2
AS-Interface siemens.com / as-interface AS-Interface – the effective field bus standard on actuator-sensor level – can now be connected to SIMATIC S7-1200 via plug & play. The new AS-i master CM 1243-2 is simply plugged onto the CPU and wired with the field. For the first time based on the same engineering as PROFINET. Your benefit? The design and installation of automation control equipment has never been more easy and efficient. With the TIA Portal engineering framework, AS-Interface networks are configured graphically. The same way as PROFIBUS and PROFINET networks. Intuitive, efficient, tried-and-proven Redefined engineering in TIA Portal. Now Stirring up the Field: SIMATIC S7-1200 AS-i Master The new AS-i master perfectly interacts with SIMATIC S7-1200 and benefits from the Totally Integrated Automation Portal

Now Stirring up the Field: SIMATIC S7-1200 AS-i Master

  • Upload
    ngothu

  • View
    222

  • Download
    1

Embed Size (px)

Citation preview

Page 1: Now Stirring up the Field: SIMATIC S7-1200 AS-i Master

AS-Interface

siemens.com / as-interface

AS-Interface – the effective field bus standard on actuator-sensor level – can now be connected to SIMATIC S7-1200 via plug & play. The new AS-i master CM 1243-2 is simply plugged onto the CPU and wired with the field. For the first time based on the same engineering as PROFINET.

Your benefit? The design and installation of automation control equipment has never been more easy and efficient. With the TIA Portal engineering framework, AS-Interface networks are configured graphically. The same way as PROFIBUS and PROFINET networks. Intuitive, efficient, tried-and-proven

Redefined engineering in TIA Portal.

Now Stirring up the Field: SIMATIC S7-1200 AS-i MasterThe new AS-i master perfectly interacts with SIMATIC S7-1200 and benefits from the Totally Integrated Automation Portal

Page 2: Now Stirring up the Field: SIMATIC S7-1200 AS-i Master

The AS-i master at a glance

•Master acc. to AS-i Specification 3.0

•Up to 62 AS-i slaves or 992 I/Os per master

•Optional access via web interface

• Integrated analog value transmission and AS-i power failure detection

• Support of firmware updates

•Optional DCM 1271 data decoupling module, e.g. for AS-i Power24V

• Parameterization of SIRIUS M200D AS-i motor starters (motor currents, limit values, class times, etc.) without additional function blocks in the control

Order numbers

•AS-i master 3RK7 243-2AA30-0XB0

•Data decoupling module 3RK7 271-1AA30-0AA0

AS-i master – the new standard

The new AS-i master CM 1243-2 communication module of SIMATIC S7-1200 now connects the lowest field level to the process and control level – ensuring simple and accelerated configuration and commissioning. This is supported by the AS-i master’s perfect interaction with the CPU of SIMATIC S7-1200.

A further reason for opting to the tried-and-tested actuator-sensor bus by Siemens – thereby benefiting from a full-range product portfolio, compre-hensive know-how and global support from a single source.

As a special highlight, no additional software is now required for getting started or converting thanks to the TIA Portal – AS-i engineering is just as comfortable and efficient as with PROFIBUS or PROFINET.

More than just I/O processing

The AS-i master CM 1243-2 represents the core of your actuator-sensor bus and comprises more functions than mere sensor detection or actuator control in the field: For example parameterization of our AS-i motor starters without additional function blocks or optional access via web interface – all integrated additional functions exceed the standard by far.

Comfortable engineering in TIA Portal

The TIA Portal represents the intuitive, efficient and proven engineering framework for control programming, parameterization, diagnostics and remote maintenance – also of fail-safe applications and complex automation tasks.

For example, the entire layout of a connected AS-i network can be loaded into the TIA Portal via a mouse-click, where the slaves’ parameters can be adjusted within the represented network topology. Also diagnostics and troubleshooting are considerably eased through online representation within the network view.

Siemens Industry, Inc.5300 Triangle ParkwayNorcross, GA 30092

[email protected]

Subject to change without prior notice Order No. CPBR-ASIS7-0212Printed in USAAll rights reserved © 2012 Siemens Industry, Inc.

The information contained in this brochure merely com- prises general descriptions or performance characteristics, which may not always be applicable in the described form to the specific application case or which may change due to product advancement. The desired performance charac-teristics shall only be binding if they are expressly specified upon contract conclusion. All product designations may be trademarks or product names of Siemens AG or supplier companies whose utili- zation by third parties for their own purposes may violate the rights of the owners.

In the TIA Portal, AS-i networks are configured in the same manner already known from PROFIBUS or PROFINET: Simply via drag & drop

The AS-i master is simply plugged onto the CPU of SIMATIC S7-1200. The optionally available DCM 1271 data decoupling module supports utilization of AS-i Power24V.

SIMATIC S7-1200 with the connected bus systems PROFIBUS, AS-Interface and PROFINET by Siemens

PROFINET / Industrial Ethernet

AS-Interface

SIMATIC S7-1200 with CM 1243-2

Signaling columns

Pushbuttons Indicator lights

Load feeders 3RA2

Compact- starter 3RA6

Motor starter M200D

Power supply unitAS-Interface

Power supply unit24 V DC

Further information:www.siemens.com / as-interface