35
DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung, MD National Cancer Center, South Korea Department of Nuclear Medicine

Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

DICOM Korea Workshop 2015

Yonsei University, Gangwon, Korea

August 27, 2015

Nuclear Medicine PACS

and DICOM Application

Kim, Tae-Sung, MD National Cancer Center, South Korea

Department of Nuclear Medicine

Page 2: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

A Nuclear Medicine Study

Kim - Nuclear Medicine PACS

Radiopharmaceuticals

Cyclotron - Generator

Tagging

Page 3: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

A Nuclear Medicine Study

Radiopharmaceuticals

Page 4: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

A Nuclear Medicine Study

Kim - Nuclear Medicine PACS

Report:

LVEF (Left Ventricular

Ejection Fraction) is 63%.

Page 5: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

Scanner for Nuclear Medicine

Kim - Nuclear Medicine PACS

Page 6: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

Nuclear Medicine Images

Kim - Nuclear Medicine PACS

Page 7: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

Nuclear Medicine Images

Kim - Nuclear Medicine PACS

Nuclear Medicine Radiology

Function Anatomy

Activity Morphology

Page 8: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

Image flow: before PACS

Page 9: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

Image flow: PACS era

Page 10: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

Primary images vs Screen Capture

Kim - Nuclear Medicine PACS

Primary images of cardiac blood pool Screen Capture of Workstation

+

Only?

1)

2)

Page 11: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

Primary Image vs. Screen Capture

Kim - Nuclear Medicine PACS

Hold information for quantification No information for quantification

+

Only?

1)

2)

Page 12: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

Primary images vs Screen Capture

Kim - Nuclear Medicine PACS

Stack of primary images Screen Capture of MIP

Page 13: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

Old storage for NM images

Kim - Nuclear Medicine PACS

Page 14: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

Interfile

A file format for NM image

1982 COST-B2 project of European community

Need to design quality assurance programs

Define a file format for data sharing

Contains information about study and images

Kim - Nuclear Medicine PACS

Page 15: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

Interfile: file format for NM image

Limitations of `Interfile`

Lacks many information fields such as image position, orientation, …

Only for images from nuclear medicine

A file format specification, not a transfer protocol

Kim - Nuclear Medicine PACS

CeraSPECT

Old scanner’s workstation produce

‘nice’ interfile but

‘awful’ DICOM formatted file.

Old scanner’s workstation

can export/import interfile,

can export DICOM-file,

canNOT import DICOM-file.

Page 16: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

Old scanner’s images

at New workstation

Incompatible DICOM header

DICOM elements to calculate SUV, 3D positioning/orientation

Problems manipulating old PET machines images

(Gemini, Advances, …) at workstations from other vendor

Kim - Nuclear Medicine PACS

Philips Gemini PET image on GE Centricity Viewer

Page 17: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

Quantitation using PET scanner

Kim - Nuclear Medicine PACS

SUV = 26 g/ml

Page 18: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

Quantitation using PET scanner

Kim - Nuclear Medicine PACS

Standardize activity

Page 19: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

Application of SUV

Kim - Nuclear Medicine PACS

SUV=15g/ml

Metastasis from Colon cancer

SUV=3g/ml

Nodular hyperplasia

Page 20: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

Application of SUV

Kim - Nuclear Medicine PACS

Complete Metabolic Response:

MaxSUV 11.6background

Partial Metabolic Response:

Decrease in MaxSUV > 25% (20.99.5)

Treatment response evaluation (Chemotherapy+Radiotherapy)

Before therapy

Before therapy After therapy

After therapy

Page 21: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

Quantifying metabolism

using DICOM formatted PET image

Kim - Nuclear Medicine PACS

Page 22: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

Kim - Nuclear Medicine PACS

22147 Bq/ml

Quantifying metabolism

using DICOM formatted PET image

Injected dose 459589504 Bq

Time 10:20:48 - 9:23:00 = 3420 sec

Half life of F-18 = 6588 sec

Decay corrected injected dose = 320.7MBq

Page 23: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

Quantifying metabolism

using DICOM formatted PET image

Kim - Nuclear Medicine PACS

c(t) = 0.022147 MBq/ml

corrected injected activity(t) = 320.7MBq

body weight = 62 kg = 62000 g

SUV(t) = 4.28 g/ml

Required data elements for calculating SUV

(0054,1001) Units

(0010,1030) Patient’s Weight

(0054,0016)

> (0018,1072) Radiopharmaceutical Start Time

> (0018,1074) Radionuclide Total Dose

> (0018,1075) Radionuclide Half Life

(0008,0031) Series Time

Page 24: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

Problems in Calculating SUVs

Kim - Nuclear Medicine PACS

(0008,0021) DA '20131204' # Series Date

(0008,0031) TM '083220' # Series Time

(0018,1072) TM '120000.00' # Radiopharmaceutical Start Time

(0018,1074) DS '2996089088' # Radionuclide Total Dose

(0018,1075) DS '230400' # Radionuclide Half Life

Y-90 Half-life ~ 2.67 days

(0018,1078) DT '20131203120000.00' # Radiopharmaceutical Start Datetime

Page 25: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

Problems in Calculating SUVs

Kim - Nuclear Medicine PACS

Page 26: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

Problems in Quantification

Kim - Nuclear Medicine PACS

Max 1971

Max 255

Max 255

Max 6026

Page 27: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

Image Compression

Lossy image compression

Kim - Nuclear Medicine PACS

Page 28: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

Image Compression

Lossy image compression vs. Lossless compression

Kim - Nuclear Medicine PACS

I wanted to compare a study with an older study. Just after opening the case, I found that images of old study were spoiled.

Page 29: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

Image Compression

Lossy compression in NM image

- NM images have more noise than X-ray or CT or MR

- Severely degraded even in a low compression ratio

- Quantification using lossy compressed image alter study result.

Kim - Nuclear Medicine PACS

Page 30: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

Image Compression

Kim - Nuclear Medicine PACS

Lossy

Irreversible

Lossless

Reversible

Uncompressed

Page 31: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

Loss of Data elements

Kim - Nuclear Medicine PACS

Private Tags for calculating SUV

(image from Philips® PET scanner)

Private Tags is missing!

SUV cannot be calculated.

A DICOM file in long term storage

A DICOM file of PET image

I fetched an old study from PACS into my PET workstation. However, PET workstation didn’t show SUV number!

Page 32: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

VR with UN (Unknown VR)?

Kim - Nuclear Medicine PACS

(0054,0414) SQ (Sequence with explicit length #=1) # 54, 1 PatientGantryRelationship

(fffe,e000) na (Item with explicit length #=3) # 46, 1 Item

(0008,0100) SH [G-5191] # 6, 1 CodeValue

(0008,0102) SH [99SDM] # 6, 1 CodingSchemeDesignator

(0008,0104) LO [Feet-first] # 10, 1 CodeMeaning

(fffe,e00d) na (ItemDelimitationItem for re-encoding) # 0, 0 ItemDelimitationItem

(fffe,e0dd) na (SequenceDelimitationItem for re-encod.) # 0, 0 SequenceDelimitationItem

(0055,0010) LO [SIEMENS MED NM] # 14, 1 PrivateCreator

(0055,107e) UN 00\00\c8\41 # 4, 1 Unknown Tag & Data

(0055,10c0) UN 2f\00\11\00\d1\03\ef\00 # 8, 1 Unknown Tag & Data

VR is missing somewhere

Private data elements became unreadable

I opened a study of out-hospital patient and I felt something wrong…

Page 33: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

Risk of NM images in PACS

Saving storage by

performing lossy-compression,

removing data elements with private tag,

storing in “Implicit VR Little Endian”

Kim - Nuclear Medicine PACS

Image is displayed well anyway.

But, Information for quantification is gone!

Page 34: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

Please…

Quantification is crucial in Nuclear Medicine.

Do store “primary” nuclear medicine images if possible

Don’t lossy-compress

“Nuclear Medicine Image” and

“Positron Emission Tomography Image”

(“CT Image” and “Secondary Capture” are okay)

Don’t discard “private” data elements

Kim - Nuclear Medicine PACS

Page 35: Nuclear Medicine PACS and DICOM Application...DICOM Korea Workshop 2015 Yonsei University, Gangwon, Korea August 27, 2015 Nuclear Medicine PACS and DICOM Application Kim, Tae-Sung,

Author Contacts

Kim, Tae-Sung • [email protected]

• 111 Jungbalsan-ro, Ilsandong-gu,

Goyang-si, Gyeonggi-do, 10408 Republic of Korea

Kim - Nuclear Medicine PACS

Thank you for your attention!