NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 1 of 45 NOT PROTECTIVELY MARKED Parent Document Ref: BEG/ICP/QUA/DM/003 Template Ref: BEG/FORM/QUA/002 Rev 022 Nuclear Generation Limited Company Specification Generic Emergency Handbook Section 8 Notifications, Warnings and Countermeasures Originated by: L Driver Emergency Planning Group Date: September 2012 Reviewed by: G Woodcock Emergency Planning Group Date: September 2012 Approved by: J Skegg Emergency Planning Group Head Date: September 2012 Revision Amendment Impact level Date 006 Document converted to new EDF NG template Minor September 2012 © 2012 Published in the United Kingdom by EDF Energy Nuclear Generation Ltd. All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, including photocopying and recording, without the written permission of the copyright holder, EDF Energy Nuclear Generation Ltd, application for which should be addressed to the publisher. Such written permission must also be obtained before any part of this publication is stored in a retrieval system of any nature. Requests for copies of this document should be referred to Barnwood Document Centre, Location 12, EDF Energy Nuclear Generation Ltd, Barnett Way, Barnwood, Gloucester GL4 3RS (Tel: 01452-652791). The electronic copy is the current issue and printing renders this document uncontrolled. Controlled copy-holders will continue to receive updates as usual. LIMITATION OF LIABILITY – Whilst EDF Energy Nuclear Generation Ltd believes that the information given in this document is correct at the date of publication it does not guarantee that this is so, nor that the information is suitable for any particular purpose. Users must therefore satisfy themselves as to the suitability of the information for the purpose for which they require it and must make all checks they deem necessary to verify the accuracy thereof. EDF Energy Nuclear Generation Ltd shall not be liable for any loss or damage (except for death or personal injury caused by negligence) arising from any use to which the information is put.

Nuclear Generation Limited - EDF Energy · emergency message over the Public Address system. The announcement, where practical will be made by the Emergency Controller or Shift Manager

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 1 of 45

NOT PROTECTIVELY MARKED Parent Document Ref: BEG/ICP/QUA/DM/003 Template Ref: BEG/FORM/QUA/002 Rev 022

Nuclear Generation Limited

Company Specification

Generic Emergency Handbook Section 8 Notifications, Warnings and Countermeasures Originated by: L Driver

Emergency Planning Group Date: September 2012

Reviewed by: G Woodcock Emergency Planning Group

Date: September 2012

Approved by: J Skegg Emergency Planning Group Head

Date: September 2012

Revision Amendment Impact level Date

006 Document converted to new EDF NG template Minor September 2012

© 2012 Published in the United Kingdom by EDF Energy Nuclear Generation Ltd. All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, including photocopying and recording, without the written permission of the copyright holder, EDF Energy Nuclear Generation Ltd, application for which should be addressed to the publisher. Such written permission must also be obtained before any part of this publication is stored in a retrieval system of any nature. Requests for copies of this document should be referred to Barnwood Document Centre, Location 12, EDF Energy Nuclear Generation Ltd, Barnett Way, Barnwood, Gloucester GL4 3RS (Tel: 01452-652791). The electronic copy is the current issue and printing renders this document uncontrolled. Controlled copy-holders will continue to receive updates as usual. LIMITATION OF LIABILITY – Whilst EDF Energy Nuclear Generation Ltd believes that the information given in this document is correct at the date of publication it does not guarantee that this is so, nor that the information is suitable for any particular purpose. Users must therefore satisfy themselves as to the suitability of the information for the purpose for which they require it and must make all checks they deem necessary to verify the accuracy thereof. EDF Energy Nuclear Generation Ltd shall not be liable for any loss or damage (except for death or personal injury caused by negligence) arising from any use to which the information is put.

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 2 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

Contents

8.1 Public Address Announcements of Standard Emergency Message.................................4

1. Introduction..........................................................................................................................4

2. Off Site Nuclear Emergency and Site Incident Standard Messages.....................................4

3. Use of the Public Address System for Other Messages .......................................................4

4. Location of Site Emergency Warning Signal and Public Address System ............................5

5. Extent of Coverage ..............................................................................................................5

6. Change of Condition ............................................................................................................5

7. Stand-Down.........................................................................................................................5

8.2 Procedure for Assessing the Need for the Issuing of Potassium Iodate Tablets to Persons on Site.............................................................................................................22

1. Introduction........................................................................................................................22

2. Criteria for Taking Iodate Tablets.......................................................................................22

3. Repeat Dosages ................................................................................................................23

4. Instruction Card – Personnel on Site..................................................................................23

5. Site-Stocks of Iodate Tablets .............................................................................................23

6. Buffer Stocks .....................................................................................................................24

7. Casualties..........................................................................................................................24

8.3 Transfer of Emergency Control Centre ..........................................................................25

1. Introduction........................................................................................................................25

2. Prior Arrangement 25

3. Post Movement Arrangements...........................................................................................25

4. Criteria for Evacuation of an Operational ECC 26

5. Location.............................................................................................................................26

8.4 Notification of External Organisations and Station Emergency Personnel .....................27

1. Introduction........................................................................................................................27

2. Standard Messages...........................................................................................................27

3. Actions...............................................................................................................................27

4. ONR Call Back...................................................................................................................28

5. Cancellation.......................................................................................................................28

8.5 Emergency Organisation Staffing Resources ................................................................31

1. Purpose .............................................................................................................................31

2. Scope ................................................................................................................................31

3. Practice..............................................................................................................................31

8.6 Advising the Police on Counter Measures .....................................................................35

1. Introduction........................................................................................................................35

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 3 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

2. Countermeasure Advice ....................................................................................................35

3. Predicted Sources of Exposure..........................................................................................37

4. Radiological Information ....................................................................................................38

5. Prior Information to the Public in the DEPZ........................................................................39

6. Method of Presentation of Recommendation and Advice to the Police...............................39

8.7 Guidance on Declaration Conditions .............................................................................41

1. Introduction........................................................................................................................41

2. Site Incident.......................................................................................................................41

3. Off Site Nuclear Emergency...............................................................................................41

8.8 Off Site Potassium Iodate Tablet Distribution Arrangements .........................................43

1. Introduction........................................................................................................................43

2. Potassium Iodate Stocks....................................................................................................43

3. Collection & Distribution.....................................................................................................43

4. Prior Authority to Issue.......................................................................................................43

Appendix EP/8.4/1 Site Incident Notification Message..........................................................44

Appendix EP/8.4/2 Off Site Nuclear Emergency Notification Message..................................45

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 4 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

8.1 Public Address Announcements of Standard Emergency Message

1. Introduction

Activation of the emergency organisation and informing personnel on site that a Site Incident or Off Site Nuclear Emergency condition exists on site will be done by sounding the Site Emergency Warning Signal for a minimum of 40 seconds and then announcing a standard emergency message over the Public Address system. The announcement, where practical will be made by the Emergency Controller or Shift Manager but the senior person in the Central Control Room may act on their behalf when a prompt alarm and announcement is necessary to limit hazards and casualties.

2. Off Site Nuclear Emergency and Site Incident Standard Messages

2.1 The Public Address Announcement will be composed from the following standard message. “ATTENTION ALL PERSONNEL, ATTENTION ALL PERSONNEL, AN ACCIDENT HAS

OCCURRED ON (insert plant identification)

A SITE INCIDENT (OFF SITE NUCLEAR EMERGENCY)* IS NOW IN FORCE. I REPEAT A SITE INCIDENT (OFF SITE NUCLEAR EMERGENCY)* IS NOW IN FORCE.

PROCEED TO YOUR MUSTER POINT AVOIDING (specify areas of site and roadway as

necessary)* CLOSING DOORS AND WINDOWS If an Off Site Nuclear Emergency has been declared the following should be added: ALL STAFF SHOULD TAKE POTASSIUM IODATE TABLETS. I REPEAT ALL STAFF

SHOULD TAKE POTASSIUM IODATE TABLETS STANDBY FOR FURTHER INSTRUCTIONS.” (* delete as appropriate) Repeat the instruction after 5 minutes to remind persons arriving at Muster Points who did not

hear the original message in noisy areas of the plant.

3. Use of the Public Address System for Other Messages

The PA System is useful because it is the most effective method of informing all people on site.

The PA System can be used for:

- providing updates of the event to Site Personnel;

- requesting individuals to come forward for specialist roles;

- establishing if missing personnel are at muster points.

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 5 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

However the use of the PA System must be subject to some simples rules: (i) Always write down your PA message before saying it.

(ii) Give a warning that there will be a PA Announcement so that people are ready to Listen. This could be a musical chime (Bing Bong) or a simple statement such as “The Emergency Controller will address you in 30 Seconds”.

(iii) Speak clearly and slowly.

(iv) Repeat phone numbers or other important information.

(v) Finish the announcement with “Message Ends”.

(vi) Do not say there will be updates to information in 30 minutes because people will expect it. Better to say “an update will be given when more information becomes available”.

(vii) Keep messages short and to the point.

(viii) Do not overuse the PA System or use it for trivial messages.

4. Location of Site Emergency Warning Signal and Public Address System

4.1 The Site Emergency Warning Signal can be initiated by pressing the button marked (Site Specific) located (Site Specific) and cancelled by (Site Specific)

4.2 Public Address access is located at (Site Specific) and (Site Specific)

Detailed operating instructions are adjacent to the equipment.

[Site Emergency Warning Signals and Public Address systems on adjacent stations should be capable of initiation and operation from either station if practicable].

5. Extent of Coverage

5.1 The Site Emergency Warning Signal coverage extends throughout the site and is supplemented by visual warning in (Site Specific) where high ambient noise levels obscure the alarm.

5.2 The Public Address system covers all Muster Points, emergency centres, control point locations and the site in general but coverage may be poor in areas where temporary high noise levels are present (due to a steam leak for example), which are not covered by visual warning.

6. Change of Condition

Messages announcing changes in declaration status should be preceded by the sounding of the Site Emergency Warning Signal for 40 seconds. The Site Emergency Warning Signal need not be sounded for other less important messages.

7. Stand-Down

When the criteria for Stand-Down of an Incident have been met (see sections 8.4.5 and 15.4) a Public Address announcement preceded by the sounding of the Site Emergency Warning Signal for 40 seconds shall be made giving clear instructions to staff of the Conditions of Stand-Down (e.g. any restricted areas).

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 6 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

When the initial declaration is made and when the emergency status is up-graded, down-graded or terminated, the Site Emergency Warning Signal and Public Address announcements should be broadcast on both stations of twin-station-sites. Selective broadcasting or Public Address announcements can be exercised at other times.

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 7 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

MESSAGE 1 - Standard Site Incident Declaration

[SOUND SIREN BEFORE FIRST READING]

ATTENTION ALL PERSONNEL

ATTENTION ALL PERSONNEL

THIS IS AN EMERGENCY MESSAGE

THIS IS AN EMERGENCY MESSAGE

AN ACCIDENT HAS OCCURRED ON [SPECIFY]

A SITE INCIDENT IS NOW IN FORCE, I REPEAT

A SITE INCIDENT IS NOW IN FORCE

ALL STAFF, I REPEAT

ALL STAFF ARE TO GO TO THEIR INDOOR MUSTER POINT SHUTTING DOORS AND WINDOWS ON ROUTE. AVOID THE FOLLOWING AREAS

[SPECIFY]

STAY AT YOUR MUSTER POINT AND AWAIT FURTHER INSTRUCTIONS. EMERGENCY TEAMS ARE TO DEPLOY TO THEIR EMERGENCY

RESPONSE LOCATIONS IMMEDIATELY FOLLOWING MUSTER AND BEGIN EMERGENCY DUTIES

MESSAGE ENDS

[REPEAT MESSAGE AFTER FIVE MINUTES]

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 8 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

MESSAGE 2 - Standard Off Site Nuclear Emergency Declaration

[SOUND SIREN BEFORE FIRST READING]

ATTENTION ALL PERSONNEL

ATTENTION ALL PERSONNEL

THIS IS AN EMERGENCY MESSAGE

THIS IS AN EMERGENCY MESSAGE

AN ACCIDENT HAS OCCURRED ON [SPECIFY]

AN OFF SITE NUCLEAR EMERGENCY IS NOW IN FORCE, I REPEAT

AN OFF SITE NUCLEAR EMERGENCY IS NOW IN FORCE

ALL STAFF, I REPEAT

ALL STAFF ARE TO GO TO THEIR INDOOR MUSTER POINT SHUTTING DOORS AND WINDOWS ON ROUTE. AVOID THE FOLLOWING AREAS

[SPECIFY]

ALL STAFF SHOULD TAKE POTASSIUM IODATE TABLETS WITH A FULL CUP OF WATER.

STAY AT YOUR MUSTER POINT AND AWAIT FURTHER INSTRUCTIONS.

EMERGENCY TEAMS ARE TO DEPLOY TO THEIR EMERGENCY RESPONSE LOCATIONS IMMEDIATELY FOLLOWING MUSTER AND

BEGIN EMERGENCY DUTIES

MESSAGE ENDS

[REPEAT MESSAGE AFTER FIVE MINUTES]

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 9 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

MESSAGE 3 - Fire Site Incident Declaration

[SOUND SIREN BEFORE FIRST READING]

ATTENTION ALL PERSONNEL

ATTENTION ALL PERSONNEL

THIS IS AN EMERGENCY MESSAGE

THIS IS AN EMERGENCY MESSAGE

AN ACCIDENT HAS OCCURRED ON [SPECIFY]

A SITE INCIDENT IS NOW IN FORCE, I REPEAT

A SITE INCIDENT IS NOW IN FORCE

ALL STAFF, I REPEAT

ALL STAFF ARE TO GO TO THEIR EXTERNAL MUSTER POINT SHUTTING DOORS AND WINDOWS ON ROUTE. AVOID THE

FOLLOWING AREAS [SPECIFY]

EXTERNAL MUSTER POINTS ARE LOCATED AT THE, SOUTH WEST TURNSTILE, OUTSIDE THE MECHANICAL WORKSHOP, OUTSIDE THE WORK EXECUTION CENTRE, OUTSIDE THE OPS MESS ROOM AND AT

THE NORTH CONTRACTORS COMPOUND

STAY AT YOUR MUSTER POINT AND AWAIT FURTHER INSTRUCTIONS. EMERGENCY TEAMS ARE TO DEPLOY TO THEIR EMERGENCY

RESPONSE LOCATIONS IMMEDIATELY FOLLOWING MUSTER AND BEGIN EMERGENCY DUTIES

MESSAGE ENDS

[REPEAT MESSAGE AFTER FIVE MINUTES]

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 10 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

MESSAGE 4 - Security Site Incident Declaration

[SOUND SIREN BEFORE FIRST READING]

ATTENTION ALL PERSONNEL

ATTENTION ALL PERSONNEL

THIS IS AN EMERGENCY MESSAGE

THIS IS AN EMERGENCY MESSAGE

A SECURITY INCIDENT HAS OCCURRED

A SITE INCIDENT IS NOW IN FORCE, I REPEAT

A SITE INCIDENT IS NOW IN FORCE

ALL STAFF, I REPEAT

ALL STAFF ARE TO GO TO THEIR INDOOR MUSTER POINT SHUTTING DOORS AND WINDOWS ON ROUTE. AVOID THE FOLLOWING AREAS

[SPECIFY]

STAY AT YOUR MUSTER POINT AND AWAIT FURTHER INSTRUCTIONS.

EMERGENCY TEAMS ARE TO DEPLOY TO THEIR EMERGENCY

RESPONSE LOCATIONS IMMEDIATELY FOLLOWING MUSTER AND

BEGIN EMERGENCY DUTIES

MESSAGE ENDS

[REPEAT MESSAGE AFTER FIVE MINUTES]

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 11 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

MESSAGE 5 - Chemical Site Incident Declaration

[SOUND SIREN BEFORE FIRST READING]

ATTENTION ALL PERSONNEL

ATTENTION ALL PERSONNEL

THIS IS AN EMERGENCY MESSAGE

THIS IS AN EMERGENCY MESSAGE

A CHEMICAL INCIDENT HAS OCCURRED

A SITE INCIDENT IS NOW IN FORCE, I REPEAT

A SITE INCIDENT IS NOW IN FORCE

ALL STAFF, I REPEAT

ALL STAFF ARE TO GO TO THEIR INDOOR MUSTER POINT SHUTTING DOORS AND WINDOWS ON ROUTE. AVOID THE FOLLOWING AREAS

[SPECIFY]

STAY AT YOUR MUSTER POINT AND AWAIT FURTHER INSTRUCTIONS.

EMERGENCY TEAMS ARE TO DEPLOY TO THEIR EMERGENCY

RESPONSE LOCATIONS IMMEDIATELY FOLLOWING MUSTER AND

BEGIN EMERGENCY DUTIES

MESSAGE ENDS

[REPEAT MESSAGE AFTER FIVE MINUTES]

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 12 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

MESSAGE 6 - Off Site Nuclear Emergency without KI Declaration (adjacent de fuelled sites)

[SOUND SIREN BEFORE FIRST READING]

ATTENTION ALL PERSONNEL

ATTENTION ALL PERSONNEL

THIS IS AN EMERGENCY MESSAGE

THIS IS AN EMERGENCY MESSAGE

AN ACCIDENT HAS OCCURRED ON [SPECIFY]

AN OFF SITE NUCLEAR EMERGENCY IS NOW IN FORCE, I REPEAT

AN OFF SITE NUCLEAR EMERGENCY IS NOW IN FORCE

ALL STAFF, I REPEAT

ALL STAFF ARE TO GO TO THEIR INDOOR MUSTER POINT SHUTTING DOORS AND WINDOWS ON ROUTE. AVOID THE FOLLOWING AREAS

[SPECIFY]

DUE TO THE NATURE OF THE RELEASE, STAFF SHOULD NOT TAKE POTASSIUM IODATE TABLETS, I REPEAT

DUE TO THE NATURE OF THE RELEASE, STAFF SHOULD NOT TAKE

POTASSIUM IODATE TABLETS.

STAY AT YOUR MUSTER POINT AND AWAIT FURTHER INSTRUCTIONS.

EMERGENCY TEAMS ARE TO DEPLOY TO THEIR EMERGENCY

RESPONSE LOCATIONS IMMEDIATELY FOLLOWING MUSTER AND

BEGIN EMERGENCY DUTIES

MESSAGE ENDS

[REPEAT MESSAGE AFTER FIVE MINUTES]

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 13 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

MESSAGE 7 - ECC Take Control Of Incident Message

[USE PRE-MESSAGE IN MESSAGE 10 PRIOR TO THIS]

ATTENTION ALL PERSONNEL

ATTENTION ALL PERSONNEL

THIS IS AN EMERGENCY MESSAGE

THIS IS AN EMERGENCY MESSAGE

THIS IS [SPECIFY] THE EMERGENCY CONTROLLER SPEAKING

A [ SITE INCIDENT / NUCLEAR EMERGENCY ] HAS BEEN DECLARED IN RESPONSE TO AN INCIDENT THAT HAS OCCURRED ON [SPECIFY]

THE ECC HAS BEEN ESTABLISHED AND I HAVE NOW TAKEN OVER

CONTROL OF THE INCIDENT FROM THE SHIFT MANAGER. OUR

EMERGENCY TEAMS ARE DEPLOYED TO ASSESS THE SITUATION.

ALL STAFF SHOULD REMAIN AT THEIR MUSTER POINTS AND FOLLOW

THE INSTRUCTIONS OF THE SENIOR PERSONS PRESENT. STAY CALM, WE’RE DOING EVERYTHING WE CAN AND I WILL UPDATE YOU

AS SOON AS MORE INFORMATION BECOME AVAILABLE.

MESSAGE ENDS

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 14 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

MESSAGE 8 - Evacuation of Muster Point Message

[USE PRE-MESSAGE IN MESSAGE 10 PRIOR TO THIS]

ATTENTION ALL PERSONNEL

ATTENTION ALL PERSONNEL

THIS IS AN EMERGENCY MESSAGE

THIS IS AN EMERGENCY MESSAGE

THIS IS THE [SPECIFY] SPEAKING

ALL STAFF AT THE [SPECIFY] MUSTER POINT SHOULD LEAVE THEIR MUSTER POINT IN AN ORDERLY FASHION AND RELOCATE TO THE

[SPECIFY] MUSTER POINT USING THE FOLLOWING ROUTE [SPECIFY]

I REPEAT, ALL STAFF AT THE [SPECIFY] MUSTER POINT SHOULD LEAVE THEIR MUSTER POINT IN AN ORDERLY FASHION AND

RELOCATE TO THE [SPECIFY] MUSTER POINT USING THE FOLLOWING ROUTE [SPECIFY]

ON ARRIVAL YOU SHOULD REPORT TO THE SENIOR PERSON IN

CHARGE AND RE-MUSTER.

MESSAGE ENDS

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 15 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

MESSAGE 9A– Standard Comfort Message - Relating to Staff and Families

– [USE PRE-MESSAGE IN MESSAGE 10 PRIOR TO THIS]

Note – messages 9a and 9b maybe used together or separate, depending on

situation and amount of information.

ATTENTION ALL PERSONNEL

ATTENTION ALL PERSONNEL

THIS IS AN EMERGENCY MESSAGE

THIS IS AN EMERGENCY MESSAGE

THIS IS (NAME ) THE EMERGENCY CONTROLLER SPEAKING

A [ SITE INCIDENT / OFF SITE NUCLEAR EMERGENCY ] HAS BEEN DECLARED IN RESPONSE TO AN INCIDENT THAT HAS OCCURRED ON

(INSERT PLANT IDENTIFICATION) OUR EMERGENCY TEAMS ARE DEPLOYED AND I’D LIKE TO SHARE

WITH YOU THE INFORMATION WE HAVE SO FAR.

:- INTENTIONS REGARDING MUSTERED STAFF (SPECIFY)

(SUGGESTED WORDS ARE: “WITH REGARDS TO YOURSELVES, MUSTERED STAFF IT IS MY INTENTION FOR YOU TO REMAIN AT YOUR

MUSTER STATIONS UNTIL WE ARE IN A POSITION TO MAKE AN INFORMED DECISION ON THE BEST COURSE OF ACTION. WE ARE AWARE OF THE NEED TO REMAIN MINDFUL OF YOUR SAFETY AND

WELFARE AS WE RESOLVE OUR CURRENT CHALLENGES”)

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 16 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

:- WITH REGARDS TO FAMILY / FRIENDS OUTWITH THE STATION (SPECIFY)

(SUGGESTED WORDS ARE: “IN RELATION TO OUR FAMILY AND FRIENDS OFFSITE I CAN ASSURE YOU THAT THE SITUATION IS

UNDER CONTROL WITH ONLY THOSE WITHIN THE DETAILED EMERGENCY PLANNING ZONE SHELTERING IN

ACCORDANCE WITH OUR EMERGENCY ARRANGEMENTS.”)

ALL STAFF SHOULD REMAIN AT THEIR MUSTER POINTS AND FOLLOW THE INSTRUCTIONS OF THE SENIOR PERSONS PRESENT.

STAY CALM, WE’RE DOING EVERYTHING WE CAN AND I WILL UPDATE

YOU AS SOON AS MORE INFORMATION BECOMES AVAILABLE.

MESSAGE ENDS

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 17 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

MESSAGE 9B – Standard Comfort Message – Situation Update (Plant Status & Casualties)

NOTE – MESSAGES 9A AND 9B MAYBE USED TOGETHER OR

SEPARATE, DEPENDING ON SITUATION AND AMOUNT OF INFORMATION.

[USE PRE-MESSAGE IN MESSAGE 10 PRIOR TO THIS]

ATTENTION ALL PERSONNEL

ATTENTION ALL PERSONNEL

THIS IS AN EMERGENCY MESSAGE

THIS IS AN EMERGENCY MESSAGE

THIS IS [SPECIFY] THE EMERGENCY CONTROLLER SPEAKING

A [ SITE INCIDENT / OFF SITE NUCLEAR EMERGENCY ] HAS BEEN

DECLARED IN RESPONSE TO AN INCIDENT THAT HAS OCCURRED ON [SPECIFY]

OUR EMERGENCY TEAMS ARE DEPLOYED AND I’D LIKE TO SHARE

WITH YOU THE INFORMATION WE HAVE SO FAR.

- EXTENT OF THE PROBLEM [SPECIFY]

- EMERGENCY SERVICES RESPONSE [SPECIFY]

- DETAILS ON ANY CASUALTIES [SPECIFY]

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 18 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

- ACTIONS UNDERTAKEN BY EMERGENCY TEAMS [SPECIFY]

- ACTIONS PLANNED TO BE UNDERTAKEN [SPECIFY]

- INTENTIONS REGARDING MUSTERED STAFF [SPECIFY]

ALL STAFF SHOULD REMAIN AT THEIR MUSTER POINTS AND FOLLOW THE INSTRUCTIONS OF THE SENIOR PERSONS PRESENT. STAY

CALM, WE’RE DOING EVERYTHING WE CAN AND I WILL UPDATE YOU AS SOON AS MORE INFORMATION BECOME AVAILABLE.

MESSAGE ENDS

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 19 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

MESSAGE 10 – Pre Message

[TO BE USED 30 SECONDS BEFORE ALL NON DECLARATION MESSAGES]

ATTENTION ALL PERSONNEL

ATTENTION ALL PERSONNEL

PLEASE STANDBY FOR A MESSAGE FROM THE EMERGENCY

CONTROLLER

PLEASE STANDBY FOR A MESSAGE FROM THE EMERGENCY CONTROLLER

MESSAGE ENDS

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 20 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

MESSAGE 11 - Local Fire Alarm Message

ATTENTION ALL PERSONNEL

ATTENTION ALL PERSONNEL

THIS IS AN EMERGENCY MESSAGE

THIS IS AN EMERGENCY MESSAGE

THIS IS [SPECIFY] THE CONTROL ROOM SUPERVISOR, A LOCAL FIRE

ALARM HAS SOUNDED IN THE [SPECIFY]

ALL STAFF, IN THE AFFECTED AREA, I REPEAT

ALL STAFF, IN THE AFFECTED AREA, ARE TO GO TO THEIR EXTERNAL MUSTER POINT SHUTTING DOORS AND WINDOWS ON ROUTE.

THE EXTERNAL MUSTER POINT(S) [IS/ARE] LOCATED AT THE,

[SPECIFY AS APPROPRIATE *] *SOUTH WEST TURNSTILE

*OUTSIDE THE MECHANICAL WORKSHOP *OUTSIDE THE WORK EXECUTION CENTRE

*OUTSIDE THE OPS MESS ROOM *THE NORTH CONTRACTORS COMPOUND

EVACUATED STAFF ARE TO STAY AT THEIR MUSTER POINT WITHOUT

EXCEPTION AND AWAIT FURTHER INSTRUCTIONS.

OTHER STAFF NEED NOT MUSTER BUT MUST STAY CLEAR OF THE [SPECIFY] AND THE SURROUNDING AREA.

MESSAGE ENDS

[REPEAT MESSAGE AFTER FIVE MINUTES]

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 21 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

MESSAGE 12 – Call for Persons Not Mustered Message

[USE PRE-MESSAGE IN MESSAGE 10 PRIOR TO THIS]

ATTENTION ALL PERSONNEL

ATTENTION ALL PERSONNEL

THIS IS AN EMERGENCY MESSAGE

THIS IS AN EMERGENCY MESSAGE

THIS IS THE [CONTROL ROOM SUPERVISOR / EMERGENCY ADMINISTRATION OFFICER] SPEAKING

THE FOLLOWING PERSONS ARE NOT RECORDED AS HAVING

MUSTERED AND NEED TO CONTACT THE [ECC/CCR] IMMEDIATELY

THE NAMES ARE [SPECIFY]

I REPEAT THE NAMES ARE [SPECIFY]

IF YOUR NAME IS ON THIS LIST OR YOU KNOW THE LOCATION OF A

PERSON ON THIS LIST THEN PLEASE PHONE THE [ECC/CCR]

IMMEDIATELY ON [SPECIFY]

MESSAGE ENDS

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 22 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

8.2 Procedure for Assessing the Need for the Issuing of Potassium Iodate Tablets to Persons on Site

1. Introduction

The consumption of stable iodine can contribute to a reduction in radiation dose to the thyroid when exposure to radioactive iodine occurs. The Health Protection Agency Centre for Radiation, Chemical and Environmental Hazards (HPA-CRCE)1 has advised that the risks associated with the administration of stable iodine are very small.

The effectiveness of the dose reduction is dependent on how soon after the release the stable iodine is administered and also on how long the release continues. The benefit from taking it is due to the fact that the stable iodine saturates the thyroid gland, thereby preventing the uptake of radioactive iodine.

For the maximum benefit to be obtained, it is desirable that stable iodine be taken just before the time of exposure, when almost complete blocking (>90%) can be achieved. However, even if the consumption of the stable iodine was delayed for 5½ hours, the potential reduction in the radiation dose to the thyroid would still be about 50%.

The decay of the blocking effect is relatively slow and in certain circumstances it may be appropriate to extend that blocking effect by repeated dosages.

2. Criteria for Taking Iodate Tablets

Instructions to issue potassium iodate tablets will be given in the event of the following conditions:

CONDITION PERSONS REQUIRED TO TAKE

IODATE TABLETS

(i) OFF SITE NUCLEAR EMERGENCY

ALL PERSONS ON SITE; ALL PERSONS ATTENDING SITE – IMMEDIATELY AFTER THE DECLARATION.

(ii) SITE INCIDENT INVOLVING A LOCALISED RELEASE OF RADIOACTIVITY FROM IRRADIATED FUEL.

ALL EMERGENCY TEAM MEMBERS ENTERING DAMAGE AREA, MEMBERS OF THE EMERGENCY SERVICES TO TAKE TABLETS BEFORE EXPOSURE. THE EMERGENCY HEALTH PHYSICIST SHOULD BE CONSULTED REGARDING THE NEED TO ISSUE TABLES TO OTHERS ON SITE.

(iii) ANY CONDITION IN WHICH THE EMERGENCY CONTROLLER CONSIDERS BLOCKING OF THE THYROID GLAND FROM INTAKE OR RADIOIODINES IS NECESSARY.

ANY PERSON CONSIDERED TO HAVE TAKEN IN, OR WHO MAY TAKE INTO THEIR BODY, RADIOIODINES BY INJECTION, INHALATION OR INGESTION.

1 Formerly the National Radiological Protection Board (NRPB).

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 23 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

Issue of potassium tablets is automatic on the declaration of an Off Site Nuclear Emergency. In other circumstances only the Emergency Controller or Shift Manager may, after consultation with the Emergency Health Physicist, authorise issue of potassium iodate tablets; and in the case of (iii) above, if time permits, after consultation with a Company Occupational Health Physician.

3. Repeat Dosages

In the event of potential further exposure, (i.e. subsequent tours of duty as an Emergency Team member in the event of prolonged releases or persistent hazard), the dosages of potassium iodate tablets may need to be repeated. The Company Occupational Health Physician must always be consulted, and will advise if repeat dosages are considered necessary giving instructions of the frequency, quantity of tablets to be taken and any limitations.

4. Instruction Card – Personnel on Site

POTASSIUM IODATE TABLETS INSTRUCTIONS TO PERSONNEL IN AN EMERGENCY

This note is to be given to all personnel on site at the time of issue of potassium iodate tablets.

THE USE OF THESE TABLETS HAS BEEN ADVISED BY THE CHIEF MEDICAL OFFICER, EDF ENERGY NUCLEAR GENERATION LTD, THEY WILL PROTECT YOUR HEALTH IF USED AS DIRECTED.

TAKE THE FOLLOWING DOSE IMMEDIATELY

ADULTS (INCLUDING PREGNANT WOMEN AND WOMEN WHO ARE BREAST FEEDING) TWO TABLETS

(CHILDREN AGED 3-12 YEARS ONE TABLET) (CHILDREN AGED UNDER 3 YEARS HALF A TABLET)

THE TABLETS ARE TO BE TAKEN WITH WATER, THEY ARE TO BE TAKEN ONLY ONCE UNLESS DIRECTED OTHERWISE BY A COMPANY MEDICAL OFFICER.

The only people who should not take the tablets are those who knew that they are allergic to iodine and those who suffer from the very rare conditions of Hypocomplementaemic Vasculitis or Dermatitis Herpetiformis.

Your doctor will have told you if you suffer from one of these conditions. Further advice is available from Occupational Health

5. Site-Stocks of Iodate Tablets

The number of stocks of tablets and their locations is as follows (Site Specific):

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 24 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

6. Buffer Stocks

A national buffer stock of potassium iodate tablets is stored at strategic locations around the UK and is managed by the Department of Health. The arrangements for accessing these stocks in the event of an Off Site Nuclear Emergency are managed via the Strategic Co-ordination Centre.

7. Casualties

Potassium Iodate Tablets should not generally be administered to casualty – see section 12.2.

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 25 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

8.3 Transfer of Emergency Control Centre

1. Introduction

The radiological or security conditions in the main Emergency Control Centre may render it untenable, in this eventuality evacuation to the alternative ECC at (Site Specific) will be effected in accordance with the following procedures:

2. Prior Arrangement

2.1 On arrival at ECC Health Physics Support Officer to Check Radiation and CO2 readings. If greater than 0.5% CO2 or 10 µSv/hr* the Emergency Control Centre to be relocated to the alternative facility.

*If potassium iodate tablets have NOT been taken then staff could potentially be exposed to 1mSv in an hour from isotopic mix - every effort should be taken to relocate or issue KI if greater than 0.5µSv/hr

2.2 Contact the Shift Manager and the Gatehouse Security staff and advise them of the intention to evacuate the Emergency Control Centre and nominate the alternative location that it is intended to use.

2.3 Contact a responsible person at the chosen alternative location or send a responsible person there, and give instructions for clerical and communication equipment to be made available. (Note: at some stations this may require the transfer of BT telephone lines).

2.4 Obtain additional security guards, by call in if necessary, to provide security services to the Alternative ECC.

2.5 Inform the CESC of the transfer. If the CESC is not already established when possible advise the CESC of this transfer and of any new BT telephone number.

2.6 Arrange the necessary transport to convey the Emergency Control Centre staff to the alternative centre, including Medical Decontamination Centre staff if necessary.

2.7 Contact all mobile radio stations on the operating channel, advise them of the move, and instruct on the alternative control arrangements until the new Emergency Control Centre is established.

2.8 Have the clerical staff in the Emergency Control Centre collect all essential information and data ready for transport to the alternative centre, i.e.: copies of white boards, logs, muster results

2.9 Make arrangements to re-direct the Station switchboard.

2.10 Check with ECC Officers and, if all preparations are complete, give instructions to move to the alternative centre, notifying the Shift Manager that evacuation is taking place.

2.11 Make a Public Address announcement about the change.

3. Post Movement Arrangements

3.1 Advise persons notified (2.2, 2.3, 2.5, 2.7 and 2.11 above) that the alternative Emergency Control Centre is established and confirm the alternative working arrangements.

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 26 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

4. Criteria for Evacuation of an Operational ECC

4.1 An ALARP risk assessment is required on the benefits achievable from remaining in the ECC and likely exposures

Note: If staff HAVE taken KI and in the absence of an air concentration measurement, the dose rate measured is 10-20 µSv/hr then staff could potentially be exposed to 1mSv/hr CEDE- it would be up to the Health physicist to decide if the emergency centre should be evacuated - every effort should be taken to evacuate if greater than 20µSv/hr as likely to exceed public IRR limit for public e.g. emergency services etc

4.2 An initial Control Dose limit for ECC staff 10 mSv over first 10 hours is advised for EDF Energy staff, emergency services should be consulted and made aware of risks

4.3 Assume Potassium Iodate tablets taken to mitigate the iodine contribution the Caesium effects become relevant for 4.2 above. The use of respirators by ECC staff is considered impracticable for prolonged work as it makes tele communication etc, difficult.

4.4 Assume a CEDE of approximately 1 mSv/h of inhalation, from 1.5 x 105 Bq/m3 isotopes of caesium (which is estimated to give dose reading of approximately 10-20µSv/hr including the contribution from isotopes of iodine)

4.5 During First 10 hours

IF dose rate > 20µSv/hr EVACUATE unless air sample results taken near the ECC indicate this may be relaxed.

Whilst this should be taken as an absolute level the Health Physicist should make conservative decisions regarding occupancy as radiological conditions change.

4.6 If CO2 become >0.5% consult with Duty Emergency Health Physicist about long term occupation of ECC.

4.7 After First 10 hours

The situation should be reassessed in the light of past and prevailing radiological conditions, availability of new ECC staff, and the possible need to comply with the subsidiary IRR dose limits applicable to certain female; workers or if applicable the limits specified for Severe Accidents (see section 10.5).

5. Location

The Alternative Emergency Control Centre is located on (Site Specific) to the

(North/East/South/West (Site Specific) from Station) of the Station (Site Specific).

(Provide directions from Site) (Site Specific)

(Provide directions from Main Route to Site) (Site Specific)

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 27 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

8.4 Notification of External Organisations and Station Emergency Personnel

1. Introduction

The communications chains for the notification of external organisations and Station emergency Personnel that a Site Incident or Off Site Nuclear Emergency has been declared, is presented in figures 1, 2 and 4 of the Emergency Plan. These notifications calls are made to designated telephone numbers and will be by the use of Standard Messages which will initiate action within the external organisation or by Station Emergency Personnel regardless of the time of day or day of year.

The Station makes all notifications that are site specific i.e. 999 calls, calls to local industry etc. (some may be carried out by the Police); calls that are generic in nature are made by the duty officer at the Barnwood Alert Centre when notified by the Station.

2. Standard Messages

The Emergency Controller or Shift Manager in his absence will compose the standard

message from the following alternatives:

THIS IS A GENUINE NOTIFICATION* “THIS IS (Site Specific) POWER STATION. WE ARE INFORMING YOU OF A SITE INCIDENT */ OFF SITE NUCLEAR EMERGENCY* AT ................... (TIME)** AT (Site Specific) POWER STATION(1) (WIND DIRECTION FROM .......... DEGREES) # FOR YOUR ACTION” (** INCIDENT START TIME) (* DELETE AS NECESSARY) (# OFF SITE NUCLEAR EMERGENCY ONLY) See Section 4 for Exercise words

3. Actions

3.1 Notification calls always made from the Central Control Room

In the event of a Site Incident or Off Site Nuclear Emergency the Shift Manager will instruct a member of the Central Control Room staff to undertake the duty of emergency telephonist and relay the notification message without delay to:

(i) Emergency Services.

(ii) Adjacent Nuclear Site to provide agreed services.

(iii) Station Standby Emergency Staff.

(iv) Company notification system.

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 28 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

The notification will be made in accordance with the list, Appendix EP/8.4/1 for a Site Incident (only including the Fire & Rescue Service and Ambulance services as directed by the Shift Manager), and in accordance with the list, Appendix EP/8.4/2 for an Off Site Nuclear Emergency (when the Fire & Rescue Service and Ambulance Service will be notified regardless of whether there is a fire or there are any casualties).

A Confirmatory call should be made to the Fire & Rescue Service and Ambulance Service by 999 confirming that notification by the Police has been received and providing additional information on the extent of the Off Site Nuclear Emergency unless attendance at site has already been achieved.

3.2 Notification calls made from either the Central Control Room or Emergency Control Centre

The Central Control Room staff undertaking the calls itemised in 3.1 above will continue to make the remaining calls on the appropriate Notification List until the Emergency Administration Officer is in post at the Emergency Control Centre and contacts the Central Control Room and formally takes over the completion of the Notification List.

3.3 If the status is changed from a Site Incident to an Off Site Nuclear Emergency, cease the Site Incident list of calls, and start at the beginning of the Off Site Nuclear Emergency call list.

3.4 When making calls ensure that the duty officer or person listed is contacted and that they acknowledge and understand the message.

3.5 Advise the Emergency Controller when contact cannot be made and continue to repeat calls or make alternative calls as instructed.

4. ONR Call Back

The HSE (ONR) Nominated Inspector will call back to the affected site after notification by the

Alert Centre and request further information. This should be supplied as a matter of urgency.

5. Cancellation

When a Site Incident or Off Site Nuclear Emergency is Cancelled all organisations notified should be informed.

Section 2.4.2 of the Plan gives the responsibilities for Cancellation.

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 29 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

ONR INSPECTORS CALL BACK CHECK SHEET – information likely to be required 1 Time of Call ............................................ 2 Who supplied data ....................................... 3 Site .................................................... 4 Has the APPROVED SITE EMERGENCY PLAN been invoked ....... 5 What state has been declared and when ................... 6 Relevant Plant/Reactor No./Building No. ................. 7 Nature of the

incident............................................................................................................................................ 8 How many killed/injured/contaminated/irradiated......... 9 Plant situation: Cooling Circuit - Breached/intact - size and nature of breach Circulators available main/pony motors Gas pressure and temperature Core Status - Control Rods No. Inserted in each region ......................................................... BCDG - No. in alarm/size of signal/location ............. Fuel temperatures ....................................... Graphite temperatures ................................... State of reactor before the incident starting up/steady state/shutting down Fuel burn-up MWD/Te Diesel Generators - No. damaged/in use/available CO2 stocks on site Te............ On order TE ........... Iodine Absorption Plant available/in use.

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 30 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

10 Health Physics Data : Wind direction from ............Speed.........m per sec Weather conditions and dispersal category.....raining?... Size and nature of any release........Bq Rate.......Bq/hr Isotopes ................................................ 11 Who is the Emergency Controller on Site ................. 12 Has evacuation been initiated/other countermeasures ..... 13 Has the SCC been activated .......................... 14 Other agencies informed - Police/Fire/LA/Government Departments?

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 31 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

8.5 Emergency Organisation Staffing Resources

1. Purpose

Emergency plan actions have been designed against a minimum staffing resource and to be self sufficient for 60 minutes. This section provides information on the minimum staffing levels required to provide the initial emergency response to enable the Emergency Controller to quickly assess the resilience of the emergency organisation to cope with the event.

2. Scope

The emergency plan staffing resources stated here are derived for a reasonable foreseeable accident involving a reactor event and release of radioactivity. For other events the resources should be managed to provide additional expertise or staffing levels as required.

3. Practice

3.1 The resources for the emergency plan are provided from:

Staff on shift available immediately after the event occurs;

Day staff on standby available within 60 minutes

Emergency services available when notified

3.2 Shift Minimum Emergency Role Staffing

(i) A record of the current shift staffing is available from the [site specific e.g. CCR] indicating cover for emergency roles which will meet or exceed the minimum manning.

Lo

cati

on

Po

st

Gen

eri

c

[Sta

tio

n]

SM 1 1

MCRS 1 1

Desk 2 2 CCR

Total 4 4

Controller 1 1

Asst 1 1

BAECO 1 1

First Aid 1 1

ACP

Total 4 4

IRT

Total 12 ??

ESLO 1 1

Roll Call 1 1 Security*

Total 2 2

TOTAL 22

* these are the roles to be covered by security in support of the emergency response the minimum staffing for security is determine by ONR (CNS) requirements

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 32 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

(ii) The [site specific] team leader maintains the staffing level for the next 24 hour shift cycle. Any changes in staffing levels during this period will be communicated to the CCR

(iii) Part of the shift handover procedure is to ensure our that the emergency role responsibility has being passed on effectively

3.3 Standby Rota

(i) The current planned rota for staff is available [site specific e.g. intranet]

(ii) The following table indicates the minimum emergency organisation roles resource from day staff on Standby [site specific]

Post Names

Emergency Controller

Assist Emergency Controller

Health Physicist

Reactor Physicist

Admin Officer

Chemist

Support Officer

SERT

Off Site Survey

Communication Co-ordinator

(iii) The list of personnel currently on the duty is available in the CCR (i.e. including changes/swaps etc)

(iv) Staff on standby for the current week is displayed [site specific e.g. reception]

(v) The duty Rota week starts and ends on [site specific]. Duty change has been completed when the emergency pager/information has been provided to the oncoming person.

(vi) If changes in personnel occur during a duty week it will be notified to the CCR including the name of the person who has agreed to be on duty.

3.4 Emergency Services Personnel

(i) Following the declaration of an Off site Nuclear Emergency the following emergency services resources will be deployed to site and operate from the following locations [site specific]

ECC ACP On site * COMMENTS

POLICE 1 OFFICER NIL NIL Escort required

FIRE 1 OFFICER INCIDNET COMMANDER

X appliances Y staff

Escort required

AMBULANCE 1 OFFICER 1 OFFICER /PARAMEDIC

X Ambulances Y staff

Escort required

* per determined response - included any resources held at off site RVP’s [Rendezvous Point] if appropriate

(ii) For a site incident declaration the emergency services will attend site of if requested and should be deployed to: [site specific]

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 33 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

3.5 Calling In Additional Emergency Personnel

(i) In addition to the Standby Duty Emergency Officers it may be necessary to call in additional personnel when a Site Incident or an Off Site Nuclear Emergency is declared outside normal working hours.

(ii) These supporting staff’s services may be required immediately or within a few hours depending on the event to provide additional specialist services and supplement the existing Emergency Teams. Staff are subdivided into three groups:

(a) Off duty Standby staff will be contacted by telephone or radio pager if personally issued; or

(b) Those that have been issued with radio pagers and will respond by coming to site on receipt of an alert call but are not on a Standby Duty Rota.

(c) Those who have not been issued with radio pagers who may attend site on receipt of an emergency alert call via telephone.

(iii) The staff will attend site and help supplement existing teams, Emergency Controller should anticipate where resources should be deployed for best effect. E.g. :

a. Asst Emergency Controller

b. ECC Admin support

c. Reactor Physicist to support CCR

d. ACP Health Physicist

e. CCR Admin support

f. SERT to support ACP operation

(iv) Pre Site Incident Or Off Site Nuclear Emergency up to date alphabetical lists (not part of this document) of telephone numbers, radio pagers and addresses of all station staff, cross-referenced to emergency scheme skills and shifts will be available to shift staff in CCR and ECC

(v) Call In Actions - The Shift Manager or Emergency Controller (or through the Emergency Administration Officer when on site) will instruct the Emergency support staff to call in further additional staff as required.

(vi) The Shift Manager or Emergency Administration Officer will deploy drivers to collect additional staff as required.

(vii) The CESC support officer can be used to provided additional support to call in staff and access support from other sites

3.6 Emergency Response Staff Change of Shift

(i) In the event of a Site Incident or Off Site Nuclear Emergency, the Emergency Controller will have to consider when to replace emergency organisation personnel and the shift on duty. Such a decision will have to be made early, to ensure that oncoming shift staff are informed and provided with access to the site.

(ii) The Emergency Controller will have to ensure that a comprehensive handover takes place between the outgoing and incoming shifts.

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 34 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

3.7 Support For Staff

(i) After having been involved in any serious incident, staff may require follow up support. Staff relieved of their duties, either during or after a serious incident could be taken in appropriate transport to a suitable off site location where they can undergo full debriefing prior to release home. It will be the responsibility of the Emergency Controller to ensure that this is undertaken effectively and that staff can contact their families at all times, with assistance from the CESC if necessary.

(ii) n the longer term, staff involved in serious incidents may require some form of ‘post traumatic stress counselling’. Such counselling is best started early after the incident: the Company Medical officer will advise sites as to how best to set up this service.

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 35 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

8.6 Advising the Police on Counter Measures

1. Introduction

The criteria upon which the advice on countermeasures are based for protection of the public from exposure to radiation hazards is the guidance presented to Government by the Health Protection Agency Centre for Radiation, Chemical and Environmental Hazards (HPA-CRCE)2 in The Documents of the NRPB Vol. 1 No 4 1990 – Board Statement on Emergency Reference Levels

RECOMMENDATIONS FOR COUNTERMEASURES FOR MEMBERS OF THE PUBLIC

Recommended ERLs for urgent countermeasures

Dose Equivalent level (mSv) Countermeasure Body Organ

Lower Upper

Sheltering Evacuation Stable iodine

Whole body Thyroid, lung, skin Whole body Thyroid, lung, skin Thyroid

3 30 30 300 30

30 300 300 3000 300

2. Countermeasure Advice

2.1 Automatic countermeasures

In the early phase of an Off Site Nuclear Emergency the Emergency Controller (or Shift Manager

in his absence) is responsible for advising the Police on the potential radiological hazard off site, and making recommendations on the urgent countermeasures which should be implemented to protect the public based on the HPA-CRCE guidance. When the CESC is fully operational this responsibility is transferred to the CESC Controller.

An agreement has been established with the [local health authority] authorising the Emergency Controller to advise the public and personnel on site when appropriate to take potassium iodate tablets. This will enable the countermeasures of sheltering and taking of potassium iodate tablets to be automatically introduced on the declaration of an Off Site Nuclear Emergency throughout the DEPZ based on the principle for the precautionary use of countermeasures to protect the public.

This is achieved by the EDF Energy telephone warning system will be activated by the Communication Co-ordinator from the CESC to inform residents in the DEPZ registered on the system to shelter, take potassium iodated tablets which have been pre distributed and listen to local news for further information.

2 Formerly the National Radiological Protection Board (NRPB).

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 36 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

2.2 Action Levels for Additional Countermeasure Advice

Further advice will be issued based on early measurements of the off site radiological hazard and linked to a simple action level. The action level is set such that there should be sufficient time for the countermeasures to be implemented for a dose greater than the lower ERL for the countermeasure to be averted.

If off site measurements indicate a total Beta/Gamma airborne activity of 105Bq/m3 or greater, then, in the absence of gamma spectrometry information, it will be assumed a person exposed to this concentration over a period of 6 hours would receive a committed dose to the thyroid of 300mSv (the HPA-CRCE lower emergency reference level (ERL) for evacuation). Evacuation would, in the absence of any other countermeasures being introduced be justified Exposure time to receive this dose will increase or decrease in proportion to the concentration of airborne radioactivity.

a) The Emergency Controller will, on being advised of a total Beta/Gamma airborne activity

in excess of the action levels stated in section 2.2 (above), advise the Police of the need to implement countermeasures for all persons exposed in the affected areas. Unless the release has or will imminently cease or the isotopic composition indicates that the dose averted by the actions will not approach the lower ERL for the justification of the relevant countermeasure.

b) If an alpha air activity greater than 30 Bq/m3 above natural background is measured, then the actions above (possibly excluding the issue of potassium iodate tablets) will be initiated.

c) The Emergency Controller may advise evacuation of the public, and/ or consideration of potassium iodate tablets, before the above action levels are reached purely as a precautionary measure, in a situation where it is considered that the integrity of the plant’s safety barriers have been so seriously degraded that there is a significant probability of a release of radioactivity for which urgent countermeasures could result in an averted dose above the lower ERLs for evacuation.

d) Similarly the Emergency Controller may advise evacuation of the public, and/ or consideration of potassium iodate tablets, before off site survey results have confirmed that the above action levels have been reached if the Perimeter Fence Monitoring System and plant conditions together provide unambiguous evidence that a substantial release is occurring.

2.3 Advice on Sheltering as a Countermeasure

(a) Sheltering (advising the public to remain indoors with doors and windows closed and ventilation systems turned off) may have advantages over evacuation. In most cases it is anticipated that the Emergency Controller should consider the following in determining whether sheltering should be advised:

(i) Can sheltering be initiated in affected areas before the inside of buildings are likely to be affected by the passing plume?

(ii) Is the duration of the release likely to be less than the time to have completed evacuation of affected areas?

(iii) Can the probability of the off site radiological conditions worsening be discounted?

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 37 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

If the Emergency Controller is confident that this answers to all these questions is ‘yes’, then

sheltering may be advised instead of evacuation in the affected sectors.

(b) Sheltering and administration of potassium iodate tablets would be justified, if offsite measurements indicate a total Beta/Gamma airborne activity of 104Bq/m3 or greater but less than 105Bq/m3.

(c) The effectiveness of sheltering is dependent on the construction of the building.

It should be assumed:

• tents provide no long term protection

• caravans only provide a 30% protection relative to a brick built dwelling

(d) If sheltering has been advised, the Emergency Controller should ensure that members of the public in affected sectors receive advice from the Police to open doors and windows and (to ventilate the building) after it is confirmed by monitoring that the release has terminated and the plume has passed.

2.4 Advice on Potassium Iodate as a Countermeasure

a) Stable iodine is only effective for blocking the thyroid gland from the uptake of radioactive iodine

b) Potassium Iodate tablets should be with water and the dosage should follow NHS guidance for relevant age groups. ( section 8.1)

c) To avert 80%+ of the dose for the average adult stable iodine must be administered within 1-2 hours

d) To avert 50% of the dose for the average adult stable iodine must be administered within 2-6 hours

3. Predicted Sources of Exposure

3.1 The characteristics of releases from potential emergency situations are:

a) the most significant source of radiological exposure is likely to be the inhalation of radioactive materials leading to radiation doses to the thyroid (radioactive iodine species) or to the lung (other fission products such as Ruthenium – 103 and Ruthenium – 106);

b) the direct radiation doses either from the plume or from activity deposited on the ground are likely to be much less important;

c) the inhalation hazard will only arise during the passage of the plume. The duration will depend on the nature of the fault.

3.2 The Emergency Controller will give priority to the assessment of the inhalation hazard off site

followed by the hazard arising from direct radiation and obtain the guidance of the Emergency Health Physicist in interpreting the results of measurements.

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 38 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

4. Radiological Information

4.1 The Emergency Controller in making the decision on the advice to the Police on countermeasures, will assess the available information from:

(i) Wind speed and direction measurements and any forecast change.

(ii) Perimeter Fence Gamma Monitor measurements.

(iii) Gross beta/gamma activity on Maypack filters from Off site and On-site air samples.

(iv) Potential doses to the public computed from gamma spectrometric analysis of Maypack air sample filters.

(v) External gamma radiation measurements taken by the On and Off site Survey Teams; and

(vi) Indication from plant conditions on the foreseeable duration and severity of the release and/or the level of radioactivity in the primary coolant circuit of the reactor whether breached or intact.

4.2 Off Site Monitoring

A minimum of two suitably equipped Off Site Survey vehicles, will be deployed immediately on the declaration of a Site Incident or an Off Site Nuclear Emergency. Having contacted the Central Control Room or ECC, the teams will proceed initially to pre-determined down wind sampling points where they will take air samples and radiation dose rate measurements. The results of these measurements will be promptly transmitted.

As a matter of urgency air samples will be taken to a laboratory for further assessment by gamma spectrometry as directed by the Emergency Health Physicist. The results will be communicated to the ECC or CESC to enable an assessment of any release and to recommend any necessary actions.

When the CESC has been declared operational the responsibility for directing the off site survey will be transferred to the CESC Health Physicist.

4.3 Assessment

(a) The initial assessment of the severity potential hazard to the public will be made on the total Beta/Gamma activity of special air samples counted by vehicle-borne equipment.

(b) High resolution gamma spectrometry measurements of off site air samples will allow a determination of the isotopic composition of the release to be made. This information will allow a realistic assessment of potential radiation dose to be made thus allowing any earlier advice formulated without information on isotopic composition to be confirmed or modified.

(c) Total Alpha activity will be measured on all the samples used for Gamma spectrometry.

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 39 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

5. Prior Information to the Public in the DEPZ

Under the REPPIR information in the form of a calendar has been provided to the residents in the DEPZ on the actions to take in the event of an off site nuclear emergency, to the effect that they should

(i) go indoors, close external doors and windows, switch off any ventilation fans; and

(ii) switch on the radio and tune to Local Radio or TV if they become aware (by any means) that an Emergency has been declared but have not received authoritative advice or instructions from the Police.

Once confirmation the EDF Energy Telephone warning system has been activated successfully and information is in the media it should be assumed therefore actions may be followed in all sectors although no allowance for such actions should be made in determining the need for positive reinforcement of advice on countermeasures to those in sectors affected .

The Emergency Controller should consider with the Police Liaison Officer what advice should be given to those persons within the detailed emergency planning zone but not in the affected sectors and arrange for such advice to be broadcast on the appropriate channels as soon as reasonably practicable.

Priority must always be given to ensuring the implementation of appropriate additional countermeasures (if required) in affected sectors.

6. Method of Presentation of Recommendation and Advice to the Police

6.1 In addition to verbally presenting the advice to the Police Liaison officer at the Emergency Control Centre and illustrating the area to which the recommendations will be applied, advice will be given to the Police Liaison Officer in written form on form EP/8.6/1. This will help ensure that the Police Liaison officer relays the Emergency Controller’s recommendations verbatim rather than the Police Liaison Officer transcription and interpretation of the information.

6.2 The extent of the area which additional counter-measures are recommended should be

described in words and sketched on a map.

6.3 The Emergency Controllers advice will be transmitted to the Police Control or SCC by fax.

6.4 The provision of initial advice is important. The following words should be used on form EP8.6/1 in the ‘Evacuation box’:

“MONITORING OF THE DOWNWIND SECTORS IS IN PROGRESS. AUTOMATIC COUNTERMEASURES OF SHELTERING AND TAKING POTASSIUM IODATE

TABLETS ARE BEING ADVISED TO THE PUBLIC IN THE DEPZ.

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 40 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

EXPERT ADVICE FORM E 8.6

OFF SITE COUNTERMEASURE ADVICE for Public protection

Incident Type SITE INCIDENT OFF SITE NUCLEAR EMERGENCY

Company Station

Declared at : Declared on / /

Current Release/Plant Situation • There has not been any radioactivity released from site. The general public are not at any risk and do not need to take precautions.

There has been a radioactivity released from site.

Short Term/ Long Term Prognosis • There has been / is / exists a potential for, a limited / significant release of radioactivity off site*.

• Conditions are under control and no / no further releases are likely

Meteorological Situation ( Current/Forecast)

The Current wind direction is FROM _____________ towards sectors _________________ The Forecast wind direction is FROM _____________ towards sectors _________________

Principle exposure route and isotopes o The principal exposure route is inhalation / Cloud (Direct) / Deposition (Direct) / Ingestion * o The principal isotopes associated with normal operation, start up, shutdown, other specify o The dose of the thyroid / lung / whole body is most significant

Urgent Countermeasures recommended AUTOMATIC COUNTERMEASURES OF SHELTERING AND TAKING POTASSIUM IODATE TABLETS FOR THE PUBLIC IN THE DEPZ HAVE / HAVE NOT BEEN ISSUED*

Shelter in sectors – Evacuation in sectors -

Additional Advice/Information

Persons residing outside these areas do not need to take any action at this time*

Countermeasure Advice issued at: ________________ Date: ________________________ By: (Name, block capitals) _______________________ Signed: _______________________ EMERGENCY CONTROLLER [* = delete as necessary]

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 41 of 45

edfenergy.com

NOT PROTECTIVELY MARKED/RESTRICTED/CONFIDENTIAL

8.7 Guidance on Declaration Conditions

1. Introduction

The first responsibility of EDF Energy Nuclear Generation Ltd is to ensure that any hazardous condition requiring the initiation of an emergency response is recognised and the appropriate declaration made.

The declaration conditions are contained in Section 2.3 of the Emergency Plan.

It is therefore imperative that a declaration is made promptly should any of these declaration conditions be met.

2. Site Incident

A Site Incident is defined as “A hazardous condition which is confined in its effects to within the boundary of the site security fence”.

It should be noted that a Site Incident is not limited to events with a radiological hazard. Any serious situation on a site which requires the withdrawal of staff to a safe area, assembly of emergency teams and accounting for any missing persons should be considered a Site Incident. Circumstance may exist where there is a hazard localised to a specific area of the site (e.g. CO2 leak or fire). It is important that staff are alerted to any hazard and that all those who may be at risk are accounted for. This may be achieved by sounding the evacuation alarm for the plant area in question. Site Incident declarations can and should be made for any situation where protection of staff is required and the management of the event assisted. The declaration will mobilise emergency teams trained in fire, rescue, first aid, damage repair, and control. Teams may then enter the affected area in a controlled manner, supported by a well trained, well exercised emergency organisation. The Emergency Controller’s prime consideration in reaching this decision must be the safety of personnel on-site.

3. Off Site Nuclear Emergency

An Off Site Nuclear Emergency is defined as “A hazardous condition which results, or is likely to result, in the need to consider urgent countermeasures to protect the public outside the site security fence from a radiological hazard”. The hazardous condition may be pre-existing or imminent.

The declaration warns all relevant organisation that there is a hazardous condition at the power station which might require the implementation or urgent countermeasures to protect the public.

PROMPT DECLARATION IS VITAL

For an Off Site Nuclear Emergency the declaration does not mean evacuation of the public is necessary. What the declaration does is tell outside organisations to GET READY so that they are in a position to respond rapidly and efficiently to protect the public. A prompt declaration will ensure that their organisation has the resources necessary to implement further countermeasures should they subsequently be advised.

In addition to mobilising the EDF Energy Nuclear Generation Ltd resources to assist the affected station the declaration will result in off site monitoring and establish the magnitude of the release of radioactive material. This will be assessed initially in the ECC where written advice on countermeasures will be given to the police liaison officer using form EP 8.6/1.

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 42 of 45

edfenergy.com

NOT PROTECTIVELY MARKED/RESTRICTED/CONFIDENTIAL

The police will then inform other organisations of the countermeasures advice. All organisations should then deploy their resources as necessary.

When the CESC is operational the CESC Controller will take over from the Emergency Controller responsibility for issuing advice on countermeasures. This advice will be passed to the SCC, initially directly to the Police Gold Commander / Strategic Co-ordinator via video conference with written fax backup using form CESC/1 and subsequently via the Company Technical Advisor (CTA) and then GTA.

In summary the prompt declaration of an Off Site Nuclear Emergency will mobilise the resources that would be necessary to implement urgent countermeasures.

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 43 of 45

edfenergy.com

NOT PROTECTIVELY MARKED/RESTRICTED/CONFIDENTIAL

8.8 Off Site Potassium Iodate Tablet Distribution Arrangements

1. Introduction

The Local Health Authority are responsible for ensuring that arrangements exist for the distribution of Potassium Iodate Tablets to the public. This responsibility is contained in the Department of Health Annex to HE(89)8 as modified by the addendum of 5th October 1993.

2. Potassium Iodate Stocks

Off site Potassium Iodate tables and leaflets are stored as follows:

Location Quantity

(Site Specific) packs 100 (Site Specific) packs 10

3. Collection & Distribution

Insert local statement as provided by Health Authority to EPCC. (Site Specific)

4. Prior Authority to Issue

Since potassium iodate tablets are a medical countermeasure, District Directors of Public Health are responsible for authorising their issue. For planning purposes, prior authorisation to EDF Energy Nuclear Generation Ltd will enable plans to be activated without the need to refer specifically to the DPH for authorisation at the time of an accident, and will thus avoid valuable time being lost. The criteria in the Approved Site Emergency Plan will be used.

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 44 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

Appendix EP/8.4/1 Site Incident Notification Message

THIS IS A GENUINE NOTIFICATION. THIS IS .................................. POWER STATION. WE ARE INFORMING YOU OF A SITE INCIDENT AT ….. : ….. HRS AT .......................................... POWER STATION – FOR YOUR ACTION

REF ORGANISATION TELEPHONE

NUMBER TIME Notify

FURTHER INFORMATION

1

POLICE SERVICE

999

Back up comms (Site Specific) FCC Inspector (Site Specific)

FCC Shift Manager (Site Specific)

Always call the Police, pass the following information. � CASUALTIES – Number and seriousness of injuries.

Muster in progress, missing persons known or suspected

� HAZARDS – Present and potential hazards. It is / or is not safe to attend site

� ACCESS – Identify a safe approach to site � LOCATION – State the exact location of the incident � EMERGENCY SERVICES – State those present and

those required. � TYPE – State description of incident.

2 FIRE & RESCUE

SERVICE 999

Do not call if not required, pass the following information. � CASUALTIES – Number and seriousness of injuries.

Muster in progress, missing persons known or suspected

� HAZARDS – Present and potential hazards. It is / or is not safe to attend site

� ACCESS – Identify a safe approach to site � LOCATION – State the exact location of the incident � EMERGENCY SERVICES – State those present and

those required. � TYPE – State description of incident.

3 AMBULANCE

SERVICE 999

Do not call if not required, pass the following information. � CASUALTIES – Number and seriousness of injuries.

Muster in progress, missing persons known or suspected

� HAZARDS – Present and potential hazards. It is / or is not safe to attend site

� ACCESS – Identify a safe approach to site � LOCATION – State the exact location of the incident � EMERGENCY SERVICES – State those present and

those required. � TYPE – State description of incident.

4 EMERGENCY

STANDBY STAFF

GROUP PAGE (Site Specific)

Always set off the pagers, even in normal working hours. Full details on pager instructions, individual pager numbers and other contact details for standby staff are in the Station Emergency Telephone Directory (Site Specific).

5 ADJACENT STATION

(Site Specific)

DIRECT WIRE or

(Site Specific)

(Site Specific)

6 BARNWOOD

ALERT CENTRE

Always call the Barnwood Alert Centre; they will prompt for the information required.

7 OTHER

(Site Specific) (Site Specific)

(Site Specific)

Order has changed

NOT PROTECTIVELY MARKED BEG/SPEC/OPSV/EPG/002/008 Revision 006 Page 45 of 45

edfenergy.com

NOT PROTECTIVELY MARKED

Appendix EP/8.4/2 Off Site Nuclear Emergency Notification Message

THIS IS A GENUINE NOTIFICATION. THIS IS ......... (STATION NAME)....... POWER STATION. WE ARE INFORMING YOU OF A (STATION NAME) OFF SITE NUCLEAR EMERGENCY AT .... : .... HRS ON ........ (STATION NAME)......... POWER STATION. WIND DIRECTION FROM .............. DEGREES – FOR YOUR ACTION

REF ORGANISATION TELEPHONE

NUMBER TIME

NOTIFIED FURTHER

INFORMATION

1

POLICE SERVICE

999

Back up comms (Site Specific) FCC Inspector (Site Specific)

FCC Shift Manager

(Site Specific)

Always call the Police, they will inform the rest of the emergency services during an Off Site Nuclear Emergency. Pass the following information. � CASUALTIES – Number and seriousness of

injuries. Muster in progress, missing persons known or suspected

� HAZARDS – Present and potential hazards. It is / or is not safe to attend site

� ACCESS – Identify a safe approach to site � LOCATION – State the exact location of the

incident � EMERGENCY SERVICES – State those

present and those required. � TYPE – State description of incident. Initial public protection advice – Go in, Stay in, Tune in and read calendar.

2 EMERGENCY

STANDBY STAFF

GROUP PAGE (Site

Specific)

Always set off the pagers, even in normal working hours. Full details on pager instructions, individual pager numbers and other contact details for standby staff are in the Station Emergency Telephone Directory (Site Specific).

3 ADJACENT STATION

(Site Specific)

DIRECT WIRE

or (Site

Specific)

(Site Specific)

4 BARNWOOD

ALERT CENTRE

Always call the Barnwood Alert Centre, they will prompt for the information required.

5 FIRE & RESCUE

SERVICE 999

Confirm they have received notification from the Police.

6 AMBULANCE

SERVICE 999

Confirm they have received notification from the Police.

7 OTHER

(Site Specific) (Site

Specific)

(Site Specific)

Order has changed