NFRC 100/200/500-2010 Simulation Test Report 1/31/2014 WESTLab Report Date: Sunview Doors Limited Manufacturer: Buckingham Eco Patio Door Model/Series: Sliding Glass Door-Sliding Glass Door (XX or OX) Operator Type: Test Size (mm): 500 Zenway Blvd Address: Woodbridge, Ontario L4H 0S7 905-851-1006 ext 242 Phone: Tony Margiotta, CA Contact: Jeff Baker, P.Eng., Certified Simulator Signature of Simulator In-Responsible-Charge: Vinyl (VY) Frame Type: SDL14003-JM WESTLab Report No.: Simulated U-factor: This product line validates using the test for the Buckingham Patio Door. See WESTLab report #SDL14002 for validation product details. Baseline Product for U-Factor Validation Testing: Description: Notes: Physical Test Tolerance: to Sash Type: 1/31/2014 Revision/Addendum Date: The window U-factor, SHGC, VT & CR values presented in this report were determined using the Therm and Window computer programs in full compliance with NFRC 100-2010, 200-2010 and 500-2010, and from information supplied by the manufacturer. This report does not constitute certification of this product and only relates to the fenestration products simulated. Authorized use of any U-factor, SHGC Visible Transmittance and Condensation Resistance ratings may only be granted by the Certification Program Administrator. WESTLab does not imply or claim that the product simulated in this report will perform as stated in actual use conditions. This report is the property of WESTLab and the client, and must not be reproduced, except in full, without written approval from WESTLab and the client. Ratings values included in this report are for submittal to an NFRC-licensed IA are not meant to be used directly for labeling purposes. Only those values identified on a valid Certification Authorization Report (CAR) by an NFRC accredited Inspection Agency (IA) are to be used for labeling purposes. Rounding of values in this report is per NFRC 601 NFRC unit and measurement policy. Disclaimers/Notes: Ken Nittler: 1721 Arroyo Drive, Auburn, CA 95603. Phone: (530) 885-9891, Fax: 885-9892 e-mail: [email protected] Ross DePaola: 3473 Dell Drive, Madison, WI 53718-6629. Phone: (608) 221-9510, Fax: 299-3709 e-mail: [email protected] RECERTIFICATION REPORT NFRC Product Line ID: SDL-K-6 Manufacturer must have the product described above tested by an accredited physical testing laboratory. Physical test window U-factor results must be within the tolerance range listed above. The baseline product simulated U-factor is within 20% or 0.10 of the lowest simulated U-factor listed in the matrix (as allowed by NFRC 100-2010) unless otherwise noted in the "Other Notes and Comments" section. NFRC Standard Size: Note: if the test product is not an NFRC standard size, see the Window mdb file for U-factor calculation. x Jeff Baker: 4 Beck Blvd. Unit 4, Penetang, Ontario L9M 2H3. Phone: (705) 812-0710, Fax: (519) 488-1060 e-mail: [email protected] Report Type: Recertification Vinyl w/ Vertical Members Reinforced (VV)

NFRC 100/200/500-2010 Simulation Test Report · 2016-02-05 · NFRC 100/200/500-2010 Simulation Test Report 1/31/2014 WESTLab Report Date: Manufacturer: Sunview Doors Limited Model/Series:

  • Upload
    others

  • View
    6

  • Download
    1

Embed Size (px)

Citation preview

Page 1: NFRC 100/200/500-2010 Simulation Test Report · 2016-02-05 · NFRC 100/200/500-2010 Simulation Test Report 1/31/2014 WESTLab Report Date: Manufacturer: Sunview Doors Limited Model/Series:

NFRC 100/200/500-2010Simulation Test Report

1/31/2014WESTLab Report Date:

Sunview Doors LimitedManufacturer:

Buckingham Eco Patio DoorModel/Series:

Sliding Glass Door-Sliding Glass Door (XX or OX)Operator Type:

Test Size (mm):

500 Zenway BlvdAddress:

Woodbridge, Ontario L4H 0S7905-851-1006 ext 242Phone:

Tony Margiotta, CAContact:

Jeff Baker, P.Eng., Certified Simulator

Signature of SimulatorIn-Responsible-Charge:

Vinyl (VY)Frame Type:

SDL14003-JMWESTLab Report No.:

Simulated U-factor:

This product line validates using the test for the Buckingham Patio Door.See WESTLab report #SDL14002 for validation product details.

Baseline Product for U-Factor Validation Testing:

Description:

Notes:

Physical Test Tolerance: to

Sash Type:

1/31/2014Revision/Addendum Date:

The window U-factor, SHGC, VT & CR values presented in this report were determined using the Therm and Window computer programs in fullcompliance with NFRC 100-2010, 200-2010 and 500-2010, and from information supplied by the manufacturer. This report does not constitutecertification of this product and only relates to the fenestration products simulated. Authorized use of any U-factor, SHGC Visible Transmittance andCondensation Resistance ratings may only be granted by the Certification Program Administrator.WESTLab does not imply or claim that the product simulated in this report will perform as stated in actual use conditions. This report is the propertyof WESTLab and the client, and must not be reproduced, except in full, without written approval from WESTLab and the client.Ratings values included in this report are for submittal to an NFRC-licensed IA are not meant to be used directly for labeling purposes. Only thosevalues identified on a valid Certification Authorization Report (CAR) by an NFRC accredited Inspection Agency (IA) are to be used for labelingpurposes. Rounding of values in this report is per NFRC 601 NFRC unit and measurement policy.

Disclaimers/Notes:

Ken Nittler: 1721 Arroyo Drive, Auburn, CA 95603. Phone: (530) 885-9891, Fax: 885-9892 e-mail: [email protected] DePaola: 3473 Dell Drive, Madison, WI 53718-6629. Phone: (608) 221-9510, Fax: 299-3709 e-mail: [email protected]

RECERTIFICATIONREPORT

NFRC Product Line ID:SDL-K-6

Manufacturer must have the product described above tested by an accredited physical testing laboratory. Physical test window U-factor resultsmust be within the tolerance range listed above. The baseline product simulated U-factor is within 20% or 0.10 of the lowest simulated U-factorlisted in the matrix (as allowed by NFRC 100-2010) unless otherwise noted in the "Other Notes and Comments" section.

NFRC Standard Size:Note: if the test product is not an NFRCstandard size, see the Window mdb filefor U-factor calculation.

x

Jeff Baker: 4 Beck Blvd. Unit 4, Penetang, Ontario L9M 2H3. Phone: (705) 812-0710, Fax: (519) 488-1060 e-mail: [email protected]

Report Type:Recertification

Vinyl w/ Vertical Members Reinforced (VV)

Page 2: NFRC 100/200/500-2010 Simulation Test Report · 2016-02-05 · NFRC 100/200/500-2010 Simulation Test Report 1/31/2014 WESTLab Report Date: Manufacturer: Sunview Doors Limited Model/Series:

SDL-K-6Product Line ID:Sunview Doors LimitedManufacturer Name:

Sliding Glass Door-Sliding Glass Door (XX or OX)Operator Type:

Buckingham Eco Patio DoorSeries/Model:

SWWCSimulation Lab Code:Vinyl (VY) / Vinyl w/ Vertical Members Reinforced (VV)Frame/Sash Type:

SDL14003-JMSimulation Report #

1/31/2014Simulation Orig Report Date:

1/31/2014Simulation Revision Date:

RecertificationReport Type:

2000mm x 2000mmModel Size:

NFRC Product Line Summary ( Std)

0.3Frame Abs.:

Opt# #Grp'd Description/Code Glass Thicknesses Gap Width(s) Gas Emissivity(sfc) Spacer/Seal Divider U-Factor CR Tint SHGC VT SHGC VT SHGC VTNo Dividers Dividers < 1" Dividers > 1"Note: If options in this matrix are grouped (i.e. there are group ID numbers), the option numbers will not match the NFRC database option numbers

2010

010 2 CLLE366-CL OF-S0.118, 0.118 ARG0.750 0.022(2) 600.29 0.21 0.50 0.19 0.44N,G

011 2 CLLE366-CL OF-S0.158, 0.158 ARG0.688 0.022(2) 590.29 0.21 0.50 0.19 0.43N,G

012 2 CLLE272-CL OF-S0.118, 0.118 ARG0.750 0.042(2) 590.30 0.32 0.55 0.28 0.48N,G

013 2 CLLE272-CL OF-S0.158, 0.158 ARG0.688 0.042(2) 590.29 0.32 0.55 0.28 0.48N,G

014 2 CLCL-LE180 OF-S0.118, 0.118 ARG0.750 0.068(3) 590.30 0.53 0.61 0.47 0.53N,G

015 2 CLCL-LE180 OF-S0.158, 0.158 ARG0.688 0.068(3) 580.30 0.52 0.61 0.46 0.53N,G

016 2 CLGRD63/31-CL OF-S0.118, 0.118 ARG0.750 0.026(2) 600.29 0.24 0.49 0.22 0.43N,G

017 2 CLGRD63/31-CL OF-S0.158, 0.158 ARG0.688 0.026(2) 590.29 0.24 0.48 0.21 0.42N,G

018 2 CLGRD80/70-CL OF-S0.118, 0.118 ARG0.750 0.095(2) 580.31 0.51 0.62 0.45 0.55N,G

019 2 CLGRD80/70-CL OF-S0.158, 0.158 ARG0.688 0.095(2) 580.31 0.50 0.62 0.44 0.54N,G

020 1 CLLE366-i89 OF-S0.118, 0.118 ARG0.750 0.022(2) 0.149(4) 490.25 0.21 0.49N

021 1 CLLE366-i89 OF-S0.158, 0.158 ARG0.688 0.022(2) 0.149(4) 480.25 0.21 0.48N

022 1 CLLE272-i89 OF-S0.118, 0.118 ARG0.750 0.042(2) 0.149(4) 480.25 0.32 0.54N

023 1 CLLE272-i89 OF-S0.158, 0.158 ARG0.688 0.042(2) 0.149(4) 480.25 0.31 0.54N

024 1 CLLE180-i89 OF-S0.118, 0.118 ARG0.750 0.068(2) 0.149(4) 470.26 0.49 0.60N

025 1 CLLE180-i89 OF-S0.158, 0.158 ARG0.688 0.068(2) 0.149(4) 470.26 0.47 0.59N

026 1 CLLE366-CL-LE366 OF-S0.118, 0.118, 0.118 ARG0.313, 0.313 0.022(2) 0.022(5) 650.22 0.19 0.36N

027 1 CLLE366-CL-CL OF-S0.118, 0.118, 0.118 ARG0.313, 0.313 0.022(2) 620.26 0.20 0.46N

028 1 CLLE272-CL-LE272 OF-S0.118, 0.118, 0.118 ARG0.313, 0.313 0.042(2) 0.042(5) 650.23 0.27 0.44N

029 1 CLLE272-CL-CL OF-S0.118, 0.118, 0.118 ARG0.313, 0.313 0.042(2) 620.27 0.30 0.51N

030 1 CLLE180-CL-LE180 OF-S0.118, 0.118, 0.118 ARG0.313, 0.313 0.068(2) 0.068(5) 650.23 0.43 0.54N

031 1 CLCL-CL-LE180 OF-S0.118, 0.118, 0.118 ARG0.313, 0.313 0.068(5) 610.27 0.48 0.56N

032 1 CLGRD63/31-CL-GRD63/31 OF-S0.118, 0.118, 0.118 ARG0.313, 0.313 0.026(2) 0.026(5) 650.22 0.21 0.34N

033 1 CLGRD63/31-CL-CL OF-S0.118, 0.118, 0.118 ARG0.313, 0.313 0.026(2) 620.26 0.23 0.45N

WESTLab Initials:

Matrix Page 1

The Condensation Resistance results obtained from this procedure are for controlled laboratory conditions and do not include the effects of air movement through the specimen, solar radiation, and the thermal bridging that may occur due to the specificdesign and construction of the fenestration system opening. (NFRC 500, Sec. 4.4)

Page 3: NFRC 100/200/500-2010 Simulation Test Report · 2016-02-05 · NFRC 100/200/500-2010 Simulation Test Report 1/31/2014 WESTLab Report Date: Manufacturer: Sunview Doors Limited Model/Series:

SDL-K-6Product Line ID:Sunview Doors LimitedManufacturer Name:

Sliding Glass Door-Sliding Glass Door (XX or OX)Operator Type:

Buckingham Eco Patio DoorSeries/Model:

SWWCSimulation Lab Code:Vinyl (VY) / Vinyl w/ Vertical Members Reinforced (VV)Frame/Sash Type:

SDL14003-JMSimulation Report #

1/31/2014Simulation Orig Report Date:

1/31/2014Simulation Revision Date:

RecertificationReport Type:

2000mm x 2000mmModel Size:

NFRC Product Line Summary ( Std)

0.3Frame Abs.:

Opt# #Grp'd Description/Code Glass Thicknesses Gap Width(s) Gas Emissivity(sfc) Spacer/Seal Divider U-Factor CR Tint SHGC VT SHGC VT SHGC VTNo Dividers Dividers < 1" Dividers > 1"Note: If options in this matrix are grouped (i.e. there are group ID numbers), the option numbers will not match the NFRC database option numbers

2010

034 1 CLGRD80/70-CL-GRD80/70 OF-S0.118, 0.118, 0.118 ARG0.313, 0.313 0.095(2) 0.095(5) 650.24 0.45 0.56N

035 1 CLCL-CL-GRD80/70 OF-S0.118, 0.118, 0.118 ARG0.313, 0.313 0.095(5) 610.27 0.49 0.57N

036 1 CLLE366-LE366-i89 OF-S0.118, 0.118, 0.118 ARG0.313, 0.313 0.022(2) 0.022(4) 0.149(6) 550.20 0.16 0.35N

037 1 CLLE272-LE272-i89 OF-S0.118, 0.118, 0.118 ARG0.313, 0.313 0.042(2) 0.042(4) 0.149(6) 550.21 0.25 0.43N

038 1 CLLE180-CL-i89 OF-S0.118, 0.118, 0.118 ARG0.313, 0.313 0.068(2) 0.149(6) 490.24 0.44 0.55N

039 1 CLLE180-LE180-i89 OF-S0.118, 0.118, 0.118 ARG0.313, 0.313 0.068(2) 0.068(4) 0.149(6) 540.21 0.41 0.53N

040 1 BGLE270-CL ODL BLIND CU-D0.118, 0.118, 0.118 ARG0.813, 0.313 0.037(2) 0.149(6) 560.36 0.27 0.49N

041 1 CLLE366-LE366-CL OF-S0.118, 0.118, 0.118 ARG0.313, 0.313 0.022(2) 0.022(4) 650.22 0.17 0.36N

042 1 CLCL-LE180-LE180 OF-S0.118, 0.118, 0.118 ARG0.313, 0.313 0.068(3) 0.068(5) 650.23 0.45 0.54N

043 2 CLLE366-CL SS-D0.118, 0.118 ARG0.778 0.022(2) 570.30 0.21 0.50 0.19 0.44N,G

044 2 CLLE270-CL SS-D0.118, 0.118 ARG0.778 0.037(2) 570.30 0.29 0.54 0.25 0.47N,G

WESTLab Initials:

Matrix Page 2

The Condensation Resistance results obtained from this procedure are for controlled laboratory conditions and do not include the effects of air movement through the specimen, solar radiation, and the thermal bridging that may occur due to the specificdesign and construction of the fenestration system opening. (NFRC 500, Sec. 4.4)

Page 4: NFRC 100/200/500-2010 Simulation Test Report · 2016-02-05 · NFRC 100/200/500-2010 Simulation Test Report 1/31/2014 WESTLab Report Date: Manufacturer: Sunview Doors Limited Model/Series:

Summary - Frame, IG Unit & Dividers:SDL14003-JMReport #Date: 1/31/2014

Rev: 1/31/2014

Sunview Doors LimitedManufacturer:

Model/Series:

Sliding Glass Door-Sliding Glass Door (XX or OX)Operator Type:

Vinyl (VY)Frame Type:

Frame Description & Comments:

Glazing Description & Comments:

Divider Description & Comments:

Vinyl ExtrusionFrame Core Material:

Vinyl ExtrusionSash Core Material:

Full SashSash Type:

Extruded VinylFrame Clad Type:

Flexible Vinyl (ext & Int)Glazing Seal(s):

Pile Seal, Vinyl Flex, Vinyl BulbWeatherstrip Types:

Non-continuous. Not modeled.Hardware:

Sill Frame comprises up of vinyl and aluminum anodized components. Composite Stiffener located in the Headand Jamb sections - Vision Ecoproducts - Eco Cellulosic Composte (NFRC 101 - Appendix C). Reinforcementis Galvanized Steel and is located in both Upper and Lower Meeting Rail and both Jambs.

Frame Comments:

0.98"-1.003" OAIG OA(s): 3.0mm and 4.0mmGlass Thicknesses:

LE360 (e=0.022), LE272 (e=0.042), LE180 (e=0.068), i89 (e=0.149), Guardian 63/31 (e=0.026),Guardian 80/70 (e=0.095), LE270 (e=0.037)

Low E Products/Sfcs:

Argon 90%Gas Fill and Ratio: Evacuated ChamberFill Method:

Standard SuperSpacer (OF-S), Cardinal XL Steel Spacer (SS-D), Intercept Spacer (CU-D)Spacer Types:

Butyl (OF-S); Silicone and PIB (SS-D); Butyl (CU-D)Spacer Backings:

For DG options, LE products on sfc#2 except LE180 on sfc #3. I89 is on surface #4. For TG options, LEproducts are used on sfc#2 & #5, LE on sfc #2 except LE180 and GRD80/70 on sfc #5 and LE366 on sfc#2&#4 and LE180 on sfc #3&#5. I89 on surface #6.Argon only except for Blind option. Blind option - Intercept spacer offered.

IG Comments:

Internal (painted)Divider 1:

0.217" x 0.709"Dimension (W x D):

NoModeled:

Internal (painted)

0.187" x 0.625"

No

Divider 1 & 2: The rectangular bar is grouped under the contoured bar.Dividers were modeled as per the 3mm gap rule therefore no dividers were modeled.Triples not offered with dividers.

Contoured/Painted Flat Bar/Painted

NoneTB Type:

TB Material:

Type:

Divider 2: Divider 3:

Comments:

Internal Bar Shape/Matl:

Divider Patterns: Res (H x V): x (Per Lite) NFRC Std. Pattern N/A

Buckingham Eco Patio Door

Divider 4:

Vinyl w/ Vertical Members Reinforced (VV)Sash Type:

Vinyl Exterior/InteriorFrame Finish:

7Unique Cross Sections:

All Sections (PS, VF), Jambs (VB)Weatherstrip Locations:

Vinyl Exterior/InteriorSash Finish:

Extruded VinylSash Clad Type:

Steel - All Vertical Sash Members & MRReinforcement:

WESTLab Initials:

Page 5: NFRC 100/200/500-2010 Simulation Test Report · 2016-02-05 · NFRC 100/200/500-2010 Simulation Test Report 1/31/2014 WESTLab Report Date: Manufacturer: Sunview Doors Limited Model/Series:

Summary - Simulation & Other Notes:SDL14003-JMReport #Date: 1/31/2014

Rev: 1/31/2014

Grouping/Simplification Notes & Comments:

Therm 6.3Sim Program Used: 6.3Window Program Vers: 32.0Spectral Data Version:

Example: HF_01.THM (Head Fixed), JV_01.THM (Jamb Vent),Therm File Convention:

C:\- WESTLab\Dropbox\W6\Sunview Patio Doors Ltd\SDL-K-6 SDL14003-JM Buckingham EcoProject File Path:

Divders not Modeled (>3mm gap)Divider File Convention:

Modeled from Drawings providedSpacer Origin:

Assumed nailing fins removed for validation testing.Sim Comments:

Nominal Glass ThicknessType 1:

Divider Grouping (Contoured/Rectangular)Type 2:

Validation Matrix (Victorian and Buckingham and Buckingam Eco PatioType 3:

Validation Matrix (Victorian and Buckingham and Buckingam Eco Patio

0.3Frame Absorptivity:

27/(36), 31/(40)Generic Frame Option #('s):

YesDivider Simplification:

YesGeneric Glass Thickness:

SHGC & VT values were calculated from the SHGC 0 & 1, and VT 0 & 1 Generic Frame optionslisted above.

Comments:

For validation test purposes the 6' Victorian Patio Door (WESTLab Report #SDL14001) is groupedtogether with the Buckingham Patio Door (WESTLab Report #SDL14002) and the Buckingham EcoPatio Door (WESTLab Report #SDL14003). The Buckingham Patio Door (WESTLab Report#SDL14002) is the group leader.

Other Comments:

Type 4:

Type 5:

U-Factor Groupings/Interpretations:

SHGC Simplifications:

Ref/TI:

Ref/TI:

NFRC 100, 4.2.5.D.

NFRC 100, 4.2.4.1

NFRC 100, 4.2.3.1

NFRC 100, 4.2.1.e

Ref/TI:

Ref/TI:

Ref/TI:

Yes - Same Product TypeValidation Test Matrix:

Reference: NFRC 200, Sec. 4.2.3 A.

Reference: NFRC 200, Sec. 4.7

Margaret Koszela, Certified Simulator

Reference: NFRC 200, Sec. 4.2.3 B.

(for SHGC 0 & 1 Table)

Reference: NFRC 200, Table 4-1

Project Simulator:

Simulation Notes & Comments:

Sunview Doors LimitedManufacturer:

Model/Series:

Sliding Glass Door-Sliding Glass Door (XX or OX)Operator Type:

Vinyl (VY)Frame Type:

Buckingham Eco Patio Door

Vinyl w/ Vertical Members Reinforced (VV)Sash Type:

WESTLab Initials:

Page 6: NFRC 100/200/500-2010 Simulation Test Report · 2016-02-05 · NFRC 100/200/500-2010 Simulation Test Report 1/31/2014 WESTLab Report Date: Manufacturer: Sunview Doors Limited Model/Series:

Specialty Products Values SummarySDL14003-JMReport #Date: 1/31/2014

Rev: 1/31/2014

Specialty Products Frame Type 1 - Window5#/(Matrix#):Frame Description: Standard Vinyl Frame

Dividers < 1"No Dividers Dividers > 1"

Frame Description:

Note: Changes in sight-line require additional, unique specialty products information.

ODL Blind OptionDividers < 1"No Dividers Dividers > 1"

Frame Description: N/A

Dividers < 1"No Dividers Dividers > 1"

Frame Description: N/ADividers < 1"No Dividers Dividers > 1"

Calculation Formulas: SHGC = SHGC0 + (SHGCc x (SHGC1 - SHGC0))VT = VTc x (VT1 - VT0)

Note: SHGCc /VTc (center) values must be obtained through thesimulator and approved by the IA. All SHGC/VT values must havea corresponding approved NFRC U-factor.

Sunview Doors LimitedManufacturer:

Model/Series:

Sliding Glass Door-Sliding Glass Door (XX or OX)Operator Type:

Vinyl (VY)Frame Type:

Buckingham Eco Patio Door

Vinyl w/ Vertical Members Reinforced (VV)Sash Type:

27/(36)

Specialty Products Frame Type 2 - Window5#/(Matrix#):

Specialty Products Frame Type 3 - Window5#/(Matrix#):

Specialty Products Frame Type 4 - Window5#/(Matrix#):

31/(40)

0.006652 0.680020

0.000000VT0 VT1

0.673368

SHGC0 SHGC1

0.003496 0.773925

0.000000VT0 VT1

0.770429

SHGC0 SHGC1

0.009596 0.592434

0.000000VT0 VT1

0.582839

SHGC1SHGC0

0.010316 0.617429

0.000000VT0 VT1

0.607114

SHGC0 SHGC1

0.007298 0.706738

0.000000VT0 VT1

0.699440

SHGC0 SHGC1

0.013119 0.534439

0.000000VT0 VT1

0.521320

SHGC1SHGC0

VT0 VT1

SHGC0 SHGC1

VT0 VT1

SHGC0 SHGC1

VT0 VT1

SHGC1SHGC0

VT0 VT1

SHGC0 SHGC1

VT0 VT1

SHGC0 SHGC1

VT0 VT1

SHGC1SHGC0

WESTLab Initials:

Page 7: NFRC 100/200/500-2010 Simulation Test Report · 2016-02-05 · NFRC 100/200/500-2010 Simulation Test Report 1/31/2014 WESTLab Report Date: Manufacturer: Sunview Doors Limited Model/Series:

TYPE 2 PANEL

Width(in) Height(in) Qty

DOOR SIZE 71.5 X 79.5 1

Assembly Part # Cut Size Qty Manufacture

1196 69 1/4 1 Vision Extrusions

1195 79 1/2 2 Vision Extrusions

2691 69 1/4 1 Vision Extrusions

1194 35 3/16 4 Vision Extrusions

1192 75 13/16 2 Vision Extrusions

1193 75 13/16 2 Vision Extrusions

1234 0 0 Vision Extrusions

1232 0 0 Vision Extrusions

3643 69 1/4 1 Vision Eco

3643 79 1/2 2 Vision Eco

72 1/4 4 CARGOWALL LIMITED

EH-9440 0 0 CAN ART

ES-16134 69 1/4 1 CAN ART

26G 69 1/4 1 CARGOWALL LIMITED

1198 33 1/4 1 Vision Extrusions

SUNFPS X 1 SIL PLASTICDPRP2375-63-

GYST 0875 (2 3/8"x7/8") 1 NAPDPRP125063-

GYST 0560 (2 3/8"1/2") 1 NAP

2837 76 5/8 0 Vision Extrusions

SUNHP X 1 SIL PLASTICDPRP125063-

GYST (2 7/8"x1 1/4") 1 NAP

107G01 X 2 NAP

107G02 X 2 Ultrafab

AP 387 79 1/2 4 ANPLEX

21018745WHGF 79 1/2 8 AMESBURY

#1197stl-1032 X 2 FASCO/NAP

A541 3 1/2" 1 Alku Plastic

A542 3 1/2" 1 Alku Plastic

9700 Elite X 1 Fasco

9357FG14 X 1 Fasco

1108665 (8-10x2 1/2") 16 Accurate Fasteners

1067419 (8-15x1") 7 Accurate Fasteners

1115960 (8-15x1/2") 2 Accurate Fasteners

1117709 (8-15x1/2") 1 Accurate Fasteners

335AC X X Fasco/CSL Silicones

335AC X X Fasco/CSL Silicones

Screen 0210-6-WH (35 3/8x76 3/8) 1 TKG

Width(in) Hight(in) Qnt'y

Glass Size 32 X 70 3/4 2

Sash Lock

Reinf.

Header Rice Hull Reinf.

3-Mullion Reinf.

Screen

11/07/2012

Buckingham

Rev 3: July 10, 2012

Description

Frame & Sash

Header

Jambs

Sash T/B

Fixed Panel Support

Dust Plug-Sill (2)

Dust Plug-Sill (1)

Sash Interlock

3-Panel Mullion

4-Panel Operatable Mullion

Sill Component

Frame Component

Jamb Pocket Cover(Fix)

Header Bumper Blind

Dust Plug

Jamb Gasket-Top

Roller Assembly

Sill Bumper Blind

Tapping Screw Flat Head #2 Quadrex Drive Type A

Silicon White

Quadrex PAN HD Zink Plated

Silicon ClearSilicon

Screen Track

Door Track

Sill

Sash Reinf.(16GA Stff Orion)

Jamb Rice Hull Reinf.

Anti Lift Block

Jamb Gasket-Bottom

Bulb Seal-Jamb

Weatherstripping

Fixed Panel Support Addapter

AccessoriesHandle Assembly

Door Lock

Screw

Square Socket /phil Head Wood Screw

Quadrex Flat HD Zink Plated

WESTLab Report #SDL14003

Page 8: NFRC 100/200/500-2010 Simulation Test Report · 2016-02-05 · NFRC 100/200/500-2010 Simulation Test Report 1/31/2014 WESTLab Report Date: Manufacturer: Sunview Doors Limited Model/Series:

WESTLab Report #SDL14003

Page 9: NFRC 100/200/500-2010 Simulation Test Report · 2016-02-05 · NFRC 100/200/500-2010 Simulation Test Report 1/31/2014 WESTLab Report Date: Manufacturer: Sunview Doors Limited Model/Series:

PRELIMINARYA1

VISION TM

This document and the information contained is owned by and proprietary to Vision Extrusions Limited. By receipt hereof, the holder agrees not to use the information, disclose it to any third parties nor reproduce this document without the prior written consent of Vision

Extrusions Limited, and agrees to return this document forthwith upon request.

A

B

DETAIL "B" (SCALE 2:1)

ba

ab

a

a

DETAIL "A" (SCALE 2:1)

DETAIL "C" (SCALE 2:1)

WALL THICKNESS:NOMINAL = 0.075" = 0.055" = 0.090"

NOTE: BREAK ALL SHARP CORNERS WITH 0.015" RADII

RADII:a = 0.010"b = 0.020unmarked = 0.015"

C

D

INTERIOR SCREW PORT REMOVEDB1

REAR SCREW PORT THICKENED FOR MOUNTING C1LOCKING HARDWARE - 8° SLOPED ADDED TO WALL

ba

ab

a

a

DETAIL "D" (SCALE 2:1)

WESTLab Report #SDL14003

Page 10: NFRC 100/200/500-2010 Simulation Test Report · 2016-02-05 · NFRC 100/200/500-2010 Simulation Test Report 1/31/2014 WESTLab Report Date: Manufacturer: Sunview Doors Limited Model/Series:

WESTLab Report #SDL14003

Page 11: NFRC 100/200/500-2010 Simulation Test Report · 2016-02-05 · NFRC 100/200/500-2010 Simulation Test Report 1/31/2014 WESTLab Report Date: Manufacturer: Sunview Doors Limited Model/Series:

WESTLab Report #SDL14003

WESTLab
Text Box
Page 12: NFRC 100/200/500-2010 Simulation Test Report · 2016-02-05 · NFRC 100/200/500-2010 Simulation Test Report 1/31/2014 WESTLab Report Date: Manufacturer: Sunview Doors Limited Model/Series:

WESTLab Report #SDL14003

WESTLab
Text Box
Page 13: NFRC 100/200/500-2010 Simulation Test Report · 2016-02-05 · NFRC 100/200/500-2010 Simulation Test Report 1/31/2014 WESTLab Report Date: Manufacturer: Sunview Doors Limited Model/Series:

WESTLab Report #SDL14003

WESTLab
Text Box
Page 14: NFRC 100/200/500-2010 Simulation Test Report · 2016-02-05 · NFRC 100/200/500-2010 Simulation Test Report 1/31/2014 WESTLab Report Date: Manufacturer: Sunview Doors Limited Model/Series:

WESTLab Report #SDL14003

WESTLab
Text Box
Page 15: NFRC 100/200/500-2010 Simulation Test Report · 2016-02-05 · NFRC 100/200/500-2010 Simulation Test Report 1/31/2014 WESTLab Report Date: Manufacturer: Sunview Doors Limited Model/Series:

WESTLab Report #SDL14003

WESTLab
Text Box
Page 16: NFRC 100/200/500-2010 Simulation Test Report · 2016-02-05 · NFRC 100/200/500-2010 Simulation Test Report 1/31/2014 WESTLab Report Date: Manufacturer: Sunview Doors Limited Model/Series:

WESTLab Report #SDL14003

WESTLab
Text Box
Page 17: NFRC 100/200/500-2010 Simulation Test Report · 2016-02-05 · NFRC 100/200/500-2010 Simulation Test Report 1/31/2014 WESTLab Report Date: Manufacturer: Sunview Doors Limited Model/Series:

WESTLab Report #SDL14003

WESTLab
Text Box
Page 18: NFRC 100/200/500-2010 Simulation Test Report · 2016-02-05 · NFRC 100/200/500-2010 Simulation Test Report 1/31/2014 WESTLab Report Date: Manufacturer: Sunview Doors Limited Model/Series:

WESTLab Report #SDL14003

Page 19: NFRC 100/200/500-2010 Simulation Test Report · 2016-02-05 · NFRC 100/200/500-2010 Simulation Test Report 1/31/2014 WESTLab Report Date: Manufacturer: Sunview Doors Limited Model/Series:

WESTLab Report #SDL14003

WESTLab
Text Box
Page 20: NFRC 100/200/500-2010 Simulation Test Report · 2016-02-05 · NFRC 100/200/500-2010 Simulation Test Report 1/31/2014 WESTLab Report Date: Manufacturer: Sunview Doors Limited Model/Series:

D–2

Muntin BarAluminum: Painted, Mill Finish, Clear & Color-InTM Anodized

Note: Available in pre-cut lengths and pre-notched; tutone and post-painted. Custom colors also available.

Please see terms & conditions of sale.Copyright © 2006 Allmetal, Inc.

Part numbers shown are standard white color.† Available in tutone. Please see Color Selection Chart located in front of catalog.Δ Part number shown is Dark Bronze Anodized Color.* Part number shown is Clear Anodized. **Part number shown is white welded.

A

B

TOLERANCEA, ± .005 (.127mm)B, ± .005 (.127mm)

SPECIAL NOTICECleaning and Handling of Muntin Bar

We recommend muntin bar to be wiped clean before installation into an insulating glass unit. A household grade liquid cleaner may be used for this purpose.

To avoid breakdown of painted surfaces, do not use M.E.K., Triethane, Alcohol or like substances for the cleaning of painted muntin bar.

When machining and processing muntin bar in yourplant, keep saw tables and work areas free of saw cutfilings to avoid scratching the painted surfaces.

1/8 x .610 219697 200 25333/16 x 9/16† 119320 150 19003/16 x .610† 119705 125 15833/16 x 5/8† 120874 125 15833/16 x 3/4 122909 110 1393

3/16 x 13/16 123618 110 13933/16 x 1 123823 85 1076

1/4 x 9/16 119427 135 17101/4 x 5/8† 121410 120 15201/4 x 3/4 123063 95 1203

1/4 x 13/16 215017 95 12031/4 x 1 123836 70 887

1/4 x 1 1/4 123856 51 6465/16 x 1 210318 60 684

3/8 x 5/8 121468 90 11403/8 x 3/4 123088 75 950

3/8 x 13/16 215016 70 8873/8 x 7/8 123797 55 697

3/8 x 1 201968 55 6963/8(.375) x 3/8 205591 140 1773

7/16 x 3/8 119016 115 14577/16 x 3/8 216500** 115 14577/16 x 1/2 213045 88 11157/16 x 5/8 Δ 214621 65 8231/2 x 3/4* 201043 50 633

1/2 x 1 203710 40 506

Packaging Information

Muntin Bar Size Part #Pieces Per

Shipping Carton12' 8" Lengths

Lineal Feet PerShipping Carton

12' 8" Lengths

Specification In Inches

Muntin Bar Size A B

1/8 x .610 .125 .6103/16 x 9/16† .187 .5513/16 x .610† .187 .6103/16 x 5/8† .187 .6303/16 x 3/4† .187 .775

3/16 x 13/16† .187 .8013/16 x 1 .187 1.000

1/4 x 9/16 .235 .5621/4 x 5/8 † .235 .6251/4 x 3/4 .235 .765

1/4 x 13/16 .235 .8011/4 x 1 .235 1.000

1/4 x 1 1/4 .235 1.2505/16 x 1 .312 1.000

3/8 x 5/8 † .325 .6253/8 x 3/4 .325 .750

3/8 x 13/16 .325 .8013/8 x 7/8 .325 .875

3/8 x 1 .325 1.0003/8(.375) x 3/8 .375 .375

7/16 x 3/8 .438 .3757/16 x 3/8 .438 .3757/16 x 1/2 .438 .5007/16 x 5/8 Δ .438 .6251/2 x 3/4* .500 .750

1/2 x 1 .500 1.000

Material thickness: .0185

WESTLab Report #SDL14003

WESTLab
Typewritten Text
WESTLab
Cross-Out
Page 21: NFRC 100/200/500-2010 Simulation Test Report · 2016-02-05 · NFRC 100/200/500-2010 Simulation Test Report 1/31/2014 WESTLab Report Date: Manufacturer: Sunview Doors Limited Model/Series:

E –2

Contour Muntin BarAluminum: Painted, Mill Finish, Clear & Color-InTM Anodized

Please see terms & conditions of sale.Copyright © 2006 Allmetal, Inc.

Part numbers shown are standard white color.Available in solid & tutone colors. Please see Color Selection Chart located in front of catalog.

Material Thickness: .016: 5.5 x 18mm and 8 x 18mm..0185: 8 x 25mm.

TOLERANCEA, ± .005 (.127mm)B, ± .005 (.127mm)

5.5 x 18 124040 170 21538 x 18 123911 120 15208 x 25 124307 84 1064

5.5 x 18 .217 .7098 x 18 .315 .7098 x 25 .315 .984

Packaging Information

Muntin Bar Size Millimeter

Part #Pieces Per

Shipping Carton12' 8" Lengths

Lineal Feet PerShipping Carton12' 8" Lengths

Specification In Inches

Muntin Bar Size Millimeter

A B

A

B

Note: Available in pre-cut lengths and pre-notched; tutone and post-painted. Custom colors also available.Painted seam available in limited colors upon request.

SPECIAL NOTICECleaning and Handling of Muntin Bar

We recommend muntin bar to be wiped clean before installation into an insulating glass unit. A household grade liquid cleaner may be used for this purpose.

To avoid breakdown of painted surfaces, do not use M.E.K., Triethane, Alcohol or like substances for the cleaning of painted muntin bar.

When machining and processing muntin bar in yourplant, keep saw tables and work areas free of saw cutfilings to avoid scratching the painted surfaces.

WESTLab Report #SDL14003

WESTLab
Cross-Out
Page 22: NFRC 100/200/500-2010 Simulation Test Report · 2016-02-05 · NFRC 100/200/500-2010 Simulation Test Report 1/31/2014 WESTLab Report Date: Manufacturer: Sunview Doors Limited Model/Series:

Super Spacer® Standard Super Spacer® Standard is extruded as a flexible organic foam warm edge spacer. Its polymer EPDM (ethylene-propylene-diene-monomer) is well-known in the industry for its excellent resistance to ozone, weathering, water and aging, while maintaining its flexibility through wide changes in temperature and barometric pressure.

With its multi-layer vapor barrier and acrylic adhesive, Super Spacer provides superior argon gas retention and optimal thermal performance. Its all foam construction is 950 times less conductive than aluminum spacer systems, resulting in its industry-leading condensation resistance.

Super Spacer Standard has an aesthetically pleasing narrow sightline and is part of the TrueWARM® family of Edgetech window spacer products. And, because it's Super Spacer, you can expect windows that are energy efficient and long lasting. Insulating glass units built with Standard Super Spacer backed by a butyl secondary seal have passed more than 60 weeks of P-1 durability testing – the industry’s toughest test! Experts estimate that one week in the P-1 chamber is equivalent to approximately one year of field performance.

Standard Sizes and Options:

Spacer Sizes : Standard Super Spacer is available in a standard 3/16 inch (5 mm) thickness and a full range of spacer widths from 3/16 inch (5 mm) to 3/4 inch (19 mm).

Standard Color: Charcoal grey.

0.188”

0.188”

Butyl (typ)

Insulating Glass Unit

OA/Gap Width Varies

Application Detail

Material used for SuperSpacer Standard:

Edgetech-Super Spacer Standard (EPDM), k = 0.127 Spacer code: ZE-S This material is listed in NFRC 101, Appendix C

WESTLab Report #SDL14003

WESTLab
Typewritten Text
WESTLab
Text Box
OF-S
Page 23: NFRC 100/200/500-2010 Simulation Test Report · 2016-02-05 · NFRC 100/200/500-2010 Simulation Test Report 1/31/2014 WESTLab Report Date: Manufacturer: Sunview Doors Limited Model/Series:

XL Edge Simulation Model The purpose of this guide is to help properly model the XL Edge seal system when performing Therm window simulations. XL Edge geometry. Shown here is the proper XL Edge geometry that should be used for thermal models. This geometry is also included within the attached XL Edge.dxf CAD file. Some important items are: - PIB thickness is 0.015”. - Spacer back even with glass edge. - Stainless steel thickness is 0.0045” for most airspaces.

Thermal conductivity The following thermal conductivity values should be used when modeling XL Edge. - Silicone: 0.202 BTU/hr-ft-F (0.350 W/m-K) - PIB [ADCO PIB-8 HSNB Gray]: 0.089 BTU/hr-ft-F (0.155 W/m-K) - Desiccant [desiccant-loose fill]: 0.017 BTU/hr-ft-F (0.030 W/m-K) - Spacer [Cardinal Stainless Steel]: 8.197 BTU/hr-ft-F (14.187 W/m-K) Cardinal’s stainless steel alloy spacer and ADCO PIB have a lower thermal conductivity than the default values listed in the NFRC 101-2010EOA1.pdf document “Procedure for Determining Thermophysical Properties of Materials for Use in NFRC – Approved Software Programs”. For specific information on the NFRC “Procedure for Determining Thermophysical Properties of Materials for Use in NFRC – Approved Software Programs”, please go to the following web site. http://www.nfrc.org/documents/NFRC101-2010E0A1.pdf

WESTLab Report #SDL14003

Page 24: NFRC 100/200/500-2010 Simulation Test Report · 2016-02-05 · NFRC 100/200/500-2010 Simulation Test Report 1/31/2014 WESTLab Report Date: Manufacturer: Sunview Doors Limited Model/Series:

WESTLab Report #SDL14003

Page 25: NFRC 100/200/500-2010 Simulation Test Report · 2016-02-05 · NFRC 100/200/500-2010 Simulation Test Report 1/31/2014 WESTLab Report Date: Manufacturer: Sunview Doors Limited Model/Series:

WARMEDGE BLIND

WARMEDGE BLINDVERTICAL CROSS SECTION

HORIZONTAL CROSS SECTION

PVC ALUMINUM

ALUMINUM

PVC

ALUMINUM

PVC

ALUMINUM

PVC

PLASTICPLASTIC

WARMEDGE SPACERTIN PLATE COLDROLLED STEEL

1/8" GLASS

WARMEDGE BLINDVERTICAL CROSS SECTION

UNIT DIM A 64 2" 48 1 1/2" 36 1 1/8"

EXTERIOR

INTERIOR

INTERIOR EXTERIOR

EXTERIORINTERIOR

LOW-E SURFACE

LOW-E SURFACE

DATE 6/21/10

ALUMINUM

1/8" GLASS

WARMEDGE DUAL GLAZED BLIND SECTIONS

ODL

CO

NFID

ENTIA

L

1.063 IG

DIM A

0.813 AIR GAP

WESTLab Report #SDL14003