 -- ~3 71 Fax:{.+491221)8 06-39 3$ e-mail: [email protected]

2

2

Zertifizierungsstelle

doug.barnett
Highlight

5/30/2018 NLDX2.E41643 - Motor Controllers, Magnetic - Component

http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=NLDX2.E41643&ccnshorttitle=Motor+Controllers,+Magnetic+-+Component&obj

NLDX2.E41643 Motor Controllers, Magnetic - Component

If you notice a change to your NLDX2 Listing Card, click here to learn more.

Page Bottom

Motor Controllers, Magnetic - Component See General Information for Motor Controllers, Magnetic - Component OMRON CORP E41643SAFETY STANDARDS GROUPIAB GLOBAL QUALITY CENTERSHIOKOJI HORIKAWASHIMOGYO-KU, KYOTO 600-8530 JAPAN

Investigated to ANSI/UL 508

Auxiliary Contact Modules Model(s) G73Z followed by -20Z, -11Z and -02Z, may be followed by -R, may be followed by additional letter(s)and/or number(s)

Contactor Model(s) G7Z followed by -4A, -3A1B and -2A2B, may be followed by -UB, may be followed by -4, may be followed by additionalletter(s) and/or number(s).

Contactor and Auxiliary Contact Module combination Model(s) G7Z, followed by -4A, -3A1B and -2A2B , followed by -20Z, -11Z and -02Z,may be followed by -R, may be followed by additional letter(s) and/or number(s).

For use in industrial applications, open type Model(s) +G2R, with suffix K, followed by -1 or -2, may be followed by A, may be followed byASI, may be followed by AP or AUL, may be followed by Y90*, followed by 5 thru 48 Vdc.

+G6B, may be followed by K or U, followed by -1114 followed by P or C, may be followed by -FD, followed by -US, may be followed by -3 thru -24Vdc, may be followed by additional letter(s) and/or number(s).

G2R, followed by -1 or -2, may be followed by A or B, may be followed by Z, may be followed by 4, may be followed by -E*, may be followed by -H, -H2 or -H3, may be followed by -AS, -ASI or -AS-TB, may be followed by -AP or -AUL, may be followed by -T130 or -T155, may be followed by-Y90*, followed by 3 thru 120 Vdc or 6 thru 240 Vac.

G2R, followed by -1 or -2, may be followed by A, may be followed by 3, followed by -S or -T, may be followed by N, D or ND, may be followed byI, may be followed by additional number(s) and/or letter(s), may be followed by -AP#, may be followed by -T130, may be followed by additionalnumber(s) and/or letter(s), may be followed by (S), may be followed by (L), followed by 5 through 110VDC or 6 through 240VAC.

G2R, followed by G, followed by 2, followed by A, followed by 4, may be followed by ANI, may be followed by optional letter(s) and/or number(s),may be followed by -T155, followed by 5 to 24 V dc.

G2R-UA-006027, G2R-UA-006028, G2R-UA-006029, G2R-UA-006030, G2R-UA-006031, G2R-UA-006032, G2R-UA-006033, G2R-UA-006034,G2R-UA-006035, G2R-UA-006036, G2R-UA-006037, G2R-UA-006038, G2R-UA-006039, G2R-UA-006040, G2R-UA-006043, G2R-UA-006044,G2R-UA-006049, G2R-UA-006050, G2R-UA-006051, G2R-UA-006053, G2R-UA-006054, G2R-UA-006055, G2R-UA-006056, G2R-UA-006057,G2R-UA-006059, G2R-UA-006060, G2R-UA-006061, G2R-UA-006062, G2R-UA-006065, G2R-UA-006066, G2R-UA-006067, G2R-UA-006072,G2R-UA-006073, G2R-UA-006074, G2R-UA-006075, G2R-UA-006078

G2RL, followed by 1 or 2, may be followed by A, may be followed 4, may be followed by TP7 or TP5, may be followed by H, may be followed by E,may be followed by ASI, may be followed by CF, may be followed by AP, may be followed by CV, may be followed by HA, may be followed by -CN*, followed by 3 through 60 Vdc.

G5LE-UA-006073, G5LE-UA-006100, G5LE-UA-006103, G5LE-UA-006104, G5LE-UA-006107, G5LE-UA-006108, G5LE-UA-006111, G5LE-UA-006112, G5LE-UA-006113

GR2L-14-E DC5, GR2L-14-E DC24, GR2L-14-E DC48, GR2L-14-E-CF DC12, GR2L-14-E-CF DC24.

MM3-UA*

Industrial applications Model(s) +G6C, may be followed by K or U, followed by -1 or -2, followed by 1, followed by 1, followed by 4 or 7,followed by P or C, may be followed by -FD, may be followed by -1, may be followed by letter(s) and/or number(s), may be followed by letter(s)and/or number(s), followed by 3 Vdc thru 48 Vdc.

+G6C-UA-006002, +G6C-UA-006003, +G6C-UA-006004, +G6C-UA-006005, +G6C-UA-006006, +G6C-UA-006007

doug.barnett
Highlight
doug.barnett
Highlight
doug.barnett
Highlight

5/30/2018 NLDX2.E41643 - Motor Controllers, Magnetic - Component

http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=NLDX2.E41643&ccnshorttitle=Motor+Controllers,+Magnetic+-+Component&obj

+LY, followed by 3 or 4, may be followed by F or S, may be followed by I2 or I4, may be followed by -D, N or N-D2, may be followed by -0, maybe followed by -C, may be followed by -30, may be followed by -QSK1, may be followed by -QSK2, followed by 6V AC thru 240V AC or 6V DC thru125V DC.

G8P-1111P-US, LY3-UA-006118, LY3-UA-006119, LY3-UA-006120, LY3-UA-006121, LY3-UA-006122, LY3-UA-006123, LY3-UA-006124, LY3-UA-006125, LY3-UA-006126, LY3-UA-006127, LY3-UA-006128, LY4-UA-006348, LY4-UA-006379, LY4-UA-006383

Industrial applications, some ratings non-industrial only Model(s) +G4W, followed by -1 or -2, followed by 1 or 2, followed by 1, followedby 2 or 4, followed by P, may be followed by -FD* or -ACD*, may be followed by a -TV5, -TV8 or TV-10, may be followed by -HP, may be followedby -ARC, may be followed by -T130*, followed by DC5 thru 100.

+G5R5, may be followed by A or E, may be followed by C, may be followed by additional letter(s) and/or number(s).

+G6B, may be followed by a K or U, followed by -1 or -2, followed by 0, 1 or 2, followed by 1, 7 or 8, followed by 4, 2 or 7, followed by P or C,may be followed by -FD, may be followed by 1, may be followed by -ND, may be followed by US or letter(s) and/or number(s), may be followedby letter(s) and/or number(s), followed by -3 Vdc thru -48 Vdc.

+G7L, followed by -1A or -2A, followed by -B, -P or -T, may be followed by UB, may be followed by J, may be followed by -ACD, may be followedby one or more letters and/or up to two digits, may be followed by one or more letters and/or up to two digits, may be followed by T130*, CB* orPV, followed by coil voltage.

+G7T-1112S-12 Vdc thru +G7T-1112S-125 Vdc, +G7T-1112S-24 Vac thru +G7T-1112S-240 Vac, +G7T-1122S-12 Vdc thru +G7T-1122S-125Vdc, +G7T-1122S-24 Vac thru +G7T-1122S-125 Vac

G4A, followed by 1, followed by A, may be followed by P, C or TC, may be followed by E, may be followed by T130 or CF, may be followed by CN,may be followed by NV, may be followed by HA, may be followed by DK, TRC, or additional letters and/or numbers, followed by coil rating.

G4AN-1A*, G4AS-1A*

G5RL, may be followed by U or K, followed by 1, may be followed by A, may be followed by 4, may be followed by P5 or E, may be followed by LN,may be followed by HA, may be followed by ?TV8, may be followed by additional letter(s) and/or number(s).

G6RL, followed by 1, may be followed by A, may be followed by 4, may be followed by SR, may be followed by ASI*, may be followed by HA,followed by 3 Vdc thru 48 Vdc.

G7J, followed by 1A, -1A1B, -1A2B, -2A, -2A1B, -2A2B, -3A, -3A1B or -4A, followed by -B, -BZ, -P, -PD, -PZ, -T or -TZ, may be followed by UB,may be followed by -CB, may be followed by letter and/or up to two or three digits numbers.

LY, may be followed by Q, followed by 1 or 2, may be followed by Z, may be followed by F or S, may be followed by I4 or I, may be followed by -CR, -D, N, N-CR or N-D2, may be followed by -0 or -T2, may be followed by -CU* or -C*, may be followed by -10, -20 or -L, may be followed by -T130, may be followed by -AP*, followed by 6V AC thru 240V AC or 6V DC thru 125V DC.

LY1-UA-006001, LY1-UA-006004, LY1-UA-006063, LY1-UA-006064, LY1-UA-006065, LY1-UA-006066, LY1-UA-006067, LY1-UA-006068, LY1-UA-006069, LY1-UA-006070, LY1-UA-006071, LY1-UA-006072, LY1-UA-006347, LY1-UA-008006, LY2-UA-006223, LY2-UA-006243, LY2-UA-006246,LY2-UA-006276, LY2-UA-006277, LY2-UA-006281, LY2-UA-006282, LY2-UA-006349, LY2-UA-006530, LY2-UA-006630, LYQ2-UA-006284, LYQ2-UA-006288, LYQ2-UA-006350

Magnetic Motor Controllers Model(s) G5LE followed by -1, may be followed by A or B, may be followed by 4, may be followed by -R, may befollowed by -ASI, -AP3, or -ASI-AP3, may be followed by -CF or -HA, may be followed by -G or -E, may be followed by -36, -55, or -60, may befollowed by additional letters(s) and/or number(s), followed by coil voltage rating 3 through 48V dc for standard G5LE, or 5 through 24V dc for -Etype, or 9 through 24 V dc for -G type.

G5LE, followed by -UA , followed by -006073, -006100, -006103, -006104, -006107, -006108, -006111, -006112, and -006113.

Non-industrial, open type Model(s) G5D, followed by -11 or -22, followed by 4, followed by 2, may be followed by 3, followed by T, followed byUS, may be followed by letters and/or numbers up to two digits.

Open type, Industrial, Motor controllers Model(s) G2R-UA-006047, G2R-UA-006048, G2R-UA-006052

G7L-UA followed by -006000, -006002, -006003, -006005, -006006, -006007, -006008, -006009, -006010, -006011, -006012, -006013,-006014, or -006015.

LY1, followed by -UA, followed by 006376, 006380, 006677, 006679, 006681, 006682, 006683

LY2, followed by -UA, followed by 006244, 006371, 006377, 006397, 006540, 006541, 006542, 006543, 006544, 006545, 006546, 006547,006647, 006653, 006689, 006690, 006691, 006692, 006693, 006694, 006695, 006696, 006697, and 006705

LY3, followed by -UA, followed by -006548 through -006555, -006660, -006706, or -006708 through -006711

LY4, followed by -UA, followed by -006556 through -006563, -006666, -006714, -006716, -006718, or -006719

Relays Model(s) G2RV Series; followed by 1; followed by S; may be followed by I; may be followed by -AP; may be followed by additional lettersand/or numbers ; maybe followed by 11VDC through 48VDC.

Socket types, use for MP or MP2P Model(s) PP10

* - May be followed by -R, may be followed by additional letter(s) and/or number(s).

+ - UL Recognized products must bear the Recognition mark.

Marking: Company name or tradename "OMRON" and model designation.Last Updated on 2018-05-23

Questions? Print this page Terms of Use Page Top

5/30/2018 NLDX8.E41643 - Motor Controllers, Magnetic Certified for Canada - Component

http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=NLDX8.E41643&ccnshorttitle=Motor+Controllers,+Magnetic+Certified+for+Cana

NLDX8.E41643 Motor Controllers, Magnetic Certified for Canada - Component

If you notice a change to your NLDX8 Listing Card, click here to learn more.

Page Bottom

Motor Controllers, Magnetic Certified for Canada - Component See General Information for Motor Controllers, Magnetic Certified for Canada - Component OMRON CORP E41643SAFETY STANDARDS GROUPIAB GLOBAL QUALITY CENTERSHIOKOJI HORIKAWASHIMOGYO-KU, KYOTO 600-8530 JAPAN

Investigated to CAN/CSA C22.2 No. 14-13

Contactor Model(s) G7Z followed by -4A, -3A1B and -2A2B, may be followed by -UB, may be followed by -4, may be followed by additionalletter(s) and/or number(s).

Contactor and Auxiliary Contact Module combination Model(s) G7Z, followed by -4A, -3A1B and -2A2B , followed by -20Z, -11Z and -02Z,may be followed by -R, may be followed by additional letter(s) and/or number(s).

For use in industrial applications, open type Model(s) G2R, followed by -1 or -2, may be followed by A, may be followed by 3, followed by -Sor -T, may be followed by N, D or ND, may be followed by I, may be followed by additional number(s) and/or letter(s), may be followed by -AP#,may be followed by -T130, may be followed by additional number(s) and/or letter(s), may be followed by (S), may be followed by (L), followed by5 through 110VDC or 6 through 240VAC.

G2R, followed by G, followed by 2, followed by A, followed by 4, may be followed by ANI, may be followed by optional letter(s) and/or number(s),may be followed by -T155, followed by 5 to 24 V dc.

G2RL, followed by 1 or 2, may be followed by A, may be followed 4, may be followed by TP7 or TP5, may be followed by H, may be followed by E,may be followed by ASI, may be followed by CF, may be followed by AP, may be followed by CV, may be followed by HA, may be followed by -CN*, followed by 3 through 60 Vdc.

GR2L-14-E DC5, GR2L-14-E DC24, GR2L-14-E DC48, GR2L-14-E-CF DC12, GR2L-14-E-CF DC24.

Magnetic Motor Controllers Model(s) G5LE followed by -1, may be followed by A or B, may be followed by 4, may be followed by -R, may befollowed by -ASI, -AP3, or -ASI-AP3, may be followed by -CF or -HA, may be followed by -G or -E, may be followed by -36, -55, or -60, may befollowed by additional letters(s) and/or number(s), followed by coil voltage rating 3 through 48V dc for standard G5LE, or 5 through 24V dc for -Etype, or 9 through 24 V dc for -G type.

G5LE, followed by -UA , followed by -006073, -006100, -006103, -006104, -006107, -006108, -006111, -006112, and -006113.

Open type, Industrial, Motor controllers Model(s) G7L-UA followed by -006000, -006002, -006003, -006005, -006006, -006007, -006008,-006009, -006010, -006011, -006012, -006013, -006014, or -006015.

LY1, followed by -UA, followed by 006376, 006380, 006677, 006679, 006681, 006682, 006683

LY2, followed by -UA, followed by 006244, 006371, 006377, 006397, 006540, 006541, 006542, 006543, 006544, 006545, 006546, 006547,006647, 006653, 006689, 006690, 006691, 006692, 006693, 006694, 006695, 006696, 006697, and 006705

LY3, followed by -UA, followed by -006548 through -006555, -006660, -006706, or -006708 through -006711

LY4, followed by -UA, followed by -006556 through -006563, -006666, -006714, -006716, -006718, or -006719

Investigated to CAN/CSA C22.2. No. 14-10

Auxiliary Contact Modules Model(s) G73Z followed by -20Z, -11Z and -02Z, may be followed by -R, may be followed by additional letter(s)and/or number(s)

For use in industrial applications, open type Model(s) +G2R, with suffix K, followed by -1 or -2, may be followed by A, may be followed byASI, may be followed by AP or AUL, may be followed by Y90*, followed by 5 thru 48 Vdc.

doug.barnett
Highlight
doug.barnett
Highlight

5/30/2018 NLDX8.E41643 - Motor Controllers, Magnetic Certified for Canada - Component

http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=NLDX8.E41643&ccnshorttitle=Motor+Controllers,+Magnetic+Certified+for+Cana

G2R, followed by -1 or -2, may be followed by A or B, may be followed by Z, may be followed by 4, may be followed by -E*, may be followed by -H, -H2 or -H3, may be followed by -AS, -ASI or -AS-TB, may be followed by -AP or -AUL, may be followed by -T130 or -T155, may be followed by-Y90*, followed by 3 thru 120 Vdc or 6 thru 240 Vac.

G2R-UA-006027, G2R-UA-006028, G2R-UA-006029, G2R-UA-006030, G2R-UA-006031, G2R-UA-006032, G2R-UA-006033, G2R-UA-006034,G2R-UA-006035, G2R-UA-006036, G2R-UA-006037, G2R-UA-006038, G2R-UA-006039, G2R-UA-006040, G2R-UA-006043, G2R-UA-006044,G2R-UA-006049, G2R-UA-006050, G2R-UA-006051, G2R-UA-006053, G2R-UA-006054, G2R-UA-006055, G2R-UA-006056, G2R-UA-006057,G2R-UA-006059, G2R-UA-006060, G2R-UA-006061, G2R-UA-006062, G2R-UA-006065, G2R-UA-006066, G2R-UA-006067, G2R-UA-006072,G2R-UA-006073, G2R-UA-006074, G2R-UA-006075, G2R-UA-006078, G5LE-UA-006073, G5LE-UA-006100, G5LE-UA-006103, G5LE-UA-006104,G5LE-UA-006107, G5LE-UA-006108, G5LE-UA-006111, G5LE-UA-006112, G5LE-UA-006113

Industrial applications Model(s) +G6C, may be followed by K or U, followed by -1 or -2, followed by 1, followed by 1, followed by 4 or 7,followed by P or C, may be followed by -FD, may be followed by -1, may be followed by letter(s) and/or number(s), may be followed by letter(s)and/or number(s), followed by 3 Vdc thru 48 Vdc.

+G6C-UA-006002, +G6C-UA-006003, +G6C-UA-006004, +G6C-UA-006005, +G6C-UA-006006, +G6C-UA-006007

+LY, followed by 3 or 4, may be followed by F or S, may be followed by I2 or I4, may be followed by -D, N or N-D2, may be followed by -0, maybe followed by -C, may be followed by -30, may be followed by -QSK1, may be followed by -QSK2, followed by 6V AC thru 240V AC or 6V DC thru125V DC.

LY3-UA-006118, LY3-UA-006119, LY3-UA-006120, LY3-UA-006121, LY3-UA-006122, LY3-UA-006123, LY3-UA-006124, LY3-UA-006125, LY3-UA-006126, LY3-UA-006127, LY3-UA-006128, LY4-UA-006348, LY4-UA-006379, LY4-UA-006383

Industrial applications, some ratings non-industrial only Model(s) +G4W, followed by -1 or -2, followed by 1 or 2, followed by 1, followedby 2 or 4, followed by P, may be followed by -FD* or -ACD*, may be followed by a -TV5, -TV8 or TV-10, may be followed by -HP, may be followedby -ARC, may be followed by -T130*, followed by DC5 thru 100.

+G6B, may be followed by a K or U, followed by -1 or -2, followed by 0, 1 or 2, followed by 1, 7 or 8, followed by 4, 2 or 7, followed by P or C,may be followed by -FD, may be followed by 1, may be followed by -ND, may be followed by US or letter(s) and/or number(s), may be followedby letter(s) and/or number(s), followed by -3 Vdc thru -48 Vdc.

+G7L, followed by -1A or -2A, followed by -B, -P or -T, may be followed by UB, may be followed by J, may be followed by -ACD, may be followedby one or more letters and/or up to two digits, may be followed by one or more letters and/or up to two digits, may be followed by T130*, CB* orPV, followed by coil voltage.

G4A, followed by 1, followed by A, may be followed by P, C or TC, may be followed by E, may be followed by T130 or CF, may be followed by CN,may be followed by NV, may be followed by HA, may be followed by DK, TRC, or additional letters and/or numbers, followed by coil rating.

G4AN-1A*, G4AS-1A*

G5RL, may be followed by U or K, followed by 1, may be followed by A, may be followed by 4, may be followed by P5 or E, may be followed by LN,may be followed by HA, may be followed by ?TV8, may be followed by additional letter(s) and/or number(s).

G6RL, followed by 1, may be followed by A, may be followed by 4, may be followed by SR, may be followed by ASI*, may be followed by HA,followed by 3 Vdc thru 48 Vdc.

LY, may be followed by Q, followed by 1 or 2, may be followed by Z, may be followed by F or S, may be followed by I4 or I, may be followed by -CR, -D, N, N-CR or N-D2, may be followed by -0 or -T2, may be followed by -CU* or -C*, may be followed by -10, -20 or -L, may be followed by -T130, may be followed by -AP*, followed by 6V AC thru 240V AC or 6V DC thru 125V DC.

LY1-UA-006001, LY1-UA-006004, LY1-UA-006063, LY1-UA-006064, LY1-UA-006065, LY1-UA-006066, LY1-UA-006067, LY1-UA-006068, LY1-UA-006069, LY1-UA-006070, LY1-UA-006071, LY1-UA-006072, LY1-UA-006347, LY1-UA-008006, LY2-UA-006223, LY2-UA-006243, LY2-UA-006246,LY2-UA-006276, LY2-UA-006277, LY2-UA-006281, LY2-UA-006282, LY2-UA-006349, LY2-UA-006530, LY2-UA-006630, LYQ2-UA-006284, LYQ2-UA-006288, LYQ2-UA-006350

Open type, Industrial, Motor controllers Model(s) G2R-UA-006047, G2R-UA-006048, G2R-UA-006052

Relays Model(s) G2RV Series; followed by 1; followed by S; may be followed by I; may be followed by -AP; may be followed by additional lettersand/or numbers ; maybe followed by 11VDC through 48VDC.

* - May be followed by -R, may be followed by additional letter(s) and/or number(s).

+ - UL Recognized products must bear the Recognition mark.

Marking: Company name or tradename "OMRON" , model designation and the Recognized Component Mark for Canada, .Last Updated on 2018-05-23

Questions? Print this page Terms of Use Page Top

© 2018 UL LLC

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufacturedunder UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-UpService. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The GuideInformation, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleadingmanner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permissionfrom UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the followingformat: "© 2018 UL LLC".

OMRON CANADA, INC. • HEAD OFFICEToronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron247.com

OMRON ELECTRONICS DE MEXICO • HEAD OFFICEMéxico DF • 52.55.59.01.43.00 • 01-800-226-6766 • [email protected]

OMRON ELECTRONICS DE MEXICO • SALES OFFICEApodaca, N.L. • 52.81.11.56.99.20 • 01-800-226-6766 • [email protected]

OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICESão Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br

OMRON ARGENTINA • SALES OFFICECono Sur • 54.11.4783.5300

OMRON CHILE • SALES OFFICESantiago • 56.9.9917.3920

OTHER OMRON LATIN AMERICA SALES54.11.4783.5300

Authorized Distributor:

J89I-E-01 11/14 Note: Specifications are subject to change. © 2014 Omron Electronics LLC Printed in U.S.A.

Printed on recycled paper.

Automation Control Systems• Machine Automation Controllers (MAC) • Programmable Controllers (PLC) • Operator interfaces (HMI) • Distributed I/O • Software

Drives & Motion Controls • Servo & AC Drives • Motion Controllers & Encoders

Temperature & Process Controllers • Single and Multi-loop Controllers

Sensors & Vision• Proximity Sensors • Photoelectric Sensors • Fiber-Optic Sensors• Amplified Photomicrosensors • Measurement Sensors• Ultrasonic Sensors • Vision Sensors

Industrial Components • RFID/Code Readers • Relays • Pushbuttons & Indicators• Limit and Basic Switches • Timers • Counters • Metering Devices • Power Supplies

Safety • Laser Scanners • Safety Mats • Edges and Bumpers • Programmable Safety Controllers • Light Curtains • Safety Relays • Safety Interlock Switches

OMRON AUTOMATION AND SAFETY • THE AMERICAS HEADQUARTERS • Chicago, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com

OMRON EUROPE B.V. • Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. • +31 (0) 23 568 13 00 • www.industrial.omron.eu