16
Introducing the NOVA e-Series Automated Surface Area and Pore Size Analyzer

NOVAe 20series Cecoltec

Embed Size (px)

Citation preview

Page 1: NOVAe 20series Cecoltec

Introducing the NOVA e-Series

Automated Surface Area and Pore Size Analyzer

Page 2: NOVAe 20series Cecoltec

Overview

BET Surface Area

Pore Volume and Pore Size Distribution

Micropore Volume and Area by t Method

CO2 and H2 Adsorption Studies

Page 3: NOVAe 20series Cecoltec

Applications

Nano Materials

Ceramics

Catalyst

Pharmceuticals

Carbons

Minerals

Page 4: NOVAe 20series Cecoltec

Features

Available with 1, 2, 3 or 4 analysis stations

Built In Outgassing Stations

PC or Stand Alone Operation

Multiple Sample Cell Geometries

RTD Level Control System for Ultimate Sensitivity.

Page 5: NOVAe 20series Cecoltec

Features

Patented TempCompTM

Coolant Level Compensation

MaxiDoseTM Dosing Method

NovaWin Software With State-Of-The Art Data Analysis Models

Available 21 CFR 11 Compliant Windows Based Software

Page 6: NOVAe 20series Cecoltec

NOVA e-Series Performance

Three BET Surface Area Measurements In Less Than 30 Minutes

Performs High Resolution Adsorption and Desorption Isotherms

Multiple P0 Measurement Options

May Employ Either Classical Helium or Patented “No Void Analysis” (NOVA) Void Volume Determination techniques.

Patented NOVA technique Enhances Instrument Sensitivity

Page 7: NOVAe 20series Cecoltec

NOVA e-Series Performance

Available with 21 CFR 11 Compliant Software For Pharmaceutical Applications

Available with Any Gas Capability – N2, Ar, CO2 and Other Non Corrosive Gases

Available with Windows Based NovaWin™ Software For Operation and Data Reduction (most complete Data Reduction package available).

Page 8: NOVAe 20series Cecoltec

NOVA e-Series Specifications

Transducer Accuracy: 0.11 % full scale (1000 torr)

Minimum P/P0: 1 x 10-3

with Nitrogen

Surface Area Range: 0.01 m2/g with N2 (no upper limit)

Pore Volume: Detectable limit less than 0.0001 cc/g

Pore Size: Diameter Range 0.35 – 250 nm

Adsorbates: N2, Ar, CO2, and non corrosive gases

Page 9: NOVAe 20series Cecoltec

NovaWin™ Software

Windows™ Based

Instrument Control

Data Reduction

Network Compatible

Windows 2000, XP, and Windows 7

Graphical and Tabular Reports

Site Licensed

Available 21 CFR 11 Compliant

Page 10: NOVAe 20series Cecoltec

NovaWin™ Software

Graphical DisplaysBET and Lanqmuir BJH Pore Size Distribution Dollimore-Heal Pore Size DistributionDubinin-Radushkevich Plotst-Plot (Statistical Thickness)Density Functional Theory (DFT) PlotsMonte Carlo (GCMC) PlotsMP PlotsHK Plots (Horvath-Kawazoe)DA Plots (Dubinia-Astakhov)SF Plots (Saito-Foley)Fractal Dimensions NK and FHH

Page 11: NOVAe 20series Cecoltec

NovaWin™ Software

Tabular DisplaysBET and Lanqmuir

BJH Pore Size Distribution

Dollimore-Heal Pore Size Distribution

Dubinin-Radushkevich

t-Plot (Statistical Thickness)

Density Functional Theory (DFT)

Monte Carlo (GCMC)

MP

HK (Horvath-Kawazoe)

DA (Dubinia-Astakhov)

SF (Saito-Foley)

Fractal Dimensions NK and FHH

Page 12: NOVAe 20series Cecoltec

Additional Sample Preparation

MasterPrep DegasserSix Independent Sample Preparation Stations

Flow or Vacuum Sample Preparation

Six-channel Digital Temperature Controller For Independent Temperature Programming.

Flow and Evacuation Rates Operator Selectable

Temperature Range (35 - 450°C)

Multiple Temperature Ramps Rates and Soak Times

Windows® Based Communication Software

Page 13: NOVAe 20series Cecoltec

Additional Sample Preparation

Autosorb DegasserSix Independent Sample Preparation Stations

Vacuum Sample Preparation

Individual Digital Heat Settings and Temperature Metering

Digital Timer For Precise Preparation Times

Optional Turbomolecular Vacuum System For High Vacuum Sample Preparation

Temperature Range (35 - 400°C)

Page 14: NOVAe 20series Cecoltec

Additional Sample Preparation

FloVac DegasserSix Sample Preparation Stations

Vacuum or Flow Sample Preparation

Individual Control Valves

Vacuum Gauge For Monitoring Outgassing Rate.

Temperature Range (35 - 400°C)

Temperature Ramp Rate (1°C/Min)

Page 15: NOVAe 20series Cecoltec

Additional Sample Preparation

Flow DegasserSix Sample Preparation Stations

Flow Sample Preparation

Individual Control Valves

Temperature Range (35 - 400°C)

Temperature Ramp Rate (1°C/Min)

Page 16: NOVAe 20series Cecoltec

CORPORATE HEADQUARTERSQuantachrome Corporation

1900 Corporate Drive

Boynton Beach, FL 33426 U.S.A.

Phone: (561) 731-4999

Fax: (561) 732-9888

E-mail: [email protected]

EUROPEQuantachrome Limited

European Technical Center

Pale Lane Farm, Pale Lane

Hartley Wintney, Hook RG27 8BA, UK

Phone: 01252 819719

Fax: 01252 819901

Quantachrome GmbH

Rudolf-Diesel Str. 12

85235 Odelzhausen, Germany

Phone: 08 134/93240

Fax: 08 134/932425

Quantachrome Instrument

www.Quantachrome.com

EXIT