Novel use of the Solitaire© AB re-deployable stent for exclusion of wide neck peri-hilar Renal Artery Aneurysms (RAAs) Khawaja AZ 1 , Inston NG 1 , Lipkin G 2 , Jones RG 3

Novel use of the Solitaire AB re-deployable stent for exclusion ......• 6mm by 3 cm Solitaire© AB* positioned/repositioned * Covidien, eV3 Intl, Herts, UK Technique • Embolization

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Novel use of the Solitaire AB re-deployable stent for exclusion ......• 6mm by 3 cm Solitaire© AB* positioned/repositioned * Covidien, eV3 Intl, Herts, UK Technique • Embolization

Novel use of the Solitaire© AB re-deployable stent for exclusion of wide

neck peri-hilar Renal Artery Aneurysms (RAAs)

Khawaja AZ1, Inston NG1, Lipkin G2, Jones RG3

Page 2: Novel use of the Solitaire AB re-deployable stent for exclusion ......• 6mm by 3 cm Solitaire© AB* positioned/repositioned * Covidien, eV3 Intl, Herts, UK Technique • Embolization

Disclosure

Speaker name: Aurang Zaib Khawaja

.................................................................................

I do not have any potential conflict of interest x

Page 3: Novel use of the Solitaire AB re-deployable stent for exclusion ......• 6mm by 3 cm Solitaire© AB* positioned/repositioned * Covidien, eV3 Intl, Herts, UK Technique • Embolization

Background •  Low incidence, ~70% asymptomatic, incidental finding

•  Indications for repair: limited evidence, interpretable

•  Common ethiology: FMD, ATS, Vasculitis, Trauma

•  Treatment strategies: Surgical in-vivo/ex-vivo, embolisation, stents, endografts, combination therapy

•  Complex cases: risk of parenchymal infarction, nephrectomy

Page 4: Novel use of the Solitaire AB re-deployable stent for exclusion ......• 6mm by 3 cm Solitaire© AB* positioned/repositioned * Covidien, eV3 Intl, Herts, UK Technique • Embolization

Case 1 •  55 yr old hypertensive female

•  Incidental finding

•  2.5 cm wide neck saccular Right RAA

•  Multidisciplinary review, informed consent

•  7 French Destination©* renal double curve shaped sheath *Terumo Interventional Systems, Surrey, UK

Page 5: Novel use of the Solitaire AB re-deployable stent for exclusion ......• 6mm by 3 cm Solitaire© AB* positioned/repositioned * Covidien, eV3 Intl, Herts, UK Technique • Embolization

Technique •  Separate micro catheter placed in

main body

•  Selective catheterization of upper pole branch

•  6mm by 3 cm Solitaire© AB* positioned/repositioned

* Covidien, eV3 Intl, Herts, UK

Page 6: Novel use of the Solitaire AB re-deployable stent for exclusion ......• 6mm by 3 cm Solitaire© AB* positioned/repositioned * Covidien, eV3 Intl, Herts, UK Technique • Embolization

Technique •  Embolization coils deployed via

selective micro catheter

•  Stent then detached in a satisfactory position

•  Completion angiography: •  successful exclusion •  preservation of both arteries

Page 7: Novel use of the Solitaire AB re-deployable stent for exclusion ......• 6mm by 3 cm Solitaire© AB* positioned/repositioned * Covidien, eV3 Intl, Herts, UK Technique • Embolization

Post Procedure •  No major or minor complications

•  Dual antiplatelet for 6 weeks - life-long aspirin

•  3 months post procedure : 2 antihypertensives stopped & eGFR 74

•  Follow up MRA at 60 days •  patent renal vessels •  minor proximal filling but vast majority of

aneurysm excluded

Page 8: Novel use of the Solitaire AB re-deployable stent for exclusion ......• 6mm by 3 cm Solitaire© AB* positioned/repositioned * Covidien, eV3 Intl, Herts, UK Technique • Embolization

Case 2 •  55 yr old female - FMD

•  Incidental finding

•  Multidisciplinary review

•  2 cm dumbbell shaped aneurysm at bifurcation of main renal

Page 9: Novel use of the Solitaire AB re-deployable stent for exclusion ......• 6mm by 3 cm Solitaire© AB* positioned/repositioned * Covidien, eV3 Intl, Herts, UK Technique • Embolization

Technique •  A 6Fr Chariot© shapeable

sheath

•  6mm by 3 cm Solitaire© AB* positioned/repositioned & deployed

•  Aneurysm catheterised via same access sheath

* Boston Scientific, Herts, UK

Page 10: Novel use of the Solitaire AB re-deployable stent for exclusion ......• 6mm by 3 cm Solitaire© AB* positioned/repositioned * Covidien, eV3 Intl, Herts, UK Technique • Embolization

Technique •  Multiple detachable embolization coils

deployed via selective micro catheter

•  Stent detached in a satisfactory position

Page 11: Novel use of the Solitaire AB re-deployable stent for exclusion ......• 6mm by 3 cm Solitaire© AB* positioned/repositioned * Covidien, eV3 Intl, Herts, UK Technique • Embolization

Post Procedure •  Completion angiography:

•  successful exclusion •  preservation of both upper & lower pole

arteries

•  No other major or minor procedure related complications

•  Follow up at 60 days normotensive and eGFR 79

Page 12: Novel use of the Solitaire AB re-deployable stent for exclusion ......• 6mm by 3 cm Solitaire© AB* positioned/repositioned * Covidien, eV3 Intl, Herts, UK Technique • Embolization

Discussion •  Elective open & endovascular repair reported equivalent

•  Surgical opinion - complex, higher risk

•  Endovascular opinion - incomplete exclusion, parenchymal loss

•  Indication for repair - symptomatic, patient preference

Page 13: Novel use of the Solitaire AB re-deployable stent for exclusion ......• 6mm by 3 cm Solitaire© AB* positioned/repositioned * Covidien, eV3 Intl, Herts, UK Technique • Embolization

Conclusion •  Solitaire© AB stent – novel use in management of RAA

•  Adequate positioning/repositioning

•  Optimal radial force for flexibility in tortuous anatomy & coil mass support

•  Multidisciplinary approach for complex cases

•  Safe & efficacious in combined management of wide-neck RAAs