27
NuTek ® Devices

Nutek Presentation

Embed Size (px)

DESCRIPTION

 

Citation preview

Page 1: Nutek Presentation

NuTek®  Devices

Page 2: Nutek Presentation

New  EMG\STIM  Devices

Levator  Mini  2  Channel  STIM

Maxi  Plus  1    1  Channel  EMG  

 Levator  Elite      1  Channel  EMG  \  1  Channel  STIM  \  1  Channel  ETS    

 Maxi  Plus  2    1  Channel  EMG  \  2  Channel  STIM  \  1  Channel  ETS    

Page 3: Nutek Presentation

New  EMG\STIM  Devices

Convenient  stand

Colour  dot  matrix  display  and  menu  interface    

Portable  and    user  friendly

Auditory  and  visual  EMG  biofeedback  signal          

Accurate  & sensiDve

OpDonal  mulDlingual  PC  soFware  with  USB    cable  link  to  computer  

Page 4: Nutek Presentation

Clinical    CondiAons

FOR  Clinical  &  Home  Use

SPORTS  

CONTINENCE  

REHABILITATION

PAIN  RELIEF

FITNESS  

Page 5: Nutek Presentation

What  is  EMG?

EMG:  Electromyograph      ü The  measurement  of  electrical  acDvity          that  brings  about  muscle  contracDons.  ü EvaluaDng  and  training  the  muscles.  

Page 6: Nutek Presentation

How  To  Measure  EMG

•  Clean  the  site  of  applicaDon  of  electrode  ;  

•  Place  NuTek  ®  surface  skin  electrodes  ,  vaginal  or  rectal  probe  at  muscle  belly;  

•  NuTek  ®  device  record  muscle  acDvity  at  rest;  

•  NuTek  ®  device  record  muscle  acDvity  upon  voluntary  contracDon  of  the  muscle.  

EMG  Range:  0.2  to  2000  μV  SensiDvity:  0.1  μV    

Page 7: Nutek Presentation

Display  Type  From  NuTek  ®  EMG

threshold threshold

Bar  graph Line  graph

STRONG  MUSCLE  CONTRACTION

WEAK  MUSCLE  CONTRACTION

Page 8: Nutek Presentation

EMG  StaAsAcs  From  NuTek  ®  EMG •  Work  Average:  the  average  value  in  microvolt  of  all  the  Work  

segments  excluding  the  first  second  of  each  segment.  

•   Rest  Average:  as  low  as  you  can  manage,  below  6µV  is  acceptable  while  below  4µV  is  ideal.  

•  Onset  Time:  most  muscles  contract  within  1  second.  

•  Relax  Time:  readings  below  1  second  are  considered  normal  for  most  muscles.    

•  Peak  Value:  working  at  peak  value  during  the  whole  cycle  of  all  the  trials  .  

•  Muscle  DeviaAon:  the  stability  of  the  muscle.  

Page 9: Nutek Presentation

5/5/5  EMG  Assessment

•  5/5/5  =  5  sec  Work  /5  sec  Rest/  5  Trials  

•  Target:  assess  muscle  condiDon  and  quanDfy  the  need  for                                      further  treatment    

Page 10: Nutek Presentation

Fast  ContracAon/Relax  

5  fast  contracDons  (  10  sec  Rest  at  least  before  contracDon)      Target:  Evaluate  or  Training  fast  twitch  fibre  funcDon  

Page 11: Nutek Presentation

10/10/5  Muscle  Endurance

•  10/10/5  =  10  sec  Work  /10  sec  Rest/  5  Trials  

•  Target:  Evaluate  or  Training  slow  twitch  fibre  funcDon                                      

Page 12: Nutek Presentation

STIM:  Electrical  SAmulaAon  

Parameters  Range Programme  Dme 1-­‐  99mins Phase  type W/R,  CON Phase  Dme(m) 1-­‐  99min Frequency  (Hz) 2-­‐100  Hz Pulse  Width(μS) 50-­‐  450  μS Ramp  down  /up  Dme  (s) 0.1-­‐  9.9sec Work/Rest  Dme  (s) 1-­‐  99  sec

Waveform:  Symmetrical  SDmulaDon  cycle:  required  to  prevent  faDgue  

Page 13: Nutek Presentation

STIM:  Effects

•  Produce  substanDal  muscular  tension.    •     Capable  of  increasing  strength.  

ü Used  when  limb  is  immobilized.  ü Also  slows  the  onset  of  atrophy.  

   

Page 14: Nutek Presentation

STIM:  Clinical  CondiAons Clinical  mode   Frequency  

 [Hz]  Pulse  Width  

 [µS]  Amplitude  

[mA]  ConAnence   3-­‐35   200-­‐300    

 0-­‐90  

Sports   4-­‐100   220-­‐350  RehabilitaAon   3-­‐35   80-­‐350  Fitness   4-­‐60   175-­‐320  Pain  relief   2-­‐100   100-­‐200  

Frequency:  cycles  per  second  (1Hz=  1  cycle  per  second      50Hz=50  cycles  per  second)

Page 15: Nutek Presentation

What  Is  ETS  ?  

ETS  (EMG  +  STIM)==  Electromyography  Triggered  SDmulaDon        

Ac#vely  par#cipa#ng  in  the  training!

Page 16: Nutek Presentation

ETS  Training Ø       Closed  loop  training  system  

•     PaDent  aiempts  a  movement,    at  the  same  Dme,  and              generates  a  EMG  signal.  •     When  reaching  a  preset  threshold  of  EMG,    it  triggers            the  sDmulaDon  and  helps  the  paDent  complete  the          movement.  •     PaDent  receives  feedback  about  the  movement  and            learns  how  to  produce  a  normal  movement.  

Ø       Goal    •     Helps  the  paDent  gain  strength  and  awareness  of      

                   muscles  affected  by  neurological  injury.  Ø       CondiAons  known  to  respond  to  ETS

•     Stroke.  •     Pelvic  floor  condiDons.  

Page 17: Nutek Presentation

NuTek  ®  So\ware

Connect  the  device  to  the  PC  or  Smartphone  via  the  USB  cable.  This  funcDon  is  an  opDonal  extra  and  the  user  will  need  to  purchase  the  NuTek®  PC  soFware,  the  USB  connecDon  cable  to  the  PC  or  the  Bluetooth  module  .  The  Smartphone    funcDon    is    realized  by    

communicaDng  with  Bluetooth  module.

Page 18: Nutek Presentation

PaAents    Data

•  :    Choose  PaAent Firstly,  Select  PaAent

The  list  of  finished  sessions  of  the  selected  paAent

Page 19: Nutek Presentation

Available  Protocol  Session:  One

1.    Select  Open  Display

2.    Complete  Open  Display  sessions  

Open  Display    it  is  for  EMG  only  and  advised  to  be  used  as  a  diagnosis  

tool.  

3.  View  staAsAc 4.  View  graph

Page 20: Nutek Presentation

Available  Protocol  Session:  Two

Work/Rest  Assessment  And  Training  Those  are  for  EMG  only    

Assessment  is  advised  to  be  used  by  therapist  evaluaDng  muscle  condiDon.  Training  is  advised  to  be  used  for  paDent  daily  exercise  

Page 21: Nutek Presentation

Available  Protocol  Session:  Three

Nu-­‐Tek  Control  It  is  used  for  ETS  or  STIM  controlled  by  the  device.    

 When  the  paDent  observes  their  EMG  reaching  the  threshold,  it  triggers  

sDmulaDon  and  encourage  the  paDent  to  contract  longer  and  reach  higher  threshold  level  faster.

Page 22: Nutek Presentation

Available  Protocol  Session:  Four

Available  Protocol  Session    :    Three

1.    Draw  the  line,  it  can  be  repeated

2.    Save  the  template

3.  Template  training:  

 PaAent  should  follow  the  line  by  his/her  EMG

Page 23: Nutek Presentation

Home  Reports

Using  the  PC  SoFware,    The  recorded  data  can  be  uploaded  to  PC,  create  the  home  report.  On  the  Report,  the  data  of  first  and  last  day  are  display,      the  EMG,  ETS  ,STIM  data  can  be  compared  day  by  day.  This  funcDonality  is  especially  useful  if  the  PaDent  exercises  day  by  day  at  home  and  comes  periodically  to  the  Doctor/Clinician.  

Page 24: Nutek Presentation

NuTek  Control  Reports  

Note  Icons

The  recorded  data  is  generated  by    NuTek  Control,  it  stores  daily  EMG/STIM/ETS  staDsDcs,  the  staDsDcs  are  organized  in  Monthly  and  Daily  Report  in  the  PC  SoFware.  

Page 25: Nutek Presentation

Clinical  Progress  Reports

Clinical  progress  reports  are  composed  of    Work/Rest  assessment  on  PC  and  in  device  .            Using  the  PC  SoFware,  The  Doctor/Clinician  can  select  the  recorded  sessions  for  the  selected  PaDent  and  create  the  Clinical  Progress  Reports.  On  the  Report  the  EMG  data  can  be  compared  day  by  day.  This  funcDonality  is  especially  useful  if  the  PaDent  exercises  day  by  day  at  home  and  comes  periodically  to  the  Doctor/Clinician  for  evaluaDng  paDent  condiDons.  

Page 26: Nutek Presentation

Other    FuncAon:  PrecripAon

Periodically  the  doctor  or  therapist  will  be  able  to  download  newly  developed  programmes  for  Muscle  SDmulaDon,  EMG  Biofeedback  and  EMG-­‐  TRIGGERED  STIMULATION.  This  helps  this  unique  product  to  keep  abreast  of  any  clinical  trials  where  the  conclusion  is  that  a  specific  programme  or  programme  set  may  assist  in  enhancing  the  treatment  .  

Page 27: Nutek Presentation

Other  FuncAon:  Forgocen  Password

If  you  forget  your  password,  you  have  to  answer  your  secret  quesDons  to  retrieve  it