Upload
others
View
4
Download
0
Embed Size (px)
Citation preview
OHL Fault IndicatorsGrid Monitoring Software
А3
А3
Experience. We are active on the energy market since 1991
Innovations and advanced technologies
Our devices installed in 26 countries all
over the world
Confidence of leading companies:
Gazprom, Rosseti, Lukoil, Tatneft,
Surgutneftegaz, Tagraz holding
High quality standards
Sustainable growth
About Company
We independently carry out the development, design, manufacture, installation and commissioning of power- generating
equipment and its technical and service maintenance
А3
Fault indicators for Overhead LinesShort-Circuit and Earth Fault Indicators
Cable fault locatorCommunication unitsDistribution network monitoring system
Control and monitoring devices for substation equipment
Specialized
А3
There are two parts of intelligent management system: OHL and substation equipment:
The monitoring and management complex for overhead line networks based on Lodestar
The system of equipping substations with telecontrolsystems and feeder monitoring devices withemergency processes localization functionality
Intelligent ManagementSystem
А3
Monitoring is a process of on-line continuous overhead lines control in order toobtain timely information about emergency and other processes occurring in the line
Online monitoring reduce your OPEX with automated, detection and analysis of troubles and accurate dispatch of crews
Complex monitoring implies obtaininginformation from various points of thenetwork from intelligent fault indicators
The management is performed bymeans of system retrofitting with remotelycontrolled switches and disconnectors
Online Grid Monitoring
А3Resolves main problems of power distribution network
6-35 kV networks specialities
Low level ofnetworks
automation
Low networks observability
Poor controllability
Insufficient equipment with ASCAPC*
Last implementations
Improvementsof SAIDI andSAIFI reliability indexes
Prompt localization of a fault location
Energyundersupplyreduction,on-line management
Control of unauthorized electricityoutfeed
ASCAPC – automatic system for commercial accounting of power consumption
А3
High-precision sensitive devices with power flow direction detection and eventidentificationThe usage of high-frequency sampling and fault currents and voltages values processingmakes possible to determine transient self-clearing faultsUnique algorithms of current and voltage valuesanalysis provide high sensitivity to an emergencyprocess, enabling to fix fault currents from 0.5 A
Lodestar – innovativemonitoring tools
А3Principle of Lodestars operation
Principle of Lodestars operation is based on sensing the fault current flowing inthe monitored line. The device is triggered upon the detection of a faultycurrent, above the current/time threshold
A current surge between the feeding substation andthe fault location followed by the line switch-offtakes place upon the manifestation of a fault
The path of the fault current from the feedingpoint to the fault location is shown by flashingLEDs and turned swivel. The fault is locatedbetween the last flashing and the firstinactive indicators
А3
Lodestar can be used in:Distribution networks with anoperating voltage of <70 kVSolutions for high voltage classes 115kVRadial linesMultiple circuit linesSWERGrids with any types of neutralgrounding
Lodestar and IKZapplication area
Battery status controlManual reset and test with a magnetLive line installation is possible using a hot stick tool.
Lodestar is designed to be installed on eitherbared or covered conductors up to 40mm external diameters (equivalent to 240mm2with insulation thickness of 7mm ).IKZ-V2 is designed to be installed on any types of poles (concrete, wooden, etc).
А3Lodestar systems in the World
Smart Grid (Ufa) - substation automation system
Bashkirenergo - automation system for 7 PDZs
Romande (Switzerland) -monitoring system for PDZ
Tenago Nasional Berhad (Malaysia) -monitoring system for PDZ
Grid company (Tatarstan) - automation system for PDZ*
PDZ – power distribution zone
А3Optimal solution for anysituation- OHL FI Models
OHL Fault Indicators
Pole-mountable Conductor mounted
Medium voltage class
Radio module GSM/GPRS module
IKZ-V21R IKZ-V21M
IKZ-V23R IKZ-V23M
Medium voltage class High voltage class
CL2HV
CL2HV
No communicationRadio, GSM/GPRS*
communication
CL25 CL25B
CL2B
CL0.5B
CL2
CL0.5
* via communication module
BLE, GSM/GPRS* communication
А3OHL FI IKZ-V2
IKZ-V2 is a pole-mountable fault indicator. It is intended for use in distribution networks1-36kV
IKZ-V2 detects a short circuit at the moment of fault currentflowing in one or several phases with a subsequent voltageswitching off
When a fault is detected IKZ-V2 turnselectromagnetic flag yellow side andtransmits data to dispatching point
Have embedded memory for event logging
Determines permanent and transient faults
Save in log the following information: faultcurrent and fault voltages values, short circuittime, fault type
Can be used only in single circuit lines
А3Device Type IKZ-V21R IKZ-21M IKZ-V23R IKZ-23M
Configuration and ManagementOperating voltage < 70kVMin fault sensing FtG 10АCurrent threshold 10-200А 10-1000АBreaker waiting time (∆t) 0.1 – 300sIndication FlagFault detection:PtPPtG
YesYes
Fault type differentiation No Yes
Configuration Remote Remote, Komorsan Remote Remote,
Komorsan
Communication via Radio module GSM/GPRS module Radio module GSM/GPRS
moduleAdjustable reset time up to 7 days
OthersBattery life 7 yearsNeutral grounding type All
Technical characteristics FI IKZ-V2 range
А3Lodestar CL25 is a conductor mounted fault indicator, which is
used in medium voltage power distribution networks
CL25 dynamically changes the sensitivity based on a load current. It can detect faultswith as little as 25 A phase current when loads are light and automatically increase itstrip threshold to remain secure for up to 700 A loads
Differential Threshold (Automatic adjustable fault current Pickup) and Absolute Threshold
Detects Temporary and Permanent Faults
Indication patterns for each type of a fault. A fault is indicated by LEDs flashing,which provides 360 degrees visibility.
Configuration is done via dipswitches
Best solution for SWER- all units in a kit operate independently
Battery status alarm
Lodestar CL25
А3Model Lodestar CL25Operating voltage <70kVFrequency 50Hz-60HzMin fault sensing 25АAbsolute current threshold 100А, 250А, 500А, 1000АDifferential current threshold 50%, 100%, 200% 25А, 100А, 200А, 500АResponse time/ Inrush resistance 20ms/100msBreaker waiting time (∆t) 200sIndication LEDsFault type detection:PtPPtG
YesYes
Fault phase indication YesCurrent withstand 25kА/500msCommunication NoReset Time, Magnet, Line restorationAdjustable reset time 6, 12, 24, 48 hoursBattery life 10 yearsTemperature -40C0 to + 85С0
Technical characteristics Lodestar CL25
А3LODESTAR CL25B
Lodestar CL25B is equipped with radio module forcommunication with a Remote control
Radio communication is done using Bluetooth Low Energy standart. For data securitydata encryption algorithm is intended.
Due to data transmission function Lodestar CL25B can be connected toa communication unit. As a Remote control any portable device supportingBLE protocol can be used (smartphone, tablet).
Detect a short circuit and earth faults occurring in power distribution networks
Permanent and transient faults are identified separately. Each type of a fault has itsown indication pattern for alarm
Lodestar CL25B saves in memory 25 last events. Event list can be performed on aRemote control display. Each event has detailed information: fault timestamp, min andmax fault currents values, fault type, faulty phase.
А3Technical characteristics Lodestar CL25B
Model Lodestar CL25BOperating voltage <70kVFrequency 45Gz-65GzMin fault sensing 25АAbsolute current threshold 100А - 1000А, step 1АDifferential current threshold 50%, 100%, 200% 25А, 100А, 200А, 500АResponse time/ Inrush resistance 20ms/100msBreaker waiting time (∆t) 200sIndication LEDsFault type detection: PtP
PtGYesYes
Fault phase indication YesCurrent withstand 25kА/500msCommunication ComBox (optional)Radio Bluetooth Low Energy 4.2 (2.4 GHz)Remote (optional) YesMemory 25 eventsReset Time, Magnet, Line restoration, ComAdjustable reset time 1 - 200 hours, step 1hBattery life 15-20 yearsTemperature -40C0 to + 85С0
А3Lodestar CL2
Lodestar CL2 is provided with current and voltage unique measurementalgorithms and outstanding fault detection capabilities. No wrong indication
due to high load or inrush peak current is possible.
Lodestar CL2 operation is based on synchronous current andvoltage measurements of all sensors in a kit. Lodestar unitsA,B,C communicate with each other using a radio signal.
Build-in radio module is used for Lodestarcommunications and data exchange. All settings canbe adjusted via a Remote control or The KomorsanWEB-client software.
Faulty phase indication - different indication patterns for each type of a fault: Detects all types of faults: PtP, PtG, single phase faults, multiple phase faultsDifferentiates transient/permanent faultsIndication with flashing LEDs provides dayand night visibility
А3Technical characteristics Lodestar CL2
Model Lodestar CL2Operating voltage <70kVFrequency 50GzMin fault sensing PtG 4А, but min 4% of Iload
Absolute current threshold 20 – 1000АBreaker waiting time (∆t) 0,5 – 200sInrush resistance 0-200sIndication LEDsFault type detection: PtP
PtGYesYes
Communication ComBox (optional)Fault phase indication YesCurrent withstand 25kА/500msRadio 433,92 GzRemote (optional) YesReset Time, Magnet, Line restoration, ComBoxAdjustable reset time 1h to 7 days (1h to 99hours via Remote)Battery life 7 yearsTemperature -40C0 to + 85С0
А3Lodestar CL2B Lodestar CL2B is equipped with radio module for communication with
a Remote control. Radio communication is done using Bluetooth LowEnergy standart. For data security data encryption algorithm is intended.
Due to data transmission function Lodestar CL2B can be connected to communicationunit. Connection of 18 Lodestar CL2B units (6*3) to one ComBox is possible.
Lodestar CL2B saves in memory 50 last events. Event list can be performed on a Remotecontrol display. Each event has detailed information: fault timestamp, min and max faultcurrents values, fault type, faulty phase.
All settings are done via Remote control or the Komorsan Web-client software (in case ofconnection via ComBox).As a Remote control any portable device supporting BLE protocol can be used(smartphone, tablet).
For fault detection Lodestar CL2B measures current and voltage values of three phasessynchronously. PtG faults registration by Io and Uo at the network frequency. Permanentand transient faults are identified separately.
Possible to implementOperation on Double-side supply linesDetection of line switching off (by voltage)Vibration sensor for analysis of theft, trees fall
А3Technical characteristics Lodestar CL2B
Model Lodestar CL2BOperating voltage <70kVFrequency 50Gz – 60GzMin fault sensing PtG 4А, but min 4% of IloadAbsolute current threshold 20 – 1000АBreaker waiting time (∆t) 0,5 – 200sInrush resistance 0-200sIndication LEDsFault type detection: PtP
PtGYesYes
Communication ComBox (optional)Fault phase indication YesCurrent withstand 25kА/500msRadio Bluetooth Low Energy 4.2 (2.4 GHz)Remote (optional) YesMemory 50 eventsReset Time, Magnet, Line restoration, ComAdjustable reset time 1 - 200 hours, step 1hBattery life 15 – 20 yearsTemperature -40C0 to + 85С0
А3Lodestar CL0.5 – brightest in the industry. Detects Phase to Ground
faults from 0.5A. Lodestar CL0.5 accurate detects all types of faults innetworks with any type of neutral grounding.
Lodestar determinates the transient processes emerged in a network and based on their direction detects Phase to Ground faults.
Intellectual algorithm of FI operation allows Lodestar CL0.5 to identify a direction of a fault location.
Lodestar CL0.5
Lodestar CL0.5 provides synchronous currentand voltage measurement in A,B,C phases forcalculation and analysis.
Advanced FI’s technical characteristics makeLodestar CL0.5 one of the best smartsolutions in prompt and efficient faultlocations localizing.
For immediate fault reporting LodestarCL0.5 transmits data to communication unitvia a build-in radio module.
А3Technical characteristics Lodestar CL0.5
Model Lodestar CL0.5Operating voltage <70kVFrequency 50GzMin fault sensing PtG 0.5А, but min 4% of IloadAbsolute current threshold 20 – 1000АBreaker waiting time (∆t) 0,5 – 200sInrush resistance 0-200sIndication LEDsFault type detection: PtP
PtGYesYes
Fault direction detection YesCommunication ComBox (optional)Fault phase indication YesCurrent withstand 25kА/500msRadio 433,92 GzRemote (optional) YesReset Time, Magnet, Line restoration, ComAdjustable reset time 1h to 7 days (1h to 99hours via Remote)Battery life 7 yearsTemperature -40C0 to + 85С0
А3Lodestar CL0.5B
The principle of the device operation is the same as Lodestar CL0.5The main differences between devices are:
Lodestar CL0.5B radio communication is done using Bluetooth Low Energy standard
Embedded memory for 50 last events (timestamp, min max fault current values, faulttype, faulty phase)
Configuration via Remote control (any portable device: smartphone, tablet) and TheKomorsan Web-client software
Connection to communication unit is possible for 6 sets of Lodestar CL0.5B
Adjustable reset time range: 1-200 hours, 1h step
PtG faults registration by Io and Uo at the network frequency
Possible to implement:Operation on Double-side supply linesDetection of line switching off (by voltage)Vibration sensor for analysis of theft, trees fall
А3Model Lodestar CL0.5BOperating voltage <70kVFrequency 50GzMin fault sensing PtG 0.5А, but min 4% of IloadAbsolute current threshold 20 – 1000АBreaker waiting time (∆t) 0,5 – 200sInrush resistance 0-200sIndication LEDsFault type detection: PtP
PtGYesYes
Fault direction detection YesFault phase indication YesCurrent withstand 25kА/500msCommunication ComBox (optional)Radio Bluetooth Low Energy 4.2 (2.4 GHz)Remote (optional) YesMemory 50 eventsReset Time, Magnet, Line restoration, ComAdjustable reset time 1 - 200 hours, step 1hBattery life 7 yearsTemperature -40C0 to + 85С0
Technical characteristics Lodestar CL0.5B
А3Versatile communicationsFault Indicators
Our developments provide various types of communications:
Data transmission from FIs to the system of power distribution network diagnosticsKomorsan
Data transmission from FIs to a SCADA system via data collecting and processing server Komorsan
Direct data transmission from FIs to SCADA system
Direct data transmission from FIs to various telecontrol and information systems
For data transmission security data encryption algorithms are intendedIKZ
А3Lodestar LightBoxLightBox is a pole mountable communication module. LightBox is
designed to transmit data from fault indicators to the distribution network monitoring system KOMORSAN or a SCADA system.
LightBox provides the real-time analysis of the information derived from fault indicators
In case of fault detection LightBox immediately starts communication sessionwith a server for a fault data transmission and turns blinkers’ yellow side
The standard configuration of data transmission is done bymeans of a builtin GSM modem through the cellularnetwork
LightBox is equipped with a built-in radio. LightBoxcan communicate with Lodestar fault indicatorsand a remote control via a bidirectional wirelessconnection. LightBox configuration is done viathe KOMORSAN WEB-client software and aremote control
LightBox is powered by built-in battery pack and does not require any external power
Communication protocol: proprietary
А3Technical characteristics Lodestar LightBox
Model LightBox
Installation Pole
Communication Radio channel, GPRS
Radio frequency 433,92 MHz
Connection to FI 1 set (3 products)
SCADA integration Via Komorsan
Communication protocol Proprietary
Configuration Komorsan, Remote
Reset Komorsan, Magnet, disconnection
Self diagnostic Yes
Indication Flag
Power supply Battery
Battery life 7 years
Memory 50 events
Temperature -40C0 to +85C0
А3Lodestar LightBox BLightBox B is designed to derive data from Lodestar CL25B, Lodestars
CL2B and Lodestar CL0.5B and to transmit data to the KOMORSAN systemor a SCADA system
Equipped with radio module for communication with Lodestar units using BluetoothLow Energy standart. The standard configuration of data transmission is done by meansof a built-in GSM modem through the cellular network
Configuration of LightBox B can be done via the Komorsan system or remote control (smartphone, tablet )
Powered by built-in battery pack and does not require any external power. Battery lifetime - 20 years.
LightBox B can simultaneously communicate up to 6 Lodestar CL25B/Lodestar CL2B/Lodestar CL0.5B sets
For direct integration to SCADA systems LightBox B supports IEC 60870-5-104 communication protocol
Saves in memory 50 last events: fault time, min and max fault current and voltages values, fault type
LightBox B is equipped with blinkers array for indication
А3Technical characteristics Lodestar LightBox B
Model LightBox BLEInstallation PoleCommunication Radio channel, GPRSRadio frequency 2.4 GHzConnection to FI 6 set (18 products)SCADA integration Via Komorsan, direct via IEC 60870-5-104Communication protocol BLE standard, IEC 60870-5-104Configuration Komorsan, RemoteReset Komorsan, Magnet, disconnection, RemoteSelf diagnostic YesIndication FlagPower supply BatteryBattery life 20 yearsMemory 50 eventsTemperature -40C0 to +85C0
А3Lodestar SmartBoxSmartBox is designed to transmit data from fault indicators directly to
SCADA system. Provides the real-time analysis of the informationderived from all fault indicators.
Standard industrial communications protocols – information is easily integrated intothe existing network infrastructure of the power facility
The standard use case data transmission is done through the cellular operator'snetwork, however if necessary Ethernet interface can be used
Equipped with an external GSM antenna with high sensitivityto provide a stable connection with the cellular operator
Data communication can be done withIEC 60870-5-104 and MODBUS protocols
To improve the cybersecurity level SmartBoxsupports a wide range of encrypted networkprotocols such as Ipsec, OpenVPN and others
SmartBox is powered by a 220 VAC source, forexample, an AUX transformer. SmartBox isequipped with an integrated rechagablebattery capable of supplying the unit with atleast 10 hours of smooth service.
А3Technical characteristics Lodestar SmartBox
Model SmartBox
Installation Pole
Communication Radio channel, GPRS/3G, Ethernet
Radio frequency 433.92MHz
Connection to FI 9 set (27 products)
SCADA integration direct via IEC 60870-5-104
Communication protocol ModBus, IEC 60870-5-104
Configuration WEB-interface configuration software
Self diagnostic Yes
Indication No
Power supply External
Battery life No less than 10 hours
Memory 50 events
Temperature -40C0 to +85C0
А3RelayBox is a pole or wall mountable communication module.
RelayBox is equipped with radio channel, digital inputs and relay outputs
Does not require configuration or additional settings
Provides the real-time analysis of the information derived from all fault indicators
In case of fault detection RelayBox sets a correspondingsignal on the outputs. Relaybox signals received fromthe relay outputs can be used by the customer fortheir needs, for example, they can be redirectedto the data processing centers using discrete
signals and integrated or used in varioustelecontrol and information systems
RelayBox is powered by external powersupply. In case of power failure, the contactsare closed and the power status signal is sentto the relay output
Saves in memory last 50 events.
Lodestar RelayBox
А3Technical characteristics Lodestar RelayBox
Model RelayBox
Installation Pole (Wall optional)
Communication Radio channel, Relay outputs
Radio frequency 433.92MHz
Connection Internal terminals
Telecontrol systems integration Yes
Indication No
Power supply External (12V – 24V DC, 100mA max)
Memory 50 events
Temperature -40C0 to +85C0
А3Distribution network monitoring systemm
A3 provides an intelligent approach for overhead and undergroundnetworks monitoring as a user-friendly, WEB-based plug and play solution
An integrated system of power distributionnetwork diagnostics - "KOMORSAN" isdesigned for immediate short circuitidentification and fault data transmission todispatching point and targeted customers.
When fault occurs the System soundsaudible alarm, displays the place of a faulton a map and notifies maintenance crew viaSMS and E-mail reducing time for faultlocalization.
Configuration and control of diagnosticdevices are done remotely.
А3KOMORSAN Systemarchitecture
The Komorsan system consists of:
Data collecting and processing server; DataBase; Komorsan Web-client software;
А3
The measuring part of the System includes short-circuit indicators for OHL andunderground networks, Icing sensors, feeder monitoring devices that providemeasurements of electrical network main parameters and processesoccurring in it.
Communication units perform communicationbetween the measuring and control parts of theSystem.
Data processing server collects data fromSensors via industrial protocols ModBusand IEC 60870–5-104.
Data exchange with external systems/SCADA integration is performed viaIEC 60870–5-104.
KOMORSANSystem
А3KOMORSAN System overview
The KOMORSAN Web-client software provides:
Secure data access. Log-in the System is available using account.Complete control of user roles and permission levels. The System administrator can createand manage users roles, permission levels and available features.No limits for quantity of simultaneously logged users.Event mapping on any type of network topology.Mimic diagrams displays on terrain map with devicesinstalled.Analysis and Diagnostics. Wide set of analyticaltools. Data can be combined and processedregarding to a device, event or an object. Youchoose which parameters to view and the orderin which you view them. All data are presentedin graphical or tabular formats.Data export. All necessary information can beexported in PDF, HTML or CSV formats.Waveform recording. Recorded waveforms canbe viewed and exported in comtrade format.System life cycle support. Release updates +technical support
А3
А3KOMORSAN technical characteristics
System requirementsSupported platforms LinuxDatabase PostgreSQLProcessor Xeon 4C E3-1241v3 (or any similar)x1Processor type 3.5GHz/1600MHz/8MbRAM 8Gb DDR3HDD SAS/SATA, 7.2K 6Gbps NL, 2x 500Gb Dual Ethernet Yes
ManagementUser access management YesFault notification Alarm, SMS, E-mailContinuous storage of all information RetrospectiveFI threshold and settings Remotely adjustableData export Yes
CommunicationsData exchange with external systems IEC 60870-5-104 protocol
DevicesOHL FI Lodestar CL25B/CL2B/CL0.5B, Lodestar CL2/CL0.5, IKZ-V2Cable FI IKZ-KFeeder monitor A-SignalIcing sensors DOComBox LightBox, LightBox BLE, SmartBox