DESCRIPTION: ICS 309 Curing Compound is a non-yellowing, solvent-based acrylic concrete curing compound formulated for application on freshly placed concrete. When properly applied, it forms a film that optimizes water retention in freshly placed concrete. COVERAGE: 200 ft.²/gal. Depending on surface finish, coverage may vary due to porosity and condition of the concrete. SPECIFICATIONS: • ASTM C309, Class B, Type 1 • AASHTO M 148, Class B, Type 1 APPLICATION: Surface Preparation ... Apply as soon as all surface water has disappeared and the concrete surface will not be marred by walking workers. Application Method … Use a sprayer or short-nap roller to apply a uniform film. Avoid puddling in low areas. If puddles occur, brush or roll them out. A standard industrial-grade sprayer, such as a Chapin 19069, equipped with Viton fittings and a spray nozzle that produces a flow of 0.5 GPM under 40 psi of pressure, is recommended. Apply over the entire surface; avoid puddling in low areas. Mixing ... For optimum performance, gentle mixing or agitation is recommended. CAUTION: TO AVOID FOAMING, DO NOT MIX EXCESSIVELY. Drying Time ... Product dries quickly. Drying times will vary depending on application rate, temperature, humidity, and project conditions. Restrict foot traffic for at least four hours. Twelve hours is preferable. Cleanup ... Clean tools after use with a solvent such as xylene or toluene. PRECAUTIONS: FOR OUTSIDE/EXTERIOR APPLICATION ONLY. ICS 309 CURING COMPOUND IS FLAMMABLE. KEEP AWAY FROM ALL OPEN FLAMES, SPARKS, IGNITION SOURCES, etc. Use with adequate ventilation and block all HVAC ventilation ducts which may spread product vapors - vapors are flammable and heavier than air. ICS 309 Curing Compound must be applied without diluting or thinning. Surfaces cured with ICS 309 Curing Compound may become slippery under certain conditions. ICS 309 Curing Compound should not be applied in direct sunlight or in high temperature conditions. These conditions cause rapid evaporation, preventing proper film formation. Surface temperature of the concrete must be between 40° – 90° F at time of application to allow for proper film formation. When Quality Counts 425 West 1700 South | Salt Lake City , Utah | 8 0 1. 4 8 6 . 5 3 11 2660 Pennsylvania Ave | Ogden, Utah | 8 0 1. 6 2 1. 3 7 5 0 1280 East 700 North | St. George , Utah | 435.628.8310 2005 North 600 West, Suite H | Logan , Utah | 435.787.8755 3710 Bombardier St. | Idaho Falls, Idaho | 208.522.4949 487 South 1325 West | Orem, Utah | 8 0 1. 2 2 1. 2 6 4 3 ICS 309 ICS 309 Non-Yellowing, Acrylic Curing Compound www.ics50.com 10/31/17

Non-Yellowing, Acrylic Curing Compound · 31.10.2017  · • AASHTO M 148, Class B, Type 1 APPLICATION: Surface Preparation ... Apply as soon as all surface water has disappeared

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Non-Yellowing, Acrylic Curing Compound · 31.10.2017  · • AASHTO M 148, Class B, Type 1 APPLICATION: Surface Preparation ... Apply as soon as all surface water has disappeared

DESCRIPTION:ICS 309 Curing Compound is a non-yellowing, solvent-based acrylic concrete curing compound formulated for application on freshly placed concrete. When properly applied, it forms a �lm that optimizes water retention in freshly placed concrete.

COVERAGE:200 ft.²/gal. Depending on surface �nish, coverage may vary due to porosity and condition of the concrete.

SPECIFICATIONS:• ASTM C309, Class B, Type 1• AASHTO M 148, Class B, Type 1

APPLICATION:Surface Preparation ... Apply as soon as all surface water has disappeared and the concrete surface will not be marred by walking workers.

Application Method … Use a sprayer or short-nap roller to apply a uniform �lm. Avoid puddling in low areas. If puddles occur, brush or roll them out. A standard industrial-grade sprayer, such as a Chapin 19069, equipped with Viton �ttings and a spray nozzle that produces a �ow of 0.5 GPM under 40 psi of pressure, is recommended. Apply over the entire surface; avoid puddling in low areas.

Mixing ... For optimum performance, gentle mixing or agitationis recommended. CAUTION: TO AVOID FOAMING, DO NOT MIXEXCESSIVELY.

Drying Time ... Product dries quickly. Drying times will varydepending on application rate, temperature, humidity, and project conditions. Restrict foot tra�c for at least four hours. Twelve hoursis preferable.

Cleanup ... Clean tools after use with a solvent such as xylene or toluene.

PRECAUTIONS:FOR OUTSIDE/EXTERIOR APPLICATION ONLY. ICS 309 CURING COMPOUND IS FLAMMABLE. KEEP AWAY FROM ALL OPEN FLAMES, SPARKS, IGNITION SOURCES, etc. Use with adequate ventilation and block all HVAC ventilation ducts which may spread product vapors - vapors are �ammable and heavier than air. ICS 309 Curing Compound must be applied without diluting or thinning. Surfaces cured with ICS 309 Curing Compound may become slippery under certain conditions.

ICS 309 Curing Compound should not be applied in directsunlight or in high temperature conditions. These conditions cause rapid evaporation, preventing proper �lm formation.Surface temperature of the concrete must be between 40° –90° F at time of application to allow for proper �lm formation.

When Quality Counts4 2 5 We s t 170 0 S o u t h | Sa lt L ake C i t y , U t a h | 8 0 1. 4 8 6. 53 11

2 6 6 0 Pe n n s y l v a n i a Av e | O g d en, U t a h | 8 0 1. 62 1. 375 01 2 8 0 E a s t 70 0 N o r t h | St . G e org e, U t a h | 43 5. 62 8. 83 10

2 0 0 5 N o r t h 6 0 0 We s t , S u i t e H | Log an, U t a h | 43 5. 787. 87 5 537 10 B o m b a r d i e r S t . | I d ah o Fal ls, I d a h o | 2 0 8. 522. 4 94 9

4 87 S o u t h 1 3 2 5 We s t | O re m, U t a h | 8 0 1. 22 1. 2 643

ICS 309ICS 309Non-Yellowing, Acrylic Curing Compound

w w w . i c s 5 0 . c o m10/31/17