Western Medica 800-783-78902
O2 Advantage® Oxygen Conserving DeviceThe Western Medica O2 Advantage Conserving Device takesportable oxygen where it’s never been before. It is the onlyconserver that “learns” the patient’s breathing patterns, thencustomizes the amount of oxygen delivered with each breath.While delivering the prescribed liter flow, the O2 Advantageconserves enough oxygen to significantly reduce cylinderinventory and fill cost. Patients can take the O2 Advantage moreplaces than ever thanks to its four attractive carrying cases.
n Provides therapy and conserves oxygen by deliveringprescribed liter flow for a set percentage of every inhalation period
n Monitors breathing rate and adjusts O2 delivery based onpatient’s activity level
n Eliminates excessive oxygen blastsn Conserves gas in cylinders and liquid oxygen systemsn Functions with standard regulators up to 80 psi
delivery pressuren User can switch to continuous flow without
disconnecting conservern Automatically switches to continuous flow during breath
detection alarm phasen Audio and visual low battery indication
02 Advantage Specifications
Model CD1-2Size 6-1/29 x 3-1/49 x 1-3/89
Weight 13.5 ozPower 2 AA Alkaline BatteriesBattery 50 hr Average Duration @ 20 bpmAdapter AC 115 VAC 60HzLPM For use with prescriptions up to 5 LPM
O2 Advantage® Electronic Oxygen Conserving Device
Features:
Unit is shipped with 48 dual lumen cannula, 129 supply tube,2 AA alkaline batteries and AC adapter.
CD1-2 Oxygen Conserving Device with an OPA-830 compact click-style regulator on a M6A cylinder and PX-1035 nylon duffel sack.
CD1-2Variable DemandOxygen Conserving Device
3
OPC Conserving Regulator
OPC Conserving RegulatorThe OPC Conserving Regulator is perfect for active patients whorequire a portable, lightweight system. Utilizing Western’s uniquedesign, the OPC provides compact performance in an oxygenconserving regulator by delivering prescribed liter flow ondemand. Constructed with an aluminum body and brass high-pressure chamber, it’s safe, simple to use and affordable. The OPCConserving Regulator, like all Western products, meets exactingstandards for performance and reliability.
OPC-830Conserving Regulator
n Regulator and pneumatic conserving device combined intoone unit
n Provides therapy and conserves oxygen by deliveringprescribed liter flow during inhalation period only
n User can switch to continuous flow without disconnecting unit
n Compact aluminum body with brass inlet chambern Dial-in flow controln Maximum inlet pressure 3000 psin Sintered filter for additional safety and to extend
regulator lifen Internal reseating relief valve protects against
overpressurizationn 1-1/29 diameter gauge
Features:
OPC Specifications
Model OPC-830Size 4-1/29 x 39 x 1-1/29
Weight 22 ozLPM 1/2, 1, 2, 3, 4, 5
Unit is shipped with 48 dual lumen cannula.
Western Medica 800-783-7890
4 Western Medica 800-783-7890
Oxygen Conserver Carrying Packs
Duffel Sack – Nylon PX-1035Leather PX-1036
Day Pack – Nylon PX-1037Leather PX-1038
Mini Case w/Cart – Nylon Case PX-1032D/E Cart PX-1020
Padded Shoulder Straps PX-1039 are available to convert the Day Pack into a Back Pack.
n Stylish packs discreetly hold cylinder, regulator and O2 Advantage Conserving Device
n Pack fits the following portable aluminum cylinders:M4 (A), M6 (B), M6A (ML6), M7 or M9 (C)
n Packs include compartment for personal items
n Single Cart (PX-1020) holds one D or E size cylindern Dual Cart (HCC5-M) holds two D or E size cylindersn Mini Case attaches to gas cylinder or liquid systemn Carrying Packs easily attach to wheelchairsn For additional bags see page 8
Recommended Regulators:
Features:
XA Series Regulatorssee page 14 for details
OPA Series Regulatorssee page 12 for details
All-In-One Portable Oxygen Systems
XRA-3430 All-In-One System shown on a PX-1020 Cart with a CD1-2 O2 Advantage Conserver in a PX-1032 Mini Case
n Brass regulator assembly and aluminum oxygen cylinder
n Regulator assembly incorporates post valveand flow control device in a single unit
n Durable cover protects regulator assemblyn Built-in handle for portabilityn 1 1/29 diameter gaugen Transfillable through CGA-540 portn Can be used with O2 Advantage Oxygen
Conserving Devicen All-In-One systems are available filled
or emptyn Call Customer Service for availability
All-In-One Systems Feature:
Western Medica 800-783-7890 55
Western Medica 800-783-78906
99 x 39 • 1.8 lbs 11³⁄₄9 x 39 • 2.4 lbs 7³⁄₄9 x 4¹⁄₂9 • 2.8 lbs 99 x 4¹⁄₂9 • 3.1 lbs 10¹⁄₂9 x 4¹⁄₂9 • 3.5 lbsAluminum Cylinders 113 Liters • 2216 psi 164 Liters • 2216 psi 170 Liters • 2015 psi 198 Liters • 2015 psi 246 Liters • 2015 psiwith Valves 144/Pallet • 4.0 cu ft 144/Pallet • 5.8 cu ft 81/Pallet • 6.0 cu ft 81/Pallet • 7.0 cu ft 81/Pallet • 8.7 cu ft
Dual Control Valve CGA-870 PX-8704-1 PX-8700-1 PX-8705-1 PX-8707-1 PX-8701-1
Wrench Valve CGA-870 PX-8704-1W PX-8700-1W PX-8705-1W PX-8707-1W PX-8701-1W
Toggle Valve CGA-870 PX-8704-1T PX-8700-1T PX-8705-1T PX-8707-1T PX-8701-1T
Oxygen Cylinders and Accessories
M4 (A) M6A (ML6)M6 (B) M7 M9 (C)
MPV-870Dual Control Valve
MPV-872TToggle Valve
MPV-872Wrench Valve
w/MPV-4027 Seal
MPV-540Wing Knob Valve
Cylinder Valves (2216 psi)
MPV-540 Wing Knob Valve CGA-540
MPV-870 Dual Control Valve CGA-870
MPV-872 Wrench Valve CGA-870
MPV-872T Toggle Valve CGA-870
QUE-9001 CGA-540 Spigot Valve for M60 and M Aluminum Cylinders
Note: For 3000 psi valves add suffix “A” to model number.Example: MPV-872A.
Notes: 1. To order filled cylinders, replace -1 with -3 in Model Number. Example: PX-8704-1W becomes PX-8704-3W when filled.
2. Jumbo D cylinders are available on request.
3. Cylinders with CGA-540 valves are available on request.
4. Redesigned M6A (ML6), M7, M9 (C), D and E cylinders are 8 to 10% lighter in weight than previous models.
QUE-9001CGA-540 Spigot Valve
Post Valve Seals
MPV-4027 Post Valve Seal (Plastic Clip Dust Cover)MPV-4040 Post Valve Seal (Shrink Wrap Dust Cover)
n Aluminum cylinders are 40% lighter than steeln Cylinders are cleaned for medical oxygen servicen Safety paint protects cylinder sidewall and provides
heat detectionn Cylinder finish is easy to clean and maintainn Straight thread design eliminates thread damage and
provides positive seal
Medilux® Aluminum Cylinder Features:
Western Medica 800-783-7890 7
169 x 4¹⁄₂9 • 4.9 lbs 259 x 4¹⁄₂9• 7.3 lbs 23¹⁄₂9 x 7¹⁄₄9 • 22.5 lbs 36¹⁄₄9 x 89 • 40.1 lbs425 Liters • 2015 psi 679 Liters • 2015 psi 1699 Liters • 2216 psi 3454 Liters • 2216 psi81/Pallet • 15.0 cu ft 81/Pallet • 24.0 cu ft 42/Pallet • 60.0 cu ft 25/Pallet • 122.0 cu ft
PX-8702-1 PX-8703-1 PX-5405-1 PX-5406-1PX-8702-1W PX-8703-1W CGA-540 CGA-540
PX-8702-1T PX-8703-1T w/Spigot Valve w/Spigot Valve
519 x 99 • 113 lbs6500 Liters • 2015 psi20/Pallet • 228.0 cu ft
PX-5408-1PCGA-540 w/Spigot Valve
Pallet Quantities Only
E M60 Steel H Cylinder
Liter Meter
MT100 1/4 -2¹⁄₂ LPM Flow Measurement
MT200 1/2 - 8 LPM Flow Measurement
MT300 3 - 15 LPM Flow Measurement
Cylinder Wrenches
MCW-2B Metal WrenchMCW-2BC Metal Wrench w/Security Chain
MCW-3P Plastic WrenchMCW-3PC Plastic Wrench w/Security Chain
D M
Western Medica 800-783-78908
PX-1013(Bag only)
PX-1011(Bag only)
PX-1020
PX-1025 PX-1029 PX-1027
HCC5-M HCC1-M HCC2-M
MCC2MCC1PX-1034
HCC3-M
PX-1020 D or E 1HCC5-M D or E 2HCC1-M M60 or M 1HCC2-M M60, M or H 1HCC3-M M60, M or H 1MCC1 D or E 12MCC2 D or E 24
Cylinder Carts
Model Cylinder Capacity
PX-1025 C, D or E 6PX-1027 C, D or E 12PX-1029 M6 (B) 12PX-1034 D or E 40PX-1041 D or E 24
MCS C, D or E 1HCS-M H 1HCS2-M M60 or M 1
Cylinder Racks and Stands
Model Cylinder Capacity
PX-1011 Black Nylon Bag for C CylinderPX-1013 Black Nylon Bag for D Cylinder
Shoulder Packs
Model Cylinder
Cylinder Carts, Racks, Stands and Bags
HCS-MMCS
Western Medica 800-783-7890 9
TR-104 Oxygen AnalyzerMCP511 Vacuum Pump for TS9-10-12PK System OnlyCS-PK2 Vacuum Pump for TS9-5-3PK System OnlyMSH15580 Nitrogen Calibration Regulator for TR-104MSH15540 Oxygen Calibration Regulator for TR-104G-544A Contents Test GaugeMST-1 Aluminum Cylinder ThermometerCLM-1 Lot Number Label GunCL-1 Lot Number Labels (1250/Roll)A80024 Oxygen Cylinder LabelsA60019 Full, In-Use and Empty TagsMTT-1 Teflon Thread Tape 1/49 x 5209 RollLT-200 Leak Test 4 oz BottleMPV-4027 Post Valve Seals
Portable TransfillerThis portable system provides a convenient way of transfilling oxygen cylinders from a single supply source.
PX-2000 Fills CGA-870 from CGA-540PX-2001 Fills CGA-540 and CGA-870 from CGA-540
TR-104 Oxygen Analyzer
TS9-500PK and TS9-PKTransfill Accessories Kits Include:
CS-PK2 Vacuum Pump
TS9-10-12PK The TS9-10-12PK is a complete system designed for transfilling 12cylinders at a time from a supply bank of 10 large cylinders. This system includes:
TS9 Gas-To-Gas Oxygen Transfill Systems
MCP511 Vacuum Pump
WHSV-9-5ER Right Side 5 Station Supply Header w/Check Valves TSS-9-5M Left Side 5 Station Supply Header w/Check ValvesPF-63CV-24 249 Supply Side Pigtails w/Check ValvesMCP325 12 Cylinder Manifold CartRSM20 Pressure Control RegulatorPF-63HT-60 609 Supply-To-Fill PigtailVV200 Dual Vacuum Regulator AssemblyTS9-500PK Transfill Accessories Kit
TS9-5-3PK The TS9-5-3PK is a complete starter system designed for transfilling 3 cylinders at a time from a supply bank of 5 large cylinders. This system includes:
TSS-9-5 Supply Side Header w/Check Valves TSF-9-3 Fill Side Header w/Contents Gauges,
Restricters and Shut-Off Valves at Fill PortsPF-63CV-24 249 Supply Side Pigtails w/Check ValvesRSM20 Pressure Control RegulatorPF-63-870-24 249 Fill Side PigtailsPF-63HT-60 609 Supply-To-Fill PigtailVV100 Vacuum RegulatorTS9-PK Transfill Accessories KitPX-1025 Cylinder Rack (optional)
TS9 Transfill Systems Feature:
n Cost effective and safe filling of high pressure aluminum or steeloxygen cylinders up to 2000 psi
n A wide range of transfill system configurationsn The ability to upgrade systems as cylinder fill requirements increasen Detailed instructions for installation and operation including
documentation for FDA compliance
Western Medica 800-783-789010
MCP630 Cordless Rachet Gun 9.6 Volt – for opening and closing cylinder post valves. Kit includes rachet gun, 2 rechargable battery packs and charger,sockets for dual control, wrench and toggle valves, with carrying case.
MCP320 Cylinder manifold cart equipped with 20 fill stations.
MCP1000 Liquid-To-Gas Oxygen Transfill System
Western Medica 800-783-7890 11
The MCP System can be equipped with an optional manifold forfilling H cylinders. By adding the gas transfill manifold, smallorders are filled at liquid prices.
This unique cryogenic pump and vaporizer unitconverts liquid oxygen to high pressure gas.
TR-104 Oxygen Analyzer
Meets FDA requirements for analyzing USP oxygen cylinders. Unit features ± 0.1% accuracy, rechargeable internal power pack, recharger, aspirator and drying tube.
For calibration, order MSH15580 Nitrogen and MSH15540 Oxygen Regulators.
The redesigned MCP1000 is a palletized, fullyintegrated system for cost effective transfillingof oxygen cylinders. The system converts liquidoxygen to high pressure gas and evacuates andfills 10-40 cylinders at a time.
The new design conveniently locates a largercontrol panel on the front of the system. Thismakes it easier to read and operate whileminimizing space requirements. The MCP1000also includes a unique cryogenic conversionpump with vertical piston design, vaporizer unit,special transfill manifold, integrated clean aircompressor and vacuum pump assembly. Fromevacuation to cylinder refill Western’s MCP1000System delivers:
n Lower cylinder inventoriesn Lower filled cylinder costn Maximum control of oxygen supplyn 24 hour capabilityn Rapid fill timen Improved cylinder handling and labor
efficiency
With the MCP1000 aluminum or steel cylinderscan be filled at pressure settings up to 2650 psi.
Installation and training provided by Westernincludes system operation and guidance inmeeting FDA regulations.
Standard MCP1000 Systems Include:n Cryogenic Conversion Pump and
Vaporizer Unitn 140 Liter Supply Tankn Control Panel with easy-to-read Gaugesn 5 HP Air Compressor n 10 SCFM Vacuum Pumpn Cryogenic Transfill Hose with Relief Valvesn Hardware and Filling Accessories
MCP1000 Options:n Cylinder Cart with 20 Fill Stationsn H Cylinder Manifoldn TR-104 Oxygen Analyzern Gas Transfill Manifold
To meet specific fill demands, a variety of options are available. For additional details,design assistance and a cost per filled cylinderanalysis, call 800-783-7890.
Western Medica 800-783-789012
OPA Series Compact Click-Style Regulators
Oxygen OPA-510 1/64, 1/32, 1/16, 1/8, 1/4, 1/2, 3/4, 1, 1-1/2, 2 LPM 15 CGA-540 Nut and NippleOPA-520 1/4, 1/2, 1, 2, 3, 4, 6, 8, 10, 15 LPM 50 CGA-540 Nut and NippleOPA-810 1/64, 1/32, 1/16, 1/8, 1/4, 1/2, 3/4, 1, 1-1/2, 2 LPM 15 CGA-870 YokeOPA-820 1/4, 1/2, 1, 2, 3, 4, 6, 8, 10, 15 LPM 50 CGA-870 YokeOPA-830 1/2, 1, 2, 3, 4, 5 LPM 15 CGA-870 YokeOPA-850 1/2, 1, 2, 3, 4, 6, 8, 10, 15, 25 LPM 50 CGA-870 Yoke
Note: Regulators are available with chrome-plated brass bodies. Call Western for model number information.
Compact OPA Models
Gas Model Flow Settings Delivery Pressure Inlet Connection
Regulator Features:
n Compact aluminum body with brass inlet chamber
n Tested to CGA standards which includeignition testing
n Dial-in flow controln Maximum inlet pressure 3000 psin Sintered filter for additional safety and to
extend regulator lifen Internal reseating relief valve protects
against overpressurizationn 1 1/29 diameter gaugen Hose barb outletn OPA series designed for pediatric,
homecare, hospital and emergencyapplications
n 2-year limited warranty
OPA-520Compact Click-Style Regulatorwith CGA-540 Nut and Nipple Inlet
OPA Series Regulators Feature Lightweight Aluminum Bodiesand Brass Internal Chambers
OPA-830Compact Click-Style Regulatorwith CGA-870 Yoke Inlet
Western Medica 800-783-7890 13
XB Series Click-Style Brass Regulators
Regulator Features:
n Chrome-plated brass body with all brass high-pressurechamber
n Tested to CGA Standards which include ignition testingn Dial-in flow controln Maximum inlet pressure 3000 psin Sintered filter for additional safety and to extend regulator lifen Internal reseating relief valve protects against
overpressurizationn 1 1/29 diameter gaugen Hose barb outletn 6-year limited warranty
XB-2831Click-Style Regulatorwith CGA-870 Yoke Inlet
Oxygen XB-2831 2 - 15 LPM 20 psi CGA-870 YokeXB-2841 2 - 25 LPM 20 psi CGA-870 YokeXB-2641* 2 - 25 LPM 50 psi CGA-870 Yoke
*Equipped with 2 power take-offs
Standard XB Brass Body Models
Gas Model Flow Range Delivery Pressure Inlet Connection
XB Series Regulators FeatureChrome-Plated Brass Bodiesand Brass High-Pressure Chambers
Western Medica 800-783-789014
Oxygen XA-2701 1/4 - 2 LPM CGA-540 Nut and NippleXA-2711 1/2 - 6 LPM CGA-540 Nut and NippleXA-2721 1 - 8 LPM CGA-540 Nut and Nipple
XA-2800* 1/4 - 2 LPM CGA-870 YokeXA-2801 1/4 - 2 LPM CGA-870 Yoke
XA-2810* 1/2 - 6 LPM CGA-870 YokeXA-2811 1/2 - 6 LPM CGA-870 Yoke
XA-2820* 1 - 8 LPM CGA-870 YokeXA-2821 1 - 8 LPM CGA-870 Yoke
XA-2830* 2 - 15 LPM CGA-870 Yoke
*Regulators without contents gauge
Regulator Features:
n Lightweight aluminum body with brass inlet chambern Tested to CGA Standards which include ignition testingn Dial-in flow controln Maximum inlet pressure 3000 psin Sintered filter for additional safety and to extend regulator lifen Internal reseating relief valve protects against
overpressurizationn 1 1/29 diameter gaugen Hose barb outletn Color-anodized models improve inventory controln 6-year limited warranty
Standard Models – Anodized Aluminum
Gas Model Flow Range Inlet Connection
Oxygen XA-2731 2 - 15 LPM CGA-540 Nut and Nipple SilverXA-2731-G 2 - 15 LPM CGA-540 Nut and Nipple GreenXA-2731-B 2 - 15 LPM CGA-540 Nut and Nipple BlueXA-2731-R 2 - 15 LPM CGA-540 Nut and Nipple Red
XA-2741 2 - 25 LPM CGA-540 Nut and Nipple SilverXA-2741-G 2 - 25 LPM CGA-540 Nut and Nipple GreenXA-2741-B 2 - 25 LPM CGA-540 Nut and Nipple BlueXA-2741-R 2 - 25 LPM CGA-540 Nut and Nipple Red
XA-2831 2 - 15 LPM CGA-870 Yoke SilverXA-2831-G 2 - 15 LPM CGA-870 Yoke GreenXA-2831-B 2 - 15 LPM CGA-870 Yoke BlueXA-2831-R 2 - 15 LPM CGA-870 Yoke Red
XA-2841 2 - 25 LPM CGA-870 Yoke SilverXA-2841-G 2 - 25 LPM CGA-870 Yoke GreenXA-2841-B 2 - 25 LPM CGA-870 Yoke BlueXA-2841-R 2 - 25 LPM CGA-870 Yoke Red
Color – Anodized Aluminum Models
Gas Model Flow Range Inlet Connection ColorXA-2831
XA-2831-G
XA-2831-B
XA-2831-R
XA Series Click-Style Regulators
XA-2701Click-Style Regulatorwith CGA-540 Nut and Nipple Inlet
XA-2821Click-Style Regulatorwith CGA-870 Yoke Inlet
Western Medica 800-783-7890 15
Oxygen XA-2421 1 - 8 LPM 20 psi DISS 1240 CGA-540 Nut and NippleXA-2521 1 - 8 LPM 20 psi DISS 1240 CGA-870 Yoke
XA-2431 2 - 15 LPM 20 psi DISS 1240 CGA-540 Nut and NippleXA-2531 2 - 15 LPM 20 psi DISS 1240 CGA-870 Yoke
XA-2441 2 - 25 LPM 50 psi DISS 1240 CGA-540 Nut and NippleXA-2541 2 - 25 LPM 50 psi DISS 1240 CGA-870 Yoke
XA-2640* 2 - 25 LPM 50 psi 2 Power Take-Offs CGA-870 Yokeand Hose Barb
XA-2641 2 - 25 LPM 50 psi 2 Power Take-Offs CGA-870 Yokeand Hose Barb
*Regulators without contents gauge
Oxygen XA-2311 4 LPM 20 psi Straight Barb CGA-870 Yoke
XA-2321 4 LPM 20 psi 90° Barb CGA-870 Yoke
Note: Preset Flow Regulators are designed for use with fixed demand conserving devices.
XA-2321Preset Flow Regulatorwith CGA-870 Yoke Inlet and90º Barb Outlet
Specialty Click-Style Regulators
Gas Model Flow Range Delivery Pressure Outlet Connection Inlet Connection
Preset Flow Regulators
Gas Model Flow Delivery Pressure Outlet Connection Inlet Connection
XA-2521Click-Style Regulatorwith CGA-870 Yoke Inletand DISS 1240 Outlet
Profile View of XA-2641 Regulator with 2 Power Take-Offs and Hose Barb Outlets
XA-2641Click-Style Regulatorwith CGA-870 Yoke Inletand 2 Power Take-Offs
Western Medica 800-783-789016
n Chrome-plated brass body with all brass high-pressurechamber
n Maximum inlet pressure 3000 psin Maximum static delivery pressure 140 psin Yoke inlet swivels to provide optimum gauge visibilityn Internal reseating relief valve protects against
overpressurizationn 1 1/29 diameter gaugesn Sintered filter for additional safety and to extend
regulator lifen Extended models with DISS 1240 outlet are designed for
use with humidifier bottlen 6-year limited warranty
Oxygen XL-2014* 1/2 - 5 LPM CGA-870 Yoke 90º BarbXL-2004* 1 - 8 LPM CGA-870 Yoke 90º BarbXL-2024* 2 - 15 LPM CGA-870 Yoke 90º Barb
XL-2015 1/2 - 5 LPM CGA-870 Yoke 90º BarbXL-2005 1 - 8 LPM CGA-870 Yoke 90º BarbXL-2025 2 - 15 LPM CGA-870 Yoke 90º Barb
Oxygen XL-2011 1/2 - 5 LPM CGA-540 Nut and Nipple DISS 1240XL-2012 1/2 - 5 LPM CGA-870 Yoke DISS 1240
XL-2001 1 - 8 LPM CGA-540 Nut and Nipple DISS 1240XL-2002 1 - 8 LPM CGA-870 Yoke DISS 1240
XL-2021 2 - 15 LPM CGA-540 Nut and Nipple DISS 1240XL-2022 2 - 15 LPM CGA-870 Yoke DISS 1240
*Regulators without contents gauge
XL-2004*Compact Regulatorwithout Contents Gauge
XL-2011Extended Flow Gauge Regulatorwith CGA-540 Nut and Nipple Inlet
Regulator Features:
Compact Models
Gas Model Flow Range Inlet Connection Outlet Connection
XL Series Compact and Extended Flow Gauge Regulators
Extended Models
XL-2005Compact Flow Gauge Regulatorwith CGA-870 Yoke Inlet
XL-2002Extended Flow Gauge Regulatorwith CGA-870 Yoke Inlet
Western Medica 800-783-7890 17
Oxygen M1-540-PED3 1/32 - 1/2 LPM CGA-540 Nut and NippleM1-540-PED3H 1/32 - 1/2 LPM CGA-540 Handtight Nut and NippleM1-870-PED3 1/32 - 1/2 LPM CGA-870 Yoke
M1-540-PED 1/8 - 1 LPM CGA-540 Nut and NippleM1-540-PEDH 1/8 - 1 LPM CGA-540 Handtight Nut and NippleM1-870-PED 1/8 - 1 LPM CGA-870 Yoke
MR-870-PED Single-Stage Compact Pediatric Regulatorwith CGA-870 Yoke Inlet
n Chrome-plated brass body with all brass high-pressurechamber
n Tested to CGA Standards which include ignition testingn Maximum inlet pressure 3000 psin Maximum static delivery pressure range 158 psi nominaln Internal reseating relief valve protects against
overpressurizationn 29 diameter gauges on M1 Seriesn 1 1/29 diameter gauges on MR Series Compactn Dual scale flow gauge: LPM and CC/Mn Durable neoprene diaphragmn Sintered filter for additional safety and to extend
regulator lifen UL listedn Standard DISS 1240 outlet connection and plastic swivel
hose barbn 6-year limited warranty
M1-540-PED3 Single-Stage Pediatric Regulatorwith CGA-540 Nut and Nipple Inlet
M1 and MR Series Pediatric Regulators
Regulator Features:
Single-Stage Models
Gas Model Flow Range Inlet Connection
Oxygen MR-870-PED3 1/32 - 1/2 LPM CGA-870 YokeMR-870-PED 1/8 - 1 LPM CGA-870 Yoke
Single-Stage Compact Models
Western Medica 800-783-789018
MR-870-8FG Single-Stage Compact Regulatorwith CGA-870 Yoke Inlet
n Chrome-plated brass body with all brass high-pressurechamber
n Tested to CGA Standards which include ignition testingn Maximum inlet pressure 3000 psin Durable neoprene diaphragmn Internal reseating relief valve protects against
overpressurizationn UL listedn 29 diameter gauges on M1 Seriesn 1 1/29 diameter gauges on MR Series Compactn Sintered filter for additional safety and to extend
regulator lifen Standard DISS 1240 outlet connection and plastic swivel
hose barbn 6-year limited warranty
M1-540-15FG Single-Stage Flow Gauge Regulatorwith CGA-540 Nut and Nipple Inlet
Profile View of Single-Stage Regulator
M1 and MR Series Flow Gauge Regulators
Oxygen M1-540-5FG 1/2 - 5 LPM CGA-540 Nut and NippleM1-540-5FGH 1/2 - 5 LPM CGA-540 Handtight Nut and NippleM1-870-5FG 1/2 - 5 LPM CGA-870 Yoke
M1-540-8FG 1 - 8 LPM CGA-540 Nut and NippleM1-540-8FGH 1 - 8 LPM CGA-540 Handtight Nut and NippleM1-870-8FG 1 - 8 LPM CGA-870 Yoke
M1-540-15FG 2 - 15 LPM CGA-540 Nut and NippleM1-540-15FGH 2 - 15 LPM CGA-540 Handtight Nut and NippleM1-870-15FG 2 - 15 LPM CGA-870 Yoke
Single-Stage Compact Models
Oxygen MR-870-5FGX* 1/2 - 5 LPM CGA-870 YokeMR-870-5FG 1/2 - 5 LPM CGA-870 Yoke
MR-870-8FGX* 1 - 8 LPM CGA-870 YokeMR-870-8FG 1 - 8 LPM CGA-870 Yoke
MR-870-15FGX* 2 - 15 LPM CGA-870 YokeMR-870-15FG 2 - 15 LPM CGA-870 Yoke
*Compact regulators without contents gauge
Single-Stage Models
Gas Model Flow Range Inlet Connection
Regulator Features:
Western Medica 800-783-7890 19
n Two-Stage design for applications where flow controlaccuracy is critical such as calibration and testing
n Chrome-plated brass body with all brass high-pressurechamber
n Maximum inlet pressure 3000 psin First stage reduces pressure to 170 psi; second stage
reduces 170 psi to the adjusted liter flown Durable neoprene diaphragmn Internal reseating relief valve protects against
overpressurizationn Sintered filter for additional safety and to extend
regulator lifen UL listedn 29 diameter gaugesn Standard DISS 1240 outlet connection and plastic swivel
hose barbn 6-year limited warranty
M2-540-15FGH Two-Stage Flow Gauge Regulatorwith CGA-540 Handtight Inlet
M2-540-15FG Two-Stage Flow Gauge Regulatorwith CGA-540 Nut and Nipple Inlet
M2 Series Flow Gauge Regulators
Profile View of Two-Stage Regulator
Regulator Features:
Oxygen M2-540-5FG 1/2 - 5 LPM CGA-540 Nut and NippleM2-540-5FGH 1/2 - 5 LPM CGA-540 Handtight Nut and Nipple
M2-540-8FG 1 - 8 LPM CGA-540 Nut and NippleM2-540-8FGH 1 - 8 LPM CGA-540 Handtight Nut and Nipple
M2-540-15FG 2 - 15 LPM CGA-540 Nut and NippleM2-540-15FGH 2 - 15 LPM CGA-540 Handtight Nut and Nipple
Two-Stage Models
Gas Model Flow Range Inlet Connection
Western Medica 800-783-789020
n Chrome-plated brass body with all brass high-pressure chamber
n 15 LPM Oxygen models provide 115 LPM floodn 8 LPM models restricted to 8 LPM maximumn Internal reseating relief valve protects against
overpressurizationn UL listedn 29 diameter gaugen Sintered filter for additional safety and to extend
regulator lifen Durable neoprene diaphragmn Polycarbonate inner and outer tubes provide greater
accuracy and durabilityn Includes plastic swivel hose barb (not shown)n 6-year limited warranty
M1-540-15FM Single-Stage Flowmeter Regulatorwith CGA-540 Nut and Nipple Inlet
M2-540-15FMH
M1 Series Flowmeter Regulator
Oxygen M1-540-8FM 1/2 - 8 LPM CGA-540 Nut and NippleM1-540-8FMH 1/2 - 8 LPM CGA-540 Handtight Nut and NippleM1-870-8FM 1/2 - 8 LPM CGA-870 Yoke
M1-540-15FM 1/2 - 15 LPM CGA-540 Nut NippleM1-540-15FMH 1/2 - 15 LPM CGA-540 Handtight Nut and NippleM1-870-15FM 1/2 - 15 LPM CGA-870 Yoke
Medical Air M1-346-15FM 1 - 15 LPM CGA-346 Nut and NippleM1-346-15FMH 1 - 15 LPM CGA-346 Handtight Nut and NippleM1-950-15FM 1 - 15 LPM CGA-950 Yoke
Carbon Dioxide M1-320-12FM 1/2 - 12 LPM CGA-320 Nut and NippleM1-320-12FMH 1/2 - 12 LPM CGA-320 Handtight Nut and NippleM1-940-12FM 1/2 - 12 LPM CGA-940 Yoke
Single-Stage Models
Gas Model Flow Range Inlet Connection
Regulator Features:
Two-Stage Models are available for applications where flow control accuracy is critical such as calibration and testing.Call Western for more information.
Oxygen MEC-540-8FM 1/2 - 8 LPM CGA-540 Nut and NippleMEC-540-8FMX* 1/2 - 8 LPM CGA-540 Nut and Nipple
MEC-540-15FM 1/2 - 15 LPM CGA-540 Nut and NippleMEC-540-15FMX* 1/2 - 15 LPM CGA-540 Nut and Nipple
MEC-870-8FM 1/2 - 8 LPM CGA-870 YokeMEC-870-8FMX* 1/2 - 8 LPM CGA-870 Yoke
MEC-870-15FM 1/2 - 15 LPM CGA-870 YokeMEC-870-15FMX* 1/2 - 15 LPM CGA-870 Yoke
Medical Air MEC-346-15FM 1 - 15 LPM CGA-346 Nut and NippleMEC-346-15FMX* 1 - 15 LPM CGA-346 Nut and Nipple
MEC-950-15FM 1 - 15 LPM CGA-950 YokeMEC-950-15FMX* 1 - 15 LPM CGA-950 Yoke
Carbon Dioxide MEC-320-12FM 1/2 - 12 LPM CGA-320 Nut and NippleMEC-320-12FMX* 1/2 - 12 LPM CGA-320 Nut and Nipple
MEC-940-12FM 1/2 - 12 LPM CGA-940 YokeMEC-940-12FMX* 1/2 - 12 LPM CGA-940 Yoke
*Regulators without contents gauge
Western Medica 800-783-7890 21
MEC Series Compact Flowmeter Regulator
n Chrome-plated brass body with all brass high-pressurechamber
n Internal reseating relief valve protects againstoverpressurization
n Integrated regulator and flowmeter designn 1 1/29 diameter gaugen Sintered filter for additional safety and to extend
regulator lifen Polycarbonate inner and outer tubes provide greater
accuracy and durabilityn Compact and lightweightn 6-year limited warranty
MEC-870-15FMX*without Contents GaugeCGA-870 Yoke Inlet
MEC-346-15FMCompact Air Flowmeter Regulatorwith CGA-346 Nut and Nipple Inlet
MEC-320-12FMCompact Carbon Dioxide Flowmeter Regulatorwith CGA-320 Nut and Nipple Inlet
MEC-540-15FMCompact Oxygen Flowmeter Regulatorwith CGA-540 Nut and Nipple Inlet
Single-Stage Models
Gas Model Flow Range Inlet Connection
Regulator Features:
Western Medica 800-783-789022 Western Medica 800-783-789022
Oxygen M1-540-PG 0 - 100 psi CGA-540 Nut and NippleM1-540-PGH 0 - 100 psi CGA-540 Handtight Nut and NippleM1-870-PG 0 - 100 psi CGA-870 Yoke
Medical Air M1-346-PG 0 - 100 psi CGA-346 Nut and NippleM1-346-PGH 0 - 100 psi CGA-346 Handtight Nut and NippleM1-950-PG 0 - 100 psi CGA-950 Yoke
Carbon Dioxide M1-320-PG 0 - 100 psi CGA-320 Nut and NippleM1-320-PGH 0 - 100 psi CGA-320 Handtight Nut and NippleM1-940-PG 0 - 100 psi CGA-940 Yoke
Nitrous Oxide M1-326-PG* 0 - 100 psi CGA-326 Nut and NippleM1-326-PGH* 0 - 100 psi CGA-326 Handtight Nut and NippleM1-910-PG* 0 - 100 psi CGA-910 Yoke
Nitrogen M1-580-PG 0 - 100 psi CGA-580 Nut and NippleM1-580-PGH 0 - 100 psi CGA-580 Handtight Nut and NippleM1-960-PG 0 - 100 psi CGA-960 Yoke
Helium M1-580-PG 0 - 100 psi CGA-580 Nut and NippleM1-580-PGH 0 - 100 psi CGA-580 Handtight Nut and NippleM1-930-PG 0 - 100 psi CGA-930 Yoke
Mixed Gases M1-280-PG 0 - 100 psi CGA-280 Nut and NippleM1-500-PG 0 - 100 psi CGA-500 Nut and NippleM1-880-PG 0 - 100 psi CGA-880 YokeM1-890-PG 0 - 100 psi CGA-890 Yoke
*Contents gauge and pressure gauge are color-coded blue
Single-Stage Models
Regulator Features:
M2-346-PG
Two-Stage Models are available for applications where pressure control accuracy is critical such as calibration and testing.Call Western for more information.
n Chrome-plated brass body with all brass high-pressurechamber
n 3000 psi maximum inlet pressuren 2000 SCFH air maximum rated flow at 2000 psin Internal reseating relief valve protects against
overpressurizationn 29 diameter gaugesn Dual scale pressure gauge: psi and kPan UL listedn Durable neoprene diaphragmn Sintered filter for additional safety and to extend
regulator lifen DISS gas specific outletsn 6-year limited warranty
Gas Model Delivery Range Inlet Connection
M1 Series Pressure Gauge Regulator
M1-346-PG Single-Stage Pressure Gauge Regulator with CGA-346 Nut and Nipple Inlet
Western Medica 800-783-7890 23Western Medica 800-783-7890 23
M1 Series Preset Pressure Gauge Regulator
M1-346-P Single-Stage Preset Pressure Gauge Regulatorwith CGA-346 Nut and Nipple Inlet
Regulator Features:
n Chrome-plated brass body with all brass high-pressurechamber
n 3000 psi maximum inlet pressuren 1100 SCFH air maximum rated flow at 2000 psin Internal reseating relief valve protects against
overpressurizationn 29 diameter gauge on M1 Seriesn 1 1/29 diameter gauge on MR Compactn UL listedn Sintered filter for additional safety and to extend
regulator lifen Durable neoprene diaphragmn DISS gas specific outletsn 6-year limited warranty
M2-540-PH
Two-Stage Models are available for applications where flow control accuracy is critical such as calibration and testing.Call Western for more information.
Oxygen M1-540-P 50 psi CGA-540 Nut and NippleM1-540-PH 50 psi CGA-540 Handtight Nut and NippleM1-870-P 50 psi CGA-870 Yoke
MR-870-P 50 psi CGA-870 Yoke (Compact Model)
Medical Air M1-346-P 50 psi CGA-346 Nut and NippleM1-346-PH 50 psi CGA-346 Handtight Nut and NippleM1-950-P 50 psi CGA-950 Yoke
Carbon Dioxide M1-320-P 50 psi CGA-320 Nut and NippleM1-320-PH 50 psi CGA-320 Handtight Nut and NippleM1-940-P 50 psi CGA-940 Yoke
Nitrous Oxide M1-326-P* 50 psi CGA-326 Nut and NippleM1-326-PH* 50 psi CGA-326 Handtight Nut and NippleM1-910-P* 50 psi CGA-910 Yoke
*1000 psi contents gauge color-coded blue
Gas Model Delivery Pressure Inlet Connection
Single-Stage Models
MR-870-P Single-Stage Compact Preset Pressure Gauge Regulatorwith CGA-870 Yoke Inlet
Western Medica 800-783-789024
n Chrome-plated brass body with all brass high-pressurechamber
n Blood gas applications – adjusts to accurate bubble rate with needle valve
n 29 diameter gaugesn Dual scale pressure gauge: psi and kPan Hose barb fitting for 1/89 ID hose includedn Sintered filter for additional safety and to extend
regulator lifen 6-year limited warranty
M1-500-PGB Single-StageClinical Instrumentation Regulatorwith CGA-500 Nut and Nipple Inlet
Ordering Example:Order by replacing X’s in model number with desired CGAnumber from the Gas/Inlet Connections chart. Example:M1-XXX-PGB converts to M1-940-PGB for a Carbon Dioxideregulator with a CGA-940 yoke inlet connection.
M2-500-PGB
M1 Series Clinical Instrumentation Regulator
M1-XXX-PGB 0 - 50 psi Nut and Nipple (NN)M1-XXX-PGBH 0 - 50 psi Handtight Nut and Nipple (HT)M1-XXX-PGB 0 - 50 psi Yoke
Single-Stage Models
Regulator Features:
Model/Gas Delivery Range Inlet Connection
280 880 Carbon Dioxide and Oxygen mixtures (CO2 not over 7.0%)280 890 Helium and Oxygen mixtures (He not over 80.5%)280 890 Nitrogen and Oxygen mixtures (O2 over 23.5%)280 965 Nitrous Oxide and Oxygen mixtures (N2O 47.5 to 52.5%)280 890 Xenon and Oxygen (O2 over 20%)
320 940 Carbon Dioxide326 910 Nitrous Oxide
346 950 Medical Air
500 940 Carbon Dioxide and Oxygen mixtures (CO2 over 7.0%)500 930 Helium and Oxygen mixtures (He over 80.5%)500 973 Carbon Dioxide, Oxygen and Nitrogen500 973 Lung Diffusion Mixtures500 973 Nonflammable, Noncorrosive Diagnostic and Medically
Related Gas Mixtures
540 870 Oxygen580 960 Nitrogen580 930 Helium
Gas/Inlet ConnectionsNN or HT Yoke
CGA CGA(XXX) (XXX) Gas Assignment
Two-Stage Models are available for applications where pressure control accuracy is critical such as calibration and testing.Call Western for more information.
Gas/Inlet ConnectionsNN or HT Yoke
CGA CGA(XXX) (XXX) Gas Assignment
Western Medica 800-783-7890 25
MSH Series High Purity Regulator
MSH15XXX 0 - 15 psi 500 SCFH Nut and Nipple or YokeMSH45XXX 0 - 45 psi 650 SCFH Nut and Nipple or YokeMSH80XXX 0 - 80 psi 950 SCFH Nut and Nipple or YokeMSH180XXX 0 - 180 psi 1000 SCFH Nut and Nipple or YokeMSH450XXX 0 - 450 psi 1000 SCFH Nut and Nipple or Yoke
MSG15XXX 0 - 15 psi 700 SCFH Nut and Nipple or YokeMSG45XXX 0 - 45 psi 1350 SCFH Nut and Nipple or YokeMSG80XXX 0 - 80 psi 2050 SCFH Nut and Nipple or YokeMSG180XXX 0 - 180 psi 2750 SCFH Nut and Nipple or YokeMSG450XXX 0 - 450 psi 2750 SCFH Nut and Nipple or Yoke
Ordering Example:Order by replacing X’s in model number with desired CGAnumber from the Gas/Inlet Connections Chart. Example:MSH45XXX converts to MSH45320 for a Carbon Dioxideregulator with a CGA-320 nut and nipple inlet connection.
n Chrome-plated brass body with all brass high-pressurechamber
n External reseating relief valve protects againstoverpressurization
n 29 diameter gaugesn Teflon® coated Viton® diaphragm minimizes inboard
diffusion of atmospheric contaminantsn Sintered filter for additional safety and to extend
regulator lifen Kel-F® seatn 1/49 NPT outletn 6-year limited warranty
MSH180346 Single-StageHigh Purity Medical Air Regulatorwith CGA-346 Nut and Nipple Inlet
Regulator Features:
Single-Stage Models
Max Rated Flow*Model/Gas Delivery SCFH Air at Inlet
Range 2000 PSI Selection
280 880 Carbon Dioxide and Oxygen mixtures (CO2 not over 7.0%)280 890 Helium and Oxygen mixtures (He not over 80.5%)280 890 Nitrogen and Oxygen mixtures (O2 over 23.5%)280 965 Nitrous Oxide and Oxygen mixtures (N2O 47.5 to 52.5%)280 890 Xenon and Oxygen (O2 over 20%)
320 940 Carbon Dioxide326 910 Nitrous Oxide
346 950 Medical Air
500 940 Carbon Dioxide and Oxygen mixtures (CO2 over 7.0%)500 930 Helium and Oxygen mixtures (He over 80.5%)500 973 Carbon Dioxide, Oxygen and Nitrogen500 973 Lung Diffusion Mixtures500 973 Nonflammable, Noncorrosive Diagnostic and Medically
Related Gas Mixtures
540 870 Oxygen580 960 Nitrogen580 930 Helium
*Maximum rated flow per CGA E-4 1998 at the stated inlet pressure
Western Medica 800-783-789026
FM707S with Power Take-Off, Ohmeda Adapter and Security Chain
FM104Standard Modelw/Chrome-Plated Brass Body
FME104Slim Line Modelw/Chrome-Plated Brass Body
FMA104Slim Line Modelw/Anodized Aluminum Body
FM1001Neonatal Model0.1 – 1 LPMw/Acrylic Outer Tube
FM1101Neonatal Model25 – 200 CC/MINw/Acrylic Outer Tube
Flowmeters – Adult, Pediatric, Neonatal
Flowmeter Features:
n Oxygen, Medical Air and Carbon Dioxide Flowmetersavailable in both Standard and Slim Line models
n Full line of inlet connections availablen Optional power take-off units provide 50 psi additional
outlet pressuren Double units for multi-patient use from one wall outletn Polycarbonate inner and outer tubes provide greater
accuracy and durability on Standard and Slim Line modelsn Neonatal models feature glass inner tube and acrylic
outer tuben 6-year limited warranty