7
Notes . This drawing is to be read in conjunction with other drawings of the set. . No variation is to be made to this drawing without the prior approval of the Principal and/or Superintendent. . This drawing is not to be scaled. . Contractor to verify all dimensions before commencing work. . Ground levels indicated are approximate only and must be confirmed on site prior to commencement. . All materials constructions etc. are to comply with all relevant codes, by laws, Building Code of Australia, etc. . Foundations, excavations, reinforcement placement etc. to be inspected and approved by the building surveyor prior to any concrete placement. . New concrete work is to comply with the requirements of SAA code AS 3600 - 2001 and subsequent amendments - as applicable. . Structural framing to be in accordance with AS 1684 Timber Framing Code. Structural Hardwood to have min stress grading of F8 and Radiata Pine of F5 by approved test method. . Stormwater to be connected to existing system to approval. . All glazing to be in accordance with AS 1288 and AS2047. . All waterproofing to be in accordance with AS3740. . Smoke detectors (to comply with AS 3786) are to be installed in accordance with Building Code of Australia requirements. . Soil classification: refer soil test report. 37 (lot 36) tussock drive peppercress street priest street 37 Tussock Drive, White Hills Morton Dunn Pty. Ltd. ACN 006 923 057 Copyright Reserved V:\MIND Housing\Lot 36 Tussock Dr, Whitehills\Tussock WDA01 - 25 May 18.dwg FILE NAME: Rev: Amendment: Date: Drawn: sheet title project status job no. scale @ A1 drawn checked approved type Cover Sheet & Locality Plan date 1:1000 drawing no. 00 revision - Ballarat: 424 Sturt Street (PO Box 772) Ballarat VIC 3350 Phone: 03 5331 5977 Fax: 03 5332 6599 Email: [email protected] ARCHITECTS morton dunn Geelong: 149 Pakington Street Geelong West VIC 3218 Phone: 03 5221 7885 Fax: 03 5221 7885 www.mortondunn.com.au MIND Australia 37 Tussock Drive White Hills Supported Accommodation Residence PRELIMINARY - 25 MAY 2018 ML WDA - - EXISTING AND PROPOSED SITE PLAN COVER SHEET WDA 01 WDA 00 WDA 02 PROPOSED FLOOR PLAN & ROOF PLAN WDA 03 DETAILS WDA 04 WDA 05 WDA 06 locality plan scale 1:1000 (A1) PROPOSED ELEVATIONS & SECTIONS INTERNAL ELEVATIONS 1 N INTERNAL ELEVATIONS 2

Notes - Disability Housing

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Notes - Disability Housing

Notes. This drawing is to be read in conjunction with other drawingsof the set.. No variation is to be made to this drawing without the priorapproval of the Principal and/or Superintendent.. This drawing is not to be scaled.. Contractor to verify all dimensions before commencingwork.. Ground levels indicated are approximate only and must beconfirmed on site prior to commencement.. All materials constructions etc. are to comply with allrelevant codes, by laws, Building Code of Australia, etc.. Foundations, excavations, reinforcement placement etc. tobe inspected and approved by the building surveyor prior toany concrete placement.. New concrete work is to comply with the requirements ofSAA code AS 3600 - 2001 and subsequent amendments - asapplicable.. Structural framing to be in accordance with AS 1684 TimberFraming Code. Structural Hardwood to have min stressgrading of F8 and Radiata Pine of F5 by approved testmethod.. Stormwater to be connected to existing system to approval.. All glazing to be in accordance with AS 1288 and AS2047.. All waterproofing to be in accordance with AS3740.. Smoke detectors (to comply with AS 3786) are to be installedin accordance with Building Code of Australia requirements.. Soil classification: refer soil test report.

37(lot 36)

t u s s o c k d r i v e

pe

pp

er c

r es s

st r

ee

t

pr i

es t

st r

ee

t

37 Tussock Drive, White HillsMorton Dunn Pty. Ltd. ACN 006 923 057 Copyright Reserved

V:\M

IND

Hou

sing

\Lot

36

Tuss

ock

Dr,

Whi

tehi

lls\T

usso

ck W

DA0

1 - 2

5 M

ay 1

8.dw

gFI

LE N

AM

E:

Rev: Amendment: Date: Drawn:

sheet title

project status

job no.

scale @ A1 drawn checked approved

type

Cover Sheet & Locality Plan

date

1:1000

drawing no.

00revision

-

Ballarat:424 Sturt Street (PO Box 772)Ballarat VIC 3350Phone: 03 5331 5977Fax: 03 5332 6599

Email: [email protected]

ARCHITECTSmorton dunn

Geelong:149 Pakington Street

Geelong West VIC 3218Phone: 03 5221 7885

Fax: 03 5221 7885

www.mortondunn.com.au

MIND Australia37 Tussock DriveWhite Hills

SupportedAccommodationResidence

PRELIMINARY

- 25 MAY 2018

ML

WDA

- -

EXISTING AND PROPOSED SITE PLANCOVER SHEET

WDA 01WDA 00

WDA 02 PROPOSED FLOOR PLAN & ROOF PLANWDA 03

DETAILS

WDA 04WDA 05WDA 06

locality planscale 1:1000 (A1)

PROPOSED ELEVATIONS & SECTIONSINTERNAL ELEVATIONS 1

N

INTERNAL ELEVATIONS 2

Page 2: Notes - Disability Housing

Notes. This drawing is to be read in conjunction with other drawingsof the set.. No variation is to be made to this drawing without the priorapproval of the Principal and/or Superintendent.. This drawing is not to be scaled.. Contractor to verify all dimensions before commencingwork.. Ground levels indicated are approximate only and must beconfirmed on site prior to commencement.. All materials constructions etc. are to comply with allrelevant codes, by laws, Building Code of Australia, etc.. Foundations, excavations, reinforcement placement etc. tobe inspected and approved by the building surveyor prior toany concrete placement.. New concrete work is to comply with the requirements ofSAA code AS 3600 - 2001 and subsequent amendments - asapplicable.. Structural framing to be in accordance with AS 1684 TimberFraming Code. Structural Hardwood to have min stressgrading of F8 and Radiata Pine of F5 by approved testmethod.. Stormwater to be connected to existing system to approval.. All glazing to be in accordance with AS 1288 and AS2047.. All waterproofing to be in accordance with AS3740.. Smoke detectors (to comply with AS 3786) are to be installedin accordance with Building Code of Australia requirements.. Soil classification: refer soil test report.

no. 37

no. 36

no. 38

tussock drive

REMOVE EXISTINGKERBING AND FOOTPATH FOR NEWCROSSOVER TOCOUNCILSREQUIREMENTS

ALLOW TORELOCATE EXISTINGTREE TO COUNCILSREQUIREMENTS

NEW RESIDENCEOUTLINE SHOWNDASHED

kitchen

livingcommon

area

bed 1

bed 2 bed 4

bed 3

staff area a.wca.bath 1

a.bath 2

l'dry

ens.

carport

no. 37

no. 36

no. 38

tussock drive

PL.194

.650

PL.194

.600

PL.194

.600

PL.194

.500

PL.194

.600

PL.194

.550

PL.194

.600

PL.194

.550

PL.194

.450

PL.194

.450

PL.194

.350

PL.194

.550

PL.194

.450

PL.194

.350

PL.194

.550

PL.194

.450

PL.194

.350

PL.194

.250

PL.194

.450

PL.194

.600

PL.194

.500

PL.194

.600

PL.194

.550

PL.194

.500

PL.194

.500

PL.194

.400

PL.194

.300

PL.194

.600

PL.194

.550

PL.194

.450

NEW CROSSOVERTO COUNCILSREQUIREMENTS

ALLOW TORELOCATE EXISTINGTREE TO COUNCILSREQUIREMENTS

Legend

NOTE: PROVIDE 75X25mm TREATED PINEEDGING SCREWED TO HARDWOOD STAKESBETWEEN MULCHED GARDEN BEDS ANDSYNTHETIC GRASS AND LILYDALE TOPPINGS.

Landscaping Legend

NOTE: ALL GATES TO BE 1000mm WIDE

proposed site planscale 1:100 (A1)

N

Morton Dunn Pty. Ltd. ACN 006 923 057 Copyright Reserved

Rev: Amendment: Date: Drawn:

sheet title

project status

job no.

scale @ A1 drawn checked approved

type

Existing & Proposed Site Plan

date

1:100

drawing no.

01revision

-

V:\M

IND

Hou

sing

\Lot

36

Tuss

ock

Dr,

Whi

tehi

lls\T

usso

ck W

DA0

1 - 2

5 M

ay 1

8.dw

gFI

LE N

AM

E:

Ballarat:424 Sturt Street (PO Box 772)Ballarat VIC 3350Phone: 03 5331 5977Fax: 03 5332 6599

Email: [email protected]

ARCHITECTSmorton dunn

Geelong:149 Pakington Street

Geelong West VIC 3218Phone: 03 5221 7885

Fax: 03 5221 7885

www.mortondunn.com.au

MIND Australia37 Tussock DriveWhite Hills

SupportedAccommodationResidence

PRELIMINARY

- 25 MAY 2018

ML

WDA

- -

existing site planscale 1:100 (A1)

N

NOTES:. REFER ALSO TO ELECTRICAL SITE PLAN. ALL LIGHTING BOLLARDS TO RUN OF SW 1. REFER ALSO TO HYDRAULIC SITE PLAN

Page 3: Notes - Disability Housing

Notes. This drawing is to be read in conjunction with other drawingsof the set.. No variation is to be made to this drawing without the priorapproval of the Principal and/or Superintendent.. This drawing is not to be scaled.. Contractor to verify all dimensions before commencingwork.. Ground levels indicated are approximate only and must beconfirmed on site prior to commencement.. All materials constructions etc. are to comply with allrelevant codes, by laws, Building Code of Australia, etc.. Foundations, excavations, reinforcement placement etc. tobe inspected and approved by the building surveyor prior toany concrete placement.. New concrete work is to comply with the requirements ofSAA code AS 3600 - 2001 and subsequent amendments - asapplicable.. Structural framing to be in accordance with AS 1684 TimberFraming Code. Structural Hardwood to have min stressgrading of F8 and Radiata Pine of F5 by approved testmethod.. Stormwater to be connected to existing system to approval.. All glazing to be in accordance with AS 1288 and AS2047.. All waterproofing to be in accordance with AS3740.. Smoke detectors (to comply with AS 3786) are to be installedin accordance with Building Code of Australia requirements.. Soil classification: refer soil test report.

kitchen

livingcommon

area

bed 1

bed 2 bed 4

bed 3

staff area a.wca.bath 1

a.bath 2

l'dry

ens.

carport

COLORBOND 'CUSTOM-ORB'ROOF SHEETING AT 5° PITCH

COLORBOND FASCIA &QUAD GUTTER

FLASH WALL/ROOFJUNCTION TO APPROVAL

COLORBOND 'CUSTOM-ORB'ROOF SHEETING AT 5° PITCH

COLORBOND FASCIA &QUAD GUTTER

STEEL FRAMED PERGOLA(PAINT FINISH)

COLORBONDBARGEBOARD

COLORBONDBARGEBOARD

COLORBONDBARGEBOARD

COLORBONDBARGEBOARD

FLASH PARAPETWALL

COLORBOND 'TRIMDEK' ROOFSHEETING AT 5° PITCH

Legend

proposed roof planscale 1:100 (A1)

N

Morton Dunn Pty. Ltd. ACN 006 923 057 Copyright Reserved

Rev: Amendment: Date: Drawn:

sheet title

project status

job no.

scale @ A1 drawn checked approved

type

Proposed Floor Plan& Roof Plan

date

1:100

drawing no.

02revision

-

V:\M

IND

Hou

sing

\Lot

36

Tuss

ock

Dr,

Whi

tehi

lls\T

usso

ck W

DA0

1 - 2

5 M

ay 1

8.dw

gFI

LE N

AM

E:

Ballarat:424 Sturt Street (PO Box 772)Ballarat VIC 3350Phone: 03 5331 5977Fax: 03 5332 6599

Email: [email protected]

ARCHITECTSmorton dunn

Geelong:149 Pakington Street

Geelong West VIC 3218Phone: 03 5221 7885

Fax: 03 5221 7885

www.mortondunn.com.au

MIND Australia37 Tussock DriveWhite Hills

SupportedAccommodationResidence

PRELIMINARY

- 25 MAY 2018

ML

WDA

- -

proposed floor planscale 1:100 (A1)

N

NOTES:. REFER ALSO TO FLOOR PLANS ON INTERNAL ELEVATIONS FOR FURTHERDIMENSIONING AND FALL INFORMATION. ALL DOOR HARDWARE TO BE INSTALLED AT 1000mm AFL. REFER TO REFLECTED CEILING PLAN FOR DIMENSION SETOUT FOR CEILINGHOIST BEAMS (CONCEALED IN CEILING)

FIRE EXTINGUISHER NOTE:. EXTINGUISHER INSTALLATION SHALL BE SUCH THAT IT IS NOTLESS THAN 100MM ABOVE FFL, THE HANDLE IS LOCATED NOTMORE THAN 1200MM ABOVE FFL

REINFORCEMENT TO BATHROOM & TOILET WALLS NOTE:. PROVIDE 13MM PLYWOOD RECESSED INTO STUDS TOBOTTOM 900MM OF BATHROOM WALLS AS SHOWN HATCHEDON INTERNAL ELEVATIONS.. ALLOW REINFORCEMENT TO BE INSPECTED ANDPHOTOGRAPHED BY PRINCIPAL PRIOR TO LININGS BEINGINSTALLED

BEDROOM/ BATHROOM SETOUT:. BEDROOM AND BATHROOM DIMENSIONS ARE TO BE CHECKEDON SITE BY PRINCIPAL AT FRAMING STAGE TO ENSURECOMPLIANCE IS ACHIEVED.

NOTE:. ROOF TRUSSES ARE TO BE PITCHED AT 3000mm AFL.

Page 4: Notes - Disability Housing

Notes. This drawing is to be read in conjunction with other drawingsof the set.. No variation is to be made to this drawing without the priorapproval of the Principal and/or Superintendent.. This drawing is not to be scaled.. Contractor to verify all dimensions before commencingwork.. Ground levels indicated are approximate only and must beconfirmed on site prior to commencement.. All materials constructions etc. are to comply with allrelevant codes, by laws, Building Code of Australia, etc.. Foundations, excavations, reinforcement placement etc. tobe inspected and approved by the building surveyor prior toany concrete placement.. New concrete work is to comply with the requirements ofSAA code AS 3600 - 2001 and subsequent amendments - asapplicable.. Structural framing to be in accordance with AS 1684 TimberFraming Code. Structural Hardwood to have min stressgrading of F8 and Radiata Pine of F5 by approved testmethod.. Stormwater to be connected to existing system to approval.. All glazing to be in accordance with AS 1288 and AS2047.. All waterproofing to be in accordance with AS3740.. Smoke detectors (to comply with AS 3786) are to be installedin accordance with Building Code of Australia requirements.. Soil classification: refer soil test report.

COLORBONDBARGEBOARD

POWDERCOAT ALUMINIUMWINDOWS/ DOORS

STEEL COLUMN(PAINT FINISH)

194.700194.600

194.500194.400

194.300

193.500

COLORBOND 'CUSTOM-ORB'ROOF SHEETING

COLORBOND FASCIA& GUTTER

FACE BRICKWORK POWDERCOATALUMINIUM WINDOWS

COLORBOND 'CUSTOM-ORB'ROOF SHEETING

COLORBOND FASCIA& GUTTER

FACE BRICKWORK POWDERCOATALUMINIUM WINDOWS

FACE BRICKWORK

STEEL PERGOLA(PAINT FINISH)

LIGHTWEIGHTPOWDERCOAT CLADDING

FACE BRICKWORK

COLORBONDBARGEBOARD

COLORBOND 'CUSTOM-ORB'ROOF SHEETING

COLORBONDBARGEBOARD

FACE BRICKWORK POWDERCOATALUMINIUM WINDOWSCOLORBOND 'CUSTOM-ORB'

WALL SHEETING

STEEL PERGOLA(PAINT FINISH)

194.200

194.300

staffarea

commonarea

bed 2

living kitchen

Legend

R4.0 INSULATION 10mm GYPROCK SUPERCHEK WITH9mm VILLABOARD EXTERNALLY

25mm GYPROCK SHAFT LINER PANELBETWEEN H-STUDS AT 600mm CENTRES90 GOLD

BATTS 2.7

COLORBOND 'TRIMDEK' ROOFCLADDING @ 3° PITCH.

FIRE RESISTANTMINERAL WOOL

90mm TIMBERSTUD

16mm GYPROCKFYRCHEK

SUSPENDEDCEILING LINING

20mm GAP

typical internal 60/60/60fire rated wallscale 1:20 (A1)

NOTES:. FIRE RATED WALL IS TO BE IN ACCORDANCE WITH THEGYPROCK 'RED BOOK' SYSTEM CSR2405

10mm GYPROCKSUPERCHEK WITH9mm VILLABOARDEXTERNALLY

typical front door thresholdscale 1:10 (A1)

CONCRETE SLAB TOENGINEERS DESIGN &DETAIL

NGL

FL.

TIMBER DOOR

SECURITY DOOR

CONCRETE LANDINGMAX 1:40 SLOPE

FLOOR VINYL

WALL TILES TO WINDOWREVEAL AND SILL

SILICONE SEAL WALL/TILE/WINDOW REVEAL JUNCTION

4.5mm FC SHEET LINING TOENTIRE WINDOW REVEAL(INCLUDING UNDER TILES)

window reveal detail(wet areas)scale 1:10 (A1)

Morton Dunn Pty. Ltd. ACN 006 923 057 Copyright Reserved

Rev: Amendment: Date: Drawn:

sheet title

project status

job no.

scale @ A1 drawn checked approved

type

Proposed ElevationsSections

date

1:100

drawing no.

03revision

-

V:\M

IND

Hou

sing

\Lot

36

Tuss

ock

Dr,

Whi

tehi

lls\T

usso

ck W

DA0

1 - 2

5 M

ay 1

8.dw

gFI

LE N

AM

E:

Ballarat:424 Sturt Street (PO Box 772)Ballarat VIC 3350Phone: 03 5331 5977Fax: 03 5332 6599

Email: [email protected]

ARCHITECTSmorton dunn

Geelong:149 Pakington Street

Geelong West VIC 3218Phone: 03 5221 7885

Fax: 03 5221 7885

www.mortondunn.com.au

MIND Australia37 Tussock DriveWhite Hills

SupportedAccommodationResidence

PRELIMINARY

- 25 MAY 2018

ML

WDA

- -

south west elevationscale 1:100 (A1)

south east elevationscale 1:100 (A1)

north east elevationscale 1:100 (A1)

north west elevationscale 1:100 (A1)

section a-ascale 1:100 (A1)

section b-bscale 1:100 (A1)

section c-cscale 1:100 (A1)

NOTE:. GROUND LEVELS SHOWN ARE INDICATIVE ONLY. REFERTO SURVEY DRAWING FOR EXISTING LEVELS & FEATURES.

NOTE:. ROOF TRUSSES ARE TO BE PITCHED AT 3000mm AFL.

Page 5: Notes - Disability Housing

Notes. This drawing is to be read in conjunction with other drawingsof the set.. No variation is to be made to this drawing without the priorapproval of the Principal and/or Superintendent.. This drawing is not to be scaled.. Contractor to verify all dimensions before commencingwork.. Ground levels indicated are approximate only and must beconfirmed on site prior to commencement.. All materials constructions etc. are to comply with allrelevant codes, by laws, Building Code of Australia, etc.. Foundations, excavations, reinforcement placement etc. tobe inspected and approved by the building surveyor prior toany concrete placement.. New concrete work is to comply with the requirements ofSAA code AS 3600 - 2001 and subsequent amendments - asapplicable.. Structural framing to be in accordance with AS 1684 TimberFraming Code. Structural Hardwood to have min stressgrading of F8 and Radiata Pine of F5 by approved testmethod.. Stormwater to be connected to existing system to approval.. All glazing to be in accordance with AS 1288 and AS2047.. All waterproofing to be in accordance with AS3740.. Smoke detectors (to comply with AS 3786) are to be installedin accordance with Building Code of Australia requirements.. Soil classification: refer soil test report.

ensuite

a.wc

a.bath 1

kitchen

southensuite

V'BV'B V'B

southensuite

southensuite

V'B

southensuite

southa.bath 1

V'B

m.

SR

GRFS

southa.bath 1

southa.bath 1

southa.bath 1

V'BV'B

V'B

planensuite

plana.bath 1

southkitchen

plankitchen

V'B V'B V'B V'B V'B V'B

southkitchen

southkitchen

southkitchen

SR

southa.wc

V'B V'BV'B

V'B

m.

southa.wc

southa.wc

southa.wc

ALTRO 'C8' CAPTILE

SILICON SEAL

WALL TILES

FIBRE CEMENT SHEET(VILLABOARD)

150 MM HIGH COVING

PVC COVE FORMER

VINYL

WATERPROOF MEMBRANETO EXTEND 75MM MIN.UP WALL TO ENTIREPERIMETER OF BATHRM

100 X 50 UPVCANGLE COVE

PACKING TO FACEOF DOOR JAMB

APPROVED EPOXYADHESIVE FOR UPVCANGLE COVE

WATERPROOF MEMBRANE TOEXTEND FOR THE WHOLE OF THEFLOOR AREA

WATERPROOF MEMBRANE CORNERFLASHING TO EXTEND 1800MM MIN. UPCORNERS BEHIND THE WALL CLADDING

TREADSAFE FLOORFINISHING STRIP DT036

Morton Dunn Pty. Ltd. ACN 006 923 057 Copyright Reserved

Rev: Amendment: Date: Drawn:

sheet title

project status

job no.

scale @ A1 drawn checked approved

type

Internal Elevations 1

date

1:50

drawing no.

04revision

-

V:\M

IND

Hou

sing

\Lot

36

Tuss

ock

Dr,

Whi

tehi

lls\T

usso

ck W

DA0

1 - 2

5 M

ay 1

8.dw

gFI

LE N

AM

E:

Ballarat:424 Sturt Street (PO Box 772)Ballarat VIC 3350Phone: 03 5331 5977Fax: 03 5332 6599

Email: [email protected]

ARCHITECTSmorton dunn

Geelong:149 Pakington Street

Geelong West VIC 3218Phone: 03 5221 7885

Fax: 03 5221 7885

www.mortondunn.com.au

MIND Australia37 Tussock DriveWhite Hills

SupportedAccommodationResidence

PRELIMINARY

- 25 MAY 2018

ML

WDA

- -

internal elevations 1scale 1:50 (A1)

typical wall vinyl/ floor vinyljunctionscale 1:20 (A1)

typical carpet/floor vinyl detailscale 1:2 (A1)

Page 6: Notes - Disability Housing

Notes. This drawing is to be read in conjunction with other drawingsof the set.. No variation is to be made to this drawing without the priorapproval of the Principal and/or Superintendent.. This drawing is not to be scaled.. Contractor to verify all dimensions before commencingwork.. Ground levels indicated are approximate only and must beconfirmed on site prior to commencement.. All materials constructions etc. are to comply with allrelevant codes, by laws, Building Code of Australia, etc.. Foundations, excavations, reinforcement placement etc. tobe inspected and approved by the building surveyor prior toany concrete placement.. New concrete work is to comply with the requirements ofSAA code AS 3600 - 2001 and subsequent amendments - asapplicable.. Structural framing to be in accordance with AS 1684 TimberFraming Code. Structural Hardwood to have min stressgrading of F8 and Radiata Pine of F5 by approved testmethod.. Stormwater to be connected to existing system to approval.. All glazing to be in accordance with AS 1288 and AS2047.. All waterproofing to be in accordance with AS3740.. Smoke detectors (to comply with AS 3786) are to be installedin accordance with Building Code of Australia requirements.. Soil classification: refer soil test report.

l'dry

a.bath 2

southkitchen

planlaundry

V'BV'B

V'B V'B

southkitchen

southkitchen

southkitchen

southa. bath 2

plana.bath 2

southa. bath 2

southa. bath 2

southa. bath 2

SR

GRFS

SR

LAMINATE BENCHTOPAND JOINERY

WHITE MELAMINECARCASS

SILICON SEALTO FLOOR

kitchen bench sectionscale 1:20 (A1)

vanity unit sectionscale 1:20 (A1)

ensuite vanityunit sectionscale 1:20 (A1)

ALL EXPOSEDPIPEWORK TO BECHROME FINISH

NOTE: VANITY UNIT AND BASIN CLEARANCESTO BE IN ACCORDANCE WITH AS1428.1-2009

typical vanity unitelevationscale 1:20 (A1)NOTE:. VANITY UNIT AND BASIN CLEARANCES TO BEIN ACCORDANCE WITH AS1428.1-2009

LAMINATE BENCHTOP,DOWNTURN AND JOINERY

ALL EXPOSEDPIPEWORK TO BECHROME FINISH

SILICON SEALLAMINATE ANDVINYL JUNCTION

FLOOR VINYL TO EXTENDUNDER BENCH

LED TASKLIGHTING

LAMINATESHELVING

typical vanity unitelevationscale 1:20 (A1)NOTE:. VANITY UNIT AND BASIN CLEARANCES TO BEIN ACCORDANCE WITH AS1428.1-2009

LAMINATEBENCHTOP,DOWNTURNAND JOINERY

ALL EXPOSEDPIPEWORK TO BECHROME FINISH

LAMINATESHELVING

1020mm SOLIDCORE DOOR

Morton Dunn Pty. Ltd. ACN 006 923 057 Copyright Reserved

Rev: Amendment: Date: Drawn:

sheet title

project status

job no.

scale @ A1 drawn checked approved

type

Internal Elevations 2

date

1:50

drawing no.

05revision

-

V:\M

IND

Hou

sing

\Lot

36

Tuss

ock

Dr,

Whi

tehi

lls\T

usso

ck W

DA0

1 - 2

5 M

ay 1

8.dw

gFI

LE N

AM

E:

Ballarat:424 Sturt Street (PO Box 772)Ballarat VIC 3350Phone: 03 5331 5977Fax: 03 5332 6599

Email: [email protected]

ARCHITECTSmorton dunn

Geelong:149 Pakington Street

Geelong West VIC 3218Phone: 03 5221 7885

Fax: 03 5221 7885

www.mortondunn.com.au

MIND Australia37 Tussock DriveWhite Hills

SupportedAccommodationResidence

PRELIMINARY

- 25 MAY 2018

ML

WDA

- -

internal elevations 2scale 1:50 (A1)

typical door clearancesscale 1:20 (A1)

Page 7: Notes - Disability Housing

Notes. This drawing is to be read in conjunction with other drawingsof the set.. No variation is to be made to this drawing without the priorapproval of the Principal and/or Superintendent.. This drawing is not to be scaled.. Contractor to verify all dimensions before commencingwork.. Ground levels indicated are approximate only and must beconfirmed on site prior to commencement.. All materials constructions etc. are to comply with allrelevant codes, by laws, Building Code of Australia, etc.. Foundations, excavations, reinforcement placement etc. tobe inspected and approved by the building surveyor prior toany concrete placement.. New concrete work is to comply with the requirements ofSAA code AS 3600 - 2001 and subsequent amendments - asapplicable.. Structural framing to be in accordance with AS 1684 TimberFraming Code. Structural Hardwood to have min stressgrading of F8 and Radiata Pine of F5 by approved testmethod.. Stormwater to be connected to existing system to approval.. All glazing to be in accordance with AS 1288 and AS2047.. All waterproofing to be in accordance with AS3740.. Smoke detectors (to comply with AS 3786) are to be installedin accordance with Building Code of Australia requirements.. Soil classification: refer soil test report.

SOLID CORE DOORS(PAINT FINISH)

typical wardrobe/ desk elevationscale 1:20 (A1)

DR

DR

DR

FIXED LAMINATED 3 DRAWERUNIT 450mm WIDE. LOCATETO ENSURE DRAWERS CLEARDOOR WHEN OPEN.

16mm LAMIANTEVENEERED DRAWERFRONT 100mm SATINCHROME 'D' PULL

18mm LAMINATEDVENEERED SHELF

13mm MELAMINEVENEERED DRAWER

typical wardrobe sectionscale 1:20 (A1)

MELAMINE FACE PANEL

MELAMINE SHELVING

IC.PB

25mm diam. CHROMEPLATED HANGING RAILFIXED TO SHELF WITHBRACKETS AT 800CTRS.max.

100mm SATIN CHROME'D-PULLS' LOCATED 950 TO1050 ABOVE FLOOR LEVEL.

18MM MELAMINE LAMINATEDFULL WIDTH FIXED SHELF

100mm SATINCHROME 'D' PULLS

FLUSH PANEL DOOR

FIXED MELAMINEVENEERED SHELF

linen cupboardscale 1:20 (A1)

ADJUSTABLE MELAMINEVENEERED SHELVING

50 inch tv

PROVIDE 13MMPLYWOOD RECESSEDINTO STUDS

IC.PB

tv a

lcov

e

18mm KDHWREVEAL (PAINTFINISH) SOUNDSCREEN R2.5

ACOUSTIC INSULATION

typical tv alcove planscale 1:20 (A1)

PROVIDE 13MMPLYWOODRECESSED INTOSTUDS

1no. LAYER OF13mm IMPACTCHEKPLASTERBOARD

1no. LAYER OF13mm IMPACTCHEKPLASTERBOARD

1no. LAYER OF13mm IMPACTCHEKPLASTERBOARD

37LETTERBOX INSERTAS SPECIFIED

FACE BRICKWORK

CONCRETECAPPING(PAINTFINISH)

CONCRETE CAPPING(PAINT FINISH)

BRICKMAILBOXES

350x350 BRICK PIERS WITHCONCRETE CAPPING (PAINT FINISH)

POWDERCOATSTEEL FENCE

1000mmWIDE GATE

Morton Dunn Pty. Ltd. ACN 006 923 057 Copyright Reserved

Rev: Amendment: Date: Drawn:

sheet title

project status

job no.

scale @ A1 drawn checked approved

type

Details

date

1:50

drawing no.

06revision

-

V:\M

IND

Hou

sing

\Lot

36

Tuss

ock

Dr,

Whi

tehi

lls\T

usso

ck W

DA0

1 - 2

5 M

ay 1

8.dw

gFI

LE N

AM

E:

Ballarat:424 Sturt Street (PO Box 772)Ballarat VIC 3350Phone: 03 5331 5977Fax: 03 5332 6599

Email: [email protected]

ARCHITECTSmorton dunn

Geelong:149 Pakington Street

Geelong West VIC 3218Phone: 03 5221 7885

Fax: 03 5221 7885

www.mortondunn.com.au

MIND Australia37 Tussock DriveWhite Hills

SupportedAccommodationResidence

PRELIMINARY

- 25 MAY 2018

ML

WDA

- -

tussock street elevationscale 1:100 (A1)

NOTE:. REFER TO ENGINEERS DETAILS FOR MAILBOX FOOTINGDESIGN AND DETAIL. FINAL UNIT NUMBERS TO BE CONFIRMED WITH COUNCIL