MANIPAL HOSPITAL,VIJAYAWADA
CARE & HANDLING OF MEDICAL EQUIPMENT
TBS India Telematic and Biomedical Services Pvt Ltd
Medical Equipment
Designed to aid in the diagnosis, monitoring or treatment of medical conditions
Medical Equipment handling by Nurses
Syringe pumps (ICU, WARDS, OT)
Infusion pumps (ICU, WARDS, OT)
Monitors (ICU, WARDS, OT)
Bi-pap /C-pap (ICU, WARDS)
Ventilators (ICU)
TBS India Telematic and Biomedical Services Pvt Ltd
Major Physical damages may happen if not taken care…..…
Electrical hazards
Fluid Spillage
Accidental falling down
Restless patient
Carelessness\Improper usage
TBS India Telematic and Biomedical Services Pvt Ltd
Electrical Hazard
May lead to entire\partial damage of equipment, and if not taken care properly can lead to major fire hazard.
SymptomsBurning smellSmokeExplosion sound
How to avoid…Always connect a 3 pin power chord to ensure patient and operator safetyCheck the power chord skin for any peeling off.Check for Strain reliefEnsure chord properly connected to equipmentDo not use a multiple receptacleEnsure that AC plug is proper, if it is loose from wall inform electrical department before connecting the equipment.Try to avoid using an electrical extension box
TBS India Telematic and Biomedical Services Pvt Ltd
Unfortunately If it happens…..
Remove the equipment from the patient
Disconnect from mains
Inform Biomedical and electrical department
TBS India Telematic and Biomedical Services Pvt Ltd
Fluid Spillage
“If water or any fluid spillage went inside the equipment it can cause
short circuit which then leads to damage of the equipment.”
How to Avoid…..
Do not keep any fluid containers over any equipment.
Keep IV sets away from the equipments.
TBS India Telematic and Biomedical Services Pvt Ltd
Infusion Pump
•OPTIMA VS
TBS India Telematic and Biomedical Services Pvt Ltd
CLEANING
Do not rinse or wipe surfaces
Do not place in an AUTOCLAVE nor IMMERSE the device
Use a cloth soaked in DETERGENT-DISINFECTANT, previously diluted with water if required
Take care also with ALCOHOL BASED SPRAYS (20% - 40% alcohol). They lead to tarnishing and small cracks in the plastic casing.
TBS India Telematic and Biomedical Services Pvt Ltd
Storage
should be stored in a dry and cool placeIn case of prolonged storage time, disconnect the battery through the battery door located on the rear panel . This operation should be made by biomedical engineer
OperationWhile in use ensure that No IV sets are connected straight above the unit, as it may cause fluid spilage and damage the machine or cover the unit with water proof material.
Ensure that clamps are properly fixed.Ensure that power cord are connected properly
TBS India Telematic and Biomedical Services Pvt Ltd
Things to check before start using the equipments…….
Examine the unit for overall conditionChassis/Housing
MountScrew and brackets that attach the unit to an IV pole should be secure and functioning. If the device is mounted on a stand or cart, examine the condition of the mount. Also examine the pole, stand, or cart.
AC Plug/Receptacles
Examine the AC power plug for damage
Line Cord
Inspect the cord for signs of damage. If damaged, replace the entire cord .
TBS India Telematic and Biomedical Services Pvt Ltd
Cables
Inspect drop sensors and remote air-inline detector cables for general condition
Fittings/Connectors
Not applicable
Electrodes/Transducers
Check their physical condition
Controls/Switches
Examine all controls and switches for physical condition, secure mounting, and correct motion
TBS India Telematic and Biomedical Services Pvt Ltd
Syringe Pumps
Injectomat agilia
TBS India Telematic and Biomedical Services Pvt Ltd
Ventilators
Hamilton GalileoPhilips V200Datex ohmeda Engstrom care
TBS India Telematic and Biomedical Services Pvt Ltd
Do not…………
Place anything over the unit…
Move or shift while break is on…
Clean with alcoholic solvants….
Disconnect any cables and accessories before shifting……
Do’s…
Always connect to mains power source…
Ensure brake is on while operation….
Always connect proper power chord…
Don’t use multiple multiple receptacles….
Always connect a 3 pin power chord as it ensures the operator
and patient safety……
Ensure proper length of power chords….
TBS India Telematic and Biomedical Services Pvt Ltd
Patient MonitorMajor parts1: SpO2 2: ECG3: NIBP4: IBP5: Temperature6: EtCO2
Do not remove any accessories forcibly…..
Do not wipe the screen with alcoholic solution…….
Ensure accessories are not getting damaged by patients…..
Always keep accessorie properly…….
TBS India Telematic and Biomedical Services Pvt Ltd
Nagaraju . B TBS-India, Manipal Hospital.