REPORT NO: OHA/HYG/BOBT/2019
PAGE 1 of 18
REVISION: 0
REV DATE: 2021/10/09
DATE OF REPORT: 2019/10/09
DATE OF ISSUE: 2019/10/11
SIGNATURE OH:
OCCUPATIONAL HYGIENE SURVEY
PREPARED FOR
BONA ONCE BONA TWICE DRUMS CC
This survey was conducted by:
Name: O Nkunkwane Signature:___
This survey was overseen by:
Name: R Gräbe Signature:___
FROM
SHE GROUP
OH0023
REPORT NO: OHA/HYG/BOBT/2019
PAGE 2 of 18
REVISION: 0
REV DATE: 2021/10/09
DATE OF REPORT: 2019/10/09
DATE OF ISSUE: 2019/10/11
SIGNATURE OH:
The Manager
Bona Once Bona Twice Drums CC
20 Phoenix Road North
Golden Springs
Selection Park
Springs
Tel: 011 363 1109
E-mail: [email protected]
Attention: S Kunene
REPORT ON OCCUPATIONAL HYGIENE SURVEY
Attached please find the following documents:
1. Comprehensive report on the above-mentioned survey conducted during October
2019 for the assessment of employee’s possible exposure to chemical and physical
stress factors as required.
It is a pleasure rendering our services to your Company. Should you have any queries with
regard to the attached report, please do not hesitate to contact us.
We look forward to the next opportunity of being of service to you.
s sincerely
Rynhard Gräbe
Occupational Hygienist
REPORT NO: OHA/HYG/BOBT/2019
PAGE 3 of 18
REVISION: 0
REV DATE: 2021/10/09
DATE OF REPORT: 2019/10/09
DATE OF ISSUE: 2019/10/11
SIGNATURE OH:
EXECUTIVE SUMMARY
It is important to recognise that this Survey can only be effective if the recommendations in this
report are implemented in conjunction with your integrated management system. Without
proper management the implementation recommendations will not succeed.
The inhalation of Hazardous Chemical Substances (HCS) can cause serious diseases. These
diseases usually become apparent only some years after exposure to HCS and sometimes not
until 40 or more years after the first exposure.
Diseases may result from:
Inhalation: HCS can be breathed in. Inhalation is the most common source of exposure to
HCS.
The exposure to noise levels in excess of 85dB(A) can cause noise induced hearing loss. These
diseases usually become apparent only some years after exposure to noise
Noise induced hearing loss may result from:
Continuous or intermitted exposure to noise levels in excess of 85dB(A).
Ventilation:
Poor or unventilated areas may lead to employees experiencing over exposure to gases.
Ergonomics:
Ergonomics is the scientific discipline concerned with the understanding of interactions
among humans and other elements of a system, and other elements of a system, and the
profession that applies theory, principles, data and methods to design in order to optimise
human wellbeing and overall systems performance .ergonomists contribute to the design
and evaluation of tasks, jobs, products, environments and systems in order to make them
compatible with the needs, abilities limitations of people
The approach of ergonomics is to optimise the user –interface, the work organisation and the
environment to achieve optimum human machine integration. Ergonomics is classified into 3
main domains:
Physical
Organisational
Cognitive
The need for ergonomics is clear, injuries rates are on the increase, especially for ergonomic –
related injuries, despite the increase in technology that is designed to help reduce the rates of
injuries
REPORT NO: OHA/HYG/BOBT/2019
PAGE 4 of 18
REVISION: 0
REV DATE: 2021/10/09
DATE OF REPORT: 2019/10/09
DATE OF ISSUE: 2019/10/11
SIGNATURE OH:
Rynhard Gräbe
Occupational Hygienist
REPORT NO: OHA/HYG/BOBT/2019
PAGE 5 of 18
REVISION: 0
REV DATE: 2021/10/09
DATE OF REPORT: 2019/10/09
DATE OF ISSUE: 2019/10/11
SIGNATURE OH:
INDEX TO THIS PROGRAMME
1. Introductory and special notes.
2. Legal References
3. Confidentiality
4. Definitions & Abbreviations
5. Concern details.
6. General Concern Information
7. Legal Standards
8. Strategy Profile
9. Legal Compliance
10. Compliance Standards
11. Results, Evaluation and Recommendations
REPORT NO: OHA/HYG/BOBT/2019
PAGE 6 of 18
REVISION: 0
REV DATE: 2021/10/09
DATE OF REPORT: 2019/10/09
DATE OF ISSUE: 2019/10/11
SIGNATURE OH:
1. INTRODUCTORY AND SPECIAL NOTES
1.1 The purpose of the survey was:
1.1.1 To establish the presence of chemical substances as well as the exposure levels of
employee’s.
1.1.2 Establish a database for future references.
1.1.3 Evaluate the necessity of remedial actions;
1.2 COLOR CODE
1.2.1 All mandatory references applicable to specific factory / premises activities are
printed in red.
1.2.2 All guideline and reference notes are printed in blue and remains part of the official
document.
2. LEGAL REFERENCES
2.1 Occupational Health and Safety Act, No. 85 of 1993 (as amended) and the
Regulations promulgated under this Act;
2.2 NIOSH: Occupational Exposure Sampling Strategy Manual.
2.3 NIOSH HCS Sampling Methodology Edition 3.
2.4 ISO/IEC 17020:2012, Clause 7.1.
2.5 SANS 10083:2013.
2.6 SANS 10014 Part 2.
3. CONFIDENTIALITY
3.1 All work performed by SHE Management is treated as confidential.
SHE Management are required to submit information relating to results found to DoL in
accordance with Annexure 3 of the AIA accreditation procedure. This report does not
require us to provide client name or details, but does require some basic industry
related information. We are happy to provide you with a copy of the report for your
records prior to release to DoL.
REPORT NO: OHA/HYG/BOBT/2019
PAGE 7 of 18
REVISION: 0
REV DATE: 2021/10/09
DATE OF REPORT: 2019/10/09
DATE OF ISSUE: 2019/10/11
SIGNATURE OH:
4. DEFINITIONS & ABBREVIATIONS
In this report, words, terminology and phrases used, have the meanings assigned to
them in the relevant legislation and legally prescribed codes listed above.
Approved Inspection
Authority
An approved inspection authority for the monitoring of
asbestos concentrations in the air
Respirator Zone
An area where the concentration of an airborne
hazardous chemical substance exceeds the
recommended limit for that substance
Respiratory Protective
Equipment
A device which is worn over at least the mouth and
nose to prevent the inhalation of airborne hazardous
chemical substances and which is of a type, or
conforms to a standard approved by the minister
The Act The Occupational Health and Safety Act, 1993 (act
No. 85 of 1993).
TWA Time Weighted Average
CONC. Pollutant Concentration
OEL Occupational Exposure Limit
AQI
Air Quality Index
SANS South African National Standards
REPORT NO: OHA/HYG/BOBT/2019
PAGE 8 of 18
REVISION: 0
REV DATE: 2021/10/09
DATE OF REPORT: 2019/10/09
DATE OF ISSUE: 2019/10/11
SIGNATURE OH:
5. CONCERN DETAILS
Name of Concern: Bona Once Bona Twice Drums CC
Workroom Environmental Surveillance
Guideline Reference no.: OHA/HYG/BOBT/2019
Production Processes: Reconditioning and Manufacturing of Drums
Safety Manager: I Kunene Jnr
Postal Address: PO Box 125 Kwathema, 1563
Tel. No.:
E – mail No.:
011 363 1109
Magisterial District: Springs
Contact Official: S Kunene
Tel. No.: 011 363 1109
Effective Date: 2019/10/09
Revision Date: 2021/10/09
6. GENERAL CONCERN INFORMATION
6.1 Locality.
The concern is situated in 20 Phoenix North Road, Springs in the Gauteng Province.
6.2 Concern activities
The concern is a reconditioning and manufacturing of drums site and is administrated
under the Occupational Health & Safety Act 85 of 1993.
7. STANDARDS
Survey was done taking into account the Regulations promulgated under the
Occupational Health and Safety, No. Act 85 of 1993 (as amended).
REPORT NO: OHA/HYG/BOBT/2019
PAGE 9 of 18
REVISION: 0
REV DATE: 2021/10/09
DATE OF REPORT: 2019/10/09
DATE OF ISSUE: 2019/10/11
SIGNATURE OH:
8. STRATEGY PROFILE
8.1 Measuring Procedure – Airborne Pollutants
- Personal gravimetric samples were taken with the sampling trains running
continuously during the course of the normal working shift.
- The pumps were calibrated, with the sampling heads in line, at 2.0 liters per minute
using an electronic calibrator (absolute volume displacement method). A calibration
authority calibrates the calibrator annually.
- At the end of each sampling shift the volume flow of each sampling train was
checked, using the same method as for setting the flow rate prior to sampling. Only
samples from sampling trains, which had a volume flow rate within the acceptable
margin of ± 5 % of the calibrated, flow rate, were included in the assessment;
- The mass of the filters was determined prior to sampling. After sampling the mass of
the filters and the collected airborne particulate had been ascertained and the time-
weighted-average (TWA) concentration in milligrams per cubic meter calculated;
- The weighing of filters was in accordance with international accepted norms;
- Samples were transported in a carrying case similar to a vanity case with the handle
on top of the lid and fully lined with low-density foam rubber. The case is clearly
marked “Handle with Care” and “This Side Up”. The case is designed to prevent
inadvertent opening whilst being handled or when in transit;
8.2 Measuring Procedure – Noise.
Noise zones
- Suspected noise risk areas were scanned and noise zones established;
- The sound pressure levels (LAr,T) were measured by scanning each zone. Where
impulse noise was present the instrument was set to accommodate impulses;
- Salient noise sources were measured individually at a distance of 2 m away with the
microphone pointing towards the source;
SANS Code 10083 was followed as a general strategy guide.
- Where noisy equipment is not used continuously, measurements were taken when the
equipment was operational and when the equipment was not operational;
- Time interval noise intensities were observed to be accommodated in calculations of
personal exposure levels, if not substantiated by personal dosimeter readings
REPORT NO: OHA/HYG/BOBT/2019
PAGE 10 of 18
REVISION: 0
REV DATE: 2021/10/09
DATE OF REPORT: 2019/10/09
DATE OF ISSUE: 2019/10/11
SIGNATURE OH:
8.3 Illumination
- The one-meter grid method recommended in SANS code 10114: Part one - 2005 was
adopted as the general guide;
- Faulty and/or dirty illuminants were observed;
- Obvious dark spots were observed and illumination levels measured;
- Stroboscopic effects and illuminants with glare were observed
8.4 Measuring Procedure – Ventilation
- Offices were assessed against the requirements of the National Building Regulations;
- Fresh air supply and conditioning of air were assessed as required under SANS 10400:
2008.
9. MEASURING EQUIPMENT
9.1 Measuring Procedure – Airborne Particulate
- Intrinsically safe self-compensating gravimetric sampling pumps were used;
- 37mm Diameter G-x sampling cassettes (sampling heads) loaded with 37mm
diameter, 0.8 micrometer pore size Gelman GN-4 mix cellulose ester filters completed
the sampling trains;
- Weighing of filters was done on a five - decimal - point (g) analytical balance;
- A calibration authority calibrates the balance annually
9.2 Noise (SANS 10083:2013)
- A continuous integrating sound level meter capable of determining the equivalent A
- weighted sound pressure level (LAr, T) was used;
- The accuracy of the instrument complies with the requirements for a type one
classification as per IEC Publication 651;
- The instrument is capable of displaying the A - weighted sound pressure level
including the I-time weighting characteristic (impulses) when applicable;
- An acoustic source designed for use with the meter’s microphone and having a
single frequency sound output was used to calibrate the meter immediately prior to
use and to check the meter after being used;
- A calibration authority calibrates both the meter and the acoustic source annually
REPORT NO: OHA/HYG/BOBT/2019
PAGE 11 of 18
REVISION: 0
REV DATE: 2021/10/09
DATE OF REPORT: 2019/10/09
DATE OF ISSUE: 2019/10/11
SIGNATURE OH:
9.3 Illumination SANS 10114:1 - 2005
- An ordinary lux meter was used to measure the illumination levels. A calibration
authority calibrates the instrument used annually.
9.4 Ventilation
- A Hot Wire Anemometer was used to measure airflow.
- A calibration authority calibrates the instrument used annually.
- The following sampling equipment were used:
10. STANDARDS
10.1 Standards – Airborne Particulate
- The limits listed in table 1 & 2 in the Hazardous Chemical Substances Regulations
promulgated under the Occupational Health and Safety Act 85 of 1993 (as
amended)
10.2 Noise
- SANS code 10083:2013 for The Measurement and Assessment of Occupational Noise
for Hearing Conservation Purposes;
10.3 Illumination
- SANS code 10114: Part one - 2005
10.4 Ventilation
- SANS 10400:2008
REPORT NO: OHA/HYG/BOBT/2019
PAGE 12 of 18
REVISION: 0
REV DATE: 2021/10/09
DATE OF REPORT: 2019/10/09
DATE OF ISSUE: 2019/10/11
SIGNATURE OH:
11. RESULTS, EVALUATION AND RECOMMENDATIONS 11.1 Airborne Particulate (Calibrator 1137; 137-S was used for calibration)
Sample Locality
TWA
CONC.
(mg/m³)
POLL.
CONC.
(mg/m³)
OEL
(mg/m³)
POLL.
CONC.
(mg/m³)
OEL
(mg/m³)
Calc.
AQI *
Date
PNOC = 100%
P. Diale - Spray
painting(Titan)filter=004 2.61 2.61 10 - - 0.26
Oct
2019
S. Nkosi - Spraypainting
(Newco)filter=003 2.19 2.19 10 - - 0.22
J. Makhubele - grinder
operator(Titan)filter=012 3.67 3.67 10 - - 0.37
Recommendations:
Exposure records should be retained for 40 years.
REPORT NO: OHA/HYG/BOBT/2019
PAGE 13 of 18
REVISION: 0
REV DATE: 2021/10/09
DATE OF REPORT: 2019/10/09
DATE OF ISSUE: 2019/10/11
SIGNATURE OH:
11.2 Noise (Sound level meter no sn JN2070068)
Working Area / Equipment: No.
Area
LAr,8h
[dB A)]
Standard
db(A)
Comply
Y/N
Noise
zone
Reconditioning building -
Open Top section -
Male toilets - 79.0 85 Y N
Paint booth area - 88.0 85 N Y
Expander drum 1 103.0 85 N Y
Body roller 2 90.1 85 N Y
Chimer 3 102.0 85 N Y
Curler 4 100.0 85 N Y
Tester 5 87.1 85 N Y
Lid Press machine 6 90.1 85 N Y
Lid closer 7 89.0 85 N Y
Cutting machine - 83.8 85 Y N
Curler - 99.3 85 N Y
Tall drum cutter - 100.1 85 N Y
Titans section -
Grinder - 106.0 85 N Y
Chyma - 96.3 85 N Y
Expander - 93.1 85 N Y
Pre-flush - 83.1 85 Y N
Leak tester - 94.1 85 N Y
Washing bay - 84.1 85 Y N
Vacuum station - 83.2 85 Y N
Dispatch - 84.8 85 Y N
REPORT NO: OHA/HYG/BOBT/2019
PAGE 14 of 18
REVISION: 0
REV DATE: 2021/10/09
DATE OF REPORT: 2019/10/09
DATE OF ISSUE: 2019/10/11
SIGNATURE OH:
Working Area / Equipment: No.
Area
LAr,8h
[dB A)]
Standard
db(A)
Comply
Y/N
Noise
zone
Compressor - 87.3 85 N Y
Manufacturing building - - - - -
Welder -- 99.1 85 N Y
Flange curler - 81.8 85 Y N
Rolling hoop - 90.1 85 N Y
Seamer - 104.1 85 N Y
Testing station - 101.2 85 N Y
Paint booth - 85.3 85 N Y
Oven - 80.2 85 Y N
Cooler tower - 82.0 85 Y Y
Top painter - 91.0 85 N Y
Store - 85.3 85 N Y
Screen painting - 86.3 85 N Y
S.Nkosi-spraypainting (Newco) - 86.9 85 N -
J. Makhubele-grinder
operator(Titan)
- 101.2 85 N -
Observations:
All employees have been issued with HPE (hearing protective equipment).
Evaluations:
Some of the measured noise levels were above 82dB (A).
Recommendations:
All areas where the noise levels were above 82dB (A), should be demarcated as noise zones
and the wearing of PPE should be compulsory near equipment.
Exposure records should be retained for 40 years.
REPORT NO: OHA/HYG/BOBT/2019
PAGE 15 of 18
REVISION: 0
REV DATE: 2021/10/09
DATE OF REPORT: 2019/10/09
DATE OF ISSUE: 2019/10/11
SIGNATURE OH:
11.3 Illumination (L0110052)
* Illumination is not included in the SANAS scope of accreditation and is not a requirement under the
Department of Labour.
Working area / Equipment: No.
Measured
Level
Lux
Standard
Lux
Comply
Y/N Remarks
Office
Siphamandla workstation - 201 500 Y -
Ishmael snr workstation - 561 500 Y -
Mimi workstation - 699 500 Y -
Floor - 342 100 Y -
Boardroom - 303 300 Y -
Floor - 284 100 Y -
Kitchen - 350 100 Y -
Floor - 301 100 Y -
Toilets - 541 100 Y -
Floor - 511 100 Y -
Canteen - 432 100 Y -
Floor - 411 100 Y -
Reconditioning building - -
Open Top section - -
Male toilets - 209 100 Y -
Floor - 201 100 Y -
Paint booth area - 1986 200 Y -
Expander drum - 821 100 Y -
Body roller - 889 100 Y -
Chyma - 1988 100 Y -
REPORT NO: OHA/HYG/BOBT/2019
PAGE 16 of 18
REVISION: 0
REV DATE: 2021/10/09
DATE OF REPORT: 2019/10/09
DATE OF ISSUE: 2019/10/11
SIGNATURE OH:
Working area / Equipment: No.
Measured
Level
Lux
Standard
Lux
Comply
Y/N Remarks
Curler - 1901 100 Y -
Tester 901 100 Y -
Lid Press machine - 912 100 Y -
Lid closer - 994 100 Y -
Titans section -
Chyma - 1221 100 Y -
Expander - `1341 100 Y -
Pre-flush - 1243 100 Y -
Leak tester - 1892 100 Y -
Washing bay - 1983 100 Y -
Vacuum station - 1980 100 Y -
Dispatch - 1989 100 Y -
Manufacturing building -
Welder - 301 150 Y -
Flange curler - 312 100 Y -
Rolling hoop - 314 100 Y -
Seamer - 335 100 Y -
Testing station - 1943 100 Y -
Paint booth - 399 100 Y -
Oven - 312 100 Y -
Cooler tower - 199 100 Y -
Top painter - 202 200 Y -
Store - 603 100 Y -
REPORT NO: OHA/HYG/BOBT/2019
PAGE 17 of 18
REVISION: 0
REV DATE: 2021/10/09
DATE OF REPORT: 2019/10/09
DATE OF ISSUE: 2019/10/11
SIGNATURE OH:
Working area / Equipment: No.
Measured
Level
Lux
Standard
Lux
Comply
Y/N Remarks
Screen painting - 501 200 Y -
Observation:
Lights were found to be very well maintained. Work is done only during the day shift.
Proper lighting is installed at ficility.
Evaluation:
All measured illumination levels were above the relevant standards.
11.4 Ventilation
* Illumination is not included in the SANAS scope of accreditation and is not a requirement under the
Department of Labour.
Locality
Floor/window
ration
%
Standard
%
Air supply
(L/min)
Standard
(L/min/person)
Comply
(Y/N)
Boardroom 3.69 5 - - N
Office 2.16 5 - - N
Reconditioning
building
- - 389 5 Y
Reconditioning
building next to
compressor
- - 1868 5 Y
Reconditioning
building next to
grinding
- - 2463 5 y
Observations:
Measurements were taken where air-conditioners have been installed. Rooms without air-
conditioners were evaluated against the National Building Regulation.
Evaluation:
Only two rooms did not comply with the relevant standards.
Recommendations:
Rooms where the ration between windows and floors do not exceed 5%, should be fitted
with air-conditioners or additional windows.
REPORT NO: OHA/HYG/BOBT/2019
PAGE 18 of 18
REVISION: 0
REV DATE: 2021/10/09
DATE OF REPORT: 2019/10/09
DATE OF ISSUE: 2019/10/11
SIGNATURE OH:
Rynhard Gräbe
Occupational Hygienist