Upload
duongnhi
View
227
Download
3
Embed Size (px)
Citation preview
RE 64656, edition: 2015-01, Bosch Rexroth AG
▶ Size 6 ▶ Component series 3X ▶ Maximum control pressure 30 bar ▶ Maximum flow of 40 l/min
Proportional pressure reducing valve, direct operated, decreasing characteristic curve
Features
▶ Direct operated proportional pressure reducing valve for reducing the system pressure
▶ Pilot control valve ▶ Screw-in cartridge valve ▶ Suitable for mobile applications ▶ Operation by means of proportional solenoid ▶ In case of power failure, the maximum pressure is set ▶ Recommended control electronics:
Type RA and RC mobile amplifiers
RE 64656Edition: 2015-01
H8039
Type MHDRE 06 FK (high-performance)
Contents
Features 1Ordering code 2Valve types 2Function, section, symbol 3Technical data 4, 5Admissible working range 5Characteristic curves 6, 7Dimensions 8Mounting cavity 9Individual components available 10Further information 10
Contents
Features 1Ordering code 1) 2
Valve types 2Function, section, symbol 3Technical data (For applications outside these parameters, please consult us.) 4Technical data (For applications outside these parameters, please consult us.) 5Admissible working range 5Characteristic curves (measured with HLP46, ϑoil= 40 ± 5 °C ) 6Characteristic curves with tolerance band (measured with HLP46, oil = 40 ± 5 °C) 7Dimensions (dimensions in mm) 8Mounting cavity R/MHDRE 06; 3 main ports (dimensions in mm) 9Individual components available 10Further information 10Notes 11Notes 12
2/10 MHDRE 06 FK | Proportional pressure reducing valve
Bosch Rexroth AG, RE 64656, edition: 2015-01
Ordering code 1)
01 Proportional pressure reducing valve, direct operated MHDRE
02 Size 6 06
03 Decreasing characteristic curve F
04 Screw-in cartridge valve K
05 Component series 30 … 39 (30 … 39; unchanged installation and connection dimensions) 3X
06 Maximum control pressure 18 bar 18Maximum control pressure 30 bar 30
07 Proportional solenoid, wet-pin A
Supply voltage08 Control electronics 24 V DC (12 V DC on request) G24
Electrical connection 1)
09 Without mating connector; connector DIN EN 175301-803 K4Without mating connector, with connector DT 04-2P (Deutsch connector) K40Without mating connector, with connector AMP Junior-Timer C4
Seal material10 FKM seals V
Observe compatibility of seals with hydraulic fluid used! (Other seals on request)
11 Further details in plain text *
01 02 03 04 05 06 07 08 09 10 11
MHDRE 06 F K 3X / A G24 V *
Valve types
1) Mating connectors, separate order, see data sheet 08006.
Type Material number
MHDRE 06 FK3X/18AG24C4V R901297359
MHDRE 06 FK3X/30AG24C4V R901297364
���
���
�
�
� ���
�
�
�
Proportional pressure reducing valve | MHDRE 06 FK 3/10
RE 64656, edition: 2015-01, Bosch Rexroth AG
Function, section, symbol
GeneralThe type MHDRE 06 FK proportional pressure reducing valve is a direct operated, 3-way version screw-in cartridge valve. It reduces the control pressure (main port ①) pro-portionally to the solenoid current and largely works inde-pendently of the inlet pressure (main port ②).When the command value = 0 or in the event of power failure, the maximum pressure is set. It is actuated using a proportional solenoid. The solenoid's interior is connected to the main port ③ and filled with hydraulic fluid.Depending on the electric command value, these valves can be used to continuously reduce the system pressure. The valve is suitable for controlling couplings, pumps, and directional valves, and is also suitable for use in propor-tional pilot controls (especially in mobile applications).
Basic principleThe valve controls the pressure in the main port ① in accordance with the current on the solenoid. The “F” version signifies a decreasing characteristic curve, i.e. an increasing current brings about a reduced pressure (see characteristic curves on pages 6 and 7). The proportional solenoid converts the electric current into mechanical force that acts upon the piston via the armature. The piston controls the connection between the main ports.
Notes:The tank pressure that occurs (main port 3 ) is added to the control pressure (main port 1 ).
Version “C4”
Version “K40”
Version “K4” (with mating connector)
① = main port 1 (A)② = main port 2 (P)③ = main port 3 (T)
4/10 MHDRE 06 FK | Proportional pressure reducing valve
Bosch Rexroth AG, RE 64656, edition: 2015-01
Technical data (For applications outside these parameters, please consult us.)
GeneralWeight kg 0,7Installation position any - if it is ensured that no air can collect upstream the valve.
Otherwise, we recommend suspended installation of the valve.Ambient temperature range °C See “Admissible working range” on page 5Storage temperature range °C –40 … +80Salt spray test according to EN ISO 9227 h 720 (NSS test)Solenoid surface protection Coating according to DIN 50962-Fe//ZnNi with thick film
passivation
HydraulicMaximum control pressure ▶ main port ① bar 18; 30Maximum inlet pressure ▶ main port ② bar 100Maximum counter pressure ▶ Main port ③ bar Depressurized (max. 100 bar; the tank pressures that occur are
added to the control pressure (main port ①))Maximum flow l/min see characteristic curves page 6Maximum leakage ▶ Main port ③ ml/min 120 (50 bar in ②; I = 0 mA, 46 cSt)Maximum pilot oil ml/min 120 (50 bar in ②; I = Imax, 46 cSt)Hydraulic fluid See table belowHydraulic fluid temperature range °C –40 … +120Viscosity range mm2/s 5 … 400Maximum permissible degree of contamination of the hy-draulic fluid, cleanliness class according to ISO 4406 (c)
Class 20/18/15 1)
Hysteresis (within the tolerance band) bar ≤ 1.5 (control pressure 18 bar) ≤ 2.0 (control pressure 30 bar)
Step response (Tu + Tg) 0 → 100 % and/or 100 % → 0 ms ≤ 100 (50 bar in ②; 46 cSt, qV = 0 l/min, dead volume in ① 140 cm3)Repetition accuracy % < 2 % of the maximum control pressureLoad cycles 10 millionStrainer element on the main port ② (P) µm 240
1) The cleanliness classes stated for the components need to be maintained in hydraulic systems. Effective filtration prevents faults and at the same time increases the life cycle of the components.
For the selection of the filters see www.boschrexroth.com/filter. We recommend using a filter with a minimum retention rate of
ß10 ≧ 75.
Hydraulic fluid Classification Suitable sealing materials
Standards Data sheet
Mineral oils HL, HLP NBR, FKM DIN 51524 90220Bio-degradable ▶ Insoluble in water HEES FKM ISO 15380 90221
▶ Soluble in water HEPG FKM ISO 15380
Important information about hydraulic fluids: ▶ For more information and data about the use of other hydraulic fluids, refer to data sheets above or contact us!
▶ There may be limitations regarding the technical valve data (tem-perature, pressure range, life cycle, maintenance intervals, etc.)!
▶ The flash point of the hydraulic fluid used must be 40 K higher than the maximum solenoid surface temperature.
▶ Bio-degradable: When using bio-degradable hydraulic fluids that are also zinc-solving, zinc may accumulate in the fluid (700 mg zinc per pole tube).
���
���
��
��
��
��
���� ��� � �� �� �� �� �� ���
�
�
��� �� �� �� �� ����
��� ���
��
��
��
��
���
���
���
���
���
���
Proportional pressure reducing valve | MHDRE 06 FK 5/10
RE 64656, edition: 2015-01, Bosch Rexroth AG
When establishing the electrical connection, the protective earthing conductor (PE ) must be connected correctly.
Technical data (For applications outside these parameters, please consult us.)
2) Consultation is recommended for use at > 2000 m above sea level.3) Due to the surface temperatures of the solenoid coils, the
ISO 13732-1 and ISO 4413 standards must be adhered to.4) The chopper frequency should be optimized for the application.
The working temperature range should be taken into consideration.
ElectricalSupply voltage V 12 DC 24 DCMaximum control current A 1,45 0,7Coil resistance at 20 °C Ω 5 22,5Duty cycle (ED) 2) % 100Maximum coil temperature 3) °C 185Protection class according to DIN EN 60529
▶ Version “K4” IP 65 with mating connector mounted and locked ▶ Version “C4” IP 66 with mating connector mounted and locked
IP 69K with Rexroth mating connector, material no. R901022127 ▶ Version “K40” IP 69K with mating connector mounted and locked
Chopper frequency (recommended) 4) Hz 150Control electronics Analog amplifier type RA... (Data sheet 95230)
BODAS control unit type RC... (Data sheet 95200)Design according to VDE 0580
Note: ▶ The technical data was determined at a viscosity of v = 46 mm2/s (HLP46; ϑoil = 40 °C)
▶ The following documentation must be observed: 64020-B1 Hydraulic valves for mobile applications
Admissible working range
Ambient temperature in °C →
Ope
ratin
g vo
ltage
in %
of n
omin
al v
olta
ge →
1 Required operating voltage in % of nominal voltage2 Admissible continuous application of current in % of nominal current
Admissible working range depending on ambient temperature
Adm
issi
ble
cont
inuo
us a
pplic
atio
n of
cur
rent
in
% o
f nom
inal
cur
rent
→
�
�
�
��
��
��
������
� �� �� �� �� �� �� ��
����
����
��
�
�
�
��
��
��
������
� �� �� �� �� �� �� ��
�
�
����
��
Flow in l/min →
Pres
sure
diff
eren
tial i
n ba
r →
Control pressure 30 bar
1 ① → ③2 ② → ①
6/10 MHDRE 06 FK | Proportional pressure reducing valve
Bosch Rexroth AG, RE 64656, edition: 2015-01
Characteristic curves (measured with HLP46, ϑoil= 40 ± 5 °C )
Flow in l/min →
Pres
sure
diff
eren
tial i
n ba
r →
Control pressure 18 bar
∆p-qV-characteristic curve
1 ① → ③2 ② → ①
�
�
��
�������
��������
��
����
���
���
��� ������ ��� ��� ��� ��� ���
�
�
��
��
��
��
��
��
��
����
����
��
�
��� ������ ��� ��� ������ ���
Proportional pressure reducing valve | MHDRE 06 FK 7/10
RE 64656, edition: 2015-01, Bosch Rexroth AG
Characteristic curves with tolerance band (measured with HLP46, oil = 40 ± 5 °C)
Control current in A →
Set
pres
sure
at
mai
n po
rt ①
in
bar →
Control pressure 30 bar
Control current in A →
Set
pres
sure
at
mai
n po
rt ①
in
bar →
Control pressure 18 bar
���
���
����
�
�
�
����
����
��
���
��
�
�
����
������������
�
�
�
�
���
8/10 MHDRE 06 FK | Proportional pressure reducing valve
Bosch Rexroth AG, RE 64656, edition: 2015-01
Dimensions (dimensions in mm)
1 Mating connector for connector “K4” (separate order, see data sheet 08006)
2 Mating connector for connector “C4” (separate order, see data sheet 08006)
3 Mating connector for connector “K40” (separate order, see data sheet 08006)
4 Space required to remove the mating connector5 SW28 hexagon; tightening torque MA = 10+2 Nm6 Solenoid nut, tightening torque MA = 5+1 Nm7 Strainer element
① = main port 1 (A)② = main port 2 (P)③ = main port 3 (T)
LS = Location shoulder
�����
���������
� ������� �
������������
������ ���
���
����
����
����
���
����
����
��
������
���
�����
����
�
����
����
����
���
����
����
���
�
�
�
��������
�� �����
��
��
�
�
��������
���
�����
����� �
������ �
���������������� �
�
���� �
��������
���������
�� ��
�������������
���
����
�� ��
���� �����������
��������
Proportional pressure reducing valve | MHDRE 06 FK 9/10
RE 64656, edition: 2015-01, Bosch Rexroth AG
Mounting cavity R/MHDRE 06; 3 main ports (dimensions in mm)
1) Depth of fit2) Visual inspection
Standards:Workpiece edges DIN ISO 13715Form and position tolerance DIN EN ISO 1101General tolerances for metal-cut-ting procedures
DIN ISO 2768-mK
Tolerance DIN ISO 8015Surface condition DIN EN ISO 1302
View “X”
① = main port 1 (A)② = main port 2 (P)③ = main port 3 (T)
LS = Location shoulder
Bosch Rexroth AG, RE 64656, edition: 2015-01
10/10 MHDRE 06 FK | Proportional pressure reducing valve
Bosch Rexroth AG HydraulicsZum Eisengiesser 197816 Lohr am Main, Germany Phone +49 (0) 93 52 / 18-0 [email protected] www.boschrexroth.de
© All rights for this document, are the property of Bosch Rexroth AG, including registrations of industrial property rights. It may not be reproduced or trans-ferred to third parties without our consent.The data specified only serve to describe the product. No conclusions concern-ing a certain condition or suitability for a certain application can be derived from our information. The information provided does not release the user from the obligation to exercise their own judgment and verification. It should be taken into consideration that our products are subject to a natural process of wear and aging.
Individual components available
Further information
▶ Control electronics: – Analog amplifier type RA… Data sheet 95230
– BODAS control unit type RC… Data sheet 95200
▶ Hydraulic valves for mobile applications Data sheet 64020-B1 ▶ Mineral oil-based hydraulic fluids Data sheet 90220 ▶ Environmentally compatible hydraulic fluids Data sheet 90221 ▶ Filter range www.boschrexroth.com/filter
Item Designation Material no.998 Nut GZ45-01V BG R961004245999 Valve seal kit R961003854920 O-ring R900002507
999 920 998
Bosch Rexroth AG HydraulicsZum Eisengiesser 197816 Lohr am Main, Germany Phone +49 (0) 93 52 / 18-0 [email protected] www.boschrexroth.de
© All rights for this document, are the property of Bosch Rexroth AG, including registrations of industrial property rights. It may not be reproduced or trans-ferred to third parties without our consent.The data specified only serve to describe the product. No conclusions concern-ing a certain condition or suitability for a certain application can be derived from our information. The information provided does not release the user from the obligation to exercise their own judgment and verification. It should be taken into consideration that our products are subject to a natural process of wear and aging.
Proportional pressure reducing valve | MHDRE 06 FK 11/10
RE 64656, edition: 2015-01, Bosch Rexroth AG
Notes
Bosch Rexroth AG, RE 64656, edition: 2015-01
12/10 MHDRE 06 FK | Proportional pressure reducing valve
Bosch Rexroth AG HydraulicsZum Eisengiesser 197816 Lohr am Main, Germany Phone +49 (0) 93 52 / 18-0 [email protected] www.boschrexroth.de
© All rights for this document, are the property of Bosch Rexroth AG, including registrations of industrial property rights. It may not be reproduced or trans-ferred to third parties without our consent.The data specified only serve to describe the product. No conclusions concern-ing a certain condition or suitability for a certain application can be derived from our information. The information provided does not release the user from the obligation to exercise their own judgment and verification. It should be taken into consideration that our products are subject to a natural process of wear and aging.
Notes