39
OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL COMPLEX, 7-9 NORMAN ROAD KINGSTON CSO JAMAICA 1

OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

  • Upload
    lamtu

  • View
    217

  • Download
    1

Embed Size (px)

Citation preview

Page 1: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL COMPLEX, 7-9 NORMAN ROAD

KINGSTON CSO JAMAICA

1

Page 2: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

WHO WE AREOn the 7th July 2011 MARINE SAFETY JAMAICA LTD was given authorization by

the Government of Jamaica through the Maritime Authority of Jamaica to

conduct business. The business was Registered on 1st November 2011, Life Raft

Station built and completed by the end of May and began operations on 1st July

2012. Marine Safety Jamaica Limited supplies equipment and maintenance for

both vessels and offshore structures.

We foster business relationships with local and international expertise that offers

world-class products and services to the maritime industry. Our customers rely

on us to understand their business processes in order to offer appropriate

solutions that add both value and assurance to their stakeholders.

Marine Safety Jamaica Ltd caters to vessels visiting our ports, Ship Management

Companies (local and overseas), local Government entities and Jamaica

registered vessels.

An investment of 1million USD based on the future of the Logistic Hub.

2

Page 3: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

CERTIFICATIONSSTATION CERTIFICATION:MARITIME AUTHORITY OF JAMAICA

VIKING LIFE SAVING EQUIPMENT

ZODIAC – SURVITEC

DSB – SURVITEC

TECHNICIAN CERTIFICATION:VIKING

ZODIAC

DSB

3

Page 4: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

WHAT WE DOService and certify Life Rafts, Life

Jackets and Immersion Suits

Servicing of Inflatable Boats

Supply Solas Approved marine safety

items to customers locally and overseas

Hydro Testing of cylinders, examples:

Medical Cylinders, C02 Cylinders

4

Page 5: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

BRANDS WE REPRESENT

VIKING

DSB

ZODIAC

Through our associate company in

Trinidad (MARINE CONSULTANT

LIMITED) We represent other brands.

(Please visit http//www.mcl.co.tt for

further information)

5

Page 6: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

PICTURE OF LIFE RAFT BEFORE SERVICING.

6

Page 7: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

THE UNPACKING OF THE LIFE RAFT.

7

Page 8: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

LIFE RAFT FULLY REMOVED FROM CANISTER

8

Page 9: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

PAINTER LINE CONNECTED TO FIRING PIN.

9Painter line must be disconnected before the servicing of the life raft.

Page 10: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

LIFE RAFT FULLY INFLATED.

10

Page 11: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

LIFE RAFT FULLY INFLATED. While life raft is fully

inflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve (PRV), one hour later we do another pressure reading.

The raft must not loose more than 5% of the closing pressure.

11

Page 12: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

REPACKING OF LIFE RAFT When repacking the life raft all date replaceable item

must put back in correct location and secure properly.

Co2 cylinder must be secure back to the raft and high pressure hose must be re-attach to co2 cylinder and torque.

Raft has been deflated by vacuuming.

Light must be connected before the rolling of the life raft.

Life raft must be rolled, put in canister and canister secure with a bursting band.

12

Page 13: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

REPACKING OF LIFE RAFT.

13

,

When folded the life raft should look like this.

Page 14: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

REPACKING OF LIFE RAFT.

When completed the life raft should look like this.14

Page 15: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

WHAT WE SELL

15

Page 16: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

LIFEJACKET

Viking Inflatable Stern Rigid

16

Page 17: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

IRB’S DSB INFLATABLE RESCUE BOAT

17

Page 18: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

VIKING LIFE RAFT

18

Page 19: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

DSB LIFE RAFT

19

Page 20: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

IMMERSION SUIT

20

Page 21: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

PYROTECHNICS

Line Throwing Device Man Over Board Light &

Smoke Signal

21

Page 22: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

PYROTECHNICS

Parachute Rocket Smoke Signal

22

Page 23: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

PYROTECHNICS

Red Hand flareHand flare, Parachute rocket

and smoke signal

23

Page 24: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

LIFE RING AND LIGHT Life buoy/ring L-90 Light

24

Page 25: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

WATER, RATION & FIRST AID KIT

25

Page 26: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

FIRE EQUIPMENT CO2 Fire Extinguisher Foam Fire Extinguisher

26

Page 27: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

FIRE EQUIPMENT Fire Reel Cabinet Fire Hose

27

Page 28: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

FIRE EQUIPMENT

Water Fire Extinguisher ABC Fire Extinguisher

28

Page 29: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

COMPASSBinnacle Compass

29

Page 30: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

EMERGENCY ESCAPE BREATHING DEVICE

EEBD in its case EEBD in operation

30

Page 31: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

DATE REPLACABLE ITEMSAt every service all date replaceable items must be checked to see when it expired.

For example:

Water

Ration

Pyrotechnics

Torch batteries

First aid kit

Glue

Hammer release unit

Seasick tablets 31

Page 32: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

CO2 CYLINDERAt every service co2

cylinder must be weight tested to make sure that it contain the correct amount of charge to inflate the raft if needed.

32

Page 33: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

GENERAL MANAGER MR. SILBOURNE CLARKE

33

Page 34: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

Human Resource and Admin Coordinator. Sharon Reid

34

Page 35: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

Life raft Technician.Gavin Campbell

35

Page 36: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

Life raft Technician.Noel McKenzie

36

Page 37: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

Life raft Technician.Michael Edwards

37

Page 38: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

Technician in Fire Department.Yackeem Brown

38

Page 39: OFFICE ADDRESS: UNIT R1-3 SAGICOR INDUSTRIAL · PDF fileinflated we do a leak test by checking the pressure as soon as air stop escaping through the pressure relief valve ... Co2 cylinder

CONTACT INFORMATIONOffice: (876) 759-1824

(876) 759-4978

Mobile: (876) 354-6226

Email: [email protected]

Facebook Page: Marine Safety

Jamaica Limited

39