2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety glazing materials: 1. Glazing in swinging doors except jalousies (see Section 2406.4.1). 2. Glazing in fixed and sliding panels of sliding door assemblies and panels in sliding and bifold closet door assemblies. 3. Glazing in storm doors. 4. Glazing in unframed swinging doors. 5. Glazing in doors and enclosures for hot tubs, whirlpools, saunas, steam rooms, bathtubs & showers. Glazing in any portion of a building wall enclosing these compartments where the bottom exposed edge of the glazing is less than 60 inches above a standing surface. 6. Glazing in an individual fixed or operable panel adjacent to a door where the nearest exposed edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface. Exceptions: 1. Panels where there is an intervening wall or other permanent barrier between the door and glazing. 2. Where access through the door is to a closet or storage area 3 feet or less in depth. Glazing in this application shall comply with Section 2406.4, Item 7. 3. Glazing in walls perpendicular to the plane of the door in a closed position other than the wall towards which the door swings when opened in one- and two- family dwellings or within dwelling units in Group R-2. 7. Glazing in an individual fixed or operable panel, other than in those locations described in preceding Items 5 and 6, which meets all of the following conditions: 7.1. Exposed area of an individual pane greater than 9 sq. ft. 7.2. Exposed bottom edge less than 18 inches above the floor. 7.3. Exposed top edge greater than 36 inches above the floor; and 7.4. One or more walking surface(s) within 36 inches horizontally of the plane of the glazing. Exception: Safety glazing for condition for Item 7 is not required for the following installations: 1. A protective bar 1 1/2 inches or more in height, capable of withstanding a horizontal load of 50 plf without contacting the glass, is installed on the accessible sides of the glazing 34 inches to 38 inches above the floor. 2. The outboard pane in insulating glass units or multiple glazing where the bottom exposed edge of the glass is 25 ft or more above any grade, roof, walking surface or other horizontal or sloped (within 45 degrees of horizontal) surface adjacent to the glass exterior. 8. Glazing in guards and railings, including structural baluster panels and nonstructural in-fill panels, regardless of area or height above a walking surface. 9. Glazing in walls and fences enclosing indoor and outdoor swimming pools, hot tubs and spas where all of the following conditions are present: 9.1. The bottom edge of the glazing on the pool or spa side is less than 60 inches above a walking surface on the pool or spa side of the glazing; and 9.2. The glazing is within 60 inches horizontally of the water's edge of a swimming pool or spa. 10. Glazing adjacent to stairways, landings and ramps within 36 inches horizontally of a walking surface; when the exposed surface of the glass is less than 60 omcjes above the plane of the adjacent walking surface. 11. Glazing adjacent to stairways within 60 inches horizontally of the bottom tread of a stairway in any direction when the exposed surface of the glass is less than 60 inches above the nose of the tread. Exception: Safety glazing for Item 10 or 11 is not required for the following installations where: 1. The side of a stairway, landing or ramp which has a guard or handrail, including balusters or in-fill panels, complying with the provisions of Sections 1013 and 1607.7; and 2. The plane of the glass is greater than 18 inches from the railing. 2406.4.1 EXCEPTIONS. The following products, materials and uses shall not be considered specific hazardous locations: 1. Openings in doors through which a 3-inch sphere is unable to pass. 2. Decorative glass in Section 2406.4, Item 1, 6 or 7. 3. Glazing material used as curved glazed panels in revolving doors. 4. Commercial refrigerated cabinet glazed doors. 5. Glass block panels complying with Section 2101.2.5. 6. Louvered windows and jalousies complying with the requirements of Section 2403.5. 7. Mirrors and other glass panels mounted or hung on a surface that provides a continuous backing support. = Tempered 715.4.3 DOOR ASSEMBLIES IN CORRIDORS AND SMOKE BARRIERS. Fire door assemblies required to have a minimum fire-protection rating of 20 minutes where located in corridor walls or smoke barrier walls having a fire-resistance rating in accordance with Table 715.4 shall be tested in accordance with NFPA 252 or UL 10C without the hose stream test. Exceptions: 1. Viewports that require a hole not larger than 1 inch in diameter through the door, have at least a 0.25-inch-thick glass disc and the holder is of metal that will not melt out where subject to temperatures of 1,700°F. 2. Corridor door assemblies in occupancies of Group I-2 shall be in accordance with Section 407.3.1. 3. Unprotected openings shall be permitted for corridors in multitheater complexes where each motion picture auditorium has at least one-half of its required exit or exit access doorways opening directly to the exterior or into an exit passageway. 4. Horizontal sliding doors in smoke barriers that comply with Sections 408.3 and 408.8.4 in occupancies in Group I-3. 715.4.3.1 SMOKE AND DRAFT CONTROL. Fire door assemblies shall also meet there requirements for a smoke and draft control door assembly tested in accordance with UL 1784. The air leakage rate of the door assembly shall not exceed 3.0 cubic feet per minute per square foot of door opening at 0.10 inch of water for bothe the ambient temperature and elevated temperature tests. Louvers shall be prohibited. Installation of smoke doors shall be in accordance with NFPA 105. 715.4.3.2 GLAZING IN DOOR ASSEMBLIES. In a 20-minute fire door assembly, the glazing material in the door itself shall have a minimum fire-protection-rated glazing of 20 minutes and shall be exempt from the hose stream test. Glazing material in any other part of the door assembly, including transom lights and sidelights, shall be tested in accordance with NFPA 257 or UL9, including the hose stream test, in accordance with Section 715.5. DOOR HARDWARE: At all units, lever handle passage sets will be installed on entry doors. Lever handle passage sets to be installed on all unit interior and exterior doors. HARDWARE: (to be specified brands or equal) Lock Hardware: "Kwikset, Tylo Series". At front door of all units provide 1 passage set, 1 keyed deadbolt (min. 1" throw), 1 keyless deadbolt (min. 1" throw). Both strike plates installed using 3" screws One 180° door viewer and door knocker also at front entry. At sliding glass doors pin locks must be installed not more than 4'-8" from the floor or "Fortress Patio Door Lock" At glass patio doors provide 1 passage lock and 1 keyless deadbolt (min. 1" throw w/strike plate installed using 3" screws). Deadbolts and locks to be construction keyed only. All deadbolts and locks are to be independently keyed when turned from construction. Note: lock supplier to send master keys directly to owner. Do not send to job. NOTE: Units front doors shall be operable from the inside without the use of a key or any special knowledge or effort. NOTE: All windows should be double-pane insulating, low-e windows. All exterior doors should be insulated. NOTE: See specifications for interior and exterior finishes. NOTE: See sheet A1.3-A1.6 for accessibility guidelines. NOTE: Accessible and public common use areas require that door surfaces within 10" of the floor be a smooth surface on the push side. (Including residential entry doors). NOTE: The unlatching of any leaf shall not require more than one operation except as provided in Section 1008.1.9.5. NOTE: Smoke doors on elevators are self closing and hold opens mag locks with 180° hinges connected to fire alarm system. HARDWARE NOTES: 1) ALL HARDWARE SHALL COMPLY WITH UFAS, (UNIFORM FEDERAL ACCESSIBLE STANDARDS) UNLESS SPECIFIED OTHERWISE. 2) HARDWARE FOR LABELED FIRE DOORS AND EXIT DOORS: CONFORM TO REQUIREMENTS OF NFPA 80 FOR LABELED FIRE DOORS AND TO NFPA 101 FOR EXIT DOORS, AS WELL AS TO OTHER REQUIREMENTS SPECIFIED. PROVIDE HARDWARE LIST BY UL. 3) SEE SPECIFICATIONS FOR DOOR HARDWARE 4) TEMPERED GLASS PER IBC SECTION 2406.4.2 & 2406.4.3 5) INTERIOR CLUB PRIVACY LOCK-SETS MUST BE PUSH-BUTTON TYPE. DEFINITIONS CRS - COLD ROLLED STEEL C SERIES - INTERNALLY REINFORCED WITH STEEL HAT CHANNEL AND VOIDS FILLED WITH FIBERGLASS INSULATION UNIT HARDWARE SCHEDULE HARWARE SET #1 (UNIT ENTRY) 3 - SPRING HINGE 1 - U.L. KEYLESS DEADBOLT 1 - U.L. SGL. CYL. DEADBOLT 1 - U.L. LEVER PASSAGE 1 - KNOCKER/VIEWER 1 - U.L. DOOR VIEWER 1 - H.D. FLEX DOOR STOP 1 - THRESHOLD 1 - WEATHERSTRIPPING HARDWARE SET #2 (UNIT PATIO) 3 - HINGE 1 - KEYLESS DEADBOLT 1 - SGL. CYL. DEADBOLT 1 - LEVER PASSAGE 1 - H.D. FLEX DOOR STOP 1 - THRESHOLD 1 - WEATHERSTRIPPING HARDWARE SET #3 (EXT. STORAGE) 3 - HINGE 1 - U.L. LEVER KEYLOCK 1 - SPRING CRASH WIND CHAIN 1 - THRESHOLD 1 - WEATHERSTRIPPING HARDWARE SET #4 (INT MECH) 3 - HINGE 1 - LEVER KEYLOCK 1 - H.D. FLEX DOOR STOP HARDWARE SET #5 (BED/BATH) 3 - HINGE 1 - LEVER PRIVACY 1 - H.D. FLEX DOOR STOP HARDWARE SET #6 (CLOSET) 3 - HINGE 1 - LEVER PASSAGE 1 - H.D. FLEX DOOR STOP HARDWARE SET #7 (CLOSET DOUBLE DOOR) 3 - HINGE 2 - LEVER DUMMY 2 - H.D. FLEX DOOR STOP COMMON HARDWARE SCHEDULE HARWARE SET #8 (CLUB RR) 4 - BALL BEARING HINGES 1 - LEVER PRIVACY 1 - PUSH/PULL PLATE 1 - DOOR CLOSER 1 - CONCAVE WALL BUMPER 1 - THRESHOLD 1 - DOOR SWEEP HARDWARE SET #9 (STORAGE/KEYTRACK) 4 - BALL BEARING HINGES 1 - SGL. CYL. DEADBOLT 1 - LEVER PASSAGE HARDWARE SET #10 (A/C CLOSET) 4 - BALL BEARING HINGES 1 - SGL. CYL. DEADBOLT 1 - LEVER PASSAGE HARDWARE SET #11 (STAIR/CORRIDOR) 3 - BALL BEARING HINGES 1 - FIRE RATED RIM PANIC DEVICE 1 - PANIC DEVICE TRIM-PASSAGE FUNCTION 1 - DOOR CLOSER - FULL COVER 1 - CONCAVE WALL STOP 1 - THRESHOLD 1 - DOOR SWEEP 1 - SMOKE SEAL HARDWARE SET #12 (CORRIDOR STORAGE) 4 - BALL BEARING HINGES 1 - STOREROOM LEVER 1 - DOOR CLOSER 1 - CONCAVE WALL STOP 1 - THRESHOLD 1 - DOOR SWEEP 1 - SMOKE SEAL HARDWARE SET #13 (FIRE DOORS) 8 - BALL BEARING HINGES 2 - FIRE RATED VERTICAL PANIC DEVICE 2 - PANIC DEVICE TRIM-PASSAGE FUNCTION 2 - DOOR CLOSER 2 - ELECTRO-MAG HOLD OPENS 2 - THRESHOLD 2 - DOOR SWEEPS 2 - SMOKE SEAL T NOTE: Install electronic keyless entry in all unit entry doors & use HID chip for all building access and amenity areas, both programmable and readable by KABA system. NOTE: Undercut all doors 1" for return air balance system. Reference MEP. NOTE: Provide 3% transparency window shades in living areas and 1% shades in bedrooms. 1 2 3 4 5 6 8 9 10 11 12 13 14 15 16 17 18 19 23 26 27 28 29 30 T T T T T 3' - 8" 2' - 0" 0' - 10" 1' - 1" 0' - 10" 1' - 1" 20 24 FIRE SAFETY GLAZING EMERGENCY EGRESS 32 7 33 34 35 A B C D E F T T T T T T ISSUED FOR PERMIT ISSUED FOR BID ISSUED FOR CONSTRUCTION DATE DESCRIPTION SHEET DRAWN BY: CHECKED BY: PROJECT #: 8/31/2016 9:41:41 AM A3.1 CWS 11/08/13 BAT MEM 13-1926 DOOR & WINDOW SCHEDULE WEST 5TH STREET 1301 W. 5TH ST. AUSTIN, TX 78703 9606 NORTH MOPAC EXPRESSWAY, SUITE 500, AUSTIN TX 78759 08/31/16 08/15/16 Door Schedule Type Mark Description Material Door Door Fire Rating Location Width Height 1 FLUSH SINGLE SC 3' - 0" 8' - 0" 20 MIN. UNIT ENTRY 2 1 PANEL SINGLE 3' - 0" 8' - 0" n/a 3 1 PANEL SINGLE HC 2' - 10" 8' - 0" n/a UNIT 4 1 PANEL SINGLE HC 2' - 6" 8' - 0" n/a UNIT 5 1 PANEL SINGLE HC 2' - 0" 8' - 0" n/a UNIT 6 1 PANEL SINGLE LOUVERED HC 2' - 6" 8' - 0" n/a UNIT 7 1 PANEL SINGLE LOUVERED HC 2' - 10" 8' - 0" n/a UNIT 8 FLUSH SINGLE HC 2' - 10" 8' - 0" n/a UNIT 9 FLUSH SINGLE HC 3' - 0" 8' - 0" n/a UNIT 10 1 PANEL DOUBLE HC 5' - 0" 8' - 0" n/a UNIT 11 1 PANEL DOUBLE HC 4' - 0" 8' - 0" n/a UNIT 12 1 PANEL DOUBLE HC 3' - 0" 8' - 0" n/a UNIT 13 1 PANEL DOUBLE HC 5' - 0" 8' - 0" n/a UNIT 14 1 PANEL DOUBLE SLIDING HC 6' - 0" 8' - 0" n/a UNIT 15 CRS C SERIES FLUSH HM 3' - 0" 8' - 0" 3 hr. CORRIDOR 16 GLASS LITE SINGLE HM / TEMPERED 3' - 0" 8' - 0" n/a UNIT/CLUB 17 STOREFRONT SINGLE TEMPERED 3' - 0" 8' - 0" n/a CLUB 18 GLASS LITE DOUBLE SLIDING HM / TEMPERED 6' - 0" 8' - 0" n/a UNIT 19 GLASS LITE SINGLE W/SIDELIGHT HM / TEMPERED 6' - 0" 8' - 0" n/a CLUB 23 STOREFRONT DOUBLE TEMPERED 5' - 0" 8' - 0" n/a CLUB 24 STOREFRONT DOUBLE SLIDING TEMPERED 6' - 0" 8' - 0" n/a CLUB 26 FLUSH SINGLE HM 3' - 0" 6' - 8" 20 min. GARAGE / 1ST FLOOR 27 FLUSH SINGLE HM 3' - 0" 8' - 0" n/a GARAGE / 1ST FLOOR 28 FLUSH SINGLE VISION HM 3' - 0" 8' - 0" 90 min. STAIR 29 FLUSH SINGLE VISION HM 3' - 0" 6' - 8" 90 min. STAIR 30 FLUSH DOUBLE HM 5' - 0" 8' - 0" n/a GARAGE / 1ST FLOOR 32 GARAGE HM 24' - 0" 11' - 3" n/a GARAGE / 1ST FLOOR 33 Accordian-Type Fire Doors HM 6' - 6 7/8" 8' - 6 1/2" 90 min. CLUB 34 ELEVATOR SMOKE DOOR HM 3' - 8" 8' - 0" 90 min. ELEVATOR 35 FLUSH SINGLE HM 3' - 0" 8' - 0" 90 min. TEMP. 2 HR FIRE WALL Window Schedule Type Mark R.O. Type Material Finish Fire Rating Description Location Width Height A 6' - 0" 6' - 0" Slider Aluminum Bronze n/a Double Pane Insulated Low E Unit B 4' - 0" 6' - 0" Slider Aluminum Bronze n/a Double Pane Insulated Low E Unit C 2' - 0" 8' - 0" Fixed Aluminum Bronze n/a Double Pane Insulated Low E Unit D 6' - 0" 1' - 6" Fixed Aluminum Bronze n/a Double Pane Insulated Low E Unit E 7' - 6" 1' - 6" Fixed Aluminum Bronze n/a Double Pane Insulated Low E Unit F 6' - 0" 8' - 0" Fixed Aluminum Bronze n/a Double Pane Insulated Low E Unit 1 1 1 1 No. Revision Date 1 REV 1 Date 1

odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

2012 International Building Code2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locationsrequiring safety glazing materials:

1. Glazing in swinging doors except jalousies (see Section 2406.4.1).2. Glazing in fixed and sliding panels of sliding door assemblies and panels in sliding and bifold closetdoor assemblies.3. Glazing in storm doors.4. Glazing in unframed swinging doors.5. Glazing in doors and enclosures for hot tubs, whirlpools, saunas, steam rooms, bathtubs &showers. Glazing in any portion of a building wall enclosing these compartments where the bottomexposed edge of the glazing is less than 60 inches above a standing surface.6. Glazing in an individual fixed or operable panel adjacent to a door where the nearest exposededge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position andwhere the bottom exposed edge of the glazing is less than 60 inches above the walking surface. Exceptions:

1. Panels where there is an intervening wall or other permanent barrierbetween the door and glazing.

2. Where access through the door is to a closet or storage area 3 feet or less in depth.Glazing in this application shall comply with Section 2406.4, Item 7. 3. Glazing in walls perpendicular to the plane of the door in a closed position other than the wall towards which the door swings when opened in one- and two-family dwellings or within dwelling units in Group R-2.

7. Glazing in an individual fixed or operable panel, other than in those locations described inpreceding Items 5 and 6, which meets all of the following conditions: 7.1. Exposed area of an individual pane greater than 9 sq. ft. 7.2. Exposed bottom edge less than 18 inches above the floor. 7.3. Exposed top edge greater than 36 inches above the floor; and 7.4. One or more walking surface(s) within 36 inches horizontally of the plane of the glazing. Exception: Safety glazing for condition for Item 7 is not required for the following installations: 1. A protective bar 1 1/2 inches or more in height, capable of withstanding a horizontal load of 50 plf without contacting the glass, is installed on the accessible sides of the glazing 34 inches to 38 inches above the floor. 2. The outboard pane in insulating glass units or multiple glazing where the bottom exposed edge of the glass is 25 ft or more above any grade, roof, walking surface or other horizontal or sloped (within 45 degrees of horizontal) surface adjacent to the glass exterior.8. Glazing in guards and railings, including structural baluster panels and nonstructural in-fill panels,regardless of area or height above a walking surface.9. Glazing in walls and fences enclosing indoor and outdoor swimming pools, hot tubs and spas whereall of the following conditions are present: 9.1. The bottom edge of the glazing on the pool or spa side is less than 60 inches above a walking surface on the pool or spa side of the glazing; and 9.2. The glazing is within 60 inches horizontally of the water's edge of a swimming pool or spa.10. Glazing adjacent to stairways, landings and ramps within 36 inches horizontally of a walkingsurface; when the exposed surface of the glass is less than 60 omcjes above the plane of theadjacent walking surface.11. Glazing adjacent to stairways within 60 inches horizontally of the bottom tread of a stairway inany direction when the exposed surface of the glass is less than 60 inches above the nose of thetread. Exception: Safety glazing for Item 10 or 11 is not required for the following installations where: 1. The side of a stairway, landing or ramp which has a guard or handrail, including balusters or in-fill panels, complying with the provisions of Sections 1013 and 1607.7; and 2. The plane of the glass is greater than 18 inches from the railing.

2406.4.1 EXCEPTIONS. The following products, materials and uses shall not be considered specifichazardous locations:

1. Openings in doors through which a 3-inch sphere is unable to pass.2. Decorative glass in Section 2406.4, Item 1, 6 or 7.3. Glazing material used as curved glazed panels in revolving doors.4. Commercial refrigerated cabinet glazed doors.5. Glass block panels complying with Section 2101.2.5.6. Louvered windows and jalousies complying with the requirements of Section 2403.5.7. Mirrors and other glass panels mounted or hung on a surface that provides a continuous backingsupport.

= Tempered

715.4.3 DOOR ASSEMBLIES IN CORRIDORS AND SMOKE BARRIERS. Fire door assembliesrequired to have a minimum fire-protection rating of 20 minutes where located in corridor walls orsmoke barrier walls having a fire-resistance rating in accordance with Table 715.4 shall be testedin accordance with NFPA 252 or UL 10C without the hose stream test.

Exceptions:1. Viewports that require a hole not larger than 1 inch in diameter through the door, have at least a0.25-inch-thick glass disc and the holder is of metal that will not melt out where subject totemperatures of 1,700°F.2. Corridor door assemblies in occupancies of Group I-2 shall be in accordance with Section 407.3.1.3. Unprotected openings shall be permitted for corridors in multitheater complexes where eachmotion picture auditorium has at least one-half of its required exit or exit access doorways openingdirectly to the exterior or into an exit passageway.4. Horizontal sliding doors in smoke barriers that comply with Sections 408.3 and 408.8.4 inoccupancies in Group I-3.

715.4.3.1 SMOKE AND DRAFT CONTROL. Fire door assemblies shall also meet there requirementsfor a smoke and draft control door assembly tested in accordance with UL 1784. The air leakage rateof the door assembly shall not exceed 3.0 cubic feet per minute per square foot of door opening at 0.10 inch of water for bothe the ambient temperature and elevated temperature tests.Louvers shall be prohibited. Installation of smoke doors shall be in accordance with NFPA 105.

715.4.3.2 GLAZING IN DOOR ASSEMBLIES. In a 20-minute fire door assembly, the glazingmaterial in the door itself shall have a minimum fire-protection-rated glazing of 20 minutes and shall be exempt from the hose stream test. Glazing material in any other part of the door assembly,including transom lights and sidelights, shall be tested in accordance with NFPA 257 or UL9,including the hose stream test, in accordance with Section 715.5.

DOOR HARDWARE: At all units, lever handle passage sets will be installed on entry doors. Lever handle passage sets to be installed on all unit interior and exterior doors.

HARDWARE: (to be specified brands or equal) Lock Hardware: "Kwikset, Tylo Series". Atfront door of all units provide 1 passage set, 1 keyed deadbolt (min. 1" throw), 1 keylessdeadbolt (min. 1" throw). Both strike plates installed using 3" screws

One 180° door viewer and door knocker also at front entry. At sliding glass doorspin locks must be installed not more than 4'-8" from the floor or "Fortress Patio Door Lock"

At glass patio doors provide 1 passage lock and 1 keyless deadbolt (min. 1" throww/strike plate installed using 3" screws).

Deadbolts and locks to be construction keyed only. All deadbolts and locks are to beindependently keyed when turned from construction.

Note: lock supplier to send master keys directly to owner. Do not send to job.

NOTE: Units front doors shall be operable from the inside without the use of a key or anyspecial knowledge or effort.

NOTE: All windows should be double-pane insulating, low-e windows. All exterior doors shouldbe insulated.

NOTE: See specifications for interior and exterior finishes.

NOTE: See sheet A1.3-A1.6 for accessibility guidelines.

NOTE: Accessible and public common use areas require that door surfaces within 10" of thefloor be a smooth surface on the push side. (Including residential entry doors).

NOTE: The unlatching of any leaf shall not require more than one operationexcept as provided in Section 1008.1.9.5.

NOTE: Smoke doors on elevators are self closing and hold opens mag locks with 180° hingesconnected to fire alarm system.

HARDWARE NOTES:

1) ALL HARDWARE SHALL COMPLY WITH UFAS, (UNIFORM FEDERAL ACCESSIBLESTANDARDS) UNLESS SPECIFIED OTHERWISE.

2) HARDWARE FOR LABELED FIRE DOORS AND EXIT DOORS: CONFORM TOREQUIREMENTS OF NFPA 80 FOR LABELED FIRE DOORS AND TO NFPA 101 FOR EXITDOORS, AS WELL AS TO OTHER REQUIREMENTS SPECIFIED. PROVIDE HARDWARE LISTBY UL.

3) SEE SPECIFICATIONS FOR DOOR HARDWARE

4) TEMPERED GLASS PER IBC SECTION 2406.4.2 & 2406.4.3

5) INTERIOR CLUB PRIVACY LOCK-SETS MUST BE PUSH-BUTTON TYPE.

DEFINITIONSCRS - COLD ROLLED STEELC SERIES - INTERNALLY REINFORCED WITH STEEL HAT CHANNEL AND VOIDS FILLEDWITH FIBERGLASS INSULATION

UNIT HARDWARE SCHEDULE

HARWARE SET #1 (UNIT ENTRY)3 - SPRING HINGE1 - U.L. KEYLESS DEADBOLT1 - U.L. SGL. CYL. DEADBOLT1 - U.L. LEVER PASSAGE1 - KNOCKER/VIEWER1 - U.L. DOOR VIEWER1 - H.D. FLEX DOOR STOP1 - THRESHOLD1 - WEATHERSTRIPPING

HARDWARE SET #2 (UNIT PATIO)3 - HINGE1 - KEYLESS DEADBOLT1 - SGL. CYL. DEADBOLT1 - LEVER PASSAGE1 - H.D. FLEX DOOR STOP1 - THRESHOLD1 - WEATHERSTRIPPING

HARDWARE SET #3 (EXT.STORAGE)3 - HINGE1 - U.L. LEVER KEYLOCK1 - SPRING CRASH WIND CHAIN1 - THRESHOLD1 - WEATHERSTRIPPING

HARDWARE SET #4 (INT MECH)3 - HINGE1 - LEVER KEYLOCK1 - H.D. FLEX DOOR STOP

HARDWARE SET #5 (BED/BATH)3 - HINGE1 - LEVER PRIVACY1 - H.D. FLEX DOOR STOP

HARDWARE SET #6 (CLOSET)3 - HINGE1 - LEVER PASSAGE1 - H.D. FLEX DOOR STOP

HARDWARE SET #7 (CLOSETDOUBLE DOOR)3 - HINGE2 - LEVER DUMMY2 - H.D. FLEX DOOR STOP

COMMON HARDWARE SCHEDULE

HARWARE SET #8 (CLUB RR)4 - BALL BEARING HINGES1 - LEVER PRIVACY1 - PUSH/PULL PLATE1 - DOOR CLOSER1 - CONCAVE WALL BUMPER1 - THRESHOLD1 - DOOR SWEEP

HARDWARE SET #9(STORAGE/KEYTRACK)4 - BALL BEARING HINGES1 - SGL. CYL. DEADBOLT1 - LEVER PASSAGE

HARDWARE SET #10 (A/C CLOSET)4 - BALL BEARING HINGES1 - SGL. CYL. DEADBOLT1 - LEVER PASSAGE

HARDWARE SET #11 (STAIR/CORRIDOR)3 - BALL BEARING HINGES1 - FIRE RATED RIM PANIC DEVICE1 - PANIC DEVICE TRIM-PASSAGE FUNCTION1 - DOOR CLOSER - FULL COVER1 - CONCAVE WALL STOP1 - THRESHOLD1 - DOOR SWEEP1 - SMOKE SEAL

HARDWARE SET #12 (CORRIDORSTORAGE)4 - BALL BEARING HINGES1 - STOREROOM LEVER1 - DOOR CLOSER1 - CONCAVE WALL STOP1 - THRESHOLD1 - DOOR SWEEP1 - SMOKE SEAL

HARDWARE SET #13 (FIRE DOORS)8 - BALL BEARING HINGES2 - FIRE RATED VERTICAL PANIC DEVICE2 - PANIC DEVICE TRIM-PASSAGE FUNCTION2 - DOOR CLOSER2 - ELECTRO-MAG HOLD OPENS2 - THRESHOLD2 - DOOR SWEEPS2 - SMOKE SEAL

T

NOTE: Install electronic keyless entry in all unit entry doors & use HID chip for all building access andamenity areas, both programmable and readable by KABA system.

NOTE: Undercut all doors 1" for return air balance system. Reference MEP.

NOTE: Provide 3% transparency window shades in living areas and 1% shades in bedrooms.

1 2

3

4

5

6 8 9 10

11

12

13 14 15 16 17

18 19 23 26 27 28

29

30

T

T T T T

3' -

8"

2' -

0"

0' -

10

"

1' - 1"0' - 10"

1' - 1"

20

24

FIRESAFETYGLAZING

EMERGENCYEGRESS

32

7

33 34 35

A B C D E F

T T

T TTT

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

8/

31

/2

01

6 9

:41

:41

AM

A3.1

CWS

11/08/13

BAT

MEM

13-1926

DOOR & WINDOW SCHEDULE

WE

ST

5T

H S

TR

EE

T

13

01

W. 5

TH

ST

.A

U ST

IN, T

X 7

87

03

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

08/31/16

08/15/16

Door Schedule

Type Mark Description MaterialDoor Door

Fire Rating LocationWidth Height

1 FLUSH SINGLE SC 3' - 0" 8' - 0" 20 MIN. UNIT ENTRY

2 1 PANEL SINGLE 3' - 0" 8' - 0" n/a

3 1 PANEL SINGLE HC 2' - 10" 8' - 0" n/a UNIT

4 1 PANEL SINGLE HC 2' - 6" 8' - 0" n/a UNIT

5 1 PANEL SINGLE HC 2' - 0" 8' - 0" n/a UNIT

6 1 PANEL SINGLE LOUVERED HC 2' - 6" 8' - 0" n/a UNIT

7 1 PANEL SINGLE LOUVERED HC 2' - 10" 8' - 0" n/a UNIT

8 FLUSH SINGLE HC 2' - 10" 8' - 0" n/a UNIT

9 FLUSH SINGLE HC 3' - 0" 8' - 0" n/a UNIT

10 1 PANEL DOUBLE HC 5' - 0" 8' - 0" n/a UNIT

11 1 PANEL DOUBLE HC 4' - 0" 8' - 0" n/a UNIT

12 1 PANEL DOUBLE HC 3' - 0" 8' - 0" n/a UNIT

13 1 PANEL DOUBLE HC 5' - 0" 8' - 0" n/a UNIT

14 1 PANEL DOUBLE SLIDING HC 6' - 0" 8' - 0" n/a UNIT

15 CRS C SERIES FLUSH HM 3' - 0" 8' - 0" 3 hr. CORRIDOR

16 GLASS LITE SINGLE HM / TEMPERED 3' - 0" 8' - 0" n/a UNIT/CLUB

17 STOREFRONT SINGLE TEMPERED 3' - 0" 8' - 0" n/a CLUB

18 GLASS LITE DOUBLE SLIDING HM / TEMPERED 6' - 0" 8' - 0" n/a UNIT

19 GLASS LITE SINGLE W/SIDELIGHT HM / TEMPERED 6' - 0" 8' - 0" n/a CLUB

23 STOREFRONT DOUBLE TEMPERED 5' - 0" 8' - 0" n/a CLUB

24 STOREFRONT DOUBLE SLIDING TEMPERED 6' - 0" 8' - 0" n/a CLUB

26 FLUSH SINGLE HM 3' - 0" 6' - 8" 20 min. GARAGE / 1ST FLOOR

27 FLUSH SINGLE HM 3' - 0" 8' - 0" n/a GARAGE / 1ST FLOOR

28 FLUSH SINGLE VISION HM 3' - 0" 8' - 0" 90 min. STAIR

29 FLUSH SINGLE VISION HM 3' - 0" 6' - 8" 90 min. STAIR

30 FLUSH DOUBLE HM 5' - 0" 8' - 0" n/a GARAGE / 1ST FLOOR

32 GARAGE HM 24' - 0" 11' - 3" n/a GARAGE / 1ST FLOOR

33 Accordian-Type Fire Doors HM 6' - 6 7/8" 8' - 6 1/2" 90 min. CLUB

34 ELEVATOR SMOKE DOOR HM 3' - 8" 8' - 0" 90 min. ELEVATOR

35 FLUSH SINGLE HM 3' - 0" 8' - 0" 90 min. TEMP. 2 HR FIRE WALL

Window Schedule

Type MarkR.O.

Type Material Finish Fire Rating Description LocationWidth Height

A 6' - 0" 6' - 0" Slider Aluminum Bronze n/a Double Pane Insulated Low E Unit

B 4' - 0" 6' - 0" Slider Aluminum Bronze n/a Double Pane Insulated Low E Unit

C 2' - 0" 8' - 0" Fixed Aluminum Bronze n/a Double Pane Insulated Low E Unit

D 6' - 0" 1' - 6" Fixed Aluminum Bronze n/a Double Pane Insulated Low E Unit

E 7' - 6" 1' - 6" Fixed Aluminum Bronze n/a Double Pane Insulated Low E Unit

F 6' - 0" 8' - 0" Fixed Aluminum Bronze n/a Double Pane Insulated Low E Unit

1

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 2: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

3' - 0" 5' - 0"

8' - 0"

3' -

0"

5' -

5"

S1

8' -

5"

M1 M2

S2

T

T

T

T

M1 M2

3' - 0" 3' - 0" 3' - 0" 6' - 2 1/2" 1' - 8 1/4"

16' - 10 3/4"

5' -

5"

3' -

0"

6' - 0" CLEAR

3' -

0"

5' -

5"

8' -

5"

S3

2' - 7 1/4"

M1

M2

S9

M1 M2

5' -

5"

3' -

0"

8' -

5"

EQ EQ

6' - 0"

5' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0"

17' - 0"

5' -

5"

3' -

0"

8' -

5"

S11

M1 M2

S4

M1 M2

EQ EQ EQ EQ

12' - 0"

5' -

5"

3' -

0"

8' -

5"

4' - 9" 5' - 0" 5' - 0" 1' - 0" 6' - 2 1/2" 1' - 0" 5' - 1 1/2" 5' - 1 1/2" 5' - 1 1/2" 5' - 1 1/2" 5' - 1 1/2" 5' - 1 1/2" 5' - 1 1/2" 5' - 1 1/2" 4' - 7" 4' - 7" 4' - 7" 4' - 7" 1' - 1 1/2" 3' - 2 1/2" 1' - 1"

3' -

0"

5' -

1 1

/2

"2

' - 5

"

10

' - 6

"

S5

T

T

T

T

87' - 8"

M1M2

T

T

T

T

T

T

8' -

0"

CL

EA

R

6' - 0" CLEAR

8' -

0"

CL

EA

R

3' - 0" CLEAR

T

T

T

T

3' - 6" 3' - 6" 3' - 6" 3' - 6" 5' - 2 1/2" 3' - 6" 3' - 6" 3' - 6" 3' - 3 1/2" 1' - 9" 2' - 9 1/2" 5' - 2 1/2" 2' - 9 1/2" 1' - 11"

3' -

0"

5' -

1 1

/4

"1

' - 1

0 3

/4

"

10

' - 0

"

S15

M1M2

T

5' - 0" CLEAR

T

T

T

T

T

5' - 0" CLEAR

8' -

0"

CL

EA

R

47' - 5 1/2"

8' -

0"

CL

EA

R

3' - 0" 3' - 0" 3' - 0"

9' - 0"

1' -

10

3/

4"

5' -

1 1

/4

"3

' - 0

"

10

' - 0

"

S16

M1 M2

0' - 11 1/2" 3' - 2 1/2" 0' - 11 1/2"

5' - 1 1/2"

3' -

0"

8' -

2 1

/2

"

S17

T T

T T

M1

S18

M1

5' - 1 1/2"

3' -

0"

5' -

5"

8' -

5"

2' - 6 3/4" 2' - 6 3/4"

MULLION SIZES

M1 - 2 1/2" X 5"

M2 - 5" X 5"

M3 - 2 1/2" X 10"

S6

5' - 5"5' - 0"5' - 0"5' - 0"5' - 0"5' - 0"5' - 0"5' - 5 3/4"

40' - 10 3/4"

2' -

4 3

/4

"5

' - 1

1/

4"

3' -

0"

10

' - 6

"

M1M2

S12

M1

M2

2' - 8 3/4"

3' -

0"

5' -

5"

8' -

5"

5' -

5"

3' -

0"

8' -

5"

3' - 0"

S19

M1

M2

S20

5' -

5"

3' -

0"

8' -

5"

T

T

M1 M2

T

T

5' - 0" 2' - 9 1/2" 6' - 4" 1' - 6"

15' - 7"

S21

M1 M2

3' - 6 1/4" 1' - 5 3/4" 3' - 6 1/2" 3' - 6 1/2" 3' - 6 1/2"

15' - 7 1/4"

3' -

0"

5' -

5"

8' -

5"

3' - 0" CLEAR

8' -

0"

CL

EA

R

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

8/

31

/2

01

6 9

:41

:42

AM

A3.1A

CWS

03/23/16

BAT

MEM

13-1926

STOREFRONT ELEVATIONS

WE

ST

5T

H S

TR

EE

T

13

01

W. 5

TH

ST

.A

U ST

IN, T

X 7

87

03

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

08/31/16

08/15/16

1

1

1

1 1

1 1

No. Revision Date

1 REV 1 Date 1

Page 3: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

S28

M1 M2

1' -

10

3/

4"

5' -

1 1

/4

"3

' - 0

"

10

' - 0

"

1' - 11 1/2" 5' - 2 1/2" 3' - 2 3/4" 3' - 10"

14' - 2 3/4"

T

T

T

T

T

5' - 0" CLEAR

8' -

0"

CL

EA

R

MULLION SIZES

M1 - 2 1/2" X 5"

M2 - 5" X 5"

M3 - 2 1/2" X 10"

S23

M1 M2

3' - 0"3' - 0"3' - 0"3' - 6 1/4"

12' - 6 1/4"

5' -

5"

3' -

0"

8' -

5"

S29

M1

EQ EQ EQ

11' - 6"

6' -

6"

3' -

0"

9' -

6"

S30

M1M2

4' - 3 1/2"4' - 8 1/2"

9' - 0"

6' -

6"

3' -

0"

9' -

6"

3' - 0" CLEAR

8' -

0"

CL

EA

R

1' - 2 3/4" 3' - 2 1/2" 1' - 2 3/4"

5' - 8"

1' -

4 3

/4

"5

' - 1

1/

4"

3' -

0"

9' -

6"

T

T

T

T

T

S31

M1 M2

6' -

6"

3' -

0"

9' -

6"

EQEQ

6' - 8 3/4"

S32

M2 M1

EQEQ

6' - 9 1/2"

6' -

6"

3' -

0"

9' -

6"

S33

M2 M1

1' - 9 1/2"5' - 2 1/2"1' - 9 1/2"

8' - 9 3/4"

5' - 0" CLEAR

8' -

0"

CL

EA

R

1' -

4 3

/4

"5

' - 1

1/

4"

3' -

0"

9' -

6"

T

T

T

T

T

S34

M1 M2

S25

M1 M2

EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ

45' - 0 3/4"

5' -

5"

3' -

0"

8' -

5"

3' - 0" CLEAR

8' -

0"

CL

EA

R

1' - 7 1/2" 3' - 2 1/2" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0"

22' - 10"

5' -

5"

3' -

0"

8' -

5"

S35

M1M2

S24

M1 M2

3' - 0 1/2" 3' - 0 1/2" 3' - 2 1/4" 3' - 4 3/4"

12' - 8"

5' -

2 1

/2

"3

' - 0

"

8' -

2 1

/2

"

3' - 0"3' - 0"3' - 0"3' - 6 1/4"

12' - 6 1/4"

5' -

5"

3' -

0"

8' -

5"

3' - 0" CLEAR

8' -

0"

CL

EA

R

S22

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

8/

31

/2

01

6 9

:41

:43

AM

A3.1B

CWS

03/23/16

BAT

MEM

13-1926

STOREFRONT ELEVATIONS

WE

ST

5T

H S

TR

EE

T

13

01

W. 5

TH

ST

.A

U ST

IN, T

X 7

87

03

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

08/31/16

08/15/16

111111

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 4: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

4' - 11" 18' - 4 1/2" 4' - 11"

C2

TT T

T

28' - 2"

9' -

2 1

/2

"3

' - 8

"

12

' - 1

0 1

/2

"

C1

T T

T

11' - 8 3/4" 5' - 2 1/2" 11' - 8 3/4"

28' - 8"

3' -

5 3

/4

"8

' - 0

"2

' - 3

1/

2"

5' -

1 1

/4

"3

' - 0

"

21

' - 1

0 1

/2

"

8' -

0"

CL

EA

R

5' - 0" CLEAR

M3

T T

MULLION SIZES

M1 - 2 1/2" X 5"

M2 - 5" X 5"

M3 - 2 1/2" X 10"

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

8/

31

/2

01

6 9

:41

:43

AM

A3.1C

CWS

03/23/16

BAT

MEM

13-1926

CURTAINWALL ELEVATIONS

WE

ST

5T

H S

TR

EE

T

13

01

W. 5

TH

ST

.A

U ST

IN, T

X 7

87

03

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

08/31/16

08/15/16

1

No. Revision Date

1 REV 1 Date 1

Page 5: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

DW

REF

.

DW

REF

.

LIVING/KITCHEN

BEDROOM

WIC

BATH

BALCONY

UTIL.

A/C& WH

36"X60"TUB SHOWER

9

6

7

8

8

3

11R1S

2R

2S

/A3.5 4

/A

3.5

3

/A

3.5

8/

A3

.59

/A3.5 7 /A

3.5

6

/A3.5 5

4' - 1"

1' - 6 1/2"

1' - 4 1/2"

1' - 4" 1' - 6 1/2"

3' - 6" 1' - 10 1/2"

18' - 7 1/2"

4' -

2"

2' -

2"

10

' - 9

1/

2"

12

' - 1

0 1

/2

"

32

' - 1

0"

7' - 2"1' - 11 1/2"

3' - 7"3' - 5 1/2"1' - 10"

1' -

2 1

/2

"5

' - 2

"

1' -

5 1

/2

"

2' -

1 1

/2

"

1' -

8 1

/2

"

2' -

2"

1' -

6 1

/2

"

1' -

9 1

/2

"

3' - 10" 2' - 3" 5' - 0" 3' - 9"

SL

OP

E

1/

4"=

1'-

0"

3" SOLID BLOCKINGAT END OF EACHRAIL(TYP)

42" GUARDRAIL(TYP)48" GUARDRAIL ATCOURTYARD LEVEL 2

A

16

D ABOVE

LIVING/KITCHEN

BEDROOM

WIC

BATH

BALCONY

UTIL.

C

VP

C VP

T

C

TC 8'-6"A.F.F.

8'-0"A.F.F.

3324

3042

3024

3642

24" CAB. 30" CAB.

3 1/2"FILLER

MICROWAVE/VENTHOODCOMBO

3" FILLER

3 1/2"FILLER

30" OPENFOR RANGE

33" OPENFOR REF.

12' - 4 3/4" R.O.

0' -

3"

3' -

6"

1' -

6"

3' -

0"

8' -

0"

TILE BULLNOSE

FURROUT

3642

36" CAB.

3" FILLER

24" OPENFOR D.W.

3" FILLER

14' - 9"

18' - 0 1/2"

0' -

3"

3' -

6"

1' -

6"

3' -

0"

8' -

0"

TILE BULLNOSE

FURROUTOPEN SHELVING

TUB/SHOWER

3' - 0 3/4"

8' - 10 1/4"

1' -

11

"0

' - 8

"1

' - 3

"1

' - 3

"

5' -

1"

1

TOWEL HOOK@ 4'-6" A.F.F.

SHOWER HEAD@ 7'-0" A.F.F.

FURROUT

1

TUB/SHOWER

5' - 1 1/4"

5' - 7 1/4"

1' -

3"0

' - 6

" 1' -

5"

5' -

4"

8' -

6"

FURROUT

1 1

3

MIRROR

4" BACKSPLASH

33" VB 1 1/2" FILLER

1' - 6 1/2" 1' - 4" 2' - 11 1/4"

8' - 10 1/4"

TUB/SHOWER

5' -

4"

0' -

8"

1' -

3"

1' -

3"

8' -

6"

0' -

11

"1

' - 0

"2

' - 7

"

4' -

2"

2' -

10

"

7' -

0"

2430

FURROUT

3' - 5 1/4"7' - 5 3/4"

15' - 11 1/4"

A/C CLOSETUTIL.

RETURN AIR VENT

UNDERCUT DOOR 1"

1"X34" = 34 SQ.IN. FREE AREA

24"X83" = 1992 SQ.IN. FREE AREA

FREE AREA REQUIREMENTS

TOTAL FREE AREA REQUIRED = 100 SQ.IN.TOTAL FREE AREA PROVIDED = 2026 SQ.IN.

FLOOR FINISHES

VP - VINYL PLANK

C - CARPET

T - TILE

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:41

:45

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.5

UNIT A1 FLOOR PLANS & INT.ELEVATIONS

08/31/16

08/15/16

1/4" = 1'-0"1 UNIT A1 FLOOR PLAN 1/4" = 1'-0"2 UNIT A1 FINISH FLOOR PLAN

3/8" = 1'-0"3 UNIT A1 - KITCHEN ELEVATION 1 3/8" = 1'-0"4 UNIT A1 - KITCHEN ELEVATION 2

3/8" = 1'-0"5 UNIT A1 - BATH ELEVATION 1 3/8" = 1'-0"6 UNIT A1 - BATH ELEVATION 2

3/8" = 1'-0"7 UNIT A1 - BATH ELEVATION 3 3/8" = 1'-0"8 UNIT A1 - UTILITY ELEVATION

3/8" = 1'-0"9

UNIT A1 - A/C CLOSET & MAKE UP AIRCALC. ELEVATION

11

1

1

1

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 6: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

REF

.

DW

REF

.

DW

LIVING/KITCHEN

BEDROOM

UTIL.

BATH

WIC

BALCONY

9

6

7

8

1

8

3

2R

2S

1R1S

36"X60"TUB/

SHOWER

A/C& WH

/A

3.5

A3

/A3.5A 4

/A

3.5

A8

/A

3.5

A9

/A3.5A 7

/A3.5A 5

/A

3.5

A6

S9

4' - 1" 1' - 6 1/2"

1' - 4 1/2" 1' - 4"

1' - 6 1/2" 3' - 6" 1' - 10 1/2"

18' - 7 1/2"

4' -

2"

2' -

2"

10

' - 9

1/

2"

11

' - 9

1/

2"

31

' - 9

"

1' -

2 1

/2

"5

' - 2

" 1' -

5 1

/2

"

2' -

0 1

/2

"

1' -

9 1

/2

"

2' -

2"

1' -

6 1

/2

"

1' -

9 1

/2

"1

3' -

9 1

/2

"

3' - 8"3' - 5 1/2"1' - 10"

1' - 11 1/2" 7' - 2"

5' - 11 1/2" 2' - 11"

0' - 5 1/2"

SL

OP

E

1/

4"=

1'-

0"

3" SOLID BLOCKINGAT END OF EACHRAIL(TYP)

42' GUARDRAIL(TYP)

D ABOVE

16

LIVING/KITCHEN

BEDROOM

UTIL.

BATH

WIC

BALCONY

C

VPC VP

C

T

C T

8'-6"A.F.F.

8'-0"A.F.F.

3324

1842

3024

3642

24" CAB. 18" CAB.30" OPENFOR RANGE

33" OPENFOR REF

TILE BULLNOSE

3 1/2" FILLER MICROWAVE/VENTHOODCOMBO

2" FILLER

3 1/2"FILLER

0' -

3"

3' -

6"

1' -

6"

3' -

0"

8' -

0"

11' - 3 3/4" R.O.

FURROUT

3642

36" CAB.

TILE BULLNOSE

3"FILLER24" OPENFOR D.W.

14' - 8"

18' - 0 1/2"

0' -

3"

3' -

6"

1' -

6"

3' -

0"

8' -

0"

FURROUTOPEN SHELVING 3" FILLER

TUB/SHOWER

3' - 0 3/4"

8' - 10 1/4"

1' -

11

"0

' - 8

"

1' -

3"

1' -

3"

5' -

1"

1

SHOWER HEAD@ 7'-0" A.F.F.

FURROUTTOWEL HOOK@ 4'-6" A.F.F.

1

TUB/SHOWER

5' - 1 1/4"

5' - 7 1/4"

1' -

3" 0

' - 6

"1' -

5"

5' -

4"

8' -

6"

FURROUT

1 1

33" VB

MIRROR

4" BACK-SPLASH

TUB/SHOWER

3' - 0 3/4" 1' - 6 1/2" 1' - 4"

1' -

3"

1' -

3"

0' -

8"

5' -

4"

8' -

6"

2' -

7"

1' -

0"

0' -

11

"

4' -

2"

2' -

10

"

7' -

0"

8' - 10 1/4"

1 1/2"FILLER

3

FURROUT

2430

WASHER/DRYER

3' - 6 1/4"

A/C CLOSETUTIL.

RETURN AIR VENT

UNDERCUT DOOR 1"

1"X34" = 34 SQ.IN. FREE AREA

24"X83" = 1992 SQ.IN. FREE AREA

FREE AREA REQUIREMENTS

TOTAL FREE AREA REQUIRED = 100 SQ.IN.TOTAL FREE AREA PROVIDED = 2026 SQ.IN.

7' - 6 3/4"

16' - 0"

FLOOR FINISHES

VP - VINYL PLANK

C - CARPET

T - TILE

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:41

:46

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.5A

UNIT A1-A FLOOR PLANS &INT. ELEVATIONS

08/31/16

08/15/16

1/4" = 1'-0"1 UNIT A1-A FLOOR PLAN 1/4" = 1'-0"2 UNIT A1-A FINISH FLOOR PLAN

3/8" = 1'-0"3 UNIT A1-A - KITCHEN ELEVATION 1 3/8" = 1'-0"4 UNIT A1-A - KITCHEN ELEVATION 2

3/8" = 1'-0"5 UNIT A1-A - BATH ELEVATION 1 3/8" = 1'-0"6 UNIT A1-A - BATH ELEVATION 2

3/8" = 1'-0"7 UNIT A1-A - BATH ELEVATION 3 3/8" = 1'-0"8 UNIT A1-A - UTILITY ELEVATION

3/8" = 1'-0"9

UNIT A1-A - A/C CLOSET & MAKE UP AIRCALC. ELEVATION

11

1

1

1

1

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 7: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

REF

.

DW

REF

.

DW

LIVING/KITCHEN

BEDROOMUTIL.

BATH

WIC

BALCONY

/A

3.5

B3

/A3.5B 4

AC& WH

2R

2S

1R1S

36"X60"TUB/

SHOWER

A

/A

3.5

B8

/A

3.5

B9

/A3.5B 5

/A

3.5

B6

/A3.5B 7

8

3

8

1

7

6

9

WALL TYPEVARIES PER UNIT

LOCATION

1' - 10 1/2"3' - 6"1' - 6 1/2"

1' - 4"1' - 4 1/2"

2' - 9 1/2"4' - 4"0' - 5 1/2"

20' - 7" (20' - 5" @ TENANT SEPARATION WALL LOCATIONS)

6' -

4 1

/2

"1

0' -

9 1

/2

"1

0' -

2 1

/2

"

30

' - 2

"

5' - 8 1/2"2' - 3"3' - 0"4' - 1"

1' -

8 1

/2

"4

' - 8

"1

' - 5

1/

2"

1' -

10

"

2' -

0"

2' -

2"

1' -

6 1

/2

"

1' -

9 1

/2

"

3' - 7 1/2"3' - 5 1/2"1' - 10"

SL

OP

E

1/

4"=

1'-

0"

3" SOLID BLOCKINGAT END OF EACHRAIL(TYP)

42" GUARDRAIL(TYP)48" GURARDRAIL ATCOURTYARD LEVEL 2

ALTERNATE WALLCONDITION SHOWN

(OCCURS ON FLOORS5-6 @ CORRIDOR).

TYP. WALL IS TENANTSEP. UNIT INTERIOR

DIMENSION REMAINSTHE SAME.

16C

E ABOVE

LIVING/KITCHEN

BEDROOM

UTIL.

BATH

WIC

BALCONY

C

VP

C VP

C

T

C T 8'-6"A.F.F.

8'-0"A.F.F.

3324

1242

3024

2442

12" CAB. 12" CAB.

1 1/2" FILLERMICROWAVE/VENTHOODCOMBO

3" FILLER

3" FILLER 30" OPENFOR RANGE

33" OPENFOR REF.

TILE BULLNOSE

9' - 8 3/4"

0' -

3"

3' -

6"

1' -

6"

3' -

0"

8' -

0"

FURROUT

2442 3342

21" CAB.36" CAB. 3" FILLER

WALL TYPEVARIES PERUNIT LOCATION

TILE BULLNOSE

16' - 4 1/2"

0' -

3"

3' -

6"

1' -

6"

3' -

0"

8' -

0"

19' - 10"

3" FILLEROPEN SHELVING FURROUT

1

SHOWER HEAD@ 7'-0" A.F.F.

TUB/SHOWER

3' - 0 3/4"

10' - 1 1/4"

1' -

3"

1' -

3"0

' - 8

" 1' -

11

"3

' - 5

"

8' -

6"

FURROUT

24" TB @4'-6" A.F.F.

5' - 1 1/4"

5' - 7 1/4"

5' -

4"

1' -

5"

0' -

6"

1' -

3"

8' -

6"

1

TUB/SHOWER

FURROUT

33" VB 15" DB

1

3

1

MIRROR2430

4" BACKSPLASH

3' - 0 3/4" 1' - 6 1/2" 1' - 4"

1 1/2"FILLER

10' - 1 1/4"

5' -

4"

0' -

8"

1' -

3"

1' -

3"

8' -

6"

2' -

2"

1' -

0"

2' -

7"

4' -

2"

2' -

10

"

7' -

0"

FURROUT

TUB/SHOWERWASHER/DRYER

3' - 5 1/4"

A/C CLOSETUTIL.

RETURN AIR VENT

UNDERCUT DOOR 1"

1"X34" = 34 SQ.IN. FREE AREA

24"X83" = 1992 SQ.IN. FREE AREA

FREE AREA REQUIREMENTS

TOTAL FREE AREA REQUIRED = 100 SQ.IN.TOTAL FREE AREA PROVIDED = 2026 SQ.IN.

7' - 6 3/4"

15' - 5 1/4"

FLOOR FINISHES

VP - VINYL PLANK

C - CARPET

T - TILE

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:41

:47

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.5B

UNIT A1-B FLOOR PLANS &INT. ELEVATIONS

08/31/16

08/15/16

1/4" = 1'-0"1 UNIT A1-B FLOOR PLAN 1/4" = 1'-0"2 UNIT A1-B FINISH FLOOR PLAN

3/8" = 1'-0"3 UNIT A1-B - KITCHEN ELEVATION 1 3/8" = 1'-0"4 UNIT A1-B - KITCHEN ELEVATION 2

3/8" = 1'-0"5 UNIT A1-B - BATH ELEVATION 1 3/8" = 1'-0"6 UNIT A1-B - BATH ELEVATION 2

3/8" = 1'-0"7 UNIT A1-B - BATH ELEVATION 3 3/8" = 1'-0"8 UNIT A1-B - UTILITY ELEVATION

3/8" = 1'-0"9

UNIT A1-B - A/C CLOSET & MAKE UP AIRCALC.

11

11

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 8: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

REF.

DW

REF.

DW

BALCONY

KITCHEN

LIVING

UTIL.

BEDROOM

WIC

BATH

/A

3.6

4

/A3.63

/A3.65

/A

3.6

9/

A3

.61

0

16

9

6

7

5 8

8

3

1

/A3.66

/A

3.6

7

/A3.68

A/C& WH

1R1S

1R1S

2R

2S

36"X60"TUB/

SHOWER

12

' - 1

1"

10

' - 9

"2

' - 2

"

5' -

1"

5' -

6 1

/2

"3

0' -

0"

41

' - 1

1/

2"

3' - 4"

1' - 10 1/2"

3' - 6" 1' - 6 1/2"

1' - 4" 1' - 4 1/2"

1' - 10"

18' - 7 1/2"

3' -

3 1

/2

"2

' - 2

"

1' -

8 1

/2

"

2' -

7"

1' -

5 1

/2

"

1' -

9"

5' -

2"

1' -

2 1

/2

"

2' - 3"5' - 3"1' - 10"1' - 11"3' - 7"

3' - 7" 5' - 3 1/2" 1' - 10"

2' - 9 1/2" 3' - 0" 3' - 0" 2' - 6" 0' - 10"

SL

OP

E

1/

4"=

1'-

0"

3" SOLID BLOCKINGAT END OF EACHRAIL(TYP)

42" GUARDRAIL(TYP)

TR

C C

D ABOVE

BALCONY

KITCHEN

LIVING

UTIL.

BEDROOM

WICBATH

C

VP

CVP

T

C

T C8'-6"A.F.F.

8'-0"A.F.F.

TR

36" CAB. 2 1/2" FILLER

2 1/2" FILLER

7' - 0"

18' - 0 1/2"

3' -

3"

3' -

0"

TILE BULLNOSE

FURROUT

21" TRASH PULL

OPEN SHELVING

3642

3024

12423642

24" CAB.

4" FILLER 3" FILLER

4" FILLER 3" FILLER24" OPENFOR D.W.

30" OPENFOR RANGE

MICROWAVE/VENTHOOD COMBO

12' - 5 1/4" R.O.

0' -

3"

5' -

0"

3' -

0"

8' -

0"

TILE BACKSPLASH

FURROUT

15" CAB.

7' - 7 1/4" R.O. 7' - 1 3/4"

18' - 0 1/2"

3642

3618

24" CAB.

0' -

3"

3' -

6"

1' -

6"

3' -

0"

8' -

0"

36" OPENFOR REF.

3" FILLER

TILEBULLNOSE

3" FILLER

3" FILLERFURROUT

TUB/SHOWER

3' - 0 3/4"

8' - 10 1/4"

2' -

11

"1

' - 1

1"

0' -

8"

1' -

3"

1' -

3"

8' -

0"

1

SHOWER HEAD@ 7'-0" A.F.F.

FURROUT TOWEL HOOK@ 4'-6" A.F.F.

1

TUB/SHOWER

5' - 1 1/4"

5' - 7 1/4"

1' -

3"0

' - 6

" 1' -

5"

5' -

4"

8' -

6"

FURROUT

3

1 1

TUB/SHOWER33" VB

2430

MIRROR

1 1/2" FILLER

4" BACK-SPLASH

1' - 4" 1' - 6 1/2" 3' - 0 3/4"

8' - 10 1/4"

5' -

4"

0' -

8"

1' -

3"

1' -

3"

8' -

6"

0' -

11

"1

' - 0

"2

' - 7

"

4' -

2"

2' -

10

"

7' -

0"

FURROUT

WASHER/DRYER

3' - 5 1/4"

A/C CLOSET UTIL.

RETURN AIR VENT

UNDERCUT DOOR 1"

1"X34" = 34 SQ.IN. FREE AREA

24"X83" = 1992 SQ.IN. FREE AREA

3' - 2 3/4"9' - 9 1/4"

18' - 1 3/4"

FREE AREA REQUIREMENTS

TOTAL FREE AREA REQUIRED = 100 SQ.IN.TOTAL FREE AREA PROVIDED = 2026 SQ.IN.

FLOOR FINISHES

VP - VINYL PLANK

C - CARPET

T - TILE

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:41

:48

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.6

UNIT A2 FLOOR PLANS & INT.ELEVATIONS

08/31/16

08/15/16

1/4" = 1'-0"1 UNIT A2 FLOOR PLAN 1/4" = 1'-0"2 UNIT A2 FINISH FLOOR PLAN

3/8" = 1'-0"3 UNIT A2 - KITCHEN ELEVATION 1 3/8" = 1'-0"4 UNIT A2 - KITCHEN ELEVATION 2

3/8" = 1'-0"5 UNIT A2 - KITCHEN ELEVATION 3 3/8" = 1'-0"6 UNIT A2 - BATH ELEVATION 1

3/8" = 1'-0"7 UNIT A2 - BATH ELEVATION 2 3/8" = 1'-0"8 UNIT A2 - BATH ELEVATION 3

3/8" = 1'-0"9 UNIT A2 - UTILITY ELEVATION 3/8" = 1'-0"10

UNIT A2 - A/C CLOSET & MAKE UP AIRCALC. ELEVATION

11

1

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 9: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

REF.

DW

REF.

DW

BALCONY

BEDROOM

WIC

BATH

UTIL.KITCHEN

LIVING

PA

N.

1R

1S

1R

1S

2R2S

A/C& WH

36"x60"TUB/

SHOWER

LIN

EN

/A

3.7

3 /A

3.7

5

/A3.7 4

/A

3.7

9

/A3.7 11

/A

3.7

10

/A

3.7

8/A

3.7

6

/A3.7 7

SL

OP

E

1/

4"=

1'-

0"

3" SOLID BLOCKINGAT END OF EACHRAIL(TYP)

42" GAURDRAIL(TYP)

0' - 8"5' - 5"1' - 3"2' - 8"

2' - 0 1/2"

2' - 10 1/2"

22' - 4 1/2"

12

' - 7

1/

2"

14

' - 9

"

6' - 1"5' - 2"5' - 7 1/2"

3' -

6 1

/2

"5

' - 7

"2

' - 7

1/

2"

1' -

5"

1' -

6 1

/2

"

7' -

1"

3' -

8 1

/2

"3

' - 6

1/

2" 1

' - 8

"

1' -

7 1

/2

"

1' -

0"

1' -

9 1

/2

"2

' - 9

1/

2"

2' -

0"

1' -

8 1

/2

"

4' - 0"2' - 0 1/2"

2' - 9"

2' - 3"

1' - 10 1/2"

0' - 10"0' - 5 1/2"

2' - 1 1/2"

1' - 11"

30

' - 2

"

18

A

3 12

36

7

5

1

TR

BALCONY

BEDROOM

WIC

BATH

UTIL.

KITCHEN

LIVING

VP

C

VP T

8'-6"A.F.F.

8'-0"A.F.F.

TR

TILE BACKSPLASH

MICROWAVE/VENTHOOD COMBO3" FILLER

3" FILLER 30" OPENFOR RANGE

FURROUT

13' - 11 3/4" R.O.

1 1/2"FILLER

2742 3042 3342

30" PAN. FRONT30" CAB.15" CAB.

3' -

6"

1' -

6"

3' -

0"

8' -

0"

33" DB

1 1/2" FILLER 3" FILLER

3" FILLER

TILEBULLNOSE

36" OPENFOR REF.

ENTRYDOOR

FURROUT

3' -

6"

1' -

6"

3' -

0"

8' -

0"

6' - 8 3/4" R.O.0' - 3 1/2"

12' - 3 1/4"

3618

2742

15" CAB.24" OPENFOR D.W.

1" ENDPANEL

1" ENDPANEL

FURROUT

3' -

0"

36" CAB.

6' - 11" 3' - 10 1/4"

13' - 9 3/4"

2' -

0"

6' -

0" 8

' - 0

"

TUB/SHOWER

24" TB @4'-6" A.F.F.

SHOWER HEAD @ 7'-0" A.F.F.

18' -

6"

8' -

6"

FURROUT

3' - 0 3/4"

13' - 11 1/4"

1' -

11

"

0' -

8"

1' -

3"

1' -

3"

TUB/SHOWER

1

8' -

6"

FURROUT

5' - 1 1/4"

5' - 7 1/4"

5' -

4"

1' -

5"

0' -

6"

1' -

3"

8' -

6"

1 1/2"FILLER

4" BACKSPLASH

1 1

TUB/SHOWER

8' -

6"

8' -

6"

FURROUT

30" LIN. FRONT15" DB 33" VB 15" DB

4' -

2"

2' -

10

"

7' -

0"

1' -

0"

2' -

7"

5' -

4"

0' -

8"

1' -

3"

1' -

3"

1' - 5" 1' - 6 1/2" 3' - 0 3/4"

13' - 11 1/4"

MIRROR

WASHER/DRYER

3' - 5 1/4"

UTIL. 1"X34" = 34 SQ.IN. FREE AREA

24"X83" = 1992 SQ.IN. FREE AREA

UNDERCUT DOOR 1"

FREE AREA REQUIREMENTS

TOTAL FREE AREA REQUIRED = 100 SQ.IN.TOTAL FREE AREA PROVIDED = 2026 SQ.IN.

9' - 7"

A/C CLOSET

RETURN AIR VENT

UNDERCUT DOOR 1"

3' - 5 1/2"

FLOOR FINISHES

VP - VINYL PLANK

C - CARPET

T - TILE

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

TEMPORARY SHAFTLINER FOR PHASING

CORRIDOR WALL

0' - 10" 5' - 5" 1' - 3" 2' - 8" 2' - 0 1/2"BATH GREW 2"

CORRIDOR

ELEVATOR 2

BATH

WIC

BEDROOM

UTIL.

A/C& WH

1R

1S

2R2S

1R

1S

22' - 6 1/2"

E1 HR

W2 HRT

EM

P

BEDROOM

LIVING

WIC

BATH

(OPEN TO CORRIDOR BELOW)CORRIDOR

Q1HR

B1 HR

Q1HR

Q1HR

B1 HR

Q1HR

Q1HR

BREEZEBLOCKFEATURE WALL

CONT. 2X6 WALL.INTERIOR OF BEDROOM

2" SMALLER AS A RESULT.

AIR GAP

U1 HR

2' - 9"2' - 3"2' - 0 1/2"4' - 0"

EXTERIOR WALL

10' - 0"0' - 1"0' - 5 1/2"

0' - 5 1/2"

0' - 1"

0' - 11 1/2"

4' - 7"5' - 6 1/2"

0' - 1"

0' - 5 1/2"

0' -

10

"

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:41

:50

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.7

UNIT A3 FLOOR PLANS & INT.ELEVATIONS

08/31/16

08/15/16

1/4" = 1'-0"1 UNIT A3 FLOOR PLAN 1/4" = 1'-0"2 UNIT A3 FINISH FLOOR PLAN

3/8" = 1'-0"3 UNIT A3 - KITCHEN ELEVATION 1 3/8" = 1'-0"4 UNIT A3 - KITCHEN ELEVATION 2

3/8" = 1'-0"5 UNIT A3 - KITCHEN ELEVATION 3 3/8" = 1'-0"6 UNIT A3 - BATH ELEVATION 1

3/8" = 1'-0"7 UNIT A3 - BATH ELEVATION 2 3/8" = 1'-0"8 UNIT A3 - BATH ELEVATION 3

3/8" = 1'-0"9 UNIT A3 - UTILITY ELEVATION 3/8" = 1'-0"10

UNIT A3 - MAKE UP AIR CALC.ELEVATION

3/8" = 1'-0"11 UNIT A3 - A/C CLOSET ELEVATION

1/4" = 1'-0"1B

UNIT A3 FLOOR PLAN @ CORRIDORWALL

1/4" = 1'-0"1A UNIT A3 FLOOR PLAN @ EXTERIOR WALL

1

1 1

1

1

No. Revision Date

1 REV 1 Date 1

Page 10: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

REF.

DW

REF.

DW

BALCONY

LIVING

BEDROOM

WIC

BATH

KITCHEN UTIL.

5

1

7

63

123

A

/A

3.7

A3

/A

3.7

A5

/A3.7A4

/A3.7A11

/A

3.7

A9

/A

3.7

A1

0

/A

3.7

A8

/A

3.7

A6

/A3.7A7

PA

N.

LIN

EN

A/C& WH

36"X60"TUB/

SHOWER

1R

1S

1R

1S

2R2S

7' - 6" 2' - 10 1/2"

2' - 0 1/2"

2' - 11" 6' - 5"

22' - 4 1/2"

15

' - 5

1/

2"

14

' - 9

"

33

' - 0

"

2' - 9 1/2" 3' - 0" 3' - 0" 2' - 9 1/2" 5' - 3"

3' -

6 1

/2

"5

' - 1

"1

' - 4

1/

2"

1' -

5 1

/2

"

1' -

6 1

/2

"3

' - 6

"1

' - 8

1/

2"

2' - 5" 3' - 7" 2' - 1 1/2"

0' - 5 1/2" 0' - 10"

1' - 10 1/2"

2' - 3" 2' - 9" 2' - 0 1/2"

1' -

8"

1' -

4 1

/2

"

1' -

2 1

/2

"

1' -

9 1

/2

"2

' - 9

1/

2"

2' -

0"

1' -

8 1

/2

"

1' - 11"

SL

OP

E

1/

4"=

1'-

0"

3" SOLID BLOCKINGAT END OF EACHRAIL(TYP)

42" GUARDRAIL(TYP)48" GUARDRAIL ATCOURTYARD LEVEL 2

7' -

1"

4' -

8"

2' -

7"

TR

C16C

BALCONY

LIVING

BEDROOM

WIC

BATH

KITCHEN

UTIL.

VP

C

VP T

8'-6"A.F.F.

8'-0"A.F.F.

TR

30" PAN. FRONT

334230422742

15" CAB. 30" CAB.

TILE BACKSPLASH

30" OPENFOR RANGE

3" FILLER MICROWAVE/VENTHOOD COMBO

3" FILLER

3' -

6"

1' -

6"

3' -

0"

8' -

0"

FURROUT

1 1/2"FILLER

13' - 11 3/4" R.O.

30243618

2742

15" CAB.36" OPENFOR REF.

1 1/2" FILLER 3" FILLER

3" FILLERENTRYDOOR

6' - 8 3/4" R.O.0' - 3 1/2"

12' - 3 1/4"

3' -

0"

1' -

6"

3' -

6"

8' -

0"

FURROUT

21" TRASH 36" CAB. 24" OPENFOR D.W.

1" ENDPANEL

1" ENDPANEL

6' - 11" 3' - 10 1/4"

13' - 9 3/4"

3' -

0"

6' -

0"

2' -

0"

8' -

0"

TUB/SHOWER

24" TB @4'-6" A.F.F.

1

SHOWER HEAD @ 7'-0" A.F.F.

12' - 2 3/4"

3' -

5"

1' -

11

"

0' -

8"

1' -

3"

1' -

3"

8' -

6"

3' - 0 3/4"

FURROUT

TUB/SHOWER

1

1' -

3"0

' - 6

" 1' -

5"

5' -

4"

8' -

6"

FURROUT

33" VB15" DB24" LIN. FRONT

1 1

3

TUB/SHOWER

1 1/2"FILLER

MIRROR

4" BACK-SPLASH

1' - 5 1/2" 1' - 6 1/2" 3' - 0 3/4"

12' - 2 3/4"

1' -

0"

2' -

7"

0' -

8"

1' -

3"

1' -

3" 3

' - 2

"

4' -

2"

2' -

10

"

7' -

0"

FURROUT

3' - 5 1/4"

WASHER/DRYERUTIL. 1"X34" = 34 SQ.IN. FREE AREA

24"X83" = 1992 SQ.IN. FREE AREA

UNDERCUT DOOR 1"

9' - 7"

FREE AREA REQUIREMENTS

TOTAL FREE AREA REQUIRED = 100 SQ.IN.TOTAL FREE AREA PROVIDED = 2026 SQ.IN.

A/C CLOSET

RETURN AIR VENT

UNDERCUT DOOR 1"

3' - 5 1/2"

FLOOR FINISHES

VP - VINYL PLANK

C - CARPET

T - TILE

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:41

:52

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.7A

UNIT A3-A FLOOR PLANS &INT. ELEVATIONS

08/31/16

08/15/16

1/4" = 1'-0"1 UNIT A3-A FLOOR PLAN 1/4" = 1'-0"2 UNIT A3-A FINISH FLOOR PLAN

3/8" = 1'-0"3 UNIT A3-A - KITCHEN ELEVATION 1 3/8" = 1'-0"4 UNIT A3-A - KITCHEN ELEVATION 2

3/8" = 1'-0"5 UNIT A3-A - KITCHEN ELEVATION 3 3/8" = 1'-0"6 UNIT A3-A - BATH ELEVATION 1

3/8" = 1'-0"7 UNIT A3-A - BATH ELEVATION 2 3/8" = 1'-0"8 UNIT A3-A - BATH ELEVATION 3

3/8" = 1'-0"9 UNIT A3-A - UTILITY ELEVATION 3/8" = 1'-0"10

UNIT A3-A - MAKE UP AIR CALC.ELEVATION

3/8" = 1'-0"11 UNIT A3-A - A/C CLOSET ELEVATION

11

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 11: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

REF.

DW

REF.

DW

BALCONY

BEDROOM

LIVING

WIC

BATH

KITCHEN UTIL.

PA

N.

LIN

EN

1R

1S

2R2S

1R

1S

36"X60"TUB/

SHOWER

A/C& WH

A

123

36

7

5

1

/A

3.7

B3

/A

3.7

B5

/A3.7B 4

/A

3.7

B9

/A

3.7

B1

0

/A3.7B 11

/A

3.7

B8

/A

3.7

B6

/A3.7B 7

5' - 3"2' - 9 1/2"3' - 0"3' - 0"2' - 9 1/2"

15

' - 5

1/

2"

14

' - 9

"

33

' - 0

"

6' - 7"2' - 9"

2' - 0 1/2"

2' - 10 1/2"7' - 6"

22' - 4 1/2"

3' -

6 1

/2

"5

' - 7

"2

' - 7

1/

2"

1' -

5"

1' -

6 1

/2

"3

' - 6

"

2' - 0 1/2"2' - 9"2' - 3"

1' - 10 1/2"

0' - 10"0' - 5 1/2"

2' - 1 1/2"6' - 0"

7' -

1"

4' -

8"

2' -

7"

1' -

8"

1' -

4 1

/2

"

1' -

2 1

/2

"

1' -

9 1

/2

"2

' - 9

1/

2"

2' -

0"

1' -

8 1

/2

"

1' - 11"

SL

OP

E

1/

4"=

1'-

0" 3" SOLID BLOCKING

AT END OF EACHRAIL(TYP)

42" GUARDRAIL(TYP)48" GUARDRAIL ATCOURTYARD LEVEL 2

16 CC

BALCONY

BEDROOM

LIVING

WIC

BATH

KITCHEN

UTIL.

VP

C

VP T

8'-6"A.F.F.

8'-0"A.F.F.

MICROWAVE/VENTHOOD COMBO3" FILLER

3" FILLER

2742 3042

3024

3342

33" DB30" CAB.15" CAB. 30" PAN. FRONT30" OPENFOR RANGE

TILE BACKSPLASH

3' -

6"

1' -

6"

3' -

0"

8' -

0"

FURROUT

1 1/2"FILLER

14' - 0" R.O.

3618

2742

15" CAB.

3" FILLER1 1/2" FILLER

3" FILLER36" OPENFOR REF.

6' - 9"0' - 3 1/2"

12' - 3 1/2"

3' -

6"

1' -

6"

3' -

0"

8' -

0"

ENTRYDOOR

FURROUT

36" CAB.21" TRASH 24" OPENFOR D.W.

6' - 11" 3' - 10"

13' - 9 1/2"

1" ENDPANEL

1" ENDPANEL

3' -

0"

2' -

0"

6' -

0"

8' -

0"

FURROUTSHOWER HEAD @ 7'-0" A.F.F.

TUB/SHOWER

24" TB @4'-6" A.F.F.

13' - 11 1/2"

3' -

5"

1' -

11

"

0' -

8"

1' -

3"

1' -

3"

8' -

6"

1

3' - 0 3/4"

FURROUT

1

TUB/SHOWER

5' -

4"

1' -

5"

0' -

6"

1' -

3"

8' -

6"

5' - 1 1/4"

5' - 7 1/4"

FURROUT

MIRROR

30" LIN. FRONT 15" DB 33" VB 15" DB

1 1/2"FILLER

1 1

TUB/SHOWER

1' - 5" 1' - 6 1/2" 3' - 0 3/4"

13' - 11 1/4"

4' -

2"

2' -

10

"

7' -

0"

5' -

4"

0' -

8"

1' -

3"

1' -

3"

8' -

6"

1' -

0"

2' -

7"

4" BACKSPLASH

FURROUT

WASHER/DRYER

3' - 5 1/4"

UTIL. 1"X34" = 34 SQ.IN. FREE AREA

24"X83" = 1992 SQ.IN. FREE AREA

UNDERCUT DOOR 1"

9' - 7"

FREE AREA REQUIREMENTS

TOTAL FREE AREA REQUIRED = 100 SQ.IN.TOTAL FREE AREA PROVIDED = 2026 SQ.IN.

A/C CLOSET

RETURN AIR VENT

UNDERCUT DOOR 1"

FLOOR FINISHES

VP - VINYL PLANK

C - CARPET

T - TILE

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:41

:53

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.7B

UNIT A3-B FLOOR PLANS &INT. ELEVATIONS

08/31/16

08/15/16

1/4" = 1'-0"1 UNIT A3-B FLOOR PLAN 1/4" = 1'-0"2 UNIT A3-B FINISH FLOOR PLAN

3/8" = 1'-0"3 UNIT A3-B - KITCHEN ELEVATION 1 3/8" = 1'-0"4 UNIT A3-B - KITCHEN ELEVATION 2

3/8" = 1'-0"5 UNIT A3-B - KITCHEN ELEVATION 3 3/8" = 1'-0"6 UNIT A3-B - BATH ELEVATION 1

3/8" = 1'-0"7 UNIT A3-B - BATH ELEVATION 2 3/8" = 1'-0"8 UNIT A3-B - BATH ELEVATION 3

3/8" = 1'-0"9 UNIT A3-B - UTILITY ELEVATION 3/8" = 1'-0"10

UNIT A3-B - MAKE UP AIR CALC.ELEVATION

3/8" = 1'-0"11 UNIT A3-B - A/C CLOSET ELEVATION

11

1

11

1

No. Revision Date

1 REV 1 Date 1

Page 12: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

REF.

DW

REF.

DW

BALCONY

UTIL.

BEDROOM

WIC

BATH

LIVING KITCHEN

PA

N.

A/C& WH

1R1S

2R

2S

1R1S

36"X60"TUB/

SHOWER

18

9

6

7

8

1

8

3

/A

3.8

3

/A3.84

/A

3.8

9/

A3

.88

/A3.85

/A

3.8

6

/A3.87

CC

3' - 4" 1' - 10 1/2" 3' - 6" 1' - 6 1/2"

1' - 4"

1' - 4 1/2" 1' - 10"

18' - 6 1/2"

5' -

1"

18

' - 5

"1

0' -

9 1

/2

"6

' - 4

1/

2"

41

' - 1

1/

2"

1' -

9 1

/2

"1

' - 6

"

2' -

2"

1' -

8 1

/2

"

2' -

7"

1' -

5 1

/2

"

1' -

9"

5' -

2"

0' -

3"

0' -

11

1/

2"

3' - 10 1/2"

3' - 5 1/2"

1' - 6 1/2" 1' - 10"

0' - 1" 4' - 8 1/2" 4' - 6 1/2" 4' - 6 1/2"

18' - 7 1/2"

5

SL

OP

E

1/

4"=

1'-

0"

3" SOLID BLOCKINGAT END OF EACHRAIL(TYP)

42" GUARDRAIL(TYP)

/----

/--

--

/--

--

D ABOVE

BALCONY

LIVING

UTIL.

BEDROOM

WICBATH

KITCHEN

C

VP

CVP

C

T

CT8'-6"A.F.F.

8'-0"A.F.F.

30" PAN. FRONT

1842

3024

24421842 2742 1242

27" CAB.36" CAB.18" CAB.18" CAB. 30" OPENFOR RANGE

24"OPENFOR D.W.

3" FILLER

3"FILLERMICROWAVE/VENTHOOD COMBO4" FILLER

TILE BACKSPLASH

17' - 11 1/4" R.O.

0' -

3"

3' -

6"

1' -

6"

3' -

0"

8' -

0"

FURROUT

OPEN SHELVING

2" FILLER3" FILLER

3" FILLER 36" OPENFOR REF.

24" CAB.

3642

3618

7' - 6 1/4" R.O. 7' - 1 3/4"

17' - 11 3/4"

3' -

6"

1' -

6"

3' -

0"

8' -

0"

TILEBULLNOSE

FURROUT

TUB/SHOWER

3' - 0 3/4"

8' - 10 1/4"

3' -

5"

1' -

11

"

0' -

8"

1' -

3"

1' -

3"

8' -

6"

1

SHOWER HEAD @ 7'-0" A.F.F. FURROUT TOWEL HOOK@ 4'-6" A.F.F.

TUB/SHOWER

1' -

3"

0' -

6"

1' -

5"

5' -

4"

8' -

6"

5' - 1 1/4"

5' - 7 1/4"

1

FURROUT

2430

33" VB

MIRROR

1 1

TUB/SHOWER

4" BACK-SPLASH

1' - 4" 1' - 6 1/2" 3' - 0 3/4"

8' - 10 1/4"

4' -

2"

2' -

10

"

7' -

0"

2' -

2"

1' -

0"

2' -

7"

5' -

4"

0' -

8"

1' -

3"

1' -

3"

8' -

6"

FURROUT

WASHER/DRYER

3' - 5 1/4"

UTIL. 1"X30" = 34 SQ.IN. FREE AREA

24"X83" = 1992 SQ.IN. FREE AREA

A/C CLOSET

RETURN AIR VENT

UNDERCUT DOOR 1"

3' - 2 3/4"9' - 9 1/4"

18' - 1 3/4"

FREE AREA REQUIREMENTS

TOTAL FREE AREA REQUIRED = 100 SQ.IN.TOTAL FREE AREA PROVIDED = 2028 SQ.IN.

FLOOR FINISHES

VP - VINYL PLANK

C - CARPET

T - TILE

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:41

:54

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.8

UNIT A4 FLOOR PLANS & INT.ELEVATIONS

08/31/16

08/15/16

1/4" = 1'-0"1 UNIT A4 FLOOR PLAN 1/4" = 1'-0"2 UNIT A4 FINISH FLOOR PLAN

3/8" = 1'-0"3 UNIT A4 - KITCHEN ELEVATION 1 3/8" = 1'-0"4 UNIT A4 - KITCHEN ELEVATION 2

3/8" = 1'-0"5 UNIT A4 - BATH ELEVATION 1 3/8" = 1'-0"6 UNIT A4 - BATH ELEVATION 2

3/8" = 1'-0"7 UNIT A4 - BATH ELEVATION 3 3/8" = 1'-0"8 UNIT A4 - UTILITY ELEVATION

3/8" = 1'-0"9

UNIT A4 - A/C CLOSET & MAKE UP AIRCALC. ELEVATION

1

1

11

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 13: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

REF

.

DW

REF

.

DW

BALCONY

LIVING

BEDROOM

WIC

BATH

KITCHEN

UTIL.

PAN.1R1S

1R

1S

2R2S

LIN

EN

36"X60"TUB/

SHOWER

A/C& WH

A

12

3

36

7

1

5

/A

3.9

3

/A

3.9

5

/A3.9 4

/A

3.9

9/

A3

.91

0

/A3.9 11

/A

3.9

8

/A

3.9

6

/A3.9 7

5' - 5"3' - 11"2' - 0"2' - 10 1/2"

1' - 8 1/2"

1' - 3"7' - 4"

25' - 1 1/2"

13

' - 4

1/

2"

14

' - 0

"

5' - 8 1/2"3' - 11 1/2"5' - 0"4' - 11"

4' -

10

1/

2"

5' -

1"

1' -

4 1

/2

"1

' - 4

"

1' -

6 1

/2

"3

' - 6

"

7' -

1"

4' -

3"

2' -

9"

1' - 6 1/2"

0' - 6"

2' - 3"2' - 3"3' - 9"

0' - 10"0' - 5 1/2"

2' - 1 1/2"4' - 5 1/2"2' - 5"

2' -

0"

3' -

1"

2' -

3"

2' -

0 1

/2

"

1' -

2 1

/2

"

1' - 11"

SL

OP

E

1/

4"=

1'-

0"

3" SOLID BLOCKINGAT END OF EACHRAIL(TYP)

42" GUARDRAIL(TYP)48" GUARDRAIL ATCOURTYARD LEVEL 2

TR

A 16

30

' - 2

"

BALCONY

LIVING

BEDROOM

WIC

BATH

KITCHEN

UTIL.

VP

C

VP T

8'-6"A.F.F.

8'-0"A.F.F.

TR

TILE BULLNOSE

3" FILLER

3" FILLER MICROWAVE/VENTHOOD COMBO 1 1/2" FILLER

2742 3042

3024

1842

3618

15" CAB. 18" CAB.

13' - 2 3/4" R.O.

13' - 6 1/4"

3' -

6"

1' -

6"

3' -

0"

8' -

0"

FURROUT

30" DB 30" OPENFOR RANGE

TILEBACKSPLASH

3" FILLER

3" FILLER

3042

18" CAB.33" PAN. FRONT

3' - 0 3/4" 6' - 8 3/4" R.O.

15' - 0 1/4"

ENTRYDOOR

3' -

6"

1' -

6"

3' -

0"

8' -

0"

FURROUT1 1/2" FILLER

36" CAB.21" TRASH 24" OPENFOR D.W.

0' - 1" 0' - 1" 6' - 9" 0' - 1" 0' - 1" 4' - 2 3/4"

13' - 7 1/4"

1" ENDPANEL

1" ENDPANEL

3' -

0"

8' -

0"

FURROUTSHOWER HEAD @ 7'-0" A.F.F.

24" TB @4'-6" A.F.F.

1

TUB/SHOWER

3' - 0 3/4"

12' - 1 1/4"

3' -

5"

1' -

11

"

0' -

8"

1' -

3"

1' -

3"

8' -

6"

FURROUT

TUB/SHOWER

5' - 1 1/4"

5' - 7 1/4"

5' -

4"

1' -

5"

0' -

6"

1' -

3"

8' -

6"

1

FURROUT

11

33" VB15" DB24" LIN. FRONT

MIRROR

TUB/SHOWER

4" BACK-SPLASH

1 1/2" FILLER

1' - 4" 1' - 6 1/2" 3' - 0 3/4"

12' - 1 1/4"

5' -

4"

0' -

8"

1' -

3"

1' -

3"

8' -

6"

1' -

0"

2' -

7"

4' -

2"

2' -

10

"

7' -

0"

FURROUT

WASHER/DRYER

4' - 7 1/4"

UTIL. 1"X34" = 34 SQ.IN.FREE AREA

24"X83" = 1992 SQ.IN.FREE AREA

UNDERCUT DOOR 1"

7' - 4 1/2"

FREE AREA REQUIREMENTS

TOTAL FREE AREA REQUIRED = 100 SQ.IN.TOTAL FREE AREA PROVIDED = 2028 SQ.IN.

A/C CLOSET

RETURN AIR VENT

UNDERCUT DOOR 1"

3' - 5 1/2"

FLOOR FINISHES

VP - VINYL PLANK

C - CARPET

T - TILE

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:41

:56

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.9

UNIT A5 FLOOR PLANS & INT.ELEVATIONS

08/31/16

08/15/16

1/4" = 1'-0"1 UNIT A5 FLOOR PLAN 1/4" = 1'-0"2 UNIT A5 FINISH FLOOR PLAN

3/8" = 1'-0"3 UNIT A5 - KITCHEN ELEVATION 1 3/8" = 1'-0"4 UNIT A5 - KITCHEN ELEVATION 2

3/8" = 1'-0"5 UNIT A5 - KITCHEN ELEVATION 3 3/8" = 1'-0"6 UNIT A5 - BATH ELEVATION 1

3/8" = 1'-0"7 UNIT A5 - BATH ELEVATION 2 3/8" = 1'-0"8 UNIT A5 - BATH ELEVATION 3

3/8" = 1'-0"9 UNIT A5 - UTILITY ELEVATION 3/8" = 1'-0"10

UNIT A5 - MAKE UP AIR CALC.ELEVATION

3/8" = 1'-0"11 UNIT A5 - A/C CLOSET ELEVATION

1

1

1

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 14: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

REF

.D

W

REF

.D

W

BALCONY

LIVING

BEDROOM

WIC

BATH

UTIL.

KITCHEN

DINING

1R

1S

2R2S

42"X60"TUB/

SHOWER

LINEN

A/C& WH

PA

NT

RY

DE

SK

1R

1S

A

3

3

7

6

5

1

/A3.10 6

/A

3.1

07 /A3.10 8

/A

3.1

09

/A

3.1

03

/A

3.1

05

/A3.10 4

14

' - 1

1"

9' -

7 1

/2

"1

8' -

0"

1' -

2 1

/2

"1

' - 5

"4

' - 0

"1

' - 4

1/

2"

1' -

8"

7' -

2"

23

' - 8

1/

2"

2' -

2"

1' -

8"

1' -

11

1/

2"

1' -

9"

2' -

0 1

/2

"

0' -

5"

0' -

11

1/

2"

5' -

5"

43

' - 3

1/

2"

14' - 8" 1' - 11 1/2" 5' - 8" 2' - 11"

27' - 6 1/2"

7' - 9 1/2" 7' - 5"

0' - 5 1/2"

2' - 6 1/2" 4' - 6 1/2"

1' -

11

1/

2"

2' -

3"

3' -

5 1

/2

"

3' - 4"

1' - 6 1/2"

1' - 5"

1' - 3"

5' - 3" 2' - 1"

3' - 11" 0' - 7 1/2" 5' - 8 1/2"

SL

OP

E

1/

4"=

-1'-

0"

3" SOLID BLOCKINGAT END OF EACH

RAIL(TYP)

42" GUARDRAIL(TYP)

2R2S

12

1R

1S

SS

C 18

BALCONY

LIVING

BEDROOM

WIC

BATH

UTIL.

KITCHEN

DINING

VPC

T

C

8'-6"A.F.F.

8'-0"A.F.F.

8'-0"A.F.F.

3618

1842

3024

18423642

36" CAB. 18" CAB. 18" CAB.24" OPENFOR D.W.

30" OPENFOR RANGE

36" OPENFOR REF.

3" FILLER

3" FILLER MICROWAVE/VENTHOOD COMBO

TILE BULLNOSE

UTIL. 1"X34" = 34SQ.IN. FREEAREA

24"X83" = 1992SQ.IN. FREEAREA

A/C CLOSET

RETURN AIR VENT

UNDERCUT DOOR 1"

1 1/2" FILLER

FREE AREA REQUIREMENTS

TOTAL FREE AREA REQUIRED = 100 SQ.IN.TOTAL FREE AREA PROVIDED = 2026 SQ.IN.

15' - 11 3/4" R.O. 0' - 3 1/2"

23' - 8"

3' -

6"

1' -

6"

3' -

0"

8' -

0"

FURROUT

OPEN SHELVING

0' - 3 1/2" 4' - 8 3/4" R.O.

10' - 2"

1' -

6"

3' -

0"

3942

27" CAB.

3" FILLER1 1/2" FILLER

ENTRYDOOR 3" FILLER

FURROUT

DESK COATCLOSET36" PAN. FRONT

3' - 3 1/2"6' - 10 1/4" R.O.0' - 3 1/2"

15' - 6 1/2"

2' -

6"

2' -

0"

1' -

0"

2' -

6"

8' -

0"

1 1/2" FILLERFURROUT

4230

24" TB @4'-6" A.F.F.

1

TUB/SHOWER

SHOWER HEAD @ 7'-0" A.F.F.

3' - 0 3/4"

14' - 6 3/4"

3' -

5"

1' -

11

"

0' -

8"

1' -

3"

1' -

3"

8' -

6"

FURROUT

1

TUB/SHOWER

5' - 1 1/4"

5' - 7 1/4"

5' -

4"

1' -

5"

0' -

6"

1' -

3"

8' -

6"

FURROUT

11

30" VB15" DB TUB/SHOWER24" LIN. FRONT

3" FILLER

4" BACKSPLASH

MIRROR

1' - 6 1/2" 3' - 0 3/4"

14' - 6 3/4"

5' -

4"

0' -

8"

1' -

3"

1' -

3"

8' -

6"

1' -

0"

2' -

7"

4' -

2"

2' -

10

"

7' -

0"

FURROUT

30" VBWASHER/DRYER

3' - 6"

FLOOR FINISHES

VP - VINYL PLANK

C - CARPET

T - TILE

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:41

:57

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.10

UNIT A6 FLOOR PLANS & INT.ELEVATIONS

08/31/16

08/15/16

1/4" = 1'-0"1 UNIT A6 FLOOR PLAN 1/4" = 1'-0"2 UNIT A6 FINISH FLOOR PLAN

3/8" = 1'-0"3

UNIT A6 - KITCHEN ELEVATION 1, A/CCLOSET & MAKE UP AIR CALC.ELEVATION

3/8" = 1'-0"4 UNIT A6 - KITCHEN ELEVATION 2 3/8" = 1'-0"5 UNIT A6 - KITCHEN ELEVATION 3

3/8" = 1'-0"6 UNIT A6 - BATH ELEVATION 1 3/8" = 1'-0"7 UNIT A6 - BATH ELEVATION 2

3/8" = 1'-0"8 UNIT A6 - BATH ELEVATION 3 3/8" = 1'-0"9 UNIT A6 - UTILITY ELEVATION

1

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 15: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

REF.

DW

REF.

DW

BALCONY

BEDROOM

LIVING

WIC

BATH

UTIL.

KITCHENP

AN

.

1R

1S

LIN

EN

A/C& WH

2R2S

2R2S

SS

1R

1S

1R

1S

36"X48"SHOWER

36"X60"TUB

12

3

3

6

7

3

1

/A

3.1

13

/A

3.1

15

/A3.11 4

/A

3.1

11

1

/A

3.1

11

2

/A3.11 6

/A3.11 7

/A3.11 8/A3.11 10

/A

3.1

19

4

8' - 2 1/2" 2' - 11"

2' - 0 1/2"

1' - 10 1/2" 3' - 6" 1' - 3"

1' - 4"

1' - 6 1/2"

26' - 0 1/2"

6' -

0 1

/2

"4

' - 5

"3

' - 1

0 1

/2

"4

' - 2

"1

2' -

5 1

/2

"

2' -

7"

4' -

5 1

/2

"7

' - 1

"

1' -

2 1

/2

"

3' -

3 1

/2

"2

' - 3

"1

' - 8

"

1' -

11

1/

2"

1' -

9 1

/2

"

2' -

1"

1' -

6"

1' -

9 1

/2

"

1' -

11

1/

2"

2' - 5" 3' - 7" 2' - 1 1/2"

0' - 5 1/2" 0' - 10"

3' - 11" 1' - 11"

2' - 0 1/2"

4' - 5"

2' - 3 1/2"

1' - 7 1/2"

2' - 2"

SL

OP

E

1/

4"=

1'-

0"

3" SOLID BLOCKINGAT END OF EACH

RAIL(TYP)

42" GUARDRAIL(TYP)

A

C18C

14

' - 0

"1

4' -

1 1

/2

"

2' - 11" 4' - 6" 4' - 6" 8' - 7"

TR

NOTE: SEE WALLSECTIONS @ BALCONYAS DETAILING VARIES

PER FLOOR

BALCONY

BEDROOMLIVING

WIC

BATH

UTIL.

KITCHEN

CVP

C

T

VP T

8'-6"A.F.F.

7'-0"A.F.F.

8'-0"A.F.F.

TR

1

1

30" PAN. FRONT

3342

3024

36421242

36" CAB. 33" DB30" OPENFOR RANGE

3" FILLER MICROWAVE/VENTHOOD COMBO 1 1/2" FILLER

3" FILLER

TILE BACKSPLASH

13' - 2 3/4" R.O.

3' -

6"

1' -

6"

3' -

0"

8' -

0"

FURROUT

3618

3642

24" CAB.

3" FILLER

3" FILLER

1" FILLER

36" OPENFOR REF.

0' - 3 1/2" 7' - 5 1/2" R.O.

13' - 0 3/4"

3' -

0"

1' -

6"

3' -

6"

8' -

0"

ENTRYDOOR

TILEBULLNOSE

FURROUT

36" CAB.21" TRASH 24" OPENFOR D.W.

1" ENDPANEL

1" ENDPANEL

6' - 11"

13' - 8"

3' -

0"

3' -

0"

1' -

6"

3' -

6"

8' -

0"

FURROUT

1

SHOWER

SHOWER HEAD @ 7'-0" A.F.F.FURROUT

3' - 0 3/4"

10' - 1 1/4"

3' -

5"

1' -

11

"0

' - 8

"2

' - 6

"

8' -

6"

7' -

0"

FURROUT

1

SHOWER

SHOWERSEAT

GLASS

3' - 0 3/4"

4' -

6"

0' -

10

"0

' - 8

"2

' - 6

"

8' -

6"

1' -

6"

FURROUT

SHELF

1

TUB

GLASS

24" TB @4'-6" A.F.F.

5' - 3" 3' - 0 3/4"

12' - 1 1/4"

4' -

6"

0' -

10

"0

' - 8

"1

' - 3

"1

' - 3

"

8' -

6"

FURROUT

SHELF

11

GLASS ABOVE LOW WALL

SHOWER TUB

4' - 1 1/4" 0' - 5 1/2"

9' - 8"

1' -

3"0

' - 6

" 1' -

5"0

' - 1

0"

4' -

6"

8' -

6"

2' -

6"

0' -

8"

3' -

2"

1' -

6"

FURROUT

SHELF

1

3

1

30" VB 12"DB 30" VB

MIRROR

TUB 1 1/2" FILLER

4" BACKSPLASH

3' - 0 3/4" 1' - 6 1/2"1' - 4"

12' - 1 1/4"

2' -

10

"4

' - 2

"

7' -

0"

2' -

7"

1' -

0"

1' -

3"

1' -

3" 0

' - 8

"1' -

11

"3

' - 5

"

8' -

6"

FURROUT

WASHER/DRYER

3' - 7 1/4"

UTIL. 1"X34" = 34 SQ.IN. FREE AREA

24"X83" = 1992 SQ.IN. FREE AREA

A/C CLOSET

RETURN AIRVENT

UNDERCUTDOOR 1"

FREE AREA REQUIREMENTS

TOTAL FREE AREA REQUIRED = 100 SQ.IN.TOTAL FREE AREA PROVIDED = 2026 SQ.IN.

16' - 4 3/4"

FLOOR FINISHES

VP - VINYL PLANK

C - CARPET

T - TILE

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

BALCONY

LIVING

C

LEASING

EXTERIOR

0' -

10

"

0' - 6 1/2" 2' - 11"

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:41

:59

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.11

UNIT A7 FLOOR PLANS & INT.ELEVATIONS

08/31/16

08/15/16

1/4" = 1'-0"1 UNIT A7 FLOOR PLAN 1/4" = 1'-0"2 UNIT A7 FINISH FLOOR PLAN

3/8" = 1'-0"3 UNIT A7 - KITCHEN ELEVATION 1 3/8" = 1'-0"4 UNIT A7 - KITCHEN ELEVATION 2

3/8" = 1'-0"5 UNIT A7 - KITCHEN ELEVATION 3 3/8" = 1'-0"6 UNIT A7 - BATH ELEVATION 1

3/8" = 1'-0"7 UNIT A7 - BATH ELEVATION 2 3/8" = 1'-0"8 UNIT A7 - BATH ELEVATION 3

3/8" = 1'-0"9 UNIT A7 - BATH ELEVATION 4 3/8" = 1'-0"10 UNIT A7 - BATH ELEVATION 5

3/8" = 1'-0"11 UNIT A7 - UTILITY ELEVATION

3/8" = 1'-0"12

UNIT A7 - A/C CLOSET & MAKE UP AIRCALC. ELEVATION

1

1

1

1

1

1

1/4" = 1'-0"1A

UNIT A7 FLOOR PLAN @ ALT. BALC.RAILING

1

1

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 16: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

REF.

DW

REF.

DW

BALCONY

LIVING/KITCHEN

BEDROOM

UTIL.

WIC

BATH

PA

N.

A/C& WH

1R1S

1R1S

2R

2S

36"X60"TUB

LIN

EN

36"X48"SHOWER

/A

3.1

24

/A3.125

/A

3.1

21

2/

A3

.12

13

/A

3.1

26

/A

3.1

27

/A3.128

/A3.129

/A3.1210

/A3.1211

S9

1

3

3

3

5

3

7

6

9

3' - 4" 1' - 10 1/2"

2' - 0"

3' - 9" 2' - 9" 1' - 6 1/2"

18' - 7 1/2"

6' -

0 1

/2

"4

' - 5

"2

' - 8

"1

1' -

7 1

/2

"1

5' -

9 1

/2

"2

' - 0

"

43

' - 3

1/

2"

1' -

2 1

/2

"3

' - 0

1/

2"

2' -

3"

4' -

3 1

/2

"

2' -

3 1

/2

"

1' -

11

1/

2"

1' -

11

1/

2"

2' -

7"

1' -

8 1

/2

"

2' -

2"

1' -

6"

1' -

9 1

/2

"

42

' - 6

1/

2"

0' - 5 1/2"

0' - 1"

3' - 4" 5' - 5 1/2"

3' - 7" 3' - 9"

1' - 6 1/2"

1' - 10"

4' - 0" 1' - 11 1/2" 4' - 1" 1' - 3"

SL

OP

E

1/

4"=

1'-

0"

42" GUARDRAIL(TYP)

TR

D ABOVE

16

BALCONY

LIVING/KITCHEN

BEDROOM

UTIL.

WIC

BATH

C

VP

CVP

C

T

VP T

C T

7'-0"A.F.F.

8'-6"A.F.F.

TR

8'-0"A.F.F.

FLOOR FINISHES

VP - VINYL PLANK

C - CARPET

T - TILE

2" FILLER MICROWAVE/VENTHOOD COMBO 3" FILLER

3" FILLER30" OPENFOR RANGE

24" OPENFOR D.W.

36422142

3024

1842

24" PAN. FRONT 18" CAB. 21" TRASH 36" CAB.

15' - 3 3/4" R.O.

3' -

0"

1' -

6"

3' -

6"

0' -

3"

8' -

0"

TILE BACKSPLASH

FURROUT

OPEN SHELVING

3618

3642

24" CAB.

FURROUT 3" FILLER

TILEBULLNOSE

3" FILLER 36" OPENFOR REF.

7' - 7 1/4" R.O. 7' - 1 3/4"

18' - 0 1/2"

0' -

3"

3' -

6"

1' -

6"

3' -

0"

8' -

0"

3" FILLER

24" TB @4'-6" A.F.F.

6' - 6 1/2"

FURROUT1" FILLER

11

GLASS ABOVE LOW WALL

SHOWER TUB24" LIN. FRONT

2' - 4 1/4" R.O.

0' - 3 1/2"

4' - 1 1/4" 0' - 5 1/2"

12' - 3 3/4"

7' -

0"

1' -

3"0

' - 6

" 1' -

5"0

' - 1

0"

4' -

6"

8' -

6"

2' -

6"

0' -

8"

SHELF

1' -

6"

SHOWER

1

SHOWER HEAD @ 7'-0" A.F.F.

3' - 0 3/4"

7' - 0"

3' -

5"

1' -

11

"0

' - 8

"2

' - 6

"

8' -

6"

FURROUT

1

SHOWER

3' - 0 3/4"

4' -

6"

0' -

10

"

0' -

8"

2' -

6"

8' -

6"

1' -

6"

SHOWERSEAT

GLASS

FURROUT

SHELF

GLASS

1

TUB

1' -

3"

1' -

3"0

' - 8

"0

' - 1

0"

4' -

0"

3' - 0 3/4"

FURROUT

SHELF

1

1

12"DB33" VB 33" VB

MIRROR

4" BACKSPLASH

TUB

3' - 0 3/4" 1' - 6 1/2" 1' - 4 1/2"

12' - 7 3/4"

3' -

5"

1' -

11

"

0' -

8"

1' -

3"

1' -

3"

8' -

6"

1' -

0"

2' -

7"

4' -

2"

2' -

10

"

7' -

0"

1 1/2" FILLER

FURROUT

WASHER/DRYER

3' - 5 1/4"

UTIL. 1"X30" = 34 SQ.IN. FREE AREA

24"X83" = 1992 SQ.IN. FREE AREA

A/C CLOSET

RETURN AIR VENT

UNDERCUT DOOR 1"

FREE AREA REQUIREMENTS

TOTAL FREE AREA REQUIRED = 100 SQ.IN.TOTAL FREE AREA PROVIDED = 2026 SQ.IN.

9' - 9 1/4"

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

PL

AN

TE

R

PL

AN

TE

R

302 SF

A8-A ROOF TERRACE

LIVING/KITCHEN

42" GUARDRAIL TYP.

16

' - 0

"

16

' - 5

1/

2"

1' - 6"17' - 2 1/2"

20' - 2 1/2"

0' - 8 1/2" 0' - 8 1/2"

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:42

:01

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.12

UNIT A8 FLOOR PLANS & INT.ELEVATIONS

08/31/16

08/15/16

1/4" = 1'-0"1 UNIT A8 FLOOR PLAN 1/4" = 1'-0"2 UNIT A8 FINISH FLOOR PLAN

3/8" = 1'-0"4 UNIT A8 - KITCHEN ELEVATION 1 3/8" = 1'-0"5 UNIT A8 - KITCHEN ELEVATION 2

3/8" = 1'-0"6 UNIT A8 - BATH ELEVATION 1 3/8" = 1'-0"7 UNIT A8 - BATH ELEVATION 2

3/8" = 1'-0"8 UNIT A8 - BATH ELEVATION 3 3/8" = 1'-0"9 UNIT A8 - BATH ELEVATION 4

3/8" = 1'-0"10 UNIT A8 - BATH ELEVATION 5 3/8" = 1'-0"11 UNIT A8 - BATH ELEVATION 6

3/8" = 1'-0"12 UNIT A8 - UTILITY ELEVATION 3/8" = 1'-0"13

UNIT A8 - A/C CLOSET & MAKE UP AIRCALC. ELEVATION

1/4" = 1'-0"3 UNIT A8 AMENITY DECK ROOF TERRACE

11

1

1

1

1

1

1

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 17: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

REF.

DW

REF.

DW

BALCONY

LIVING/KITCHEN

BEDROOM

UTIL.

WIC

BATH

PA

N.

A/C& WH

1R1S

1R1S

2R

2S

36"X60"TUB

LIN

EN

36"X48"SHOWER

/A

3.1

2A

4

/A3.12A 5

/A

3.1

2A

12

/A

3.1

2A

13

/A

3.1

2A

6

/A

3.1

2A

7

/A3.12A 8

/A3.12A 9

/A3.12A 10

/A3.12A 11

9

6

7

5

3

3

3

3

1

S9

4' - 7"

1' - 10 1/2"

2' - 0"3' - 9"

1' - 4 1/2"

1' - 4 1/2"1' - 6 1/2"

19' - 10 1/2"

6' -

0"

4' -

5"

2' -

8"

11

' - 7

1/

2"

15

' - 9

1/

2"

2' -

1"

43

' - 3

1/

2"

1' -

2 1

/2

"3

' - 0

1/

2"

2' -

3"

4' -

3 1

/2

"2

' - 3

1/

2"

1' -

11

1/

2"

1' -

11

1/

2"

2' -

7"

1' -

8 1

/2

"

2' -

2"

1' -

6"

1' -

9 1

/2

"

42

' - 6

1/

2"

0' - 5"0' - 1"

3' - 1 1/2"3' - 0"3' - 11"

SL

OP

E

1/

4"=

1'-

0"

3" SOLID BLOCKINGAT END OF EACHRAIL(TYP)

42" GUARDRAIL(TYP)

TRD ABOVE

C 16

BALCONY

LIVING/KITCHEN

BEDROOM

UTIL.

WIC

BATH

C

VP

C VP

C

T

CT

VPT

7'-0"A.F.F.

8'-6"A.F.F.

8'-0"A.F.F.

TR

2" FILLERMICROWAVE/VENTHOOD COMBO3" FILLER

3" FILLER 30" OPENFOR RANGE

24" OPENFOR D.W.

TILE BACKSPLASH

15' - 3 3/4" R.O.

3642 2142

3024

1842

24" PAN. FRONT18" CAB.21" TRASH36" CAB.

0' -

3"

3' -

6"

1' -

6"

3' -

0"

8' -

0"

FURROUT

OPEN SHELVING

FURROUT3" FILLER

TILEBULLNOSE

3" FILLER36" OPENFOR REF.

7' - 1 3/4" 7' - 7 1/4" R.O.

19' - 3 1/2"

0' -

3"

3' -

6"

1' -

6"

3' -

0"

8' -

0"

3618

3642

24" CAB.

3" FILLER

24" TB @4'-6" A.F.F.

6' - 6 1/2"

FURROUT 11/2" FILLER

11

GLASS ABOVE LOW WALL

SHOWERTUB 24" LIN. FRONT

2' - 4 1/4"0' - 3 1/2"4' - 1 1/4"0' - 5 1/2"

12' - 3 3/4"

7' -

0"

4' -

6"

0' -

10

"

1' -

5"

0' -

6"

1' -

3"

8' -

6"

0' -

8"

2' -

6"

SHELF

1' -

6"

SHOWER

1

SHOWER HEAD @ 7'-0" A.F.F.

7' -

1"

3' - 0 3/4"

7' - 0"

3' -

5"

1' -

11

"0

' - 8

"2

' - 6

"

8' -

6"

FURROUT

1

SHOWER

SHOWERSEAT

GLASS

3' - 0 3/4"

4' -

6"

0' -

10

"0

' - 8

"2

' - 6

"

8' -

6"

4' -

0"

FURROUT

SHELF

GLASS

1

TUB

3' - 0 3/4"

4' -

6"

0' -

10

"

0' -

8"

1' -

3"

1' -

3"

8' -

6"

FURROUT

SHELF

1

14" BACKSPLASH

TUB33" VB12"DB33" VB

MIRROR

1 1/2" FILLER

1' - 4 1/2" 1' - 6 1/2" 3' - 0 3/4"

12' - 7 3/4"

3' -

5"

1' -

11

"0

' - 8

"1

' - 3

"1

' - 3

"

8' -

6"

1' -

0"

2' -

7"

4' -

2"

2' -

10

"

7' -

0"

FURROUT

WASHER/DRYER

3' - 5 1/4"

UTIL.1"X30" = 34 SQ.IN. FREE AREA

24"X83" = 1992 SQ.IN. FREE AREA

A/C CLOSET

RETURN AIR VENT

UNDERCUT DOOR 1"

3' - 11 1/4" 9' - 9 1/4"

FREE AREA REQUIREMENTS

TOTAL FREE AREA REQUIRED = 100 SQ.IN.TOTAL FREE AREA PROVIDED = 2026 SQ.IN.

FLOOR FINISHES

VP - VINYL PLANK

C - CARPET

T - TILE

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

CORRIDOR WALL.UNIT INTERIORDIMENSION REMAINSTHE SAME.

EXTERIOR WALL.UNIT INTERIORDIMENSION REMAINSTHE SAME.

Q1HR

E1 HR

4' - 9"1' - 10 1/2"

20' -1/2"

0' - 5 1/2"

0' - 1"

3' - 3"

10

' - 6

1/

2"

LIVING

CORRIDORUTIL.

A/C& WH

1R1S

(OPEN TOCORRIDOR

BELOW)

PL

AN

TE

R

PL

AN

TE

R

18' - 5 1/2"1' - 6"

21' - 5 1/2"

16

' - 0

"

16

' - 5

1/

2"

324 SF

A8-A ROOF TERRACE

LIVING/KITCHEN

42" GUARDRAIL TYP.

0' - 3" 0' - 8 1/2"

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:42

:02

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.12A

UNIT A8-A FLOOR PLANS &INT. ELEVATIONS

08/31/16

08/15/16

1/4" = 1'-0"1 UNIT A8-A FLOOR PLAN 1/4" = 1'-0"2 UNIT A8-A FINISH FLOOR PLAN

3/8" = 1'-0"4 UNIT A8-A - KITCHEN ELEVATION 1 3/8" = 1'-0"5 UNIT A8-A - KITCHEN ELEVATION 2

3/8" = 1'-0"6 UNIT A8-A - BATH ELEVATION 1 3/8" = 1'-0"7 UNIT A8-A - BATH ELEVATION 2

3/8" = 1'-0"8 UNIT A8-A - BATH ELEVATION 3 3/8" = 1'-0"9 UNIT A8-A - BATH ELEVATION 4

3/8" = 1'-0"10 UNIT A8-A - BATH ELEVATION 5 3/8" = 1'-0"11 UNIT A8-A - BATH ELEVATION 6

3/8" = 1'-0"12 UNIT A8-A - UTILITY ELEVATION 3/8" = 1'-0"13

UNIT A8-A - A/C CLOSET & MAKE UP AIRCALC. ELEVATION

1/4" = 1'-0"1A

UNIT A8-A FLOOR PLAN @ CORRIDOR &EXT. WALL

1/4" = 1'-0"3

UNIT A8-A AMENITY DECK ROOFTERRACE

1

1

1

1 1

1

11

1

1

1

11

1

No. Revision Date

1 REV 1 Date 1

Page 18: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

REF.

DW

REF.

DW

BALCONY

LIVING/KITCHEN

BEDROOM

UTIL.

BATH

WIC

PAN.A/C& WH

1R1S

LIN

EN

2R

2S

SS

1R1S

36"X48"SHOWER

36"X60"TUB

1

33

3

5

7

6

9

/A

3.1

33

/A3.134

/A

3.1

31

1/

A3

.13

12

/A

3.1

36

/A3.135

/A3.137

/A3.138

/A3.1310

/A

3.1

39

5' - 10" 9' - 3 1/2" 1' - 10 1/2"

20' - 4"

16

' - 1

0"

11

' - 6

1/

2"

12

' - 3

1/

2"

43

' - 6

"

4' - 8 1/2"3' - 2"3' - 0"4' - 5"

1' -

9 1

/2

"1

' - 6

"

2' -

2"

1' -

8 1

/2

"

2' -

7"

1' -

11

"

1' -

11

"

1' -

10

1/

2"

4' -

5"

4' -

10

"1

' - 2

1/

2"

3' -

9"

1' -

4 1

/2

"

1' -

4"

1' -

6 1

/2

"

0' -

5 1

/2

"

2' - 3" 3' - 6 1/2" 3' - 9 1/2" 2' - 3"

1' - 2 1/2"

1' - 6 1/2"

0' - 3 1/2"

3' - 5 1/2"1' - 10"1' - 10"9' - 4 1/2"

SL

OP

E

1/

4"=

1'-

0"

3" SOLID BLOCKINGAT END OF EACHRAIL(TYP)

42" GUARDRAIL(TYP)

TR

E ABOVE

16 C A

BALCONY

LIVING/KITCHEN

BEDROOM

UTIL.

BATH

WIC

C

VP

C VP

C

T

8'-0"A.F.F.

8'-6"A.F.F.

TR

E ABOVE

MICROWAVE/VENTHOOD COMBO 3" FILLER3" FILLER

3" FILLER 3" FILLER30" OPENFOR RANGE

24" OPENFOR D.W.

33" DB

3342

3024

3342 2442 2142

21" TRASH36" CAB.21" CAB.

TILE BACKSPLASH

3' -

0"

1' -

6"

3' -

6"

0' -

3"

16' - 4 1/2" R.O.

FURROUT

OPEN SHELVING

8' -

0"

24" PAN. FRONT

3618

3042

18" CAB.

3" FILLER

3" FILLER36" OPENFOR REF.

TILEBACKSPLASH

7' - 1 3/4" 9' - 1 1/4" R.O.

19' - 9"

3" FILLER FURROUT

0' -

3"

3' -

6"

1' -

6"

3' -

0"

8' -

0"

SHOWER

3' - 0 3/4"

8' - 9 3/4"

3' -

5"

1' -

11

"0

' - 8

"2

' - 6

"

8' -

6"

2' -

10

"

1

SHOWER HEAD @ 7'-0" A.F.F. FURROUT

33" VB12"DB33" VB

MIRROR

4" BACKSPLASH

1

1' - 6 1/2" 1' - 4"

1 1/2"FILLER

11' - 6 3/4"

2' -

7"

0' -

8"

3' -

3"

24" LIN. FRONT

2' -

10

"4

' - 2

"

7' -

0"

1

SHOWER

SHOWERSEAT

GLASS

3' - 0 3/4"

4' -

6"

0' -

10

"0

' - 8

"2

' - 6

"

8' -

6"

1' -

6"

FURROUT

SHELF

GLASS

1

TUB

3' - 0 3/4"

1' -

3"

1' -

3"0

' - 8

"0

' - 1

0"

4' -

6"

8' -

6"

FURROUT

SHELF

FURROUT

1

GLASS ABOVE LOW WALL

SHOWER TUB

0' - 5 1/2"4' - 1 1/4"1' - 10 3/4"

11' - 6 3/4"

0' -

8"

2' -

6"

4' -

6"

0' -

10

"1

' - 5

"0

' - 6

"1

' - 3

"

8' -

6"

1

1' -

6"

SHELF

1

1

TUB

24" TB @4'-6" A.F.F.

0' -

8"

2' -

7"

3' - 10" 0' - 10"

3' -

5"

1' -

11

"

0' -

8"

1' -

3"

1' -

3"

8' -

6"

8' - 9 3/4"

3' - 0 3/4"

3' -

3"

FURROUT

WASHER/DRYER

3' - 5 1/4"

UTIL.1"X30" = 34 SQ.IN. FREE AREA

24"X83" = 1992 SQ.IN. FREE AREA

A/C CLOSET

RETURN AIR VENT

UNDERCUT DOOR 1"

9' - 9 1/4"

FREE AREA REQUIREMENTS

TOTAL FREE AREA REQUIRED = 100 SQ.IN.TOTAL FREE AREA PROVIDED = 2026 SQ.IN.

FLOOR FINISHES

VP - VINYL PLANK

C - CARPET

T - TILE

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:42

:04

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.13

UNIT A9 FLOOR PLANS & INT.ELEVATIONS

08/31/16

08/15/16

1/4" = 1'-0"1 UNIT A9 FLOOR PLAN 1/4" = 1'-0"2 UNIT A9 FINISH FLOOR PLAN

3/8" = 1'-0"3 UNIT A9 - KITCHEN ELEVATION 1 3/8" = 1'-0"4 UNIT A9 - KITCHEN ELEVATION 2

3/8" = 1'-0"5 UNIT A9 - BATH ELEVATION 1 3/8" = 1'-0"6 UNIT A9 - BATH ELEVATION 2

3/8" = 1'-0"7 UNIT A9 - BATH ELEVATION 3 3/8" = 1'-0"8 UNIT A9 - BATH ELEVATION 4

3/8" = 1'-0"9 UNIT A9 - BATH ELEVATION 5 3/8" = 1'-0"10 UNIT A9 - BATH ELEVATION 6

3/8" = 1'-0"11 UNIT A9 - UTILITY ELEVATION

3/8" = 1'-0"12

UNIT A9 - A/C CLOSET & MAKE UP AIRCALC. ELEVATION

1

1

11

11

1

1

1

1

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 19: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

REF.

DW

DN20 19 18 17 16 15

14

13

12

11

10

9

8

UP

14

13

12

11

10

9

8

7

6

5

4

3

2

1

REF.

DW

BALCONY

BEDROOM

UTIL.

BATH

WIC

KITCHEN/DINING

PANTRY A/C& WH

1R1S

LIN

EN

1R

1S

SS

2R

2S

2R2S

36"X48"SHOWER

36"X60"TUB

/A

3.1

3B

1

/A3.13B2

/A

3.1

3B

9/

A3

.13

B1

0

/A

3.1

3B

3

/A3.13B4

/A3.13B5

/A3.13B6

/A3.13B7

/A

3.1

3B

8

9

6

7

5

3

33

1

CHASE

5' - 10" 9' - 3 1/2" 1' - 10 1/2"

20' - 4"

2' -

1"

11

' - 6

1/

2"

12

' - 3

1/

2"

43

' - 6

"

1' -

0"

3' -

1 1

/2

"6

' - 1

1/

2"

4' -

6"

1' -

9 1

/2

"

1' -

6"

2' -

2"

1' -

8 1

/2

"

2' -

7"

1' -

11

"

1' -

11

"

1' -

10

1/

2"

4' -

5"

4' -

10

"1

' - 2

1/

2"

1' -

4"

1' -

6 1

/2

"

0' -

5 1

/2

"

3' - 5 1/2"1' - 10"1' - 10"6' - 11 1/2"2' - 5"

4' - 8 1/4"3' - 2"3' - 0"4' - 5 1/4"0' - 0"

4' - 5"4' - 8 1/2"

SL

OP

E

1/

4"=

1'-

0"

3" SOLID BLOCKINGAT END OF EACHRAIL(TYP)

42" GURARDRAIL(TYP)

3' -

9"

1' -

4 1

/2

"

2' - 3" 3' - 6 1/2" 3' - 11 1/2" 2' - 1"

1' - 2 1/2"

1' - 6"

0' - 4"

TR

D ABOVE

16 C

A

LIVING

1/2BATH WET BAR

/A3.13B12

/A

3.1

3B

11

/A3.13B13

3

1' - 10" 2' - 8 1/2" 2' - 10" 3' - 3 1/2" 3' - 7"

20' - 4"

2' -

10

"1

' - 9

"1

4' -

4 1

/2

"2

' - 3

"

0' - 6"

0' - 7"

3' - 4 1/2" 3' - 0" 3' - 2" 4' - 8 1/2"

5' -

8"

8' -

9 1

/2

"4

' - 0

"2

' - 5

"

22

' - 7

1/

2"4' - 6 3/4"5' - 2 1/2"

PATIOA

C16

BALCONY

KITCHEN/DINING

BEDROOM

UTIL.

BATH

WIC

C

VP

C VP

C

T

8'-0"A.F.F.

8'-6"A.F.F.

TR

D ABOVE

LIVING

1/2 BATHWET BAR

VPT

9'-6"A.F.F.TYP.

8'-0"A.F.F.

PATIO

FLOOR FINISHES

VP - VINYL PLANK

C - CARPET

T - TILE

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:42

:04

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.13A

UNIT A9.2 FLOOR PLANS

08/31/16

08/15/16

1/4" = 1'-0"1 UNIT A9.2 FLOOR PLAN

1/4" = 1'-0"2 UNIT A9.1 FLOOR PLAN

1/4" = 1'-0"3 UNIT A9.2 FINISH FLOOR PLAN

1/4" = 1'-0"4 UNIT A9.1 FINISH FLOOR PLAN

11

11

1

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 20: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

MICROWAVE/VENTHOOD COMBO 3" FILLER1 1/2" FILLER

1 1/2" FILLER 3" FILLER30" OPENFOR RANGE

24" OPENFOR D.W.

TILE BACKSPLASH

3342

3024

2142 2442 2142

21" TRASH36" CAB.21" CAB. 33" DB

3' -

0"

1' -

6"

3' -

6"

0' -

3"

8' -

0"

FURROUT

14' - 3 1/4"

16' - 4 1/2"

OPEN SHELVING

3" FILLER 1 1/2" FILLER

1 1/2" FILLER36" OPENFOR REF.

TILE BACKSPLASH

3618

24" PAN. FRONT

1842

18" CAB.

7' - 1 3/4" 6' - 11 3/4" R.O. 2' - 1 1/2"

19' - 9"

FURROUT

0' -

3"

3' -

0"

1' -

6"

3' -

6"

8' -

0"

4" BACKSPLASH

1

1 1/2"FILLER

33" VB 12"DB 33" VB

MIRROR

1' - 4"1' - 6 1/2"

11' - 6 3/4"

2' -

7"

0' -

8"

2' -

10

"4

' - 2

"

24" LIN. FRONT

7' -

0"

SHOWER

1

SHOWER HEAD @ 7'-0" A.F.F.

3' - 0 3/4"

8' - 10"

1' -

11

"0

' - 8

"2

' - 6

"

5' -

1"

2' -

10

"

FURROUT

1

SHOWER

SHOWERSEAT

GLASS

3' - 0 3/4"

4' -

6"

0' -

10

"

0' -

8"

2' -

6"

8' -

6"

1' -

6"

FURROUT

SHELF

GLASS

1

TUB

3' - 0 3/4"

0' -

10

"0

' - 8

"1

' - 3

"1

' - 3

"

4' -

0"

FURROUT

SHELF

1

1

TUB

24" TB @4'-6" A.F.F.

0' -

8"

2' -

7"

3' - 10" 0' - 10"

3' - 0 3/4"

8' - 10"

3' -

5"

1' -

11

"

0' -

8"

1' -

3"

1' -

3"

8' -

6"

FURROUT

1

GLASS ABOVE LOW WALL

SHOWER TUB

1

0' - 5 1/2"4' - 1 1/4"1' - 10 3/4"

11' - 6 3/4"

0' -

8"

2' -

6"

4' -

6"

0' -

10

"1

' - 5

"0

' - 6

"1

' - 3

"

8' -

6"

FURROUT

1' -

6"

SHELF

WASHER/DRYER

3' - 5 1/4"

UTIL.1"X30" = 34 SQ.IN. FREE AREA

24"X83" = 1992 SQ.IN. FREE AREA

A/C CLOSET

RETURN AIR VENT

UNDERCUT DOOR 1"

9' - 9 1/4"

FREE AREA REQUIREMENTS

TOTAL FREE AREA REQUIRED = 100 SQ.IN.TOTAL FREE AREA PROVIDED = 2026 SQ.IN.

1

2' -

7"

0' -

8"

1' -

3"

2' -

6"

0' - 10" 3' - 10"

5' - 9 1/4"

7' -

0"

12"DB 33" VB

1

MIRROR

4" BACKSPLASH

4' -

2"

2' -

10

"

7' -

0"

1' -

3"

0' -

8"

2' -

7"

1 1/2" FILLER1' - 4" 1' - 6 1/2"

6' - 9 3/4"

24302442

27" CAB.

1 1/2" FILLER1 1/2" FILLER

1 1/2" FILLER 24"BEVERAGE

COOLER

6' - 7 1/4" R.O.

3' -

0"

1' -

6"

3' -

6"

8' -

0"

TILEBACKSPLASH

FURROUT

2442

OPENSHELVING

24" CAB. 1 1/2" FILLER

(GLASSFRONT)

(GLASSFRONT)

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:42

:06

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.13B

UNIT A9.2 INT. ELEVATIONS

08/31/16

08/15/16

3/8" = 1'-0"1 UNIT A9.2 - KITCHEN ELEVATION 1 3/8" = 1'-0"2 UNIT A9.2 - KITCHEN ELEVATION 2

3/8" = 1'-0"3 UNIT A9.2 - BATH ELEVATION 1 3/8" = 1'-0"4 UNIT A9.2 - BATH ELEVATION 2

3/8" = 1'-0"5 UNIT A9.2 - BATH ELEVATION 3 3/8" = 1'-0"6 UNIT A9.2 - BATH ELEVATION 4

3/8" = 1'-0"7 UNIT A9.2 - BATH ELEVATION 5 3/8" = 1'-0"8 UNIT A9.2 - BATH ELEVATION 6

3/8" = 1'-0"9 UNIT A9.2 - UTILITY ELEVATION

3/8" = 1'-0"10

UNIT A9.2 - A/C CLOSET & MAKE UP AIRCALC. ELEVATION

3/8" = 1'-0"11 UNIT A9.1 - 1/2 BATH ELEVATION 1 3/8" = 1'-0"12 UNIT A9.1 - 1/2 BATH ELEVATION 2

3/8" = 1'-0"13 UNIT A9.1 - WET BAR ELEVATION

1

1

1

1

1

1

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 21: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

REF.

DW

REF.

DW

BALCONY

KITCHEN

LIVING

BEDROOM

UTIL.

WIC

BATH

PA

N.

A/C& WH

1R1S

LIN

EN

1R1S

2R

2S

36"X48"SHOWER

36"X60"TUB

1

3

3

3

3

5

7

6

9

/A

3.1

44

/A

3.1

46

/A3.14 5

/A

3.1

41

3/

A3

.14

14

/A3.14 7

/A3.14 9

/A

3.1

48

/A3.14 10

/A

3.1

41

1

/A3.14 12

S1

3' - 4" 1' - 6 1/2"

1' - 4 1/2"

1' - 4 1/2"

3' - 7 1/2"

1' - 10 1/2"

2' - 0 1/2"

22' - 11"

6' -

0 1

/2

"4

' - 5

"2

' - 8

"1

1' -

7 1

/2

"1

5' -

9 1

/2

"2

' - 0

"

43

' - 3

1/

2"

4' - 8" 3' - 0" 2' - 0 1/2"

0' - 1" 0' - 5 1/2"

18' - 6 1/2" 4' - 4 1/2"

24

' - 6

1/

2"

18

' - 0

"

1' -

2 1

/2

"

3' -

0 1

/2

"

2' -

3"

4' -

3 1

/2

"

2' -

3 1

/2

"

1' -

11

1/

2"

1' -

11

1/

2"

2' -

7"

1' -

8 1

/2

"

2' -

2"

1' -

6"

1' -

9 1

/2

"4

' - 4

"5

' - 4

"

1' - 6 1/2"

3' - 9 1/2" 2' - 3" 3' - 8"

1' - 9 1/2"

1' - 9 1/2"

7' - 10" 1' - 10"

1' - 6 1/2"

6' - 2 1/2" 2' - 1 1/2"

0' - 5 1/2"

0' - 10"

SL

OP

E

1/

4"=

1'-

0"

42" GUARDRAIL(TYP)

D ABOVE

16 C

BALCONY

KITCHEN

LIVING

BEDROOM

UTIL.

WIC

BATH

C

VP

C VP

C

T

CT

VPT

8'-0"A.F.F.

3342 3642

3024

3642

36" DB 30" PAN. FRONT36" CAB.21" TRASH 30" OPENFOR RANGE

3" FILLER

3" FILLER 2 1/2" FILLERMICROWAVE/VENTHOOD COMBO

TILE BACKSPLASH

0' -

3"

3' -

6"

1' -

6"

3' -

0"

8' -

0"

15' - 3 3/4" R.O.

FURROUT

TILE BACKSPLASH

2 1/2" FILLER FURROUT

3618

3642

24" CAB. 3" FILLER36" OPENFOR REF.

7' - 6 3/4" R.O.

14' - 6 1/2"

2' -

8 1

/2

"1

' - 6

"3

' - 6

"0

' - 3

"

7' -

8 1

/2

"

3" FILLER

36" CAB.24" OPENFOR D.W.

OPEN TOLIVING

3' -

0"

3' - 8 3/4" 5' - 0"

15' - 3 3/4"

1" ENDPANEL

1" ENDPANEL

SHOWER HEAD @ 7'-0" A.F.F.

SHOWER

3' - 0 3/4"

7' - 0"

1

3' -

5"

1' -

11

"0

' - 8

"2

' - 6

"

8' -

6"

FURROUT

24" TB @4'-6" A.F.F.

6' - 6 1/2"

GLASS

1

1' -

6"

4' -

6"

0' -

10

"0

' - 8

"2

' - 6

"

8' -

6"

SHOWER

3' - 0 3/4"

FURROUT

SHOWERSEAT

SHELF

1

GLASS

TUB

0' -

10

"

0' -

8"

1' -

3"

1' -

3"

4' -

0"

3' - 0 3/4"

FURROUT

SHELF

FURROUT 1 1/2" FILLER

1

SHOWERTUB

1

24" LIN. FRONT

2' - 4 1/4"0' - 3 1/2"4' - 1 1/4"0' - 5 1/2"

12' - 3 3/4"

4' -

6"

0' -

10

"

1' -

5"

0' -

6"

1' -

3"

8' -

6"

0' -

8"

2' -

6"

7' -

0"

GLASS ABOVELOW WALL

1' -

6"

SHELF

33" VB12"DB30" VB TUB

1

1

MIRROR

4" BACKSPLASH

1' - 4 1/2" 1' - 6 1/2" 3' - 0 3/4"

12' - 4 3/4"

1' -

11

"0

' - 8

"1

' - 3

"1

' - 3

"

5' -

1"

1' -

0"

2' -

7"

4' -

2"

2' -

10

"

7' -

0"

1 1/2" FILLER

FURROUT

WASHER/DRYER

3' - 5 1/4"

UTIL.1"X34" = 34 SQ.IN. FREE AREA

24"X83" = 1992 SQ.IN. FREE AREA

A/C CLOSET

RETURN AIR VENT

UNDERCUT DOOR 1"

FREE AREA REQUIREMENTS

TOTAL FREE AREA REQUIRED = 100 SQ.IN.TOTAL FREE AREA PROVIDED = 2026 SQ.IN.

9' - 9 1/4"

FLOOR FINISHES

VP - VINYL PLANK

C - CARPET

T - TILE

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

PL

AN

TE

R

PL

AN

TE

R

374 SF

A10 ROOF TERRACE

LIVING/KITCHEN

42" GUARDRAIL TYP.

0' - 8 1/2" 0' - 8 1/2"

0' -

6 1

/2

"1

6' -

0"

18

' - 6

1/

2"

1' - 6"21' - 6"

24' - 6"

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:42

:07

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.14

UNIT A10 FLOOR PLANS & INT.ELEVATIONS

08/15/16

08/15/16

1/4" = 1'-0"1 UNIT A10 FLOOR PLAN 1/4" = 1'-0"2 UNIT A10 FINISH FLOOR PLAN

3/8" = 1'-0"4 UNIT A10 - KITCHEN ELEVATION 1 3/8" = 1'-0"5 UNIT A10 - KITCHEN ELEVATION 2

3/8" = 1'-0"6 UNIT A10 - KITCHEN ELEVATION 3 3/8" = 1'-0"7 UNIT A10 - BATH ELEVATION 1

3/8" = 1'-0"8 UNIT A10 - BATH ELEVATION 2 3/8" = 1'-0"9 UNIT A10 - BATH ELEVATION 3

3/8" = 1'-0"10 UNIT A10 - BATH ELEVATION 4 3/8" = 1'-0"11 UNIT A10 - BATH ELEVATION 5

3/8" = 1'-0"12 UNIT A10 - BATH ELEVATION 6

3/8" = 1'-0"13 UNIT A10 - UTILITY 3/8" = 1'-0"14

UNIT A10 - A/C CLOSET & MAKE UP AIRCALC. ELEVATION

1/4" = 1'-0"3

UNIT A10 AMENITY DECK ROOFTERRACE

1

1

1

1

1

1

11

1

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 22: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

REF.

DW

REF.

DW

BALCONY

LIVING

STUDY/DINING

BEDROOM

WIC

UTIL.

KITCHEN

BATH

A/C& WH

1R

1S

LIN

EN

36"X48"SHOWER

36"X60"TUB

SS

1R

1S

2R2S

1R

1S

2R2S

PANTRY

A

3

6

12

7

3

4

3

1

/A3.15 3

/A

3.1

51

4

/A3.15 13

/A

3.1

51

2

/A

3.1

59

/A3.15 6

/A

3.1

57

/A3.15 8

/A3.15 10

/A3.15 11/

A3

.15

4/A3.15 5

S1

11' - 9" 2' - 11"

2' - 0 1/2"

2' - 0" 3' - 9" 1' - 4 1/2"

1' - 4"

1' - 6 1/2"

30' - 1"

11

' - 0

1/

2"

1' -

0"

16

' - 1

"

6' -

0 1

/2

"4

' - 5

"3

' - 6

"3

' - 9

1/

2"

13

' - 2

1/

2"

4' - 5" 10' - 4" 5' - 3" 5' - 6 1/2"

2' -

7"

1' -

2 1

/2

"

3' -

2 1

/2

"

2' -

0 1

/2

"

1' -

11

1/

2"

2' -

0"

1' -

9"

2' -

0 1

/2

"

3' -

1 1

/2

"1

' - 1

1 1

/2

"

10' - 9" 4' - 5 1/2" 1' - 11 1/2"

2' - 1" 2' - 3 1/2"

2' - 3"

1' - 9 1/2"2' - 7"

42" GUARDRAIL(TYP)

3" SOLID BLOCKINGAT END OF EACH

RAIL(TYP)

TR

18

BALCONY

LIVING

STUDY/DINING

BEDROOM

WIC

UTIL.

KITCHEN

BATH

TVP

T

C

CVP

8'-0"A.F.F.

8'-6"A.F.F.

7'-0"A.F.F.

TR

OPEN TOLIVING

21" TRASH 36" CAB.3" FILLER 24" OPENFOR D.W.

1" ENDPANEL

3' -

6"

1' -

6"

3' -

0"

8' -

0"

10' - 5 3/4"

14' - 11"

FURROUT

15" CAB.

1842

3024

3042

18" CAB. 18" CAB.

3" FILLER MICROWAVE/VENTHOOD COMBO

3" FILLER 3" FILLER

TILE BULLNOSE

3' -

6"

1' -

6"

3' -

0"

8' -

0"

10' - 1 1/4" R.O. 0' - 5 1/2"

11' - 6 3/4"

30" OPENFOR RANGE

FURROUT

TILEBACKSPLASH

3" FILLER1 1/2" FILLER

3' -

0"

1' -

6"

3' -

6"

8' -

0"

3" FILLER36" DB

3642 1242

30" PAN. FRONT

3618

ENTRYDOOR 36" OPENFOR REF.

0' - 3 1/2" 10' - 11 3/4" R.O.

16' - 7"

FURROUTFURROUT

24" TB @4'-6" A.F.F.

SHOWER HEAD @ 7'-0" A.F.F.

SHOWER

1

3' - 0 3/4"

11' - 11 3/4"

3' -

5"

1' -

11

"0

' - 8

"2

' - 6

"

8' -

6"

7' -

0"

FURROUT

36" LIN. FRONT

1 1/2" FILLER

3' - 4 1/4"0' - 3 1/2"

9' - 8"

7' -

0"

2' -

10

"

FURROUT

1

SHOWER

SHOWERSEAT

GLASS

3' - 0 3/4"

4' -

6"

0' -

10

"0

' - 8

"2

' - 6

"

8' -

6"

FURROUT

SHELF

1' -

6"

11

SHOWER TUB

2' -

6"

0' -

8"

0' -

10

"4

' - 6

"

8' -

6"

1' -

6"

1' -

3"0

' - 6

" 1' -

5"

3' -

2"

0' - 5 1/2"4' - 1 1/4"

9' - 8"

GLASS ABOVE LOW WALLFURROUT

SHELF

1

TUB

GLASS

3' - 0 3/4"

4' -

6"

0' -

10

"

0' -

8"

1' -

3"

1' -

3"

8' -

6"

FURROUT

SHELF

33" VB 12"DB 33" VB

1

1

MIRROR

4" BACKSPLASH

1 1/2" FILLERTUB

3' - 0 3/4" 1' - 6 1/2" 1' - 4"

12' - 7 1/4"

1' -

3"

1' -

3" 0

' - 8

"1' -

11

"3

' - 5

"

8' -

6"

2' -

7"

1' -

0"

2' -

10

"4

' - 2

"

7' -

0"

FURROUT

WASHER/DRYER

3' - 6"

A/C CLOSET

RETURN AIRVENT

UNDERCUTDOOR 1"

3' - 9 1/4"

UTIL. 1"X30" = 34 SQ.IN. FREE AREA

24"X83" = 1992 SQ.IN. FREE AREA

UNDERCUT DOOR 1"

FREE AREA REQUIREMENTS

TOTAL FREE AREA REQUIRED = 100 SQ.IN.TOTAL FREE AREA PROVIDED = 2026 SQ.IN.

10' - 10 1/4"

16' - 1 1/2"

FLOOR FINISHES

VP - VINYL PLANK

C - CARPET

T - TILE

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:42

:09

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.15

UNIT A11 FLOOR PLANS & INT.ELEVATIONS

08/31/16

08/15/16

1/4" = 1'-0"1 UNIT A11 FLOOR PLAN 1/4" = 1'-0"2 UNIT A11 FINISH FLOOR PLAN

3/8" = 1'-0"3 UNIT A11 - KITCHEN ELEVATION 1 3/8" = 1'-0"4 UNIT A11 - KITCHEN ELEVATION 2

3/8" = 1'-0"5 UNIT A11 - KITCHEN ELEVATION 3 3/8" = 1'-0"6 UNIT A11 - BATH ELEVATION 1

3/8" = 1'-0"7 UNIT A11 - BATH ELEVATION 2 3/8" = 1'-0"8 UNIT A11 - BATH ELEVATION 3

3/8" = 1'-0"9 UNIT A11 - BATH ELEVATION 4 3/8" = 1'-0"10 UNIT A11 - BATH ELEVATION 5

3/8" = 1'-0"11 UNIT A11 - BATH ELEVATION 6

3/8" = 1'-0"12 UNIT A11 - UTILITY ELEVATION 3/8" = 1'-0"13 UNIT A11 - A/C CLOSET ELEVATION

3/8" = 1'-0"14

UNIT A11 - MAKE UP AIR CALC.ELEVATION

1

1

1

1

1

1

1

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 23: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

REF.

DW

REF.

DW

BALCONY

KITCHEN

LIVING

BATH

BEDROOM

UTIL.

WIC

PAN.

SS1R1S

2R

2S

1R1S

2R

2S

A/C& WH

1R

1S

36"X60"TUB/

SHOWER

36"X48"SHOWER L

IN.

S1S19

16

2 96

13

4

3

2

1

/A

3.1

6A

1

/A3.16A2

/A

3.1

6A

9

/A

3.1

6A

10

/A

3.1

6A

3

/A

3.1

6A

6/A3.16A5

/A3.16A4

/A

3.1

6A

7

/A

3.1

6A

8

1' -

1"

14

' - 1

0"

5' -

5 1

/2

"1

2' -

4 1

/2

"1

0' -

2"

0' - 3 1/2"

1' - 6 1/2"

1' - 6"

2' - 3" 3' - 6" 5' - 11 1/2" 2' - 11"

20' - 4"

2' -

1 1

/2

"

4' -

6"

1' -

9 1

/2

"

1' -

6"

3' -

0 1

/2

"2

' - 9

"2

' - 3

"

1' -

11

1/

2"

5' -

5"

1' -

11

"1

' - 7

1/

2"

1' -

2 1

/2

"

4' - 10" 4' - 10"

1' - 6 1/2"

1' - 6 1/2"

3' - 10 1/2"

1' - 8" 5' - 6" 2' - 6 1/2" 7' - 7"

22' - 2"

4' - 8 1/2"

1' - 9 1/2"

3' - 0 1/2"

SL

OP

E

1/

4"=

1'-

0"

3' SOLID BLOCKINGAT END OF EACH

RAIL(TYP)

42" GUARDRAIL(TYP)

/A

3.1

AS

19

DINING

47

' - 0

"

49

' - 3

"

BALCONY

KITCHEN

LIVING

BATH

BEDROOM

UTIL.

WIC

C

VP

T

C

C VP

8'-0"A.F.F.

8'-6"A.F.F.

8'-6"A.F.F.

DINING

FLOOR FINISHES

VP - VINYL PLANK

C - CARPET

T - TILE

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2-A3.2A FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

ADAPTABLE ELEMENTS FOR TYPE A UNITSPER ICC/ANSI A117.1-2003 SEE SHEETS A1.4-A1.4F

REMOVABLE SINK BASE CABINET IN KITCHEN W/REAR DRAIN SINK. PROVIDE PANEL TO COVERPIPING, GARBAGE DISPOSAL, ETC., OR WRAPEXPOSED PIPING, IF CABINET IS REMOVED.EXTENDFLOORING UNDER CABINET & FINISH ADJACENTWALL SURFACES/CABINETS AT TIME OF INITIALCONSTRUCTION.

REMOVABLE BASE CABINET TO KITCHEN TOPROVIDE MIN. 30" WORK SPACE. FINISHADJACENTWALL SURFACES/CABINETS AT TIME OF INITIALCONSTRUCTION.

OVENS, RANGES, AND OTHER COOKING DEVICESSHALL HAVE UPFRONT CONTROLS.

DOOR PULLS OR HANDLES FOR WALL CABINETSSHALL BE MOUNTED AS CLOSE TO THE BOTTOMOF CABINET DOORS AS POSSIBLE. DOOR PULLSORHANDLES FOR BASE CABINETS SHALL BE MOUNTEDAS CLOSE TO THE TOP OF CABINET DOORS ASPOSSIBLE.

REFRIGERATOR/FREEZERS MUST BE OF THEVERITCAL SIDE-BY-SIDE TYPE; OR OF THEVERTICAL OVER-AND-UNDER TYPE WITH ATLEAST 50% OF THE FREEZER SPACE BELOW 54°ABOVE THE FLOOR AND 100% OF THEREFRIGERATOR SPACE AND CONTROLS BELOW 54".

REMOVABLE SINK BASE CABINET IN BATHROOM.PROVIDE PANEL TO COVER PIPING, OR WRAPEXPOSED PIPING IF CABINET IS REMOVED.EXTENDFLOORING UNDER CABINET AND FINISH ADJACENTWALL SURFACES/CABINETS AT TIME OF INITIALCONSTRUCTION.

GRAB BARS INSTALLED AT REQUEST OF FUTURETENANT, BUT BLOCKING MUST BE PROVIDED AT TIMEOF INITIAL CONSTRUCTION.

PROVIDE HANDHELD SHOWERHEAD, HOSE &VERTICAL BAR.

FOLDING SHOWER SEAT INSTALLED AT REQUESTOF FUTURE TENANT, BUT BLOCKING MUST BEPROVIDED AT TIME OF INITIAL CONSTRUCTION.

REMOVABLE BASE IN BATHROOM TO PROVIDEREQUIRED CLEAR FLOOR AREA FOR WATERCLOSET OR BATHTUB. PROVIDE WALL MOUNTEDEND PANEL TO SUPPORT COUNTERTOP. FINISHADJACENT WALL SURFACES/CABINETS AT TIME OFINITIAL CONSTRUCTION.

SEE SHEETS A1.3 & A1.3A FOR FURTHERINFORMATION

HC1

HC2

HC3

HC4

HC5

HC6

HC7

HC8

HC9

HC10

8/

31

/2

01

6 9

:42

:10

AM

CWS

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T

13

01

W. 5

TH

ST

.A

U ST

IN, T

X 7

87

03

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.16

UNIT A12-HC FLOOR PLANS

08/31/16

08/15/16

03/21/16

1/4" = 1'-0"1 UNIT A12-HC FLOOR PLAN 1/4" = 1'-0"2 UNIT A12-HC FINISH FLOOR PLAN

1

1 1

1

No. Revision Date

1 REV 1 Date 1

Page 24: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

SHELF

SHELF

1242 3342

3024

2742

?

2442

33" CAB.27" CAB.33" CAB. 30" OPENFOR RANGE

24" OPENFOR D.W.

VENTHOOD3" FILLER 3" FILLER

3" FILLER3" FILLER

TILEBACKSPLASH

14' - 10 1/4" R.O.

2' -

10

"1

' - 8

"3

' - 6

"

8' -

0"

COUNTERTOPMICROWAVE

HC1HC2HC3

FURROUT

15' - 5 1/2"

3" FILLER3" FILLER

3" FILLER

2442

30" PAN. FRONT

3618

12" CAB.36" OPENFOR REF.

9' - 1 1/4" R.O.

9' - 4 3/4"

3' -

6"

1' -

8"

2' -

10

"

8' -

0"

HC5

TILEBACKSPLASH

FURROUT

HC7

HC7

HC824" TB @4'-0" A.F.F.

SHOWER

9' - 5"

HAND HELDSHOWER HEAD

SHOWER HEAD@ 7'-0" A.F.F.

FURROUT

3' - 0 3/4"

3' - 10"0' - 10"

2' -

7"

0' -

8"

3' -

3"

2' -

6"

0' -

8"

1' -

11

"3

' - 5

"

8' -

6"

14' - 3 3/4"

TUB/SHOWER

HC7HC7

FURROUT

8' - 2 1/2" 1' - 6" 1' - 6 1/2"

0' -

8"

2' -

7"

3' -

3"

4' -

2"

2' -

10

"

12"DB30" VB30" VB12"DB

5' -

4"

0' -

8"

1' -

3"

1' -

3"

8' -

6"

4" BACKSPLASH

MIRROR

HC6

12"DB

SHOWER

5' -

4"

0' -

8"

2' -

6"

8' -

6"

4' - 1 1/4" 2' - 1 1/4" 5' - 0 3/4"

14' - 3 3/4"

HC7

FURROUT

TUB/SHOWER

3' -

5"

1' -

11

"

0' -

8"

1' -

3"

1' -

3"

8' -

6"

HC7

HC8

HAND HELDSHOWER HEAD

SHOWER HEAD@ 7'-0" A.F.F.

FURROUT

1' -

6"HC7

HC9

SHOWER

HC7

3' - 0 3/4"

FURROUT

5' -

4"

0' -

8"

0' -

6"

2' -

0"

8' -

6"

SHOWERSEAT

1' -

6"

5' -

4"

1' -

5"

0' -

6"

1' -

3"

8' -

6"

9' - 5"

HC7

2' -

10

"

5' - 1 1/4"

TUB/SHOWER

FURROUT

3' - 0 3/4"

2' - 9 1/4"

30" LIN. FRONT

1" FILLERFURROUT

WASHER & DRYER

5' - 6"

4' -

8"

1' -

2"

5' -

10

"

UTIL.1"X60" = 60 SQ.IN. FREE AREA

2 X (22"X83") = 3652 SQ.IN. FREE AREA

UNDERCUT DOOR 1"

FREE AREA REQUIREMENTS

TOTAL FREE AREA REQUIRED = 100 SQ.IN.TOTAL FREE AREA PROVIDED = 3712 SQ.IN.

A/C CLOSET

RETURN AIR VENT

9' - 4 1/2"

13' - 3 3/4"

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2-A3.2A FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

ADAPTABLE ELEMENTS FOR TYPE A UNITSPER ICC/ANSI A117.1-2003 SEE SHEETS A1.4-A1.4F

REMOVABLE SINK BASE CABINET IN KITCHEN W/REAR DRAIN SINK. PROVIDE PANEL TO COVERPIPING, GARBAGE DISPOSAL, ETC., OR WRAPEXPOSED PIPING, IF CABINET IS REMOVED.EXTENDFLOORING UNDER CABINET & FINISH ADJACENTWALL SURFACES/CABINETS AT TIME OF INITIALCONSTRUCTION.

REMOVABLE BASE CABINET TO KITCHEN TOPROVIDE MIN. 30" WORK SPACE. FINISHADJACENTWALL SURFACES/CABINETS AT TIME OF INITIALCONSTRUCTION.

OVENS, RANGES, AND OTHER COOKING DEVICESSHALL HAVE UPFRONT CONTROLS.

DOOR PULLS OR HANDLES FOR WALL CABINETSSHALL BE MOUNTED AS CLOSE TO THE BOTTOMOF CABINET DOORS AS POSSIBLE. DOOR PULLSORHANDLES FOR BASE CABINETS SHALL BE MOUNTEDAS CLOSE TO THE TOP OF CABINET DOORS ASPOSSIBLE.

REFRIGERATOR/FREEZERS MUST BE OF THEVERITCAL SIDE-BY-SIDE TYPE; OR OF THEVERTICAL OVER-AND-UNDER TYPE WITH ATLEAST 50% OF THE FREEZER SPACE BELOW 54°ABOVE THE FLOOR AND 100% OF THEREFRIGERATOR SPACE AND CONTROLS BELOW 54".

REMOVABLE SINK BASE CABINET IN BATHROOM.PROVIDE PANEL TO COVER PIPING, OR WRAPEXPOSED PIPING IF CABINET IS REMOVED.EXTENDFLOORING UNDER CABINET AND FINISH ADJACENTWALL SURFACES/CABINETS AT TIME OF INITIALCONSTRUCTION.

GRAB BARS INSTALLED AT REQUEST OF FUTURETENANT, BUT BLOCKING MUST BE PROVIDED AT TIMEOF INITIAL CONSTRUCTION.

PROVIDE HANDHELD SHOWERHEAD, HOSE &VERTICAL BAR.

FOLDING SHOWER SEAT INSTALLED AT REQUESTOF FUTURE TENANT, BUT BLOCKING MUST BEPROVIDED AT TIME OF INITIAL CONSTRUCTION.

REMOVABLE BASE IN BATHROOM TO PROVIDEREQUIRED CLEAR FLOOR AREA FOR WATERCLOSET OR BATHTUB. PROVIDE WALL MOUNTEDEND PANEL TO SUPPORT COUNTERTOP. FINISHADJACENT WALL SURFACES/CABINETS AT TIME OFINITIAL CONSTRUCTION.

SEE SHEETS A1.3 & A1.3A FOR FURTHERINFORMATION

HC1

HC2

HC3

HC4

HC5

HC6

HC7

HC8

HC9

HC10

8/

31

/2

01

6 9

:42

:11

AM

CWS

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T

13

01

W. 5

TH

ST

.A

U ST

IN, T

X 7

87

03

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.16A

UNIT A12-HC INT.ELEVATIONS

08/31/16

08/15/16

04/18/16

3/8" = 1'-0"1 UNIT A12-HC - KITCHEN ELEVATION 1 3/8" = 1'-0"2 UNIT A12-HC - KITCHEN ELEVATION 2

3/8" = 1'-0"3 UNIT A12-HC - BATH ELEVATION 1 3/8" = 1'-0"4 UNIT A12-HC - BATH ELEVATION 2

3/8" = 1'-0"5 UNIT A12-HC - BATH ELEVATION 3 3/8" = 1'-0"6 UNIT A12-HC - BATH ELEVATION 4

3/8" = 1'-0"7 UNIT A12-HC - BATH ELEVATION 5 3/8" = 1'-0"8 UNIT A12-HC - BATH ELEVATION 6

3/8" = 1'-0"9 UNIT A12-HC - UTILITY ELEVATION 3/8" = 1'-0"10

UNIT A12-HC - A/C CLOSET & MAKE UPAIR CALC. ELEVATION

1

11

1

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 25: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

REF.

DW

REF.

DW

BALCONY

LIVING

UTIL.

BEDROOM

WIC

KITCHENBATH

DINING

DE

SK

PA

N.

1R

1S

LIN

EN

A/C& WH

1R1S

2R

2S

SS

36"X48"SHOWER

36"X60"TUB

1R1S

2R

2S

3

6

7

4

3

1

3

12

/A

3.1

73 /

A3

.17

5

/A3.174

/A

3.1

71

3

/A

3.1

71

2

/A3.1710

/A3.176

/A3.178

/A3.177

/A

3.1

79

/A

3.1

71

1

A

8' - 3" 2' - 10 1/2"

2' - 0 1/2"

1' - 10 1/2" 3' - 6" 1' - 3"

1' - 4"

1' - 6 1/2"

26' - 0"

13

' - 5

1/

2"

6' -

3 1

/2

"6

' - 0

"4

' - 5

"6

' - 0

1/

2"

16

' - 8

"1

8' -

4"

37

' - 1

0"

7' -

1"

4' -

6 1

/2

"2

' - 7

"

2' - 5" 3' - 9" 2' - 1 1/2"

0' - 5 1/2" 0' - 10"

3' - 9"

1' - 11"

1' - 10 1/2"

2' - 4"

1' - 11 1/2"

5' - 10 1/2" 5' - 0" 3' - 6"

0' - 5 1/2"

0' - 1"

0' - 3 1/2"

5' - 3"

1' -

11

1/

2"

2' -

0"

1' -

8"

2' -

3"

1' -

11

1/

2"

1' -

11

"1

' - 9

"2

' - 3

"

3' -

3 1

/2

"

1' -

2 1

/2

"

2' - 3 1/2"

SL

OP

E

1/

4"=

1'-

0"

3" SOLID BLOCKINGAT END OF

EACH RAIL(TYP)

42" GUARDRAIL(TYP)

TR

16A

BALCONY

LIVING

UTIL.

BEDROOM

WIC

KITCHEN

BATH

DINING

CVPTVP

T

C

8'-0"A.F.F.

8'-6"A.F.F.

TR

DESK

FURROUT

2742 3342

3024

3342

30" PAN. FRONT33" DB33" CAB.15" CAB. 30" OPENFOR RANGE

MICROWAVE/VENTHOOD COMBO3" FILLER

3" FILLER

TILE BACKSPLASH

17' - 7" R.O.

17' - 10 1/2"

3' -

0"

1' -

6"

3' -

6"

8' -

0"

2' -

10

"1

' - 8

"1

' - 0

"2

' - 6

"

2 1/2" FILLER

3930

3642

3618

24" CAB.

TILE BULLNOSE

3" FILLER1 1/2" FILLER

3" FILLER

3' -

6"

1' -

6"

3' -

0"

8' -

0"

0' - 3 1/2" 7' - 5 3/4" R.O.

13' - 0 1/4"

ENTRYDOOR 36" OPENFOR REF.

FURROUT

21" TRASH 36" CAB. 24" OPENFOR D.W.

1" ENDPANEL

1" ENDPANEL

3' -

0"

7' - 1"

13' - 9"

FURROUT

2' -

0"

6' -

0" 8

' - 0

"

FURROUT SHOWER HEAD @ 7'-0" A.F.F.

1

SHOWER3' - 0 3/4"

10' - 1 1/4"

3' -

5"

1' -

11

"0

' - 8

"2

' - 6

"

8' -

6"

FURROUT

1

SHOWER

SHOWERSEAT

GLASS

1' -

6"

4' -

6"

0' -

10

"0

' - 8

"2

' - 6

"

8' -

6"

3' - 0 3/4"

FURROUT

SHELF

1

TUB

GLASS

24" TB @4'-6" A.F.F.

5' - 3" 3' - 0 3/4"

12' - 1 1/4"

4' -

6"

0' -

10

"0

' - 8

"1

' - 3

"1

' - 3

"

8' -

6"

FURROUT

SHELF

11

GLASS ABOVE LOW WALL

SHOWER TUB

0' - 5 1/2"4' - 1 1/4"

9' - 8"

4' -

6"

0' -

10

"0

' - 8

"2

' - 6

"

8' -

6"

1' -

6"

1' -

5"

0' -

6"

1' -

3" 3

' - 2

"

FURROUT

SHELF

30" VB 12"DB 30" VB

MIRROR

4" BACKSPLASH

1

1

3

1 1/2" FILLERTUB

3' - 0 3/4" 1' - 6 1/2" 1' - 4"

12' - 1 1/4"4

' - 2

"2

' - 1

0"

7' -

0"

1' -

0"

2' -

7"

1' -

3"

1' -

3"

0' -

8"

1' -

11

"3

' - 5

"

8' -

6"

FURROUT

1 1/2" FILLER

FURROUT

3' - 4 1/4"

3' - 7 3/4"

36" LIN. FRONT

WASHER/DRYER

3' - 11 1/4"

UTIL. 1"X34" = 34 SQ.IN. FREE AREA

24"X83" = 1992 SQ.IN. FREE AREA

A/C CLOSET

RETURN AIRVENT

UNDERCUTDOOR 1"

FREE AREA REQUIREMENTS

TOTAL FREE AREA REQUIRED = 100 SQ.IN.TOTAL FREE AREA PROVIDED = 2026 SQ.IN.

17' - 1 1/2"

FLOOR FINISHES

VP - VINYL PLANK

C - CARPET

T - TILE

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:42

:12

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.17

UNIT A13 FLOOR PLANS & INT.ELEVATIONS

08/31/16

08/15/16

1/4" = 1'-0"1 UNIT A13 FLOOR PLAN 1/4" = 1'-0"2 UNIT A13 FINISH FLOOR PLAN

3/8" = 1'-0"3 UNIT A13 - KITCHEN ELEVATION 1 3/8" = 1'-0"4 UNIT A13 - KITCHEN ELEVATION 2

3/8" = 1'-0"5 UNIT A13 - KITCHEN ELEVATION 3 3/8" = 1'-0"6 UNIT A13 - BATH ELEVATION 1

3/8" = 1'-0"7 UNIT A13 - BATH ELEVATION 2 3/8" = 1'-0"8 UNIT A13 - BATH ELEVATION 3

3/8" = 1'-0"9 UNIT A13 - BATH ELEVATION 4 3/8" = 1'-0"10 UNIT A13 - BATH ELEVATION 5

3/8" = 1'-0"11 UNIT A13 - BATH ELEVATION 6

3/8" = 1'-0"12 UNIT A13 - UTILITY ELEVATION 3/8" = 1'-0"13

UNIT A13 - A/C CLOSET & MAKE UP AIRCALC. ELEVATION

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 26: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

REF.

DW

DN

UP7 6 5 4 3 2 1

17

16

15

14

13

12

11

10

9

8

21201918

REF.

DW

DN

UP

BALCONY

UTIL.

BEDROOM

WIC

KITCHEN

BATH

DINING

DE

SK

PA

N.

1R

1S

LIN

EN

A/C& WH

1R1S

2R

2S

SS

34"X48"SHOWER

36"X60"TUB

1R1S

2R

2S

CHASE

3

6

7

4

12

3

3

1

/A

3.1

7B

1 /A

3.1

7B

2

/A3.17B3

/A

3.1

7B

11

/A

3.1

7B

10

/A3.17B4

/A3.17B5

/A3.17B6

/A3.17B7

/A

3.1

7B

8

/A

3.1

7B

9

26' - 0"

6' -

3 1

/2

"6

' - 0

"4

' - 5

"6

' - 0

1/

2"

3' -

7 1

/2

"1

1' -

10

1/

2"

18

' - 6

" 7' -

1"

3' -

7"

3' -

6 1

/2

"

5' - 10" 5' - 0" 3' - 6"

0' - 5 1/2"

0' - 1"

0' - 3 1/2"

5' - 3"

1' - 11 1/2"

0' - 4"

1' - 5 1/2"

2' - 4"

8' - 3" 2' - 10 1/2"

2' - 0 1/2"

1' - 10 1/2" 3' - 6" 1' - 3"

1' - 4"

1' - 6 1/2"

2' -

0 1

/2

"

1' -

0 1

/2

"

2' -

0"

1' -

8"

2' -

3"

1' -

11

1/

2"

2' -

0"

1' -

8"

2' -

3"

3' -

3 1

/2

"

1' -

2 1

/2

"

6' - 2" 2' - 1 1/2"

0' - 5 1/2"

4' - 7"

4' - 3 1/2"

1' - 10 1/2"

1' - 11"

SL

OP

E

1/

4"=

1'-

0"

3" SOLID BLOCKINGAT END OF EACH

RAIL(TYP)

42" GUARDRAIL(TYP)

37

' - 1

0"

TR

16

A

1/2 BATH

LIVING

WETBAR

3

2' -

10

"2

' - 1

1"

2' -

4"

1' -

9"

6' -

10

"

15

' - 2

1/

2"

9' - 1 1/2"

26' - 0"

/A3.17B12/

A3

.17

B1

3

0' - 3 1/2"

1' - 6 1/2" 2' - 10" 2' - 1"

0' - 3 1/2" 0' - 7"

3' - 3 1/2" 9' - 7" 4' - 6 1/2" 0' - 6"

/A

3.1

7B

14

PATIO

16 A

BALCONY

UTIL.

BEDROOM

WIC

KITCHEN

BATH

DINING

CVPTVP

T

C

8'-0"A.F.F.

8'-6"A.F.F.

TR

1/2 BATH

LIVING

WETBAR

T VP

8'-0"A.F.F.

8'-6"A.F.F.

SLOPE GYP.BD. CLG.

UNDERNEATHSTAIRS UNTIL

8'-6" A.F.F.9'-6"A.F.F.TYP.

PATIO

FLOOR FINISHES

VP - VINYL PLANK

C - CARPET

T - TILE

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:42

:13

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.17A

UNIT A13.2 FLOOR PLANS

08/31/16

08/15/16

1/4" = 1'-0"1 UNIT A13.2 FLOOR PLAN

1/4" = 1'-0"2 UNIT A13.1 FLOOR PLAN

1/4" = 1'-0"3 UNIT A13.2 FINISH FLOOR PLAN

1/4" = 1'-0"4 UNIT A13.1 FINISH FLOOR PLAN

1 1

1

1

No. Revision Date

1 REV 1 Date 1

Page 27: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

2742 3342

3024

3342

30" PAN. FRONT33" DB33" CAB.15" CAB. DESK

FURROUT

30" OPENFOR RANGE

MICROWAVE/VENTHOOD COMBO3" FILLER

3" FILLER

TILE BACKSPLASH

3' -

0"

1' -

6"

3' -

6"

8' -

0"

2' -

10

"

0' -

2"

1' -

6"

1' -

0"

2' -

6"

17' - 7" R.O.

18' - 0 1/2"

2 1/2" FILLER

24" OPENFOR D.W.

1" ENDPANEL

1" ENDPANEL

3' -

0"

7' - 1"

13' - 9"

36" CAB.21" TRASH

2' -

0"

6' -

0" 8

' - 0

"

FURROUT

TILE BULLNOSE

3" FILLER1 1/2" FILLER

3" FILLERENTRYDOOR 36" OPENFOR REF.

3618

3642

24" CAB.

0' - 3 1/2" 7' - 5 3/4"

13' - 0 1/4"

3' -

6"

1' -

6"

3' -

0"

8' -

0"

FURROUT

30" VB 12"DB 30" VB

4" BACKSPLASH

1

1

3

1 1/2" FILLERTUB

MIRROR

3' - 0 3/4" 1' - 6 1/2"1' - 4"

12' - 1 1/4"

3' -

5"

1' -

11

"

0' -

8"

1' -

3"

1' -

3"

8' -

6"

1' -

0"

2' -

7"

4' -

2"

2' -

10

"

7' -

0"

FURROUT

FURRDOWN SHOWER HEAD @ 7'-0" A.F.F.

1

SHOWER3' - 0 3/4"

10' - 1 1/4"

3' -

5"

1' -

11

"0

' - 8

"2

' - 6

"

8' -

6"

7' -

0"

FURROUT

1

TUB

GLASS

24" TB @4'-6" A.F.F.

5' - 3" 3' - 0 3/4"

12' - 1 1/4"

4' -

6"

0' -

10

"0

' - 8

"1

' - 3

"1

' - 3

"

8' -

6"

FURROUT

SHELF

1

SHOWER

SHOWERSEAT

GLASS

4' -

6"

0' -

10

"0

' - 8

"2

' - 6

"

8' -

6"

3' - 0 3/4"

FURROUT

1' -

6"

SHELF

11

GLASS ABOVE LOW WALL

SHOWER TUB

4' -

6"

0' -

10

"0

' - 8

"2

' - 6

"

8' -

6"

0' - 5 1/2"4' - 1 1/4"

9' - 8"

1' -

5"

0' -

6"

1' -

3" 3

' - 2

"

1' -

6"

FURROUT

SHELF

1 1/2" FILLER

FURRDOWN

36" LIN. FRONT

3' - 4 1/4"

3' - 7 3/4"

7' -

0"

WASHER/DRYER

3' - 11 1/4"

UTIL. 1"X34" = 34 SQ.IN. FREE AREA

24"X83" = 1992 SQ.IN. FREE AREA

A/C CLOSET

RETURN AIRVENT

UNDERCUTDOOR 1"

FREE AREA REQUIREMENTS

TOTAL FREE AREA REQUIRED = 100 SQ.IN.TOTAL FREE AREA PROVIDED = 2026 SQ.IN.

18' - 2"

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

36" VB

1' -

6"

2' -

6"

1' -

3"

0' -

8"

2' -

7"

8' -

6" 2430 MIRROR

2' -

10

"

6' - 1 3/4"

7' - 0"

4" BACK-SPLASH

11

2' -

7"

0' -

8"

1' -

3"

2' -

6"

1' -

6"

8' -

6"

3' - 10" 0' - 10"

6' - 6 3/4"

2442 2442

1 1/2" FILLER1 1/2" FILLER

1 1/2" FILLER 24"BEVERAGE

COOLER

TILEBACKSPLASH

FURROUTOPENSHELVING

1 1/2" FILLER

(GLASSFRONT)

(GLASSFRONT)

27" CAB. 24" CAB.

3' -

0"

1' -

6"

3' -

6"

8' -

0"

6' - 6 3/4" R.O.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:42

:15

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.17B

UNIT A13.2 INT. ELEVATIONS

08/15/16

08/15/16

3/8" = 1'-0"1 UNIT A13.2 - KITCHEN ELEVATION 1 3/8" = 1'-0"2 UNIT A13.2 - KITCHEN ELEVATION 2

3/8" = 1'-0"3 UNIT A13.2 - KITCHEN ELEVATION 3 3/8" = 1'-0"4 UNIT A13.2 - BATH ELEVATION 1

3/8" = 1'-0"5 UNIT A13.2 - BATH ELEVATION 2 3/8" = 1'-0"6 UNIT A13.2 - BATH ELEVATION 3

3/8" = 1'-0"7 UNIT A13.2 - BATH ELEVATION 4 3/8" = 1'-0"8 UNIT A13.2 - BATH ELEVATION 5

3/8" = 1'-0"9 UNIT A13.2 - BATH ELEVATION 6

3/8" = 1'-0"10 UNIT A13.2 - UTILITY ELEVATION 3/8" = 1'-0"11

UNIT A13.2 - A/C CLOSET & MAKE UP AIRCALC. ELEVATION

3/8" = 1'-0"12 UNIT A13.2 1/2 BATH ELEVATION 1 3/8" = 1'-0"13 UNIT A13.2 1/2 BATH ELEVATION 2

11

1

1

1

1

3/8" = 1'-0"14 UNIT A13.2 - WET BAR ELEVATION

1

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 28: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

REF.

DW

REF.

DW

SHELF

SHELF

KITCHEN

BA

LC

ON

Y

UTILITYROOM

DINING

LIVINGWIC

BEDROOM

BATH

1R1S

2R

2S

1R1S

2R2S

DESK

AC& WH

LIN

EN

PA

NT

RY

1R1S

36"X60"TUB

36"X48"SHOWER

/A3.18 3

/A3.18 5

/A

3.1

84

/A

3.1

81

2

/A3.18 6/A3.18 8

/A3.18 9

/A3.18 11

/A

3.1

81

0/A

3.1

87

/A3.18

13

/A3.18

14

1

5

3

7

6

3 1218

S1

S11

2' - 4" 3' - 5 1/2" 1' - 11" 4' - 1 1/2" 7' - 8 1/2"

135.00°

1' -

2 1

/2

"5

' - 6

"5

' - 5

" 1' -

6 1

/2

"

1' -

10

1/

2"

3' -

2"

30

' - 4

1/

2"

6' - 11" 11' - 1" 0' - 11 1/2" 17' - 0 1/2"

7' - 1"5' - 9"2' - 4 1/2"

6' -

9"

2' -

1 1

/2

"

0' -

5 1

/2

"

0' -

10

"

7' -

0 1

/2

"3

' - 1

1/

2"

5' -

11

"1

' - 3

1/

2"

8' -

8 1

/2

"1

' - 1

1 1

/2

"

2' -

4 1

/2

"

13

5.0

1' - 11 1/2"

2' - 1 1/2" 3' - 4" 1' - 11 1/2"

2' - 4"

2' - 8 1/2"1' - 5 1/2"

0' - 9 1/2"

2' - 3 1/2"1' - 11"3' - 4"

1' -

5"

3' -

6"

0' -

8"

1' -

0 1

/2

"

4' -

5"

1' - 1

1 1/2"

6' - 9

"

1' - 9

1/2"

2' - 4 1/2"

3' - 9

"

3' - 8

"

5' - 9

1/2"

0' - 5

1/2"

S12

A

3" SOLID BLOCKINGAT END OF EACHRAIL(TYP)

42" GUARDRAIL(TYP)

36' - 9 1/2"

A

8' -

0 1

/4

"5

' - 7

1/

4"

0' -

6 1

/2

"

4' -

0 1

/4

"4

' - 2

"

3

2' - 10"0' - 10"

TR

NOTE: SEE WALLSECTIONS @ BALCONYAS DETAILING VARIESPER FLOOR

SS

KITCHEN

BA

LC

ON

Y

UTILITYROOM

DINING

LIVING

WIC

BEDROOM

BATH

T

C

VP

T

T

VP

VPC

8'-6"A.F.F.

8'-6"A.F.F.

7'-0"A.F.F.

8'-0"A.F.F.

TR

36" CAB. 21" TRASH24" OPENFOR D.W.

1" ENDPANEL

1" ENDPANEL

3' -

6"

1' -

6"

3' -

0"

8' -

0"

3' - 5" 7' - 1"

OPEN TOLIVING

2

FURROUT

3' -

0"

12' - 6 3/4"

2 1/2" FILLER3" FILLER

3" FILLER 21" CAB. 33" DB

33423342

30" PAN. FRONT

TILE BACKSPLASH

3' -

6"

1' -

6"

3' -

0"

8' -

0"

9' - 6 3/4" R.O.

9' - 10 1/4"

FURROUT

3" FILLERMICROWAVE/VENTHOOD COMBO1 1/2" FILLER

3" FILLER

TILE BULLNOSE

30" OPENFOR RANGE

36" OPENFOR REF.

3618

3642

3024

3642 3642

24" CAB.36" CAB.36" CAB.

3' -

0"

1' -

6"

3' -

6"

8' -

0"

FURROUT

1

SHOWER HEAD @ 7'-0" A.F.F.

SHOWER

FURROUT

3' - 0 3/4"

8' - 11 1/2"

3' -

5"

1' -

11

"0

' - 8

"2

' - 6

"

8' -

6"

7' -

0"

FURROUT

30" LIN. FRONT

11

TUB

1 1/2" FILLER

FURROUT

0' - 3 1/2"1' - 6 1/2"

1' - 7"

0' - 3 1/2"

2' - 10 1/4"

11' - 8"

7' -

0"

1' -

0"

2' -

7"

5' -

4"

1' -

5"

0' -

6"

1' -

3"

8' -

6"

FURROUT

24" TB @4'-0" A.F.F.

1

SHOWER2' - 10 1/4" 2' - 10 3/4"

8' - 9 1/2"

5' -

4"

0' -

8"

2' -

6"

8' -

6"

1' -

6"

FURROUT

SHOWERSEAT

1

TUB

3' - 0 3/4"

5' -

4"

0' -

8"

1' -

3"

1' -

3"

8' -

6"

FURROUT

30" VB 12"DB 30" VB 1 1/2"FILLER

1 1/2"FILLER

SHOWER

1

MIRROR

4" BACKSPLASH

1' -

6"

2' -

6"

0' -

8"

5' -

4"

8' -

6"

0' - 3 1/2" 6' - 4 1/4" R.O. 0' - 11"

11' - 8"

2' -

10

"4

' - 2

"

7' -

0"

WALL IS FLUSHWITH CABINET

FURROUT

1

TUB3' - 10 3/4" 3' - 0 3/4"

8' - 9 1/2"

3' -

5"

1' -

11

"0

' - 8

"2

' - 6

"

8' -

6"

2' -

10

"

FURROUT

WASHER & DRYER

6' - 5 1/4"

4' -

8"

1' -

2"

5' -

10

"

UTIL. 1"X34" = 34SQ.IN. FREEAREA

24"X83" = 1992SQ.IN. FREEAREA

A/C CLOSET

RETURN AIRVENT

UNDERCUTDOOR 1"

FREE AREA REQUIREMENTS

TOTAL FREE AREA REQUIRED = 100 SQ.IN.TOTAL FREE AREA PROVIDED = 2026 SQ.IN.

DESK

3' - 4 1/4"

2' -

6"

1' -

0"

2' -

0"

2' -

6"

8' -

0"

FLOOR FINISHES

VP - VINYL PLANK

C - CARPET

T - TILE

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:42

:16

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.18

UNIT A14 FLOOR PLANS & INT.ELEVATIONS

08/31/16

08/15/16

1/4" = 1'-0"1 UNIT A14 FLOOR PLAN 1/4" = 1'-0"2 UNIT A14 FINISH FLOOR PLAN

3/8" = 1'-0"3 UNIT A14 - KITCHEN ELEVATION 1 3/8" = 1'-0"4 UNIT A14 - KITCHEN ELEVATION 2

3/8" = 1'-0"5 UNIT A14 - KITCHEN ELEVATION 3 3/8" = 1'-0"6 UNIT A14 - BATH ELEVATION 1

3/8" = 1'-0"7 UNIT A14 - BATH ELEVATION 2 3/8" = 1'-0"8 UNIT A14 - BATH ELEVATION 3

3/8" = 1'-0"9 UNIT A14 - BATH ELEVATION 4 3/8" = 1'-0"10 UNIT A14 - BATH ELEVATION 5

3/8" = 1'-0"11 UNIT A14 - BATH ELEVATION 6

3/8" = 1'-0"12 UNIT A14 - UTILITY ELEVATION 3/8" = 1'-0"13

UNIT A14 - A/C CLOSET & MAKE UP AIRCALC. ELEVATION

3/8" = 1'-0"14 UNIT A14 - DESK ELEVATION

1

1

1

1

1

1

1

1

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 29: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

REF

.

DW

REF

.

DW

SHELF

SHELF

BALCONY

WIC

BEDROOM 1

BATH 1

KITCHEN

LIVING

BEDROOM 2

BATH 2

UTIL.

WIC

A

2A

2

2

6

5

13

1

2

2

2

2R

2S

1R1S

A/C& WH

LIN

EN

36"X48"SHOWER PAN.

1R1SLINEN

36"X60"TUB/

SHOWER

2R2S

1R

1S

/A

3.1

98

/A

3.1

96

/A3.197

/A

3.1

93

/A

3.1

95

/A3.194

/A

3.1

91

3

/A

3.1

91

4

/A

3.1

91

2

/A

3.1

91

0

/A3.199

/A3.1911

6' - 3 1/2" 1' - 3"

1' - 8 1/2"

2' - 10 1/2"

1' - 10 1/2"

4' - 1" 4' - 9 1/2" 2' - 7 1/2"

1' - 6 1/2"

1' - 6 1/2"

0' - 3 1/2"35' - 6 1/2"

3' -

6"

13

' - 9

"

9' -

4 1

/2

"5

' - 4

1/

2"

12

' - 7

1/

2"

28

' - 5

1/

2"

6' - 5" 6' - 3" 5' - 8" 2' - 1" 3' - 4 1/2"

1' - 0"

5' - 3"

1' -

2 1

/2

"

3' -

2 1

/2

"3

' - 4

"4

' - 1

1/

2"

10

' - 9

"3

' - 6

1/

2"

2' - 0 1/2"

2' - 4"

2' - 0 1/2"

2' - 0 1/2" 3' - 4"

7' - 2 1/2" 2' - 11"

1' -

10

1/

2"

2' -

9 1

/2

"2

' - 5

"3

' - 6

"2

' - 6

"

2' -

9"

3' -

6"

5' -

4"

0' -

3 1

/2

"

0' -

10

"

6' - 5" 2' - 1 1/2"

0' - 5 1/2"0' - 10"

SL

OP

E

1/

4"=

1'-

0"

3" SOLID BLOCKINGAT END OF EACHRAIL(TYP)

42" GUARDRAIL(TYP)48" GUARDRAIL ATCOURTYARD LEVEL 2

SS

5' -

0 1

/2

"3

' - 1

1 1

/2

"4

' - 1

1 1

/2

"

2' - 1

"2' -

0"

16

BALCONY

WIC

BEDROOM 1

BATH 1

KITCHEN

LIVING

BEDROOM 2

BATH 2

UTIL.

WICVP

C

VP

T

C

T

C

VP

8'-6"A.F.F.

8'-0"A.F.F.

8'-6"A.F.F.

VENTHOOD 1 1/2" FILLER3" FILLER

3" FILLER 30" OPENFOR RANGE

36" OPENFOR REF.

1242 3042

3024

3342

3618

33" CAB.30" CAB.

TILEBULLNOSE

5' -

2"

2' -

10

"

8' -

0"

A/C CLOSET UNDERCUTDOOR 1"

RETURNAIR VENT

13' - 2 3/4" R.O.

HC3HC5HC2

COUNTERTOPMICROWAVE

FURROUT

1 1/2" FILLER 3" FILLER

3" FILLER

3042

24" PAN. FRONT 18" CAB.ENTRY DOOR COAT CLOSET

5' - 11 3/4" R.O.3' - 0 3/4"

14' - 1 3/4"

2' -

10

"1

' - 8

"0

' - 3

3/

4"

4' -

9 3

/4

"

TILEBACKSPLASH

FURROUT

1" ENDPANEL

HC12' -

10

"

0' - 10"

0' - 3 1/2"

5' - 4 1/4" 3' - 6 1/4"

12' - 3 1/4"

24" OPENFOR D.W.

36" CAB.

8' -

0"

1 1/2" FILLER

FURROUT

HC78' -

6"

SHOWER

3' -

5"

1' -

11

"0

' - 8

"2

' - 6

"

24" TB @4'-6" A.F.F.

FURROUT SHOWER HEAD @ 7'-0" A.F.F.

2' - 10 3/4"

HC7

SHOWER

5' - 9 1/4"

FURROUT

1' -

9"

1' -

5"

5' -

4"

8' -

6"

0' - 10"4' - 1 1/4"

1' -

6"HC6

SHOWER

8' -

6"

FURROUT

HC7HC7

15" DB30" VB15" DB24" LIN. FRONT

MIRROR

SHELVES

4" BACKSPLASH

0' - 3 1/2" 7' - 2 1/4" 1' - 5 1/2" 1' - 6 1/2" 3' - 0 3/4"

16' - 6 1/4"

5' -

4"

0' -

8"

2' -

6"

1' -

0"

2' -

7"

2' -

10

"4

' - 2

"

7' -

0"

1' -

6"

SHOWERSEAT

MIRROR

24" LIN. FRONT15" DB33" VB

4" BACK-SPLASH

HC7

1 1/2" FILLER

2' -

7"

0' -

8"

2' -

10

"4

' - 2

"

7' -

0"

1' - 6 1/2" 2' - 9 1/2"

10' - 6"

HC6

15" DB

HC7

TUB/SHOWER

5' -

4"

0' -

8"

1' -

3"

1' -

3"

8' -

6"

3' - 0 3/4"

FURROUT

TUB/SHOWER5' - 1 1/4"0' - 3 1/2"

5' -

4"

1' -

5"

0' -

6"

1' -

3"

8' -

6"

10' - 6"

HC7

FURROUT

HC7

HC7

HC8

SHOWER HEAD @ 7'-0" A.F.F.

24" TB @4'-0" A.F.F.

TUB/SHOWER

3' - 0 3/4"

8' - 7 1/4"

3' -

5"

1' -

11

"

0' -

8"

1' -

3"

1' -

3"

8' -

6"

3' - 10" 0' - 10"

0' -

8"

2' -

7"

FURROUT

WASHER & DRYER

4' -

8"

1' -

2"

5' -

10

"

7' - 0 1/4"

UTIL. 1"X60" = 60 SQ.IN. FREE AREA

2 X (22"X83") =3652 SQ.IN.FREE AREA

FREE AREA REQUIREMENTS

TOTAL FREE AREA REQUIRED = 100 SQ.IN.TOTAL FREE AREA PROVIDED = 3712 SQ.IN.

UNDERCUT DOOR 1"

6' - 6 3/4"

FLOOR FINISHES

VP - VINYL PLANK

C - CARPET

T - TILE

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2-A3.2A FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

ADAPTABLE ELEMENTS FOR TYPE A UNITSPER ICC/ANSI A117.1-2003 SEE SHEETS A1.4-A1.4F

REMOVABLE SINK BASE CABINET IN KITCHEN W/REAR DRAIN SINK. PROVIDE PANEL TO COVERPIPING, GARBAGE DISPOSAL, ETC., OR WRAPEXPOSED PIPING, IF CABINET IS REMOVED.EXTENDFLOORING UNDER CABINET & FINISH ADJACENTWALL SURFACES/CABINETS AT TIME OF INITIALCONSTRUCTION.

REMOVABLE BASE CABINET TO KITCHEN TOPROVIDE MIN. 30" WORK SPACE. FINISHADJACENTWALL SURFACES/CABINETS AT TIME OF INITIALCONSTRUCTION.

OVENS, RANGES, AND OTHER COOKING DEVICESSHALL HAVE UPFRONT CONTROLS.

DOOR PULLS OR HANDLES FOR WALL CABINETSSHALL BE MOUNTED AS CLOSE TO THE BOTTOMOF CABINET DOORS AS POSSIBLE. DOOR PULLSORHANDLES FOR BASE CABINETS SHALL BE MOUNTEDAS CLOSE TO THE TOP OF CABINET DOORS ASPOSSIBLE.

REFRIGERATOR/FREEZERS MUST BE OF THEVERITCAL SIDE-BY-SIDE TYPE; OR OF THEVERTICAL OVER-AND-UNDER TYPE WITH ATLEAST 50% OF THE FREEZER SPACE BELOW 54°ABOVE THE FLOOR AND 100% OF THEREFRIGERATOR SPACE AND CONTROLS BELOW 54".

REMOVABLE SINK BASE CABINET IN BATHROOM.PROVIDE PANEL TO COVER PIPING, OR WRAPEXPOSED PIPING IF CABINET IS REMOVED.EXTENDFLOORING UNDER CABINET AND FINISH ADJACENTWALL SURFACES/CABINETS AT TIME OF INITIALCONSTRUCTION.

GRAB BARS INSTALLED AT REQUEST OF FUTURETENANT, BUT BLOCKING MUST BE PROVIDED AT TIMEOF INITIAL CONSTRUCTION.

PROVIDE HANDHELD SHOWERHEAD, HOSE &VERTICAL BAR.

FOLDING SHOWER SEAT INSTALLED AT REQUESTOF FUTURE TENANT, BUT BLOCKING MUST BEPROVIDED AT TIME OF INITIAL CONSTRUCTION.

REMOVABLE BASE IN BATHROOM TO PROVIDEREQUIRED CLEAR FLOOR AREA FOR WATERCLOSET OR BATHTUB. PROVIDE WALL MOUNTEDEND PANEL TO SUPPORT COUNTERTOP. FINISHADJACENT WALL SURFACES/CABINETS AT TIME OFINITIAL CONSTRUCTION.

SEE SHEETS A1.3 & A1.3A FOR FURTHERINFORMATION

HC1

HC2

HC3

HC4

HC5

HC6

HC7

HC8

HC9

HC10

8/

31

/2

01

6 9

:42

:18

AM

CWS

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T

13

01

W. 5

TH

ST

.A

U ST

IN, T

X 7

87

03

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.19

UNIT B1-HC FLOOR PLANS &INT. ELEVATIONS

08/31/16

08/15/16

03/21/16

1/4" = 1'-0"1 UNIT B1-HC FLOOR PLAN 1/4" = 1'-0"2 UNIT B1-HC FINISH FLOOR PLAN

3/8" = 1'-0"3

UNIT B1-HC - KITCHEN ELEVATION 1 &A/C CLOSET ELEVATION

3/8" = 1'-0"4 UNIT B1-HC - KITCHEN ELEVATION 2 3/8" = 1'-0"5 UNIT B1-HC - KITCHEN ELEVATION 3

3/8" = 1'-0"6 UNIT B1-HC - BATH 1 ELEVATION 1

3/8" = 1'-0"7 UNIT B1-HC - BATH 1 ELEVATION 2 3/8" = 1'-0"8 UNIT B1-HC - BATH 1 ELEVATION 3

3/8" = 1'-0"9 UNIT B1-HC - BATH 2 ELEVATION 1 3/8" = 1'-0"10 UNIT B1-HC - BATH 2 ELEVATION 2

3/8" = 1'-0"11 UNIT B1-HC - BATH 2 ELEVATION 3 3/8" = 1'-0"12 UNIT B1-HC - BATH 2 ELEVATION 4

3/8" = 1'-0"13 UNIT B1-HC - UTILITY ELEVATION 3/8" = 1'-0"14

UNIT B1-HC - MAKE UP AIR CALC.ELEVATION

1

11

1

1

1

1

1

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 30: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

REF

.

DW

REF

.

DW

SHELF

SHELF

BALCONY

BEDROOM 1

BATH 1

WIC

LIVING

BEDROOM 2

WIC

BATH 2

UTIL.

KITCHEN

1R1S

1R1S

2R

2S

LINEN

36"X48"SHOWER

A/C& WH

PA

NT

RY

1R

1S

LIN.

36"X60"TUB/

SHOWER

1R1S

2R

2S

3

12

3

6

1

12

133

3 3

/A3.20 12

/A3.20 10

/A

3.2

01

1

/A3.20 13/A3.20 14

/A3.20 3/A3.20 5

/A

3.2

04

/A3.20 6

/A

3.2

07

/A3.20 8

/A

3.2

09

/A3.20 15

A

B

3' - 0 1/2"

2' - 0 1/2"

2' - 5 1/2"6' - 2 1/2"2' - 7 1/2"

1' - 4 1/2"

2' - 0"

2' - 10 1/2"

35' - 6 1/2"

2' -

10

"1

3' -

6"

6' -

11

"5

' - 1

0 1

/2

"1

' - 1

"

33

' - 3

"

13' - 9 1/2"2' - 3 1/2"

3' - 0"

1' - 3 1/2"5' - 6 1/2"0' - 0"5' - 6 1/2"

4' -

4"

10

' - 5

"1

3' -

10

"

1' -

2 1

/2

"

1' -

4 1

/2

"

3' -

8"

2' -

1 1

/2

"

0' -

5 1

/2

"0

' - 1

0"

3' -

8 1

/2

"

3' -

8 1

/2

"5

' - 1

1/

2"

5' -

2"

2' -

8"

3' -

3 1

/2

"2

' - 6

1/

2"

3' -

3 1

/2

"

2' - 4"2' - 3"4' - 3"

2' - 3"1' - 11 1/2"3' - 7"

1' - 8 1/2"

0' - 5 1/2"

1' - 6 1/2"

1' - 4"

2' - 4 1/2"

2' - 6 1/2"

1' - 9 1/2"

1' - 9 1/2"4' - 7 1/2"3' - 3 1/2"3' - 0"2' - 4"2' - 2 1/2"

5' - 4"

0' - 3 1/2"

0' - 10"

SLOPE

1/4"=1'-0"

3" SOLIDBLOCKINGAT END OF EACHRAIL(TYP)

42" GUARDRAIL(TYP)48" GUARDRAIL ATCOURTYARD LEVEL 2

TR

C 16

TEMPORARY SHAFTLINER FOR PHASING

2R

2S

SS

BALCONY

BEDROOM 1

BATH 1

WIC

LIVING

BEDROOM 2

WIC

BATH 2

UTIL.

KITCHEN

VP

C

T

C

VP

C

VP

T

8'-6"A.F.F.

8'-0"A.F.F.

8'-6"A.F.F.

7'-0"A.F.F.

TR

36" CAB.

OPEN TOLIVING

24" OPENFOR D.W.

0' - 10"

0' - 3 1/2"

5' - 4 1/4" 6' - 7 3/4"

1 1/2" FILLER

1" ENDPANEL

3' -

0"

17' - 8 1/2"

3' -

0"

1' -

6"

3' -

6"

FURROUT

33423342

33" PAN. FRONT

3618

33" DB 21" TRASH 3" FILLER

3" FILLER3 3/4" FILLER

TILE BACKSPLASH

12' - 11" R.O.

3' -

0"

1' -

6"

3' -

6"

8' -

0"

36" OPENFOR REF.

FURROUT

3042 3342

3024

3342

33" CAB.33" CAB.18" CAB.

TILE BACKSPLASH

30" OPENFOR RANGE

3" FILLER

3" FILLER MICROWAVE/VENTHOODCOMBO

1 1/2" FILLER

1 1/2"FILLER

ENTRYDOOR

3' -

6"

1' -

6"

3' -

0"

8' -

0"

0' - 3 1/2"11' - 11 3/4" R.O.

17' - 8 1/2"

FURROUT

36" LIN. FRONTSHOWER

1

SHOWERSEAT

1' -

6"

2' -

6"

0' -

8"

5' -

4"

8' -

6"

7' -

0"

3" FILLER

0' - 3" 4' - 2 1/2" 3' - 7 1/4" R.O.

11' - 1 1/4"

FURROUT

FURROUT

1

FURROUT

24" TB @4'-6" A.F.F.

7' -

0"

0' -

8"

2' -

7"

3' - 10" 0' - 10"

10' - 1 3/4"

12"DB 33" VB 12"DB

MIRROR

4" BACKSPLASH

SHOWER HEAD @ 7'-0" A.F.F.

1

1

SHOWER

0' -

8"

2' -

7"

3' -

5"

1' -

11

"0

' - 8

"2

' - 6

"

8' -

6"

2' -

10

"

0' - 3"4' - 11 1/4"1' - 4"1' - 6 1/2"

11' - 1 1/4"

FURROUT

1

2' -

10

"

4' - 1 1/4" 1' - 0"

8' - 4"

5' -

4"

0' -

8"

2' -

6"

8' -

6"

1' -

6"

SHOWER

FURROUT

TUB/SHOWER

24" TB @4'-6" A.F.F.

SHOWER HEAD @ 7'-0" A.F.F.

1

4' - 3 1/4"3' - 2 1/4"3' - 0 3/4"

14' - 6"

1' -

3"

1' -

3" 0

' - 8

"1' -

11

"3

' - 5

"

8' -

6"

FURROUT

1

5' - 1 1/4"

TUB/SHOWER

6' - 2 1/4"

5' -

4"

1' -

5"

0' -

6"

1' -

3"

8' -

6"

FURROUT

1 1

MIRROR

15" DB33" VB15" DB36" LIN. FRONT

3" FILLER

TUB/SHOWER

1' - 4 1/4" 1' - 6 1/2" 3' - 0 3/4"

14' - 6"

5' -

4"

0' -

8"

1' -

3"

1' -

3"

8' -

6"

1' -

0"

2' -

7"

4' -

2"

2' -

10

"

7' -

0" 4" BACKSPLASH

FURROUT

WASHER & DRYER

6' - 0"

1' -

2"

4' -

8"

5' -

10

"

UTIL. 1"X60" = 60 SQ.IN. FREE AREA

FREE AREA REQUIREMENTS

TOTAL FREE AREA REQUIRED = 100 SQ.IN.TOTAL FREE AREA PROVIDED = 3712 SQ.IN.

UNDERCUT DOOR 1"

2 X (22"X83") =3652 SQ.IN.FREE AREA

10' - 10 1/4"

A/C CLOSET UNDERCUTDOOR 1"

RETURNAIR VENT

FLOOR FINISHES

VP - VINYL PLANK

C - CARPET

T - TILE

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:42

:20

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.20

UNIT B2 FLOOR PLANS & INT.ELEVATIONS

08/15/16

08/15/16

1/4" = 1'-0"1 UNIT B2 FLOOR PLAN 1/4" = 1'-0"2 UNIT B2 FINISH FLOOR PLAN

3/8" = 1'-0"3 UNIT B2 - KITCHEN ELEVATION 1 3/8" = 1'-0"4 UNIT B2 - KITCHEN ELEVATION 2

3/8" = 1'-0"5 UNIT B2 - KITCHEN ELEVATION 3 3/8" = 1'-0"6 UNIT B2 - BATH 1 ELEVATION 1

3/8" = 1'-0"7 UNIT B2 - BATH 1 ELEVATION 2 3/8" = 1'-0"8 UNIT B2 - BATH 1 ELEVATION 3

3/8" = 1'-0"9 UNIT B2 - BATH 1 ELEVATION 4 3/8" = 1'-0"10 UNIT B2 - BATH 2 ELEVATION 1

3/8" = 1'-0"11 UNIT B2 - BATH 2 ELEVATION 2

3/8" = 1'-0"12 UNIT B2 - BATH 2 ELEVATION 3 3/8" = 1'-0"13 UNIT B2 - UTILITY ELEVATION

3/8" = 1'-0"14

UNIT B2 - MAKE UP AIR CALC.ELEVATION

3/8" = 1'-0"15 UNIT B2 - A/C CLOSET ELEVATION

1

1

1

1

1

1

1

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 31: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

REF

.

DW

REF

.

DW

SHELF

SHELF

BALCONY

BEDROOM 1

BATH 1

WIC

LIVING

BEDROOM 2

KITCHEN

UTIL.

WIC

BATH

1R1S

1R1S

2R

2S

LINEN

36"X48"SHOWER

A/C& WH

PA

NT

RY

1R

1S

36"X60"TUB/

SHOWER

1R1S

2R

2S

/A3.20A10

/A3.20A11

/A

3.2

0A

12

/A3.20A13

/A3.20A14

/A3.20A3

/A3.20A4

/A

3.2

0A

5

/A3.20A6

/A

3.2

0A

7

/A3.20A8

/A

3.2

0A

9

/A3.20A15

LIN.

12

3

3

6 3 3

313

12

1

A

B

3' - 0 1/2"

2' - 0 1/2"

2' - 9" 5' - 11" 2' - 7 1/2"

1' - 4 1/2"

1' - 6 1/2" 3' - 4"

35' - 6 1/2"

1' -

6 1

/2

"5

' - 5

"6

' - 1

1"

13

' - 6

"2

' - 1

0"

33

' - 3

"

13

' - 1

0"

10

' - 5

"4

' - 4

"

14' - 3" 1' - 10"

3' - 0"

1' - 3 1/2" 5' - 6 1/2" 5' - 6 1/2"

1' -

2 1

/2

"

1' -

4 1

/2

"

3' -

8"

2' -

1 1

/2

"

0' -

5 1

/2

"0

' - 1

0"

3' -

8 1

/2

"

3' -

8 1

/2

"5

' - 1

1/

2"

5' -

2"

2' -

6 1

/2

"

2' - 3" 2' - 3" 3' - 3 1/2"

1' - 8 1/2"

0' - 5 1/2"

1' - 6 1/2"

1' - 4"

2' - 4 1/2"

2' - 6 1/2"

1' - 9 1/2"

1' - 9 1/2"

5' - 4"

0' - 3 1/2"

0' - 10"

3' -

3 1

/2

"2

' - 6

1/

2"

3' -

3 1

/2

"

2' - 4" 2' - 3" 4' - 3"

4' - 7 1/2" 3' - 3 1/2" 3' - 0" 2' - 4" 2' - 2 1/2"

SLOPE

1/4"=1'-0"

3" SOLID BLOCKINGAT END OF EACHRAIL(TYP)

42" GUARDRAIL(TYP)

TR

16 C

2R

2S

SSBALCONY

BEDROOM 1

BATH 1

WIC

LIVING

BEDROOM 2

KITCHEN

UTIL.WIC

BATH

VP

C

T

C

VP

C

VP

T

7'-0"A.F.F.

8'-6"A.F.F.

8'-0"A.F.F.

8'-6"A.F.F.

TR

OPEN TOLIVING

24" OPENFOR D.W.

1 1/2" FILLER

1" ENDPANEL

0' - 10"0' - 3 1/2"5' - 2 1/4"0' - 1"0' - 1"6' - 7 3/4"

17' - 8 1/2"

3' -

0"

3' -

6"

1' -

6"

3' -

0"

8' -

0"

36" CAB.

3342

3024

3342 3042

18" CAB.33" CAB.33" CAB.

TILE BACKSPLASH

30" OPENFOR RANGE

3" FILLER

3" FILLERMICROWAVE/VENTHOODCOMBO

1 1/2" FILLER

1 1/2"FILLER

ENTRYDOOR

11' - 11 3/4"0' - 3 1/2"

17' - 8 1/2"

3' -

0"

1' -

6"

3' -

6"

8' -

0"

FURROUT

3" FILLER

3" FILLER 3 3/4" FILLER

TILE BACKSPLASH

36" OPENFOR REF.

3342 3342

21" TRASH 33" DB 33" PAN. FRONT

3618

12' - 11" R.O.

3' -

6"

1' -

6"

3' -

0"

8' -

0"

FURROUT

SHOWER

1

SHOWERSEAT

3" FILLER

36" LIN. FRONT

3' - 7 1/4" R.O. 4' - 2 1/2" 0' - 3"

11' - 1 1/4"

5' -

4"

0' -

8"

2' -

6"

8' -

6"

1' -

6"

7' -

0"

FURROUT

FURROUT

1

24" TB @4'-6" A.F.F.

10' - 1 3/4"

2' -

7"

0' -

8"

0' - 10" 3' - 10"

7' -

0"

FURROUT

4" BACKSPLASH

SHOWER HEAD @ 7'-0" A.F.F.

1

1

SHOWER

3

1' - 6 1/2"1' - 4"4' - 11 1/4"0' - 3"

11' - 1 1/4"

2' -

7"

0' -

8"

2' -

6"

0' -

8"1

' - 1

1"

5' -

1"

MIRROR

2' -

10

"

12"DB 33" VB 12"DB

FURROUT

2' -

6"

0' -

8"

5' -

4"

8' -

6"

1' -

6"

2' -

10

"

1' - 0" 4' - 1 1/4"SHOWER

8' - 4"

1

FURROUT

11

3" FILLER

TUB/SHOWER

4" BACKSPLASH

3' - 0 3/4" 1' - 6 1/2" 1' - 4 1/4"

14' - 6"

2' -

10

"4

' - 2

"

7' -

0"

2' -

7"

1' -

0"

1' -

3"

1' -

3"

0' -

8"

5' -

4"

8' -

6"

15" DB 33" VB 15" DB 36" LIN. FRONT

MIRROR

FURROUT

TUB/SHOWER

24" TB @4'-6" A.F.F.

SHOWER HEAD @ 7'-0" A.F.F.

1

3' - 1 1/4"3' - 1 1/2"4' - 3 1/4"

14' - 6"

3' -

5"

1' -

11

"0

' - 8

"1

' - 3

"1

' - 3

"

8' -

6"

FURROUT

1

TUB/SHOWER

5' - 1 1/4"

6' - 2 1/4"

5' -

4"

1' -

5"

0' -

6"

1' -

3"

8' -

6"

FURROUT

WASHER & DRYER

6' - 0"

4' -

8"

1' -

2"

5' -

10

"

UTIL.1"X60" = 60 SQ.IN. FREE AREA UNDERCUT DOOR 1"

2 X (22"X83") =3652 SQ.IN.FREE AREA

FREE AREA REQUIREMENTS

TOTAL FREE AREA REQUIRED = 100 SQ.IN.TOTAL FREE AREA PROVIDED = 3712 SQ.IN.

10' - 10 1/4"

A/C CLOSETUNDERCUTDOOR 1"

RETURNAIR VENT

FLOOR FINISHES

VP - VINYL PLANK

C - CARPET

T - TILE

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

BEDROOM 1BALCONY

WIC

CORRIDOR WALL. INTERIOR ROOMDIMENSION REMAINS THE SAME

4' -

9 1

/2

"

CORRIDOR0' -

3 1

/2

"0

' - 0

1/

2"

2' -

11

"2

' - 1

0"

1R1S

2R

2S

33

' - 5

"

A1 HR

P1 HR

E1 HR

DOUBLE 2X4 WALL

WALL MUST ALIGNW/ABOVE 2

R2

SS

S

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:42

:22

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.20A

UNIT B2-A FLOOR PLANS &INT. ELEVATIONS

08/15/16

08/15/16

1/4" = 1'-0"1 UNIT B2-A FLOOR PLAN 1/4" = 1'-0"2 UNIT B2-A FINISH FLOOR PLAN

3/8" = 1'-0"3 UNIT B2-A - KITCHEN ELEVATION 1 3/8" = 1'-0"4 UNIT B2-A - KITCHEN ELEVATION 2

3/8" = 1'-0"5 UNIT B2-A - KITCHEN ELEVATION 3 3/8" = 1'-0"6 UNIT B2-A - BATH 1 ELEVATION 1

3/8" = 1'-0"7 UNIT B2-A - BATH 1 ELEVATION 2 3/8" = 1'-0"8 UNIT B2-A - BATH 1 ELEVATION 3

3/8" = 1'-0"9 UNIT B2-A - BATH 1 ELEVATION 4 3/8" = 1'-0"10 UNIT B2-A - BATH 2 ELEVATION 1

3/8" = 1'-0"11 UNIT B2-A - BATH 2 ELEVATION 2 3/8" = 1'-0"12 UNIT B2-A - BATH 2 ELEVATION 3

3/8" = 1'-0"13 UNIT B2-A - UTILITY ELEVATION 3/8" = 1'-0"14

UNIT B2-A - MAKE UP AIR CALC.ELEVATION

3/8" = 1'-0"15 UNIT B2-A - A/C CLOSET ELEVATION

1/4" = 1'-0"16

UNIT B2-A FLOOR PLAN @ CORRIDORWALL

1

1

1

1

1

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 32: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

REF.D

WREF.

DW

SHELF

SHELF

BEDROOM 2

LIVING

BEDROOM 1

WIC WIC

BATH1

BATH 2

KITCHENUTIL.

2R2S

1R

1S

1R

1S

2R2S

1R

1S

1R

1S

LIN

EN

A/C& WH

36"X60"TUB/

SHOWER1R1S

PA

N.

LIN

EN

36"X48"SHOWER

BALCONY

18

12

3

3

4

1

13

6

3

12

3

/A

3.2

11

1

/A

3.2

19

/A3.21 10

/A3.21 14

/A

3.2

11

2/

A3

.21

13

/A

3.2

15

/A

3.2

13

/A3.21 4

/A

3.2

18

/A

3.2

16

/A3.21 7

CC

AA

1' - 0"4' - 5"1' - 2"7' - 0 1/2"1' - 11 1/2"

2' - 1 1/2"

2' - 11 1/2"

2' - 0 1/2"

3' - 7 1/2"5' - 7"1' - 5 1/2"

41' - 4 1/2"

11

' - 5

1/

2"

3' -

10

1/

2"

5' -

8 1

/2

"2

' - 9

"

1' -

4"

1' -

6 1

/2

"3

' - 6

"

31

' - 2

"

6' - 0"0' - 10"3' - 1"9' - 0"3' - 1"0' - 10"6' - 0"6' - 3 1/2"

14

' - 0

"0

' - 7

"4

' - 2

"1

1' -

5 1

/2

"

12

' - 4

1/

2"

1' -

11

1/

2"

4' -

11

1/

2"

2' -

6"

1' -

5 1

/2

"

1' -

6 1

/2

"3

' - 6

"

1' -

2 1

/2

"

1' -

6 1

/2

"

4' -

1 1

/2

"7

' - 1

"

3' - 10 1/2"2' - 3"

1' - 11 1/2"

4' - 9"3' - 9"2' - 1 1/2"

0' - 5 1/2"0' - 10"

4' - 7"2' - 3"2' - 0"1' - 6"2' - 8"

1' -

11

1/

2"

3' -

1 1

/2

"3

' - 2

1/

2"

3' -

0 1

/2

"

SL

OP

E

1/

4"=

1'-

0"

42" GUARDRAIL(TYP) 3" SOLID BLOCKINGAT END OF EACH RAIL(TYP)

TR

BEDROOM 2

LIVING

BEDROOM 1

WIC WIC

BATH 1BATH 2

KITCHEN

UTIL.

BALCONY

VP

C

VPT

VP C

T

C

8'-6"A.F.F.

8'-0"A.F.F.

8'-6"A.F.F.

36" CAB. 21" TRASH24" OPENFOR D.W.

1" ENDPANEL

1" ENDPANEL

3' -

0"

7' - 1"

13' - 6"

2' -

0"

6' -

0"8

' - 0

"

FURROUT1 1/2" FILLER3" FILLER

TILEBULLNOSE

3" FILLER

3618

2742

15" CAB. 36" OPENFOR REF.

COAT CLOSET ENTRY DOOR

6' - 8 3/4" R.O. 3' - 11"

15' - 11 3/4"

3' -

6"

1' -

6"

3' -

0"

8' -

0"

FURROUT

24" PAN. FRONT

1242

3024

3042 3042

30" CAB.30" DB15" CAB. 3" FILLER

TILE BACKSPLASH

30" OPENFOR RANGE

13' - 2 3/4" R.O.

3' -

6"

1' -

6"

3' -

0"

8' -

0"

3" FILLER1 1/2" FILLER MICROWAVE/VENTHOOD COMBO

FURROUT

15" DB30" VB15" DB 24" LIN. FRONT

MIRROR

4" BACKSPLASH

SHOWER

1 1

1 1/2" FILLER

3' - 0 3/4" 1' - 6 1/2" 1' - 5 1/2"

13' - 2 3/4"

4' -

2"

2' -

10

"

7' -

0"

5' -

4"

0' -

8"

2' -

6"

8' -

6"

1' -

0"

2' -

7"

FURROUT

1' -

6"

SHOWERSEAT

1

SHOWER

4' - 1 1/4"1' - 0"

5' -

4"

0' -

8"

2' -

6"

8' -

6"

1' -

6"

FURROUT

1

SHOWER

24" TB @4'-6" A.F.F.

SHOWER HEAD @ 7'-0" A.F.F.

3' - 0 3/4"

3' -

5"

1' -

11

"0

' - 8

"2

' - 6

"

8' -

6"

11

5' -

4"

0' -

8"

1' -

3"

1' -

3"

8' -

6"

4" BACKSPLASH

1 1/2" FILLER

TUB/SHOWER

MIRROR

15" DB 36" VB 15" DB 30" LIN. FRONT

3' - 0 3/4" 1' - 6 1/2" 1' - 3 3/4"

14' - 1"

4' -

2"

2' -

10

"

7' -

0"

1' -

0"

2' -

7"

FURROUT

1

TUB/SHOWER

5' - 1 1/4"

6' - 1 1/4"

5' -

4"

1' -

5"

0' -

6"

1' -

3"

8' -

6"

FURROUT

1

TUB/SHOWER

24" TB @4'-6" A.F.F.

SHOWER HEAD @ 7'-0" A.F.F.

3' - 0 3/4"

FURROUT

3' -

5"

1' -

11

"

0' -

8"

1' -

3"

1' -

3"

8' -

6"

WASHER & DRYER

6' - 8 3/4"

4' -

8"

1' -

2"

5' -

10

"

UTIL.1"X60" = 60 SQ.IN. FREE AREA UNDERCUT DOOR 1"

FREE AREA REQUIREMENTS

TOTAL FREE AREA REQUIRED = 100 SQ.IN.TOTAL FREE AREA PROVIDED = 3712 SQ.IN.

2 X (22"X83") =3652 SQ.IN. FREE

AREA

9' - 4 3/4"

13' - 4"

A/C CLOSET UNDERCUTDOOR 1"

RETURNAIR VENT

3' - 7 1/2"

FLOOR FINISHES

VP - VINYL PLANK

C - CARPET

T - TILE

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:42

:24

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.21

UNIT B3 FLOOR PLANS & INT.ELEVATIONS

08/31/16

08/15/16

1/4" = 1'-0"1 UNIT B3 FLOOR PLAN 1/4" = 1'-0"2 UNIT B3 FINISH FLOOR PLAN

3/8" = 1'-0"3 UNIT B3 - KITCHEN ELEVATION 1 3/8" = 1'-0"4 UNIT B3 - KITCHEN ELEVATION 2

3/8" = 1'-0"5 UNIT B3 - KITCHEN ELEVATION 3 3/8" = 1'-0"6 UNIT B3 - BATH 1 ELEVATION 1

3/8" = 1'-0"7 UNIT B3 - BATH 1 ELEVATION 2 3/8" = 1'-0"8 UNIT B3 - BATH 1 ELEVATION 3

3/8" = 1'-0"9 UNIT B3 - BATH 2 ELEVATION 1 3/8" = 1'-0"10 UNIT B3 - BATH 2 ELEVATION 2

3/8" = 1'-0"11 UNIT B3 - BATH 2 ELEVATION 3 3/8" = 1'-0"12 UNIT B3 - UTILITY ELEVATION

3/8" = 1'-0"13

UNIT B3 - MAKE UP AIR CALC.ELEVATION

3/8" = 1'-0"14 UNIT B3 - A/C CLOSET ELEVATION

1

1

1

1

1

1

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 33: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

REF

.

DW

REF

.

DW

BALCONY

KITCHEN

LIVINGBEDROOM 2

WIC

BATH2

WIC

BEDROOM 1

BATH1

UTIL.

12

3

6

3

12

3

13

1

PAN.

2R2S

1R

1S

DE

SK

36"X48"SHOWER

36"X60"TUB

LINEN

1R

1S A/C

& WH

LIN

.

SS

1R

1S

1R

1S

/A3.22A 1

/A3.22A 3

/A

3.2

2A

2

/A

3.2

2A

19

/A

3.2

2A

18

/A3.22A17

/A3.22A16

/A3.22A 14

/A3.22A 12

/A

3.2

2A

13

/A

3.2

2A

15

S1

S1

3

5

/A

3.2

2A

11

/A3.22A 9

/A3.22A 7

/A

3.2

2A

4

/A

3.2

2A

5 /A

3.2

2A

6

/A

3.2

2A

8 /A

3.2

2A

10

36"X60"TUB/SHOWER

S224

3' - 1 1/2"2' - 2"

2' - 6 1/2"

1' - 2 1/2"

2' - 7"

1' - 6 1/2"

1' - 4"

2' - 3"3' - 6"4' - 5"13' - 4"

39' - 2 1/2"

2' -

3"

2' -

0"

1' -

10

"3

' - 1

0"

1' -

6 1

/2

"

3' -

4"

3' -

11

"

29

' - 7

1/

2"

6' -

6 1

/2

"6

' - 1

"

0' -

5 1

/2

"

3' -

11

"7

' - 5

1/

2"

8' -

3 1

/2

"

6' - 0 1/2"5' - 10 1/2"6' - 3 1/2"4' - 10 1/2"0' - 9 1/2"9' - 7 1/2"0' - 6"

40' - 0 1/2"

4' -

2"

1' -

11

"3

' - 6

"

3' -

3 1

/2

"

1' -

11

1/

2"

2' -

2"

2' -

1 1

/2

"3' -

7"

2' -

1 1

/2

"

0' -

5 1

/2

"

0' -

10

"

7' - 1"4' - 6 1/2"2' - 6"

4' - 1 1/2"6' - 9"

3' - 2" 3' - 5 1/2"

2' - 1 1/2"

1' - 2 1/2"

0' - 4"

4' - 1 1/2"

3' -

10

"1

' - 1

1 1

/2

"1

2' -

5"

4' - 1

1/2"

135.00°

1' - 7 1/2"2' - 3 1/2"

1' - 11 1/2"

2' - 3"

2' -

7"

1' -

5 1

/2

"

2' - 7 1/2"

33

' - 2

1/

2"

A

SL

OP

E

1/

4"=

1'-

0"

3" SOLID BLOCKINGAT END OF EACHRAIL(TYP)

42" GUARDRAIL(TYP)

A

3

2' - 0 1/2"

5' - 3"

TR

2R2S SS 2R2S2R2S

BALCONY

KITCHEN

LIVING

BEDROOM 2

WIC

BATH 2

WIC

BEDROOM 1

BATH 1

UTIL.

T

C

C VP

C T

VPT

VP C8'-0"A.F.F.

8'-6"A.F.F.

8'-6"A.F.F.

7'-0"A.F.F.

TR

FLOOR FINISHES

VP - VINYL PLANK

C - CARPET

T - TILE

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:42

:25

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.22

UNIT B4 FLOOR PLANS

08/15/16

08/15/16

1/4" = 1'-0"1 UNIT B4 FLOOR PLAN 1/4" = 1'-0"2 UNIT B4 FINISH FLOOR PLAN

1

1

1

1

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 34: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

SHELF

SHELF

36" CAB. 21" TRASH24" OPENFOR D.W.

1" ENDPANEL

1" ENDPANEL

7' - 1"

13' - 9"

3' -

0"

6' -

0"

2' -

0"

8' -

0"

FURROUT

3618

3042

18" CAB.

4" FILLER3" FILLER

3" FILLER 36" OPENFOR REF.

TILEBULLNOSE

3' -

6"

1' -

6"

3' -

0"

7' - 0" R.O.

8' -

0"

FURROUTFURROUT2 1/2" FILLER

3" FILLER

TILE BACKSPLASH

30" PAN. FRONT

3342

3024

36421242

36" CAB.33" DB 30" OPENFOR RANGE

13' - 4 3/4" R.O.

3' -

6"

1' -

6"

3' -

0"

8' -

0"

FURROUT

MICROWAVE/VENTHOODCOMBO

3" FILLERSHOWER HEAD @ 7'-0" A.F.F.

SHOWER

FURRDOWN

3' - 0 3/4"

8' - 8"

3' -

5"

1' -

11

"0

' - 8

"2

' - 6

"

8' -

6"

7' -

0" 1

FURROUT

1

SHOWER

SHOWERSEAT

GLASS

3' - 0 3/4"

2' -

6"

0' -

8"

0' -

10

"4

' - 6

"

8' -

6"

1' -

6"

FURROUT

SHELF

1

TUB

GLASS

3' - 0 3/4"

4' -

6"

0' -

10

"0

' - 8

"1

' - 3

"1

' - 3

"

8' -

6"

FURROUT

SHELF

11

GLASS ABOVE LOW WALL

SHOWER TUB

4' - 1 1/4" 0' - 5 1/2" 5' - 1 1/4"

13' - 0 3/4"

4' -

6"

0' -

10

"0

' - 8

"2

' - 6

"

8' -

6"

1' -

5"

0' -

6"

1' -

3" 3

' - 2

"

FURROUT

1' -

6"

SHELF

TUB

1

3' - 0 3/4"

1' -

3"

1' -

3" 0

' - 8

"1' -

11

"3

' - 5

"

8' -

6"

FURROUT

30" VB12"DB 12"DB30" VB 24" LIN. FRONT

4" BACKSPLASH

1

MIRROR

1 1/2" FILLER

1' - 6 1/2"1' - 4"

13' - 0 3/4"4

' - 2

"2

' - 1

0"

7' -

0"

2' -

7"

0' -

8"

12"DB

1

24" TB @4'-6" A.F.F.

2' -

7"

0' -

8"

3' - 10" 0' - 10"

5' - 7 1/4"

1

TUB/SHOWER

5' -

4"

1' -

5"

0' -

6"

1' -

3"

8' -

6"

5' - 1 1/4"

7' - 2 1/2"

FURROUT

TUB/SHOWER

5' -

4"

0' -

8"

1' -

3"

1' -

3"

8' -

6"

3' - 0 3/4"

1

FURROUT

30" VB12"DB

MIRROR

4" BACK-SPLASH

1 1/2" FILLER 1 1/2" FILLER

3' - 10 1/4" R.O.

4' -

2"

2' -

10

"

7' -

0"

SHOWER HEAD @ 7'-0" A.F.F.

2' -

10

"

2' -

7"

1' -

0"

1' -

3"

1' -

3" 0

' - 8

"1' -

11

"3

' - 5

"

8' -

6"

1

1

1' - 6 1/2"3' - 0 3/4"

10' - 3"

FURROUT

24" TB @4'-6" A.F.F.

30" LIN. FRONT

1" FILLER

2' - 9 1/4" R.O.

3' - 0 3/4"

7' -

0"

FURROUT

WASHER & DRYER

6' - 4"

4' -

8"

1' -

2"

5' -

10

"

UTIL.1"X60" = 60 SQ.IN. FREE AREA UNDERCUT DOOR 1"

FREE AREA REQUIREMENTS

TOTAL FREE AREA REQUIRED = 100 SQ.IN.TOTAL FREE AREA PROVIDED = 3712 SQ.IN.

2 X (22"X83") =3652 SQ.IN.FREE AREA

8' - 9 1/4"

A/C CLOSET UNDERCUTDOOR 1"

RETURNAIR VENT

5' - 4"

DESK

3' - 2" R.O.

2' -

6"

1' -

0"

2' -

0"

2' -

6"

8' -

0"

3330

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:42

:26

AM

CWS

03/22/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.22A

UNIT B4 INT. ELEVATIONS

08/15/16

08/15/16

3/8" = 1'-0"1 UNIT B4 - KITCHEN ELEVATION 1 3/8" = 1'-0"2 UNIT B4 - KITCHEN ELEVATION 2

3/8" = 1'-0"3 UNIT B4 - KITCHEN ELEVATION 3 3/8" = 1'-0"4 UNIT B4 - BATH 1 ELEVATION 1

3/8" = 1'-0"5 UNIT B4 - BATH 1 ELEVATION 2

3/8" = 1'-0"6 UNIT B4 - BATH 1 ELEVATION 3 3/8" = 1'-0"7 UNIT B4 - BATH 1 ELEVATION 4

3/8" = 1'-0"8 UNIT B4 - BATH 1 ELEVATION 5 3/8" = 1'-0"9 UNIT B4 - BATH 1 ELEVATION 6

3/8" = 1'-0"10 UNIT B4 - BATH 1 ELEVATION 7

3/8" = 1'-0"12 UNIT B4 - BATH 2 ELEVATION 1 3/8" = 1'-0"13 UNIT B4 - BATH 2 ELEVATION 2

3/8" = 1'-0"14 UNIT B4 - BATH 2 ELEVATION 4 3/8" = 1'-0"15 UNIT B4 - BATH 2 ELEVATION 5

3/8" = 1'-0"11 UNIT B4 - BATH 2 ELEVATION 6

3/8" = 1'-0"16 UNIT B4 - UTILITY ELEVATION 3/8" = 1'-0"17

UNIT B4 - MAKE UP AIR CALC.ELEVATION

3/8" = 1'-0"18 UNIT B4 - A/C CLOSET ELEVATION 3/8" = 1'-0"19 UNIT B4 - DESK ELEVATION

1

1

1

11

11

1

1

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 35: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

REF.

DW

REF.

DW

BALCONY

BEDROOM 1

WIC

BATH 1

UTILITYROOM

KITCHEN

BEDROOM 2

BATH 2

WIC

LIVING

DESK/DININGAREA

A

3 12

6

13

1

33

12PAN.

A/C& WH

36"X60"TUB

36"X48"SHOWER

LIN

EN

2R

2S

1R1S

2R2S

SS

3

LIN

EN

36"X60"TUB/

SHOWER

2R

2S

1R1S

DESK

/A

3.2

3A

7

/A

3.2

3A

5

/A3.23A4

/A3.23A6

/A

3.2

3A

11

/A

3.2

3A

12

/A3.23A1

/A

3.2

3A

2

/A3.23A3

/A

3.2

3A

10

/A

3.2

3A

8

/A3.23A9

/

A3.23A

14

/A3.23A13

S22

6' - 3 1/2" 2' - 0 1/2" 2' - 10 1/2" 10' - 2" 5' - 5" 0' - 6" 3' - 11"

42' - 4"

3' -

8 1

/2

"3

' - 6

"

1' -

3"

1' -

4"

1' -

6 1

/2

"

3' -

0 1

/2

"3

' - 5

"4

' - 5

1/

2"

6' - 9 1/2" 6' - 6" 3' - 11 1/2" 4' - 8"

6' -

10

"6

' - 1

1 1

/2

"

13

5.0

5' - 2"

0' - 0"

1' - 6"

9' - 9"

9' - 7 1/2"

2' - 10"

4' - 5" 2' - 3" 3' - 0 1/2"

5' - 10 1/2" 2' - 0 1/2"

1' - 10"

3' - 8"

13

5.0

9' -

6 1

/2

"3

' - 4

1/

2"

3' -

10

"1

' - 1

0 1

/2

"

1' -

10

1/

2"

0' -

10

"

0' -

5 1

/2

"

2' -

1 1

/2

"7

' - 4

"

1' -

1 1

/2

"

1' -

3 1

/2

"

135.00°

13

5.0

0' - 2 1/2"

2' - 2 1/2"

2' - 10"

2' - 3"

2' - 9

"

1' - 1

1 1/2"

2' - 1

1"

5' - 7

"

7' -

10

1/

2"

2' -

4"

4' -

10

"2

' - 4

1/

2"

1' -

4"

1' -

6 1

/2

"

3' -

4"

A

SLOPE

1/4"=1'-0

"

3" SOLID BLOCKINGAT END OF EACH

RAIL(TYP)

42' GUARD

RAIL(TYP)

A

2' - 1

0"

TR

34

' - 3

"

2R

2S

SS

1R

1S

BALCONY

BEDROOM 1

WIC

BATH 1

UTILITYROOM

KITCHEN

BEDROOM 2

BATH 2

WIC

LIVING

DESK/DININGAREA

VPC

VP

C

T VP

TVP

T

VP

8'-6"A.F.F.

8'-0"A.F.F.

8'-6"A.F.F.

8'-6"A.F.F.

TR

FLOOR FINISHES

VP - VINYL PLANK

C - CARPET

T - TILE

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:42

:27

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.23

UNIT B5 FLOOR PLANS

08/15/16

08/15/16

1/4" = 1'-0"1 UNIT B5 FLOOR PLAN 1/4" = 1'-0"2 UNIT B5 FINISH FLOOR PLAN

1

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 36: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

SHELF

SHELF

OPEN TOLIVING

36" CAB. 24" OPENFOR D.W.

3" FILLER

3' -

6"

1' -

6"

3' -

0"

8' -

0"

1" ENDPANEL

7' - 4 3/4"

11' - 1 3/4"

30" OPENFOR RANGE

3" FILLER3" FILLER

3" FILLERMICROWAVE/VENTHOOD COMBO

TILE BULLNOSE

11' - 7 1/4" R.O.0' - 5 1/2"

12' - 10 3/4"

3' -

6"

1' -

6"

3' -

0"

8' -

0"

2742

3024

27421242

27" CAB.27" CAB.

FURROUT

3" FILLER

3" FILLER

1 1/2" FILLER

TILEBACKSPLASH

36" OPENFOR REF.

ENTRYDOOR

3342

24" PAN. FRONT21" TRASH

3618

9' - 2 3/4" R.O. 0' - 3 1/2"

14' - 9 1/2"

3' -

6"

1' -

6"

3' -

0"

8' -

0"

FURROUTSHOWER HEAD @ 7'-0" A.F.F.

SHOWER

3' - 0 3/4"

3' -

5"

1' -

11

"0

' - 8

"2

' - 6

"

8' -

6"

1

FURROUT

11

3

30" VB 12"DB 24" LIN. FRONT30" VB

MIRROR

4" BACKSPLASH

1 1/2" FILLER

TUB/SHOWER

1' -

3"

1' -

3"

0' -

8"

5' -

4"

8' -

6"

2' -

7"

1' -

0"

1' - 4"1' - 6 1/2"3' - 0 3/4"

14' - 1 1/4"

2' -

10

"4

' - 2

"

7' -

0"

FURROUT

11

SHOWERSEAT

SHOWER TUB3' - 0 3/4" 0' - 10"

9' - 0"

5' -

4"

0' -

8"

2' -

6"

8' -

6"

1' -

6"

1' -

5"

0' -

6"

1' -

3" 3

' - 2

"

FURROUT

1

1

SHOWER TUB

3' -

5"

1' -

11

"0

' - 8

"1

' - 3

"1

' - 3

"

8' -

6"

0' -

8"

2' -

6"

3' -

2"

4' - 1 1/4" 3' - 0 3/4"

14' - 1 1/4"

24" TB @4'-6" A.F.F.

FURROUT1 1/2" FILLER

4" BACK-SPLASH

11

TUB 24" LIN. FRONT12"DB33" VB

MIRROR

1' -

3"

1' -

3"

0' -

8"

5' -

4"

8' -

6"

2' -

7"

1' -

0"

2' -

10

"4

' - 2

"

7' -

0"

1' - 4"1' - 6"3' - 1 1/4"

12' - 10 1/4"

FURROUT

1

TUB/SHOWER

5' - 1 1/4"

5' - 7 1/4"

5' -

4"

1' -

5"

0' -

6"

1' -

3"

8' -

6"

FURROUT

TUB/SHOWER

SHOWER HEAD @ 7'-0" A.F.F.

24" TB @4'-6" A.F.F.

1

3' - 0 3/4"

3' -

5"

1' -

11

"0

' - 8

"1

' - 3

"1

' - 3

"

8' -

6"

FURROUT

WASHER & DRYER

7' - 1 3/4"

4' -

8"

1' -

2"

5' -

10

"

UTIL.1"X60" = 60 SQ.IN. FREE AREA UNDERCUT DOOR 1"

FREE AREA REQUIREMENTS

TOTAL FREE AREA REQUIRED = 100 SQ.IN.TOTAL FREE AREA PROVIDED = 3712 SQ.IN.

2 X (22"X83") =3652 SQ.IN.FREE AREA

6' - 3 3/4"3' - 5 3/4"

A/C CLOSETUNDERCUTDOOR 1"

RETURNAIR VENT

DESK

5' - 1 1/4"

10' - 0"

2' -

6"

1' -

0"

2' -

0"

2' -

6"

3030 3030

8' -

0"

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:42

:29

AM

CWS

03/22/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.23A

UNIT B5 INT. ELEVATIONS

08/31/16

08/15/16

3/8" = 1'-0"1 UNIT B5 - KITCHEN ELEVATION 1 3/8" = 1'-0"2 UNIT B5 - KITCHEN ELEVATION 2

3/8" = 1'-0"3 UNIT B5 - KITCHEN ELEVATION 3 3/8" = 1'-0"4 UNIT B5 - BATH 1 ELEVATION 1

3/8" = 1'-0"5 UNIT B5 - BATH 1 ELEVATION 2 3/8" = 1'-0"6 UNIT B5 - BATH 1 ELEVATION 3

3/8" = 1'-0"7 UNIT B5 - BATH 1 ELEVATION 4 3/8" = 1'-0"8 UNIT B5 - BATH 2 ELEVATION 1

3/8" = 1'-0"9 UNIT B5 - BATH 2 ELEVATION 2 3/8" = 1'-0"10 UNIT B5 - BATH 2 ELEVATION 3

3/8" = 1'-0"11 UNIT B5 - UTILITY ELEVATION 3/8" = 1'-0"12

UNIT B5 - MAKE UP AIR CALC.ELEVATION

3/8" = 1'-0"13 UNIT B5 - A/C CLOSET ELEVATION

3/8" = 1'-0"14 UNIT B5 - DESK ELEVATION

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 37: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

REF.

DN

DW

UP

7

6

5

4

3

2

1

21

20

19

18

17

16

15

14

13

12

11

10

9

8

REF.

DN

DW

UP

BEDROOM 1

WIC

BATH 1

UTILITYROOM

KITCHEN

BEDROOM 2

BATH 2

WIC

LIVING

PAN.

A/C& WH

36"X60"TUB

36"X48"SHOWER

LIN

EN

2R

2S

1R1S

2R2S

SS

LIN

EN

36"X60"TUB/

SHOWER 2R

2S

1R1S

/A

3.2

3C

4

/A

3.2

3C

5

/A3.23C6

/A3.23C7

/A

3.2

3C

11

/A

3.2

3C

12

/A3.23C1

/A

3.2

3C

2

/A3.23C3

/A

3.2

3C

8/

A3

.23

C9

/A3.23C10

/A3.23C13

3

123

6

13

1

3

3

12

A

S22

6' - 3 1/2" 2' - 0 1/2" 2' - 10 1/2" 10' - 2" 5' - 5" 0' - 6" 3' - 11"

42' - 4"

1' -

10

"5

' - 0

1/

2"

6' -

11

1/

2"

5' - 10 1/2" 2' - 0 1/2"

1' - 10"

3' - 8"

13

5.0

9' -

6 1

/2

"3

' - 8

"3

' - 6

1/

2"

1' -

10

1/

2"

1' -

10

1/

2"

0' -

10

"

0' -

5 1

/2

"

2' -

1 1

/2

"6

' - 4

1/

2"

2' -

1"

1' -

3 1

/2

"

135.00°

13

5.0

2' - 3"

2' - 9 1/2"

2' - 3"

7' -

10

1/

2"

2' -

4"

4' -

10

"1

' - 4

1/

2"

2' -

4"

1' -

6 1

/2

"3

' - 4

"

6' - 9 1/2" 6' - 9 1/2" 3' - 8" 4' - 8"

5' - 2"

1' - 6"

7' - 1"

2' - 8"

9' - 8 1/2"

3' -

8 1

/2

"3

' - 6

"1

' - 3

"

1' -

4"

1' -

6 1

/2

"

3' -

0 1

/2

"3

' - 5

"4

' - 5

1/

2"

2' - 9

"

1' - 1

1 1/2"3' -

9 1

/2"

4' - 8

1/2"

4' - 5" 2' - 3" 3' - 0 1/2"

A A

34

' - 3

"

17

TR

2R

2S

SS

CHASE

STUDY

BATH3

WETBAR

LIVING

S9

S23

3

A

2R

2S

LINEN

/A

3.2

3C

15

/A3.23C16

/A3.23C14

12

/A3.23C17

18

3

STORAGE

CLOSET

6' - 9 1/2" 7' - 5 1/2" 6' - 0"

1' - 10 1/2"

12' - 6 1/2"

0' - 5"

3' - 1 1/2"

10' - 11 1/2"

6' -

10

"6

' - 1

1 1

/2

"

16

' - 2

1/

2"

18

' - 0

1/

2"

34

' - 3

"

11' - 4" 3' - 0 1/2"

1' - 6 1/2"

1' - 4 1/2"

2' - 6"

24' - 5 1/2" 17' - 10 1/2"

42' - 4"

5' - 3 1/2"

1' -

9"

2' -

3 1

/2

"

2' -

2"

0' -

8"

5' -

10

1/

2"

0' - 10 1/2"2' - 3"

1' - 11"4' - 7 1/2"

3' - 5"

7' - 8"

1' - 2 1/2"

1' -

10

"4

' - 6

"6

' - 6

"

1' - 2

"0' -

7"

4' - 5

1/2"

2' - 3 1/2"

0' - 9"

4' - 7" 1' - 7"

0' - 8"

5' -

0 1

/2

"

13

5.0

0°36"X48"

SHOWER

BEDROOM 1

WIC

BATH 1

UTILITYROOM

KITCHEN

BEDROOM 2

BATH 2

WIC

LIVING

VPC

VP

C

T VP

TVP

T

VP

TR8'-6"A.F.F.

8'-0"A.F.F.

8'-6"A.F.F.

8'-6"A.F.F.

STUDY

BATH 3

WETBAR

LIVING

TVP

STOR

AGE CLOSET

8'-0"A.F.F.

8'-6"A.F.F.

FLOOR FINISHES

VP - VINYL PLANK

C - CARPET

T - TILE

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:42

:30

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.23B

UNIT B5.2 FLOOR PLANS

08/15/16

08/15/16

1/4" = 1'-0"1 UNIT B5.2 FLOOR PLAN

1/4" = 1'-0"2 UNIT B5.1 FLOOR PLAN

1/4" = 1'-0"3 UNIT B5.2 FINISH FLOOR PLAN

1/4" = 1'-0"4 UNIT B5.1 FINISH FLOOR PLAN

1

1

1

1

1

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 38: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

SHELF

SHELF

OPEN TOLIVING

24" OPENFOR D.W.

3" FILLER

1" ENDPANEL

7' - 4 3/4"

11' - 1 3/4"

3' -

6"

1' -

6"

3' -

0"

8' -

0"

30" OPENFOR RANGE

3" FILLER3" FILLER

3" FILLERMICROWAVE/VENTHOOD COMBO

TILE BULLNOSE

0' - 5 1/2" 11' - 7 1/4" R.O.

12' - 10 3/4"

3' -

6"

1' -

6"

3' -

0"

8' -

0"

2742

3024

2742 1242

27" CAB.27" CAB.

FURROUT

3" FILLER

3" FILLER

1 1/2" FILLER

TILEBACKSPLASH

36" OPENFOR REF.

ENTRYDOOR

3' -

6"

1' -

6"

3' -

0"

8' -

0"

9' - 2 3/4" R.O. 0' - 3 1/2"

14' - 9 1/2"

3342

24" PAN. FRONT

3618

21" TRASH

FURROUT

1

1

SHOWER TUB

24" TB @4'-6" A.F.F.

3' - 0 3/4"4' - 1 1/4"

14' - 1 1/4"

3' -

5"

1' -

11

"0

' - 8

"1

' - 3

"1

' - 3

"

8' -

6"

0' -

8"

2' -

6"

3' -

2"

FURROUT

11

3

4" BACKSPLASH

1 1/2" FILLER

TUB/SHOWER

1' - 4"1' - 6 1/2"3' - 0 3/4"

2' -

7"

1' -

0"

1' -

3"

1' -

3"

0' -

8"

5' -

4"

8' -

6"

2' -

10

"4

' - 2

"

7' -

0"

14' - 1 1/4"

30" VB 12"DB 30" VB 24" LIN. FRONT

MIRROR

FURROUTSHOWER HEAD @ 7'-0" A.F.F.

SHOWER

1

3' - 0 3/4"

3' -

5"

1' -

11

"0

' - 8

"2

' - 6

"

8' -

6"

FURROUT

11

SHOWERSEAT

SHOWER TUB

3' - 0 3/4" 0' - 10"

9' - 0"

5' -

4"

0' -

8"

2' -

6"

8' -

6"

1' -

6"

1' -

5"

0' -

6"

1' -

3" 3

' - 2

"

FURROUT

TUB/SHOWER

SHOWER HEAD @ 7'-0" A.F.F.

24" TB @4'-6" A.F.F.

1

3' - 0 3/4"

3' -

5"

1' -

11

"

0' -

8"

1' -

3"

1' -

3"

8' -

6"

FURROUT1 1/2" FILLER

4" BACKSPLASH

11

TUB

MIRROR

33" VB 12"DB 24" LIN. FRONT

1' - 4"1' - 6"3' - 1 1/4"

12' - 10 1/4"

1' -

3"

1' -

3"

0' -

8"

5' -

4"

8' -

6"

2' -

7"

1' -

0"

2' -

10

"4

' - 2

"

7' -

0"

12"DB

1

TUB/SHOWER

5' - 1 1/4"

5' - 7 1/4"

5' -

4"

1' -

5"

0' -

6"

1' -

3"

8' -

6"

FURROUT

WASHER & DRYER

7' - 1 3/4"

4' -

8"

1' -

2"

5' -

10

"

UTIL.1"X60" = 60 SQ.IN. FREE AREA UNDERCUT DOOR 1"

FREE AREA REQUIREMENTS

TOTAL FREE AREA REQUIRED = 100 SQ.IN.TOTAL FREE AREA PROVIDED = 3712 SQ.IN.

2 X (22"X83") =3652 SQ.IN.FREE AREA

6' - 3 3/4"

A/C CLOSETUNDERCUTDOOR 1"

RETURNAIR VENT

3' - 5 3/4"

TILEBACKSPLASH

1 1/2" FILLER

2442

27" CAB. 24"BEVERAGE

COOLER

1 1/2" FILLER

6' - 7 1/4" R.O.

3' -

6"

1' -

6"

3' -

0"

8' -

0"

FURROUT

1 1/2" FILLER OPEN SHELVING

24" CAB.

2442

(GLASSFRONT)

(GLASSFRONT)

SHOWER

1

2' -

6"

0' -

8"

5' -

4"

8' -

6"

4' - 1 1/4"1' - 0"

5' - 9 1/4"

FURROUT

1' -

6"

24" LIN. FRONT 15" DB 30" VB

11

MIRROR

4" BACK-SPLASH

SHOWER

1 1/2" FILLER

5' -

4"

0' -

8"

2' -

6"

8' -

6"

1' -

0"

2' -

7"

1' - 4 1/2" 1' - 6 1/2" 3' - 0 3/4"

13' - 1 3/4"

SHOWERSHELF

FURROUT

15" DB

1' -

6"

SHOWER HEAD @ 7'-0" A.F.F.

24" TB @4'-6" A.F.F.

SHOWER

1

3' - 0 3/4"

3' -

5"

1' -

11

"0

' - 8

"2

' - 6

"

8' -

6"

FURROUT

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:42

:32

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.23C

UNIT B5.2 INT. ELEVATIONS

08/31/16

08/15/16

3/8" = 1'-0"1 UNIT B5.2 - KITCHEN ELEVATION 1 3/8" = 1'-0"2 UNIT B5.2 - KITCHEN ELEVATION 2

3/8" = 1'-0"3 UNIT B5.2 - KITCHEN ELEVATION 3 3/8" = 1'-0"4 UNIT B5.2 - BATH 1 ELEVATION 1

3/8" = 1'-0"5 UNIT B5.2 - BATH 1 ELEVATION 2 3/8" = 1'-0"6 UNIT B5.2 - BATH 1 ELEVATION 3

3/8" = 1'-0"7 UNIT B5.2 - BATH 1 ELEVATION 4 3/8" = 1'-0"8 UNIT B5.2 - BATH 2 ELEVATION 1

3/8" = 1'-0"9 UNIT B5.2 - BATH 2 ELEVATION 2

3/8" = 1'-0"10 UNIT B5.2 - BATH 2 ELEVATION 3 3/8" = 1'-0"11 UNIT B5.2 - UTILITY ELEVATION

3/8" = 1'-0"12

UNIT B5.2 - MAKE UP AIR CALC.ELEVATION

3/8" = 1'-0"13 UNIT B5.2 - A/C CLOSET ELEVATION 3/8" = 1'-0"14 UNIT B5.1 - WET BAR ELEVATION

3/8" = 1'-0"15 UNIT B5.1 - BATH 3 ELEVATION 1 3/8" = 1'-0"16 UNIT B5.1 - BATH 3 ELEVATION 2 3/8" = 1'-0"17 UNIT B5.1 - BATH 3 ELEVATION 3

1

1 1

1

11

1

No. Revision Date

1 REV 1 Date 1

Page 39: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

REF

.

DW

REF

.

DW

BALCONY

BEDROOM 2

WIC

BATH 2

LIVING

BEDROOM 1

WIC

BATH 1

KITCHEN

UTIL.PANTRY

1R

1S

DE

SK

A/C& WH

36"X60"TUB

36"X48"SHOWER

LIN

EN

SS 1R1S

2R

2S

2R

2S

1R

1S

36"X60"TUB/

SHOWER

LIN

EN

2R2S

1R

1S

1R

1S

12

3 3

A

16

3

12

3

4

6

13

1

A

/A

3.2

4A

5

/A

3.2

4A

7

/A3.24A4

/A3.24A6

/A

3.2

4A

14

/A3.24A13

/A

3.2

4A

3

/A

3.2

4A

1

/A3.24A2/

A3

.24

A1

1

/A

3.2

4A

12

/A

3.2

4A

10

/A

3.2

4A

8

/A3.24A9

2' -

4 1

/2

"2

' - 0

1/

2"

1' -

10

"3

' - 9

"

1' -

4 1

/2

"

1' -

5 1

/2

"

1' -

6 1

/2

"

3' -

4"

16

' - 0

"

40

' - 3

"

2' - 0 1/2"3' - 0 1/2"11' - 0 1/2"

5' - 8 1/2" 1' - 3"

9' - 0"12' - 9 1/2"20' - 2 1/2"

42' - 0"

1' -

6"

1' -

4 1

/2

"

1' -

6 1

/2

"3

' - 4

"

4' -

8 1

/2

"1

5' -

2 1

/2

"1

2' -

9 1

/2

"7

' - 6

1/

2"

5' - 8"2' - 1"

1' - 4"

1' - 8"3' - 0"

1' - 11"

12' - 10"7' - 9"

6' -

0 1

/2

"3

' - 0

"

1' -

11

1/

2"

4' -

2 1

/2

"

6' -

4"

3' -

4"

1' -

4 1

/2

"

1' -

2 1

/2

" 4' -

5"

1' -

11

"3

' - 8

1/

2"

2' -

0"

2' -

0"

6' - 8"4' - 6 1/2"1' - 11 1/2"4' - 11 1/2"

2' - 3 1/2"

1' - 10"

1' - 6"5' - 10 1/2"

5' -

7 1

/2

"

0' - 10"

0' - 5 1/2"

2' - 1 1/2"6' - 10 1/2"

5' - 10"

SLOPE

1/4"=1'-0

"

3" SOLID BLOCKINGAT END OF EACHRAIL(TYP)

42" GUARDRAIL(TYP)

TR

C C

2R2SSS

BALCONY

BEDROOM 2

WIC

BATH 2

LIVING

BEDROOM 1

WIC

BATH 1

KITCHEN

UTIL.

VP

C

T

C

VP C

VP

T

8'-0"A.F.F.

8'-6"A.F.F.

8'-6"A.F.F.

7'-0"A.F.F.

8'-6"A.F.F.

TR

FLOOR FINISHES

VP - VINYL PLANK

C - CARPET

T - TILE

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:42

:33

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.24

UNIT B6 FLOOR PLANS

08/15/16

08/15/16

1/4" = 1'-0"1 UNIT B6 FLOOR PLAN 1/4" = 1'-0"2 UNIT B6 FINISH FLOOR PLAN

1

1

1

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 40: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

SHELF

SHELF

2 1/2" FILLER3" FILLER

3" FILLER

TILE BULLNOSE

3042 3642

3024

3642

3618

36" CAB.36" CAB.18" CAB. 30" OPENFOR RANGE

36" OPENFOR REF.

3' -

0"

1' -

6"

3' -

6"

15' - 6 3/4" R.O.

MICROWAVE/VENTHOOD COMBO

FURROUT

3342 3342

21" TRASH33" DB36" PAN. FRONT

TILE BACKSPLASH

3" FILLER

3" FILLER

3" FILLER

ENTRYDOOR

0' - 3 1/2" 10' - 1 1/4" R.O.

15' - 10"

3' -

6"

1' -

6"

3' -

0"

8' -

0"

FURROUT

24" TB @4'-6" A.F.F.

SHOWERSEAT

SHOWER

1

2' -

10

"

5' -

4"

0' -

8"

2' -

6"

8' -

6"

3' - 0 3/4"

8' - 5 1/4"

FURROUT

1' -

6"

11

33" VB 12"DB 33" VB

MIRROR

4" BACKSPLASH

1 1/2"FILLER

TUB/SHOWER

2' -

10

"4

' - 2

"

7' -

0"

2' -

7"

1' -

0"

1' -

3"

1' -

3"

0' -

8"

5' -

4"

8' -

6"

3' - 0 3/4" 1' - 6 1/2" 1' - 5 1/2"

12' - 8 3/4"

FURROUT

TUBSHOWER

SHOWER HEAD @ 7'-0" A.F.F.

3' - 0 3/4" 0' - 3 1/2"

8' - 5 1/4"

1' -

5"

0' -

6"

1' -

3" 3

' - 2

"

3' -

5"

1' -

11

"0

' - 8

"2

' - 6

"

8' -

6"

1

1

FURROUT

36" LIN. FRONT

1 1/2" FILLER

SHOWER TUB

FURRDOWN

1

1

3' - 4 1/4" 1' - 11"

0' - 3 1/2"

4' - 1 1/4"

12' - 8 3/4"

7' -

0"

0' -

8"

2' -

6"

3' -

5"

1' -

11

"0

' - 8

"1

' - 3

"1

' - 3

"

8' -

6"

FURROUT

1' -

6"

SHOWER HEAD @ 7'-0" A.F.F.

24" TB @4'-6" A.F.F.

TUB/SHOWER

3' - 0 3/4"

1' -

3"

1' -

3" 0

' - 8

"1' -

11

"3

' - 5

"

8' -

6"

1

FURROUT

1

5' - 1 1/4"

5' -

3 1

/4

"1

' - 5

"

0' -

6"

1' -

3"

8' -

5 1

/4

"

6' - 2"

TUB/SHOWER

FURROUT

24" LIN. FRONT 15" DB 36" VB

1 1/2" FILLER

4" BACK-SPLASH

1 1

MIRROR

3' - 0 3/4"1' - 6 1/2"1' - 4 1/4"

12' - 6"

0' -

8"

1' -

3"

1' -

3" 3

' - 2

"

1' -

0"

2' -

7"

4' -

2"

2' -

10

"

7' -

0"

WASHER & DRYER

7' - 1"

1' -

2"

4' -

8"

5' -

10

"

UTIL.1"X60" = 60 SQ.IN. FREE AREA UNDERCUT DOOR 1"

FREE AREA REQUIREMENTS

TOTAL FREE AREA REQUIRED = 100 SQ.IN.TOTAL FREE AREA PROVIDED = 3712 SQ.IN.

2 X (22"X83") =3652 SQ.IN. FREEAREA

6' - 7 1/2"A/C CLOSETUNDERCUT

DOOR 1"

RETURNAIR VENT

DESKCOAT CLOSET

5' - 4 1/4" R.O.4' - 0 1/4"

13' - 0 1/4"

2' -

6"

2' -

0"

1' -

0"

2' -

6"

8' -

0"

3030 3030

15" DB 15" DB

36" CAB. 12" CAB.24" OPENFOR D.W.

1" ENDPANEL

1" ENDPANEL

OPEN TOLIVING 3

' - 6

"1

' - 6

"3

' - 0

"

8' -

0"

6' - 4" 5' - 5 3/4"

15' - 6 3/4"

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:42

:34

AM

CWS

03/22/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.24A

UNIT B6 INT. ELEVATIONS

08/15/16

08/15/16

3/8" = 1'-0"1 UNIT B6 - KITCHEN ELEVATION 1 3/8" = 1'-0"2 UNIT B6 - KITCHEN ELEVATION 2

3/8" = 1'-0"4 UNIT B6 - BATH 1 ELEVATION 1

3/8" = 1'-0"5 UNIT B6 - BATH 1 ELEVATION 2 3/8" = 1'-0"6 UNIT B6 - BATH 1 ELEVATION 3

3/8" = 1'-0"7 UNIT B6 - BATH 1 ELEVATION 4 3/8" = 1'-0"8 UNIT B6 - BATH 2 ELEVATION 1

3/8" = 1'-0"9 UNIT B6 - BATH 2 ELEVATION 2

3/8" = 1'-0"10 UNIT B6 - BATH 2 ELEVATION 3 3/8" = 1'-0"11 UNIT B6 - UTILITY ELEVATION

3/8" = 1'-0"12

UNIT B6 - MAKE UP AIR CALC.ELEVATION

3/8" = 1'-0"13 UNIT B6 - A/C CLOSET ELEVATION 3/8" = 1'-0"14 UNIT B6 - DESK ELEVATION

3/8" = 1'-0"3 UNIT B6 - KITCHEN ELEVATION 3

1

1

11

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 41: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

DW

REF

.

DW

REF

.

BALCONY

BA

LC

ON

Y

BEDROOM 1

WIC

BATH 1

LIVING/KITCHEN

BEDROOM 2

WIC

BATH 2

UTILITYROOM

READINGNOOK

A

3

3

3

12

6

3

7

12

1

2R2S

1R

1S

SS

2R2S

1R

1S

LIN

EN

42"X60"TUB/SHOWER

PA

N.

1R

1S

36"X48"SHOWER

LIN

EN

A/C& WH

2R2S

1R1S

SS

/A

3.2

5A

5

/A

3.2

5A

3

/A3.25A 4

/A

3.2

5A

1

/A3.25A 2

/A3.25A 10

/A

3.2

5A

9

/A

3.2

5A

8

/A

3.2

5A

6

/A3.25A 7

/A

3.2

5A

11

A S1

A

3' - 3 1/2"2' - 4"9' - 5 1/2"0' - 10"5' - 5"6' - 7 1/2"

3' -

4"

1' -

6 1

/2

"

1' -

4"

2' -

4 1

/2

"4

' - 1

0"

1' -

5 1

/2

"8

' - 5

1/

2"

13

' - 0

"

38

' - 6

1/

2"

7' -

9 1

/2

"7

' - 7

"5

' - 6

1/

2"

5' -

8 1

/2

"2

' - 0

1/

2"

3' -

0"

3' -

8"

4' - 8 1/2"

0' - 6 1/2"

2' - 2 1/2"8' - 4"0' - 6 1/2"4' - 3 1/2"4' - 3 1/2"3' - 10 1/2"6' - 1 1/2"6' - 2"2' - 10"

1' - 11 1/2"

2' - 6"

2' -

9"

2' -

7"

1' -

10

1/

2"

1' -

11

"

2' -

0 1

/2

"

3' - 2"2' - 3"1' - 11 1/2"

2' -

3"

2' -

5"

0' -

11

"

1' -

6 1

/2

"

1' -

4"

1' -

6"4

' - 3

"4

' - 0

1/

2"

1' -

11

1/

2"

2' -

5"

1' - 11 1/2"

4' -

8"

4' -

7 1

/2

"

49' - 5 1/2"

SL

OP

E

1/

4"=

1'-

0"

3" SOLID BLOCKINGAT END OF EACHRAIL(TYP)

42" GUARDRAIL(TYP)

TR

C

16

2' - 1 1/2"

1' - 2"4' - 5"1' - 0"7' - 0 1/2"

2' - 10"

1' -

6"

1R

1S

2R

2S

18

BALCONY

BA

LC

ON

Y

BEDROOM 1

WIC

BATH 1

LIVING/KITCHEN

BEDROOM 2

WIC

BATH 2

UTILITYROOM

READING NOOK

T

C

VPC

VP

C

T

VP

TVP

8'-6"A.F.F.

8'-0"A.F.F.

8'-6"A.F.F. TR

FLOOR FINISHES

VP - VINYL PLANK

C - CARPET

T - TILE

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

PL

AN

TE

R

PL

AN

TE

R

3' - 0" 46' - 0 1/2" 1' - 6"

51' - 1"

2' -

7 1

/2

"1

1' -

11

"

0' -

5 1

/2

"1

6' -

0"

42" GUARDRAIL TYP.

601 SF

B7 ROOF TERRACE

BEDROOM 2LIVING/KITCHENBEDROOM 1

3' - 1 1/2" 0' - 8 1/2"

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:42

:35

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.25

UNIT B7 FLOOR PLANS

08/15/16

08/15/16

1/4" = 1'-0"1 UNIT B7 FLOOR PLAN 1/4" = 1'-0"2 UNIT B7 FINISH FLOOR PLAN

1/4" = 1'-0"3 UNIT B7 AMENITY DECK ROOF TERRACE

1

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 42: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

SHELF

SHELF

1" FILLEROPEN SHELVING3" FILLER

3" FILLER 36" OPENFOR REF.

TILE BACKSPLASH

19' - 9"

15' - 5 1/4" R.O. 0' - 3 1/2"

3' -

6"

1' -

6"

3' -

0"

8' -

0"

3042 2442

3618

18" CAB. 24" OPENFOR D.W.

FURROUT

1842

18" CAB.36" CAB. 24" PAN. FRONT

3342

21" TRASH

3" FILLER

3" FILLER

TILEBACKSPLASH

9' - 5 1/4" R.O.

3' -

0"

1' -

6"

3' -

6"

8' -

0"

FURROUT

1" FILLER MICROWAVE/VENTHOOD COMBO

3024

3342

33" CAB.1" FILLER 30" OPENFOR RANGE

SHOWER HEAD @ 7'-0" A.F.F.

24" TB @4'-6" A.F.F.

TUB/SHOWER

3' - 0 3/4"

1

FURROUT

3' -

5"

1' -

11

"

0' -

8"

1' -

3"

1' -

3"

8' -

6"

1

TUB/SHOWER5' - 1 1/4"

5' - 9 1/4"

5' -

4"

1' -

5"

0' -

6"

1' -

3"

8' -

6"

FURROUT

24" LIN. FRONT 36" VB 15" DB 36" VB

MIRROR

4" BACKSPLASH

1 1/2" FILLER

11

TUB/SHOWER

3' - 0 3/4"1' - 6 1/2"1' - 4"

15' - 5 1/4"

1' -

3"

1' -

3"

0' -

8"

5' -

4"

8' -

6"

2' -

7"

1' -

0"

2' -

10

"4

' - 2

"

7' -

0"

FURROUT

1

24" TB @4'-6" A.F.F.

SHOWER

SHOWER HEAD @ 7'-0" A.F.F.

3' - 0 3/4"

3' -

5"

1' -

11

"0

' - 8

"2

' - 6

"

8' -

6"

FURROUT

1

4' - 1 1/4" 1' - 0"

6' - 1 1/4"

5' -

4"

0' -

8"

2' -

6"

8' -

6"

SHOWER

FURROUT

1' -

6"

MIRROR

33" VB12"DB 12"DB24" LIN. FRONT

1 1/2" FILLER

4" BACKSPLASH

SHOWER

1

1

2' -

6"

0' -

8"

5' -

4"

8' -

6"

1' -

6"

SHOWERSEAT

2' -

7"

1' -

0"

2' -

10

"4

' - 2

"

7' -

0"

3' - 0 3/4"1' - 6 1/2"1' - 4"

12' - 10 1/4"

FURROUT

WASHER & DRYER

7' - 8 1/4"

1' -

2"

4' -

8"

5' -

10

"

UTIL. 1"X34" = 34 SQ.IN.FREE AREA

24"X83" =1992 SQ.IN.FREE AREA

UNDERCUTDOOR 1"

FREE AREA REQUIREMENTS

TOTAL FREE AREA REQUIRED = 100 SQ.IN.TOTAL FREE AREA PROVIDED = 2026 SQ.IN.

3' - 11 1/4"

A/C CLOSET

RETURN AIR VENT

UNDERCUT DOOR 1"

8' - 4"

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:42

:36

AM

CWS

03/22/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.25A

UNIT B7 INT. ELEVATIONS

08/15/16

08/15/16

3/8" = 1'-0"1 UNIT B7 - KITCHEN ELEVATION 1 3/8" = 1'-0"2 UNIT B7 - KITCHEN ELEVATION 2

3/8" = 1'-0"3 UNIT B7 - BATH 1 ELEVATION 1 3/8" = 1'-0"4 UNIT B7 - BATH 1 ELEVATION 2

3/8" = 1'-0"5 UNIT B7 - BATH 1 ELEVATION 3 3/8" = 1'-0"6 UNIT B7 - BATH 2 ELEVATION 1

3/8" = 1'-0"7 UNIT B7 - BATH 2 ELEVATION 2 3/8" = 1'-0"8 UNIT B7 - BATH 2 ELEVATION 3

3/8" = 1'-0"9 UNIT B7 - UTILITY ELEVATION 3/8" = 1'-0"10

UNIT B7 - MAKE UP AIR CALC.ELEVATION

3/8" = 1'-0"11 UNIT B7 - A/C CLOSET ELEVATION

11

11

1

No. Revision Date

1 REV 1 Date 1

Page 43: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

REF

.

DN

DW

UP6 5 4 3 2 1

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

REF

.

DN

DW

UP

BALCONY

KITCHEN

DINING

BATH 1

BEDROOM 1UTIL.

WIC

PA

NT

RY

SS

1R

1S

2R2S

2R

2S

/A

3.2

6A

1 /A

3.2

6A

2

A/C& WH

/A

3.2

6A

9

/A

3.2

6A

10

1R

1S

36"X48"SHOWER L

INE

N

36"X60"TUB

/A

3.2

6A

3 /A

3.2

6A

4

/A

3.2

6A

8

/A3.26A5

/A3.26A7

/A

3.2

6A

6

39

6

13

4

3

3

1

8

2' - 4" 3' - 1 1/2" 2' - 10 1/2" 3' - 6" 2' - 3" 1' - 4" 1' - 6 1/2"

20' - 4"

24

' - 5

1/

2"

12

' - 8

"3

' - 2

"5

' - 5

"1

' - 4

"

49

' - 2

"

0' -

7 1

/2

"0

' - 6

1/

2"

12

' - 1

0"

7' -

5 1

/2

"3

' - 1

1/

2"

2' -

10

"

1' -

9 1

/2

"

1' -

6"

1' -

9"

1' -

7 1

/2

"

1' -

10

"

1' -

6 1

/2

"

2' -

3"

3' -

0 1

/2

"1

' - 2

1/

2"

1' - 8" 4' - 7 1/2" 3' - 5 1/2" 7' - 7"

22' - 2"

7' -

1"

1' -

1 1

/2

"4

' - 8

1/

2"

4' -

3"

2' -

10

1/

2"

3' - 9 1/2" 3' - 9" 1' - 6 1/2" 4' - 8"

1' - 3 1/2" 1' - 11 1/2"

0' - 8" 4' - 5" 1' - 11 1/2" 4' - 6"

5' - 1 1/2" 5' - 2 1/2"

0' - 10"

0' - 5 1/2"

2' - 1 1/2" 4' - 1"

3" SOLID BLOCKINGAT END OF EACHRAIL(TYP)

SLOPE

1/4"=1'-0"

42" GUARDRAIL(TYP)

S20S1924

TR

CHASE

BEDROOM 2

BATH 2

WETBAR

LIVING

/A3.26A 11

/A

3.2

6A

14

/A

3.2

6A

12

/A3.26A13

3 3

3

14

2R

2S

LIN

EN

PAN.

1R

1S

36"X60"TUB/SHOWER

0' -

7"

5' -

2"

1' -

4 1

/2

"

1' -

4"

1' -

6 1

/2

"

3' -

4"

28

' - 1

1 1

/2

"

2' -

11

"1

0' -

8 1

/2

"1

2' -

4"

11' - 5 1/2" 2' - 3 1/2" 0' - 6"

19' - 9 1/2"

2' - 10" 5' - 7 1/2" 1' - 11" 3' - 8 1/2" 1' - 2"

20' - 6"

7' - 10 1/2" 2' - 0 1/2"

2' - 3"

1' - 11 1/2" 5' - 1"

1' -

11

1/

2"

4' -

6 1

/2

"4

' - 6

1/

2"

S19 S21

17

BALCONY

KITCHEN

DINING

BATH 1

BEDROOM 1UTIL.

WIC

C

VP

T

C

CVPTVP

8'-6"A.F.F.

8'-6"A.F.F.

7'-0"A.F.F.

8'-0"A.F.F.

TR

BEDROOM 2

BATH 2

WETBAR

LIVING

C

VP

T

VP

C T

8'-0"A.F.F.

8'-6"A.F.F.

FLOOR FINISHES

VP - VINYL PLANK

C - CARPET

T - TILE

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:42

:37

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.26

UNIT B8.2 FLOOR PLANS

08/15/16

08/15/16

1/4" = 1'-0"1 UNIT B8.2 FLOOR PLAN

1/4" = 1'-0"2 UNIT B8.1 FLOOR PLAN

1/4" = 1'-0"3 UNIT B8.2 FINISH FLOOR PLAN

1/4" = 1'-0"4 UNIT B8.1 FINISH FLOOR PLAN

1

1

1

1

1

No. Revision Date

1 REV 1 Date 1

Page 44: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

SHELF

SHELF

24" OPENFOR D.W.

16' - 10 1/2"

36" CAB. 21" TRASH1 1/2" FILLER

3' -

0"

7' - 1 1/4"0' - 3 1/2"0' - 10"4' - 8 1/2"

3" FILLER MICROWAVE/VENTHOOD COMBO 3" FILLER

33" CAB. 33" CAB. 33" DB

33423342

3024

3342

30" PAN. FRONT

TILE BULLNOSE

30" OPENFOR RANGE

16' - 10 1/2" R.O.

2' -

0"

1' -

6"

1' -

6"

3' -

0"

3618

8' -

0"

30" OPENFOR REF.

FURROUT

SHOWER HEAD @ 7'-0" A.F.F.

SHOWER

1

0' - 3 1/2" 3' - 0 3/4"

9' - 1 1/4"

2' -

6"

0' -

8"1

' - 1

1"

3' -

5"

8' -

6"

2' -

10

"

FURROUT

SHOWERSEAT

SHOWER

1

3' - 0 3/4"

5' -

4"

0' -

8"

2' -

6"

8' -

6"

1' -

6"

FURROUT

11

30" VB 30" VB 12"DB12"DB

MIRROR

4" BACKSPLASH

1 1/2"FILLER3' - 0 3/4" 1' - 6 1/2" 1' - 4"

14' - 1 1/4"

5' -

4"

0' -

8"

1' -

3"

1' -

3"

8' -

6"

1' -

0"

2' -

7"

4' -

2"

2' -

10

"

7' -

0"

FURROUT

12"DB

24" TB @4'-6" A.F.F.

3' - 0 3/4"SHOWER TUB

1

1

4' - 1 1/4" 0' - 3 1/2" 4' - 4 1/2" 3' - 0 3/4"

14' - 1 1/4"

3' -

5"

1' -

11

"0

' - 8

"1

' - 3

"1

' - 3

"

8' -

6"

1' -

6"

0' -

8"

2' -

6"

3' -

2"

FURROUT FURROUT

TUB30" LIN. FRONT

1 1/2" FILLER

1

5' - 1 1/4"0' - 3 1/2"

2' - 10 1/4"

9' - 1 1/4"

7' -

0"

5' -

4"

1' -

5"

0' -

6"

1' -

3"

8' -

6"

FURRDOWN

WASHER & DRYER

5' - 8 1/2"

1' -

2"

4' -

8"

5' -

10

"

UTIL.1"X60" = 60 SQ.IN. FREE AREA

2 X (22"X83") = 3652 SQ.IN. FREE AREA

UNDERCUT DOOR 1"

FREE AREA REQUIREMENTS

TOTAL FREE AREA REQUIRED = 100 SQ.IN.TOTAL FREE AREA PROVIDED = 3712 SQ.IN.

A/C CLOSET

RETURN AIR VENT

9' - 7"

2442

24"BEVERAGE

COOLER

1 1/2" FILLER

1 1/2" FILLER

TILEBACKSPLASH

3' -

6"

1' -

6"

3' -

0"

8' -

0"

7' - 1 1/4" R.O.

FURROUT

2442

24" CAB.33" CAB.

1 1/2" FILLER OPEN SHELVING

(GLASSFRONT)

(GLASSFRONT)

SHOWER HEAD @ 7'-0" A.F.F.

SHOWER

24" TB @4'-6" A.F.F.

5' - 9"3' - 0 3/4"

12' - 8 3/4"

1' -

3"

1' -

3" 0

' - 8

"1' -

11

"3

' - 5

"

8' -

6"

1

FURROUT

TUB/SHOWER

5' - 1 1/4"

5' - 7 1/4"

5' -

4"

1' -

5"

0' -

6"

1' -

3"

8' -

6"

1

FURROUT

1 1

33" VB12"DB24" LIN. FRONT

2" FILLER

TUB/SHOWER

5' -

4"

0' -

8"

1' -

3"

1' -

3"

8' -

6"

1' -

0"

2' -

7"

3' - 0 3/4"1' - 6 1/2"1' - 4"5' - 11 1/2"

12' - 8 3/4"

4' -

2"

2' -

10

"

7' -

0"

MIRROR

4" BACK-SPLASH

FURROUT

NOTE: UNITS WITH WALK-IN SHOWERS SHOULD HAVEFRAMELESS SHOWER ENCLOSURES W/DOORS HANGINGOFF OF WALL, 6' DOOR HEIGHT.

NOTE: QUARTER ROUND INSTALLED FOR VINYL PLANKFLOORING BASE. WOOD OR FINGER JOINTED WOOD BASEBOARD THROUGHOUT.

NOTE: CARPET IS 100% NYLON 25 OUNCE W/ 1/2" 6LB.CARPET PAD.

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS ANDSPACES, TEMPORARY OR PERMANENT, SHALL BEACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES PERIBC 1103.1

REFER TO SHEET A3.2B-A3.2D FOR ANSI ADAPTABLE UNITCLEAR FLOOR AREAS AND # NOTES.

DESIGNATED TYPE B UNITS PER FHA & ICC/ANSI A117.1-2003 AT ALL FLOORS.

GRAB BARS INSTALLED AT REQUEST OF FUTURE TENANTBUT BLOCKING MUST BE PROVIDED AT TIME OF INITIALCONSTRUCTION

SMOKE DETECTORS WITHIN THE UNIT ARE TO BEINTERCONNECTED IN SUCH A WAY THAT ACTIVATION OFONE DETECTOR WILL ACTIVATE THEM ALL.

REFER TO SHEET A3.0 FOR ALL TYPICAL UNIT DETAILS.

REFER TO SHEET A3.1 FOR THE WINDOW AND DOORSCHEDULE.

TYPE B ADAPTABLE UNITSPER FHA AND ICC/ANSI A117.1-2009(SEE SHEETS A1.3, A1.3A, A1.3B & A1.4)

GRAB BAR INSTALLED @ REQUEST OF RESIDENT.PROVIDE SUFFICIENT ADDITIONAL BLOCKING AS PRE-SCRIBED IN ACCESSIBILITY GUIDE- LINES (RE: A1.3FAIR HOUSING ACT UNITS)

1

REMOVABLE BASE CABINET TO CREATE ADDITIONALKNEE SPACE BENEATH COUNTER. EXTEND FLOORINGUNDER CABINET & FINISH ADJACENT WALL SURFACES/CABINETS AT TIME OF INITIAL CONSTRUCTION.REMOVABLE ONE- PIECE COUNTER-TOP TO BE RE-PLACED BY TWO-PIECE COUNTER- TOP AT REQUESTOF TENANT.

2

REMOVABLE VANITY BASE CABINET TO CREATEADDITIONAL KNEE SPACE BENEATHCOUNTERTOP. EXTEND FLOORING UNDER CABINET& FINISH ADJACENT WALL SURFACES /CABINETSAT TIME OF INITIAL CONSTRUCTION. SUPPLY TWO-PIECE COUNTERTOP IF REQUESTED BY TENANT

3

8/

31

/2

01

6 9

:42

:39

AM

CWS

03/21/16

BAT

MEM

13-1926

WE

ST

5T

H S

TR

EE

T1

30

1 W

. 5T

H S

T.

AU S

TIN

, TX

78

70

3

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

A3.26A

UNIT B8.2 INT. ELEVATIONS

08/31/16

08/15/16

3/8" = 1'-0"1 UNIT B8.2 - KITCHEN ELEVATION 1 3/8" = 1'-0"2 UNIT B8.2 - KITCHEN ELEVATION 2

3/8" = 1'-0"3 UNIT B8.2 - BATH 1 ELEVATION 1 3/8" = 1'-0"4 UNIT B8.2 - BATH 1 ELEVATION 2

3/8" = 1'-0"5 UNIT B8.2 - BATH 1 ELEVATION 3 3/8" = 1'-0"6 UNIT B8.2 - BATH 1 ELEVATION 4

3/8" = 1'-0"7 UNIT B8.2 - BATH 1 ELEVATION 5 3/8" = 1'-0"8 UNIT B8.2 - BATH 1 ELEVATION 6

3/8" = 1'-0"9 UNIT B8.2 - UTILITY ELEVATION

3/8" = 1'-0"10

UNIT B8.2 - A/C CLOSET & MAKE UP AIRCALC. ELEVATION

3/8" = 1'-0"11 UNIT B8.1 - WET BAR ELEVATION 3/8" = 1'-0"12 UNIT B8.1 - BATH 2 ELEVATION 1

3/8" = 1'-0"13 UNIT B8.1 - BATH 2 ELEVATION 2

3/8" = 1'-0"14 UNIT B8.1 - BATH 2 ELEVATION 3

11

11

11

1

1

No. Revision Date

1 REV 1 Date 1

Page 45: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

UP

UP

UP

UP

FITNESS

HOSPITALITYBAR

OFFICE OFFICE

WORKROOM

COOLDOWN

CONFERENCE

LOUNGE

IDFCLOSETOVERFLOW

PACKAGEROOM

LEASING

WIFI

FO

UNT

AIN

BA

SIN

BE

NC

HB

EN

CH

COMPUTERROOM

COPY

UC REF

TRASH

COOLERTOWEL

DROPTOWEL

BOTTLEFILLER

TV

TV

DISPLAY TV

UC REF

TRASH

UC REF UC REFUC REF

COFFEE

ICE

STORAGETOWEL

REF

.

TV

MIRRORWALL

DIVIDER WALL

SHELVING TOWER

LOW BOOKSHELVING

CO

CO

CO

CO

SPLITTERBO

X

PON

D

SEDIM

ENTA

TION

MH

MH

MH

PR

OP

ER

TY

LIN

E

20

' SE

TB

AC

K

8' SETBACK

17

' SE

TB

AC

K

30

' SE

TB

AC

K

15' STORM ESMT

EQUIP. & BLDG ESMT.

ACCESS & UNDERGROUND ESMT.

NUNIT B5.1

800 SF

UNIT A9.1460 SF

UNIT A13.1471

UNIT A9.1460 SF

UNIT B8.1585 SF

N

UNIT A13.1471

10 SP

14 SP

15 SP

15 SP

9 SP

7 SP

RETAIL

DOGWASH

MENS RR

WOMENSRR

BIKESTORAGE

TELECOMROOM

MAIL/PACKAGE ROOM

EXHAUSTSHAFT

RAMP DOWN @ 6.25%.

FOR 144'-0"

INTAKESHAFT

VAN

WE

ST

5T

H S

TR

EE

T

ORCHARD STREET

ELEV. 1

STAIR 1

STAIR 2

TRASH/RECYCLING

ELECTRICAL ROOM

OVERHEAD PIVOTENTRY GATE

475.64

476.1

UP 2

9'-

8"

@ 1

1.0

%

+ 3

.3 F

T

476.1

+ 0

.18

FT

476.1

ELEV. 1CNTL

RM

476.1

STOR.

FLAT476.1

FLAT476.1

476.1

UP

479.80UP UP

475.24

476.0

476.1

472.87

BERM

TRANSFORMER NICHE

475.40

475.86

476.10

476.15

476.10

476.25473.47472.84

472.78472.75

476.10473.71

473.54

SH

EE

T A

4.1

A

SH

EE

T A

4.1

B

ENTRANCE

(SHADED BYPODIUM EDGE

ABOVE)

ENTRANCE

(SHADED BYPODIUM EDGE

ABOVE)

ENTRANCE

(SHADED BYPODIUM EDGEABOVE)

1' -

0"

87

' - 2

1/

2"

DOWN 19' - 2 1/2" @ 8.25%

-1.6 FT474.5

UP 2

9'-

8"

@ 0

.53

%

STAIR3

476.10

476.10

SL

OP

E

1/

4"=

1'-

0"

TRASH COMPACTOR

476.10 476.10

5' - 6" 10' - 0" 5' - 0" 10' - 0" 5' - 6"

10

' - 0

"5

' - 5

"

PODIUM EDGEABOVE

PODIUM EDGEABOVE

28' - 11"

2' - 10"

ENTRANCE(SHADED BY

AWNING)

10' SETBACK

15' STO

RM E

SMT.

STANDPIPE

STANDPIPE

FIRE PUMPROOM

10' SETBACK

ENTRANCES

(SHADED BYAWNING)474.0

ELEV. 2

ELEV. 2CNTL RM

FITNESS ONDEMAND

H

F

E

C

J

B

2 3 4 5 6 7 8 9

A

D

G

L

11.11.4

K

1.3

B.1

2.1 111.21 10

MENSRR

WOMENSRR

MAINTENANCEROOM

5 SP

1 SP

2 SP

19

5' -

1"

0' -

2 3

/4

"2

9' -

8 3

/4

"0

' - 3

1/

2"

66

' - 1

1"

6' - 1" 9' - 0" 9' - 0" 9' - 0"

17

' - 6

"

9' - 0"

9' - 0"

17

' - 1

0 3

/4

"

120.00°

9' - 3" 31' - 3 1/2" 95' - 5" 6' - 9" 0' - 4" 2' - 8 1/2" 36' - 0" 2' - 8 1/2"0' - 1" 32' - 3 1/2" 41' - 0"

274' - 4 1/2"

0' -

1"

15

' - 4

1/

2"

12

' - 2

"

21

' - 5

1/

2"

0' -

5 1

/2

"0

' - 1

"2

6' -

0"

0' -

1"

25

' - 6

1/

2"

0' -

5 1

/2

"0

' - 1

"2

0' -

4"

0' -

1"

19

' - 1

0 1

/2

"0

' - 5

1/

2"

0' -

1"

20

' - 6

"3

9' -

2"

19

5' -

1"

6' - 4"

13' - 10" 0' - 1" 11' - 8 1/2" 9' - 2" 6' - 8" 5' - 2" 113' - 3" 64' - 2" 16' - 4" 2' - 10"

263' - 7 1/2"

2' - 0" 0' - 10"

POOLEQUIPMENT

ROOM

472.87

472.87

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

8/

31

/2

01

6 9

:42

:41

AM

A4.1

CWS

03/17/16

BAT

MEM

13-1926

LEVEL 1 OVERALL FLOORPLAN

WE

ST

5T

H S

TR

EE

T

13

01

W. 5

TH

ST

.A

U ST

IN, T

X 7

87

03

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

08/15/16

08/15/16

476.1 FFE 3/32" = 1'-0"1 LEVEL 1 OVERALL FLOOR PLAN

1

No. Revision Date

1 REV 1 Date 1

Page 46: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

Level 10' - 0"

Level 212' - 0"

Level 323' - 8 1/2"

Level 435' - 4 1/4"

Level 547' - 0"

Level 658' - 7 3/4"

Roof68' - 8"

10

' SE

TB

AC

K

8' S

ET

BA

CK

476.1 FFE

488.1 FFE

499.8 FFE

511.5 FFE

523.1 FFE

534.7 FFE

S9

S9

S9

S9

S9

S9

S9

S9

S9

S9

S1

S1

S9 S1

S1

S1

S1

S1

S1

S1

S2

S2

S2S12

S15S17

S18

C1S5 S4

S12

S12

S25

15

' ST

OR

M E

SM

T

04 07 05 06 08 01 09 03 02

1A5.4

2A5.4

1A5.4A

2A5.4A

1A5.4B

2A5.4B

1A5.4C

2A5.4C

48' HEIGHT LIMIT

7.2

% O

F H

T. L

IMIT

2' -

6"

48

' - 0

" F

RO

M A

VG

. GR

AD

E

73

' - 8

" T

OP

OF

PA

RA

PE

T

Level 10' - 0"

Level 212' - 0"

Level 323' - 8 1/2"

Level 435' - 4 1/4"

Level 547' - 0"

Level 658' - 7 3/4"

Roof68' - 8"

8' S

ET

BA

CK

15

' ST

OR

M E

SM

T

476.1 FFE

488.1 FFE

499.8 FFE

511.5 FFE

523.1 FFE

534.7 FFE

S1

S1

S1

S1

S1

S23

S22

S22

S22

S22

S22

S1

S1

S1

S1 S2

S20

S21

10

' SE

TB

AC

K

04 09 03 01 08 07

2A5.4D

3A5.4D

4A5.4D

1A5.4E

2A5.4E

4A5.4E

1A5.4D

S9

S2

S2

S2

S2

73

' - 8

" T

OP

OF

PA

RA

PE

T

3A5.4E

EXHAUST VENT

MATERIAL LEGEND

STUCCO (COLOR 1)01

STUCCO (COLOR 2)02

03

METAL PANELS05

06

ADDRESS NUMBERS ATLEAST 8" HIGH MUST BEVISIBLE FROM THE STREET.

09

THIN STONE VENEER

07

THIN BRICK VENEER

08

07

GLASS RAILING

HORIZONTAL RAILING

FIBER CEMENT PANELS

04 FIBER CEMENT CONCRETE PANELS

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

8/

31

/2

01

6 9

:48

:42

AM

A4.8

CWS

03/17/16

BAT

MEM

13-1926

NORTH & SOUTH EXTERIORELEVATIONS

WE

ST

5T

H S

TR

EE

T

13

01

W. 5

TH

ST

.A

U ST

IN, T

X 7

87

03

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

08/31/16

08/15/16

3/32" = 1'-0"1 NORTH ELEVATION

3/32" = 1'-0"2 SOUTH ELEVATION

1

No. Revision Date

1 REV 1 Date 1

1

Page 47: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

MATERIAL LEGEND

STUCCO (COLOR 1)01

STUCCO (COLOR 2)02

03

METAL PANELS05

06

ADDRESS NUMBERS ATLEAST 8" HIGH MUST BEVISIBLE FROM THE STREET.

09

THIN STONE VENEER

07

THIN BRICK VENEER

08

07

GLASS RAILING

HORIZONTAL RAILING

FIBER CEMENT PANELS

04 FIBER CEMENT CONCRETE PANELS

Level 10' - 0"

Level 212' - 0"

Level 323' - 8 1/2"

Level 435' - 4 1/4"

Level 547' - 0"

Level 658' - 7 3/4"

Roof68' - 8"

17

' SE

TB

AC

K

30

' SE

TB

AC

K

20

' SE

TB

AC

K

AT

&T E

SM

T.

476.1 FFE

488.1 FFE

499.8 FFE

511.5 FFE

523.1 FFE

534.7 FFE

S1

S1

S1

S1

S1

S1

S1

S1

S6

S19

S19

S19

S19

S19

S19

07 03 08 05

1A5.4F

2A5.4F

3A5.4F

4A5.4F

1A5.4G

2A5.4G

3A5.4G

4A5.4G

1A5.4H

2A5.4H

48' HEIGHTLIMIT

7.2

% O

F H

T. L

IMIT

2' -

6"

48

' - 0

" A

BO

VE

AV

G. G

RA

DE

73

' - 8

" T

OP

OF

PA

RA

PE

T

1A5.3A

EXHAUST VENT

Level 10' - 0"

Level 212' - 0"

Level 323' - 8 1/2"

Level 435' - 4 1/4"

Level 547' - 0"

Level 658' - 7 3/4"

Roof68' - 8"

17

' SE

TB

AC

K

30

' SE

TB

AC

K

20

' SE

TB

AC

K

ANGLES BACK

476.1 FFE

488.1 FFE

499.8 FFE

511.5 FFE

523.1 FFE

534.7 FFE

S23

S22

S22

S22

S22

S22

S1

S1

S1

S3

AWNING

AWNING

05 0706 02 04 03 01

3A5.4H

4A5.4H

1A5.4J

2A5.4J

3A5.4J

4A5.4J

1A5.4K

48

' - 0

" F

RO

M A

VG

. GR

AD

E

7.2

% O

F H

T. L

IMIT

2' -

6"

73

' - 8

" T

OP

OF

PA

RA

PE

T

48' HEIGHT LIMIT

INTAKE VENTS

INTAKE VENT

INTAKE VENT INTAKE VENT INTAKE VENT

04

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

8/

31

/2

01

6 9

:43

:11

AM

A4.8A

CWS

03/17/16

BAT

MEM

13-1926

EAST & WEST EXTERIORELEVATIONS

WE

ST

5T

H S

TR

EE

T

13

01

W. 5

TH

ST

.A

U ST

IN, T

X 7

87

03

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

08/15/16

08/15/16

3/32" = 1'-0"1 EAST ELEVATION

3/32" = 1'-0"2 WEST ELEVATION

1

No. Revision Date

1 REV 1 Date 1

Page 48: odenhughes-wpengine.netdna-ssl.com · 2012 International Building Code 2406.4 HAZARDOUS LOCATIONS. The following shall be considered specific hazardous locations requiring safety

Level 212' - 0"

Level 323' - 8 1/2"

Level 435' - 4 1/4"

Level 547' - 0"

Level 658' - 7 3/4"

Roof68' - 8"

488.1 FFE

499.8 FFE

511.5 FFE

523.1 FFE

534.7 FFE

S28

02 03 0709

2A5.4K

3A5.4K

1A5.4M

01

Level 212' - 0"

Level 323' - 8 1/2"

Level 435' - 4 1/4"

Level 547' - 0"

Level 658' - 7 3/4"

Roof68' - 8"

488.1 FFE

499.8 FFE

511.5 FFE

523.1 FFE

534.7 FFE

02 03 01 09

2A5.4M

3A5.4M

4A5.4M

Level 212' - 0"

Level 323' - 8 1/2"

Level 435' - 4 1/4"

Level 547' - 0"

Level 658' - 7 3/4"

Roof68' - 8"

488.1 FFE

499.8 FFE

511.5 FFE

523.1 FFE

534.7 FFE

02 03 01 09

Level 212' - 0"

Level 323' - 8 1/2"

Level 435' - 4 1/4"

Level 547' - 0"

Level 658' - 7 3/4"

Roof68' - 8"

488.1 FFE

499.8 FFE

511.5 FFE

523.1 FFE

534.7 FFE

03 09

5A5.4M

04

MATERIAL LEGEND

STUCCO (COLOR 1)01

STUCCO (COLOR 2)02

03

METAL PANELS05

06

ADDRESS NUMBERS ATLEAST 8" HIGH MUST BEVISIBLE FROM THE STREET.

09

THIN STONE VENEER

07

THIN BRICK VENEER

08

07

GLASS RAILING

HORIZONTAL RAILING

FIBER CEMENT PANELS

04 FIBER CEMENT CONCRETE PANELS

ISSUED FOR PERMIT

ISSUED FOR BID

ISSUED FOR CONSTRUCTION

DATE

DESCRIPTION

SHEET

DRAWN BY:

CHECKED BY:

PROJECT #:

8/

31

/2

01

6 9

:43

:15

AM

A4.8B

CWS

03/17/16

BAT

MEM

13-1926

COURTYARD EXTERIORELEVATIONS

WE

ST

5T

H S

TR

EE

T

13

01

W. 5

TH

ST

.A

U ST

IN, T

X 7

87

03

9606 NORTH MOPACEXPRESSWAY, SUITE 500,

AUSTIN TX 78759

08/31/16

08/15/16

3/32" = 1'-0"1 NORTH COURTYARD ELEVATION

3/32" = 1'-0"2 WEST COURTYARD ELEVATION 3/32" = 1'-0"3 EAST COURTYARD ELEVATION

3/32" = 1'-0"4 SOUTH COURTYARD ELEVATION

1

1

No. Revision Date

1 REV 1 Date 1