1/9 www.ni.com 1. 2. 3. 4. 5. 6. : Document Type Tutorial : Yes NI Supported : Jun 21, 2007 Publish Date Getting Started Guide: Connect NI LabVIEW to Yaskawa SIGMA II Servo Amplifiers Overview This document provides step-by-step instructions to setup and program a motion control application using National Instruments (NI) LabVIEW and Yaskawa Sigma II servo amplifier including choosing the right hardware, hardware and software setup and programming. Table of Contents Hardware and Software Requirements Hardware Setup NI PCI-7390 Configuration using NI Measurement and Automation Explorer Configure moves with NI Motion Assistant (Optional) Export to LabVIEW Appendix Hardware and Software Requirements Controller Hardware and Accessories (National Instruments – www.ni.com/motion): 779034-01 NI PCI-7390, 4-axis position command motion controller with isolation 779611-01 MCA-7790Y, motion interface connection board and cable for Yaskawa Servo Amplifiers 194604-02 50 Pin cable for connecting MCA-7790Y to Yaskawa Sigma II Servo Amplifier Servo Amplifier and Motors (Yaskawa – www.yaskawa.com): SGDH-##xxx SGDH Sigma II Torque, Speed, or Position controlled servo amplifier 53460-0611 Servo Amplifier Encoder Connector (Yaskawa Number: JZSP-CMP9-1,2) Motion Control Software (National Instruments - www.ni.com): 776678-09 LabVIEW Professional System for Windows 778553-01 NI Motion Assistant for motion controller programming (Optional) - NI-MOTION Driver (Included with NI PCI-7390 controller) Hardware Setup 1. Connect the NI PCI-7390 motion controller to the Yaskawa Sigma II amplifier: The NI MCA-7790Y accessory kit provides connection between the NI PCI-7390 controller and Sigma II series amplifiers from Yaskawa. To connect a Sigma II amplifier to the PCI-7390 controller, connect a 50-pin cable from the amplifier (PN: 194604-02) to the MCA-7790Y, and connect a SCSI 100-pin cable from the MCA-7790Y to the NI PCI-7390 (included with the MCA-7790Y). Refer to Figure 1 below.

NI Tutorial 5908

  • Upload
    dollare

  • View
    122

  • Download
    7

Embed Size (px)

Citation preview

Page 1: NI Tutorial 5908

1/9 www.ni.com

1. 2. 3. 4. 5. 6.

: Document Type Tutorial : Yes NI Supported: Jun 21, 2007 Publish Date

Getting Started Guide: Connect NI LabVIEW toYaskawa SIGMA II Servo AmplifiersOverview

This document provides step-by-step instructions to setup and program a motion control application using National Instruments (NI) LabVIEW and Yaskawa Sigma II servo amplifier includingchoosing the right hardware, hardware and software setup and programming.

Table of Contents

Hardware and Software RequirementsHardware SetupNI PCI-7390 Configuration using NI Measurement and Automation ExplorerConfigure moves with NI Motion Assistant (Optional)Export to LabVIEWAppendix

Hardware and Software Requirements

Controller Hardware and Accessories (National Instruments – www.ni.com/motion):

779034-01 NI PCI-7390, 4-axis position command motion controller with isolation

779611-01 MCA-7790Y, motion interface connection board and cable for Yaskawa Servo Amplifiers

194604-02 50 Pin cable for connecting MCA-7790Y to Yaskawa Sigma II Servo Amplifier

Servo Amplifier and Motors (Yaskawa – www.yaskawa.com):

SGDH-##xxx SGDH Sigma II Torque, Speed, or Position controlled servo amplifier

53460-0611 Servo Amplifier Encoder Connector (Yaskawa Number: JZSP-CMP9-1,2)

Motion Control Software (National Instruments - www.ni.com):

776678-09 LabVIEW Professional System for Windows

778553-01 NI Motion Assistant for motion controller programming (Optional)

- NI-MOTION Driver (Included with NI PCI-7390 controller)

Hardware Setup

1. Connect the NI PCI-7390 motion controller to the Yaskawa Sigma II amplifier:

The NI MCA-7790Y accessory kit provides connection between the NI PCI-7390 controller and Sigma II series amplifiers from Yaskawa. To connect a Sigma II amplifier to the PCI-7390 controller,connect a 50-pin cable from the amplifier (PN: 194604-02) to the MCA-7790Y, and connect a SCSI 100-pin cable from the MCA-7790Y to the NI PCI-7390 (included with the MCA-7790Y). Refer toFigure 1 below.

Page 2: NI Tutorial 5908

2/9 www.ni.com

[+] Enlarge Image

Figure 1: NI 7390 Connected to a Yaskawa Sigma II Amplifier

Note: The MCA-7790Y requires a 24 volt power supply that connects to the positive and GND screw terminals.

a. Provide power to the Sigma II amplifier:

For basic applications you can power the Yaskawa Sigma II by connecting the main power pins to an AC power source, refer to Figure 2. For advanced power options such as filtering,alarm shut off, or three-phase power connectivity consult the Sigma II User Manual (www.yaskawa.com) section 3.3.2.

Figure 2: Yaskawa Sigma II Basic Power Connections

b. Connect a Servo Motor to the Yaskawa Sigma II amplifier:

The Yaskawa Sigma II then needs to be connected to a three phase brushless servo motor via the phase pins U, V, and W as shown in Figure 3 below. For encoder feedback the CN2connector on the Yaskawa Amplifier can be connected to a motor using the Servo Amplifier Connector Part Number: 53460-0611.

Page 3: NI Tutorial 5908

3/9 www.ni.com

1. 2. 3. 4. 5.

[+] Enlarge Image

Figure 3: Yaskawa Sigma II Basic Servo Connections

2. Yaskawa Sigma II Configuration:

Configure the Yaskawa Sigma II amplifier for Position Control Mode

Press the MODE/SET button on the display until it reads PnXXX.Use the Data/Enter, up, and down buttons to set the display to: Pn000.Hold down the DATA/Enter button for 1 second until the display reads: n.XXXX.Use the DATA/Enter, up, and down buttons to set the display to: n.0010. Hold down the DATA/Enter button for 1 second to set the Parameter value.

Note: This puts the Sigma II into Position Mode which allows the position commands to come from the Pulse Pin (CN1-7) and the Sign Pin (CN1-11).

Note:   For use with NI PCI 7390 and LabVIEW the Sigma II needs to be used in Position Control Mode. Speed and torque modes are not available through this interface.  To optimize performance,some tuning of the amplifier may be required, reference the Sigma II User's Manual (Chapter 6) for additional information.

NI PCI-7390 Configuration using NI Measurement and Automation Explorer

1. Import "Yaskawa 7390 Settings.xml" file into Measurement and Automation Explorer:

You can import the attached “ file into Measurement and Automation Explorer to automatically configure the NI PCI 7390 (enables Axis 1).Yaskawa 7390 Settings.xml”

[+] Enlarge Image

Figure 4: NI Measurement and Automation Explorer Import Yaskawa Motion Settings

If you do not use this file, the steps in the Appendix section “Manual Yaskawa Configuration Steps” will help you setup the configuration manually.

2. Measurement and Automation Explorer Configuration:

After importing the Yaskawa settings file you will need to set the encoder resolution, motor resolution, and the polarity that corresponds to the type of motor you are using. Most encoders are givenby either two parameters

i. Lines per revolution

Page 4: NI Tutorial 5908

4/9 www.ni.com

1. 2.

3.

ii. Steps or Counts per revolution

A quadrature encoder produces 4 counts (states) per line of resolution, so if the encoder resolution is given in lines/revolution, then you can multiply that by a factor of 4 to get your encoder countsper revolution.

The following adjustments need to be made to your configuration:

Adjust the “Encoder counts per revolution” setting under Encoder Settings to the correct values for your encoder for each affected axisAdjust the “Stepper steps per revolution” setting under Axis Configuration: Stepper Settings Tab to the correct values for your motor. Since Servo motors do not have a “Steps perRevolution” this parameter is used to setup the correct ratio that will allow your motor to operate correctly. For most motors you will need to set this parameter to ¼ of the “Encoder Countsper Revolution”. Adjust the “Stepper Polarity” under Axis Configuration: Stepper Settings Tab to allow positive position commands to move your motor in what you consider the “positive” direction of motion.

[+] Enlarge Image

Figure 5: MAX Encoder Settings

The above adjustments set up the formula the driver will use to calculate position based on the ratio between encoder counts per revolution and motor steps per revolution. When in stepper orP-Command mode you always send your move commands in steps not counts.

Configure moves with NI Motion Assistant (Optional)

NI Motion Assistant is a motion control prototyping utility that will you develop your motion control application quickly. You will use interactive menus to configure your moves. The followinghelpsteps will guide you to configure a simple 1 axis straight line move using NI Motion Assistant.

1. Launch NI Motion by selecting Motion Assistant from the National Instruments directory in the Start Menu.

2. Choose “ ” on the right side of the application and choose “ ”.Add Step Straight Line Move

Page 5: NI Tutorial 5908

5/9 www.ni.com

[+] Enlarge Image

Figure 6: NI Motion Assistant Add Step

3. Select “ ” for the number of axis at the bottom and then choose the axis you would like to control.1D

[+] Enlarge Image

Figure 7: NI Motion Assistant Configure Step

4. Click on the “ ” tab in the “ ” section at the bottom of the Motion Assistant. Enter the amount of steps or revolutions you would like the motor to move. Position Step Setup

5. Finally, click the “ ” button in the toolbar at the top to execute the move. Run

Page 6: NI Tutorial 5908

6/9 www.ni.com

[+] Enlarge Image

Figure 8: NI Motion Assistant Set Position and Run

Export to LabVIEW

Once you have prototyped your moves using NI Motion Assistant export the moves to LabVIEW for further development of your motion control system. Go to the Tools Menu and click “Generate” >> “ ” (as shown in Figure 10 below).Code Generate LabVIEW Diagram

[+] Enlarge Image

Figure 9: NI Motion Assistant Generate LabVIEW Code

An example block diagram can be seen in Figure 11 below. The code is simply executed by clicking the run arrow in the menu bar at the top of LabVIEW.

Page 7: NI Tutorial 5908

7/9 www.ni.com

[+] Enlarge Image

Figure 10: LabVIEW Block Diagram of Motion Assistant Code

You should now have successfully built a LabVIEW application to move a servo motor through a Yaskawa Sigma II Motor Drive. You are now ready to develop advanced applications! Foradditional information visit: ni.com/motion and www.yaskawa.com

Appendix

NI PCI 7390 Motion Controller:

Figure 11: NI PCI 7390

The National Instruments PCI-7390 is a position (pulse) command stepper motion controller with isolation designed for use with amplifiers that accept position (p-) command mode or step (pulse)command input. The NI PCI-7390 has accessories specifically designed for direct connectivity to Yaskawa Sigma II amplifiers. The PCI-7390 provides fully programmable motion control for up tofour independent or coordinated axes of motion. It features dedicated motion I/O for limit and home switches and additional I/O for general-purpose functions such as in-position, inhibit input/drivealarm, and servo ready. You can use the PCI-7390 controller for point-to-point and straight-line vector moves. The NI PCI-7390 also performs arbitrary and complex motion trajectories throughcircular, spherical, or helical interpolation. The NI PCI-7390 uses quadrature encoders for position and velocity feedback (closed-loop only) and provides advanced encoder functions such astrigger (position capture) and breakpoint (position compare).

Yaskawa SGDH Sigma II Motor Amplifier:

Page 8: NI Tutorial 5908

8/9 www.ni.com

Figure 12: SGDH Sigma II Motor Amplifier

The Yaskawa Sigma II Amplifier is a servo motor control solution for automation needs, that cover 30 watts to 55 kW motor output, and input voltages of 110, 230 and 480 VAC. The Sigma IIamplifier can be set to torque, speed, or position control and utilizes serial encoder technology to automatically recognize Sigma II rotary and linear servomotors. Advanced algorithms provide highperformance tuning and suppression of machine resonance. A built-in keypad and serial port allow easy set-up and monitoring of the servo system.

Manual Yaskawa Configuration Steps:

1. The first step in the software configuration is to open up “ ” found in the National Instruments directory on your PC. In Measurement andNI Measurement and Automation ExplorerAutomation Explorer traverse to “ ” >> “ ” >> “ ” >> “ ” so you can now configure the 4 axis of the NI PCI 7390.Devices and Interfaces NI Motion Devices PCI 7390 Default Settings

2. In the “ settings for the axis you would like to configure click on the “ ” tab in the lower middle part of the screen. Axis Configuration” Stepper Settings

i. Set the to Stepper ModeLoop P-Command

ii. Choose “ for the “ based on how your motor and drive configuration. Active Low or Active High” stepper polarity”

iii. Note the Pull In Tries parameter is ignored for P-Command mode.

iv. Set the “Stepper Steps per revolution” to the encoder and motor ratio needed.

[+] Enlarge Image

Figure 13: NI MAX Axis Configuration Stepper Settings

3. Disable any axis that you are not going to use by expanding each axis that you are not going to use, click on “ ”, and choose “ ” (see Figure 5 below). You canAxis Configuration Disablednow setup an axis for movement.

Page 9: NI Tutorial 5908

9/9 www.ni.com

[+] Enlarge Image

Figure 14: NI MAX Axis Configuration Settings

4. Once the settings are in place you can download the settings to the NI PCI 7390 by clicking the “ ” button at the top. You can now test communication to the amplifier by choosingInitializethe “ sub tree and clicking on “ . Select the correct axis and enter the amount of steps or revolutions you would like to move in the “ parameter. Interactive” 1-D Interactive” Target Position”Click the “ button at the top to execute the motor movement. If the move is successful then the “ ” status line, under the “ section, will turn green.Start” Move is complete Axis Status”

[+] Enlarge Image

Figure 15: NI MAX 1-D Interactive Motion Control

Downloads

yaskawa7390settings.xml

LegalThis tutorial (this "tutorial") was developed by National Instruments ("NI"). Although technical support of this tutorial may be made available by National Instruments, the content in this tutorial maynot be completely tested and verified, and NI does not guarantee its quality in any way or that NI will continue to support this content with each new revision of related products and drivers. THISTUTORIAL IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND AND SUBJECT TO CERTAIN RESTRICTIONS AS MORE SPECIFICALLY SET FORTH IN NI.COM'S TERMS OF USE (