NI PXIe-2727 Specifications - National · PDF fileDEVICE SPECIFICATIONS NI PXIe-2727 ... No Connect CH0+ No Connect CH1+ No Connect ... No Connect CH8– No Connect B0– B1– B2

  • Upload
    hoangtu

  • View
    230

  • Download
    6

Embed Size (px)

Citation preview

  • DEVICE SPECIFICATIONS

    NI PXIe-272716-Bit Resistor Module

    This document lists specifications for the NI PXIe-2727 (NI 2727) 16-bit resistor module. Allspecifications are subject to change without notice. Visit ni.com/manuals for the most currentspecifications.

    ContentsAbout These Specifications...................................................................................................... 1

    Input Characteristics......................................................................................................... 2Dynamic Characteristics................................................................................................... 4Trigger Characteristics...................................................................................................... 5Physical Characteristics.................................................................................................... 5Environment......................................................................................................................5Shock and Vibration..........................................................................................................5Compliance and Certifications..........................................................................................6

    Diagrams................................................................................................................................... 8Accessories..............................................................................................................................10

    About These SpecificationsSpecifications characterize the warranted performance of the instrument under the statedoperating conditions.

    Typical Specifications are specifications met by the majority of the instrument under the statedoperating conditions and are tested at 23 C ambient temperature. Typical specifications arenot warranted. The following specifications are typical at 23 C unless otherwise specified.

    All voltages are specified in DC, ACpk, or a combination unless otherwise specified.

    Topology Independent

    Refer to the NI Switches Help at ni.com/manuals for detailed topology information.

    Caution The protection provided by the NI 2727 can be impaired if it is used in amanner not described in this document.

    http://www.ni.com/manualshttp://www.ni.com/manuals

  • Input CharacteristicsNumber of channels 9

    Maximum voltage

    Channel-to-channel 60 VDC, 30 VACrms, CAT I1

    Channel-to-ground 60 VDC, 30 VACrms, CAT I1

    Maximum current 0.3 A (per channel)

    Maximum power 0.25 W (per channel)

    Resistor accuracy 0.5%

    TCR 100 ppm

    Resolution 0.25 steps

    Range 0.25 to 16,320 (per channel)

    Typical channel accuracy

    Channel set between 20 and 40

  • Figure 1. Expected resistance error between 0 and 16,000

    Programmed Resistance Input ()

    Exp

    ecte

    d R

    esis

    tanc

    e E

    rror

    (%

    )

    7

    4

    6

    5

    8

    9

    40002000 6000 8000 10000 12000 14000 16000

    10

    3

    2

    1

    00

    Figure 2. Expected resistance error between 0 and 100

    Programmed Resistance Input ()

    Exp

    ecte

    d R

    esis

    tanc

    e E

    rror

    (%

    )

    70

    40

    60

    50

    80

    90

    2010 30 40 50 60 70 80 90 100

    100

    30

    20

    10

    00

    Figure 3. Expected resistance between 0 and 16,000

    Programmed Resistance Input ()

    Exp

    ecte

    d R

    esis

    tanc

    e O

    utpu

    t (

    )

    6000

    10000

    8000

    12000

    14000

    2000 4000 6000 100008000 12000 14000

    16000

    4000

    2000

    00 16000

    NI PXIe-2727 Specifications | National Instruments | 3

  • Figure 4. Expected resistance between 0 and 50

    Programmed Resistance Input ()

    Exp

    ecte

    d R

    esis

    tanc

    e O

    utpu

    t (

    )

    35

    20

    30

    25

    40

    45

    10 20 30 40

    15

    10

    5

    0

    50

    0 50

    Dynamic CharacteristicsSimultaneous drive limit 161 relays

    Relay operate/release time 250 s

    Note Certain applications may require additional time for proper settling. Refer tothe NI Switches Help at ni.com/manuals for information about including additionalsettling time.

    Typical relay life

    Low power load (

  • Trigger CharacteristicsInput trigger

    Sources PXI trigger lines

    Minimum pulse width 150 ns

    Note The NI 2727 can recognize trigger pulse widths that are less than 150 ns bydisabling digital filtering. For information about disabling digital filtering, refer tothe NI Switches Help at ni.com/manuals.

    Physical CharacteristicsRelay type Reed

    Note NI advises against installing reed relay modules directly adjacent to anembedded controller with a magnetic hard drive because of the sensitivity of reedrelays and the possibility of interference.

    Front panel connector 37-pin D-SUB connector

    DMM port 2 2 Micro-Fit connector

    Power requirement 1.2 W at 3.3 V11 W maximum at 12 V

    Dimensions (L W H) 3U, one slot, PXIe/cPCI module,21.6 2.0 13.0 cm (8.5 0.8 5.1 in.)

    Weight 323 g (11.3 oz)

    EnvironmentOperating temperature 0 C to 55 C

    Storage temperature -20 C to 70 C

    Relative humidity 5% to 85%, noncondensing

    Pollution Degree 2

    Maximum altitude 2,000 m

    Indoor use only.

    Shock and VibrationOperational Shock 30 g peak, half-sine, 11 ms pulse (Tested in

    accordance with IEC 60068-2-27. Test profiledeveloped in accordance withMIL-PRF-28800F.)

    NI PXIe-2727 Specifications | National Instruments | 5

    http://www.ni.com/manuals

  • Random Vibration

    Operating 5 Hz to 500 Hz, 0.3 grmsNonoperating 5 Hz to 500 Hz, 2.4 grms (Tested in accordance

    with IEC 60068-2-64. Nonoperating testprofile exceeds the requirements ofMIL-PRF-28800F, Class 3.)

    Compliance and Certifications

    SafetyThis product is designed to meet the requirements of the following electrical equipment safetystandards for measurement, control, and laboratory use: IEC 61010-1, EN 61010-1 UL 61010-1, CSA 61010-1

    Note For UL and other safety certifications, refer to the product label or the OnlineProduct Certification section.

    Electromagnetic CompatibilityThis product meets the requirements of the following EMC standards for electrical equipmentfor measurement, control, and laboratory use: EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity EN 55011 (CISPR 11): Group 1, Class A emissions AS/NZS CISPR 11: Group 1, Class A emissions FCC 47 CFR Part 15B: Class A emissions ICES-001: Class A emissions

    Note In the United States (per FCC 47 CFR), Class A equipment is intended foruse in commercial, light-industrial, and heavy-industrial locations. In Europe,Canada, Australia, and New Zealand (per CISPR 11), Class A equipment is intendedfor use only in heavy-industrial locations.

    Note Group 1 equipment (per CISPR 11) is any industrial, scientific, or medicalequipment that does not intentionally generate radio frequency energy for thetreatment of material or inspection/analysis purposes.

    Note For EMC declarations and certifications, refer to the Online ProductCertification section.

    6 | ni.com | NI PXIe-2727 Specifications

  • CE Compliance This product meets the essential requirements of applicable European Directives, as follows: 2014/35/EU; Low-Voltage Directive (safety) 2014/30/EU; Electromagnetic Compatibility Directive (EMC)

    Online Product CertificationRefer to the product Declaration of Conformity (DoC) for additional regulatory complianceinformation. To obtain product certifications and the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in theCertification column.

    Environmental ManagementNI is committed to designing and manufacturing products in an environmentally responsiblemanner. NI recognizes that eliminating certain hazardous substances from our products isbeneficial to the environment and to NI customers.

    For additional environmental information, refer to the Minimize Our Environmental Impactweb page at ni.com/environment. This page contains the environmental regulations anddirectives with which NI complies, as well as other environmental information not included inthis document.

    Waste Electrical and Electronic Equipment (WEEE)EU Customers At the end of the product life cycle, all NI products must bedisposed of according to local laws and regulations. For more information abouthow to recycle NI products in your region, visit ni.com/environment/weee.

    RoHS National Instruments (RoHS) National Instruments RoHS ni.com/environment/rohs_china(For information about China RoHScompliance, go to ni.com/environment/rohs_china.)

    NI PXIe-2727 Specifications | National Instruments | 7

    http://www.ni.com/certificationhttp://www.ni.com/certificationhttp://www.ni.com/environmenthttp://www.ni.com/environment/weee.htm

  • DiagramsFigure 5. NI 2727 Connector Pinout

    No Connect

    CH0+No Connect

    CH1+No Connect

    CH2+No Connect

    CH3+No Connect

    CH4+No Connect

    No CH5+No Connect

    CH6+No Connect

    CH7+No Connect

    CH8+No Connect

    Channel Bank Bank

    B0+

    B1+B2+B3+B4+B5+B6+B7+B8+B9+

    B10+B11+B12+B13+B14+B15+B16+B17+

    No ConnectChannel

    CH0No ConnectCH1No ConnectCH2No ConnectCH3No ConnectCH4No ConnectCH5No ConnectCH6No ConnectCH7No ConnectCH8No Connect

    B0B1B2B3B4B5B6B7B8B9B10B11B12B13B14B15B16B17

    1

    2

    3

    4

    HI SENSE

    LO SENSE