14
YMC GENERAL CATALOG 3 Normal-Phase Columns Types and characteristics of normal-phase columns YMC-Pack SILSIL-06 YMC-Pack CN YMC-Pack Diol-NP YMC-Pack Polyamine YMC-Pack NH2 YMC-Pack PA-G YMC-Pack PVA-Sil YMC columns for SFC separation 80,81 82,83 84,85 86,87 88,89 90 90 91 92 79 第03章.indd 79 11.1.28 10:48:55 AM

Normal-Phase Columns · YMC Co., Ltd. offers normal-phase columns packed with bare silica gel or packed with silica gel modified with polar groups. ... CH3 NO2 NH2 NO2 NH2 NO2 NH2

Embed Size (px)

Citation preview

YMC GENERAL CATALOG

3Normal-Phase Columns

Types and characteristics ofnormal-phase columns

YMC-Pack SIL、SIL-06YMC-Pack CNYMC-Pack Diol-NPYMC-Pack Polyamine ⅡYMC-Pack NH2

YMC-Pack PA-GYMC-Pack PVA-SilYMC columns for SFC separation

80,81

82,8384,8586,8788,89

90909192

79

第03章.indd 79 11.1.28 10:48:55 AM

80

3

Norm

al-Phase C

olumns

Types and characteristics of normal-phase columns

Product NamePore size(Å)

Particlesize

(µm)

Usable pH range Characteristics Page

YMC-Pack seriesSIL 120

3

2.0 ~ 7.5

・ Standard normal-phase column using non-polar mobile phase

・ For separation of various isomers and compounds with similar structures

82,835

10

SIL-06 60 510

CN 1205 ・ For normal-phase separation using non-polar mobile phase similar to that used with silica gel

・ Can be used in reversed-phase mode using aqueous mobile phase 84,8510

Diol-NP60

5・ For normal-phase separation using non-polar mobile phase・ Different separation characteristics from bare silica gel・ Useful for normal-phase separation (HILIC) of hydrophilic compounds

86,87120

Polyamine Ⅱ 120 5 ・ For normal-phase separation using non-polar mobile phase・ For separation of sugars and vitamins using aqueous mobile phase 88,89

NH2 120 5 ・ For normal-phase separation using non-polar mobile phase・ For separation of sugars using aqueous mobile phase 90

PA-G 120 5 4.0 ~ 7.5 ・ For separation of sugars using aqueous mobile phase 90

PVA-Sil 120 5 2.0 ~ 9.5 ・ Silica gel chemically bonded with polyvinyl alcohol・ Excellent for supercritical fluid chromatography 91

Selection of YMC-Pack CN separation modes

10 20 min

1

2

3

4

0

(S930322B)

Reversed-phase mode

Column :YMC-PackCN(5µm,120Å)250×4.6mmI.D.

Eluent :acetonitrile/water(40/60)Flowrate :0.6mL/minPressure :5.6MPaTemperature:30℃Detection :UVat254nm,0.32AUFSInjection :3µL(0.25mg/mL)

1

2

3

4

10 20 min0

(S930319D)

Normal-phase mode

Column :YMC-PackCN(5µm,120Å) 250×4.6mmI.D.

Eluent :hexane/methanol/dichloromethane(75/20/5)Flowrate :0.6mL/minPressure :2.6MPaTemperature:30℃Detection :UVat254nm,0.32AUFSInjection :3µL(0.25mg/mL)

AnexampleofanalysisusingYMC-PackCNinwhichthesamesamplesareanalyzedinbothnormal-phaseandreversed-phasemodes,isshownontheleft.YMC-PackCNcanbeusedinbothnormal-phaseandreversed-phasemodes,sinceithascyanopropylgroupsofmediumpolarity.Itcanbeusedinreversed-phasemodewithaqueousmobilephaseofhigherpolaritythanthestationaryphase.Itcanalsobeusedinnormal-phasemodewithlow-polaritymobilephasesuchashexane.Theorderofelutionwillbereverseddependingontheseparationmode.

4.

O

CH 3

O

3.

O

CH OH2

O

2.

O

CH OH

HO

2

O

1.

O

CH OH

OHHO

2

O

Progesterone

Deoxycorticosterone

Corticosterone

Hydrocortisone

High

Polarity

Low

Types and characteristics of normal-phase columnsNormal-phase chromatography is useful for the separation of positional isomers that are difficult to separate in reversed-phase mode.YMC Co., Ltd. offers normal-phase columns packed with bare silica gel or packed with silica gel modified with polar groups.

第03章.indd 80 11.1.28 10:48:58 AM

81

3

Norm

al-Phase C

olumns

Separation characteristics of normal-phase columns

5 10 15 200 min

1

2

3

4

(A010606A)

YMC-Pack SIL(5 µm, 120 Å)

�1.�Di-n-octyl�phthalate2.�Di-n-butyl�phthalate3.�Diethyl�phthalate4.�Dimethyl�phthalate

Silica gel

Acomparisonofelutionbehaviorofvariousnormal-phasecolumnsinseparationofphthalateestersisshown.Generally,innormal-phasechromatography,thehigherthepolarityofthestationaryphasesurface,thegreatertheretentionofsolutes.Thepolarityofchemicallybondedpackingmaterialsislowerthanthatofsilicagelandthesepackingmaterialshavedifferentseparationcharacteristics.

Chemically bonded packing material

1

2 3

4

YMC-Pack Polyamine Ⅱ(5 µm, 120 Å)

5 10 150 min(A010607A)

1

2

34

YMC-Pack Diol-NP(5 µm, 120 Å)

5 100 min(A010606G)

1

2

3

4

YMC-Pack CN(5 µm, 120 Å)

5 100 min(A010606C)

Column :250×4.6mmI.D.Eluent :hexane/ethylacetate(90/10)Flowrate :1.0mL/minTemperature:30℃Detection :UVat254nm

第03章.indd 81 11.1.28 10:49:01 AM

82

3

Norm

al-Phase C

olumns

Analytical columns

YMC-Pack SIL, YMC-Pack SIL-06● High quality spherical porous silica gel● Normal-phase separation due to surface silanol groups● Two different pore sizes are available● Useful for separation of compounds with similar structures

S t a n d a r d n o r m a l - p h a s e c o l u m nYMC-PackSILissuitableforseparationoffat-solublecompoundsusingnon-polarmobilephaseandseparationofpositionalisomersthataredifficulttoseparateinreversed-phasemode.SIL-06(porediameter60Å)hasgreaterabsorptionpropertiesthanSIL-12(porediameter120Å)duetoitslargerspecificsurfacearea,andis

generallyusefulforseparatingnaturalproductswithalowmolecularweight.Althoughwateroraceticacidcanbeusedasanadditivetothemobilephase,theyarelikelytobindtosilanol.Inconsiderationofseparationreproducibility,itispreferabletohaveonecolumndedicatedtothemobilephasecontainingwateroraceticacid.

■Poresize:60Å,120Å■UsablepHrange:2.0〜 7.5

1

2

3 4

10 min0

Tocopherol isomers1.�α-Tocopherol2.�β-Tocopherol3.�γ-Tocopherol4.�σ-Tocopherol

Column :YMC-PackSIL(5µm,120Å) 150×4.6mmI.D.

Eluent :hexane/THF/aceticacid(97/3/0.25)Flowrate :1.0mL/minTemperature:30℃Detection :UVat295nm

100 20

1

2

min

Hydrocortisone and prednisone

O

O

Prednisone

1.

3CH

3CH

2CH

C=O

OH

OH

O

HO

Hydrocortisone

2.

3CH

3CH

2CH

C=O

OH

OH

Column :YMC-PackSIL(5µm,120Å) 150×4.6mmI.D.

Eluent :chloroform/2-propanol/aceticacid(95/5/1)

Flowrate :1.0mL/minTemperature:30℃Detection :UVat250nm

A p p l i c a t i o n (G910523S)

A p p l i c a t i o n (K940530C)

第03章.indd 82 11.1.28 10:49:02 AM

83

3

Norm

al-Phase C

olumns

SIL(Pore size 120 Å)

Analytical columnsParticle size(µm)

Pore size(Å)

Column sizeinnerdiameter×length(mm) Product number

S-3 120 4.6×100 SL12S03-1046WT4.6×150 SL12S03-1546WT6.0×100 SL12S03-1006WT6.0×150 SL12S03-1506WT

S-5 120 4.6×100 SL12S05-1046WT4.6×150 SL12S05-1546WT4.6×250 SL12S05-2546WT4.6×300 SL12S05-3046WT6.0×100 SL12S05-1006WT6.0×150 SL12S05-1506WT6.0×250 SL12S05-2506WT6.0×300 SL12S05-3006WT

S-10 120 4.6×100 SL12S11-1046WT4.6×150 SL12S11-1546WT4.6×250 SL12S11-2546WT4.6×300 SL12S11-3046WT6.0×100 SL12S11-1006WT6.0×150 SL12S11-1506WT6.0×250 SL12S11-2506WT6.0×300 SL12S11-3006WT

Semi-preparative columnsParticle size(µm)

Pore size(Å)

Column sizeinnerdiameter×length(mm) Product number

S-5 120 10×150 SL12S05-1510WT10×250 SL12S05-2510WT10×300 SL12S05-3010WT20×100 SL12S05-1020WT20×150 SL12S05-1520WT20×250 SL12S05-2520WT

S-10 120 10×150 SL12S11-1510WT10×250 SL12S11-2510WT10×300 SL12S11-3010WT20×150 SL12S11-1520WT20×250 SL12S11-2520WT

SeeP152forpreparativecolumnsotherthanthoselistedabove.

Guard cartridge columns (3/pack)S-5 120 4.0×23 SL12S05-G304CC

Acartridgeholderwillneedtobepurchasedseparatelybeforeusingthisproductforthefirsttime.

Cartridge holderCartridge holder(inner diameter: 4.0 mm)

XPCHW

Guard columnsParticle size(µm)

Pore size(Å)

Column sizeinnerdiameter×length(mm) Product number

S-3 120 4.0×10 SL12S03-0104WFG5.0×10 SL12S03-0105WFG

S-5 120 4.0×10 SL12S05-0104WFG5.0×10 SL12S05-0105WFG10×30 SL12S05-0310WTG20×50 SL12S05-0520WTG

S-10 120 4.0×10 SL12S11-0104WFG5.0×10 SL12S11-0105WFG10×30 SL12S11-0310WTG20×50 SL12S11-0520WTG

SIL-06(Pore size 60 Å)

Analytical columnsParticle size(µm)

Pore size(Å)

Column sizeinnerdiameter×length(mm) Product number

S-5 60 4.6×100 SL06S05-1046WT4.6×150 SL06S05-1546WT4.6×250 SL06S05-2546WT4.6×300 SL06S05-3046WT6.0×100 SL06S05-1006WT6.0×150 SL06S05-1506WT6.0×250 SL06S05-2506WT6.0×300 SL06S05-3006WT

S-10 60 4.6×100 SL06S11-1046WT4.6×150 SL06S11-1546WT4.6×250 SL06S11-2546WT4.6×300 SL06S11-3046WT6.0×100 SL06S11-1006WT6.0×150 SL06S11-1506WT6.0×250 SL06S11-2506WT6.0×300 SL06S11-3006WT

Semi-preparative columnsParticle size(µm)

Pore size(Å)

Column sizeinnerdiameter×length(mm) Product number

S-5 60 10×150 SL06S05-1510WT10×250 SL06S05-2510WT10×300 SL06S05-3010WT20×100 SL06S05-1020WT20×150 SL06S05-1520WT20×250 SL06S05-2520WT

S-10 60 10×150 SL06S11-1510WT10×250 SL06S11-2510WT10×300 SL06S11-3010WT20×150 SL06S11-1520WT20×250 SL06S11-2520WT

SeeP152forpreparativecolumnsotherthanthoselistedabove.

Guard cartridge columns (3/pack)S-5 60 4.0×23 SL06S05-G304CC

Acartridgeholderwillneedtobepurchasedseparatelybeforeusingthisproductforthefirsttime.

Cartridge holderCartridge holder(inner diameter: 4.0 mm)

XPCHW

Guard columnsParticle size(µm)

Pore size(Å)

Column sizeinnerdiameter×length(mm) Product number

S-5 60 4.0×10 SL06S05-0104WFG5.0×10 SL06S05-0105WFG10×30 SL06S05-0310WTG20×50 SL06S05-0520WTG

S-10 60 4.0×10 SL06S11-0104WFG5.0×10 SL06S11-0105WFG10×30 SL06S11-0310WTG20×50 SL06S11-0520WTG

Ordering information

第03章.indd 83 11.1.28 10:49:03 AM

84

3

Norm

al-Phase C

olumns

Analytical columns

YMC-Pack CN● Silica gel chemically bonded with cyanopropyl groups● For both normal-phase and reversed-phase modes● Different separation characteristics from bare silica gel● Faster column equilibration than bare silica gel

Column can be used in both normal -phase and reversed-phase modesYMC-PackCNshowsretentionbehaviorofnormal-phasechromatographywhenitisusedwithlow-polaritymobilephasessuchashexane.SinceYMC-PackCNstationaryphasesurfaceislesspolarthanbaresilicagel,theretentiontimesofanalytesaregenerallyshorterthanwithbaresilicagel.YMC-PackCNisthereforeappropriateforsampleshavingtoostrongretentionwhen

analyzedusingbaresilicagel.Incontrast,YMC-PackCNshowsretentionbehaviorofreversed-phasechromatographywhenitisusedwithhighpolaritymobilephase,suchasmethanolandwater.Althoughseparationmodesareselectableaccordingtothepurposeofseparation,itispreferabletouseonecolumndedicatedforoneseparationmodeinconsiderationofthelifeofthecolumn.

■Poresize:120Å■UsablepHrange:2.0〜 7.5

1

2

3

4 5

10 200 min

Nitroaniline isomers1. 2. 3. 4. 5.

CH3 NO2 NH2NO2

NH2

NO2

NH2

NO2Toluene Nitrobenzene o-Nitroaniline m-Nitroaniline p-Nitroaniline

Column :YMC-PackCN(5µm,120Å) 250×4.6mmI.D.

Eluent :hexane/2-propanol(80/20)Flowrate :1.0mL/minTemperature:30℃Detection :UVat254nm

A p p l i c a t i o n (A010619A)

Analytical columnsParticle size(µm)

Pore size(Å)

Column sizeinnerdiameter×length(mm) Product number

S-3 120 2.0× 35 CN12S03-H502WT2.0× 50 CN12S03-0502WT2.0× 75 CN12S03-L502WT2.0×100 CN12S03-1002WT2.0×150 CN12S03-1502WT3.0× 50 CN12S03-0503WT3.0×100 CN12S03-1003WT3.0×150 CN12S03-1503WT4.6×100 CN12S03-1046WT4.6×150 CN12S03-1546WT

S-5 120 1.0×150 CN12S05-1501WT1.0×250 CN12S05-2501WT1.5×150 CN12S05-15P5WT1.5×250 CN12S05-25P5WT2.0×150 CN12S05-1502WT2.0×250 CN12S05-2502WT4.6× 75 CN12S05-L546WT4.6×100 CN12S05-1046WT4.6×150 CN12S05-1546WT4.6×250 CN12S05-2546WT4.6×300 CN12S05-3046WT6.0×100 CN12S05-1006WT6.0×150 CN12S05-1506WT6.0×250 CN12S05-2506WT6.0×300 CN12S05-3006WT

Particle size(µm)

Pore size(Å)

Column sizeinnerdiameter×length(mm) Product number

S-5 300 1.0×150 CN30S05-1501WT1.0×250 CN30S05-2501WT1.5×150 CN30S05-15P5WT1.5×250 CN30S05-25P5WT2.0×150 CN30S05-1502WT2.0×250 CN30S05-2502WT4.6× 75 CN30S05-L546WT4.6×100 CN30S05-1046WT4.6×150 CN30S05-1546WT4.6×250 CN30S05-2546WT4.6×300 CN30S05-3046WT6.0×100 CN30S05-1006WT6.0×150 CN30S05-1506WT6.0×250 CN30S05-2506WT6.0×300 CN30S05-3006WT

S-10 120 4.6×100 CN12S11-1046WT4.6×150 CN12S11-1546WT4.6×250 CN12S11-2546WT4.6×300 CN12S11-3046WT6.0×100 CN12S11-1006WT6.0×150 CN12S11-1506WT6.0×250 CN12S11-2506WT6.0×300 CN12S11-3006WT

*ShippingsolventforCNismethanol/water(60/40).Pleasetakecareofmiscibilityinnormal-phaseseparation.

Ordering information

第03章.indd 84 11.1.28 10:49:05 AM

85

3

Norm

al-Phase C

olumns

Semi-preparative columnsParticle size(µm)

Pore size(Å)

Column sizeinnerdiameter×length(mm) Product number

S-5 120 10×150 CN12S05-1510WT10×250 CN12S05-2510WT10×300 CN12S05-3010WT20×100 CN12S05-1020WT20×150 CN12S05-1520WT20×250 CN12S05-2520WT

300 20×150 CN30S05-1520WT20×250 CN30S05-2520WT

S-10 120 10×150 CN12S11-1510WT10×250 CN12S11-2510WT10×300 CN12S11-3010WT20×150 CN12S11-1520WT20×250 CN12S11-2520WT

SeeP151forpreparativecolumnsotherthanthoselistedabove.

Guard cartridge columns (with inner diameter 1.0, 1.5, or 2.0 mm: 2/pack, 4.0 mm: 3/pack)S-3 120 2.0×10 CN12S03-0102CC

4.0×23 CN12S03-G304CC

S-5 120 1.0×10 CN12S05-0101CC1.5×10 CN12S05-01P5CC2.0×10 CN12S05-0102CC4.0×23 CN12S05-G304CC

300 1.0×10 CN30S05-0101CC1.5×10 CN30S05-01P5CC2.0×10 CN30S05-0102CC4.0×23 CN30S05-G304CC

Acartridgeholderwillneedtobepurchasedseparatelybeforeusingthisproductforthefirsttime.

Cartridge holderSemi-micro guard cartridge holder(inner diameter: 1.0, 1.5, or 2.0 mm)

XPCHSMW

Cartridge holder(inner diameter: 4.0 mm)

XPCHW

Guard columnsParticle size(µm)

Pore size(Å)

Column sizeinnerdiameter×length(mm) Product number

S-5 120 4.0×10 CN12S05-0104WFG5.0×10 CN12S05-0105WFG10×30 CN12S05-0310WTG20×50 CN12S05-0520WTG

300 4.0×10 CN30S05-0104WFG5.0×10 CN30S05-0105WFG10×30 CN30S05-0310WTG20×50 CN30S05-0520WTG

S-10 120 4.0×10 CN12S11-0104WFG5.0×10 CN12S11-0105WFG10×30 CN12S11-0310WTG20×50 CN12S11-0520WTG

*ShippingsolventforCNismethanol/water(60/40).Pleasetakecareofmiscibilityinnormal-phaseseparation.

Ordering information

第03章.indd 85 11.1.28 10:49:05 AM

86

3

Norm

al-Phase C

olumns

Analytical columns

YMC-Pack Diol-NP● Silica gel bonded with dihydroxypropyl group● Two pore sizes of 120 Å and 60 Å are available● Normal-phase separation using non-polar

solvents

● Useful for hydrophilic interaction chromatography (HILIC)

● Different separation characteristics from bare silica gel

D i f f e r e n t s e p a r a t i o n c h a r a c t e r i s t i c s f r o m b a r e s i l i c a g e lYMC-PackDiol-NPshowsretentionbehaviorofnormal-phasechromatographywhenitisusedwithlow-polaritymobilephases.Hydroxylgroupsonthesurfaceofthestationaryphaseactaspolargroups.YMC-PackDiol-NPisaswidely

applicabletonormal-phaseseparationassilicagel.Itisalsousefulincaseswhereseparationoptimizationisdifficulttoachieveusingbaresilicagel.Inaddition,itisavailableforHILICmodeseparationbyusingorganic/watermobilephases.

■Poresize:120Å,60Å■UsablepHrange:2.0〜 7.5

Separation characteristics of Diol-NP and SIL

5 10 15 200 minA010526A

1

2

3

4

5 6

YMC-Pack Diol-NP(5 µm, 120 Å)

5 10 150 minA010526C

1

23

4

5

6YMC-Pack SIL(5 µm, 120 Å)

Column :250×4.6mmI.D.Eluent :hexane/ethanol(80/20)Flowrate :1.0mL/minTemperature:30℃Detection :UVat254nm

DifferencesinseparationcharacteristicsofDiol-NPandSILforseparatingphenolsareshownontheleft.Diol-NPshowslongerretentionandbetterseparationthanSILinseparatingthesecompounds.

OH

OHOH

OH

HO

OH

HO

HO

OH

OH

OH

HO OH

Phenol

1.

2.

Catechol

3.

Resorcinol

4.

Hydroquinone

5.

Pyrogallol

6.

Phloroglucinol

Available as a HILIC column for separation of hydrophilic compounds

1

5

4

32

6

0 105 min15R090116P

Diol-NPisavailableforHILICmodeseparationbyusingorganic/watermobilephases.

1. Uracil 2. Uridine 3. Adenosine 4. Cytosine 5. Cytidine 6. Guanosine

NH

HN

O

O

N

HN

OH

O

OH

HOH2CO

O

N

N

N

N

OH

O

OH

HOH2C

NH2

NH

N

O

NH2

N

N

OH

O

OH

HOH2CO

NH2

HN

N

N

N

O

OH

O

OH

HOH2CH2N

Column :YMC-PackDiol-NP(5µm,120Å)150×2.0mmI.D.

Eluent :water/acetonitrile(10/90)containing10mMCH3COONH4Flowrate :0.2mL/minTemperature:30℃Detection :UVat254nm

第03章.indd 86 11.1.28 10:49:10 AM

87

3

Norm

al-Phase C

olumns

Analytical columnsPacking material

Particle size(µm)

Pore size(Å)

Column sizeinnerdiameter×length(mm) Product number

Diol-60 S-5 60 3.0×150 DN06S05-1503WT4.6×100 DN06S05-1046WT4.6×150 DN06S05-1546WT4.6×250 DN06S05-2546WT

Diol-120 S-5 120 2.0×150 DN12S05-1502WT3.0×150 DN12S05-1503WT4.6× 50 DN12S05-0546WT4.6×100 DN12S05-1046WT4.6×150 DN12S05-1546WT4.6×250 DN12S05-2546WT

Semi-preparative columnsPacking material

Particle size(µm)

Pore size(Å)

Column sizeinnerdiameter×length(mm) Product number

Diol-60 S-5 60 20×150 DN06S05-1520WT20×250 DN06S05-2520WT

Diol-120 S-5 120 20×150 DN12S05-1520WT20×250 DN12S05-2520WT

*ShippingsolventforDiol-NPishexane/2-propanol(99.5/0.5).Incaseofusingeluentincludingwater,takecareofmiscibility.

N

N N

NH2

NH2

H2N

Melamine

1.Analysis of melamine in powdered cheese

(R090127P)

(R090127Q)

(R090127R)

A) Powdered cheese (blank)

C) Standard (0.5 µg/mL)

B) Melamine-spiked powdered cheese (10 mg/kg, final 0.5 µg/mL)

Powdered cheese (1 g)50% aqueous acetonitrile (5 mL)

Sonication for 30 min

Centrifugation (10,000 rpm) for 10 min

Filtration with YMC Duo-Filter (0.2 µm)

Filtration with YMC Duo-Filter (0.2 µm)

Dilution with acetonitrile or eluent

Analysis by HPLC

Extraction procedures for melamineExtraction procedures for melamine

0

60

80

40

20

mAU

min

1

1

0 4321 5

Excellent reproducibility and durability

Theabovedatashowsanalysisofmelamineinpowderedcheese,includinglot-to-lotreproducibilityandrepeatability(durability).Ingeneral,HILICcolumntendstoshowlessreproducibilityordurabilitybutDiol-NPshowsverygoodperformance.HILICcolumnlikebaresilica,zwitterionandaminotypemayadsorbioniccompounds,ontheotherhandDiol-NPhasneutralfunctionalgroupswhichreducenonspecificadsorptions.Therefore,itwouldresultinshowinggoodreproducibilityanddurability.

Lot-to-lot reproducibility

(R090625B)

(R090702A)

(R090625H)

Lot. A

Lot. C

Lot. B

Melamine

min

mAU

0

75

50

25

0 321 4

Repeatability (durability)

(R090129K)(R090129K)

(R090129G)(R090129G)

(R090129H)

(R090129I)

(R090129J)

(R090129F)(R090129F)

0 4 5321 min

1st

200th300th400th500th

100th0

100

600

500

400

300

200

mAU

Melamine

Column :YMC-PackDiol-NP(5µm,120Å)150×2.0mmI.D.

Eluent :10mMCH3COONH4/methanol(5/95)Flowrate :0.2mL/minTemperature:40℃Detection :UVat210nm

Ordering information

第03章.indd 87 11.1.28 10:49:25 AM

88

3

Norm

al-Phase C

olumns

Analytical columns

YMC-Pack Polyamine Ⅱ● Silica gel chemically bonded with polyamine● The most suitable column for separation of sugars● Solves durability problem of conventional

silica-based amino columns

● Useful for separation of hydrophilic compounds including vitamins

● Useful for separation of fat-soluble compounds using nonaqueous mobile phase

A m i n o c o l u m n w i t h i m p r o v e d d u r a b i l i t yYMC-PackPolyamineIIisasilica-basedpackingbondedwithpolyamine.Itisparticularlyusefulforseparationofsugars.ThecolumnlifetimeofYMC-PackPolyamineⅡinaqueousmobilephaseislongerthanconventionalsilica-basedaminocolumns,andthusis

applicabletoseparationofoligosaccharidesusingmobilephasewithrelativelyhigherwatercontent.Inaddition,YMC-PackPolyamineⅡcanbeusedtoseparateioniccompoundswithacombinationofnormal-phasemodeandweakanionexchangemode.

■Poresize:120Å■UsablepHrange:2.0〜 7.5

Excellent durability

0 50 100

10

20

30

Fructose

Glucose

Sucrose

Maltose

Lactose

Continuous flow of water (time, hr)

Retention time (min) 〈Flowconditions〉

Column :YMC-PackPolyamineⅡ 250×4.6mmI.D.

Eluent :waterFlowrate :1.0mL/minTemperature:ambientTime :100hours

〈Analyticalconditions〉Eluent :acetonitrile/water(75/25)Flowrate :1.0mL/minTemperature:26℃Detection :RI,32×10-6RIU/FS

Eveninahardflowdurabilitytestusingamobilephasethatconsistsonlyofwater,theretentiontimeofsugarschangeslittle.

The most suitable column for separation of sugars, including oligosaccharides

10 20 30 40 min0

1 2

3

45

1. Maltoundecaose(G11)2. Maltododecaose(G12)3. Maltotridecaose(G13)4. Maltotetradecaose(G14)5. Maltopentadecaose(G15)

(T910718A)

Column :YMC-PackPolyamineⅡ 250×4.6mmI.D.Eluent :acetonitrile/water(55/45)Flowrate :1.0mL/minTemperature:26℃Detection :RI,32×10-6RIU/FS

1

23

45

1. Fructose2. Glucose3. Sucrose4. Maltose5. Lactose

(F030618H)10 20 30 min0

Column :YMC-PackPolyamineⅡ 250×4.6mmI.D.Eluent :acetonitrile/water(75/25)Flowrate :1.0mL/minTemperature:25℃Detection :RI,32×10-6RIU/FS

第03章.indd 88 11.1.28 10:49:28 AM

89

3

Norm

al-Phase C

olumns

Elution volume of sugars and sugar alcohols

0

5

10

15

20

25

30

35

40

45

50

55

60

65

Glycerol

ErythritolFucose

Xylose

Xylitol

Rhamnose

Arabitol

Frucutose

Mannose(※)

Sorbitol

Mannitol

Glucose

Galactose(※)

Sucrose

Inositol

Maltitol

Maltose

Lactose

Raffinose

Palatinose

Sucralose

Ribitol

75% 80% 85%

Lactitol

Palatinit

Acetonitrile concentration (%)※Not detected with 85% acetonitrile

Elution volume (mL)

YMC-PackPolyamineⅡisapplicableforseparationoffat-solublevitaminsandwater-solublevitaminsasanormal-phasecolumnthatcanbeusedwithwaterorbufferandvariousorganicsolvents.

For normal-phase separation

10

1

2

3

4

0 20 30 min (T920728E)

O

CH

HO

H C

3

CH 3

3

α-Tocopherol

1.

O

HO

H C

CH 3

3

γ-Tocopherol

3.

O

CH

HO3

CH 3

β-Tocopherol

2.

O

HO

CH 3

σ-Tocopherol

4.

Column :

Eluent :

Flow rate :Temperature :Detection :

YMC-Pack Polyamine Ⅱ250×4.6 mmI.D.hexane/ethly acetate(70/30)1.0 mL/min30 ℃UV at 295 nm

Tocopherol isomers

(A970603A)min

1

2 3

0 10 20

1. Nicotinic acid2. Erythorbic acid3. L-Ascorbic acid

Column :

Eluent :Flow rate :Temperature :Detection :

YMC-Pack Polyamine Ⅱ250×4.6 mmI.D.acetonitrile/50 mM NH4H2PO4 (70/30)1.0 mL/min30 ℃UV at 250 nm

Water-soluble vitamin

Analytical columnsParticle size(µm)

Pore size(Å)

Column sizeinnerdiameter×length(mm) Product number

S-5 120 4.6×150 PB12S05-1546WT4.6×250 PB12S05-2546WT6.0×150 PB12S05-1506WT6.0×250 PB12S05-2506WT

Semi-preparative columnsParticle size(µm)

Pore size(Å)

Column sizeinnerdiameter×length(mm) Product number

S-5 120 10×250 PB12S05-2510WT20×250 PB12S05-2520WT

Guard cartridge columns (three-pack)S-5 120 4.0×23 PB12S05-G304CC

Acartridgeholderwillneedtobepurchasedseparatelybeforeusingthisproductforthefirsttime.

Cartridge holderCartridge holder(inner diameter: 4.0 mm)

XPCHW

Guard columnsS-5 120 4.0×10 PB12S05-0104WFG

5.0×10 PB12S05-0105WFG10×30 PB12S05-0310WTG20×50 PB12S05-0520WTG

Ordering information

第03章.indd 89 11.1.28 10:49:31 AM

90

3

Norm

al-Phase C

olumns

Analytical columns

YMC-Pack NH2

● Silica gel chemically bonded with aminopropyl groups● Useful for separation of sugars● Enables normal-phase mode separation using aqueous or nonaqueous mobile phase

N o r m a l - p h a s e s e p a r a t i o n c o l u m n u t i l i z i n g a m i n o g r o u p sYMC-PackNH2isanormal-phaseseparationcolumnutilizingthepolarityofprimaryaminogroups.Itisalso

applicabletoseparationsutilizingweakanionexchange.YMC-PackNH2isoftenusedforseparationofsugars.

■Poresize:120Å■UsablepHrange:2.0〜 7.5

YMC-Pack PA-G● Silica gel chemically bonded with polyamine● Useful for separation of acidic oligosaccharides

N o r m a l - p h a s e s e p a r a t i o n c o l u m n u t i l i z i n g a m i n o g r o u p sYMC-PackPA-Gisusefulforseparationofacidicoligosaccharides.YMC-PackPA-GissimilarselectivityasYMC-PackPA.

■Poresize:120Å■UsablepHrange:4.0〜 7.5

Analytical columnsParticle size(µm)

Pore size(Å)

Column sizeinnerdiameter×length(mm) Product number

S-5 120 4.6×100 NH12S05-1046WT4.6×150 NH12S05-1546WT4.6×250 NH12S05-2546WT4.6×300 NH12S05-3046WT6.0×100 NH12S05-1006WT6.0×150 NH12S05-1506WT6.0×250 NH12S05-2506WT6.0×300 NH12S05-3006WT

Semi-preparative columnsS-5 120 10×150 NH12S05-1510WT

10×250 NH12S05-2510WT10×300 NH12S05-3010WT20×150 NH12S05-1520WT20×250 NH12S05-2520WT

SeeP153forpreparativecolumnsotherthanthoselistedabove.

Guard cartridge columns (three-pack)Particle size(µm)

Pore size(Å)

Column sizeinnerdiameter×length(mm) Product number

S-5 120 4.0×23 NH12S05-G304CC

Acartridgeholderwillneedtobepurchasedseparatelybeforeusingthisproductforthefirsttime.

Cartridge holderCartridge holder(inner diameter: 4.0 mm)

XPCHW

Guard columnsParticle size(µm)

Pore size(Å)

Column sizeinnerdiameter×length(mm) Product number

S-5 120 4.0×10 NH12S05-0104WFG5.0×10 NH12S05-0105WFG10×30 NH12S05-0310WTG20×50 NH12S05-0520WTG

Ordering information

Analytical columnsParticle size(µm)

Pore size(Å)

Column sizeinnerdiameter×length(mm) Product number

S-5 120 4.6×150 PG12S05-1546WT4.6×250 PG12S05-2546WT

Ordering information

Guard columnsS-5 120 4.0× 10 PG12S05-0104WFG

第03章.indd 90 11.1.28 10:49:32 AM

3

Norm

al-Phase C

olumns

91

Analytical columns

YMC-Pack PVA-Sil● Vinyl alcohol polymerised silica● High stability and reproducibility● Excellent choice for SFC (Supercritical Fluid Chromatography)

P o l y v i n y l a l c o h o l f u n c t i o n a l i z e d s i l i c aYMC-PackPVA-Sil,bondedwithamonomolecularpolymercoatingofvinylalcohol(PVA),completelycoversbothexternalandinternalsurfacesofthesilicasupport,protectingitagainstaggressive,highpHbuffersand

solvents.ThePVApolymershellonPVA-Sildeactivatesthesilicasupportwhileprovidingahydrophilicsurface.PVA-SilcolumnarealsowellsuitedforSFCseparations.(seepage92forSFC.)

■Poresize:120Å■UsablepHrange:2.0〜 9.5■RecommendedpHrange:2.0〜 7.5

0

Time (min)

SE

S ASG

DG MGDGDGDG

PE

PG PI

PC

SGCER

? ?

8 16 24 32 40

Potato Lipids

Column :YMC-PackPVA-Sil(5µm,120Å),250×4.6mmI.D.Flowrate :1to2mL/minMobilePhase:A)2-methylpentane/methyltert-butylether(98/2)

B)2-propanol/acetonitrile/CHCI3/CH3COOH(84/8/8/0.025)C)2-propanol/water/triethylamine(50/50/0.2)

Gradient Tmin:0 5 15 40 40.1 45 50 B%:0 20 52 52 70 0 0 C%:0 0 4 14 0 0 0 Flow(mL/min):1 1 1 1.4 1.4 2 2

Nebulisertemperature:25℃,Evaporationtemperature:35℃Detector:ELSDSampleS:Sterols CER:CerebrosidesSE:SterolEsters SG:SterylglycosidesMGDG:Monogalactosyldiacylglycerols DGDG:DigalactosyldiacylglycerolsPE:Phosphatidylethanolamine PG:PhosphatidylglycerolsPC:Phosphatidylcholine ASG:AcylsterylglycosidesPI:Phosphatidylinositol DG:Diacylglycerol

A p p l i c a t i o n Literature:W.W.Christie;R.A.Urwin,J.HighResol.Chromatogr.,Vol.18(1995)P97-100

0 5 10 15 20 min

0

5

10

15

20

25mAU

1

23

4

5

6

Nucleotides (in HILIC mode)1.�5'-TMP2.�5'-UMP3.�5'-IMP4.�5'-AMP5.�5'-GMP6.�5'-CMP

Column :YMC-PackPVA-Sil(5µm,120Å)150×2.0mmI.D.

Eluent :acetonitrile/100mMCH3COONH4(75/25)Flowrate :0.2mL/minTemperature:40℃Detection :UVat254nm

A p p l i c a t i o n (R100208K)

Ordering information

Analytical columnsParticle size(µm)

Pore size(Å)

Column sizeinnerdiameter×length(mm) Product number

S-5 120 4.6× 50 PV12S05-0546WT4.6×100 PV12S05-1046WT4.6×150 PV12S05-1546WT4.6×250 PV12S05-2546WT

Guard cartridge columns (three-pack) S-5 120 4.0×23 PV12S05-G304CC

Acartridgeholderwillneedtobepurchasedseparatelybeforeusingthisproductforthefirsttime.

Cartridge holderCartridge holder(inner diameter:4.0 mm)

XPCHW

第03章.indd 91 11.1.28 10:49:36 AM

92

3

Norm

al-Phase C

olumns

Analytical columns

YMC columns for SFC separation● 11 Selectivity Options● Quality Control via SFC evaluation● Below columns stocked for immediate

delivery

● 3 µm also available● Please inquire for preparative

versions and additional analytical configurations

Efficient separation of achiral APIs (Active Pharmaceutical Ingredients) in SFC modeInrecentyears,SFChasgainedenormouslyinimportanceandacceptanceinthepharmaceuticalindustry.Nowadays,itisroutinelyusedforthepurificationofenantiomers.Inaddition,SFChasassumedarelevantrolebothinanalyticalseparationsandlargerscalepurificationofachiralcompounds

asitisseenasaneconomicand"green"alternativetoclassicalHPLC.WehaveabundantpackingmaterialsforachiralSFCseparations.InabroadrangeofdifferentSFCselectivitythatcansolvethemostdiverseseparationproblems.

Packing material

Particle size(µm)

Pore size(Å)

Column sizeinnerdiameter×length(mm) Product number

2-ethyl pyridine S-5 60 4.6×250 EP06S05-2546PS

Diol S-5 60 4.6×250 DP06S05-2546PS

120 4.6×250 DL12S05-2546PS

diethylaminopropyl S-5 60 4.6×250 DE06S05-2546PS

pyridine amide S-5 60 4.6×250 PY06S05-2546PS

propyl acetamide S-5 60 4.6×250 PP06S05-2546PS

Packing material

Particle size(µm)

Pore size(Å)

Column sizeinnerdiameter×length(mm) Product number

silica S-5 120 4.6×250 SL12S05-2546PS

Polyamine II S-5 120 4.6×250 PB12S05-2546PS

amino S-5 120 4.6×250 NH12S05-2546PS

cyano S-5 120 4.6×250 CN12S05-2546PS

PVA-Sil S-5 120 4.6×250 PV12S05-2546PS

1

2

345

6

7

8

9

10

PDA-230 nmMIX500

450400350300250200150100500

0 1 2 3 4 5 6 7Minutes

8 9 10 11 12 13 14

mV

1. Citral2. Lidocaine3. Ibuprofen4. Caffeine5. Amitriptyline6. Propranolol7. Sulfinpyrazone8. Procainamide9. Cytosine

10. Sulpiride

A p p l i c a t i o n

Column :YMC-PackPVA-Sil(5µm,120Å)250×4.6mmI.D.Flowrate :3.5mL/minOutletpressure:15MPaColumntemp.:40℃Detection :230nmInjectionvolume:5µLMobilephase:CO2withmodifierModifier :Methanolw/0.1%DiethylamineGradientelution:linearchangefrominitial5%modifier-65%

modifierover12.5minutes

1

2

3

0

200

400

600

800

0 1 2 3Minutes

4 5 6 7

mA

U

Q u a l i t y c o n t r o l c h e c k b y S F C

Column :YMC-PackDiol(5µm,120Å)250×4.6mmI.D.Mobilephase:80/20CO2/MethanolFlowrate :2.0mL/minOutletpressure:10MPaColumntemp.:40℃Detection :230nmInjectionvolume:5µL

QCmixcomponents1.Acetophenone2.Caffeine3.Thymine

Ordering information

第03章.indd 92 11.1.28 10:49:37 AM