2
• Standard Input -18,000-165,000 BTUh / 0.5 - 9.2gpm (NRCR92) 18,000-199,900 BTUh / 0.5 - 11.1gpm (NRCR111) Compact Design - ANSI Z21.10.3/CSA 4.3 certified design that can be wall-mounted indoors or installed outdoors using the optional Vent Cap • Wi fi Capable • Heat Exchanger - manufactured with high quality stainless steel Venting Options - available in Direct Vent model that can use either 2” or 3” Schedule 40 PVC/CPVC , flexible PP vent, or installed outdoors with Vent Cap. • Direct Electronic Ignition • Multi-System Capability - units can be linked together by using the optional 2-unit Quick Connect for twice the hot water capacity Fully Modulating - BTU input range from 18,000 to 330,000/399,800 BTUh (with Quick Connect) with stable combustion provided by gas venturi and pre-mix burner. Each individual unit 9/11:1 Turndown Ratio Energy Factor (UEF) - 0.97 (NG) / 0.97 (LP) T emperature Controls - includes remote thermostat that can precisely adjust the output temperature from 100°F to 140°F • Safety Devices - Flame Sensor, Overheat Prevention Device, l l i f r e v O e t a s n e d n o C , n o i t c e t o r P e z e e r F , e c i v e D n o i t c e t o r P g n i n t h g i L • 15 Year Limited Heat Exchanger Warranty for Residential Use Approvals - CSA, UPC , NSF, Low NOx Approved By SCAQMD (Rule 1146.2) NRCR92DV (GQ-C2660WXQ-FF US) NRCRC111DV (GQ-C3260WXQ-FF US) Residential Condensing Water Heater Specification Sheet NORITZ AMERICA CORPORATION 11160 Grace Avenue, Fountain Valley, CA 92708 Tel. 1-866-7NORITZ www.noritz.com Quick Connect Cord (#QC-2) Wireless Monitor (#NWC-ADAPTER) Outdoor Vent Cap (#VC-6) Isolator Valves (#IK-WV-200) Birdscreen (#VT_-PVCS) SV Co nversion (#SV-CK-2) CERTIFIED R LOW-LEAD PVC Concentric Termination (#PVC-_CT) Accessories 3” Horizontal Hood Termination (#PVT-HL) ) _ - K V F 2 Z E # ( t i K t n e V x e l F P P EZTR Conversion Kit (#EZ2-CK) Uniform • Compatible with 1/2” gas pipe - see installation manual 5 Year Limited Parts Warranty & 1 Year Reasonable Labor Neutralizer for 1-unit (#NC-1S) * Refer to the Noritz Limited Warranty for complete coverage details ** This product complies with California AB 1953 Low Lead Law and section 1417(d) of the Safe Drinking Water Act , at Noritz.com * ** Crossover Valve Kit (#cCS-V) Crossover Valve Kit with Bypass (#CSV-BPK) Universal Concentric Vent Kit (#PVC-UCVK) Low Profile Termination Kit (#PVC-_LPT) Programmable Remote (#RC-9018) • Built-In Recirculation - - Equiped with a built-in pump for whole home recirculation. Automatically adjusts to hot water demand without any set up. Custom time available with optional remote. Compatible with On-Demand Recirculation. • Crossover Compatible - - available crossover valve kit for recirculation applications without need for dedicated return line.

NRCR92DV (GQ-C2660WXQ-FF US) NRCRC111DV (GQ …• 0.97 (NG) / 0.97 (LP)Energy Factor (UEF) - • Temperature Controls - includes remote thermostat that can precisely adjust the output

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: NRCR92DV (GQ-C2660WXQ-FF US) NRCRC111DV (GQ …• 0.97 (NG) / 0.97 (LP)Energy Factor (UEF) - • Temperature Controls - includes remote thermostat that can precisely adjust the output

• Standard Input -18,000-165,000 BTUh / 0.5 - 9.2gpm (NRCR92) 18,000-199,900 BTUh / 0.5 - 11.1gpm (NRCR111)

• Compact Design - ANSI Z21.10.3/CSA 4.3 certified design that can be wall-mounted indoors or installed outdoors using the optional Vent Cap

• Wi fi Capable

• Heat Exchanger - manufactured with high quality stainless steel

• Venting Options - available in Direct Vent model that can use either 2” or 3” Schedule 40 PVC/CPVC , flexible PP vent, or installed outdoors with Vent Cap.

• Direct Electronic Ignition

• Multi-System Capability - units can be linked together by using the optional 2-unit Quick Connect for twice the hot water capacity • Fully Modulating - BTU input range from 18,000 to 330,000/399,800 BTUh (with Quick Connect) with stable combustion provided by gas venturi and pre-mix burner. Each individual unit 9/11:1 Turndown Ratio

• Energy Factor (UEF) - 0.97 (NG) / 0.97 (LP)

• Temperature Controls - includes remote thermostat that can precisely adjust the output temperature from 100°F to 140°F

• Safety Devices - Flame Sensor, Overheat Prevention Device, llifrevO etasnednoC ,noitcetorP ezeerF ,eciveD noitcetorP gninthgiL

• 15 Year Limited Heat Exchanger Warranty for Residential Use

• Approvals - CSA, UPC , NSF, Low NOx Approved By SCAQMD (Rule 1146.2)

NRCR92DV (GQ-C2660WXQ-FF US) NRCRC111DV (GQ-C3260WXQ-FF US)Residential Condensing Water Heater

Specification Sheet

NORITZ AMERICA CORPORATION11160 Grace Avenue, Fountain Valley, CA 92708 Tel. 1-866-7NORITZ www.noritz.com

Quick Connect Cord (#QC-2)

Wireless Monitor (#NWC-ADAPTER)

Outdoor Vent Cap (#VC-6)

Isolator

Valves (#IK-WV-200)

Birdscreen (#VT_-PVCS)

SV Conversion (#SV-CK-2)

CERTIFIEDR

LOW-LEAD

PVC Concentric Termination(#PVC-_CT)

Accessories

3” Horizontal Hood Termination(#PVT-HL)

)_-KVF2ZE#( tiK tneV xelF PP

EZTR Conversion Kit (#EZ2-CK)

Uniform

• Compatible with 1/2” gas pipe - see installation manual

5 Year Limited Parts Warranty & 1 Year Reasonable Labor

Neutralizer for 1-unit (#NC-1S)

*

Refer to the Noritz Limited Warranty for complete coverage details

** This product complies with California AB 1953 Low Lead Law and section 1417(d) of the Safe Drinking Water Act

, at Noritz.com

*

**

Crossover Valve Kit (#cCS-V)

Crossover Valve Kit with Bypass (#CSV-BPK)

Universal Concentric Vent Kit (#PVC-UCVK)Low Profile Termination Kit (#PVC-_LPT)

Programmable Remote (#RC-9018)

• Built-In Recirculation - - Equiped with a built-in pump for whole home recirculation. Automatically adjusts to hot water demand without any set up. Custom time available with optional remote. Compatible with On-Demand Recirculation. • Crossover Compatible - - available crossover valve kit for recirculation applications without need for dedicated return line.

Page 2: NRCR92DV (GQ-C2660WXQ-FF US) NRCRC111DV (GQ …• 0.97 (NG) / 0.97 (LP)Energy Factor (UEF) - • Temperature Controls - includes remote thermostat that can precisely adjust the output

Rev. 3/17

Dimensions

ut notice.

Specifications

30 40 45 50 60 70 80 90 100 110 120 130 140

11.1 9.7 8.7 7.8 6.5 5.5 4.8 4.3 3.9 3.5 3.2 3.0 2.8

TemperatureRise (°F)NRCR111(GPM)

Flow Rates

73 pounds

Water Inlet

Hot Water Outlet

Condensate Drain

Supply

Consumption

Temperature Settings 100-140°F (In 5°F intervals) (9 Options)

Connection Sizes

Weight

Water Holding Capacity

Power

Model Name

Freeze Protection Indoor: -30°F

37-48°C (In 1°C intervals), 50-60°C (In 5°C intervals) (15 Options)°F Mode

°C Mode

Gas Inlet

0.85 Gallon (3.2L)

1/2" NPT

120VAC (60Hz), less than 4 amperes

NG:185W (NRCR92) 218W (NRCR111) LP: 175W (NRCR92) 202W (NRCR111) Freeze Protection: 114W

NRCR92DV / NRCR111DV (GQ-C2660/3260WXQ-FF US)

Outdoor: -4°F

Operating Pressure

Gas Supply Pressure NG: 4.0” - 10.5” LP: 8.0” - 14.0”

15 - 150 psi

9.2 8.0 7.1 6.4 5.3 4.6 4.0 3.6 3.2 2.9 2.7 2.5 2.3NRCR92(GPM)

< inch (mm) >

Rev. 01/2020

Recirculation Return

3/4" NPT

3/4" NPT

3/4" NPT

3/4" NPT

Hot-dipped zinc-aluminum-magnesium-alloy-coated steel w/ Polyester CoatingFront CoverCasing

Materials

2.3”

[58]

2.0”

[52]

3×0.5”×1.6”[12×40]RECTANGLE HOLE

1.6”[40]10.2”[260]

0.5”

[12]

27.1

”[69

0]

27.4

”[69

6]

2.2”[56]3.9”[100]5.2”[132]6.7”[169]8.1”[206]

2×0.4”×0.24”[10×6]OBLONG HOLE

4×0.24”×0.6”[6×15]OBLONG HOLE

4×Φ0.5”[Φ13]

14.1”[359]

1.1”[27]3.5”[89]

0.3”[8]

26.0

”[66

1]

25.9

”[65

8]

2.3”

[59]

0.4”[10]

WALL MOUTING BRACKET(INCLUDED ACCESSORY)7×Φ0.2”[Φ6]

16.0”[406]10.2”[260]

5.1”[130]

7.2”[183]

2.1”[5.3]

HEIGHT OF EACH FITTING FROM BOTTOM OF CASE

HOT WATER OUTLET 1.8”[45]COLD WATER INLET 1.9”[49]

CONDENSATE DRAIN 1.7”[42]HOT WATER RETURN 2.7”[69]

GAS INLET 2.2”[56]

I.DΦ2.4”[Φ61]

AIR INLET

18.5”[471]

17.8”[451]10.1”[256]5.1”[130]

I.DΦ2.4”[Φ61]

FLUE COLLAR

27.0

”[68

7]

17.8”[452]

(VIEW FROM BOTTOM)COLD WATER INLET(3/4”)

WIRING THROUGHWAY

WATER DRAIN VALVE(WATER FILTER)WIRING THROUGHWAY(AC120V)

WATER DRAIN VALVE

HOT WATER OUTLET(3/4”)

GAS INLET(3/4”)

WATER DRAIN VALVE

HOT WATER RETURN(3/4”)

11.3

”[28

8]9.

7”[2

46]

2.0”

[51]

4.9”

[124

]

1.7”[42]

5.7”[144]7.0”[177]9.2”[234]

15.4”[392]15.6”[397]

10.9”[276]

CONDENSATE DRAIN(1/2”)

WATER DRAIN VALVE

2.2”

[56]

6.0”

[152

]8.

3”[2

29]

(VIEW FROM TOP)

(VIEW FROM FRONT)(VIEW FROM SIDE)

Flow Rate (GPM)

Pres

sure

Los

s (F

t. of

hea

d)

Pres

sure

Los

s (p

si)

0

10

20

30

40

50

60

70

80

0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.00

5

10

15

20

25

30

35Bypass Flow Control Valve Close Settemperature : 125 F or higher

Bypass Flow Control Valve Open Set temperature : 120 F or lower

Pressure Drop Pump Performance