27
HIPPS Solution Danish Offshore Show Esbjerg, March 26 th 2015 Carsten Thøgersen

Official EmersonProcess PPT Presentation Template...27-Jun-01, Slide 18 Increased Diagnostic Coverage Diagnose mechanical failures before they happen AMS ValveLink uploads PST results

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Official EmersonProcess PPT Presentation Template...27-Jun-01, Slide 18 Increased Diagnostic Coverage Diagnose mechanical failures before they happen AMS ValveLink uploads PST results

HIPPS Solution Danish Offshore Show

Esbjerg, March 26th 2015

Carsten Thøgersen

Page 2: Official EmersonProcess PPT Presentation Template...27-Jun-01, Slide 18 Increased Diagnostic Coverage Diagnose mechanical failures before they happen AMS ValveLink uploads PST results

[File Name or Event] Emerson Confidential 27-Jun-01, Slide 2

Agenda

Increased demand for HIPPS, why?

Short about HIPPS and the benefits

The Challenges faced

Challenges on a product level

A Solution addressing all challenges/phases

Questions

Page 3: Official EmersonProcess PPT Presentation Template...27-Jun-01, Slide 18 Increased Diagnostic Coverage Diagnose mechanical failures before they happen AMS ValveLink uploads PST results

[File Name or Event] Emerson Confidential 27-Jun-01, Slide 3

Increased demand for HIPPS, Why?

The increased demand for HIPPS is driven by different factors.

Environmental issues

Regulatory Directives – Reduce Flare

Reduce OPEX (test of relief valves)

Page 4: Official EmersonProcess PPT Presentation Template...27-Jun-01, Slide 18 Increased Diagnostic Coverage Diagnose mechanical failures before they happen AMS ValveLink uploads PST results

[File Name or Event] Emerson Confidential 27-Jun-01, Slide 4

Short about HIPPS and the benefits

Shutting off the source

Protecting Personnel

Automatic Testing

Last line of defence

Page 5: Official EmersonProcess PPT Presentation Template...27-Jun-01, Slide 18 Increased Diagnostic Coverage Diagnose mechanical failures before they happen AMS ValveLink uploads PST results

[File Name or Event] Emerson Confidential 27-Jun-01, Slide 6

The Challenges faced

Consider random as

well as systematic

integrity

Lack of Standards

Monitor and test with

system in service? (Fast

closing)

What if failures are

detected by diagnostic?

Regulations a moving target

IPPC Directives 2008/1/EC

20+20+20 by 2020

Compliance with

current functional

safety legislation for

all elements of the SIF

Handling of multiple

vendors / consultants

Validation of SRS

Defining SRS and

ensure requirements

are followed through

Page 6: Official EmersonProcess PPT Presentation Template...27-Jun-01, Slide 18 Increased Diagnostic Coverage Diagnose mechanical failures before they happen AMS ValveLink uploads PST results

[File Name or Event] Emerson Confidential 27-Jun-01, Slide 7

Challenges Engineering a HIPPS - The causes of failure and the answers

Random failures

Occur due to:

– Inappropriate application

– Bad design

– Fatigue

Reduced by

– Material quality

– Consistent appropriate design

– Performance monitoring

Everything breaks eventually

Systematic failures

Occur due to:

– Designed in

– Engineered in

– Procedural

Reduced by:

– Better processes

– Regular Verification

– Consistent behaviour

People make mistakes

All components of any solution can fail dangerously

Page 7: Official EmersonProcess PPT Presentation Template...27-Jun-01, Slide 18 Increased Diagnostic Coverage Diagnose mechanical failures before they happen AMS ValveLink uploads PST results

[File Name or Event] Emerson Confidential 27-Jun-01, Slide 8

The causes of failure and the answers

Ensure structure and management of all activities

Identify activities and objectives

Manage verification steps

Control the effect of people in every activity

Systematic failures Answer - The safety lifecycle

Random Failures Answer – Safety Integrity Levels

Risk inherent in the process

Tolerable risk region

Other risk

reduction

measures

Risk reduction

by Safety

Instrumented

System

Incre

asin

g r

isk

Residual risk

Measure risk

Quantify instrumented risk reduction target – SIL

Match design to SIL – PFD etc

Monitor performance, adjust design

Control the effect of dangerous failures

Page 8: Official EmersonProcess PPT Presentation Template...27-Jun-01, Slide 18 Increased Diagnostic Coverage Diagnose mechanical failures before they happen AMS ValveLink uploads PST results

[File Name or Event] Emerson Confidential 27-Jun-01, Slide 10

Certified SIS Products and Processes

IEC 61508 Certified Products: – DeltaV SIS, Rosemount, Bettis, Fisher, ASCO and Virgo are IEC 61508 Certified

IEC 61511 Certified Processes: – Global Investment in the development of “SIS Processes”

– All Integration Centers are fully certified to IEC 61511

– Provide a single, worldwide framework for consistent designs

Operation

Implementation

Analysis

Page 9: Official EmersonProcess PPT Presentation Template...27-Jun-01, Slide 18 Increased Diagnostic Coverage Diagnose mechanical failures before they happen AMS ValveLink uploads PST results

[File Name or Event] Emerson Confidential 27-Jun-01, Slide 11

Challenges on a product level - Valve

Closing Speed < 2” regardless of size

Critical on larger diameters / higher ratings

- Inertia

- Repeatability /Reliability

Must not affect tightness

- Linear speed

Page 10: Official EmersonProcess PPT Presentation Template...27-Jun-01, Slide 18 Increased Diagnostic Coverage Diagnose mechanical failures before they happen AMS ValveLink uploads PST results

[File Name or Event] Emerson Confidential 27-Jun-01, Slide 12

Challenges on a product level - Valves

Inertia

Drive train design criticalities

- Torque impulses

- Ball – stem coupling

- Slot vs Spline

- Surface treatments

- Shear keys

Page 11: Official EmersonProcess PPT Presentation Template...27-Jun-01, Slide 18 Increased Diagnostic Coverage Diagnose mechanical failures before they happen AMS ValveLink uploads PST results

[File Name or Event] Emerson Confidential 27-Jun-01, Slide 13

Challenges on a product level - Valves

Repeatability – Life Cycle

- Design criticalities

- Materials

- Overlays

- Bushings

Page 12: Official EmersonProcess PPT Presentation Template...27-Jun-01, Slide 18 Increased Diagnostic Coverage Diagnose mechanical failures before they happen AMS ValveLink uploads PST results

[File Name or Event] Emerson Confidential 27-Jun-01, Slide 14

Challenges on a product level

Tightness reliability

- Actuator parameters

- Over-speed control

- End-stroke dampener

- Seat design

- Seat /Seal materials and mating

Page 13: Official EmersonProcess PPT Presentation Template...27-Jun-01, Slide 18 Increased Diagnostic Coverage Diagnose mechanical failures before they happen AMS ValveLink uploads PST results

[File Name or Event] Emerson Confidential 27-Jun-01, Slide 15

Challenges on a product level - Valves

Design Know How

- Valve Construction

- Trim

- Contact areas

- Automation

Page 14: Official EmersonProcess PPT Presentation Template...27-Jun-01, Slide 18 Increased Diagnostic Coverage Diagnose mechanical failures before they happen AMS ValveLink uploads PST results

[File Name or Event] Emerson Confidential 27-Jun-01, Slide 17

Challenges on a product level

VOS - Valve Operating System

• Diagnostic on Fast Acting ESDV

applications

• High Diagnostic Coverage

• Test of all critical control elements

in the shut down circuit with the

system in Service

Page 15: Official EmersonProcess PPT Presentation Template...27-Jun-01, Slide 18 Increased Diagnostic Coverage Diagnose mechanical failures before they happen AMS ValveLink uploads PST results

[File Name or Event] Emerson Confidential 27-Jun-01, Slide 18

Increased Diagnostic Coverage

Diagnose mechanical failures before

they happen

AMS ValveLink uploads PST results

for analysis

Additional diagnostics

Volume Booster tested as part of

PST

Solenoids testing (50-100mSec)

Friction build-up

Valve shaft shear

Page 16: Official EmersonProcess PPT Presentation Template...27-Jun-01, Slide 18 Increased Diagnostic Coverage Diagnose mechanical failures before they happen AMS ValveLink uploads PST results

[File Name or Event] Emerson Confidential 27-Jun-01, Slide 19

Logic Solver

Simple “HMI”

Status Lamps

Override Keyswitches

Challenges on a product level

Certified with SC3 (SIL3)

Partial Stroke Capability

Comms interface with DCS

HART Pass-through

Smart SISTM Diagnostics

Page 17: Official EmersonProcess PPT Presentation Template...27-Jun-01, Slide 18 Increased Diagnostic Coverage Diagnose mechanical failures before they happen AMS ValveLink uploads PST results

[File Name or Event] Emerson Confidential 27-Jun-01, Slide 20

Challenges on a product level

Logic Solvers can also be

mounted “Locally” on the HIPPS

or

As part of a skid.

Pre-wired, pre-tested, Validated

and with a fiber-Optic connection

back to a Central SCADA system

Zone 2 in a IP54/65 enclosure or

Zone 1 in a EEx d enclosure

Page 18: Official EmersonProcess PPT Presentation Template...27-Jun-01, Slide 18 Increased Diagnostic Coverage Diagnose mechanical failures before they happen AMS ValveLink uploads PST results

[File Name or Event] Emerson Confidential 27-Jun-01, Slide 21

Pressure Sensors Plugged Impulse line (SPM)

Systematic Capability: SC3

Advanced Diagnostics (DA2)

Rosemount 3051S

High Integrity Manifold – 3 tapings

Block-Bleed-Block for test

Single Isolation Key for 3 sensors

ATEX Junction Boxes

Challenges on a product level

Page 19: Official EmersonProcess PPT Presentation Template...27-Jun-01, Slide 18 Increased Diagnostic Coverage Diagnose mechanical failures before they happen AMS ValveLink uploads PST results

[File Name or Event] Emerson Confidential 27-Jun-01, Slide 22

A Solution addressing all challenges

• Certified Systematic Capability3

• The HIPPS Design use Certified

procedures acc. to IEC 61511

• Single Supplier Management

• Verification of SIL

• IEC 61 508 and 511

compliant

• Proof test and Inspection plan

• Calibration and Operation

records

• IOM for HIPPS

• Compliance report to ensure

Safety Lifetime is addressed

• Validation if required

Page 20: Official EmersonProcess PPT Presentation Template...27-Jun-01, Slide 18 Increased Diagnostic Coverage Diagnose mechanical failures before they happen AMS ValveLink uploads PST results

[File Name or Event] Emerson Confidential 27-Jun-01, Slide 23

Questions

Page 21: Official EmersonProcess PPT Presentation Template...27-Jun-01, Slide 18 Increased Diagnostic Coverage Diagnose mechanical failures before they happen AMS ValveLink uploads PST results

[File Name or Event] Emerson Confidential 27-Jun-01, Slide 24

Back up Slides

Page 22: Official EmersonProcess PPT Presentation Template...27-Jun-01, Slide 18 Increased Diagnostic Coverage Diagnose mechanical failures before they happen AMS ValveLink uploads PST results

[File Name or Event] Emerson Confidential 27-Jun-01, Slide 25

S

ingle

Supplie

r P

roje

ct M

anagem

ent

•In

sta

llatio

n, O

pe

ratio

n &

Ma

inte

na

nce

•Pro

of Te

st a

nd

In

sp

ectio

n P

lan

•Ca

libra

tio

n R

eco

rds

•Op

era

tio

n R

eco

rds

Do

cu

me

nta

tio

n P

acka

ge

SIL

Ve

rifica

tio

n R

ep

ort

Complete HIPPS Solution

PSS – Digital control

• DeltaV – SIS Logic Solver

Rosemount Pressure Sensors

Final Element

Valve Automation

• Actuation – Bettis

• Pneumatic/Hydraulic Controls (Solenoids

etc)

• Fisher DVC - Valve Control for PST and

diagnostic

Valve

Page 23: Official EmersonProcess PPT Presentation Template...27-Jun-01, Slide 18 Increased Diagnostic Coverage Diagnose mechanical failures before they happen AMS ValveLink uploads PST results

[File Name or Event] Emerson Confidential 27-Jun-01, Slide 26

Products photo

Page 24: Official EmersonProcess PPT Presentation Template...27-Jun-01, Slide 18 Increased Diagnostic Coverage Diagnose mechanical failures before they happen AMS ValveLink uploads PST results

[File Name or Event] Emerson Confidential 27-Jun-01, Slide 27

Products photo

Page 25: Official EmersonProcess PPT Presentation Template...27-Jun-01, Slide 18 Increased Diagnostic Coverage Diagnose mechanical failures before they happen AMS ValveLink uploads PST results

[File Name or Event] Emerson Confidential 27-Jun-01, Slide 28

Products photo

Page 26: Official EmersonProcess PPT Presentation Template...27-Jun-01, Slide 18 Increased Diagnostic Coverage Diagnose mechanical failures before they happen AMS ValveLink uploads PST results

[File Name or Event] Emerson Confidential 27-Jun-01, Slide 29

Products photo

Page 27: Official EmersonProcess PPT Presentation Template...27-Jun-01, Slide 18 Increased Diagnostic Coverage Diagnose mechanical failures before they happen AMS ValveLink uploads PST results

[File Name or Event] Emerson Confidential 27-Jun-01, Slide 30

Products photo