Upload
ddadara
View
18
Download
4
Embed Size (px)
DESCRIPTION
N2&O2 generators OXYMAT
Citation preview
COMPRESSED AIR
Maximum operating pressure 8 bar (g)
Operating temperature 10-40C
Minimum inlet pressure 7 bar (g)
Dew point max +3C
Air quality ISO Specification ISO 8573.1:2001.2.4.1
OXYMAT OXYGEN GENERATORS
Prod. No. Name Description Analogue Inputs IP Class
DCP1 25001 Display Control 1 2 lines text display, numeric keys, Alarm indication 1 x product pressure, 1 x oxygen readings IP 54
IPC 25010 Intellicontrol Touch screen 7 colour, wide screen, alarm indication and trends 1 x product pressure, 1 x oxygen readings, 2 x column pressure IP 54
CONTROL PANELS FOR STANDARD SOLUTIONS
PURITY MONITORING AND CONTROL (ADD-ON`S FOR MAIN CONTROL PANEL)
WORLDWIDE MANUFACTURER OF PSA GENERATORS
model Oxymat O500 ECO v1
Oxygen purity rate [%, ppm] 90% 94% 95%
Sm/hour (*) 28.89 25.71 24.55
Air feed [m/min.] F.A.D. at min. 7 bar 4.79 4.79 4.79
Power consumption generator [kW] 0.1 0.1 0.1
Oxygen outlet pressure [bar] (g) (**) 4 4 4
Minimum Oxygen receiver tank [litres] 1000 1000 1000
Minimum Air receiver tank [litres] 1000 1000 1000
Hose connection [inches] 1 1/2 1 1/2 1 1/2
Dimensions L x W x H [cm] 200x125x240 200x125x240 200x125x240
Shipping dimensions L x W x H [cm] 220x145x265 220x145x265 220x145x265
Maintenance area L x W x H [cm] 220x195x260 220x195x260 220x195x260
Weight [kg] 1,800 1,800 1,800
92%
27.81
4.79
0.1
4
1000
1000
1 1/2
200x125x240
220x145x265
220x195x260
1,800
93%
27.00
4.79
0.1
4
1000
1000
1 1/2
200x125x240
220x145x265
220x195x260
1,800
Prod. No. Name Description Valid for control IP Class
OM1 26101 Oxygen monitor for oxygen generators
Range 0.1-100% Includes alarm function (through control) All IP 22
OM1E 26121 Oxygen monitor for oxygen generators + output
As OM1 plus 2x analogue output 4-20mA representing pressure and purity All IP 22
PCON2 2600 Purity control II
Purges product outside valid purity range. Placed after product tank. All -
PCON1 26001 Purity control I
Purges product outside valid purity range. Placed before product tank. All -
ISO 9001 ISO 13485
PED 97/23/EC MDD 93/42/EC
* All volumetric units: [Sm] 15 gr. 981 mbar ** Modification possible Note: Capacity of the plant is stated at 30C ambient air temperature. Variance5%