NOTES This drawing shall be read in conjunction with all other drawings and specifications for the project. Any discrepancies shall be referred to the architect for clarification before proceeding with work. All dimensions shall be verified on site prior to commencement of construction or fabrication on and off site. Figured dimensions to be used rather than scaling. All building work must be carried out in accordance with the Building Code of Australia, all relevant Australian Standards, Council Consent and specialist consultants reports. DRAWING TITLE SITE / ROOF PLAN PROJECT REVISION IANSERCOMBE•ARCHITECT PO BOX 137 PACIFIC PALMS NSW 2428 0425 233 331 [email protected] Ian Sercombe Architect P/L - arb 7089 abn:68 077 364 866 CAD Ref: 19595PetResort-V22.pln PET RESORT DEVELOPMENT APPLICATION PET RESORT 96 COOMBA ROAD CHARLOTTE BAY NSW 2428 LOT:33of120 DP:848596 LYN + TRENT PARMENTER 96 COOMBA ROAD CHARLOTTE BAY NSW 2428 CLIENT LEGEND . A2.1 DRAWING NO. 19595 SCALE@A3 PROJECT NO. 1:500 DRAWING ISSUE 26/2/20 DRAWN BY: SH DEVELOPMENT APPLICATION 26 FEB 2020 . . . . 100.0 131.525 91.46 33 1.827 ha 78.32 PEG PEG KE LINE PEG (80.525) 5,513 4,933 6,193 58,003 ALL ROOF WATER TO 100kL RAINWATER TANK. REFER STORMWATER MANAGMENT PLAN FOR ADDITIONAL DETAILS APPROXIMATE RAINGARDEN LOCATION REFER STORMWATER CONSULTANTS REPORT DIVERSION TRENCH OR LEVEL SPREADER TO STORMWATER MANAGMENT PLAN DETAILS PROPOSED EFFLUENT DISPOSAL AREA CARPARK DRIVEWAY SITE BOUNDARY SITE BOUNDARY SITE BOUNDARY SITE BOUNDARY EXISTING TRACK EXISTING ACCESS ROAD WATER FEATURE 21,890 10,000 16,030 OUTDOOR PLAY EXISTING RESIDENCE 37 38 36 35 34 33 32 PET RESORT EXISTING STUDIO NOTIFICATION PLAN

NOTIFICATION PLAN EY E Y - midcoast.nsw.gov.au · scale@a3 project no. 1:500 drawing issue drawn by: sh 26/2/20 development application 26 feb 2020. .. . 100.0 131.525 91.46 1.827

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: NOTIFICATION PLAN EY E Y - midcoast.nsw.gov.au · scale@a3 project no. 1:500 drawing issue drawn by: sh 26/2/20 development application 26 feb 2020. .. . 100.0 131.525 91.46 1.827

NOTESThis drawing shall be read in conjunction with all otherdrawings and specifications for the project.Any discrepancies shall be referred to the architect forclarification before proceeding with work.All dimensions shall be verified on site prior tocommencement of construction or fabrication on andoff site.Figured dimensions to be used rather than scaling.All building work must be carried out in accordancewith the Building Code of Australia, all relevantAustralian Standards, Council Consent and specialistconsultants reports.

DRAWING TITLE

SITE / ROOF PLANPROJECT

REVISION

IANSERCOMBE•ARCHITECTPO BOX 137 PACIFIC PALMS NSW 24280425 233 [email protected]

Ian Sercombe Architect P/L - arb 7089 abn:68 077 364 866CAD Ref: 19595PetResort-V22.pln

PET RESORTDEVELOPMENT APPLICATION

PET RESORT96 COOMBA ROADCHARLOTTE BAY NSW 2428LOT:33of120 DP:848596

LYN + TRENT PARMENTER96 COOMBA ROADCHARLOTTE BAY NSW 2428

CLIENT

LEGEND

. A2.1DRAWING NO.

19595SCALE@A3 PROJECT NO.

1:500DRAWING ISSUE

26/2/20DRAWN BY: SH

DEVELOPMENT APPLICATION 26 FEB 2020. .. .

100.0

131.525

91.

46

331.827 ha

78.32

PEG

PEG

STAK

E

LIN

E PE

G

(80.525)

5,513

4,933

6,193

58,003

ALL ROOF WATER TO 100kLRAINWATER TANK.REFER STORMWATERMANAGMENT PLAN FORADDITIONAL DETAILS

APPROXIMATE RAINGARDEN LOCATIONREFER STORMWATER CONSULTANTS REPORT

DIVERSION TRENCH OR LEVEL SPREADER TOSTORMWATER MANAGMENT PLAN DETAILS

PROPOSED EFFLUENTDISPOSAL AREA

CARPARK

DRIVEWAY

SITE

BO

UND

ARY

SITE BOUNDARY

SITE BOUNDARY

SITE BOUNDARY

EXISTING TRACK

EXIS

TING

AC

CES

S RO

AD

WATERFEATURE

21,890

10,000

16,030

OUTDOORPLAY

EXISTINGRESIDENCE

37

38

36

35

34

33

32

PET RESORTEXISTINGSTUDIO

NOTIFICATION PLAN

Page 2: NOTIFICATION PLAN EY E Y - midcoast.nsw.gov.au · scale@a3 project no. 1:500 drawing issue drawn by: sh 26/2/20 development application 26 feb 2020. .. . 100.0 131.525 91.46 1.827

NOTESThis drawing shall be read in conjunction with all otherdrawings and specifications for the project.Any discrepancies shall be referred to the architect forclarification before proceeding with work.All dimensions shall be verified on site prior tocommencement of construction or fabrication on andoff site.Figured dimensions to be used rather than scaling.All building work must be carried out in accordancewith the Building Code of Australia, all relevantAustralian Standards, Council Consent and specialistconsultants reports.

DRAWING TITLE

ELEVATIONSPROJECT

REVISION

IANSERCOMBE•ARCHITECTPO BOX 137 PACIFIC PALMS NSW 24280425 233 [email protected]

Ian Sercombe Architect P/L - arb 7089 abn:68 077 364 866CAD Ref: 19595PetResort-V22.pln

PET RESORTDEVELOPMENT APPLICATION

PET RESORT96 COOMBA ROADCHARLOTTE BAY NSW 2428LOT:33of120 DP:848596

LYN + TRENT PARMENTER96 COOMBA ROADCHARLOTTE BAY NSW 2428

CLIENT

LEGEND

. A3.1DRAWING NO.

19595SCALE@A3 PROJECT NO.

1:100DRAWING ISSUE

26/2/20DRAWN BY: SH

0 1 2 5m

820P DOOR LEAF/HANDLE TYPE101D GLAZED DOOR No. TAG101W GLAZEDWINDOW No. TAG

FFL FINISHED FLOOR LEVELRL REDUCED LEVELSFL STRUCTURAL FLOOR LEVEL

CLDWFFPFWGASGBHT:M

CLOTHES LINEDISHWASHERFREEZERFIREPLACEFLOOR WASTEGAS CYLINDERGAS BAYONETHOSE TAP MAINS

HT:THWINRRWPWT

HOSE TAP TANKGAS INSTANTANEOUSINVERTERBAR FRIDGEREFRIGERATORWATER PUMPWATERTANK

DEVELOPMENT APPLICATION 26 FEB 2020. .. .

+50,000

+54,450

600 600

COLORBOND GUTTERS& DOWNPIPES

INSULATED PANEL ROOF

FIXED DOUBLE GLAZED WINDOWS

140x140HARDWOOD POSTS

HEBEL POWERWALL SELECTED GLAZING100kL RAINWATER TANK

FFL GROUND FLOOR

TOP OF ROOF

+50,000

+54,450

FIXED DOUBLE GLAZING

HEBEL POWERWALL

INSULATED PANEL ROOF

140x140HARDWOOD POSTS

FFL GROUND FLOOR

TOP OF ROOF

BUSHFIRE NOTES:- ALL MATERIALS & CONSTRUCTION OF WORKS ARE TO COMPLY WITH THE BAL LEVELS AS NOTED IN THE BUSHFIRE ASSESSMENT- CONSTRUCTION IS TO COMPLY WITH AS3959

1-

NORTH ELEVATION1:100

2-

SOUTH ELEVATION1:100

NOTIFICATION PLAN

Page 3: NOTIFICATION PLAN EY E Y - midcoast.nsw.gov.au · scale@a3 project no. 1:500 drawing issue drawn by: sh 26/2/20 development application 26 feb 2020. .. . 100.0 131.525 91.46 1.827

NOTESThis drawing shall be read in conjunction with all otherdrawings and specifications for the project.Any discrepancies shall be referred to the architect forclarification before proceeding with work.All dimensions shall be verified on site prior tocommencement of construction or fabrication on andoff site.Figured dimensions to be used rather than scaling.All building work must be carried out in accordancewith the Building Code of Australia, all relevantAustralian Standards, Council Consent and specialistconsultants reports.

DRAWING TITLE

ELEVATIONSPROJECT

REVISION

IANSERCOMBE•ARCHITECTPO BOX 137 PACIFIC PALMS NSW 24280425 233 [email protected]

Ian Sercombe Architect P/L - arb 7089 abn:68 077 364 866CAD Ref: 19595PetResort-V22.pln

PET RESORTDEVELOPMENT APPLICATION

PET RESORT96 COOMBA ROADCHARLOTTE BAY NSW 2428LOT:33of120 DP:848596

LYN + TRENT PARMENTER96 COOMBA ROADCHARLOTTE BAY NSW 2428

CLIENT

LEGEND

. A3.2DRAWING NO.

19595SCALE@A3 PROJECT NO.

1:100DRAWING ISSUE

26/2/20DRAWN BY: SH

0 1 2 5m

820P DOOR LEAF/HANDLE TYPE101D GLAZED DOOR No. TAG101W GLAZEDWINDOW No. TAG

FFL FINISHED FLOOR LEVELRL REDUCED LEVELSFL STRUCTURAL FLOOR LEVEL

CLDWFFPFWGASGBHT:M

CLOTHES LINEDISHWASHERFREEZERFIREPLACEFLOOR WASTEGAS CYLINDERGAS BAYONETHOSE TAP MAINS

HT:THWINRRWPWT

HOSE TAP TANKGAS INSTANTANEOUSINVERTERBAR FRIDGEREFRIGERATORWATER PUMPWATERTANK

DEVELOPMENT APPLICATION 26 FEB 2020. .. .

+50,000

+54,450

INSULATED PANEL ROOF

COLORBOND GUTTERS & DOWNPIPES

HEBEL POWERWALLFIXED DOUBLE GLAZED WINDOWS

FENCE100kL RAINWATER TANK

FFL GROUND FLOOR

TOP OF ROOF

5

+50,000

+54,450

1,200

900

SELECTED GLAZING

INSULATED PANEL ROOF

COLORBOND GUTTERS& DOWNPIPES HEBEL POWERWALL

AWNING ROOF

FENCERAINWATER TANKS

FFL GROUND FLOOR

TOP OF ROOF

BUSHFIRE NOTES:- ALL MATERIALS & CONSTRUCTION OF WORKS ARE TO COMPLY WITH THE BAL LEVELS AS NOTED IN THE BUSHFIRE ASSESSMENT- CONSTRUCTION IS TO COMPLY WITH AS3959

1-

EAST ELEVATION1:100

2-

WEST ELEVATION1:100

NOTIFICATION PLAN