The Leader in Compliance TestingComprehensive, state-of-the-art testing services.
Locations
California Minnesota Oregon Washington
ContactTechnical excellence is our standard.
Unsurpassed customer service is our priority.
For more information, contact us!
Toll-Free: (888) 364-2378
Worldwide Accreditations
www.NWEMC.com
7/28/2019 Northwest EMC | SAR & CTI Brochure
2/2
Northwest EMC is your certication solution for yourwireless devices. Weve been designated by the FCC as aTelecommunications Certication Body (TCB), recognized by
Industry Canada as a Certication Body (CB), and validated bythe European Commission as a Conformity Assessment Body
(CAB).
SAR
RF safety is a regulatory requirement for many wireless devices.Weve expanded our testing services to include SAR (SpecicAbsorption Rate) evaluations.
Our SAR Testing lab is located in a semi-anechoic chamber tomaintain strict temperature control and eliminate inuences fromother nearby transmitters. Weve selected the premier supplierof SAR evaluation systems and government-preferred vendor,SPEAG of Zurich Switzerland, to provide their latest offering theDASY5. Equipped with probes, tissue simulants, and phantoms,the DASY5 can evaluate wireless devices operating from 400MHz 6 GHz.
In addition, we use Agilent 8960 test set to support all cellularoperating modes up through EVDO and HSPA Rel. 6. Our SARtesting is NVLAP accredited to ISO 17025 requirements.
Specic Tests Offered: OET Bulletin 65, Edition 97-01(Aug 1997); Supplement C, Edition 01-01 to OET Bulletin65, Edition 97-01; IEEE Standard 1528 (2003) includingAmndmt 1; EN 62369-1:2009; EN 50360 (2001); EN62209-1 (2006); IEC 62209-01 (Feb 2005); IEC 62209-02
(2010); ANSI C95.1:2005+ A1:2010, EN 50364 (2001); EN50371 (2002)
WIRELESS TESTINGand SAR EVALUATIONS
Notable Equipment: SPEAG DASY5 SAR test system,Agilent 8960 call box, and Agilent PNA network analyzer(20 GHz) with dielectric probe.
Devices that require SAR: System integrators andmedical device manufacturers with radios that areoperated closer than 20cm to the head or torso. Thisincludes devices that are small enough for a coat pocket,belt clip, or used on the lap like a notebook computer.
The SAR chamber is 12 ft wide by 16 ft long x 8 ft high. Adedicated HVAC unit provides +/- 1 degree C temperaturecontrol.
The SAR measurement system is located in a semi-anechoicchamber. This provides an ambient free environment that alsoeliminates reections.
Northwest EMC will bridge the gap
between your products and the world.