UTRAN
Hardware ManualNode B
HWMN: NodeB (Platform 1)
A50016-G5000-G225-prelim-7631 ND-57315-706 (E)-prelim
A50016-G5000-G225-1-7631ND-57315-706 (E)-01
Trademarks:
All designations used in this document can be trademarks, the use of which by third parties
for their own purposes could violate the rights of their owners.
Copyright (C) Siemens AG / NEC Corporation 2005.
Issued by: Siemens AG, Communications, Hofmannstraße 51, 81359 München, Germany and NEC Corporation, 7-1, Shiba 5-chome, Minato-ku, Tokyo, Japan
Technical modifications possible. Technical specifications and features are binding only insofar as they are specifically and expressly agreed upon in a written contract.
A50016-G5000-G225-1-7631ND-57315-706 (E)-01 Precautions
PL 1 of 15
Precautions
To prevent potential injury or even death, this manual as well as the alert labels attached to the system, provide various safety precautions. It is imperative that all safety instructions in this manual and the alert labels be completely understood prior to performing any operations and/or maintenance work.
This manual is intended for the operation and maintenance personnel of the Node B system.
SAFETY INSTRUCTIONS
The “Safety Instructions” provides you safety instructions for the Node B. For other equipment, refer to the relevant manual of the particular equipment in question.
Definitions of Alert Categories
There are three Alert Categories.
DANGERThis symbol indicates that there is explicit life-threatening danger. Failure to obey this instruction could place you in an imminent danger of death or serious injury.
WARNINGThis symbol indicates an item that potentially endangers to your life. Failure to obey this instruction could lead to death or serious injury.
CAUTIONThis symbol indicates an item that potentially endangers your body and property. Failure to obey this instruction could cause injury to you, or damage to the equipment, components, and even the communication network or other property.
A50016-G5000-G225-1-7631ND-57315-706 (E)-01 Precautions
PL 2 of 15
List of Alert Labels
The following lists alert labels attached to the system. Locate the labels and be sure to follow the instructions on them.
CAUTION!
HOT SURFACEAvoid contact.
CAUTION!
(Location)Front of SCPA and MCPA
(Explanation)Do not touch the SCPA and MCPA which can heat up to a hightemperature during operation. Touching these equipment can causeserius burns. Be sure to wear gloves or adequate protective gearswhen handling these parts.
ANT0 ANT1-48v present
(Location)Front of DUAMCO(Explanation)
Pay full attention during operation since -48V DC current is outputto the connector ANT0 and ANT1 in front of DUAMCO.
A50016-G5000-G225-1-7631ND-57315-706 (E)-01 Precautions
PL 3 of 15
List of Safety Instructions
When you find a safety instruction in this manual, be sure to read the instruction before starting the work.
The safety instructions, especially regarding death or injury in this manual are listed below, by their alert categories.
• Alert category: Danger
DANGERImportant Notice on Product SafetyDANGER - RISK OF ELECTRICAL SHOCK OR DEATH - FOLLOW ALL INSTALLATION INSTRUCTIONS.The system complies with the standard EN 60950 / IEC 60950. All equipment connected to the system must comply with the applicable safety standards.Hazardous voltages are present at the AC power supply lines in this electrical equipment. Some components may also have high operating temperatures.Failure to observe and follow all installation and safety instructions can result in serious personal injury or property damage.Therefore, only trained and qualified personnel may install and maintain the system.
The same text in German:Wichtiger Hinweis zur ProduktsicherheitLEBENSGEFAHR - BEACHTEN SIE ALLE INSTALLATIONSHINWEISE.Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Alle an das System angeschlossenen Geräte müssen die zutreffenden Sicherheitsbestimmungen erfüllen.In diesen Anlagen stehen die Netzversorgungsleitungen unter gefährlicher Spannung. Einige Komponenten können auch eine hohe Betriebstemperatur aufweisen.Nichtbeachtung der Installations- und Sicherheitshinweise kann zu schweren Körperverletzungen oder Sachschäden führen.Deshalb darf nur geschultes und qualifiziertes Personal das System installieren und warten.
A50016-G5000-G225-1-7631ND-57315-706 (E)-01 Precautions
PL 4 of 15
• Alert category: Caution
CAUTIONThis equipment has been tested and found to comply with EN 55022. Its class of conformity is defined in table A30808-X3247-X910-*-7618, which is shipped with each product. This class also corresponds to the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the relevant standards referenced in the manual "Guide to Documentation", may cause harmful interference to radio communications.For system installations it is strictly required to choose all installation sites according to national and local requirements concerning construction rules and static load capacities of buildings and roofs.For all sites, in particular in residential areas it is mandatory to observe all respectively applicable electromagnetic field / force (EMF) limits. Otherwise harmful personal interference is possible.
A50016-G5000-G225-1-7631ND-57315-706 (E)-01 Precautions
PL 5 of 15
• Alert category: Caution (continued)
CAUTIONSafety instructions on the overall work:
• Before performing any operation and maintenance work, make sure that the working environment is safe.
• Before performing any operation and maintenance work, check the emergency exits are clear in case of an emergency situation.
• Before performing any operation and maintenance work, make sure sufficient safety instructions are given to the maintenance personnel.
• Never wear slippers during work.• Take care not to trip over cables, components, or tools during work.
Failure to do so could result in injury.• Take care that shirt sleeves and trousers are not caught in equipment
and/or machines during work. Failure to do so could cause an injury or other accident.
• Do not allow liquid, such as water, on system components or touch the system with wet hands. Moisture in the system can cause an electrical shock or a trouble to the system. If any liquid comes into contact with the system, immediately turn off the power of the affected components, and request repairs.
• Do not rework or disassemble system components. An electrical shock, fire or component and/or system failure could occur as a result.
A50016-G5000-G225-1-7631ND-57315-706 (E)-01 Precautions
PL 6 of 15
• Alert category: Caution (continued)
CAUTIONSafety instructions concerning handling tools and test equipment:
• Before connecting any electric tool to an AC outlet, be sure to check the voltage (100 V or 240 V) and frequency usable with the tool. Using an electric tool with the wrong voltage or frequency can result in an electrical shock or other accident.
• When using any electric tool, be sure to connect a ground wire to it. Using an electric tool without connecting it to ground can lead to an electrical shock.
• When an electric tool is being not used, be sure to unplug the power cable from the AC outlet. Failure to do so could cause an electrical shock or other accident.
• When using a crimping tool, be careful not to get your fingers caught in the jaws of the tool.
• When using any electric tool or crimping tool, be sure to observe the instructions given in the relevant instruction manuals.
Safety instructions for handling cards:• Wear thin cotton gloves when handling cards. Working with bare
hands can lead to an injury or accident.• Follow all instructions for handling the card being tested, the test
instrument, cables, and all other components properly in accordance with the instructions given in the relevant manuals.
A50016-G5000-G225-1-7631ND-57315-706 (E)-01 Precautions
PL 7 of 15
• Alert category: Caution (continued)
CAUTIONSafety instructions on high voltage and high current:
• Persons other than the maintenance personnel must not touch the Direct Current Power Distribution Board (DC-PDB). The DC-PDB carries high voltage and current. Touching it could result in an electrical shock or other accident.
• Do not touch those parts of the Node B that contains components with high voltage or current. Inadvertent contact with any of these components can cause injury, death, and/or damage to the system.
• Be sure to provide grounding where required. Failure to do so can result in system failure or electrical shock, especially if caused by the lightening.
• When measuring voltage or current, take adequate insulating measures, such as covering or winding the unnecessary parts of the measuring terminal and tools with insulating tape. Allowing the measuring terminal to touch another terminal, or a short-circuit caused by a tool could result in an lead to an electrical shock or other accident.
• Before making a connection to the DC-PDB, ensure that the power to the main circuit breaker is OFF. Making a connection to the DC-PDB when the power is ON can result in an electrical shock or other accident.
• Before making a cable connection, be sure to turn OFF the switch on the power distribution board. Otherwise, an electrical shock or other accident could occur.
• Before making a cable connection, confirm the electric polarity is correct. If the cable is connected to the wrong polarity, an electrical shock or other accident could occur.
Safety instructions when working up high or on a step ladder:• When working on a cable rack or running cables while on a step or
other ladder, watch your footing and be careful not to fall. Failure to take proper precautions could result in injury or other problems.
• When working on a cable rack or running cables up high, be careful not to drop any tools or components. Dropping a tool or a component can injure other personnel, or cause other troubles to the system.
A50016-G5000-G225-1-7631ND-57315-706 (E)-01 Precautions
PL 8 of 15
• Alert category: Caution (continued)
CAUTIONSafety instructions on high temperature:
• Do not touch the Single Carrier Power Amplifier (SCPA), Multi Carrier Power Amplifier (MCPA) and the Power Supply (PS) which can heat up to a high temperature during operation. Touching these equipment could result in an injury or other accident. Be sure to wear gloves or adequate protective gears when handling these parts.
Safety instructions on rotating parts:• Do not touch rotating parts such as fans, and do not remove the guard
while they are still rotating. Touching these rotating parts while they are still in motion rotating could result in an injury or other accident.
Safety instructions on heavy weight:• Use both hands to pull out the Duplex Amplifier Multi-Coupler
(DUAMCO), SCPA and MCPA. Pulling out heavy equipment such as these with only one hand could result in an injury or other accident.
A50016-G5000-G225-1-7631ND-57315-706 (E)-01 Precautions
PL 9 of 15
PRECAUTIONS FOR NORMAL SYSTEM OPERATION
The “Precautions for Normal System Operation” provides precautions against potential problems that could occur to the system. In order to maintain normal operation of the system, particular attention must be paid to each precaution prior to and during any operation and/or maintenance work.
Site Consideration
To maintain normal system operation, your site must always meet the requirements listed below.
(1) Temperature and humidity
• Make sure that the temperature and humidity levels are within the acceptable range: the temperature must be between -5 and 50°C and the humidity 20 and 95%. (There must be no condensation).
• Make sure that the site is not exposed to liquid such as water and oil.
• Make sure that the site is not exposed to direct sunlight nor placed near a flame or heating appliance like a stove.
(2) DustTo prevent a short circuit due to dust buildup, make sure that the site is kept clean and dust free.
(3) VibrationSince the system components are precision-engineered equipment and devices, make sure that the site is not subject to vibration.
(4) Heat dissipationProper air circulation is necessary to prevent the temperature from rising inside the system. Make sure that the vents of the system components are always kept clear.
(5) Static electricityBe sure to connect your wrist strap to the ground such as an Electrostatically Sensitive Devices (ESD) terminal.
A50016-G5000-G225-1-7631ND-57315-706 (E)-01 Precautions
PL 10 of 15
List of Precautions
The precautions are listed by the following working situations:
• When Operating the System
• When Handling Cards
• When Handling the Power Amplifiers
• When Handling the Power Supply
• When Handling Parts and Components
When Operating The System
• Keep the doors of the machine room closed during work. In a room with high humidity, vapor can condense on cards and shelves in the system, which can lead to a short-circuit or fire. Excessive dust can also cause a short-circuit or fire.
• If using air-conditioning, prevent water from ceiling or refrigerant pipes from dripping on cards and shelves in the system. If any component in the system becomes wet, this could result in a short-circuit or fire can occur.
• Keep the humidity in the machine room within the range of 20 to 95%, with no condensation.
• Do not leave foreign objects such as screws, wires, or pieces of metal, inside the racks, shelves, or terminal devices of the system. Such foreign object can damage the equipment or cause a short-circuit, subsequently resulting in a malfunction of the system or other problem.
• Wear antistatic shoes during the operation and maintenance work.
• Clean the filter on the fan at least every six months. If the filter is not kept properly cleaned, a short-circuit or fire can occur.
• When the system starts up, check that the transmission frequency is within the specified frequency range. If the transmission frequency is out of the specified frequency range, the equipment can be damaged or it can work improperly.
A50016-G5000-G225-1-7631ND-57315-706 (E)-01 Precautions
PL 11 of 15
When Handling Cards
• When inserting or removing a card of the system components, always wear thin cotton gloves and a grounded wrist strap to prevent static electricity. Electrostatic charge can damage the internal parts.
• Make sure that the switches and short plugs on the spare card are in the same condition as those on the card to be replaced.
Wear a pair of gloves.
Wear a wrist strap.
GND
wrist strap
To GND
0 1 2 3
ON
OFF
DIP switches
Rotary switch
Short plugs
A50016-G5000-G225-1-7631ND-57315-706 (E)-01 Precautions
PL 12 of 15
• Make sure the direction (top and bottom) of the spare card is correct. Do not force the card into the slot. Forcibly inserting a card in the wrong direction can damage it.
• Do not bend or twist the card. Bending or twisting the card can damage it and result in a malfunction.
• If a card is marked with a "!" label, be sure to turn the power switch of the card off before removing it.
Right Wrong
A50016-G5000-G225-1-7631ND-57315-706 (E)-01 Precautions
PL 13 of 15
When Handling The Power Amplifiers
• Use both hands to pull out the power amplifier unit (SCPA, MCPA, or DUAMCO) because of its heavy weight. Pull out the unit with both hands depicted as below. Pulling out the unit with only one hand can make you drop and a damage the unit.
When Handling The Power Supply
• The system components are kept in operation with the power supply turned on at all times. Make sure that no personnel except the system administrator is allowed to operate the power switch. If the power supply is interrupted, communications will be disrupted, and the unsaved data will be lost.
• Never turn the power switch of a card on and off, or insert or remove a fuse unless absolutely necessary. Be careful not to abruptly turn the power supply on and off.
• Normal operation of the system is not guaranteed when the input voltage is out of the prescribed range. The system operation is not guaranteed even when the voltage returns to a normal level once it has gone out of range. In this case, it will be necessary to reset the system.
GND
wrist strap
A50016-G5000-G225-1-7631ND-57315-706 (E)-01 Precautions
PL 14 of 15
When Handling Parts and Components
• Never swing a cable. Never forcibly wind a cable. Swinging or forcibly winding a cable can break the cable or damage its connector.
• Never wind an optical cable to form a loop with a diameter of 100 mm or less. To do so could break the optical cable.
• When making a connection with a cable conductor, be careful not to place the conductor in contact with another cable conductor. A short-circuit could result in a fire or other damage.
• Never remove the cap from an optical connector, except when attaching the connector. If an optical connector is damaged or contaminated with dust, this will disrupt communications error can occur.
• Never step on a battery. Stepping on a battery can cause the battery to leak.
• Use tools and components such as batteries and cables correctly, in accordance with the instructions given in the relevant manuals.
A50016-G5000-G225-1-7631ND-57315-706 (E)-01 Precautions
PL 15 of 15
DISPOSAL OF ELECTRICAL AND ELECTRONIC EQUIPMENT
All electrical and electronic products should be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities.
The correct disposal and separate collection of your old appliance will help prevent potential negative consequences for the environment and human health. It is a precondition for reuse and recycling of used electrical and electronic equipment.
For more detailed information about disposal of your old appliance, please contact your sales representative.
The statements quoted above are only fully valid for equipment which is installed in the countries of the European Union and is covered by the directive 2002/96/EC.
Countries outside the European Union may have other regulations regarding the disposal of electrical and electronic equipment.
A50016-G5000-G225-1-7631ND-57315-706 (E)-01 Preface
PR 1 of 1
Preface
This document is prepared as a standard edition that may include descriptions not applying to your system.
This document describes the standard hardware configuration of the Node B in the Wideband Code Division Multiple Access (W-CDMA) system.
This document comprises the following sections:
INTRODUCTIONDescribes the meaning of terms.
RACK/SHELTERDescribes the Node B rack and shelter.
SHELFDescribes the shelves.
CARDDescribes the cards.
TTADescribes the Tower Top Amplifier (TTA).
INTERFACE PORTDescribes the interface ports on the top of the Node B rack.
A50016-G5000-G225-1-7631ND-57315-706 (E)-01
DA 1 of 1
Reason for Update
Summary:
Preliminary edition
Details:
Issue History:
Chapter/Section Reason for Update
All Preliminary edition
Issue Number
Date of issue Reason for Update
prelim 10/2005 Preliminary edition
A50016-G5000-G225-1-7631ND-57315-706 (E)-01 Contents
CL 1 of 2
Contents
(*:REVISION)
TITLE INDEX NUMBER
SECTION 1INTRODUCTION
Meaning of Each Part of Hardware (NB-530) .................. INT-092-10000-11(E)-01
Meaning of Each Part of Hardware (NB-531) .................. INT-092-10010-11(E)-01
SECTION 2RACK/SHELTER
Dimensions of NB-530 Rack............................................ DDS-092-DIME0-11(E)-01
Dimensions of NB-531 Shelter ........................................ DDS-092-DIME1-11(E)-01
NB-530 Rack ................................................................... DDS-092-RACK0-11(E)-01
NB-531 Shelter ................................................................ DDS-092-SHEL0-11(E)-01
SECTION 3SHELF
A-SHF .............................................................................. DDS-092-ASHF0-11(E)-01
B-SHF .............................................................................. DDS-092-BSHF0-11(E)-01
T-SHF .............................................................................. DDS-092-TSHF0-11(E)-01
SECTION 4CARD
2.0M-HWY1 ..................................................................... DDS-092-HWY20-11(E)-01
AMP FAN ......................................................................... DDS-092-AMPFN-11(E)-01
AMP-SC........................................................................... DDS-092-AMPSC-11(E)-01
ASI ................................................................................... DDS-092-ASI00-11(E)-01
ATM.................................................................................. DDS-092-ATM00-11(E)-01
CHC ................................................................................. DDS-092-CHC00-11(E)-01
CLK.................................................................................. DDS-092-CLK00-11(E)-01
CP.................................................................................... DDS-092-CP000-11(E)-01
DUAMCO......................................................................... DDS-092-DUAMC-11(E)-01
EIU................................................................................... DDS-092-EIU00-11(E)-01
FAN.................................................................................. DDS-092-FAN00-11(E)-01
A50016-G5000-G225-1-7631ND-57315-706 (E)-01 Contents
CL 2 of 2
HWY-MON20 ................................................................... DDS-092-HWM20-11(E)-01
MCPA............................................................................... DDS-092-MCPA0-11(E)-01
PS1 .................................................................................. DDS-092-PS100-11(E)-01
PS2 .................................................................................. DDS-092-PS200-11(E)-01
REP ................................................................................. DDS-092-REP00-11(E)-01
RFSW .............................................................................. DDS-092-RFSW0-11(E)-01
SCPA ............................................................................... DDS-092-SCPA0-11(E)-01
SDM................................................................................. DDS-092-SDM00-11(E)-01
TRX.................................................................................. DDS-092-TRX00-11(E)-01
SECTION 5TTA
TTA .................................................................................. DDS-092-TTA00-11(E)-01
SECTION 6INTERFACE PORT
Control System Expansion Interface................................ DDS-092-CNTIF-11(E)-01
HWY Interface ................................................................. DDS-092-HWYIF-11(E)-01
PWR Interface ................................................................. DDS-092-PWRIF-11(E)-01
RF Interface ..................................................................... DDS-092-RFIF0-11(E)-01
RF System Expansion Interface ...................................... DDS-092-RFIF1-11(E)-01
Site Supervisory and Remote Control Interface .............. DDS-092-SSRIF-11(E)-01
TITLE INDEX NUMBER
A50016-G5000-G225-1-7631ND-57315-706 (E)-01
SECTION 1INTRODUCTION
A50016-G5000-G225-1-7631INT-092-10000-11 (E)-01 Meaning of Each Part of Hardware (NB-530)
INT-009-10000 1 of 2
Meaning of Each Part of Hardware (NB-530)
1. NODE B HARDWARE COMPOSITION
NB-530 hardware is composed of Racks, Shelves, Cards and TTAs.
Fig. 1 Hardware composition
Meanings of Rack, Shelf, Card, and TTA are as follows:
• Rack:Rack is the indoor equipment of Node B system. And rack can accommodate several shelves.Interface ports for external equipments are located on the top board of the rack.
RACK
Interface Port
SHELF
SHELF
SHELFCARD
TTA
( Outdoor )
CARD
CARD
( Indoor )
Suction port
Suction port
A50016-G5000-G225-1-7631INT-092-10000-11 (E)-01 Meaning of Each Part of Hardware (NB-530)
INT-009-10000 2 of 2
• Shelf:Shelf has several slots which can accommodate cards.
• Card:Card is a printed wiring board which accommodates electronic components. And card is the minimum unit of Node B function.
• TTA:TTA (Tower Top Amplifier) is the outdoor equipment of Node B system.
A50016-G5000-G225-1-7631INT-092-10010-11 (E)-01 Meaning of Each Part of Hardware (NB-531)
INT-009-10010 1 of 2
Meaning of Each Part of Hardware (NB-531)
1. NODE B HARDWARE COMPOSITION
NB-531 hardware is composed of Shelters, Shelves, Cards and TTAs.
Fig. 1 Hardware composition
Meanings of Shelter, Shelf, Card, and TTA are as follows:
• Shelter:
( Outdoor )
TTA
SHELF
Suction port
Suction port
SHELF
Rectfier
TransmissionEquipment
Battery
CARD
CARD
CARD
( Outdoor )
Interface Port
SHELTER
SHELF
A50016-G5000-G225-1-7631INT-092-10010-11 (E)-01 Meaning of Each Part of Hardware (NB-531)
INT-009-10010 2 of 2
Shelter is the outdoor equipment of Node B system. And shelter can accommodate several shelves.Interface ports for antenna and transmission are located on the left side of the shelter.
• Shelf:Shelf has several slots which can accommodate cards.
• Card:Card is a printed wiring board which accommodates electronic components. And card is the minimum unit of Node B function.
• TTA:TTA (Tower Top Amplifier) is the outdoor equipment of Node B system.
A50016-G5000-G225-1-7631ND-57315-706 (E)-01
SECTION 2RACK/SHELTER
A50016-G5000-G225-1-7631DDS-092-DIME0-11 (E)-01 Dimensions of NB-530 Rack
DDS-092-DIME0 1 of 2
Dimensions of NB-530 Rack
1. DIMENSIONS
Fig. 1 Dimension of Node B (Front and Side)
Front View Side View600 600
1800
Unit: mm
A50016-G5000-G225-1-7631DDS-092-DIME0-11 (E)-01 Dimensions of NB-530 Rack
DDS-092-DIME0 2 of 2
Fig. 2 Dimension of Node B (Top and Bottom)
Top View
600
600
Bottom View
486
434
Unit: mm
A50016-G5000-G225-1-7631DDS-092-DIME1-11 (E)-01 Dimensions of NB-531 Shelter
DDS-092-DIME1 1 of 2
Dimensions of NB-531 Shelter
1. DIMENSIONS
Fig. 1 Dimension of Node B (Front and Right side)
Right Side View
1900
1200600
1200
5060
1852
Unit: mm50.8 798
336.5
900
Front View
A50016-G5000-G225-1-7631DDS-092-DIME1-11 (E)-01 Dimensions of NB-531 Shelter
DDS-092-DIME1 2 of 2
Fig. 2 Dimension of Node B (Top and Bottom)
Top View
900
Unit: mm75
8750 750
Bottom View
A50016-G5000-G225-1-7631DDS-092-RACK0-11 (E)-01 NB-530 Rack
DDS-092-RACK0 1 of 2
NB-530 Rack
1. SHELF ACCOMMODATION
Fig. 1 Shelf accommodation
• A-SHF (Amplifier Shelf)
• B-SHF (Base Shelf)
• T-SHF (Transceiver Shelf)
Front View of Extension Rack
B-SHF( Cards are notmounted on theupper part )
Front View of Base Rack
A-SHF
B-SHF
T-SHF
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
A50016-G5000-G225-1-7631DDS-092-RACK0-11 (E)-01 NB-530 Rack
DDS-092-RACK0 2 of 2
2. INTERFACE PORT ACCOMMODATION
Fig. 2 Interface port accommodation
• Control System Expansion Interface
• HWY Interface
• PWR Interface
• RF Interface
• RF System Expansion Interface
• Site Supervisory and Remote Control Interface
RF System Expansion Interface
Control SystemExpansion Interface
Top View
RF Interface
HWY Interface
PWR Interface
Front
Site Supervisory andRemote Control Interface
A50016-G5000-G225-1-7631DDS-092-SHEL0-11 (E)-01 NB-531 Shelter
DDS-092-SHEL0 1 of 2
NB-531 Shelter
1. SHELF ACCOMMODATION
Fig. 1 Shelf accommodation
• A-SHF (Amplifier Shelf)
• B-SHF (Base Shelf)
• T-SHF (Transceiver Shelf)
Front View
B-SHF
T-SHF
A-SHF
Rectfier
Space forTransmission
Equipment(PASOLINK )
Battery
Battery
A50016-G5000-G225-1-7631DDS-092-SHEL0-11 (E)-01 NB-531 Shelter
DDS-092-SHEL0 2 of 2
2. INTERFACE PORT ACCOMMODATION
Fig. 2 Interface port accommodation
4
Node-B Transmission
1 1
3
2
2'6 5
4
Right Side View
3
RX
Sector 3
Sector 2
Sector 1
RF Interface HWY Interface
(site-dependent)
TX/RX
RX
RX
TX/RX
TX/RX
A50016-G5000-G225-1-7631ND-57315-706 (E)-01
SECTION 3SHELF
A50016-G5000-G225-1-7631DDS-092-ASHF0-11 (E)-01 A-SHF
DDS-092-ASHF0 1 of 1
A-SHF
1. CARD ACCOMMODATION
Fig. 1 Card accommodation (A-SHF)
Note: Slot number is used to specify the card position in the AP macro.
• AMP FAN (Amplifier Fan)
• AMP-SC (Amplifier Supervisory and Control)
• DUAMCO (Duplex Amplifier Multi-Coupler)
• MCPA (Multi Carrier Power Amplifier)
• SCPA (Single Carrier Power Amplifier)
Slotnumber
SCPA/MCPA
0
Suction Port
AMP|SC
Front View of Shelf
A M P F A N
SCPA/MCPA
1
SCPA/MCPA
2
SCPA/MCPA
3
SCPA/MCPA
4
SCPA/MCPA
5
DUAMCO 0 DUAMCO 2DUAMCO 1
0602 03 04 0500 01
A50016-G5000-G225-1-7631DDS-092-BSHF0-11 (E)-01 B-SHF
DDS-092-BSHF0 1 of 2
B-SHF
1. CARD ACCOMMODATAION
Fig. 1 Card accommodation (B-SHF)
Note: Slot number is used to specify the card position in the AP macro.
• 2.0M-HWY1 (2.0M Highway 1)
• ASI (ATM Shelf Interface)
• ATM (Asynchronous Transfer Mode)
• CHC (Channel Coding)
• CLK (Clock)
Suction Port
Front View of Shelf
PS1
0
PS1
1
ATM
N
ATM
E
CLK
E
CLK
N
CP
E
CP
N
SDM
E
SDM
N
EIU
HWY|
MON20
PS2
1
PS2
0
ASI
N
ASI
E
RFSW
CHC
6
REP
1
CHC
1
CHC
8
CHC
7
CHC
9
CHC
4
CHC
3
CHC
5
CHC
2
CHC
0
REP
0
TRX
2
TRX
E
TRX
1
TRX
3
RFSW
22 23 2421 25 2913 141211100907 0805 0604030201
10 11 1209 150807060504030201Slot
number
Slotnumber
2.0M|HWY1
2.0M|HWY1
0 1
A50016-G5000-G225-1-7631DDS-092-BSHF0-11 (E)-01 B-SHF
DDS-092-BSHF0 2 of 2
• CP (Central Processing)
• EIU (External Interface Unit)
• FAN (Fan)
• HWY-MON20 (Highway Monitor 2M)
• PS1 (Power Supply 1)
• PS2 (Power Supply 2)
• REP (Repeater)
• RFSW (Radio Frequency Switch)
• SDM (System Data Memory)
• TRX (Transmitter and Receiver)
A50016-G5000-G225-1-7631DDS-092-TSHF0-11 (E)-01 T-SHF
DDS-092-TSHF0 1 of 1
T-SHF
1. CARD ACCOMMODATION
Fig. 1 Card accommodation (T-SHF)
Note: Slot number is used to specify the card position in the AP macro.
• ASI (ATM Shelf Interface)
• CHC (Channel Coding)
• FAN (Fan)
• PS2 (Power Supply 2)
• REP (Repeater)
• TRX (Transmitter and Receiver)
Slotnumber
Front View of Shelf
PS2
1
PS2
0
ASI
N
ASI
E
RFSW
CHC
6
REP
1
CHC
1
CHC
8
CHC
7
CHC
9
CHC
4
CHC
3
CHC
5
CHC
2
CHC
0
REP
0
TRX
2
TRX
E
TRX
1
TRX
3
RFSW
22 23 2421 25 2913 141211100907 0805 0604030201
F A N
A50016-G5000-G225-1-7631ND-57315-706 (E)-01
SECTION 4CARD
A50016-G5000-G225-1-7631DDS-092-HWY20-11 (E)-01 2.0M-HWY1
DDS-092-HWY20 1 of 3
2.0M-HWY1
1. CARD LAYOUT
This card is used to connect the Node B with the RNC. The card is also used to process the inter-exchange control signal protocol on the 2M transfer circuit.
Fig. 1 Front view of 2.0M-HWY1
RESET
ETHER
ALMERR0
ACT
MT
FUNC
REC
USE
BLK
SEND
ERR1
Front View
ON
ACT LED (Green)
Card Ejector
Card Ejector
USE LED (Green)
RESET Button (Pushbutton switch)
ERR0 LED (Red)ERR1 LED (Red)
ALM LED (Red)
SEND LED (Green)REC LED (Green)BLK LED (Red)BLK Button (Pushbutton switch)
4-pole Switch
Connector for SIO communication
Connector for Ethernet communication
A50016-G5000-G225-1-7631DDS-092-HWY20-11 (E)-01 2.0M-HWY1
DDS-092-HWY20 2 of 3
Table 1 LED indicators and operation block (1/2)
State Display/Operation Description
ACT (Normal operation) LED (Green)
(Lighting condition)
- When being operated normally
(Lighting out condition)
- When alarm occurs
- When changed to blocked state
ALM (Alarm) LED (Red)
(Lighting condition)
- When internal hardware and firmware errors occur
(Lighting out condition)
- When resetting
ERR0 (Error) LED (Red)
(Lighting condition)
- When REC, ASI, or RAI of HWY signal received in line being used was detected
(Lighting out condition)
- When error condition above was eliminated
ERR1 (Error) LED (Red)
(Lighting condition)
- When error in establishing SSCOP link with Zone Center was detected
(Lighting out condition)
- When SSCOP link error was normally recovered
USE (Line state) LED (Green)
(Lighting condition)
- When FUNC SW is ON and VPI is allocated from API
(Lighting out condition)
- When FUNC SW is OFF and line is not used
- When FUNC SW is ON and VPI is allocated from API
A50016-G5000-G225-1-7631DDS-092-HWY20-11 (E)-01 2.0M-HWY1
DDS-092-HWY20 3 of 3
FUNC (Using line) DIP SW
Indicates use state of line.
(SW ON)
- Using line. Detects ERR 0.
(SW OFF)
- Using no line Detects no ERR 0.
SEND (Inter-station control
signal transmission)
LED(Green) - Lit for about 200ms when inter-station control signal was transmitted in ATM cell.
REC (Inter-station control signal
receive)LED(Green) - Lit for about 200ms when significant signal of inter-
station control signal was received in ATM cell.
BLK (Blocked)LED(Red)
(Lighting condition)
- When blocked
(Lighting out condition)
- When blocked state is released
Pushbutton switch Each time the pushbutton switch is pressed once, blocked status or unblocked status is alternatively repeated.
RESET (Reset) Pushbutton switchWhen the pushbutton is pressed, reset is executed in the card and the card is initialized. Reset holding time is about 10 sec.
Table 1 LED indicators and operation block (2/2)
State Display/Operation Description
A50016-G5000-G225-1-7631DDS-092-AMPFN-11 (E)-01 AMP FAN
DDS-092-AMPFN 1 of 1
AMP FAN
1. CARD LAYOUT
This card is used to cool the power amplifiers.
Fig. 1 Front view of AMP FAN
Table 1 LED indicators and operation block
State Display/Operation
Description
ALM (Alarm) LED (Red)
(Lighting condition)
- When error occurs in fan
- When the number of revolutions decreases
(Lighting out condition)
- When being operated normally
- When the power is OFF
ALM LED (Red)Screw Screw
FAN1 FAN2 FAN3 FAN4ALM AMP-FAN
Front View
A50016-G5000-G225-1-7631DDS-092-AMPSC-11 (E)-01 AMP-SC
DDS-092-AMPSC 1 of 3
AMP-SC
1. CARD LAYOUT
This card is used to monitor the cards mounted on the A-SHF.
Fig. 1 Front view of AMP-SC
Front View
Screw
ACT LED (Green)ALM LED (Red)ERR LED (Red)SEND LED (Green)REC LED (Green)
RESET Button (Pushbutton switch)
ON/OFF Switch
Screw
AMP-SC
ACTALMERR
SENDREC
RESET
ON
OFF
PS
A50016-G5000-G225-1-7631DDS-092-AMPSC-11 (E)-01 AMP-SC
DDS-092-AMPSC 2 of 3
Table 1 LED indicators and operation block (1/2)
State Display/Operation
Description
ACT (Normal operation) LED (Green)
(Lighting condition)
- When being operated normally
(Lighting out condition)
- When alarm occurs
- When resetting
- When the power is OFF
ALM (Alarm) LED (Red)
(Lighting condition)
- When error is detected in the internal circuit
(Lighting out condition)
- When resetting
- When the power is OFF
ERR (Error) LED (Red)
(Lighting condition)
- When parity error is detected in the received signal
- When carrier disconnect over 120 seconds is detected
(Lighting out condition)
- When recovery from the above error
SEND (Send) LED (Green)
(Lighting condition)
- When signal is sent to MDE
(Lighting out condition)
- When signal is not sent to MDE
REC (Receive) LED (Green)
(Lighting condition)
- When signal is received from MDE
(Lighting out condition)
- When signal is not received from MDE
A50016-G5000-G225-1-7631DDS-092-AMPSC-11 (E)-01 AMP-SC
DDS-092-AMPSC 3 of 3
RESET (Reset) Pushbutton switchWhen the pushbutton is pressed, reset is executed in the card and the card is initialized. Reset holding time is about 10 sec.
Table 1 LED indicators and operation block (2/2)
State Display/Operation
Description
A50016-G5000-G225-1-7631DDS-092-ASI00-11 (E)-01 ASI
DDS-092-ASI00 1 of 3
ASI
1. CARD LAYOUT
This card is used to control the ATM bus and B-SHF UTOPIA bus. The card is also used to transmit base-band clock signals, mount the PS cards and fans on the B-SHF, and monitor the cards and fans to check for alarms.
Fig. 1 Front view of ASI
ACT LED (Green)ALM LED (Red)ERR LED (Red)
BLK LED (Red)BLK Button (Pushbutton switch)
Connector for Ethernet communication
RESET Button (Pushbutton switch)
Front View
Card Ejector
Card Ejector
RESET
ALMERR
BLK
ACT
Ether
A50016-G5000-G225-1-7631DDS-092-ASI00-11 (E)-01 ASI
DDS-092-ASI00 2 of 3
Table 1 LED indicators and operation block (1/2)
State Display/Operation
Description
ACT (Normal operation) LED (Green)
(Lighting condition)
- When being operated normally
- During pre-blocking, both of ACT and BLK are lit.
(Lighting out condition)
- When alarm occurs
- When normal standby
- When resetting
- When changed to blocked state
ALM (Alarm) LED (Red)
(Lighting condition)
- When internal hardware, firmware or software error occurs.
(Lighting out condition)
- When resetting
ERR (Error) LED (Red)
(Lighting condition)
- Error in receiving signal from ATM card
(Lighting out condition)
- When signal was normally received from ATM card
- When resetting
A50016-G5000-G225-1-7631DDS-092-ASI00-11 (E)-01 ASI
DDS-092-ASI00 3 of 3
BLK (Blocked)LED (Red)
(Lighting condition)
- In pre-blocking state or blocking state
(Blinking condition)
- During self-diagnosis
(Lighting out condition)
- When blocked state is released
- When resetting
Pushbutton switch Each time the pushbutton switch is pressed once, blocked state or unblocked state is alternatively repeated.
RESET (Reset) Pushbutton switchWhen pushbutton switch was pressed, reset is executed in a card and the card is initialized.Reset holding time is about 10 sec.
Table 1 LED indicators and operation block (2/2)
State Display/Operation
Description
A50016-G5000-G225-1-7631DDS-092-ATM00-11 (E)-01 ATM
DDS-092-ATM00 1 of 3
ATM
1. CARD LAYOUT
This card is used to control the ATM bus and B-SHF buses that transfer user data and control data. The card is also used to relay BB (base-band) clock signals and bus monitor signals, and monitor each bus.
Fig. 1 Front view of ATM
Front View
ACT LED (Green)ALM LED (Red)ERR LED (Red)
BLK LED (Red)BLK Button (Pushbutton switch)
Connector for Ethernet communication
RESET Button (Pushbutton switch)
Card Ejector
Card Ejector
ATM
ALMACT
BLK
Ether
RESET
ERR
A50016-G5000-G225-1-7631DDS-092-ATM00-11 (E)-01 ATM
DDS-092-ATM00 2 of 3
Table 1 LED indication and operation block (1/2)
State Display/Operation Description
ACT (Normal operation) LED (Green)
(Lighting condition)
- When being operated normally
- During pre-blocking, both of ACT and BLK are lit.
(Lighting out condition)
- When alarm occurs
- When normal standby
- When resetting
- When changed to blocked state
ALM (Alarm) LED (Red)
(Lighting condition)
- When internal hardware and firmware errors occur
(Lighting out condition)
- When resetting
ERR (Error) LED (Red)
(Lighting condition)
- Signal receiving error from ASI card
(Lighting out condition)
- When Signal is normally received from ASI card
- When resetting
BLK (Blocked)LED (Red)
(Lighting condition)
- In pre-blocking state or blocking state
(Blinking condition)
- During self-diagnosis
(Lighting out condition)
- When blocked state is released
- When resetting
Pushbutton switch Each time the pushbutton switch is pressed once, blocked state or unblocked state is alternatively repeated.
A50016-G5000-G225-1-7631DDS-092-ATM00-11 (E)-01 ATM
DDS-092-ATM00 3 of 3
RESET (Reset) Pushbutton switchWhen pushbutton switch is pressed, reset is executed in a card and the card is initialized. Reset holding time is about 10 sec.
Table 1 LED indication and operation block (2/2)
State Display/Operation Description
A50016-G5000-G225-1-7631DDS-092-CHC00-11 (E)-01 CHC
DDS-092-CHC00 1 of 3
CHC
1. CARD LAYOUT
This card is used to process user data or control data received via the ATM bus or any of the B-SHF buses.
Fig. 1 Front view of CHC
Front View
ACT LED (Green)ALM LED (Red)ERR LED (Red)USE LED (Green)BLK LED (Red)BLK Button (Pushbutton switch)CH-C LED (Green)CH-T LED (Green)
Connector for Ethernet communication
Connector for Monitor
RESET Button (Pushbutton switch)
Card Ejector
Card Ejector
ETHER
ACT
CH-TCH-C
BLKUSE
ALMERR
RESET
MON
A50016-G5000-G225-1-7631DDS-092-CHC00-11 (E)-01 CHC
DDS-092-CHC00 2 of 3
Table 1 LED indicators and operation block (1/2)
State Display/Operation
Description
ACT (Normal operation) LED (Green)
(Lighting condition)
- When being operated normally
(Lighting out condition)
- When alarm occurs
- When resetting
ALM (Alarm) LED (Red)
(Lighting condition)
- When internal hardware and firmware errors occur
(Lighting out condition)
- When resetting
- When being operated normally
ERR (Error) LED (Red)
(Lighting condition)
- Lit when external clock or ATM clock disconnect is detected.
- When ATM short cell header CRC check error is detected.
- Lit when parity check error is detected in either of REP or Paired-CH selected.
(Lighting out condition)
- When error conditions above were eliminated.
USE (Circuit state) LED (Green)
(Lighting condition)
- When RL-ID is assigned
(Lighting out condition)
- The card is not mounted
A50016-G5000-G225-1-7631DDS-092-CHC00-11 (E)-01 CHC
DDS-092-CHC00 3 of 3
BLK (Blocked)LED (Red)
(Lighting condition)
- In pre-blocked state or blocked state
(Blinking condition)
- During self-diagnosis
(Lighting out condition)
- When blocked state is released.
- When resetting
Pushbutton switch Each time the pushbutton switch is pressed once, blocked state or unblocked state is alternatively repeated.
CH-C (State where control
channel is used)LED (Green)
(Lighting condition)
- When this card is used as a control channel card
(Lighting out condition)
- When this channel is used as a speech channel card
- When resetting
CH-T (State where speech
channel is used)LED (Green)
(Lighting condition)
- When this card is used as a speech channel card
(Lighting out condition)
- When this channel is used as a control channel card
- When resetting
RESET (Reset) Pushbutton switchWhen the pushbutton is pressed, reset is executed in the card and the card is initialized. Reset holding time is about 10 sec.
Table 1 LED indicators and operation block (2/2)
State Display/Operation
Description
A50016-G5000-G225-1-7631DDS-092-CLK00-11 (E)-01 CLK
DDS-092-CLK00 1 of 3
CLK
1. CARD LAYOUT
This card is used to generate clock signals required for each of the cards, and then supply the signals to the cards.
Fig. 1 Front view of CLK
Front View
ACT LED (Green)
Card Ejector
Card Ejector
RESET
ALMERR
ACT
BLK
CLK ON
10M
ETHER
WARM UP
FUNC
ON
BLK LED (Red)
CLK ON LED (Orange)
4-pole Switch
ERR LED (Red)ALM LED (Red)
Warm UP LED (Red)BLK Button (Pushbutton switch)
CLK ON Button (Pushbutton switch)
RESET Button (Pushbutton switch)
BNC Connector
Connector for Ethernet communication
A50016-G5000-G225-1-7631DDS-092-CLK00-11 (E)-01 CLK
DDS-092-CLK00 2 of 3
CAUTIONThe MONCLK terminal (BNC connector terminal) in the front of the CLK card outputs 10MHz TTL level clock. When connecting a measuring equipment such as Signal Generator (SG) to the terminal, adjust the input level of the measuring equipment to the output level of the terminal. Otherwise, the operation of the measuring equipment is not guaranteed.
Table 1 LED indicators and operation block (1/2)
State Display/Operation Description
ACT (Normal operation) LED (Green)
(Lighting condition)
- When being operated normally
- During pre-blocking, both of ACT and BLK are lit.
(Lighting out condition)
- When alarm occurs
- When changed to blocked state
ALM (Alarm) LED (Red)
(Lighting condition)
- When oscillation stop, reduction in output level were detected.
- When internal hardware and firmware software errors occur.
(Lighting out condition)
- When no internal hardware circuit failure and software error were detected.
- When resetting
ERR (Self-running mode) LED (Red)
(Lighting condition)
- Lit in self-running mode.
(Lighting out condition)
- Lit out in transmission path synch. mode.
A50016-G5000-G225-1-7631DDS-092-CLK00-11 (E)-01 CLK
DDS-092-CLK00 3 of 3
WARM UP (Warm up) LED (Red)
(Lighting condition)
- When turning power ON and inserting card to start warm up during warm up period of time.
(Lighting out condition)
- After termination of warm up period of time, the light is turned off. When instantaneous stop of power is for a few seconds or so, no warm up timer is reset.
CLK ON (Clock on)
LED (Orange)
(Lighting condition)
- When changed to CLK ON state
(Lighting out condition)
- When CLK ON state was released. After termination of warm up period of time, the light is turned off.
Pushbutton switch Each time the pushbutton switch is pressed once, CLK ON state or CLK OFF state is alternatively repeated.
BLK (Blocked)LED (Red)
(Lighting condition)
- When blocked
(Blinking)
- During self-diagnosis
(Lighting out condition)
- When blocked state is released
- When resetting
Pushbutton switch Each time the pushbutton switch is pressed once, blocked status or unblocked status is alternatively repeated.
RESET (Reset) Pushbutton switchWhen the pushbutton is pressed, reset is executed in the card and the card is initialized. Reset holding time is about 10 sec.
Table 1 LED indicators and operation block (2/2)
State Display/Operation Description
A50016-G5000-G225-1-7631DDS-092-CP000-11 (E)-01 CP
DDS-092-CP000 1 of 3
CP
1. CARD LAYOUT
This card is used to communicate with the IPL (initial program load) function and MT (maintenance tool).
Fig. 1 Front view of CP
Front View
ACT LED (Green)ALM LED (Red)
BLK LED (Red)BLK Button (Pushbutton switch)
Connector for SIO communication
Connector for Ethernet communication
RESET Button (Pushbutton switch)RESET
ETHER
ALMACT
BLK
MT
Card Ejector
Card Ejector
A50016-G5000-G225-1-7631DDS-092-CP000-11 (E)-01 CP
DDS-092-CP000 2 of 3
Table 1 LED indicators and operation block
State Display/Operation Description
ACT (Normal operation) LED (Green)
(Lighting condition)
- When IPL function normally terminates and operation is available
- During pre-blocking, both of ACT and BLK LED are lit.
(Lighting out condition)
- When alarm occurs
- When normal standby
- When resetting
- When changed to blocked state
ALM (Alarm) LED (Red)
(Lighting condition)
- IPL failure
- Internal hardware error
- Software error of call processing AP (CP-AP) and maintenance supervision control AP (SV-AP)
(Lighting out condition)
- When reset starts
BLK (Blocked)LED (Red)
(Lighting condition)
- In pre-blocking state or blocking state
(Blinking condition)
- During self-diagnosis
(Lighting out condition)
- When blocking state is released
- When being reset
Pushbutton switch Each time the pushbutton switch is pressed once, blocked status or unblocked status is alternatively repeated.
A50016-G5000-G225-1-7631DDS-092-CP000-11 (E)-01 CP
DDS-092-CP000 3 of 3
RESET (Reset) Pushbutton switchWhen the pushbutton is pressed, reset is executed in the card and the card is initialized. Reset holding time is about 10 sec.
Table 1 LED indicators and operation block
State Display/Operation Description
A50016-G5000-G225-1-7631DDS-092-DUAMC-11 (E)-01 DUAMCO
DDS-092-DUAMC 1 of 4
DUAMCO
1. CARD LAYOUT
This card has the function of both RX Low-noise Amplifier (RX AMP) and Tower Top Amplifier Monitor (TTA-M).
Fig. 1 Front view of DUAMCO
Front View
ACT LED (Green) TTA BYP LED (Green)ANT 0 Connector TTA LNA LED (Red)ANT 1 Connector TTA PS LED (Red)FREQ Switch TX MON 0 ConnectorMODE Switch TX MON 1 ConnectorRESET Button (Pushbutton Switch) VSWR LED (Red)RX AMP LED (Red)
PS
OFF
ON
I
O
RESET
ANT 0 ANT 1TX MON 0 TX MON 1
ON/OFF Switch
Volume Switch(1db step)
Screw
0 10TTA ATT
VSWRRX
AMPTTALNA
TTAPS ACT
TTABYP
DUAMCO 0
ALM MODETTA
+RXAMP
RXAMP
FREQ
HL
0 10TTA ATT
VSWRRX
AMPTTALNA
TTAPS ACT
TTABYP
DUAMCO 1
ALM
A50016-G5000-G225-1-7631DDS-092-DUAMC-11 (E)-01 DUAMCO
DDS-092-DUAMC 2 of 4
Table 1 LED indicators and operation block (1/3)
State Display/Operation Description
ACT (Normal operation) LED (Green)
(Lighting condition)
- When receiving system 0 (or 1) is in normal operation and ALM has not occurred
(Lighting out condition)
- When ALM occurred in receiving system 0 (or 1)
- When the power is OFF
TTA BYP (Mode) LED (Red)
(Lighting condition)
- When the TTA bypass mode is chosen (with deciding that TTA is impossible to operate)* Keep [RX 0 (and 1) RXAMP/TTA MODE] to AMP-SC in TTA MODE.
(Lighting out condition)
- When the RXAMP mode is chosen
- When the TTA operation is O.K. in the TTA mode(Since only degradation of TTA is required when only one side of the parallel configuration is abnormal, it is not set to the TTA bypass mode.)
- When the power is OFF
TTA LNA (Alarm) LED (Red)
(Lighting condition)
- When LNA in system 0 (or 1) in TTA is abnormal(This is "TTA 0 (or 1) LNA ALM" even when only one side of the parallel configuration is abnormal)* The protection operation does not work.* The display is maintained by itself.* Sends out to AMP-SC as [RX 0 (or 1) ALM]
(Lighting out condition)
- When the power is OFF
- When resetting
A50016-G5000-G225-1-7631DDS-092-DUAMC-11 (E)-01 DUAMCO
DDS-092-DUAMC 3 of 4
TTA PS (Alarm) LED (Red)
(Lighting condition)
- When the supply voltage to LNA in system 0 (or 1) in TTA fell down and stopped
- When the cables between DUAMCO - TTA are abnormal* The protection operation interrupts PS output in the case of only the abnormalities originating in an over-current.* The display is maintained by itself * Sends out to AMP-SC as [RX 0 (or 1) ALM].
(Lighting out condition)
- When the power is OFF
- When resetting
RXAMP (Alarm) LED (Red)
(Lighting condition)
- When RXAMP in system 0 (or 1) in DUAMCO is abnormal * The protection operation does not work.* The display is maintained by itself.* Sends out to AMP-SC as [RX 0 (and 1) ALM].
(Lighting out condition)
- When the power is OFF
- When resetting
VSWR (Alarm) LED (Red)
(Lighting condition)
- When VSWR is abnormal (VSWR > 3) at antenna interface end in system 0 (or 1) in DUAMCO* The protection operation does not work.* The display is maintained by itself.* Sends out to AMP-SC as [DUAMCO 0 (or 1) VSWR ALM].
(Lighting out condition)
- When the power is OFF
- When ALM returns
Table 1 LED indicators and operation block (2/3)
State Display/Operation Description
A50016-G5000-G225-1-7631DDS-092-DUAMC-11 (E)-01 DUAMCO
DDS-092-DUAMC 4 of 4
RXAMP /TTA+RXAMP
(Mode)Switch
Choose the RXAMP mode that does not use TTA, and the TTA+RXAMP mode that uses TTA. * The switch with a lock is used.
TTA ATT (Mode) Rotary switch
Since the cable loss between TTA and DUAMCO is compensated at the time of the TTA mode, the amount of attenuation can be varied at a maximum of 10dB by 1dB step.* In the RXAMP mode or TTA bypass mode, even if it turns a switch, the amount of attenuation is fixed.* The amount of attenuation can be checked visually.
FREQ SwitchSet up the frequency band of the bank filter in DUAMCO. * The switch with a lock is used.
PS ON/OFF (Power)
- Turns ON/OFF of the power supplied to DUAMCO.
- Interrupt the power at the time of an over-current.* Having a structure that cannot easily be pressed down.* The operation part is not projected from the surroundings of it.* The NFB itself is displayed as "0" at the ON side and " 01" at the OFF side.
RESET (Reset) Pushbutton switchInitialize DUAMCO.* Non-lock type switch is used.* Having a structure that cannot easily be pressed down.
TX MON 0 / TX MON 1 (Monitor) SMA-J connector
Transmission side monitor terminal in system 0 (or 1) in DUAMCO (the amount of combination is 40dB)* The cap with a chain is attached.* The amount of combination measured at 2140MHz is displayed near this monitor terminal.
Table 1 LED indicators and operation block (3/3)
State Display/Operation Description
A50016-G5000-G225-1-7631DDS-092-EIU00-11 (E)-01 EIU
DDS-092-EIU00 1 of 4
EIU
1. CARD LAYOUT
This card is used to store, in the PC memory card, the log files and traffic data concerning the function for monitoring bus signals in the rack, the function for transferring files to the SDM/GM, and the maintenance and control of the Node B.
Fig. 1 Front view of EIU
START/STOP
SYSRST
ETHER
ALMERR
ACT
MT
BLK
SENDREC
OKNG
RESET
Front View
USE
FUNC
ON
ACT LED (Green)ALM LED (Red)ERR LED (Red)
USE LED (Green)SEND LED (Green)REC LED(Green)BLK LED (Red)BLK Button(Pushbutton switch)OK LED (Green)NG LED (Red)START/STOP Button (Pushbutton switch)8-pole Switch
Connector for SIO communication
Connector for Ethernet communication
SYSRST Button (Pushbutton switch) (cover for preventing improper operation is attached.)RESET Button(Pushbutton switch)
PC Card Slot (PCMCIA TYPE II ATA card 96MB for FLD)Card Ejector
Card Ejector
A50016-G5000-G225-1-7631DDS-092-EIU00-11 (E)-01 EIU
DDS-092-EIU00 2 of 4
Table 1 LED indicators and operation block (1/3)
State Display/Operation Description
ACT (Normal operation) LED (Green)
(Lighting condition)
- When being operated normally
(Lighting out condition)
- When alarm occurs
- When resetting
- When changed to blocked state
ALM (Alarm) LED (Red)
(Lighting condition)
- When internal hardware and firmware errors occur
(Lighting out condition)
- When resetting
ERR (Error) LED (Red)
(Lighting condition)
- Lit for 200ms when parity error of received message occurs.
- When line disconnection of AMP-SC-INTF, TTA-INTF was detected.
(Lighting out condition)
- When error conditions above were eliminated.
USE (Mounting PC card for FLD) LED (Green)
(Lighting condition)
- Mounting PC card for FLD
(Lighting out condition)
- PC card for FLD not mounted
SEND (Data transmission) LED (Green)
(Lighting condition)
- When message was transmitted to AMP-SC, TTA, lit for about 200ms.
(Lighting out condition)
- When no data is transmitted
A50016-G5000-G225-1-7631DDS-092-EIU00-11 (E)-01 EIU
DDS-092-EIU00 3 of 4
REC (Data receive) LED (Green)
(Lighting condition)
- When normal message was received from AMP-SC, TTA, in for about 200ms.
(Lighting out condition)
- When no data is released.
BLK (Blocked)LED (Red)
(Lighting condition)
- In pre-blocking state or blocking state
(Blinking condition)
- During self-diagnosis
(Lighting out condition)
- When blocking state is released
- When resetting
Pushbutton switch Each time the pushbutton switch is pressed once, blocked status or unblocked status is alternatively repeated.
OK (File transferring state) LED (Green)
(Blinking condition)
- During transferring file, blinks in a cycle of 200msec
(Lighting out condition)
- PC card for FLD not mounted
NG (File transferring state) LED (Red)
(Lighting condition)
Lit when the following factors occur.
- When operated when PC card for FLD was not mounted.
- When error occurs in the processing related to PC card for FLD.
(Lighting out condition)
- When error factors were eliminated and START/STOP Pushbutton switch was pressed.
Table 1 LED indicators and operation block (2/3)
State Display/Operation Description
A50016-G5000-G225-1-7631DDS-092-EIU00-11 (E)-01 EIU
DDS-092-EIU00 4 of 4
START/STOP (Operation start/
forced stop)Pushbutton switch
- Operates processing set with FUNC switch.
- Executes ScanDisk.
- Implements dismount processing of PC card.
- Starts transferring file.
- When this was pressed during file transfer, file transfer is forcibly terminated. When it is pressed in other cases, it is ignored.
- Turns off NG LED in NG holding state.
RESET (Reset) Pushbutton switchWhen the pushbutton is pressed, reset is executed in the card and the card is initialized. Reset holding time is about 10 sec.
SYSRST (System Reset) Pushbutton switch Executes reset for entire unit and initializes entire unit.
Cover for preventing improper operation is attached.
Table 1 LED indicators and operation block (3/3)
State Display/Operation Description
A50016-G5000-G225-1-7631DDS-092-FAN00-11 (E)-01 FAN
DDS-092-FAN00 1 of 1
FAN
1. CARD LAYOUT
This card is used to cool the B/T-SHF cards.
Fig. 1 Front view of FAN
Table 1 LED indicators and operation block
State Display/Operation
Description
ALM (Alarm) LED (Red)
(Lighting condition)
- When error occurs in FAN unit
(Lighting out condition)
- When being operated normally
ALM LED (Red)
Front View
-48VALM
3A
Screw Screw
A50016-G5000-G225-1-7631DDS-092-HWM20-11 (E)-01 HWY-MON20
DDS-092-HWM20 1 of 2
HWY-MON20
1. CARD LAYOUT
This card is used to monitor the 2M transfer circuit.
Fig. 1 Front view of HWY-MON20
Front View
Screw
Screw
E1
BA
LAN
CE
E1 BALANCEor E1 UNBALANCE
EXT CLK
EX
T-C
LK
A50016-G5000-G225-1-7631DDS-092-HWM20-11 (E)-01 HWY-MON20
DDS-092-HWM20 2 of 2
Table 1 LED indicators and operation block
State Display/Operation
Description
E1 BALANCE /E1 UNBALANCE Monitor
Monitor terminal for highway signal monitor. The state (E1 BALANCE / E1 UNBALANCE) is changed by reversing the SUB board mounted on the main board.
EXT-CLK ConnectorConnector for the MS simulator and others. This connector outputs clock signals (8KHz clock signal/BFN reset signal).
A50016-G5000-G225-1-7631DDS-092-MCPA0-11 (E)-01 MCPA
DDS-092-MCPA0 1 of 4
MCPA
1. CARD LAYOUT
This card is used to amplify RF signals transmitted from the TRX card.
Fig. 1 Front view of MCPA
Front View
Screw
MCPA
MONACTALMBLKWARM UP
RESET
BLK
PSON
OFF
RF Monitor
Screw
ON/OFF Switch
ACT LED (Green)ALM LED (Red)BLK LED (Red)WARMUP LED (Orange)
RESET Button (Pushbutton switch)
BLK Button (Pushbutton switch)
BAND SET (Cover is attached.)
A50016-G5000-G225-1-7631DDS-092-MCPA0-11 (E)-01 MCPA
DDS-092-MCPA0 2 of 4
Table 1 LED indicators and operation block (1/3)
State Display/Operation
Description
ACT (Normal operation) LED (Green)
(Lighting condition)
- When MCPA operates normally and ALM does not occur
(Lighting out condition)
- When MCPA cannot operate normally and ALM occurs
- When MCPA does not start normally
- When MCPA is not given power supply or it is suspended.
- When the reset control is carried out
- When the BLK control is carried out
ALM (Alarm) LED (Red)
(Lighting condition)
- When gains exceed the rated value
- When inter-modulation degrades
- When excessive output is made
- When internal temperature is higher than a temperature for guaranteed operation
- When error occurs in distortion compensator
- When abnormalities occur in internal power supply
- When abnormalities occur in the CPU circuit
(Lighting out condition)
- When the power is OFF
- When resetting
A50016-G5000-G225-1-7631DDS-092-MCPA0-11 (E)-01 MCPA
DDS-092-MCPA0 3 of 4
BLK (Blocked)LED (Red)
(Lighting condition)
- When the front switch is turned on or the BLK command (late call priority) is issued (transmission output is suspended).
(Lighting out condition)
- When the front switch is turned off or the BLK release command is issued with remote control.
- When reset control is carried out. (the operation state is returned after started, when the reset control is carried out)
Pushbutton switch Each time the pushbutton switch is pressed once, blocked status or unblocked status is alternatively repeated.
WARM UP (Preparation) LED (Red)
(Lighting condition)
- When the heat balance is not maintained right after the power supply is started.
- Until the distortion compensation control circuit is completed under initialization after reset. Carrier output is allowed even in the warm-up process.
(Lighting out condition)
- When no ON condition exists.
- When resetting
- When the power is OFF
RESET (Reset) Pushbutton switchWhen the pushbutton is pressed, reset is executed in the card and the card is initialized. Reset holding time is about 10 sec.
PS ON/OFF (Power)
This switch allows the power to be supplied to a card and not to supplied to the card, and it can stop the power supply in the case of over-current.
Table 1 LED indicators and operation block (2/3)
State Display/Operation
Description
A50016-G5000-G225-1-7631DDS-092-MCPA0-11 (E)-01 MCPA
DDS-092-MCPA0 4 of 4
BAND SET (Frequency Setup) Rotary switch
According to bandwidth used for the optimization of electrical property, rotary switches are set in the following:0 : No Setting (No setting is allowed) 1 :2110 to 2130MHz 2 :2120 to 2140MHz 3 :2130 to 2150MHz 4 :2140 to 2160MHz 5 :2150 to 2170MHz 6, 7, 8,9: No Setting (No setting is allowed)* After a change in the setting of rotary switches, the unit reset or the power supply needs to be done.
MON (Monitor) The monitor terminal of RF output. This monitor outputs about -40dBm in the case of the rated output.
Table 1 LED indicators and operation block (3/3)
State Display/Operation
Description
A50016-G5000-G225-1-7631DDS-092-PS100-11 (E)-01 PS1
DDS-092-PS100 1 of 2
PS1
1. CARD LAYOUT
This card is used to supply the rated power input required for the B-SHF common shelf to operate.
Fig. 1 Front view of PS1
ACT
ON
OFF
Front View
ACT LED (Green)
ON/OFF Switch
Card Ejector
Card Ejector
A50016-G5000-G225-1-7631DDS-092-PS100-11 (E)-01 PS1
DDS-092-PS100 2 of 2
Table 1 LED indicators and operation block
State Display/Operation
Description
ACT (Normal operation) LED (Green)
(Lighting condition)
- When supplying power
(Lighting out condition)
- When power supply stops
- When resource error occurs
A50016-G5000-G225-1-7631DDS-092-PS200-11 (E)-01 PS2
DDS-092-PS200 1 of 2
PS2
1. CARD LAYOUT
This card is used to supply the rated power input required for the B-SHF channel shelf to operate.
Fig. 1 Front view of PS2
ACT
ON
OFF
Front View
ACT LED (Green)
ON/OFF Switch
Card Ejector
Card Ejector
A50016-G5000-G225-1-7631DDS-092-PS200-11 (E)-01 PS2
DDS-092-PS200 2 of 2
Table 1 LED indicator and operation block
State Display/Operation
Description
ACT (Normal operation) LED (Green)
(Lighting condition)
- When supplying power
(Lighting out condition)
- When power supply stops
- When resource error occurs
A50016-G5000-G225-1-7631DDS-092-REP00-11 (E)-01 REP
DDS-092-REP00 1 of 3
REP
1. CARD LAYOUT
This card is mounted between the CHC and TRX cards to perform inter-shelf communication.
Fig. 1 Front view of REP
Front View
RESET
ACTALMERRUSEBLK
ETHER
R-R1R-R0
ACT LED (Green)ALM LED (Red)ERR LED (Red)USE LED (Green)BLK LED (Red)BLK Button (Pushbutton switch)
Connector for communication between REP-REP
Connector for communication between REP-REP
Connector for Ethernet communication
RESET Button (Pushbutton switch)
Card Ejector
Card Ejector
A50016-G5000-G225-1-7631DDS-092-REP00-11 (E)-01 REP
DDS-092-REP00 2 of 3
Table 1 LED indicators and operation block (1/2)
State Display/Operation
Description
ACT (Normal operation) LED (Green)
(Lighting condition)
- When being operated normally
(Lighting out condition)
- When resetting
ALM (Alarm) LED (Red)
(Lighting condition)
- Lit when internal hardware and firmware errors occur.
(Lighting out condition)
- When being operated normally.
- When resetting
ERR (Error) LED (Red)
(Lighting condition)
- Lit when external clock or signal received from ATM card is abnormal.
- When unlocked deserializer is detected
- When parity check error is detected
(Lighting out condition)
- When error conditions above were eliminated.
USE (Circuit state) LED (Green)
(Lighting condition)
- When REP card is mounted
(Lighting out condition)
- REP card is not mounted
A50016-G5000-G225-1-7631DDS-092-REP00-11 (E)-01 REP
DDS-092-REP00 3 of 3
BLK (Blocked)LED (Red)
(Lighting condition)
- In pre-blocked state or blocked state
(Blinking condition)
- During self-diagnosis
(Lighting out condition)
- When blocked state is released.
- When resetting
Pushbutton switch Each time the pushbutton switch is pressed once, blocked state or unblocked state is alternatively repeated.
RESET (Reset) Pushbutton switch Pressing the pushbutton switch resets and initializes the card. The reset holding time is about 10 seconds.
Table 1 LED indicators and operation block (2/2)
State Display/Operation
Description
A50016-G5000-G225-1-7631DDS-092-RFSW0-11 (E)-01 RFSW
DDS-092-RFSW0 1 of 3
RFSW
1. CARD LAYOUT
This card is used to distribute and integrate input and output RF signals.
Fig. 1 Front view of RFSW
Front View
TRX 0 LED (Green)TRX 1 LED (Green)TRX 2 LED (Green)TRX 3 LED (Green)TRX 4 LED (Green)TRX 5 LED (Green)TRX E LED (Green)
TRX 0TRX 1TRX 2
TRX 5
TRX 3TRX 4
TRX E
Screw
Card Ejector
A50016-G5000-G225-1-7631DDS-092-RFSW0-11 (E)-01 RFSW
DDS-092-RFSW0 2 of 3
Table 1 LED indicators and operation block (1/2)
State Display/Operation
Description
TRX 0 LED (Green)
(Lighting condition)
- When being operated normally in the TRX 0 system
(Lighting out condition)
- When being switched to standby TRX
TRX 1 LED (Green)
(Lighting condition)
- When being operated normally in the TRX 1 system
(Lighting out condition)
- When being switched to standby TRX
TRX 2 LED (Green)
(Lighting condition)
- When being operated normally in the TRX 2 system
(Lighting out condition)
- When being switched to standby TRX
TRX 3 LED (Green)
(Lighting condition)
- When being operated normally in the TRX 3 system
(Lighting out condition)
- When being switched to standby TRX
TRX 4 LED (Green)
(Lighting condition)
- When being operated normally in the TRX 4 system
(Lighting out condition)
- When being switched to standby TRX
TRX 5 LED (Green)
(Lighting condition)
- When being operated normally in the TRX 5 system
(Lighting out condition)
- When being switched to standby TRX
A50016-G5000-G225-1-7631DDS-092-RFSW0-11 (E)-01 RFSW
DDS-092-RFSW0 3 of 3
TRX E LED (Green)
(Lighting condition)
- When being switched to standby TRX
(Lighting out condition)
- When being operated normally in all TRX 0-5 systems.
Table 1 LED indicators and operation block (2/2)
State Display/Operation
Description
A50016-G5000-G225-1-7631DDS-092-SCPA0-11 (E)-01 SCPA
DDS-092-SCPA0 1 of 4
SCPA
1. CARD LAYOUT
This card is used to amplify RF signals transmitted from the TRX card.
Fig. 1 Front view of SPCA
Front View
Screw
RF Monitor
ACT LED (Green)ALM LED (Red)BLK LED (Red)WARMUP LED (Orange)
RESET Button (Pushbutton switch)
BLK Button (Pushbutton switch)
BAND SET (Cover is attached.)
ON/OFF Switch
Screw
PSON
OFF
SCPA
ACTALMBLKWARM UP
RESET
BLK
MON
A50016-G5000-G225-1-7631DDS-092-SCPA0-11 (E)-01 SCPA
DDS-092-SCPA0 2 of 4
Table 1 LED indicators and operation block (1/3)
State Display/Operation
Description
ACT (Normal operation) LED (Green)
(Lighting condition)
- When SCPA operates normally and ALM does not occur
(Lighting out condition)
- When SCPA cannot operate normally and ALM occurs
- When SCPA does not start normally
- When SCPA is not given power supply or it is suspended.
- When the reset control is carried out
- When the BLK control is carried out
ALM (Alarm) LED (Red)
(Lighting condition)
- When gains exceed the rated value
- When inter-modulation degrades
- When excessive output is made
- When internal temperature is higher than a temperature for guaranteed operation
- When error occurs in distortion compensator
- When abnormalities occur in internal power supply
- When abnormalities occur in the CPU circuit
(Lighting out condition)
- When the power is OFF
- When resetting
A50016-G5000-G225-1-7631DDS-092-SCPA0-11 (E)-01 SCPA
DDS-092-SCPA0 3 of 4
BLK (Blocked)LED (Red)
(Lighting condition)
- When the front switch is turned on or the BLK command (late call priority) is issued (transmission output is suspended).
(Lighting out condition)
- When the front switch is turned off or the BLK release command is issued with remote control.
- When reset control is carried out. (the operation state is returned after started, when the reset control is carried out)
Pushbutton switch Each time the pushbutton switch is pressed once, blocked status or unblocked status is alternatively repeated.
WARM UP (Preparation) LED (Red)
(Lighting condition)
- When the heat balance is not maintained right after the power supply is started.
- Until the distortion compensation control circuit is completed under initialization after reset. Carrier output is allowed even in the warm-up process.
(It is not necessary to satisfy electric performance. However, the undesirable states of AMP equipment, such as breakage of AMP equipment, excessive output, unusual oscillation, do not occur.)
(Lighting out condition)
- When no ON condition exists.
- When resetting
- When the power is OFF
RESET (Reset) Pushbutton switchWhen the pushbutton is pressed, reset is executed in the card and the card is initialized. Reset holding time is about 10 sec.
PS ON/OFF (Power)
This switch allows the power to be supplied to a card and not to supplied to the card, and it can stop the power supply in the case of over-current.
Table 1 LED indicators and operation block (2/3)
State Display/Operation
Description
A50016-G5000-G225-1-7631DDS-092-SCPA0-11 (E)-01 SCPA
DDS-092-SCPA0 4 of 4
BAND SET (Frequency Setup) Rotary switch
According to bandwidth used for the optimization of electrical property, rotary switches are set in the following:0 : No Setting (No setting is allowed) 1 :2110 to 2130MHz 2 :2120 to 2140MHz 3 :2130 to 2150MHz 4 :2140 to 2160MHz 5 :2150 to 2170MHz 6, 7, 8: No Setting (No setting is allowed)9 : For Inspection (No setting is allowed) * After a change in the setting of rotary switches, the unit reset or the power supply needs to be done.
MON (Monitor) The monitor terminal of RF output. This monitor outputs about -10dBm in the case of the rated output.
Table 1 LED indicators and operation block (3/3)
State Display/Operation
Description
A50016-G5000-G225-1-7631DDS-092-SDM00-11 (E)-01 SDM
DDS-092-SDM00 1 of 3
SDM
1. CARD LAYOUT
This card includes nonvolatile memory to store the program files, data files for Node B operation, and firmware for the other cards.
Fig. 1 Front view of SDM
RESET
ETHER
ALM
NOT RDY
ACT
BLK
WE
Front View
ACT LED (Green)ALM LED (Red)
NOT RDY LED (Orange)
BLK LED (Red)BLK Button (Pushbutton switch)WE LED (Orange)WE Button (Pushbutton switch)
Connector for Ethernet communication
RESET Button (Pushbutton switch)
Card Ejector
Card Ejector
A50016-G5000-G225-1-7631DDS-092-SDM00-11 (E)-01 SDM
DDS-092-SDM00 2 of 3
Table 1 LED indicators and operation block (1/2)
State Display/Operation Description
ACT (Normal operation) LED (Green)
(Lighting condition)
- When being operated normally
- During pre-blocking, both of ACT and BLK LED are lit.
(Lighting out condition)
- When alarm occurs
- When normal standby
- When resetting
- When changed to blocked state
ALM (Alarm) LED (Red)
(Lighting condition)
- When internal hardware and firmware software errors and memory failure occur
(Lighting out condition)
- When resetting
WE (Write enable)
LED (Orange)
(Lighting condition)
- Lit in write enable state.
(Blinking condition)
- Writing
(Lighting out condition)
- Write complete
- Lit out in write protection state.
- When resetting
Pushbutton switchEvery time pushbutton switch is pressed, write enable (writable state) and write protect (write protection state) to SDM unit are repeated.
A50016-G5000-G225-1-7631DDS-092-SDM00-11 (E)-01 SDM
DDS-092-SDM00 3 of 3
NOTRDY (Not ready) LED (Orange)
(Lighting condition)
- Transferring memory to make the memory of GM unit of STBY card equal to the memory of ACT card.
(Lighting out condition)
- Transfer complete in GM unit
- When resetting
BLK (Blocked)LED (Red)
(Lighting condition)
- When blocked
(Blinking condition)
- During self-diagnosis
(Lighting out condition)
- When blocking state is released
- When resetting
Pushbutton switch Each time the pushbutton switch is pressed once, blocked state or unblocked state is alternatively repeated.
RESET (Reset) Pushbutton switchWhen the pushbutton is pressed, reset is executed in the card and the card is initialized. Reset holding time is about 10 sec.
Table 1 LED indicators and operation block (2/2)
State Display/Operation Description
A50016-G5000-G225-1-7631DDS-092-TRX00-11 (E)-01 TRX
DDS-092-TRX00 1 of 3
TRX
1. CARD LAYOUT
This card is used to transmit and receive RF signals.
Fig. 1 Front view of TRX
RESET
ETHER
ALMERRUSEBLK
ACT
Front View
ACT LED (Green)ALM LED (Red)ERR LED (Red)USE LED (Green)BLK LED (Red)BLK Button (Pushbutton switch)
Connector for Ethernet communication
RESET Button (Pushbutton switch)
Card Ejector
Card Ejector
A50016-G5000-G225-1-7631DDS-092-TRX00-11 (E)-01 TRX
DDS-092-TRX00 2 of 3
Table 1 LED indicators and operation block (1/2)
State Display/Operation
Description
ACT (Normal operation) LED (Green)
(Lighting condition)
- When being operated normally
- During pre-blocking, both of ACT and BLK are lit.
(Lighting out condition)
- When alarm occurs
- When resetting
ALM (Alarm) LED (Red)
(Lighting condition)
- Lit when synthesizer is unlocked.
- When transmission output level error is detected.
- When CPU alarm is detected.
- When internal hardware and firmware errors are detected.
(Lighting out condition)
- When being operated normally.
- When resetting
ERR (Error) LED (Red)
(Lighting condition)
- Lit when external clock or signal received from ATM card is abnormal.
- When unlocked deserializer is detected.
- When step-out by synchronous bit/word is detected.
- When parity check error is detected.
(Lighting out condition)
- When error conditions above were eliminated.
A50016-G5000-G225-1-7631DDS-092-TRX00-11 (E)-01 TRX
DDS-092-TRX00 3 of 3
USE (Transmission
output on)LED (Green)
(Lighting condition)
- When function setup in the active card is completed and resources are obtained
(Lighting out condition)
- When resources are released
BLK (Blocked)LED (Red)
(Lighting condition)
- In pre-blocked state or blocked state
(Blinking condition)
- During self-diagnosis
(Lighting out condition)
- When blocked state is released.
- When resetting
Pushbutton switch Each time the pushbutton switch is pressed once, blocked state or unblocked state is alternatively repeated.
RESET (Reset) Pushbutton switch Pressing the pushbutton switch resets and initializes the card. The reset holding time is about 10 seconds.
Table 1 LED indicators and operation block (2/2)
State Display/Operation
Description
A50016-G5000-G225-1-7631ND-57315-706 (E)-01
SECTION 5TTA
A50016-G5000-G225-1-7631DDS-092-TTA00-11 (E)-01 TTA
DDS-092-TTA00 1 of 2
TTA
1. TTA LAYOUT
Fig. 1 Front view and right side view of TTA
Front View
Right Side View
(27)198.58
(236
)
(232
)
φ
Unit: mm
A50016-G5000-G225-1-7631DDS-092-TTA00-11 (E)-01 TTA
DDS-092-TTA00 2 of 2
Fig. 2 Rear view and bottom view of TTA
Rear View
Bottom View
4 - M12Depth 30
180 1.2±
143
1.2
±
CAUTION
TX/RX1
ANT1
GND
TX/RX0
ANT0
Unit: mm
A50016-G5000-G225-1-7631ND-57315-706 (E)-01
SECTION 6INTERFACE PORT
A50016-G5000-G225-1-7631DDS-092-CNTIF-11 (E)-01 Control System Expansion Interface
DDS-092-CNTIF 1 of 1
Control System Expansion Interface
1. INTERFACE PORT LAYOUT
Fig. 1 Control System Expansion Interface layout
Front
Location of bay top
AS
IC
LK
A50016-G5000-G225-1-7631DDS-092-HWYIF-11 (E)-01 HWY Interface
DDS-092-HWYIF 1 of 1
HWY Interface
1. INTERFACE PORT LAYOUT
Fig. 1 HWY interface layout
Front
Location of bay top
IN 0 OUT 0 IN 1 OUT 1STM1 OPTICAL
HWY 0 HWY 2 HWY 4 HWY 1 HWY 3 HWY 5E1 BALANCE
IN 0 OUT 4OUT 0 IN 2 OUT 2 IN 4 IN 1 OUT 5OUT 1 IN 3 OUT 3 IN 5E1 UNBALANCE
A50016-G5000-G225-1-7631DDS-092-PWRIF-11 (E)-01 PWR Interface
DDS-092-PWRIF 1 of 1
PWR Interface
1. INTERFACE PORT LAYOUT
Fig. 1 PWR interface layout
-48V IN
-48V-IN1( - )
-48V-G2( + )
-48V-G1( + )
-48V-IN2( - )
FG
Front
Location of bay top
A50016-G5000-G225-1-7631DDS-092-RFIF0-11 (E)-01 RF Interface
DDS-092-RFIF0 1 of 1
RF Interface
1. INTERFACE PORT LAYOUT
Fig. 1 RF interface layout
Front
Location of bay top
TX/RX RX TX/RXTX/RX RX RX
Sector 1 Sector 2 Sector 3
A50016-G5000-G225-1-7631DDS-092-RFIF1-11 (E)-01 RF System Expansion Interface
DDS-092-RFIF1 1 of 1
RF System Expansion Interface
1. INTERFACE PORT LAYOUT
Fig. 1 RF system expansion interface layout
Front
TX3-IN0 TX3-IN1
RX3-OUT1RX3-OUT0RX2-OUT1RX2-OUT0RX1-OUT1RX1-OUT0
TX1-IN0 TX1-IN1 TX2-IN0 TX2-IN1
Location of bay top
A50016-G5000-G225-1-7631DDS-092-SSRIF-11 (E)-01 Site Supervisory and Remote Control Interface
DDS-092-SSRIF 1 of 1
Site Supervisory and Remote Control Interface
1. INTERFACE PORT LAYOUT
Fig. 1 Site supervisory and remote control interface layout
Front
Location of bay top
PO
RT
IN/O
UT
25
50Connector Type: AMP 172875-6Screw Type: No.4-40 UNC, Depth 5mm
SE
RIA
L
1
26