Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
Three Spires Acoustics 2 Syke Ings
Iver
Bucks
SL09ET.
Tel: 01753 651185 Mob: 07939324063
[email protected] www.threespiresacoustics.co.uk
Company Representative
Chris Hurst
Noise Management Compliance Report
SW4 2017 & House of Common Concert Clapham Common, London SW4 Saturday 26th to Monday 28th August 2017
for Lock n Load Events Ltd .
Prepared for: Report Ref: CH/NMCR2017/27
Andrew Mattle Lock n Load Events Ltd Unit 11.G.01, The Leathermarket 11-13 Weston Street London SE1 3ER
Three Spires Acoustics CH/NMCR/2017/27 SW4 & House of Common 2017- Noise Management Compliance Report
1
DOCUMENT CONTROL
Revision Date: Prepared by: Client Doc Ref Reason for Issue:
1.0 04/09/2017 Chris Hurst LocknLoad Events Ltd CH/NMCR/2017/27 Initial
DISCLAIMER This report was completed by Three Spires Acoustics Ltd on the basis of a defined programme of work and terms and conditions agreed
with the Client. The report has been prepared with all reasonable skill, care and diligence within the terms of the Contract with the Client
and taking into account the project objectives, the agreed scope of works, prevailing site conditions and the degree of manpower and
resources allocated to the project.
Three Spires Acoustics Ltd accepts no responsibility whatsoever, following the issue of the report, for any matters arising outside the
agreed scope of the works. This report is issued in confidence to the Client and by Three Spires Acoustics Ltd has no responsibility of
whatsoever nature to third parties to whom this report or any part thereof is made known. Any such party relies upon the report at their
own risk. Unless specifically assigned or transferred within the terms of the agreement, by Three Spires Acoustics Ltd retains all copyright
and other intellectual property rights, on and over the report and its contents.
© Three Spires Acoustics Ltd
Three Spires Acoustics CH/NMCR/2017/27 SW4 & House of Common 2017- Noise Management Compliance Report
2
Table of Contents
1. Introduction .......................................................................................... 4
2. Premises Licence Noise Control Conditions ........................................... 4
2.1 Conditions attached after a hearing by the licensing authority .................................... 4
2.2 Conditions attached after Temporary Planning Consent by LPA ................................... 5
3. Sound Propagation and Pre-Event Tests ................................................ 5
3.1 Sound Monitoring Control............................................................................................... 5
4. Results .................................................................................................. 5
4.1 Saturday 26th August 2017 – Hospice, Windmill Drive & C.C. West Monitoring Results
6
4.1.1 LAeq,15minutes Time Profile Results ....................................................................................................... 6
4.1.2 LCeq,15minutes Time Profile Results ....................................................................................................... 6
4.1.3 94 C.C. North LAeq & LCeq,15minutes Time Profile Results .................................................................... 7
4.2 Sunday 27th August 2017 - Hospice, Windmill Drive & C.C. West Monitoring Results.. 7
4.2.1 LAeq 15minutes Time Profile Results ....................................................................................................... 7
4.2.2 LCeq 5minutes Time Profile Results ......................................................................................................... 8
4.2.3 94 C.C. North LAeq & LCeq 15minutes Time Profile Results .................................................................... 8
4.3 Monday 28th August 2017 - Hospice, Windmill Drive & C.C. West Monitoring Results 9
4.3.1 LAeq,15minutes Time Profile Results ....................................................................................................... 9
4.3.2 LCeq,15minutes Time Profile Results ....................................................................................................... 9
4.3.3 94 C.C. North LAeq & LCeq 15minutes Time Profile Results .................................................................. 10
4.4 Offsite Monitoring Results ........................................................................................... 11
4.5 Results Discussion ........................................................................................................ 11
5. Complaints .......................................................................................... 12
5.1 Discussion ..................................................................................................................... 12
6. Conclusion .......................................................................................... 12
: Results ............................................................................... 13
: Complaints Google Map ..................................................... 16
: Weather Data ..................................................................... 17
Glossary of Terms ................................................................. 18
Three Spires Acoustics CH/NMCR/2017/27 SW4 & House of Common 2017- Noise Management Compliance Report
3
List of Tables
Table 1: – Summary of Premises Licence & Planning Consent Noise Control Conditions. ..................... 4
Table 2 Saturday 10th June 2017- Offsite Noise Monitoring Results .................................................... 11
Table 3: SW4 Saturday 26th August 2017- External Monitoring Results Table ..................................... 13
Table 4 SW4 Sunday 27th August 2017- External Monitoring Results Table......................................... 14
Table 5 House of Common Monday 28th August 2017- External Monitoring Results Table ................ 15
List of Figures
Figure 1: SW4 Saturday 26th August 2017- Offsite Monitoring Locations LAeq,15minute Time Profile 6
Figure 2: Saturday 26th August 2017- Offsite Monitoring Locations LCeq,15minute Time Profile ....... 6
Figure 3: Saturday 26th August 2017- 94 CC. North LAeq & LCeq,15minute Time Profile ...................... 7
Figure 4: Sunday 27th August 2017- Offsite Monitoring Locations LAeq,15minute Time Profile ........... 7
Figure 5: Sunday 27th August 2017- Offsite Monitoring Locations LCeq,15minute Time Profile ......... 8
Figure 6 Sunday 27th 2017- 94 CC. North LAeq & LCeq,15minute Time Profile ..................................... 8
Figure 7: Monday 28th August 2017- Offsite Monitoring Locations LAeq,15minute Time Profile ......... 9
Figure 8: Monday 28th August 2017- Offsite Monitoring Locations LCeq,15minute Time Profile ........ 9
Figure 9: Monday 28th August 2017- 94 C.C. North LAeq & LCeq,15minute Time Profile .................. 10
Figure 10 Complaints Google Map ........................................................................................................ 16
Figure 11 Wind Speed & Direction 26th to 28th August 2017- source www.wunderground.com ........ 17
Three Spires Acoustics CH/NMCR/2017/27 SW4 & House of Common 2017- Noise Management Compliance Report
4
1. Introduction
Three Spires Acoustics Ltd have been commissioned by LocknLoad Evets Ltd to assist in the control
of sound at SW4 2017 Music and Dance Festival on Saturday 26th & Sunday 27th August 2017 and
the House of Common Concert on Bank Holiday Monday 28th August 2017 , which took place on
Clapham Common, London, SW4. The purpose of this report is to provide a summary of the music
noise measurements undertaken at various locations specified within the Premises Licence issued by
the Licensing Authority at London Borough Lambeth (LBL) and to demonstrate compliance with the
noise condition limits set within the licence. The report supplements the Noise Management Plan
(NMP) ref CH/NMP/2016/30Rev2 issued before the event which detailed the noise control
methodology which was implemented throughout the concerts.
2. Premises Licence Noise Control Conditions
The premises licence conditions relevant to noise are reproduced in Table 1 below. The limit levels
reflect LB Lambeth’s Policy Guidance on the control of sound at out-door events (2016). and the
conditions attached after a Premises Licence Hearing by the Licensing Authority and planning consent
and are reproduced in Section 2.1 below.
Table 1: – Summary of Premises Licence & Planning Consent Noise Control Conditions.
Location Condition Level
dB(A)1 dB(C)2
MP1- Rear of 8A Windmill Drive 75 90
MP2 - 14 Clapham Common West (Wandsworth) 70 85
MP3 - Trinity Hospice 30 Clapham Common North 75 90
MP4 – 94 Clapham Common Northside (Wandsworth) 70 88
MP5- 53 Clapham Common South Side 75 90
MP6 - Notre Dame Estate, to be located at the point outside the residential property closest to the event site boundary
75 90
1. The LAeq, 15minute Music Noise Level (MNL) measured for any 15 minute period of the event outside any noise sensitive premises. (freefield)
2. The LCeq,15minute Bass Music Noise Level (LFMNL) measured for any 15 minute period of the event outside any noise sensitive
premises.(freefield)
2.1 Conditions attached after a hearing by the licensing authority
A Maximum music noise level (MNL) restriction of 70dB(A) Leq 15 Minutes and a low frequency MNL (LFMNL) restriction of 85 dB (C) Leq15 Minutes (free field) outside any noise sensitive premises at the Clapham Common West Side monitoring location in Wandsworth ( i.e. 14 Clapham Common West Side) .
A Maximum music noise level (MNL) restriction of 70dB(A) Leq 15 Minutes and a low frequency MNL (LFMNL) restriction of 88 dB (C) Leq15 Minutes (free field) outside any noise sensitive premises at 94 Clapham Common Northside in Wandsworth ) . The second respondent will monitor this location for the duration of the event and supply readings to all parties thereafter.
All music to cease at 22:00 on Monday 28th August 2017
Three Spires Acoustics CH/NMCR/2017/27 SW4 & House of Common 2017- Noise Management Compliance Report
5
2.2 Conditions attached after Temporary Planning Consent by LPA
Following a decision by LB Lambeth planning committee for a temporary use of the site, a further two noise monitoring locations were added and are detailed below and reproduced in table 1 above;
1. The noise monitoring at Large and Major events shall include an additional noise monitoring station on the Notre Dame Estate, to be located at the point outside the residential property closest to the event site boundary.
2. 53 Clapham Common South Side monitoring point – this is at the same levels as Trinity hospice, and Windmill drive – 75 dB(A) and 90 dB(C).
Reason: In order to monitor the impact of noise on residential properties on the estate (Policy Q2 and
PN5 of the London Borough of Lambeth Local Plan (2015))
3. Sound Propagation and Pre-Event Tests
A full propagation test for all stages was undertaken on Friday 25th August in order to establish a
correlation between the specified off site limits at the designated locations within the Premises
Licence and the Front of House position for each stage. This established objective target limits of
approximately 97dB(A) to 100dB(A) which would assist in the control at external locations.
3.1 Sound Monitoring Control
Sound levels at the five main stages and the four offsite monitoring locations were continually
monitored in terms of 15 minute and 1 minute LAeq and LCeq. This information was then relayed to
a monitored central control point. Rotational monitoring at the other offsite positions were relayed
back to the central control point via two-way radio/smart phone application. When necessary an
adjustment intervention request was made via the central control point to the sound engineers.
During the event levels were generally maintained at the propagation test levels and where
necessary either increased or decreased to allow sufficient entertainment levels whilst remaining
compliant with the licence conditions. As the music played was dynamic in nature with music noise
level in each of the stage areas fluctuating regularly, level changes could be made in order to affect
this objective.
4. Results
A summary of the measurement results is provided in Section 3 below. A full set of measurement
results for offsite and all stages is presented in Appendix A
Three Spires Acoustics CH/NMCR/2017/27 SW4 & House of Common 2017- Noise Management Compliance Report
6
4.1 Saturday 26th August 2017 – Hospice, Windmill Drive & C.C. West Monitoring
Results
4.1.1 LAeq,15minutes Time Profile Results Figure 1: SW4 Saturday 26th August 2017- Offsite Monitoring Locations LAeq,15minute Time Profile
4.1.2 LCeq,15minutes Time Profile Results Figure 2: Saturday 26th August 2017- Offsite Monitoring Locations LCeq,15minute Time Profile
40
45
50
55
60
65
70
75
80
Leve
l dB
(A)
Time
SW4 2017 - Offiste LAeq,15 minute Time Hisotry Profile Measurements
Hospice LAeq CCW LAeq Windmill LAeq Condition LAeq
50
55
60
65
70
75
80
85
90
95
Leve
l dB
C
Time
SW4 2017 - Offiste LAeq,15 minute Time Hisotry Profile Measurements
Hospice LCeq CCW LCeq Windmill LCeq Condition LCeq
Three Spires Acoustics CH/NMCR/2017/27 SW4 & House of Common 2017- Noise Management Compliance Report
7
4.1.3 94 C.C. North LAeq & LCeq,15minutes Time Profile Results Figure 3: Saturday 26th August 2017- 94 CC. North LAeq & LCeq,15minute Time Profile
4.2 Sunday 27th August 2017 - Hospice, Windmill Drive & C.C. West Monitoring
Results
4.2.1 LAeq 15minutes Time Profile Results Figure 4: Sunday 27th August 2017- Offsite Monitoring Locations LAeq,15minute Time Profile
40
50
60
70
80
90
100
dB
Time
SW4 2017 -26th August 2017-94 CCN LAeq & LCeq 15minute Time Hisotry Profile Measurements
94CCN LAeq 94CCN LCeq Condition LAeq Condition LCeq
40
45
50
55
60
65
70
75
80
Leve
l dB
(A)
Time
SW4 2017 - 27th August 2017 Offiste LAeq,15 minute Time Hisotry Profile Measurements
Hospice LAeq CCW LAeq Windmill LAeq Condition LAeq
Three Spires Acoustics CH/NMCR/2017/27 SW4 & House of Common 2017- Noise Management Compliance Report
8
4.2.2 LCeq 5minutes Time Profile Results Figure 5: Sunday 27th August 2017- Offsite Monitoring Locations LCeq,15minute Time Profile
4.2.3 94 C.C. North LAeq & LCeq 15minutes Time Profile Results Figure 6 Sunday 27th 2017- 94 CC. North LAeq & LCeq,15minute Time Profile
50
55
60
65
70
75
80
85
90
95
Leve
l dB
C
Time
SW4 2017 - 27th August 2017 Offiste LCeq,15 minute Time Hisotry Profile Measurements
Hospice LCeq CCW LCeq Windmill LCeq Condition LCeq
40
50
60
70
80
90
100
Leve
l dB
Time
SW4 2017 27th August -94 CCN LAeq & LCeq 15minute Time Hisotry Profile Measurements
94CCN LAeq 94CCN LCeq Condition LAeq Condition LCeq
Three Spires Acoustics CH/NMCR/2017/27 SW4 & House of Common 2017- Noise Management Compliance Report
9
4.3 Monday 28th August 2017 - Hospice, Windmill Drive & C.C. West Monitoring
Results
4.3.1 LAeq,15minutes Time Profile Results Figure 7: Monday 28th August 2017- Offsite Monitoring Locations LAeq,15minute Time Profile
4.3.2 LCeq,15minutes Time Profile Results Figure 8: Monday 28th August 2017- Offsite Monitoring Locations LCeq,15minute Time Profile
40
45
50
55
60
65
70
75
80
Leve
l dB
(A)
Time
House of Common 2017 - Offiste LAeq,15 minute Time Hisotry Profile Measurements
Hospice LAeq CCW LAeq Windmill LAeq Condition LAeq
50
55
60
65
70
75
80
85
90
95
Leve
l dB
C
Time
House of Common 2017 - Offiste LAeq,15 minute Time Hisotry Profile Measurements
Hospice LCeq CCW LCeq Windmill LCeq Condition LCeq
Three Spires Acoustics CH/NMCR/2017/27 SW4 & House of Common 2017- Noise Management Compliance Report
10
4.3.3 94 C.C. North LAeq & LCeq 15minutes Time Profile Results Figure 9: Monday 28th August 2017- 94 C.C. North LAeq & LCeq,15minute Time Profile
40
50
60
70
80
90
100
Leve
l dB
Time
House of Common 2017 28th August -94 CCN LAeq & LCeq 15minute Time Hisotry Profile Measurements
94CCN LAeq 94CCN LCeq Condition LAeq Condition LCeq
Three Spires Acoustics CH/NMCR/2017/27 SW4 & House of Common 2017- Noise Management Compliance Report
11
4.4 Offsite Monitoring Results
Sound levels at the other offsite monitoring locations (MP5 & MP6 ) were monitored on a
rotational basis, other locations were monitored where possible in relation to a noise complaint. A
summary of the results for each day of the concerts is presented in Tables 2 below;
Table 2 Saturday 10th June 2017- Offsite Noise Monitoring Results
4.5 Results Discussion
Offsite levels at the four permanent monitoring locations (MP1 to MP4) and the two other
locations (MP5 & MP6) remained compliant with the Premises Licence requirements throughout the
concerts, with the exception of the a limited number of marginal exceedances of less than 2dB at the
Hospice and Windmill monitoring locations on Saturday 26th and Sunday 27th August.
Front of House levels at all stages were maintained at similar levels to the propagation test.
Both LB Lambeth and LB Wandsowrth employed independent consultants to monitor noise levels
and we understand that they did not monitor any exceedances at any of the prescribed locations
within the Premises Licence. No reduction request from officers were made and at no time did the
officers indicate that music noise was unreasonable or causing a public nuisance. The general
feedback on noise management was positive.
Location Start Time Duration LAeq LCeq Comment
MP6- Notre Dame Estate 26/08/2017 12:59 00:15:05 61 82 Music audible. Traffic noise dominant
MP5- 53 Clapham Common South Side 26/08/2017 13:18 00:15:03 67 85 Music clearly audible. Traffic noise contribution
MP6- Notre Dame Estate 26/08/2017 14:15 00:15:30 62 82 Music audible. Traffic noise dominant
MP5- 53 Clapham Common South Side 26/08/2017 14:35 00:15:03 73 84 Music audible. Heavy Traffic
MP6- Notre Dame Estate 26/08/2017 15:14 00:15:05 64 84 Music clearly audible. Traffic noise contribution
MP5- 53 Clapham Common South Side 26/08/2017 15:33 00:15:50 68 84 Music clearly audible. Traffic noise contribution
MP5- 53 Clapham Common South Side 26/08/2017 16:40 00:16:01 67 82 Music audible. Heavy Traffic
MP6- Notre Dame Estate 26/08/2017 17:51 00:19:46 71 86 Music audible. Traffic noise dominant
MP6- Notre Dame Estate 26/08/2017 18:14 00:16:08 66 85 Music audible. Traffic noise dominant
MP6- Notre Dame Estate 27/08/2017 11:59 00:15:05 61 82 Music audible. Traffic noise dominant
MP5- 53 Clapham Common South Side 27/08/2017 12:19 00:17:12 66 84 Music clearly audible. Traffic noise contribution
MP6- Notre Dame Estate 27/08/2017 13:51 00:16:21 62 81 Music audible. Traffic noise dominant
MP5- 53 Clapham Common South Side 27/08/2017 14:12 00:19:06 67 86 Music clearly audible. Traffic noise contribution
38 CC. North 27/08/2017 14:46 00:15:14 66 86 Music audible. Traffic noise dominant
MP6- Notre Dame Estate 27/08/2017 15:36 00:15:37 65 82 Music audible. Traffic noise dominant
MP5- 53 Clapham Common South Side 27/08/2017 15:58 00:16:15 66 84 Music clearly audible. Traffic noise contribution
MP6- Notre Dame Estate 27/08/2017 16:44 00:16:00 62 83 Music audible. Traffic noise dominant
MP5- 53 Clapham Common South Side 27/08/2017 19:27 00:15:12 67 86 Music clearly audible. Traffic noise contribution
MP6- Notre Dame Estate 27/08/2017 19:46 00:15:22 65 84 Music audible. Traffic noise dominant
MP5- 53 Clapham Common South Side 27/08/2017 20:12 00:15:06 66 85 Music clearly audible. Traffic noise contribution
MP6- Notre Dame Estate 27/08/2017 21:06 00:15:02 65 86 Music audible. Traffic noise dominant
MP5- 53 Clapham Common South Side 28/08/2017 13:18 00:18:16 68 82 Music clearly audible. Traffic noise contribution
MP6- Notre Dame Estate 28/08/2017 13:41 00:15:02 65 80 Music audible. Traffic noise dominant
MP6- Notre Dame Estate 28/08/2017 16:30 00:15:17 65 82 Music audible. Traffic noise dominant
MP5- 53 Clapham Common South Side 28/08/2017 16:49 00:15:20 65 81 Music clearly audible. Traffic noise contribution
MP6- Notre Dame Estate 28/08/2017 17:09 00:15:02 66 81 Music audible. Traffic noise dominant
MP5- 53 Clapham Common South Side 28/08/2017 17:28 00:16:54 69 82 Music audible. Traffic noise dominant
59 CC. South 28/08/2017 19:08 00:16:12 67 82 Music clearly audible. Traffic noise contribution
MP5- 53 Clapham Common South Side 28/08/2017 20:28 00:15:23 68 82 Music clearly audible. Traffic noise contribution
MP6- Notre Dame Estate 28/08/2017 20:49 00:15:03 64 78 Music audible. Traffic noise dominant
Three Spires Acoustics CH/NMCR/2017/27 SW4 & House of Common 2017- Noise Management Compliance Report
12
5. Complaints
A total of 26 music noise complaints were received by the Event Management Team; 12 during
Saturday, 8 during Sunday and 6 during Monday. Some of these were made on more than one
occasion by the same resident. Where possible complainants were contacted by a member of Three
Spires staff. A live Goggle map of complaints was also updated during the concerts and this is
presented in Figure 4 in Appendix C.
The geographical spread on complaints for each day correlates with the wind direction i.e. Saturday
and Sunday the wind was predominantly from the south west and west, increasing the perceived
levels at the community around Clapham Common West side. On Sunday evening and during
Monday the wind directed changed to a predominantly easterly/south easterly direction and
increased perceived noise levels to the north of the common.
There was a decrease in the numbers of complaints from 2016 from a total of 36.
5.1 Discussion
1) Both LB Lambeth and LB Wandsowrth employed independent consultants to monitor noise
levels and we understand that they did not monitor any exceedances at any of the
prescribed locations within the Premises Licence. No reduction request from
officers/consultants were made and at no time did the officers indicate that music noise was
unreasonable or causing a public nuisance. The general feedback on noise management was
positive.
2) It is considered that the Notre Dame Estate monitoring position is unnecessary and is to a
large degree duplicated by the Clapham Common South location i.e. compliance at CCS
equates to compliance at the Notre Dame position. It is advised that this position is removed
by the local authority as it takes consultant resources away from other noise management
functions during the event.
6. Conclusion
Three Spires Acoustics have recommended procedures for event sound control for SW4 and House
of Common concerts 2017 which were satisfactorily implemented for the duration of the event. It is
considered that this report demonstrates compliance with the relevant noise control conditions
detailed within the events Premises Licence and the objectives of the Licensing Act 2003.
Three Spires Acoustics CH/NMCR/2017/27 SW4 & House of Common 2017- Noise Management Compliance Report
13
: Results
Table 3: SW4 Saturday 26th August 2017- External Monitoring Results Table
Hospice Report CC WEST Report Windmill Report 94CC NORTH Report
Start Stop LAeq LCeq Start Stop LAeq LCeq Start Stop LAeq LCeq Start Stop LAeq LCeq
26/08/2017 10:00 26/08/2017 10:15 61 73
26/08/2017 10:15 26/08/2017 10:30 62 73
26/08/2017 10:30 26/08/2017 10:45 61 74 26/08/2017 10:40 26/08/2017 10:45 67 70
26/08/2017 10:45 26/08/2017 11:00 62 73 26/08/2017 10:45 26/08/2017 11:00 53 66
26/08/2017 11:00 26/08/2017 11:15 62 73 26/08/2017 11:00 26/08/2017 11:15 53 65
26/08/2017 11:15 26/08/2017 11:30 61 83 26/08/2017 11:15 26/08/2017 11:30 53 67 26/08/2017 11:15 26/08/2017 11:30 59 72
26/08/2017 11:30 26/08/2017 11:45 64 84 26/08/2017 11:30 26/08/2017 11:45 54 75 26/08/2017 11:30 26/08/2017 11:45 60 77
26/08/2017 11:45 26/08/2017 12:00 64 84 26/08/2017 11:45 26/08/2017 12:00 55 76 26/08/2017 11:45 26/08/2017 12:00 60 77
26/08/2017 12:00 26/08/2017 12:15 68 84 26/08/2017 12:00 26/08/2017 12:15 55 76 26/08/2017 12:00 26/08/2017 12:15 60 76
26/08/2017 12:15 26/08/2017 12:30 68 84 26/08/2017 12:15 26/08/2017 12:30 59 75 26/08/2017 12:15 26/08/2017 12:30 62 78
26/08/2017 12:30 26/08/2017 12:45 69 87 26/08/2017 12:30 26/08/2017 12:45 54 75 26/08/2017 12:30 26/08/2017 12:45 66 77
26/08/2017 12:45 26/08/2017 13:00 69 86 26/08/2017 12:45 26/08/2017 13:00 54 78 26/08/2017 12:45 26/08/2017 13:00 62 76
26/08/2017 13:00 26/08/2017 13:15 67 86 26/08/2017 13:00 26/08/2017 13:15 54 76 26/08/2017 13:00 26/08/2017 13:15 66 78
26/08/2017 13:15 26/08/2017 13:30 67 87 26/08/2017 13:15 26/08/2017 13:30 53 76 26/08/2017 13:15 26/08/2017 13:30 63 77
26/08/2017 13:30 26/08/2017 13:45 67 86 26/08/2017 13:30 26/08/2017 13:45 55 80 26/08/2017 13:30 26/08/2017 13:45 62 78
26/08/2017 13:45 26/08/2017 14:00 68 87 26/08/2017 13:45 26/08/2017 14:00 53 77 26/08/2017 13:45 26/08/2017 14:00 62 77
26/08/2017 14:00 26/08/2017 14:15 68 86 26/08/2017 14:00 26/08/2017 14:15 55 79 26/08/2017 14:00 26/08/2017 14:15 63 80
26/08/2017 14:15 26/08/2017 14:30 67 86 26/08/2017 14:15 26/08/2017 14:30 53 77 26/08/2017 14:22 26/08/2017 14:30 67 78
26/08/2017 14:30 26/08/2017 14:45 68 87 26/08/2017 14:30 26/08/2017 14:45 55 79 26/08/2017 14:30 26/08/2017 14:45 68 78
26/08/2017 14:45 26/08/2017 15:00 68 87 26/08/2017 14:45 26/08/2017 15:00 56 78 26/08/2017 14:45 26/08/2017 15:00 66 86 26/08/2017 14:45 26/08/2017 15:00 64 76
26/08/2017 15:00 26/08/2017 15:15 69 86 26/08/2017 15:00 26/08/2017 15:15 60 80 26/08/2017 15:00 26/08/2017 15:15 66 88 26/08/2017 15:00 26/08/2017 15:15 66 79
26/08/2017 15:15 26/08/2017 15:30 67 85 26/08/2017 15:15 26/08/2017 15:30 60 80 26/08/2017 15:15 26/08/2017 15:30 66 88 26/08/2017 15:15 26/08/2017 15:30 62 78
26/08/2017 15:30 26/08/2017 15:45 67 84 26/08/2017 15:30 26/08/2017 15:45 57 76 26/08/2017 15:30 26/08/2017 15:45 66 87 26/08/2017 15:30 26/08/2017 15:45 66 76
26/08/2017 15:45 26/08/2017 16:00 66 87 26/08/2017 15:45 26/08/2017 16:00 58 78 26/08/2017 15:45 26/08/2017 16:00 66 86 26/08/2017 15:45 26/08/2017 16:00 64 78
26/08/2017 16:00 26/08/2017 16:15 70 86 26/08/2017 16:00 26/08/2017 16:15 57 81 26/08/2017 16:00 26/08/2017 16:15 67 88 26/08/2017 16:00 26/08/2017 16:15 62 79
26/08/2017 16:15 26/08/2017 16:30 70 87 26/08/2017 16:15 26/08/2017 16:30 56 79 26/08/2017 16:15 26/08/2017 16:30 67 87 26/08/2017 16:15 26/08/2017 16:30 63 78
26/08/2017 16:30 26/08/2017 16:45 71 86 26/08/2017 16:30 26/08/2017 16:45 59 83 26/08/2017 16:30 26/08/2017 16:45 68 89 26/08/2017 16:30 26/08/2017 16:45 64 81
26/08/2017 16:45 26/08/2017 17:00 68 86 26/08/2017 16:45 26/08/2017 17:00 58 79 26/08/2017 16:45 26/08/2017 17:00 66 87 26/08/2017 16:45 26/08/2017 17:00 65 79
26/08/2017 17:00 26/08/2017 17:15 67 86 26/08/2017 17:00 26/08/2017 17:15 58 83 26/08/2017 17:00 26/08/2017 17:15 67 89 26/08/2017 17:00 26/08/2017 17:15 61 80
26/08/2017 17:15 26/08/2017 17:30 67 86 26/08/2017 17:15 26/08/2017 17:30 60 84 26/08/2017 17:15 26/08/2017 17:30 67 89 26/08/2017 17:15 26/08/2017 17:30 61 80
26/08/2017 17:30 26/08/2017 17:45 68 85 26/08/2017 17:30 26/08/2017 17:45 59 82 26/08/2017 17:30 26/08/2017 17:45 68 89 26/08/2017 17:30 26/08/2017 17:45 62 80
26/08/2017 17:45 26/08/2017 18:00 67 88 26/08/2017 17:45 26/08/2017 18:00 58 79 26/08/2017 17:45 26/08/2017 18:00 66 87 26/08/2017 17:45 26/08/2017 18:00 64 78
26/08/2017 18:00 26/08/2017 18:15 69 89 26/08/2017 18:00 26/08/2017 18:15 60 84 26/08/2017 18:00 26/08/2017 18:15 69 89 26/08/2017 18:00 26/08/2017 18:15 61 80
26/08/2017 18:15 26/08/2017 18:30 70 87 26/08/2017 18:15 26/08/2017 18:30 58 81 26/08/2017 18:15 26/08/2017 18:30 69 88 26/08/2017 18:15 26/08/2017 18:30 65 78
26/08/2017 18:30 26/08/2017 18:45 70 90 26/08/2017 18:30 26/08/2017 18:45 59 80 26/08/2017 18:30 26/08/2017 18:45 68 88 26/08/2017 18:30 26/08/2017 18:45 62 78
26/08/2017 18:45 26/08/2017 19:00 71 85 26/08/2017 18:45 26/08/2017 19:00 62 86 26/08/2017 18:45 26/08/2017 19:00 71 92 26/08/2017 18:45 26/08/2017 19:00 65 81
26/08/2017 19:00 26/08/2017 19:15 67 87 26/08/2017 19:00 26/08/2017 19:15 59 78 26/08/2017 19:00 26/08/2017 19:15 68 88 26/08/2017 19:00 26/08/2017 19:15 61 78
26/08/2017 19:15 26/08/2017 19:30 70 88 26/08/2017 19:15 26/08/2017 19:30 61 84 26/08/2017 19:15 26/08/2017 19:30 70 90 26/08/2017 19:15 26/08/2017 19:30 64 80
26/08/2017 19:30 26/08/2017 19:45 71 89 26/08/2017 19:30 26/08/2017 19:45 62 85 26/08/2017 19:30 26/08/2017 19:45 70 92 26/08/2017 19:30 26/08/2017 19:45 62 81
26/08/2017 19:45 26/08/2017 20:00 70 89 26/08/2017 19:45 26/08/2017 20:00 62 85 26/08/2017 19:45 26/08/2017 20:00 70 91 26/08/2017 19:45 26/08/2017 20:00 63 82
26/08/2017 20:00 26/08/2017 20:15 70 89 26/08/2017 20:00 26/08/2017 20:15 62 86 26/08/2017 20:00 26/08/2017 20:15 70 90 26/08/2017 20:00 26/08/2017 20:15 63 82
26/08/2017 20:15 26/08/2017 20:30 69 87 26/08/2017 20:15 26/08/2017 20:30 63 84 26/08/2017 20:15 26/08/2017 20:30 69 90 26/08/2017 20:15 26/08/2017 20:30 64 82
26/08/2017 20:30 26/08/2017 20:45 69 89 26/08/2017 20:30 26/08/2017 20:45 62 85 26/08/2017 20:30 26/08/2017 20:45 68 88 26/08/2017 20:30 26/08/2017 20:45 62 82
26/08/2017 20:45 26/08/2017 21:00 70 89 26/08/2017 20:45 26/08/2017 21:00 62 86 26/08/2017 20:45 26/08/2017 21:00 68 90 26/08/2017 20:45 26/08/2017 21:00 62 82
26/08/2017 21:00 26/08/2017 21:15 70 89 26/08/2017 21:00 26/08/2017 21:15 62 85 26/08/2017 21:00 26/08/2017 21:15 68 90 26/08/2017 21:00 26/08/2017 21:15 65 82
26/08/2017 21:15 26/08/2017 21:30 70 88 26/08/2017 21:15 26/08/2017 21:30 61 84 26/08/2017 21:15 26/08/2017 21:30 68 89 26/08/2017 21:15 26/08/2017 21:30 62 82
26/08/2017 21:30 26/08/2017 21:45 66 89 26/08/2017 21:30 26/08/2017 21:45 58 81 26/08/2017 21:30 26/08/2017 21:45 66 87 26/08/2017 21:30 26/08/2017 21:45 63 83
26/08/2017 21:45 26/08/2017 22:00 69 88 26/08/2017 21:45 26/08/2017 22:00 60 84 26/08/2017 21:45 26/08/2017 22:00 67 89 26/08/2017 21:45 26/08/2017 22:00 64 84
26/08/2017 22:00 26/08/2017 22:15 72 91 26/08/2017 22:00 26/08/2017 22:15 62 84 26/08/2017 22:00 26/08/2017 22:15 71 90 26/08/2017 22:00 26/08/2017 22:15 61 83
26/08/2017 22:15 26/08/2017 22:30 75 90 26/08/2017 22:15 26/08/2017 22:30 63 83 26/08/2017 22:15 26/08/2017 22:30 72 89 26/08/2017 22:15 26/08/2017 22:30 64 83
26/08/2017 22:30 26/08/2017 22:45 76 87 26/08/2017 22:30 26/08/2017 22:45 64 83 26/08/2017 22:30 26/08/2017 22:45 73 89 26/08/2017 22:30 26/08/2017 22:45 64 81
26/08/2017 22:45 26/08/2017 23:00 75 88 26/08/2017 22:45 26/08/2017 23:00 62 80 26/08/2017 22:45 26/08/2017 23:00 72 87 26/08/2017 22:45 26/08/2017 23:00 63 79
Three Spires Acoustics CH/NMCR/2017/27 SW4 & House of Common 2017- Noise Management Compliance Report
14
Table 4 SW4 Sunday 27th August 2017- External Monitoring Results Table
Hospice Report CC WEST Report Windmill Report 94CC NORTH Report
Start Stop LAeq LCeq Start Stop LAeq LCeq Start Stop LAeq LCeq Start Stop LAeq LCeq
27/08/2017 11:15 27/08/2017 11:30 61.02 74
27/08/2017 11:30 27/08/2017 11:45 62.09 81 27/08/2017 11:30 27/08/2017 11:45 60 84 27/08/2017 11:30 27/08/2017 11:45 59 75
27/08/2017 11:45 27/08/2017 12:00 65.05 85 27/08/2017 11:45 27/08/2017 12:00 57 82 27/08/2017 11:45 27/08/2017 12:00 62 87 27/08/2017 11:45 27/08/2017 12:00 61 80
27/08/2017 12:00 27/08/2017 12:15 64.61 85 27/08/2017 12:00 27/08/2017 12:15 56 81 27/08/2017 12:00 27/08/2017 12:15 63 88 27/08/2017 12:00 27/08/2017 12:15 59 78
27/08/2017 12:15 27/08/2017 12:30 69.01 85 27/08/2017 12:15 27/08/2017 12:30 57 82 27/08/2017 12:15 27/08/2017 12:30 64 87 27/08/2017 12:15 27/08/2017 12:30 59 79
27/08/2017 12:30 27/08/2017 12:45 64.81 85 27/08/2017 12:30 27/08/2017 12:45 56 81 27/08/2017 12:30 27/08/2017 12:45 63 87 27/08/2017 12:30 27/08/2017 12:45 61 77
27/08/2017 12:45 27/08/2017 13:00 64.23 83 27/08/2017 12:45 27/08/2017 13:00 57 78 27/08/2017 12:45 27/08/2017 13:00 63 87 27/08/2017 12:45 27/08/2017 13:00 61 76
27/08/2017 13:00 27/08/2017 13:15 65.42 84 27/08/2017 13:00 27/08/2017 13:15 54 77 27/08/2017 13:00 27/08/2017 13:15 63 86 27/08/2017 13:00 27/08/2017 13:15 59 77
27/08/2017 13:15 27/08/2017 13:30 66.45 84 27/08/2017 13:15 27/08/2017 13:30 54 78 27/08/2017 13:15 27/08/2017 13:30 64 87 27/08/2017 13:15 27/08/2017 13:30 61 78
27/08/2017 13:30 27/08/2017 13:45 66.8 84 27/08/2017 13:30 27/08/2017 13:45 56 79 27/08/2017 13:30 27/08/2017 13:45 64 87 27/08/2017 13:30 27/08/2017 13:45 62 80
27/08/2017 13:45 27/08/2017 14:00 66.89 84 27/08/2017 13:45 27/08/2017 14:00 54 79 27/08/2017 13:45 27/08/2017 14:00 64 86 27/08/2017 13:45 27/08/2017 14:00 63 79
27/08/2017 14:00 27/08/2017 14:15 66.47 85 27/08/2017 14:00 27/08/2017 14:15 56 82 27/08/2017 14:00 27/08/2017 14:15 64 88 27/08/2017 14:00 27/08/2017 14:15 61 80
27/08/2017 14:15 27/08/2017 14:30 66.59 86 27/08/2017 14:15 27/08/2017 14:30 56 81 27/08/2017 14:15 27/08/2017 14:30 65 88 27/08/2017 14:15 27/08/2017 14:30 61 80
27/08/2017 14:30 27/08/2017 14:45 67.98 86 27/08/2017 14:30 27/08/2017 14:45 58 82 27/08/2017 14:30 27/08/2017 14:45 66 89 27/08/2017 14:30 27/08/2017 14:45 60 81
27/08/2017 14:45 27/08/2017 15:00 67.02 87 27/08/2017 14:45 27/08/2017 15:00 56 82 27/08/2017 14:45 27/08/2017 15:00 64 87 27/08/2017 14:45 27/08/2017 15:00 61 81
27/08/2017 15:00 27/08/2017 15:15 66.28 85 27/08/2017 15:00 27/08/2017 15:15 56 80 27/08/2017 15:00 27/08/2017 15:15 63 87 27/08/2017 15:00 27/08/2017 15:15 61 80
27/08/2017 15:15 27/08/2017 15:30 67.24 85 27/08/2017 15:15 27/08/2017 15:30 55 79 27/08/2017 15:15 27/08/2017 15:30 64 87 27/08/2017 15:15 27/08/2017 15:30 61 81
27/08/2017 15:30 27/08/2017 15:45 68.04 86 27/08/2017 15:30 27/08/2017 15:45 56 79 27/08/2017 15:30 27/08/2017 15:45 65 86 27/08/2017 15:30 27/08/2017 15:45 61 81
27/08/2017 15:45 27/08/2017 16:00 69.1 85 27/08/2017 15:45 27/08/2017 16:00 59 81 27/08/2017 15:45 27/08/2017 16:00 66 87 27/08/2017 15:45 27/08/2017 16:00 65 82
27/08/2017 16:00 27/08/2017 16:15 67.52 86 27/08/2017 16:00 27/08/2017 16:15 57 79 27/08/2017 16:00 27/08/2017 16:15 65 86 27/08/2017 16:00 27/08/2017 16:15 62 80
27/08/2017 16:15 27/08/2017 16:30 68.13 86 27/08/2017 16:15 27/08/2017 16:30 57 78 27/08/2017 16:15 27/08/2017 16:30 65 86 27/08/2017 16:15 27/08/2017 16:30 62 81
27/08/2017 16:30 27/08/2017 16:45 67.7 87 27/08/2017 16:30 27/08/2017 16:45 57 78 27/08/2017 16:30 27/08/2017 16:45 64 86 27/08/2017 16:30 27/08/2017 16:45 60 80
27/08/2017 16:45 27/08/2017 17:00 68.34 87 27/08/2017 16:45 27/08/2017 17:00 56 79 27/08/2017 16:45 27/08/2017 17:00 65 86 27/08/2017 16:45 27/08/2017 17:00 62 80
27/08/2017 17:00 27/08/2017 17:15 68.09 88 27/08/2017 17:00 27/08/2017 17:15 58 83 27/08/2017 17:00 27/08/2017 17:15 66 88 27/08/2017 17:00 27/08/2017 17:15 61 81
27/08/2017 17:15 27/08/2017 17:30 69.15 89 27/08/2017 17:15 27/08/2017 17:30 58 82 27/08/2017 17:15 27/08/2017 17:30 66 88 27/08/2017 17:15 27/08/2017 17:30 62 80
27/08/2017 17:30 27/08/2017 17:45 68.58 88 27/08/2017 17:30 27/08/2017 17:45 59 81 27/08/2017 17:30 27/08/2017 17:45 67 89 27/08/2017 17:30 27/08/2017 17:45 60 81
27/08/2017 17:45 27/08/2017 18:00 69.03 90 27/08/2017 17:45 27/08/2017 18:00 59 83 27/08/2017 17:45 27/08/2017 18:00 67 90 27/08/2017 17:45 27/08/2017 18:00 63 81
27/08/2017 18:00 27/08/2017 18:15 67.89 89 27/08/2017 18:00 27/08/2017 18:15 61 83 27/08/2017 18:00 27/08/2017 18:15 68 91 27/08/2017 18:00 27/08/2017 18:15 64 85
27/08/2017 18:15 27/08/2017 18:30 65.69 89 27/08/2017 18:15 27/08/2017 18:30 59 81 27/08/2017 18:15 27/08/2017 18:30 67 91 27/08/2017 18:15 27/08/2017 18:30 63 84
27/08/2017 18:30 27/08/2017 18:45 70.68 90 27/08/2017 18:30 27/08/2017 18:45 59 82 27/08/2017 18:30 27/08/2017 18:45 67 90 27/08/2017 18:30 27/08/2017 18:45 63 84
27/08/2017 18:45 27/08/2017 19:00 68.56 87 27/08/2017 18:45 27/08/2017 19:00 61 82 27/08/2017 18:45 27/08/2017 19:00 68 90 27/08/2017 18:45 27/08/2017 19:00 65 84
27/08/2017 19:00 27/08/2017 19:15 68.72 88 27/08/2017 19:00 27/08/2017 19:15 61 83 27/08/2017 19:00 27/08/2017 19:15 68 89 27/08/2017 19:00 27/08/2017 19:15 65 84
27/08/2017 19:15 27/08/2017 19:30 68.77 88 27/08/2017 19:15 27/08/2017 19:30 60 82 27/08/2017 19:15 27/08/2017 19:30 68 88 27/08/2017 19:15 27/08/2017 19:30 63 83
27/08/2017 19:30 27/08/2017 19:45 65.69 85 27/08/2017 19:30 27/08/2017 19:45 59 81 27/08/2017 19:30 27/08/2017 19:45 66 87 27/08/2017 19:30 27/08/2017 19:45 63 83
27/08/2017 19:45 27/08/2017 20:00 67.87 87 27/08/2017 19:45 27/08/2017 20:00 60 84 27/08/2017 19:45 27/08/2017 20:00 67 89 27/08/2017 19:45 27/08/2017 20:00 63 85
27/08/2017 20:00 27/08/2017 20:15 68.4 87 27/08/2017 20:00 27/08/2017 20:15 60 83 27/08/2017 20:00 27/08/2017 20:15 67 88 27/08/2017 20:00 27/08/2017 20:15 63 85
27/08/2017 20:15 27/08/2017 20:30 68.24 88 27/08/2017 20:15 27/08/2017 20:30 59 82 27/08/2017 20:15 27/08/2017 20:30 65 88 27/08/2017 20:15 27/08/2017 20:30 64 85
27/08/2017 20:30 27/08/2017 20:45 68.96 87 27/08/2017 20:30 27/08/2017 20:45 57 79 27/08/2017 20:30 27/08/2017 20:45 64 86 27/08/2017 20:30 27/08/2017 20:45 64 85
27/08/2017 20:45 27/08/2017 21:00 66.09 86 27/08/2017 20:45 27/08/2017 21:00 59 79 27/08/2017 20:45 27/08/2017 21:00 64 86 27/08/2017 20:45 27/08/2017 21:00 65 85
27/08/2017 21:00 27/08/2017 21:15 70.66 89 27/08/2017 21:00 27/08/2017 21:15 60 86 27/08/2017 21:00 27/08/2017 21:15 67 90 27/08/2017 21:00 27/08/2017 21:15 67 86
27/08/2017 21:15 27/08/2017 21:30 71 89 27/08/2017 21:15 27/08/2017 21:30 59 83 27/08/2017 21:15 27/08/2017 21:30 68 88 27/08/2017 21:15 27/08/2017 21:30 64 85
27/08/2017 21:30 27/08/2017 21:45 71.34 90 27/08/2017 21:30 27/08/2017 21:45 57 82 27/08/2017 21:30 27/08/2017 21:45 67 88 27/08/2017 21:30 27/08/2017 21:45 64 86
27/08/2017 21:45 27/08/2017 22:00 72.59 91 27/08/2017 21:45 27/08/2017 22:00 58 82 27/08/2017 21:45 27/08/2017 22:00 68 89 27/08/2017 21:45 27/08/2017 22:00 64 85
27/08/2017 22:00 27/08/2017 22:15 72.6 90 27/08/2017 22:00 27/08/2017 22:15 57 81 27/08/2017 22:00 27/08/2017 22:15 68 88 27/08/2017 22:00 27/08/2017 22:15 62 83
27/08/2017 22:15 27/08/2017 22:30 72.68 89 27/08/2017 22:15 27/08/2017 22:30 58 80 27/08/2017 22:15 27/08/2017 22:30 68 87 27/08/2017 22:15 27/08/2017 22:30 63 83
27/08/2017 22:30 27/08/2017 22:32 63.15 73 27/08/2017 22:30 27/08/2017 22:32 55 69 27/08/2017 22:30 27/08/2017 22:32 63 72 27/08/2017 22:30 27/08/2017 22:45 63 71
Three Spires Acoustics CH/NMCR/2017/27 SW4 & House of Common 2017- Noise Management Compliance Report
15
Table 5 House of Common Monday 28th August 2017- External Monitoring Results Table
Hospice Report CC WEST Report Windmill Report 94CC NORTH Report
Start Stop LAeq LCeq Start Stop LAeq LCeq Start Stop LAeq LCeq Start Stop LAeq LCeq
28/08/2017 11:15 28/08/2017 12:30 61 73 28/08/2017 11:15 28/08/2017 12:30 54 66 28/08/2017 11:15 28/08/2017 11:29 61 72
28/08/2017 11:30 28/08/2017 12:45 62 73 28/08/2017 11:30 28/08/2017 12:45 55 66 28/08/2017 11:30 28/08/2017 11:45 61 71
28/08/2017 11:45 28/08/2017 13:00 62 73 28/08/2017 11:45 28/08/2017 13:00 57 68 28/08/2017 11:52 28/08/2017 12:00 57 71 28/08/2017 11:45 28/08/2017 12:00 61 72
28/08/2017 12:00 28/08/2017 13:15 65 77 28/08/2017 12:00 28/08/2017 13:15 56 68 28/08/2017 12:00 28/08/2017 12:15 59 77 28/08/2017 12:00 28/08/2017 12:15 60 73
28/08/2017 12:15 28/08/2017 13:30 64 80 28/08/2017 12:15 28/08/2017 13:30 54 70 28/08/2017 12:15 28/08/2017 12:30 59 80 28/08/2017 12:15 28/08/2017 12:30 61 74
28/08/2017 12:30 28/08/2017 13:45 65 82 28/08/2017 12:30 28/08/2017 13:45 54 74 28/08/2017 12:30 28/08/2017 12:45 58 81 28/08/2017 12:30 28/08/2017 12:45 64 75
28/08/2017 12:45 28/08/2017 14:00 65 82 28/08/2017 12:45 28/08/2017 14:00 54 74 28/08/2017 12:45 28/08/2017 13:00 60 81 28/08/2017 12:45 28/08/2017 13:00 63 76
28/08/2017 13:00 28/08/2017 14:15 67 82 28/08/2017 13:00 28/08/2017 14:15 54 75 28/08/2017 13:00 28/08/2017 13:15 61 84 28/08/2017 13:00 28/08/2017 13:15 64 76
28/08/2017 13:15 28/08/2017 14:30 68 82 28/08/2017 13:15 28/08/2017 14:30 56 74 28/08/2017 13:15 28/08/2017 13:30 62 83 28/08/2017 13:15 28/08/2017 13:30 62 75
28/08/2017 13:30 28/08/2017 14:45 67 82 28/08/2017 13:30 28/08/2017 14:45 55 74 28/08/2017 13:30 28/08/2017 13:45 62 83 28/08/2017 13:30 28/08/2017 13:45 62 76
28/08/2017 13:45 28/08/2017 15:00 66 80 28/08/2017 13:45 28/08/2017 15:00 55 72 28/08/2017 13:45 28/08/2017 14:00 60 82 28/08/2017 13:45 28/08/2017 14:00 64 73
28/08/2017 14:00 28/08/2017 15:15 64 80 28/08/2017 14:00 28/08/2017 15:15 55 71 28/08/2017 14:00 28/08/2017 14:15 60 82 28/08/2017 14:00 28/08/2017 14:15 68 74
28/08/2017 14:15 28/08/2017 15:30 66 83 28/08/2017 14:15 28/08/2017 15:30 54 72 28/08/2017 14:15 28/08/2017 14:30 61 84 28/08/2017 14:15 28/08/2017 14:30 68 75
28/08/2017 14:30 28/08/2017 15:45 66 81 28/08/2017 14:30 28/08/2017 15:45 54 73 28/08/2017 14:30 28/08/2017 14:45 62 82 28/08/2017 14:30 28/08/2017 14:45 68 75
28/08/2017 14:45 28/08/2017 16:00 63 77 28/08/2017 14:45 28/08/2017 16:00 53 68 28/08/2017 14:45 28/08/2017 15:00 59 78 28/08/2017 14:45 28/08/2017 15:00 69 74
28/08/2017 15:00 28/08/2017 16:15 64 77 28/08/2017 15:00 28/08/2017 16:15 49 66 28/08/2017 15:00 28/08/2017 15:15 57 77 28/08/2017 15:00 28/08/2017 15:15 67 73
28/08/2017 15:15 28/08/2017 16:30 70 82 28/08/2017 15:15 28/08/2017 16:30 54 70 28/08/2017 15:15 28/08/2017 15:30 62 80 28/08/2017 15:15 28/08/2017 15:30 67 76
28/08/2017 15:30 28/08/2017 16:45 72 83 28/08/2017 15:30 28/08/2017 16:45 55 71 28/08/2017 15:30 28/08/2017 15:45 64 82 28/08/2017 15:30 28/08/2017 15:45 66 75
28/08/2017 15:45 28/08/2017 17:00 71 82 28/08/2017 15:45 28/08/2017 17:00 54 70 28/08/2017 15:45 28/08/2017 16:00 64 81 28/08/2017 15:45 28/08/2017 16:00 71 76
28/08/2017 16:00 28/08/2017 17:15 65 79 28/08/2017 16:00 28/08/2017 17:15 51 66 28/08/2017 16:00 28/08/2017 16:15 59 78 28/08/2017 16:00 28/08/2017 16:15 66 72
28/08/2017 16:15 28/08/2017 17:30 67 83 28/08/2017 16:15 28/08/2017 17:30 51 70 28/08/2017 16:15 28/08/2017 16:30 62 82 28/08/2017 16:15 28/08/2017 16:30 68 74
28/08/2017 16:30 28/08/2017 17:45 67 83 28/08/2017 16:30 28/08/2017 17:45 52 71 28/08/2017 16:30 28/08/2017 16:45 63 83 28/08/2017 16:30 28/08/2017 16:45 67 74
28/08/2017 16:45 28/08/2017 18:00 64 81 28/08/2017 16:45 28/08/2017 18:00 56 68 28/08/2017 16:45 28/08/2017 17:00 61 82 28/08/2017 16:45 28/08/2017 17:00 67 74
28/08/2017 17:00 28/08/2017 18:15 70 84 28/08/2017 17:00 28/08/2017 18:15 52 73 28/08/2017 17:00 28/08/2017 17:15 64 85 28/08/2017 17:00 28/08/2017 17:15 66 76
28/08/2017 17:15 28/08/2017 18:30 71 83 28/08/2017 17:15 28/08/2017 18:30 53 74 28/08/2017 17:15 28/08/2017 17:30 64 84 28/08/2017 17:15 28/08/2017 17:30 65 76
28/08/2017 17:30 28/08/2017 18:45 72 85 28/08/2017 17:30 28/08/2017 18:45 55 75 28/08/2017 17:30 28/08/2017 17:45 66 85 28/08/2017 17:30 28/08/2017 17:45 64 78
28/08/2017 17:45 28/08/2017 19:00 67 84 28/08/2017 17:45 28/08/2017 19:00 52 70 28/08/2017 17:45 28/08/2017 18:00 63 86 28/08/2017 17:45 28/08/2017 18:00 65 74
28/08/2017 18:00 28/08/2017 19:15 64 83 28/08/2017 18:00 28/08/2017 19:15 55 69 28/08/2017 18:00 28/08/2017 18:15 61 83 28/08/2017 18:00 28/08/2017 18:15 66 74
28/08/2017 18:15 28/08/2017 19:30 72 88 28/08/2017 18:15 28/08/2017 19:30 53 74 28/08/2017 18:15 28/08/2017 18:30 65 87 28/08/2017 18:15 28/08/2017 18:30 62 77
28/08/2017 18:30 28/08/2017 19:45 73 87 28/08/2017 18:30 28/08/2017 19:45 53 70 28/08/2017 18:30 28/08/2017 18:45 65 85 28/08/2017 18:30 28/08/2017 18:45 61 76
28/08/2017 18:45 28/08/2017 20:00 73 86 28/08/2017 18:45 28/08/2017 20:00 53 69 28/08/2017 18:45 28/08/2017 19:00 65 82 28/08/2017 18:45 28/08/2017 19:00 59 75
28/08/2017 19:00 28/08/2017 20:15 73 86 28/08/2017 19:00 28/08/2017 20:15 57 69 28/08/2017 19:00 28/08/2017 19:15 66 83 28/08/2017 19:00 28/08/2017 19:15 59 74
28/08/2017 19:15 28/08/2017 20:30 70 84 28/08/2017 19:15 28/08/2017 20:30 55 71 28/08/2017 19:15 28/08/2017 19:30 62 83 28/08/2017 19:15 28/08/2017 19:30 61 75
28/08/2017 19:30 28/08/2017 20:45 69 84 28/08/2017 19:30 28/08/2017 20:45 56 72 28/08/2017 19:30 28/08/2017 19:45 63 84 28/08/2017 19:30 28/08/2017 19:45 63 76
28/08/2017 19:45 28/08/2017 21:00 70 84 28/08/2017 19:45 28/08/2017 21:00 52 72 28/08/2017 19:45 28/08/2017 20:00 63 83 28/08/2017 19:45 28/08/2017 20:00 62 75
28/08/2017 20:00 28/08/2017 21:15 63 77 28/08/2017 20:00 28/08/2017 21:15 54 67 28/08/2017 20:00 28/08/2017 20:15 59 77 28/08/2017 20:00 28/08/2017 20:15 60 72
28/08/2017 20:15 28/08/2017 21:30 72 84 28/08/2017 20:15 28/08/2017 21:30 54 73 28/08/2017 20:15 28/08/2017 20:30 65 82 28/08/2017 20:15 28/08/2017 20:30 62 76
28/08/2017 20:30 28/08/2017 21:45 72 84 28/08/2017 20:30 28/08/2017 21:45 61 75 28/08/2017 20:30 28/08/2017 20:45 66 83 28/08/2017 20:30 28/08/2017 20:45 60 76
28/08/2017 20:45 28/08/2017 22:00 72 84 28/08/2017 20:45 28/08/2017 22:00 54 75 28/08/2017 20:45 28/08/2017 21:00 64 83 28/08/2017 20:45 28/08/2017 21:00 60 78
28/08/2017 21:00 28/08/2017 22:15 72 84 28/08/2017 21:00 28/08/2017 22:15 51 75 28/08/2017 21:00 28/08/2017 21:15 64 84 28/08/2017 21:00 28/08/2017 21:15 59 77
28/08/2017 21:15 28/08/2017 22:30 72 83 28/08/2017 21:15 28/08/2017 22:30 53 75 28/08/2017 21:15 28/08/2017 21:30 65 83 28/08/2017 21:15 28/08/2017 21:30 59 75
28/08/2017 21:30 28/08/2017 22:45 71 84 28/08/2017 21:30 28/08/2017 22:45 53 75 28/08/2017 21:30 28/08/2017 21:45 64 83 28/08/2017 21:30 28/08/2017 21:45 60 76
28/08/2017 21:45 28/08/2017 23:00 72 83 28/08/2017 21:45 28/08/2017 23:00 50 74 28/08/2017 21:45 28/08/2017 21:57 66 83 28/08/2017 21:45 28/08/2017 22:00 63 76
Three Spires Acoustics CH/NMCR/2017/27 SW4 & House of Common 2017- Noise Management Compliance Report
16
: Complaints Google Map
Figure 10 Complaints Google Map
Three Spires Acoustics CH/NMCR/2017/27 SW4 & House of Common 2017- Noise Management Compliance Report
17
: Weather Data
Figure 11 Wind Speed & Direction 26th to 28th August 2017- source www.wunderground.com
Three Spires Acoustics CH/NMCR/2017/27 SW4 & House of Common 2017- Noise Management Compliance Report
18
Glossary of Terms
Noise Noise is defined as sound unwanted at the point of reception. The range of audible sound is from 0 dB to 140
dB. The frequency response of the ear is usually taken to be about 18 Hz (number of oscillations per second) to
18000 Hz. The ear does not respond equally to different frequencies at the same level. It is more sensitive in
the mid-frequency range than the lower and higher frequencies and because of this, the low and high
frequency components of a sound are reduced in importance by applying a weighting (filtering) circuit to the
noise measuring instrument. The weighting which is most widely used and which correlates best with
subjective response to noise is the dB(A) weighting. This is an internationally accepted standard for noise
measurements.
For variable noise sources such as traffic, a difference of 3 dB(A) is just distinguishable. In addition, a doubling
of a noise source would increase the overall noise by 3 dB(A). For example, if one item of machinery results in
noise levels of 30 dB(A) at 10 m, then two identical items of machinery adjacent to one another would result in
noise levels of 33 dB(A) at 10 m. The ‘loudness’ of a noise is a purely subjective parameter but it is generally
accepted that an increase/decrease of 10 dB(A) corresponds to a doubling/halving in perceived loudness.
External noise levels are rarely steady but rise and fall according to activities within an area. In an attempt to
produce a figure that relates this variable noise level to subjective response, a number of noise indices have
been developed. These include:
LAmax noise level: This is the maximum noise level recorded over the measurement period.
LAeq noise level: This is the ‘equivalent continuous A-weighted sound pressure level, in decibels’ and is defined in British Standard 7445 (BS 7445) [ ] as the ‘value of the A-weighted sound pressure level of a continuous, steady sound that, within a specified time interval, T, has the same mean square sound pressure as a sound under consideration whose level varies with time’. It is a unit commonly used to describe construction noise and noise from industrial premises and is the most suitable unit for the description of other forms of environmental noise. In more straightforward terms, it is a measure of energy within the varying noise. It is also the unit best suited to assessing community response.
Music Noise Level (MNL) : the LAeq of music noise measured at a particular location.
LA10 noise level: This is the noise level that is exceeded for 10% of the measurement period and gives an indication of the noisier levels. It is a unit that has been used over many years for the measurement and assessment of road traffic noise.
LA90 noise level: This is the noise level that is exceeded for 90% of the measurement period and gives an indication of the noise level during quieter periods. It is often referred to as the background noise level and is used in the assessment of disturbance from industrial noise.
Hz (Hertz): The tonal quality of a sound is described and measured in terms of the frequency content and is commonly expressed as octave or third octave bands, the latter being the division of the octave bands into three for finer analysis, across the frequency spectrum. The smaller the octave band or third octave band centre frequency number defined in terms of Hz, the lower the sound. For example 63 Hz is lower than 500 Hz and is perceived as a deeper sound. The attenuation due to air absorption and natural barriers increases with frequency i.e. low frequencies are always the most difficult to control
Three Spires Acoustics CH/NMCR/2017/27 SW4 & House of Common 2017- Noise Management Compliance Report
19
An indication of noise levels and pitches is provided in Appendix A1.1 and A1.2 of Building Bulletin 93 ‘Acoustic
Design of Schools: A Design Guide’, 2003 (BB 93). These are reproduced in Figures A1 and A2 below:
Typical sound pressure levels