ELECTRICALTITLE SHEET
APPLICABLE CODES
1. 2013 BUILDING STANDARD ADMINISTRATIVE CODE, PART 1, TITLE 24 C.C.R.2. 2013 CALIFORNIA BUILDING CODE (CBC), PART 2, TITLE 24 C.C.R.;
(2014 EMERGENCY SUPPLEMENT)3. 2013 CALIFORNIA ELECTRICAL CODE (CEC), PART 3, TITLE 24 C.C.R.;
(2011 NATIONAL ELECTRICAL CODE & 2013 CALIFORNIA AMENDMENT)4. 2013 CALIFORNIA MECHANICAL CODE (CMC), PART 4, TITLE 24 C.C.R.;
(2012 UNIFORM MECHANICAL CODE & 2013 CALIFORNIA AMENDMENT)5. 2013 CALIFORNIA PLUMBING CODE (CPC), PART 5, TITLE 24 C.C.R.;
(2012 UNIFORM PLUMBING CODE & 2013 CALIFORNIA AMENDMENT)6. 2013 CALIFORNIA ENERGY CODE, PART 6, TITLE 24 C.C.R.;7. 2013 CALIFORNIA FIRE CODE (CFC), PART 9, TITLE 24, C.C.R.;
(2014 CALIFORNIA AMENDMENT)9. 2013 CALIFORNIA EXISTING BUILDING CODE, PART 10, TITLE 24 C.C.R
(2014 CALIFORNIA SUPPLEMENTS)10. 2013 CALIFORNIA "GREEN" BUILDING REQUIREMENTS, PART 11, TITLE 24 C.C.R (PENDING ADOPTION)11. 2013 CALIFORNIA REFERENCED STANDARDS CODE, PART 12, TITLE 24, C.C.R.12. TITLE 19, CCR, PUBLIC SAFETY, STATE FIRE MARSHAL REGULATIONS
SHEET INDEX
ABBREVIATIONSA AMPEREAC ALTERNATING CURRENTAF AMPERE RATING OF FUSEAFF ABOVE FINISHED FLOORC CONDUITCKT CIRCUITCL CENTERLINED DEDICATEDDN DOWN(E) EXISTING TO REMAINELEC ELECTRICALEM EMERGENCYEMT ELECTRICAL METALLIC TUBING(F) FUTUREFACP FIRE ALARM CONTROL PANELFATC FIRE ALARM TERMINAL CANG GROUNDING CONDUCTORGFI GROUND FAULT INTERRUPTERGND GROUNDHP HORSEPOWERkVA KILOVOLT AMPSkW KILOWATTSLTG LIGHTINGLTS LIGHTSLV LOW VOLTAGEMECH MECHANICAL
MTD MOUNTEDMV MEDIUM VOLTAGEN NEUTRAL(N) NEWN.E.C. NATIONAL ELECTRICAL CODENEMA NATIONAL ELECTRICAL MANUFACTURERSASSOC.NEUT NEUTRALNIC NOT IN CONTRACTNTS NOT TO SCALEPB PULL BOXPNL PANELPTZ PAN TILT ZOOMRR REMOVE AND RELOCATERSC RIGID STEEL CONDUITSLD SINGLE LINE DIAGRAM SPEC SPECIFICATIONT TELEPHONETV TELEVISIONUG UNDERGROUNDUAC UNDER ANOTHER CONTRACTUON UNLESS OTHERWISE NOTEDV VOLTVP VANDAL PROOFW WATTSWP WEATHERPROOF (NEMA 3R)WT WATERTIGHTXFMR TRANSFORMER
SYMBOLS (NOTE: NOT ALL SYMBOLS USED)
1. ALL WORK IS TO BE PERFORMED IN STRICT COMPLIANCE WITH THE NATIONAL ELECTRIC CODE, STATE LAWS, AND ALL OTHER REGULATIONS GOVERNING WORK OF THISNATURE.
2. CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH THE EXISTING JOB CONDITION. HE SHALL EXAMINE CONSTRUCTION DRAWINGS AND SPECIFICATIONS AND SHALL HAVE HADVISITED THE CONSTRUCTION SITE, PRIOR TO SUBMITTING HIS BID PROPOSAL. HE SHALL BE FAMILIAR WITH THE EXISTING CONDITIONS UNDER WHICH HE WILL HAVE TOOPERATE AND WHICH WILL IN ANY WAY AFFECT THE WORK UNDER THIS CONTRACT. NO SUBSEQUENT ALLOWANCE WILL BE MADE IN THIS CONNECTION IN BEHALF OF THECONTRACTOR FOR ANY ERROR OR NEGLIGENCE ON HIS PART. DETERMINE THE SEQUENCE OF CONSTRUCTION THROUGHOUT THE PROJECT, INCLUDING TEMPORARYFACILITIES AND CONNECTIONS REQUIRED FOR THE DURATION OF THE PROJECT.
3. THE CONTRACTOR SHALL SECURE ALL PERMITS OR APPLICATIONS, AND PAY ANY AND ALL FEES AS REQUIRED.
4. EXISTING ARCHITECTURAL SURFACES DISTURBED DURING CONSTRUCTION SHALL BE PATCHED AND PAINTED TO MATCH EXISTING.
5. WORK SHOWN IN THESE PLANS ARE NEW, UON. INSTALLATION SHALL BE CONCEALED. WHERE NOT POSSIBLE, CONTRACTOR SHALL OBTAIN APPROVAL FROM ARCHITECT ANDENGINEER FOR EXPOSED INSTALLATION. A WRITTEN APPROVAL IS REQUIRED. USE SURFACE RACEWAYS, WIREMOLD, OR EQUAL. ALL ELECTRIC MATERIALS, DEVICES, ANDEQUIPMENT FOR THE PROJECT SHALL BE NEW AND U.L. APPROVED.
6. ALL CONDUIT SHALL BE 3/4" MINIMUM. ALL CONDUIT SHALL BE RUN PARALLEL TO EXISTING SURFACES. WHEN CONDUIT CROSSES CORRIDORS OR ROOMS IT SHALL BE DONEPERPENDICULAR TO WALLS. PAINT CONDUIT TO MATCH EXISTING SURFACES. REFER TO ARCHITECTURAL SPECIFICATIONS.
7. SEAL ALL CONDUIT PENETRATIONS THROUGH FIRE RATED WALLS. FURNISH AND INSTALL FIRE RATED BACKBOXES AS REQUIRED TO MAINTAIN FIRE RATING OF CEILING ORWALLS WHERE RECESSED ELECTRIC EQUIPMENT SUCH AS LIGHT FIXTURES, SWITCHES, RECEPTACLES, PANEL, ETC. ARE INSTALLED IN RATED WALL OR CEILINGS.PENETRATIONS OF FIRE RATED WALLS, CEILINGS, OR FLOORS SHALL COMPLY WITH CBC CHAPTER 7 REQUIREMENTS. IN WALLS AND PARTITIONS THAT ARE FOR FIRERESISTIVE CONSTRUCTION, OPENINGS FOR STEEL ELECTRICAL OUTLET BOXES SHALL NOT EXCEED 16 SQUARES INCHES. IN ADDITION, THE AGGREGRATE AREA OF SUCHOPENING SHALL NOT EXCEED 100 SQ IN FOR ANY 100 SQUARE FEET OF WALL OR PARTITION. OUTLET BOXES ON OPPOSITE SIDES OF THE WALLS OR PARTITION SHALL BESEPARATED BY A HORIZONTAL DISTANCE OF AT LEAST 24 INCHES, OR BE PROVIDED WITH FIRE PUTTY.
8. ALL NEW WIRING SHALL BE IN CONDUIT. COORDINATE ROUTING OF CONDUIT WITH ARCHITECT AND STRUCTURAL FOR OPENINGS IN WALLS AND ANY NOTCHING OF JOISTS.
9. THE ELECTRICAL PLANS ARE SCHEMATIC IN NATURE AND ARE NOT INTENDED TO SHOW ALL OF THE ARCHITECTURAL DETAILS OR SPECIFICS OF ELECTRICAL CONSTRUCTION.TAKE ALL DIMENSIONS FROM THE ARCHITECTURAL DRAWINGS. BEFORE ROUGH-IN, VERIFY ALL MOUNTING HEIGHTS AND EXACT LOCATIONS FOR ALL EQUIPMENT ELECTRICALCONNECTIONS, STUB-UPS, RECEPTACLES, OUTLETS, CONDUIT RUNS, ETC. WITH ARCHITECT AND OWNER. PLACE DEVICES LOCATED ABOVE COUNTERS, SHELVING, ETC. ANDIN BATHROOMS SO AS NOT TO CONFLICT WITH EDGES OF WAINSCOTING, COUNTER SPLASH, SHELVING, ETC. ARCHITECTURAL SHEETS SHALL GOVERN. SEE ELECTRICALSECTION OF ARCHITECTURAL SPECIFICATION FOR ADDITIONAL INFORMATION.
10. PULLROPES: ANY RACEWAY WITHOUT CABLE OR WIRE SHALL BE INSTALLED WITH MINIMUM 200 POUND TEST PULL LINE AND LARGER.
11. ALL DEVICES AND EQUIPMENT INSTALLED OUTDOORS OR EXPOSED TO THE WEATHER SHALL BE OF WEATHERPROOF CONSTRUCTION. ALL WALL PENETRATIONS TOEXTERIOR WALLS SHALL BE SEALED WATER TIGHT.
12. ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A NATIONALLY RECOGNIZED TESTING LABORATORY AND SHALL BE INSTALLED AS PER LISTING OR LABELING (IE. MAXIMUMFUSE SIZE MEANS FUSE PROTECTION IS REQUIRED).
13. ALL EQUIPMENT MANUFACTURERS SHALL BE NOTED IN DRAWINGS. EQUIPMENT SHALL BE PER SFUSD STANDARD. NO SUBSTITUTIONS PERMITTED.
14. GROUNDING CONDUCTORS ARE GENERALLY NOT SHOWN. GROUND AND BOND ALL EQUIPMENT, RACEWAYS, MOTORS, PANELBOARDS AND SWITCHBOARDS, ETC. INACCORDANCE WITH NEC ARTICLE 250.
15. FIELD MOUNTED DEVICES SUCH AS SWITCHES, MOTOR STARTERS, RECEPTACLES, ETC., ARE SHOWN IN THEIR APPROXIMATE LOCATION. SWITCH MOUNTING HEIGHT SHALLBE 48" ABOVE FINISHED FLOOR AND RECEPTACLE MOUNTING HEIGHT SHALL BE 18" ABOVE FINISHED FLOOR. CONTRACTOR SHALL COORDINATE WITH ALL TRADES FORMANUFACTURER INSTALLATION REQUIREMENTS.
16. ELECTRICAL CONTRACTOR TO PROVIDE EXPANSION FITTINGS AT ALL EXPANSION JOINT LOCATION. USE STEEL FLEX 6 FEET EACH SIDE OF THE JOINT AND TERMINATE IN APULLBOX AT EACH END, OR OTHER APPLIED METHODS.
17. ALL ELECTRICAL EQUIPMENT SHALL BE INSTALLED TO MAINTAIN A MINIMUM OF 36" CLEARANCE PER NEC ARTICLE 110.26.
18. PENETRATIONS OF FIRE RATED WALLS CEILINGS OR FLOORS SHALL COMPLY WITH CBC CHAPTER 7 REQUIREMENTS.
19. WHERE OUTLET BOXES ARE INSTALLED WITHIN RATED ASSEMBLIES, PROVIDE 3M MOLDABLE PUTTY PADS OR EQUAL TO MAINTAIN FIRE RATED ASSEMBLIES.
20. ALL RECEPTACLES SHALL BE GROUNDING TYPE.
21. SUBMIT TO THE OWNER CERTIFICATES OF INSPECTIONS IN DUPLICATE FROM AN APPROVED INSPECTION AGENCY UPON COMPLETION.
22. PERFORMANCE AND WITNESSING OF TESTS
A. THE CONTRACTOR SHALL FURNISH ALL INSTRUMENTS AND QUALIFIED PERSONNEL OR FIRM TO PERFORM ALL REQUIRED TESTS.B. ALL NEW AND RECONNECTED ELECTRICAL CIRCUIT SHALL BE TESTED TO INSURE CIRCUIT CONTINUITY, INSULATION RESISTANCE, PROPER SPLICING AND GROUNDING IN
ACCORDANCE WITH THE LATEST STANDARDS AS STATED ABOVE. BEFORE CONNECTING POWER CABLES TO MOTORS, THE INSULATION RESISTANCE OF ALL MOTORWINDINGS SHALL BE TESTED IN ACCORDANCE WITH THE ABOVE STANDARDS.
C. ANY CONTRACTOR FURNISHED AND/OR INSTALLED SPLICE, RECOMMENDED VOLTAGE AND INSULATION RESISTANCE TESTS, SHALL BE CONNECTED OR REPLACED BYTHE CONTRACTOR AT HIS EXPENSE.
D. NO EQUIPMENT SHALL BE ENERGIZED UNTIL ALL TESTS AND ADJUSTMENTS HAVE BEEN MADE.E. THREE COPIES OF ALL TEST RESULTS SHALL BE DELIVERED TO THE OWNER.
GENERAL NOTES
DUPLEX RECEPTACLE 20A, 125V, 3WG, NEMA 5-20R, +15" (UON). (WP=GFCI AND WEATHERPROOF WITH IN-USECOVER, D=DEDICATED)
PANEL BOARD, 120/240V, SINGLE PHASE, 3W FLUSH IN RESIDENTIAL UNITS. 120/208V 3 PHASE, 4 WIREFLUSH/SURFACE IN COMMUNITY BUILDING.
JUNCTION BOX
SECURITY CAMERA, NEW UON. REFER TO SPECIFICATOIN FOR MODEL, OR APPROVED EQUAL.
DOOR STATION WITH CONNECTED DOOR STRIKE. REFER TO SPECIFICATIONS FOR DOOR SIZING.
MASTER STATION. REFER TO SPECIFICATION FOR MODEL, OR APPROVED EQUAL.
JUNCTION OR OUTLET BOX MOUNTED ON WALL. PAINT TO MATCH MOUNTING SURFACES.
SCOPE OF WORK
A. FURNISH AND INSTALL DOOR ENTRY INTERCOM AT MAIN ENTRY AND SECOND FLOOR WITH 2 MASTER STATIONS AT MAIN OFFICE AND 1 MASTER STATION AT CAFETERIA.
B. FURNISH AND INSTALL SECURITY CAMERA SYSTEM AS INDICATED IN PLANS AND SPECS.
E0.1 ELECTRICAL TITLE SHEETE1.1 FIRST FLOOR SECURITY PLANE1.2 SECOND FLOOR SECURITY PLANE1.3 THIRD FLOOR SECURITY PLANE5.1 WIRING DIAGRAMSE6.1 DETAILS
SITE NO.
SCALE
DATECHECKED BY
S.F.U.S.D. PROJECT NO.
SHEETS
DRAFTER
OF
04/15/16FM
MISSION EDUCATION
CENTER
1670 NOE STREET
SAN FRANCISCO, CA 94131
MISSION EDUCATION
CENTER SECURITY
CAMERAS PROJECT
SH
CONSTRUCTION
DESIGN &
FACILITIES
135 Van Ness Avenue
San Francisco, California 94102
Tel (415) 355-6979
Fax (415) 355-6988
Architect Engineer
School Name and Address
Project Name
Date No. Revisions
SHEET NO.
DRAWING TITLE
Approvals
AS NOTED
SFUSD SAN FRANCISCOPUBLIC SCHOOLS
Consultant Name and Address
EDesignCIncorporatedEDesignCIncorporated
H
R
WAO
ET
EXP. 12-31-16
S
No. E18568 EERNI
GEN
S IOFESAN L
O
TAT
S
DE
ISTE
RG
RE
FOE
AINRLCA FOI
PR
LAT R CICE EL
EHP
N
TER
04/15/16 1 BID SET
11819
E0.1
WORKTABLE
34"H X
24"D X 36"L
WO
RK
TA
BL
E
34"H
X
24
"D
X
7
2"L
FE
FE
FEC
FEC
FEC
FE
FE
FE
FE
FE
S
Pump/
Tank
Disc.
Sw.
Control
S
A
DN
UPUP
UP
(E) PANEL '1B'
UP TO CCTV SERVER INMDF AT FLOOR ABOVE
FURNISH AND INSTALL JUNCTION BOX AT INSTALLATION HEIGHT OF NEW CAMBERA. ROUTE CAT6TO JUNCTION BOX USING EXISTING 3/4" CONDUIT IN CAFETERIA. SEE 2/E1.1 FOR EXISTINGCONDITION.
VERIFY LOCATION WITH OWNER PRIOR TO ROUGH-IN.
SHEET NOTES
SITE NO.
SCALE
DATECHECKED BY
S.F.U.S.D. PROJECT NO.
SHEETS
DRAFTER
OF
04/15/16FM
MISSION EDUCATION
CENTER
1670 NOE STREET
SAN FRANCISCO, CA 94131
MISSION EDUCATION
CENTER SECURITY
CAMERAS PROJECT
SH
CONSTRUCTION
DESIGN &
FACILITIES
135 Van Ness Avenue
San Francisco, California 94102
Tel (415) 355-6979
Fax (415) 355-6988
Architect Engineer
School Name and Address
Project Name
Date No. Revisions
SHEET NO.
DRAWING TITLE
Approvals
AS NOTED
SFUSD SAN FRANCISCOPUBLIC SCHOOLS
Consultant Name and Address
EDesignCIncorporatedEDesignCIncorporated
H
R
WAO
ET
EXP. 12-31-16
S
No. E18568 EERNI
GEN
S IOFESAN L
O
TAT
S
DE
ISTE
RG
RE
FOE
AINRLCA FOI
PR
LAT R CICE EL
EHP
N
TER
04/15/16 1 BID SET
11819
E1.1
SCALE: 1/8" = 1'-0"
FIRST FLOOR SECURITY PLAN1
FIRST FLOORSECURITY PLAN
NONE
EXISTING DATA CONDUIT CAFETERIA2
(E) DATA CONDUIT TO BEUSED FOR CAMERA
A. ALL CONDUIT AND WIRING SHALL HOMERUN TO ADMINISTRATION BUILDING.B. ALL CONDUITS INSTALLED SHALL BE PAINTED TO MATCH ADJACENT SURFACES.
GENERAL SECURITY NOTES
PTZ
FE
FEC
FEC
FEC
FEFE
FE FE
FEC
FEC
RESTROOM
T4
PRINCIPAL'S OFFICE
211
HALLWAY
204
ELEVATOR E1
E02
HALLWAY
212
STAIR 1
SR12
KINDERGARTEN CLASSROOM
202
CORRIDOR
200
SERVER ROOM
214
STORAGE
202A
WOMEN'S RESTROOM
T6
ELEVATOR LOBBY
215
KINDERGARTEN TOILET
T11
STORAGE
201A
STAIR 2
SR22
CLASSROOM
201
KINDERGARTEN CLASSROOM
203
STORAGE
203A
TEACHER'S LOUNGE
205
CLASSROOM
206
STORAGE
206A
CUSTODIAN
213
CLASSROOM
207
OFFICE
209
MEN'S RESTROOM
T5
STORAGE
207A
OFFICE
208
STORAGE
208A
RECEPTION
210
DN
DN
UP
DN
UP
DN
FD
FD
FD
(E) DATA RACKTO BE USED
FOR SECURITYCAMERA
EQUIPMENT
PTZ
FURNISH AND INSTALL 120V RECEPTACLE FOR PUBLIC VIEW MONITOR. COORDINATE LOCATIONWITH OWNER.
FURNISH AND INSTALL MONITOR AND JOYSTICK FOR PTZ. LOCATION TO BE IN PRINCIPAL'S OFFICE.COORDINATE LOCATION WITH OWNER.
SHEET NOTES
SITE NO.
SCALE
DATECHECKED BY
S.F.U.S.D. PROJECT NO.
SHEETS
DRAFTER
OF
04/15/16FM
MISSION EDUCATION
CENTER
1670 NOE STREET
SAN FRANCISCO, CA 94131
MISSION EDUCATION
CENTER SECURITY
CAMERAS PROJECT
SH
CONSTRUCTION
DESIGN &
FACILITIES
135 Van Ness Avenue
San Francisco, California 94102
Tel (415) 355-6979
Fax (415) 355-6988
Architect Engineer
School Name and Address
Project Name
Date No. Revisions
SHEET NO.
DRAWING TITLE
Approvals
AS NOTED
SFUSD SAN FRANCISCOPUBLIC SCHOOLS
Consultant Name and Address
EDesignCIncorporatedEDesignCIncorporated
H
R
WAO
ET
EXP. 12-31-16
S
No. E18568 EERNI
GEN
S IOFESAN L
O
TAT
S
DE
ISTE
RG
RE
FOE
AINRLCA FOI
PR
LAT R CICE EL
EHP
N
TER
04/15/16 1 BID SET
11819
E1.2
SECOND FLOORSECURITY PLAN
SCALE: 1/8" = 1'-0"
SECOND FLOOR SECURITY PLAN1
A. ALL CONDUIT AND WIRING SHALL HOMERUN TO ADMINISTRATION BUILDING.B. ALL CONDUITS INSTALLED SHALL BE PAINTED TO MATCH ADJACENT SURFACES.
GENERAL SECURITY NOTES
9'-0"
SITE NO.
SCALE
DATECHECKED BY
S.F.U.S.D. PROJECT NO.
SHEETS
DRAFTER
OF
04/15/16FM
MISSION EDUCATION
CENTER
1670 NOE STREET
SAN FRANCISCO, CA 94131
MISSION EDUCATION
CENTER SECURITY
CAMERAS PROJECT
SH
CONSTRUCTION
DESIGN &
FACILITIES
135 Van Ness Avenue
San Francisco, California 94102
Tel (415) 355-6979
Fax (415) 355-6988
Architect Engineer
School Name and Address
Project Name
Date No. Revisions
SHEET NO.
DRAWING TITLE
Approvals
AS NOTED
SFUSD SAN FRANCISCOPUBLIC SCHOOLS
Consultant Name and Address
EDesignCIncorporatedEDesignCIncorporated
H
R
WAO
ET
EXP. 12-31-16
S
No. E18568 EERNI
GEN
S IOFESAN L
O
TAT
S
DE
ISTE
RG
RE
FOE
AINRLCA FOI
PR
LAT R CICE EL
EHP
N
TER
04/15/16 1 BID SET
11819
E1.3
SCALE: 1/8" = 1'-0"
THIRD FLOOR SECURITY CAMERA PLAN1
THIRD FLOORSECURITY PLAN
A. ALL CONDUIT AND WIRING SHALL HOMERUN TO ADMINISTRATION BUILDING.B. ALL CONDUITS INSTALLED SHALL BE PAINTED TO MATCH ADJACENT SURFACES.
GENERAL SECURITY NOTES
PAINT OVER EXISTING BUILDING SIGNAGE. PAINT TO MATCH BUILDING EXTERIOR. COORDINATEWITH OWNER. SEE 2/E1.3.
SHEET NOTES
SCALE: 1/8" = 1'-0"
EXISTING SIGNAGE TO BE PAINTED2
PAINT OVER TO MATCHBUILDING EXTERIOR
SECOND FLOOR
SECURITYCAMERA SERVER
IN CLOSET ATADMINISTRATION
BUILDING
CAT 5 CABLEA.
B.
C.
2#18 THHN (POWER)
RG-59 COAXIAL CABLE
WIRING SCEDEULE
A,B (TYP EACHCAMERA)
SECURITY SYSTEM DIAGRAM NOTES:
CAMERA POWER SUPPLY
FIRST FLOOR
MONITOR ANDJOY STICK
PUBLIC MONITORC
A,C
A,B (TYP EACHCAMERA)
A,B (TYP EACHCAMERA)
NOTE: SEE FLOOR PLANS FORPATHWAYS. CONDUITS SHALL BESIZED FOR NUMBER OF CABLES INRACEWAY. 40% FILL MAXIMUM.
8 CAMERAS AT FIRST FLOOR
8 CAMERAS AT SECOND FLOOR
PTZ
RIGHT EXTERIOR STAIRS
RIGHT INTERIOR STAIRS
RIGHT EXIT
RIGHT STAIRS
TOP RIGHT CORRIDOR
LOBBY
TOP LEFT CORRIDOR
LEFT STAIRS
LEFT ENTERANCE
LEFT EXIT
RIGHT EXTERIOR CAMERA
TOP LEFT CORRIDOR
LEFT STAIRS
LEFT ENTRANCE LOBBY TOP RIGHT CORRIDOR
LEFT LOBBY
THIRD FLOOR
5 CAMERAS AT THIRD FLOOR
RIGHT CORRIDOR
LEFT CORRIDOR
RIGHTSTAIRSTOP LEFT STAIRS
A,B (TYP EACHCAMERA)
A,B (TYP EACHCAMERA)
A,B (TYP EACHCAMERA)
PTZ
LEFT EXTERIOR CAMERA
(N) CAMERAINTERCOM ATENTRY GATE
(N) ELECTRICSTRIKE
(N) POWERSUPPLY120V
MASTERSTATION
CENTRALEXCHANGE UNIT
#12
NOTE: REFER TO SPECIFICATIONSFOR WIRING REQUIREMENTS.
SCHEMATIC
SECURITY CCTV SYSTEM RISER DIAGRAM 1
SCHEMATIC
ACCESS CONTROL WIRING DIAGRAM2
WIRINGDIAGRAMS
SITE NO.
SCALE
DATECHECKED BY
S.F.U.S.D. PROJECT NO.
SHEETS
DRAFTER
OF
04/15/16FM
MISSION EDUCATION
CENTER
1670 NOE STREET
SAN FRANCISCO, CA 94131
MISSION EDUCATION
CENTER SECURITY
CAMERAS PROJECT
SH
CONSTRUCTION
DESIGN &
FACILITIES
135 Van Ness Avenue
San Francisco, California 94102
Tel (415) 355-6979
Fax (415) 355-6988
Architect Engineer
School Name and Address
Project Name
Date No. Revisions
SHEET NO.
DRAWING TITLE
Approvals
AS NOTED
SFUSD SAN FRANCISCOPUBLIC SCHOOLS
Consultant Name and Address
EDesignCIncorporatedEDesignCIncorporated
H
R
WAO
ET
EXP. 12-31-16
S
No. E18568 EERNI
GEN
S IOFESAN L
O
TAT
S
DE
ISTE
RG
RE
FOE
AINRLCA FOI
PR
LAT R CICE EL
EHP
N
TER
04/15/16 1 BID SET
11819
E5.1
*MOUNTING SIMILAR FORCORNER MOUNT BRACKET.INSTALL PER MANUFACTURER'SRECOMMENDATIONS.
<E>WOOD FRAMED WALL
34"CONDUIT
*WALL MOUNT BRACKET
PENDANT MOUNT ADAPTER
OCTAGONAL BACKBOX
MOUNTINC SCREWS PERMANUFACTURER'S RECOMMENDATICN
38"LAG SCREWS W/2-12" EMBEDMENT
2 #18 (24V)
CAT 6
NOTE1. CAMERAS AND MOUNT WEIGHT LESS THAN 64
LBS.
1"min.
FACE OF WALL SURFACE
CORE WALL AS REQUIRED TO ACCOMMODATEPIPE DIAMETER, SEE PLANS FOR SIZES. USENON-COMBUSTIBLE INSULATION AROUNDCONDUIT AT WALL PENETRATION
CONDUIT - SEE PLANS FOR DIA.
"NELSON" BRAND, 'CLK' OR APPROVED EQUALFIRE STOP CAULK
PLASTIC BUSHING AT END OFCONDUIT SLEEVE
COPPER OR FIBER CABLE(TYPICAL)
NOTE;
FIRE STOP SHALL BE INSTALLED TO ARCHIVEAPPROPRIATE FIRE RATING AS DEFINED BYARCHITECTURAL DRAWINGS AND COMPLY WITHAPPLICABLE "F" AND "T" RATINGS PER ASTM E-814.INSTALL PER MFR'S. SPECS.
<E>WOOD FRAMED WALL
34"CONDUIT
OCTAGONAL BACKBOX
MOUNTINC SCREWS PERMANUFACTURER'S RECOMMENDATICN
38"LAG SCREWS W/2-12" EMBEDMENT
1PR-18 AWG (24V)
CATEGORY 5E CABLE
NOTE1. CAMERAS AND MOUNT WEIGHT LESS THAN 64
LBS.
CAMERA DIRECTION TOBE INSTALLED PER
FLOOR PLANS.
DETAILS
SCHEMATIC
WALL MOUNTING DETAIL - FIXED PTZ CAMERA1
SCHEMATIC
CONDUIT SLEEVE WITH FIRE STOP AT RATED WALL2
SCHEMATIC
WALL MOUNTING DETAIL - FIXED CAMERA3
SITE NO.
SCALE
DATECHECKED BY
S.F.U.S.D. PROJECT NO.
SHEETS
DRAFTER
OF
04/15/16FM
MISSION EDUCATION
CENTER
1670 NOE STREET
SAN FRANCISCO, CA 94131
MISSION EDUCATION
CENTER SECURITY
CAMERAS PROJECT
SH
CONSTRUCTION
DESIGN &
FACILITIES
135 Van Ness Avenue
San Francisco, California 94102
Tel (415) 355-6979
Fax (415) 355-6988
Architect Engineer
School Name and Address
Project Name
Date No. Revisions
SHEET NO.
DRAWING TITLE
Approvals
AS NOTED
SFUSD SAN FRANCISCOPUBLIC SCHOOLS
Consultant Name and Address
EDesignCIncorporatedEDesignCIncorporated
H
R
WAO
ET
EXP. 12-31-16
S
No. E18568 EERNI
GEN
S IOFESAN L
O
TAT
S
DE
ISTE
RG
RE
FOE
AINRLCA FOI
PR
LAT R CICE EL
EHP
N
TER
04/15/16 1 BID SET
11819
E6.1