Upload
hansdietrih
View
239
Download
0
Embed Size (px)
Citation preview
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
1/47
B62-2252-00 (E, E2, E3)09 08 07 06 05 04 03 02 01 00
NX-200/ NX-300
NX-200S/ NX-300S
VHF DIGITAL TRANSCEIVER/UHF DIGITAL TRANSCEIVER
INSTRUCTION MANUAL
METTEUR-RCEPTEUR NUMRIQUE VHF/
METTEUR-RCEPTEUR NUMRIQUE UHFMODE DEMPLOI
TRANSCEPTOR DIGITAL VHF/TRANSCEPTOR DIGITAL UHF
MANUAL DE INSTRUCCIONES
RICETRASMETTITORE DIGITALE VHF/
RICETRASMETTITORE DIGITALE UHFMANUALE DI ISTRUZIONI
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
2/47
VHF DIGITAL TRANSCEIVER/UHF DIGITAL TRANSCEIVER
NX-200/ NX-300
NX-200S/ NX-300SINSTRUCTION MANUAL
ENG
LISH
NOTIFICATIONThis equipment complies with the essential requirements of
Directive 1999/5/EC.The use of the warning symbol means the equipment issubject to restrictions of use in certain countries.This equipment requires a licence and is intended for use inthe countries as below.
AT BE DK FI FR DE GR IS
IE IT LI LU NL NO PT ES
SE CH GB CY CZ EE HU LV
LT MT PL SK SI BG ROISO3166
Firmware Copyrights reserved for Kenwood Corporation.
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
3/47
Information on Disposal of Old Electrical and Electronic Equipment and Batteries(applicable for EU countries that have adopted separate waste collection systems)
Products and batteries with the symbol (crossed-out wheeled bin) cannot bedisposed as household waste.Old electrical and electronic equipment and batteries should be recycled at afacility capable of handling these items and their waste byproducts.
Contact your local authority for details in locating a recycle facility nearestto you.Proper recycling and waste disposal will help conserve resources whilstpreventing detrimental effects on our health and the environment.
Notice: The sign "Pb" below the symbol for batteries indicates that this battery
contains lead.
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
4/47
i
THANK YOU
We are grateful you have chosen Kenwoodfor your landmobile radio applications.
This instruction manual covers only the basic operations of your
NEXEDGE portable radio. Ask your dealer for information on anycustomized features they may have added to your radio.
NXDN
NXDN is a protocol name for a new digital communicationssystem using 4-level FSK technology which has beenco-developed by Kenwoodand Icom.
NOTICES TO THE USER Government law prohibits the operation of unlicensed radio
transmitters within the territories under government control.
Safety: It is important that the operator is aware of and
understands hazards common to the operation of anytransceiver.
The AMBE+2TMvoice coding Technology embodied in this productis protected by intellectual property rights including patent rights,copyrights and trade secrets of Digital Voice Systems, Inc. Thisvoice coding Technology is licensed solely for use within this
Communications Equipment. The user of this Technology isexplicitly prohibited from attempting to extract, remove, decompile,reverse engineer, or disassemble the Object Code, or in any otherway convert the Object Code into a human-readable form. U.S.Patent Nos. #5,870,405, #5,826,222, #5,754,974, #5,701,390,#5,715,365, #5,649,050, #5,630,011, #5,581,656, #5,517,511,#5,491,772, #5,247,579, #5,226,084 and #5,195,166.
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
5/47
ii
PRECAUTIONS Do not charge the transceiver and battery pack when they are wet.
Ensure that there are no metallic items located between thetransceiver and the battery pack.
Kenwood. If the die-cast chassis or other transceiver part is damaged, do not
touch the damaged parts.
If a headset or headphone is connected to the transceiver, reducethe transceiver volume. Pay attention to the volume level whenturning the squelch off.
Do not place the microphone cable around your neck while near
machinery that may catch the cable. Do not place the transceiver on unstable surfaces.
Ensure that the end of the antenna does not touch your eyes.
When the transceiver is used for transmission for many hours, theradiator and chassis will become hot. Do not touch these locationswhen replacing the battery pack.
Always switch the transceiver power off before installing optional
accessories. The charger is the device that disconnects the unit from the AC
mains line. The AC plug should be readily accessible.
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
6/47
iii
Turn the transceiver power off in the following locations:
Near explosives or blasting sites.
In aircrafts. (Any use of the transceiver must follow theinstructions and regulations provided by the airline crew.)
Where restrictions or warnings are posted regarding the use ofradio devices, including but not limited to medical facilities.
Near persons wearing pacemakers.
Turn the transceiver power off in the following locations,unless the model is specifically qualified for such use(Intrinsically Safe such as approved by Factory Mutual, CSA):
metallic powders, grain powders, etc.).
While taking on fuel or while parked at gasoline service stations.
Do not remove the black sheet from the reverse side of the
transceiver (refer to the illustration below). Removal of this may cause malfunctions if water seeps into the transceiver.
The orange seal on the reverse side of the transceiver is transceiver. Do not place stickers or other materials on or of the transceiver and may cause it to break down. Additionally,in order to prevent damage to the seal, do not allow it to comein contact with foreign materials.
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
7/47
iv
Do not disassemble or modify the transceiver for any reason.
Do not place the transceiver on or near airbag equipment while may be ejected and strike the driver or passengers.
Do not transmit while touching the antenna terminal or ifany metallic parts are exposed from the antenna covering.Transmitting at such a time may result in a high-frequency burn.
If an abnormal odor or smoke is detected coming from thetransceiver, switch the transceiver power off immediately,remove the battery pack from the transceiver, and contact yourKenwooddealer.
Use of the transceiver while you are driving may be against in your area.
Do not expose the transceiver to extremely hot or coldconditions.
Do not carry the battery pack (or battery case) with metalobjects, as they may short the battery terminals.
Danger of explosion if the battery is incorrectly replaced;replace only with the same type.
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
8/47
v
NOTIFICATION OF WATER-RESISTANT MODEL
Water Resistance and Maintenance (NX-200/ NX-300 Only)
This transceiver conforms to the following standards:
IP67:
dust-resistant level and the second numeral indicates the water-resistant level.
PRECAUTIONS
The applicable standards listed above do not assure that thetransceiver can be used in water. The transceiver may bedamaged in a situation in which the maximum depth is over
1 meter or the maximum submersion time exceeds 30 minutes. Observe the following precautions to maintain the transceivers
water-resistant performance:
a) Do not drop or apply strong physical shocks to the transceiver.
b) When you disassemble the transceiver or open the coverof the option board, IP67 will no longer be maintained. Afterdisassembling the transceiver or opening the cover of theoption board, if you want to continue maintaining IP67, contact
your dealer or Authorized Service Center.c) Do not soak the transceiver in water that contains a solvent or
surfactant, such as detergent or alcohol.
If it is soaked in muddy water or salt water (including sea water), then wipe dry with a soft cloth.
If water is splashed onto the microphone, the battery, or theantenna terminal, clean and dry them with a soft cloth beforereconnecting to the transceiver.
When water gets into the microphone opening or the speakergrill, the voice level may become low or distorted. Lightly shake microphone before operating the transceiver.
Kenwood,may reduce or void the water resistant and dust resistantperformance.
When using an option with the transceiver, ensure that itcorresponds with the IP67 standard.
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
9/47
vi
INFORMATION CONCERNING THE LI-ION BATTERY PACK extreme heat, deteriorate, or cause other forms of damage to thebattery. Please observe the following prohibitive matters.
Do not disassemble or reconstruct battery!
The battery pack has a safety function and protection circuit toavoid danger. If they suffer serious damage, the battery may
Do not short-circuit the battery!
Do not join the + and terminals using any form of metal (suchas a paper clip or wire). Do not carry or store the battery packin containers holding metal objects (such as wires, chain-necklace or hairpins). If the battery pack is short-circuited, objects to heat up.
Do not incinerate or apply heat to the battery!
If the insulator is melted, the gas release vent or safety functionis damaged, or the electrolyte is ignited, the battery may
Do not use or leave the battery near fires, stoves, or otherheat generators (areas reaching over 80C/ 176F)!
If the polymer separator is melted due to high temperature,an internal short-circuit may occur in the individual cells andthe battery may generate heat or smoke, rupture, or burst into
Avoid immersing the battery in water or getting it wet byother means!
If the battery becomes wet, wipe it off with a dry towel beforeuse. If the batterys protection circuit is damaged, the batterymay charge at extreme current (or voltage) and an abnormalchemical reaction may occur. The battery may generate heat or
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
10/47
vii
Do not charge the battery near fires or under directsunlight!
If the batterys protection circuit is damaged, the battery maycharge at extreme current (or voltage) and an abnormalchemical reaction may occur. The battery may generate heat or
Use only the specified charger and observe chargingrequirements!
temperature over the regulated value, excessive high voltageor current over regulated value, or with a remodelled charger),it may overcharge or an abnormal chemical reaction may occur.The battery may generate heat or smoke, rupture, or burst into
Do not pierce the battery with any object, strike it with aninstrument, or step on it!
This may break or deform the battery, causing a short-circuit.The battery may generate heat or smoke, rupture, or burst into
Do not jar or throw the battery!
An impact may cause the battery to leak, generate heat protection circuit is damaged, the battery may charge at anabnormal current (or voltage), and an abnormal chemicalreaction may occur.
Do not use the battery pack if it is damaged in any way!
The battery may generate heat or smoke, rupture, or burst into
Do not solder directly onto the battery!
If the insulator is melted or the gas release vent or safetyfunction is damaged, the battery may generate heat or smoke,
Do not reverse the battery polarity (and terminals)!
When charging a reversed battery, an abnormal chemicalreaction may occur. In some cases, an unexpected large
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
11/47
viii
Do not charge the battery for longer than the specifiedtime!
regulated time has passed, stop it. The battery may generate
Do not place the battery pack into a microwave or highpressure container!
The battery may generate heat or smoke, rupture, or burst into
Keep ruptured and leaking battery packs away from fire!
If the battery pack is leaking (or the battery emits a bad odor),
Do not use an abnormal battery!
If the battery pack emits a bad odor, appears to have differentcoloring, is deformed, or seems abnormal for any other reason,remove it from the charger or operating equipment and do not
use it. The battery may generate heat or smoke, rupture, or
Do not reverse-charge or reverse-connect the battery!
The battery pack has positive and negative poles. If the batterypack does not smoothly connect with a charger or operatingequipment, do not force it; check the polarity of the battery. Ifthe battery pack is reverse-connected to the charger, it will bereverse-charged and an abnormal chemical reaction may occur.The battery may generate heat or smoke, rupture, or burst into
Do not touch a ruptured and leaking battery!
If the electrolyte liquid from the battery gets into your eyes,wash your eyes out with fresh water as soon as possible,
without rubbing your eyes. Go to the hospital immediately. Ifleft untreated, it may cause eye-problems.
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
12/471
UNPACKING AND CHECKING EQUIPMENT ......................... 1
PREPARATION ......................................................... 2
GETTING ACQUAINTED ............................................... 4
PROGRAMMABLE FUNCTIONS....................................... 8
BASIC OPERATIONS ..................................................12
MENU MODE (NX-200/ NX-300 ONLY) .............................15
SCAN....................................................................18
FleetSync: ALPHANUMERIC 2-WAY PAGING FUNCTION .......20
5-TONE SIGNALING (NX-200/ NX-300 ONLY) .....................23
ADVANCED OPERATIONS ............................................25
BACKGROUND OPERATIONS ........................................30
VGS-1 OPTIONAL VOICE GUIDE & STORAGE UNIT ..............33
UNPACKING AND CHECKING EQUIPMENT
Carefully unpack the transceiver. If any items are missing or
Note: These unpacking instructions are for use by your Kenwooddealer, an authorized Kenwoodservice facility, or the factory.
SUPPLIED ACCESSORIESBelt clip........................................................................................1
...............................................2
Universal connector cap..............................................................1
.............................................1
.............................................................. 1
Instruction manual............................................................................. 2
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
13/472
PREPARATION
INSTALLING/ REMOVING THE (OPTIONAL) BATTERY PACK
Note:
For battery pack charging procedures and useage, refer to thebattery charger Instruction Manual.
Before charging a battery pack that is attached to the
While operating the transceiver using a Li-ion battery pack in operating time may be shortened.
INSTALLING THE (OPTIONAL) ANTENNA
connector on the top of thetransceiver by holding theantenna at its base and turning
1
2
3
Optionalantenna
1 Match the guides of the
on the upper rear of the the battery pack in place.
2 Lock the safety catch toprevent accidentally releasingthe battery pack.
3 To remove the battery pack,lift the safety catch, press therelease latch, then pull the transceiver.
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
14/47
glues, may crack the transceivers back panel.
INSTALLING THE CAP OVER THE UNIVERSAL CONNECTOR
INSTALLING THE BELT CLIP
Attach the belt clip using the
Note: If the belt clip is not
installed, its mounting locationmay get hot during continuous a hot environment.
Insert the cap into place over theuniversal connector and secureit in place using the attached
INSTALLING THE (OPTIONAL) SPEAKER/ MICROPHONE ORHEADSET
1 Insert the guide of the headset connector into placeover the universal connector.
2 Secure the connector in place
Note: When not using an optional install the cap over the universalconnector.
3 x 8 mm screw
Belt clip
Universalconnector cap
MIC
1
2ABC
5JKL
0
8TUV
4
7
GHI
PQRS
3DEF
6MNO
MIC
#
9WXYZ
Optional
speaker/ microphone
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
15/47
GETTING ACQUAINTED
NX-200S/ NX-300S
Selector knob
Power switch/Volume control volume.
Auxiliary key
Transmit/ Receive/Battery low indicator
PTT (Push-To-Talk) switch to call a station.
Side 1 key default is Squelch Off Momentary.
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
16/475
Selector knob
Power switch/Volume control
volume. Auxiliary key
Transmit/ Receive/Battery low indicator
1
2ABC
5JKL
0
8TUV
4
7
GHI
PQRS
3DEF
6MNO
MIC
#
9 WXYZ
Side 2 key
Universal connector
NX-200/ NX-300
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
17/476
PTT (Push-To-Talk) switch to call a station.
Side 1 key
The default is Squelch Off Momentary.
Side 2 key The default is Backlight.
Keypad (keypad models only)Press these keys to send DTMF tones. These keys can
a programmable function key is programmed as Function.
key The default is Menu.
key
The default is Zone Up. key
key
key
key
Universal connector
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
18/477
DISPLAY
Indicator Description
Monitor or Squelch Off is activated.
Signaling.
added to scan.
message has arrived.
The current channel is a Priority channel.
Talk Around is activated.
Site Lock is activated.
activated.
Lone Worker is activated.
VOX is activated.
Displays the time.
Displays the key functions for , , and .
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
19/47
PROGRAMMABLE FUNCTIONS
have been programmed on your transceiver.
PROGRAMMABLE FUNCTIONS FOR NX-200S/ NX-300S
Auto Telephone 2
AUX
Battery Indicator
Broadcast
Call 1 ~ 6
CW Message 5
6
Forced Search
Function
Key Lock
Lone Worker
Monitor 7
Monitor Momentary 7
Scan
Site Lock
Site Select
Site Up
Speaker Attenuation 9
Squelch Off 1
Squelch Off Momentary 1
Talk Around7
Telephone Disconnect 2
Vibrator
VOX
Zone Select
Zone Up
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
20/479
1 Available only for Analog Conventional operation.2 Available only for Analog Trunking operation. Available only for NXDN Trunking operation. Can be programmed only on the Selector knob.5
Available only for NXDN Conventional operation.6
7 Available only for Analog Conventional, Analog Trunking, and NXDN
Conventional operation. Available only for Analog Conventional and NXDN Conventional
operation.9 Can be programmed only on the microphone programmable function
keys. 11
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
21/47
Key Lock
Lone Worker
Maintenance Menu
Monitor 9
Monitor Momentary 9
OST 1
Playback 2
Priority-channel Select
12
Scan
Site Lock
Site Select 5
Site Up
5
Speaker Attenuation11
Squelch Level 1
Squelch Off 1
Squelch Off Momentary 1
Stack
Talk Around 9
Vibrator Voice Memo 2
PROGRAMMABLE FUNCTIONS FOR NX-200/ NX-300
Auto Reply Message 2
Autodial
Autodial Programming
AUX Backlight
Broadcast
Call 1 ~ 6
5
Clock
CW Message 6
Digit 1 12
12
Digit 1 Up 12
Up 12
Display Format
7
Forced Search
Function
6
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
22/4711
1 Available only for Analog Conventional operation.2 Available only for Analog Conventional and Analog Trunking
operation. Available only for NXDN Trunking operation.5 Can be programmed only on the Selector knob.6 Available only for NXDN Conventional operation.7
Available only for NXDN Conventional and NXDN Trunking operation.9 Available only for Analog Conventional, Analog Trunking, and NXDN
Conventional operation.Available only for Analog Conventional and NXDN Conventional
operation.
11Can be programmed only on the microphone programmable functionkeys.
12Available only for 5-tone calls.
VOX
Zone Select 5
Zone Up
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
23/4712
BASIC OPERATIONS
SWITCHING POWER ON/OFF
Turn the Power Volume
transceiver ON.Turn the Power Volume
Transceiver Password (NX-200/ NX-300 Only)
1 Select a character using .
2 Press to enter the selected character.
3
Press or #to delete a character. Press and hold or#to delete all characters.
4 Press or
and the transceiver remains locked.
ADJUSTING THE VOLUMERotate the Power Volume decreases it.
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
24/47
SELECTING A ZONE AND CHANNEL/GROUP ID
Select the desired zone using the key programmed as ZoneSelector Zone Up/Down channels.
for transmitting and receiving.
ID names and number by pressing the key programmed as Display
Note: If the default settings for
and the Selector knob have been changed, use the appropriate
TRANSMITTING
1
2 Press the key programmed as Monitoror Squelch Offto
3 Press the PTT Release the PTT
Making Group Calls (Digital) (NX-200/ NX-300 Only)
Group or Group +Status, you can select a group ID from the list to make acall to those parties on a Conventional channel.
To select a group ID:
1 Press the key programmed as Groupor Group + Status.2 Press
3 Press and hold the PTT
transmission.
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
25/47
Making Individual Calls (Digital) (NX-200/ NX-300 Only)
Individual orIndividual + Status persons.
1 Press the key programmed as Individual orIndividual + Status.
2 Press to select a unit ID from the list. On keypad models, you can enter a unit ID directly.
3 Press and hold the PTT
transmission.
RECEIVING
Select the desired zone and channel. If signaling has been if the received signal matches your transceiver settings.
Note: on page 27 for details.
Receiving Group Calls (Digital)
When you receive a group call on a Conventional channeland the received group ID matches the ID set up on yourtransceiver, you can hear the callers voice.
When you receive a group call on a Trunking channel, the channel to receive the call.
Receiving Individual Calls (Digital)
the PTT during a normal transmission.
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
26/4715
MENU MODE (NX-200/ NX-300 ONLY)
through the Menu instead of physical controls. Once you versatility it offers.
MENU ACCESS1 Press the key programmed as Menu.
2 Press to select a category item.
On keypad models, you can enter a category number directly.
3 Press or 4 Press to select a function item.
On keypad models, you can enter a function number directly.
5 Press or to set up the selected function item. Press or #to return to the category list.
6 Press to select your desired setting.
7 Press or Press or #at any time to return to the previous display.
Press
MENU CONFIGURATION
functions listed in the Menu. Those functions can be accesseddirectly by pressing the key. All other functions can still be the available Menu items.
Display Description
AUTO DIAL Autodial Mode
Autodial Programming Mode
AUX
BROADCAST
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
27/4716
Display DescriptionCLOCK
CLOCK ADJUST
DISP FORMAT
Forced Search
INDIVIDUAL Individual mode
Maintenance Display mode
MONITOR
OST
OST LIST OST mode
PLAYBACK Playback mode
Priority Channel Select mode
SCAN
Selcall mode
Display Site Number
Site Select Mode
Squelch Level mode
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
28/4717
Display DescriptionSTACK Stack mode
STATUS Status mode
Short Mesage mode
TALK AROUND
PASSWORD
VIBRATOR
Voice Memo mode
VOX Level mode
VOX
CHARACTER ENTRYThere are 2 methods available for entering characters:
keys
Press
You can also assign a character to an optional key and laterpress that key to recall the assigned character: A ~ Z, a ~ z,
DTMF Key Character Cycle1 1
2 A B C 2
5 J K L 5
6 M N O 6
7 P Q R S 7
9 W X Y Z 9
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
29/47
SCAN
Scan monitors for signals on the transceiver channels. Whilescanning, the transceiver checks for a signal on each channeland only stops if a signal is present.
To begin scanning, press the key programmed as Scan.
The
When a signal is detected on a channel, Scan pauses at that
To stop scanning, press the Scan key again.Note: To use Scan, there must be at least 2 channels in the scansequence.
TEMPORARY CHANNEL LOCKOUT
from the scanning sequence by selecting them and pressingthe key programmed as Scan Delete/Add.
ended and restarted, the channels are reset and deleted channels
PRIORITY SCANNote: To use Priority Scan, a Priority channel must be programmed.
received on that channel, even if a call is being received on anormal channel.
When using dual Priority channels, Priority channel 1 is givenprecedence over Priority channel 2. So, if a call is received on
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
30/4719
SCAN REVERT press the PTT
Selected: The last channel selected before scan.
Selected + Talkback: Same as Selected, plus you can
Priority 1/ Priority 2:
Priority 1 + Talkback/ Priority2 + Talkback: Same as
Last Called + Selected: receive a call.
SCAN DELETE/ADD
and from your scan list.
1
2 Press the key programmed as Zone Delete/Add or Scan Delete/Add
You can also press and hold the key programmed as Scan
Delete/Add
PRIORITY-CHANNEL SELECT (NX-200/ NX-300 ONLY)
If the Priority channel has been set as Operator Selectable byyour dealer, you can reprogram the Priority channels.
1
2 Press the key programmed as Priority-channel Select.
3 Press
4 Press
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
31/47
FleetSync: ALPHANUMERIC 2-WAY PAGING FUNCTION
KenwoodCorporation.
Note: This function is available only in analog operation.
Ask your dealer for further information regarding theNX-200S/ NX-300S.
SELCALL (SELECTIVE CALLING)
A Selcall is a voice call to a station or group of stations.
Transmitting (NX-200/ NX-300 Only)
1 Select your desired zone and channel.
2 Press the key programmed as Selcall or Selcall +Statusto enter Selcall mode.
3 Press
On keypad models, if Manual Dialing is enabled, you can
directly enter the station ID.4 Press the PTT
Receiving
respond to the call by pressing the PTT speaking into the microphone.
Identification Codes
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
32/4721
Select ALL Fleet and ALL ID to make a call to all units
STATUS MESSAGE
be decided in your talk group. Messages can contain up to 16
memory of your transceiver.
Transmitting
1 Select your desired zone and channel.
2 Press the key programmed as Statusto enter Status Selcall + Status to enter
3 Press
If Manual Dialing is enabled, you can enter a station ID
by using the DTMF keypad, or by using . Whenusing , cycle through the digits to select a digit,then press to set the digit and move the cursor to theright. Repeat this process until the entire ID is entered.
4 Press to enter Status mode.
5 Press
If Manual Dialing is enabled, you can enter a status ID by
using the DTMF keypad, or by using
6 Press the PTT Side 2key to initiate the call.
has been successfully transmitted.
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
33/4722
Receiving
is received. Press any key to return to normal operation.
Reviewing Messages in the Stack Memory (NX-200/ NX-300 Only)
1 Press the key programmed as Stack, or press and holdthe key programmed as Selcall,Status, or Selcall +Statusto enter Stack mode. The last received message is displayed.
2 Press to select the desired message.
I: Caller ID, S: Status Message, M: Short Message Press and hold for 1 second or press to cycle the
3 Press to return to normal operation.
To delete the selected message, press or # the deletion, press or .
To delete all messages, press and hold or #for or .
SHORT/LONG MESSAGES
Received short messages are displayed the same as Status
To send short messages, and to send and receive longmessages, you must connect the transceiver to a PC. Askyour dealer for details.
GPS REPORT
pressing the key programmed as Send the GPS data, or by data may be automatically transmitted at a preset time interval.
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
34/47
5-TONE SIGNALING (NX-200/ NX-300 ONLY)
5-tone Signaling is enabled or disabled by your dealer. This the 5 tones programmed in your transceiver. Transceivers that
SELCALL (SELECTIVE CALLING)
A Selcall is a voice call to a station or group of stations.
Transmitting
1 Select your desired zone and channel.
2 Press the key programmed as Selcall, Selcall + Statusor Selcall + SDMto enter Selcall mode.
3 Press
On keypad models, you can directly enter the station ID.
4 Press the key programmed as Call 1to Call 6andbegin your conversation.
Note: Additionally, you can also use the keys programmed as Digit1x Down, Digit 1x Up, Digit 10x Down,and Digit 10x Upkeys to Digit 1x Up/Downthe Selcall number by 1 each time the key is pressed. Digit 10xUp/Down
the key is pressed.
ReceivingWhen you receive a call containing the correct tones, the and the calling stations ID appear on the display. Press anykey to return to normal operation.
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
35/47
STATUS MESSAGE
decided in your talk group. Messages can contain up to 16alphanumeric characters.
stack memory of your transceiver.
Transmitting
1 Select your desired zone and channel.
2 Press the key programmed as Statusto enter Status Selcall + Status to enter
3 Press
You can enter a station ID by using the DTMF keypad, or
by using .
4 Press to enter Status mode.
5 Press
You can enter a status ID by using the DTMF keypad, or byusing
6 Press the key programmed as Call 1to Call 6to initiatethe call.
Receiving
is received. Press any key to return to normal operation.
Reviewing Messages in the Stack Memory
1 Press the key programmed as Stackto enter Stack mode. The last received message is displayed.
2 Press to select the desired message.
Press and hold for 1 second or press to cycle the
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
36/4725
3 Press to return to normal operation.
To delete the selected message, press or # the deletion, press or .
To delete all messages, press and hold or #for
or .
ADVANCED OPERATIONS
DTMF (DUAL TONE MULTI FREQUENCY) CALLS
Making a DTMF Call (NX-200/ MX-300 Only)Manual Dialing (Keypad Models Only)
1 Press and hold the PTT
2
If you release the PTT if the complete number has not been sent.
If the Keypad Auto PTT function has been enabled by your
dealer, you do not need to press the PTT you can make the call simply pressing the DTMF keys.
Store & Send
1 Press the key programmed as Autodial.
2
Alternatively, you can enter digits by using .3 Press the PTT
Autodial (NX-200/ MX-300 Only)
been programmed onto your transceiver.
1 Press the key programmed as Autodial, or access the
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
37/4726
2 Press to select your desired Autodial list
The stored entry appears on the display.
3 Press the PTT
Stun Code
When the transceiver receives a call containing a stuncode, the transceiver becomes disabled. The stun code is
code.
EMERGENCY CALLS
function, you can make emergency calls.
1 Press and hold the key programmed as Emergency.
Ask your dealer for the length of time necessary to hold this
2 Emergency key again.
Note:
Your dealer can set the transceiver to emit tones and received
operation.
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
38/4727
SCRAMBLER
Press the key programmed as Scrambler Encryption, or
Pressing the PTT turned ON encrypts the transmitted signal.
SIGNALING
Quiet Talk (QT)/ Digital Quiet Talk (DQT)
Your dealer may have programmed QT or DQT signaling on
Operator Selectable Tone (OST) (NX-200/ NX-300 Only)
OST, you can
1 Select your desired channel.
2 Press and hold the key programmed as OSTfor1 second.
3 Press to select your desired tone or code.
4 Press
5 OSTkey again to turn the OST function OFF.
Radio Access Number (RAN)
communications.
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
39/47
If a call containing a different RAN is made on the same are using the same channel.
Optional Signaling
Your dealer may also program several types of optionalsignaling for your transceiver channels.
5-tone Signaling (NX-200/ NX-300 Only): Refer to .
DTMF Signaling : DTMF Signaling opens the squelch only DTMF code.
FleetSync Signaling : Refer to
NXDN ID Signaling: NXDN ID is an optional signalingsystem available only for digital communications.
VOICE OPERATED TRANSMISSION (VOX)
VOX can be activated or deactivated by your dealer. VOX
Note:
VOX Gain Level (NX-200/ NX-300 Only)1 Connect the headset to the transceiver.
2 Press the key programmed as VOX.
3 Press level.
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
40/4729
4
5 Press to save the setting.
VOX Operation
1 Connect the headset to the transceiver.
2 Press and hold the key programmed as VOXfor2 seconds.
3 To transmit, simply speak into the microphone. The transceiver recognizes sound levels depending on
speaking.
4
5 To turn the VOX function OFF, press and hold the VOXkey again, for 2 seconds.
Note: level, louder received signals may cause the transceiver to
transmit.
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
41/47
BACKGROUND OPERATIONS
Your dealer can activate a variety of transceiver functions to
CLOCK (NX-200/ NX-300 ONLY)
the key programmed as Clock.
Note: Removing or leaving the battery pack uncharged for
To set the clock:
1 Press the key programmed as Clock Adjustment.
The current time setting appears.
2 Press to increase or decrease the year setting.
3 Press to set the year and cycle to the month setting.
4
5 Press
You can press
VIBRATOR
key programmed as Vibrator to turn the Vibrator function ON and OFF.
TIME-OUT TIMER (TOT)
The Time-out Timer is used to prevent you from using a PTT
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
42/47
BATTERY SAVER
The Battery Saver can be activated only on Conventional
being performed.
KEY LOCK
Press the key programmed as Key Lockto lock and unlock thetransceiver keys.
Squelch Off Momentary, Function, Key Lock, PTT
LOW BATTERY WARNING (NX-200S/ NX-300S)
Press the key programmed as Battery Indicator
Lights Orange Lights Red Blinks Red
LOW BATTERY WARNING (NX-200/ NX-300)
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
43/47
SIGNAL STRENGTH INDICATOR (NX-200/ NX-300 ONLY)
The signal strength indicator displays the strength of received
Strong Weak
COMPANDER
If programmed by your dealer for a channel, the compander
provide higher clarity of signals.
Note:
BUSY CHANNEL LOCKOUT (BCL)
On Conventional channels, if BCL is set up by your dealer, you
If BCL Override has been programmed, you can transmit overthe current signal:
1 Press and hold the PTT
2 Quickly release and then press the PTT
3 call.
CONTROL CHANNEL HUNT
On digital Trunking channels, the transceiver automaticallysearches for a control channel.
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
44/47
PTT ID
time the PTT
Note: PTT ID can be made only in analog operation.
VGS-1 OPTIONAL VOICE GUIDE & STORAGE UNIT
VOICE RECORDER
create voice memos.
Auto Recording (NX-200/ NX-300 Only)
transmitted and received signals. The recording storage
Voice Memos (NX-200/ NX-300 Only)To record a voice memo for later playback:
1 Press the key programmed as Voice Memo, press andhold the key programmed as Playback, or access the
2 Speak into the microphone to record your memo.
3 Press to end the recording and store it in memory.
Auto Reply Message (NX-200/ NX-300 Only)
You can set the transceiver to automatically respond to
1 Press the key programmed as Auto Reply Messagetoenter Auto Reply Message mode.
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
45/47
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
46/47
VOICE GUIDE
Note: Voice announcements vary by dealer setting.
8/10/2019 NX-200 S 300 S Instruction Manual B62-2252-00 English
47/47