Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
1 2 3 4 5 6 7 9 10 11 12 13 14 15 16 17 18 19
B
C
D
E
F
G
H
J
2019.21.8 8
CORRIDOR
300
STAIR A
ST-A3
KING
SUITE
301
KING
SUITE
303
KING
304
KING
305
KING
306
KING
307
KING
308
KING
309
KING
310
KING
SUITE
312
KING
318
319
KING
320
321
KING
322
323
KING
324
KING
SUITE
326
KING
SUITE
328
329
330
KING
SUITE
331
332
KING
SUITE
333
ACCESSIBLE KING
334
QUEEN QUEEN
335
STAIR B
ST-B3
DOUBLE
QUEEN
337
KING
311
ACCESSIBLE KING
SUITE
313
KING
SUITE
315
HOUSE KEEPING
336
316
KING
SUITE
314
ELEVATOR
E-3
ICE
317
KING
WIDE
302
QUEEN QUEEN
QUEEN QUEEN
QUEEN QUEEN
QUEEN QUEEN
QUEEN
QUEEN
QUEEN QUEEN
ELEV
LOBBY
315
CORRIDOR
300
327
QUEEN SUITE
KING
GFCI
P3:4
P3:5
P3
P3-B
1/8" = 1'-0"E331
1 LEVEL 3 POWER PLAN
GENERAL NOTES:
1. SEE SHEET E500 FOR GUEST ROOM ENLARGED PLANS.
2. CIRCUIT NUMBERS SHOWN FOR COUNT ONLY. CONTRACTOR TO DETERMINE
ACTUAL CIRCUIT NUMBERS IN THE FIELD. WIRE RECEPTACLE CIRCUITS TO PANEL
P3.
320
0 P
LE
AS
AN
T R
UN
, S
UIT
E A
SP
RIN
GF
IE
LD
, ILL
IN
OIS
, 627
11
Phon
e: (2
17) 7
93-2
299
Fa
x: (217
) 7
93
-331
1
ww
w.trcw
w.com
ROBERT A. BOELLNER
STATE OF TEXAS
PR
OFESSION A L ENG
RIN
EEREGIS
D
T E RE
EXPIRES: 06-30-2016
SIGNED: 12-14-2015
1 2 3 4 5 6 7 9 10 11 12 13 14 15 16 17 18 19
B
C
D
E
F
G
H
J
2019.21.8 8
LINEN CHUTE
VENT
FIREPLACE
VENT
ERV-2
APPROX WEIGHT:
2500 lbs
30x14 SA DN
32x14 EA DN
TEF-1
300 CFM
TEF-1
150 CFM
TEF-1
300 CFM
TEF-1
300 CFM
TEF-1
450 CFM
TEF-1
300 CFM
TEF-1
150 CFM
TEF-1
200 CFM
TEF-1
200 CFM
TEF-1
300 CFM
TEF-1
100 CFM
TEF-1
100 CFM
TEF-1
200 CFM
TEF-1
100 CFM
TEF-1
100 CFM
TEF-1
200 CFM
TEF-1
100 CFM
TEF-1
200 CFM
TEF-1
100 CFM
TEF-1
200 CFM
GFCI
WP
P3:6
P3:7-9
P3:6-8
P3:11-13
P3:10-12
P3:15-17
DP2:1-3
1/8" = 1'-0"E341
1 ROOF POWER PLAN
PLAN NOTE:
1EQUIPMENT FURNISHED WITH INTEGRAL DISCONNECT SWITCH.
PROVIDE 45A/3P CIRCUIT BREAKER IN PANEL INDICATED.2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
GENERAL NOTES:
1. SEE SHEET E500 FOR GUEST ROOM ENLARGED PLANS.
2. CIRCUIT NUMBERS SHOWN FOR COUNT ONLY. CONTRACTOR TO DETERMINE
ACTUAL CIRCUIT NUMBERS IN THE FIELD. WIRE RECEPTACLE CIRCUITS TO PANEL
INDICATED.
320
0 P
LE
AS
AN
T R
UN
, S
UIT
E A
SP
RIN
GF
IE
LD
, ILL
IN
OIS
, 627
11
Phon
e: (2
17) 7
93-2
299
Fa
x: (217
) 7
93
-331
1
ww
w.trcw
w.com
ROBERT A. BOELLNER
STATE OF TEXAS
PR
OFESSION A L E NG
RIN
EEREGIS
D
T E RE
EXPIRES: 06-30-2016
SIGNED: 12-14-2015
1/4
" / 1
'-0
"
1/4
" / 1
'-0
"
1/4" / 1'-0"
1/4
" / 1'-0
"
1/4" / 1'-0"
1/4
" / 1
'-0
"1
/4
" / 1
'-0
"
1/4" / 1'-0"
1/4" / 1'-0"
1/4" / 1'-0"
1/4" / 1'-0"
1/8
" / 1
'-0
"
C
D
F
G
J
K
0.7
G.1
G.9
0.30.5 0.20.6 0.4 1 0.1
1/4" / 1
'-0
"1/4
" / 1'-0
"
1/4" / 1'-0"
1/4
" / 1
'-0
"
1/4
" / 1
'-0
"
1/4" / 1
'-0"
1/4" / 1'-0"
1/4" / 1'-0"
1/4
" / 1
'-0
"1
/4
" / 1
'-0
"1
/8
" / 1'-0
"1
/4
" / 1
'-0
"1/4
" / 1'-0
"
K-MAU-1
KEF-1
ACCU-1 ACCU-2
DEF-1
SCU-1
GFCI
WP
DP2:2-4
DP2:5-7-9
DP2:6-8-10
DP2:11-13-15
DP2:12-14
DP2:16-18
DP2:17-19
DP2:20-22-24
P1A:61
ERV-1
GFCI
WP
P1A:61
1/8" = 1'-0"E341A
1 ROOF PLAN - CONFERENCE
MA
TC
H L
IN
E
SE
E E
34
1
MA
TC
H L
IN
E
SE
E E
34
1
PLAN NOTE:
1EQUIPMENT FURNISHED WITH INTEGRAL DISCONNECT SWITCH.
PROVIDE 60A/3P NEMA 3R NON-FUSED DISCONNECT SWITCH. PROVIDE 40A/3P CIRCUIT
BREAKER IN PANEL INDICATED.
PROVIDE 30A/3P NEMA 3R NON-FUSED DISCONNECT SWITCH. PROVIDE 20A/3P CIRCUIT
BREAKER IN PANEL INDICATED.
PROVIDE 100A/3P NEMA 3R NON-FUSED DISCONNECT SWITCH. PROVIDE 70A/3P CIRCUIT
BREAKER IN PANEL INDICATED.
PROVIDE 60A/3P NEMA 3R NON-FUSED DISCONNECT SWITCH. PROVIDE 35A/3P CIRCUIT
BREAKER IN PANEL INDICATED.
PROVIDE 60A/3P NEMA 3R NON-FUSED DISCONNECT SWITCH. PROVIDE 50A/3P CIRCUIT
BREAKER IN PANEL INDICATED.
PROVIDE 35A/3P CIRCUIT BREAKER IN PANEL INDICATED.
2
3
4
5
6
1
1
2
3
4
5
6
7
1
7
GENERAL NOTES:
1. SEE SHEET E500 FOR GUEST ROOM ENLARGED PLANS.
2. CIRCUIT NUMBERS SHOWN FOR COUNT ONLY. CONTRACTOR TO DETERMINE
ACTUAL CIRCUIT NUMBERS IN THE FIELD. WIRE RECEPTACLE CIRCUITS TO PANEL
INDICATED.
320
0 P
LE
AS
AN
T R
UN
, S
UIT
E A
SP
RIN
GF
IE
LD
, ILL
IN
OIS
, 627
11
Phon
e: (2
17) 7
93-2
299
Fa
x: (217
) 7
93
-331
1
ww
w.trcw
w.com
ROBERT A. BOELLNER
STATE OF TEXAS
PR
OFESSION A L E NG
R
INE
EREGIS
D
T E RE
EXPIRES: 06-30-2016
SIGNED: 12-14-2015
HB
1 2 3 4 5 6 7 9 10 11 12 13 14 15 16 17 18 19
A
B
C
D
E
F
G
H
J
K
2019.21.8 8
HB
HB
HB
HB
SD
MH
HH
SD SD SD SDSD SD
ER
SD SD SDSDSD
SD
ER
M
V
FAAP
V
V
V
FACP
SD
V
H
M
M
VV
H
H
SD
SD
H
WP
V
WOMENS
HALL
117
VESTIBULE
LIVING
ROOM
RECEPTION
RETAIL
SERVERY
PANTRY
WORK
ROOM
OFFICE
BREAK ROOM
MAINT
MEETING ROOM
STAIR
FITNESS
QUEEN QUEEN QUEEN QUEEN
CORRIDORB
QUEEN QUEEN
POOL DECK
ACCESSIBLE
QUEEN
QUEEN
KING
SUITE
QUEEN QUEEN
KING
KING
SUITE
KING
KING
SUITE
ACCESSIBLE
KING
QUEEN QUEEN
STAIR B
QUEEN QUEEN
MECH
VERANDA
POOL EQUIP,
MECH
MEN
WOMEN
MENS
TELECOM
ELEC
CARTS
MECH
ELEVATOR
LOBBY
ICE
STORAGE A
ELEV EQUIP
ELEVATOR
STORAGE
B
BREAKFAST
LAUNDRY
CHUTE
GUEST
LAUNDRY
PORTE
COCHERE
CORRIDOR A
OFFICE
PO
OL A
CC
ES
S
CO
OR
ID
OR
STORAGE C
DEN/
BUSINESS
CENTER
QUEEN SUITE
100
101A
113A
114
112
109A
109B
109C
124B
103
ST-A1
140
119 121
138
123
143A
126
128
129
130
131
132
133
134
135
ST-B1
137
108
124A
141
142
105 107
118
110B
113C
110A
115
120
106
117B
139
117A
243
101B
104
109D
113B
104A
122
102
104B
116
127
FSTS
FSTS
A
V
V
H
V
H
V
H
V
H
H
H H H
V
V
V
H
WP
H
WP
H
WP
V
MM
HD
AR
HDSD
ER
1/8" = 1'-0"E411
1 LEVEL 1 SYSTEMS PLAN
MA
TC
H LIN
E
SE
E S
HE
ET
E41
1A
MA
TC
H LIN
E
SE
E S
HE
ET
E411A
PLAN NOTE:
1PROGRAM FIRE ALARM SYSTEM TO SHUNT TRIP THE ELEVATOR BREAKER WHEN THE
HEAT DETECTOR IS ACTIVATED.
1
320
0 P
LE
AS
AN
T R
UN
, S
UIT
E A
SP
RIN
GF
IE
LD
, ILL
IN
OIS
, 627
11
Phon
e: (2
17) 7
93-2
299
Fa
x: (217
) 7
93
-331
1
ww
w.trcw
w.com
ROBERT A. BOELLNER
STATE OF TEXAS
PR
OFESSION A L E NG
R
INE
EREGIS
D
T E RE
EXPIRES: 06-30-2016
SIGNED: 12-14-2015
1 2 3
C
D
F
G
J
K
MEETING ROOM103
STAIR AST-A1
1.8
STORAGE A106
FEC
104LAUNDRY
CHUTE104A CORRIDOR A
102
OFFICE104B
0.7
G.1
G.9
0.30.5 0.20.6 0.4 0.1
V
V
H
M
M
M
M
H
M
M
HH
H
HH
VESTIBULE
LOBBY
LOBBY
CONFERENCE A
CONFERENCEB
CONFERENCEC
WOMENS
MENS
KITCHEN
DISHWASHING
141
140
139146
142
143
144A
144
145
CORRIDOR
138
147
M
V
HH
H
V
VM
H
AR
MA
TC
H L
IN
E
SE
E S
HE
ET
E4
11
MA
TC
H L
IN
E
SE
E S
HE
ET
E4
11
1/8" = 1'-0"
E411A
1 LEVEL 1 SYSTEM - CONFERENCE
320
0 P
LE
AS
AN
T R
UN
, S
UIT
E A
SP
RIN
GF
IE
LD
, ILL
IN
OIS
, 627
11
Phon
e: (2
17) 7
93-2
299
Fa
x: (217
) 7
93
-331
1
ww
w.trcw
w.com
ROBERT A. BOELLNER
STATE OF TEXAS
PR
OFESSION A L E NG
R
INE
EREGIS
D
T E RE
EXPIRES: 06-30-2016
SIGNED: 12-14-2015
112' - 1 3/8"
112' - 4 3/8"
112' - 1 3/8"
112' - 1 3/8"
112' - 7"
1 2 3 4 5 6 7 9 10 11 12 13 14 15 16 17 18 19
BB
CC
DD
EE
FF
GG
HH
JJ
2019.21.8
1/2" / 1'-0"
8
1
/4
"
/ 1
'-
0
"
1
/4
"
/ 1
'-
0
"
1
/
8
"
/
1
'-
0
"
1
/
8
"
/
1
'-
0
"
112' - 2 9/16"
1/4" / 1'-0"
1/4" / 1'-0"
M
SD
MH HH
SD SD SD SDSD
SD
ER
SD SD SDSDSD
ELEV
LOBBY
STAIR A
ST-A2
CORRIDOR
200
KING
SUITE
201
KING
WIDE
202
KING
SUITE
203
KING
204
KING
205
KING
206
KING
207
KING
208
KING
209
KING
SUITE
212
KING
SUITE
214
KING
218
219
KING
220
221
KING
222
223
KING
224
KING
SUITE
226
KING
SUITE
228
QUEEN QUEEN
229
QUEEN QUEEN
230
KING
SUITE
231
QUEEN QUEEN
232
KING
SUITE
233
ACCESSIBLE KING
234
QUEEN QUEEN
235
STAIR B
ST-B2
QUEEN QUEEN
237
KING
211
HOUSE KEEPING
236
KING
WIDE
216
KING
210
ICE
217
ELEVATOR
E-2
QUEEN QUEEN
QUEEN QUEEN
QUEEN QUEEN
237
215
CORRIDOR
200
227
QUEEN SUITE
FS TS
H H HH
V
SD
1/8" = 1'-0"E421
1 LEVEL 2 SYSTEMS PLAN
320
0 P
LE
AS
AN
T R
UN
, S
UIT
E A
SP
RIN
GF
IE
LD
, ILL
IN
OIS
, 627
11
Phon
e: (2
17) 7
93-2
299
Fa
x: (217
) 7
93
-331
1
ww
w.trcw
w.com
ROBERT A. BOELLNER
STATE OF TEXAS
PR
OFESSION A L E NG
R
INE
EREGIS
D
T E RE
EXPIRES: 06-30-2016
SIGNED: 12-14-2015
1 2 3 4 5 6 7 9 10 11 12 13 14 15 16 17 18 19
B
C
D
E
F
G
H
J
2019.21.8 8
M
M
SD SD SD SD SDSD SD
ER
SD SD
SD
SDSD
H HH
CORRIDOR
300
STAIR A
ST-A3
KING
SUITE
301
KING
SUITE
303
KING
304
KING
305
KING
306
KING
307
KING
308
KING
309
KING
310
KING
SUITE
312
KING
318
319
KING
320
321
KING
322
323
KING
324
KING
SUITE
326
KING
SUITE
328
329
330
KING
SUITE
331
332
KING
SUITE
333
ACCESSIBLE KING
334
QUEEN QUEEN
335
STAIR B
ST-B3
DOUBLE
QUEEN
337
KING
311
ACCESSIBLE KING
SUITE
313
KING
SUITE
315
HOUSE KEEPING
336
316
KING
SUITE
314
ELEVATOR
E-3
ICE
317
KING
WIDE
302
QUEEN QUEEN
QUEEN QUEEN
QUEEN QUEEN
QUEEN QUEEN
QUEEN
QUEEN
QUEEN QUEEN
ELEV
LOBBY
315
CORRIDOR
300
327
QUEEN SUITE
KING
FS TS
H H HH
V
SD
HD
1/8" = 1'-0"E431
1 LEVEL 3 SYSTEMS PLAN
320
0 P
LE
AS
AN
T R
UN
, S
UIT
E A
SP
RIN
GF
IE
LD
, ILL
IN
OIS
, 627
11
Phon
e: (2
17) 7
93-2
299
Fa
x: (217
) 7
93
-331
1
ww
w.trcw
w.com
ROBERT A. BOELLNER
STATE OF TEXAS
PR
OFESSION A L E NG
R
INE
EREGIS
D
T E RE
EXPIRES: 06-30-2016
SIGNED: 12-14-2015
42"
SD
34"
34"
GFCI
R2
R2
26"
26"
R1
R3
R4
34"
34"
42"
26"
26"
SD
GFCI
R2
R2
R1
R3
R4
GFCI
R2
R2
R1
R1
R3
R4
V
34"
34"
42"
26"
26"
V
V
SD
42"
R3
R3
R3
R3
R3
R3
R1
R1
R1
R2
R2
R2
R2
R2
R2
GFCI
R2
R2 R4
R4
R4
R4
42"
42"
42"
42"
26"
26"
26"
26"
26"
26"
26"
26"
34"
34"
34"
34"
34"
34"
34"
34"
V
V
V
V
SD
SD
SD
SD
GFCI
GFCI
GFCI
56"
42"
42"
42"
42"
42"
42"
42"
56"
PTAC PTAC
VTAC
VTAC
VTAC
PTAC
PTAC
a
CKT-1,3
F20
CKT-2
CKT-4
a
a,b
a
b
a
b
b
M
M
F20
CKT-1,3
b
b
b
a
a
a
CKT-4
CKT-2
F20
CKT-1,3
CKT-4
CKT-2
a,b
a
a
a
a
a
a,b
b
b
F20
CKT-1,3
CKT-1,3
F20
CKT-1,3
F20
M
CKT-1,3F20
CKT-2
a,b
CKT-2
a,b
CKT-2
a,b
CKT-2
CKT-4
a
a
b
a,b
b
b
b
a
b
42"
b
a
a
a b
a
b
CKT-4
CKT-4
a
b
a
a
b
a
b
CKT-4
b
b
b
a
a
a
a
b
209
KING
QUEEN QUEEN
KING SUITE
ACCESSIBLE KING
ACCESSIBLE QUEEN QUEEN
ACCESSIBLE KING SUITE
KING SUITE
1/4" = 1'-0"E500
2 QUEEN QUEEN
1/4" = 1'-0"E500
1 KING
1/4" = 1'-0"E500
3 KING SUITE
1/4" = 1'-0"E500
3 ACCESSIBLE KING GUESTROOM
1/4" = 1'-0"E500
5 ACCESSIBLE QUEEN QUEEN
1/4" = 1'-0"E500
6 ACCESSIBLE KING SUITE
1/4" = 1'-0"E500
7 KING SUITE ALTERNATE
GENERAL NOTE:
1
1. FOR ELECTRICAL SYMBOLS, ABBREVIATIONS AND GENERAL NOTES, SEE SHEET E001.
2. SEE LIGHTING FIXTURE SCHEDULE ON SHEET E600.
3. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT PLACEMENT OF
LIGHTING FIXTURES.
4. ALL RECEPTACLE SHALL BE MOUNTED AT +18" AFF UNLESS NOTED OTHERWISE.
5. FIRE ALARM VENDOR TO PROVIDE COMPLETE SHOP DRAWINGS TO THE AUTHORITY
HAVING JURISDICTION FOR REVIEW AND APPROVAL. FIRE ALARM VENDOR TO INCLUDE
ANY ADDITIONAL DEVICES TO PROVIDE A FULLY FUNCTIONAL SYSTEM.
6. COORDINATE ALL DEVICE LOCATIONS WITH ARCHITECT PRIOR TO ROUGH IN.
7. PROVIDE SMOKE DETECTOR WITH SOUNDER BASE IN EACH ROOM ON THIS SHEET.
SMOKE DETECTOR SHALL ACTIVATE SOUNDER BASE AND STROBES WITHIN THE ROOM
ONLY AND INDICATE A SUPERVISORY SIGNAL ON THE FACP. SOUNDER BASE AND
STROBES WILL ACTIVATE.
8. ALL RECEPTACLES IN GUEST ROOM UNITS SHALL BE TAMPER RESISTANT.
9. ALL SLEEPING ROOMS WILL HAVE A VISUAL DEVICE. ONLY ACCESSIBLE ROOMS WILL
HAVE A VISUAL DEVICE IN THE BATHROOM.
10. GUESTROOM BATHROOMS SHALL HAVE DEDICATED CIRCUIT SERVING GFCI
RECEPTACLE.
11. ALL GUESTROOMS SHALL HAVE A MASTER ROCKER SWITCH AT ENTRY LABELED
"MASTER SWITCH" TO CONTROL HARD WIRED FIXTURES AND SWITCHED OUTLETS.
12. CIRCUIT NUMBERS SHOWN FOR COUNT ONLY. CONTRACTOR TO DETERMINE ACTUAL
CIRCUIT NUMBERS IN THE FIELD. WIRE GUEST ROOM CIRCUITS TO THE FOLLOWING
PANELS:
FIRST FLOOR P1A
SECOND FLOOR : P2 AND P2B
THIRD FLOOR: P3 AND P3B.
PLAN NOTE:
1DESK OPTION 1 (2 - OUTLETS / 1 - USB), DESK OPTION 2 (2 - OUTLETS / 1 - DATA)
2KING HEADBOARD - OPTION 1 (2 - OUTLETS / 1 - USB), QUEEN QUEEN HEADBOARD -
OPTION 1 (2 - OUTLETS / 1 - USB)
2
2
1
1
1
1
1
1
320
0 P
LE
AS
AN
T R
UN
, S
UIT
E A
SP
RIN
GF
IE
LD
, ILL
IN
OIS
, 627
11
Phon
e: (2
17) 7
93-2
299
Fa
x: (217
) 7
93
-331
1
ww
w.trcw
w.com
ROBERT A. BOELLNER
STATE OF TEXAS
PR
OFESSION A L ENG
R
INE
EREGIS
D
T E RE
EXPIRES: 06-30-2016
SIGNED: 12-14-2015
REF.
1
J
K
0.2 0.1
144KITCHEN
144ADISHWASHING
GFCI
GFCI
GFCI
GFCI
GFCIGFCI
DISH WASHING
ICE MAKER-15A/120V
COFFEE MAKER-12A/120V
MICROWAVE-1500VA/120V
TOASTER-12A/120V
J
20KW/208V/3PH
COOLER-15A/120V
COOLER-15A/120V
REF-9A/120V
WAFFEL MAKER
15A/120V
12A/120V
P1A:20
P1A:21
P1A:22
P1A:23
P1A:24
SLICER
10A/120V
P1A:25
P1A:26
P1A:27 P1A:28
P1A:29
P1A:30,32,34
CAN OPENER-180VA/120V
1/4" = 1'-0"
E501
1 ENLARGED ELECTRICAL KITHCEN AREA PLAN
1
PLAN NOTE:
1PROVIDE SHUNT TRIP ON THE CIRCUIT BREAKER AND WIRE THE SHUNT TRIP CIRCUIT
THROUGH THE HOOD SUPRESSION SYSTEM.
GENERAL NOTES:
1. CIRCUIT NUMBERS SHOWN FOR COUNT ONLY. CONTRACTOR TO DETERMINE
ACTUAL CIRCUIT NUMBERS IN THE FIELD. WIRE RECEPTACLE CIRCUITS TO PANEL
INDICATED.
32
00 P
LE
AS
AN
T R
UN
, S
UIT
E A
SP
RIN
GF
IE
LD
, IL
LIN
OIS
, 62
71
1
Pho
ne: (21
7) 793
-229
9
Fax: (21
7) 79
3-33
11
ww
w.trcw
w.com
ROBERT A. BOELLNER
STATE OF TEXAS
PR
OFESSION A L ENG
R
INE
EREGIS
D
T E RE
EXPIRES: 06-30-2016
SIGNED: 12-14-2015
TAG
FIXTURE DESCRIPTION
MOUNTING
F1 SUSPENDED 2x4 DIRECT/INDIRECT PENDANT LIGHT FIXTURE WITH THREE 54W T5-HO LAMPS.
F2 WALL INTERIOR SCONCE WITH 42W CFL LAMP AND BATTERY PACK.
F3 WALL INTERIOR SCONCE WITH 10W LED LAMP
F4 DECORATIVE SURFACE FIXTURE WITH TWO 13W CFL LAMPS.
F5
F6
F7
F8
F9
F10
F11
F12
F13
F14
F15
F16
F17
F18
F19
X2
1x4 SURFACE LIGHT FIXTURE WITH TWO 32W T8 LAMPS.
RECESSED RECESSED FIXTURE WITH 1000 LUMEN LED.
RECESSED RECESSED FIXTURE WITH 1300 LUMEN LED.
SUSPENDED PENDANT FIXTURE WITH 42W CFL LAMP.
RECESSED RECESSED FIXTURE WITH 1000 LUMEN LED.
EXTERIOR SCONCE WITH 18W CFL LAMP AND BATTERY PACK.WALL
RECESSED FIXTURE WITH 13W CFL LAMP.
DECORATIVE PENDANT FIXTURE WITH FOUR 9W LED LAMPS.SUSPENDED
SQUARE RECESSED FIXTURE WITH 1000 LUMEN LED LAMP.RECESSED
1x4 SURFACE LIGHT FIXTURE WITH TWO 32W T8 LAMPS PER FOUR FOOT SECTION.CEILING
1x4 45W LED SURFACE LIGHT FIXTURE.CEILING
RECESSED WET RATED SHOWER FIXTURE WITH 1000 LUMEN LED.
RECTANGULAR DOWN LIGHT WITH THREE HEADS HAVING ONE 18W CFL LAMP EACH.
RECESSED FIXTURE WITH 13W CFL LAMP.
RECESSED
RECESSED
RECESSED
DECORATIVE SCONCE WITH TWO 18W CFL LAMPS.WALL
DUAL HEAD LED EGRESS FIXTURE WITH HIGH OUTPUT LIGHT HEADS.WALL
LIGHT FIXTURE SCHEDULE
TAG
FIXTURE DESCRIPTION
MOUNTING
R1 CEILING DECORATIVE ENTRY FIXTURE WITH THREE 13W CFL LAMPS.
R2 WALL VANITY FIXTURE WITH 13W CFL LAMP.
R3 RECESSED RECESSED WET RATED SHOWER FIXTURE WITH 1000 LUMEN LED.
R4 CEILING 12V LED SURFACE PUCK FIXTURE WITH REQUIRED ACCESSORIES.
GUESTROOM LIGHT FIXTURE SCHEDULE
REMARKS
PROVIDE BATTERY CAPABLE OF ILLUMINATING ONE LAMP
FOR 90 MINUTES WHERE INDICATED ON FLOOR PLANS
CEILING
CEILING
RECESSED
CEILING/WALL LED EXIT FIXTURE - SINGLE OR DOUBLE FACE WITH AROWS AS INDICATED ON PLAN.X1
F20 85W LED COVE LIGHT FIXTURE.WALL
F21 17W LED WALL PACK FIXTURE WITH INTEGRAL BATTERY PACKWALL
320
0 P
LE
AS
AN
T R
UN
, S
UIT
E A
SP
RIN
GF
IE
LD
, ILL
IN
OIS
, 627
11
Phon
e: (2
17) 7
93-2
299
Fa
x: (217
) 7
93
-331
1
ww
w.trcw
w.com
ROBERT A. BOELLNER
STATE OF TEXAS
PR
OFESSION A L E NG
R
INE
EREGIS
D
T E RE
EXPIRES: 06-30-2016
SIGNED: 12-14-2015
UTILITY TRANSFORMER. EC TO
PROVIDE TRANSFORMER BASE
AND GROUNDING PER UTILITY
COMPANY.
MSB
UTILITY POWER POLE.
LOCATION TO BE
DETERMINED.
P3
P2
P1A
P1B
EQUIPMENT
GROUND
CONDUIT SIZE AND QUANTITY
2-1/2"
1/0
F2000 500
F900
F1600
F1200
F1000
350
500
350
500
250
2/0
2/0
3/0
4/0
F450 4/0
F800
F500
F600
F700
350
350
500
250
F250
F300
F350
F400
500
350
250
2
1
1/0
2
4
3
4
(3) 3"(3) 2-1/2"
(6) 3"
(4) 2-1/2"
(3) 2-1/2"
(5) 3"
(3) 3"
(6) 3-1/2"
(4) 3"
(5) 3"
(3) 3"
(3) 3"
(2) 2"
(2) 2-1/2"
(2) 3"
(2) 2"
2"
2"
3"
2-1/2"
2"
(2) 2-1/2"
(2) 3"
(2) 3"
(2) 2-1/2"
3"
2-1/2"
3"
1-1/4"
1-1/4"
1-1/4"
1-1/2"
1-1/4"
FEEDER SCHEDULE
F60 106
F150
F175
F225
F200 3/0
4/0
1/0
2/0
F125
F110
F90 & F100
F70 & F80
3
2
1
4
6
6
6
4
8
6
6
8
NEUTRAL
PHASE AND
CONDUCTOR PER CONDUIT
F30
F20
F40 & F50
10
8
12
FEEDER
10
10
12
OR
1"3/4" 3/4"
1-1/4"
2"
2"
1-1/2"
1-1/2"
1"
1"
3/4"
1"
1-1/4"
1"
1-1/2"
2-1/2"
2"
2"
1-1/2"
1-1/4"
1-1/4"
1-1/4"
2P, 1N, 1G1P, 1N, 1G
3/4"
3/4"
2P, 1G
3/4"
3/4"
3/4"
3P, 1G
OR
3/4"
3P, 1N, 1G
3/4"
3/4"
3/4"
(3) 3-1/2"
(6) 4"
(4) 3-1/2"
(3) 3-1/2"
(5) 4"
(3) 4"
(2) 3"
(2) 3"
(2) 3-1/2"
(2) 4"
3"
4"
3-1/2"
1"
2"
2"
2-1/2"
2-1/2"
2-1/2"
1-1/2"
1-1/2"
1-1/4"
3P, 3N, 1G
1"
3/4"
3/4"
2-1/2"500 3
3" 3" 4"
-
-
-
-
-
-
-
-
-
-
DP2
F400
F400
F400
F400
F3000
DESIGNATION
TO BUILDING
GROUND SYSTEM.
3/0 COPPER GROUND IN
3/4" CONDUIT. SEE
GROUNDING RISER DETAIL
THIS SHEET.
F1200
#3/0 BARE COPPER IN 1" SCHEDULE 40 PVC
CONDUIT TO DRIVEN GROUND FIELD.
GROUND BUS LOCATED IN MAIN
SWITCHBOARD "MSB".
#3/0 AWG IN 3/4" CONDUIT FROM
WATER SERVICE.
#4 AWG IN3/4" PVC CONDUIT FROM REBAR
LOCATED IN THE BOTTOM OF FOUNDATION
FOOTINGS.
PROVIDE #3/0 BARE SOLID COPPER
CONDUCTOR BETWEEN GROUND RODS AND
ATTACH WITH EXOTHERMIC WELDED
CONNECTIONS 6" BELOW TOP OF RODS.
INSTALL GROUND FIELD IN THE NEAREST AVAILABLE
EXTERIOR UNPAVED AREA PER THE REQUIREMENTS OF
N.E.C. ARTICLE 250. RECORD INSTALLED LOCATION ON
CONSTRUCTION RECORD DOCUMENTS.
#3/0 BARE COPPER CONDUCTOR FROM MAIN
GROUND BUS. ATTACH WITH BOLTED CONNECTION
IN TEST WELL.
TYPICAL - 3/4" X 10'-0" COPPERWELD GROUND ROD DRIVEN IN
10'-0" EQUILATERAL TRIANGLE. GROUND FIELD SHALL BE A
MINIMUM OF 2'-0" AWAY FROM THE BUILDING.
EC TO PROVIDE CONDUITS PER UTILITY COMPANY.
F400
HOUSEKEEPING PAD
INTEGRAL
POWER METER
SURGE SUPPRESSION
DEVICE
TO PIPING SYSTEMS REQUIRED BY CODE TO BE
BONDED SUCH AS GAS, DUCT WORK, STORM, ETC.
IN ACCORDANCE WITH NATIONAL ELECTRIC CODE
250.104(B).
F3000 500 250(9) 3" (9) 3-1/2" (9) 4"
-
UTILITY REVENUE
METER
400A
/3P
400A
/3P
400A
/3P
400A
/3P
1200A
/3P
400A
/3P
100A
/3P
3000A
/3P
FURNISH MSB WITH AIC RATING OF 65K
300A
/3P
300A
/3P
300A
/3P
1200A
/3P
WA
TE
R H
EA
TE
R-1
WA
TE
R H
EA
TE
R-2
WA
TE
R H
EA
TE
R-3
DP1
F300 F300 F300
LP1
F100
100A
/3P
F100
POOL
TO BE DESIGNED BUILD
UNDER OTHER PERMIT.
ELEVATOR
100A
/3P
ELEVATOR CONTROLLER
PROVIDE CIRCUIT BRAEKER WITH
24V SHUNT TRIP AND CONNECT FOR
FIRE ALARM SYSTEM CONTROL.
P3B
PROVIDE CIRCUIT BREAKER WITH
24V SHUNT TRIP AND WIRE TO FIRE
ALARM SYSTEM THROUGH
ADDRESSABLE RELAY.
F70
P2B
NTSE700
1 NORMAL POWER RISER DIAGRAM
NTSE700
2 GROUNDING RISER DIAGRAM
NTSE700
3 GROUND FIELD DIAGRAM
320
0 P
LE
AS
AN
T R
UN
, S
UIT
E A
SP
RIN
GF
IE
LD
, ILL
IN
OIS
, 627
11
Phon
e: (2
17) 7
93-2
299
Fa
x: (217
) 7
93
-331
1
ww
w.trcw
w.com
ROBERT A. BOELLNER
STATE OF TEXAS
PR
OFESSION A L E NG
R
INE
EREGIS
D
T E RE
EXPIRES: 06-30-2016
SIGNED: 12-14-2015