Series 1002A Electric Level Switch A Reliable Float-Operated Device Operates control equipment and per forms a variety of electrical functions. Contents 1 Operation 2 Installation 3 Specifications 3 Model Code The Series 1002A offers a reliable, float-operated, high or low liquid level sensing device. The Series 1002A is listed by the Canadian Standards Association as certified for hazardous locations, Class I, Group C & D. It can be used to sound alarms, operate control equipment, activate panel lights, or perform any other electrical function. The Series 1002A will operate in liquids with a specific gravity of 0.6 or higher and pressures up to 3000 psi. The field replaceable switch capsule is rated for operation within -40 to 220° F. Operation The Series 1002A utilizes a magnetic proximity reed switch to open or close an electrical circuit. The reed switch is actuated by a permanent magnet. A stainless steel arm, containing the magnet, acts as a counterbalance for the float. As the liquid level varies, the float will position the magnet closer to or farther from the reed switch capsule. The operation of the reed switch available in the The Series 1002A is explained below. The Single Pole Single Throw Reed Switch is normally open. When the magnet is positioned in close proximity with the switch capsule, the contacts close. Engineered Performance Features 3000 psi working pressure Field replaceable switch capsule Approved for Hazardous Locations Class I, Group C&D 316 SST Hex Body SWITCH CAPSULE MAGNET 24" LEADS 2" HEX 9 / 16 " 1 / 2 -14 NPT 1 1 /2 -11 1 /2 NPT 7 1 /16 " 3 1 /4 "

NOR 6300 Broch - Norriseal-WellMark · O#˚˙ % %˚! The Series 1002A may be mounted for either high or low ala rm, normally closed or normally open by simply positioning the body

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: NOR 6300 Broch - Norriseal-WellMark · O#˚˙ % %˚! The Series 1002A may be mounted for either high or low ala rm, normally closed or normally open by simply positioning the body

Series 1002A Electric Level Switch

A Reliable Float-Operated DeviceOperates control equipment and performs a variety of electrical functions.

Contents

1 Operation2 Installation3 Specifications3 Model Code

The Series 1002A offers a reliable, float-operated,high or low liquid level sensing device. The Series 1002A is listed by the CanadianStandards Association as certified for hazardouslocations, Class I, Group C & D. It can be used to sound alarms, operate control equipment, activate panel lights, or perform any other electrical function.

The Series 1002A will operate in liquids with aspecific gravity of 0.6 or higher and pressures upto 3000 psi. The field replaceable switch capsuleis rated for operation within -40 to 220° F.

Operation

The Series 1002A utilizes a magneticproximity reed switch to open or close an electrical circuit. The reed switch isactuated by a permanent magnet. A stainless steel arm, containing the magnet, acts as a counterbalance for thefloat. As the liquid level varies, the float will position the magnet closer to or farther from the reed switch capsule. The operation of the reed switch available in the The Series 1002A is explained below.

The Single Pole Single Throw Reed Switch is normallyopen. When the magnet is positioned in close proximitywith the switch capsule, the contacts close.

EngineeredPerformance

Features

� 3000 psi working pressure

� Field replaceable switch capsule

Approved for Hazardous LocationsClass I, Group C&D 316 SST Hex Body

SWITCH CAPSULEMAGNET

24"LEADS

2" HEX

9⁄16 "

1⁄2 -14NPT11⁄2 -111⁄2NPT

71⁄16 "

31⁄4 "

Page 2: NOR 6300 Broch - Norriseal-WellMark · O#˚˙ % %˚! The Series 1002A may be mounted for either high or low ala rm, normally closed or normally open by simply positioning the body

Orientation

The Series 1002A may be mounted for either highor low alarm, normally closed or normally open by simply positioning the body. The hex body provides flat surface for easy wrenching duringinstallation or positioning.

Typical Installations

2

LOW N. C.

HIGHN. O.

HIGHN. O.

LOW N. C.

Position Normally Closed(Low Level Alarm)

Position Normally Opened(High Level Alarm)

Installation

1½" HALF PIPE COUPLINGVESSEL

FLOAT

SERIES 1002-ASERIES 1002-A

FLOAT

1006 CHAMBER

Page 3: NOR 6300 Broch - Norriseal-WellMark · O#˚˙ % %˚! The Series 1002A may be mounted for either high or low ala rm, normally closed or normally open by simply positioning the body

3

SERIES 1002A SpECIFICATIOnS

Body 316 Stainless Steel

FloatMaterial Maximum Pressure Maximum Temperature

Polypropylene316 Stainless Steel

3000 psi 1500 psi

140° F 220° F

Electrical Maximum Volts Maximum Amp Maximum Switch Load (Resistive)

Single PoleSingle Throw

24 VDC120 VAC

2.0.25

30 Watts30 V.A.

Switch Operating Temperature Range: -40 to 220° F

1002A 316-14-SPST

Code Type

SPSTSingle Pole

Single Throw

SwITCH TypE

Specifications

model Code

How to Order

1. Specify Series 1002A2. Select Model Number

bODy mATERIAL

Type Code

316 SST 316

FLOAT mATERIAL

Type Code

Polypropylene 14

316 SST 40

Page 4: NOR 6300 Broch - Norriseal-WellMark · O#˚˙ % %˚! The Series 1002A may be mounted for either high or low ala rm, normally closed or normally open by simply positioning the body

� In-house engineering and technical support

� In-depth applications experience

� Award-winning innovation and ongoing

product development

� ISO 9001:2008 certified manufacturing

� Over five decades of industry service

� Compliance with all industry standards

and specifications

� Responsive service and prompt delivery

� Field support available worldwide

Please contact your Norriseal representative for more details and assistance in specifying the optimal solution for your application.

Why you can depend on genuine Norriseal products

©2015 Dover Corporation/Norriseal and its affiliates. This manual, including all text andimages, is a copyrighted work of Dover Corporation/Norriseal and its affiliates. It may notbe, in whole or in part, photocopied, scanned, or otherwise reproduced, revised, or pub-licly displayed, without prior written permission from Norriseal. This manual is for useonly with the new Norriseal valves and/or controllers listed in the manual. It may not bedistributed with, and is not for use with, any remanufactured products.

Due to the continuous improvement program at Norriseal, specifications and/or pricesare subject to change without notice or obligation.