NFPA 2112Round Robin Manikin Testing

NFPA 2112 Thermal Manikin Task GroupApril 29th, 2016

Page 2: NFPA Round Robin Manikin Testing...95% Confidence Interval Prediction Mean: 11.37% Lower‐95% Upper‐95% 9.41% 13.33% North American Labs: ASTM F1930‐2002 Round Robin Results 3

Issue• In recent years the burn injury predictions have started to differ significantly more than in the past

Test Results for 4.5 oz (154 g/m2) Nomex III A with underwear

Test Method ASTM F1930 -11

Results from Alberta (TPBI) 40.8 %

Results from DuPont (TPBI)

20 %

Results from NCSU (TPBI)

37 %

Page 3: NFPA Round Robin Manikin Testing...95% Confidence Interval Prediction Mean: 11.37% Lower‐95% Upper‐95% 9.41% 13.33% North American Labs: ASTM F1930‐2002 Round Robin Results 3

NFPA 2112 Task Group Request• Using the same fabrics and test procedure

– Determine the expected differences between laboratories performing NFPA 2112 testing

• Propose language that might improve agreement between labs

Page 4: NFPA Round Robin Manikin Testing...95% Confidence Interval Prediction Mean: 11.37% Lower‐95% Upper‐95% 9.41% 13.33% North American Labs: ASTM F1930‐2002 Round Robin Results 3

Task Group Language Proposed to NFPA 2112– 3 second nude calibration exposure

• Average incident heat flux calculated from one to three seconds

• Numerical fitting function not to be used to calculate incident heat flux

• Average incident heat flux is greater than or equal to 79 kw/m2 at 1 second mark

– In situ testing at 4, 8, and 12kW/m2

• 6 sensors to be verified (right and left arms and legs, chest and back)

• 4, 8, and 12kW/m2 levels

Page 5: NFPA Round Robin Manikin Testing...95% Confidence Interval Prediction Mean: 11.37% Lower‐95% Upper‐95% 9.41% 13.33% North American Labs: ASTM F1930‐2002 Round Robin Results 3

2011 ISO Round Robin Data

ISO 13506 Results Section 9.5.3120 s data acquisition

0

10

20

30

40

50

60

70

1 2 3 4 5 6 7Laboratory

Perc

ent U

nder

Gar

men

t Sec

ond

Deg

ree

or W

orse

Page 6: NFPA Round Robin Manikin Testing...95% Confidence Interval Prediction Mean: 11.37% Lower‐95% Upper‐95% 9.41% 13.33% North American Labs: ASTM F1930‐2002 Round Robin Results 3

NFPA 2112 Round Robin Testing 2015– Six fabrics tested

• Fabric A: 4.5 osy Aramid• Fabric B: 5.8 osy FR Modacrylic/Aramid• Fabric C: 3.4 osy Aramid• Fabric D: 6.0 osy Aramid• Fabric E: 7.5 osy FR Cotton• Fabric F: 6.5 osy FR Cotton blend

– Three Second Exposure, with 100% cotton t‐shirt and briefs

Page 7: NFPA Round Robin Manikin Testing...95% Confidence Interval Prediction Mean: 11.37% Lower‐95% Upper‐95% 9.41% 13.33% North American Labs: ASTM F1930‐2002 Round Robin Results 3

Round Robin Results– Five Labs Participated

• University of Alberta• DuPont Richmond• North Carolina State University• Aitex• BTTG

– Results Anonymized for the five labs• Labs 3 and 4 compliant with proposed task group language• Labs 1, 2, and 5 not compliant with proposed task group language

Page 8: NFPA Round Robin Manikin Testing...95% Confidence Interval Prediction Mean: 11.37% Lower‐95% Upper‐95% 9.41% 13.33% North American Labs: ASTM F1930‐2002 Round Robin Results 3

Round Robin Results‐Analysis

– Display Results– Identify any outliers– Compare labs results vs. fabric types– Can each lab distinguish between fabric types

Page 9: NFPA Round Robin Manikin Testing...95% Confidence Interval Prediction Mean: 11.37% Lower‐95% Upper‐95% 9.41% 13.33% North American Labs: ASTM F1930‐2002 Round Robin Results 3

Round Robin Results‐All Labs

010203040506070

4.5 osy Aramid 5.8 osy FRModacrylic/Aramid

3.4 osy Aramid 6.0 osy Aramid 7.5 osy FR Cotton 6.5 osy FR CottonBlend

Overall % Bod

y Bu

rn

ALL LABS AVERAGE BURN INJURY PREDICTIONS

Lab #1 Lab 2 Lab 3 Lab 4 Lab 5

Page 10: NFPA Round Robin Manikin Testing...95% Confidence Interval Prediction Mean: 11.37% Lower‐95% Upper‐95% 9.41% 13.33% North American Labs: ASTM F1930‐2002 Round Robin Results 3

Test Method ASTM F1930- 00 ASTM F1930 -11

Skin thicknesses μm50/1500/10000

(based on whole body)

75/1125/3885(based on forearm)

Results from Alberta (TPBI) 47.2 % 40.8 %

Results from DuPont (TPBI)

36 % 20 %

Results from NCSU (TPBI)

41 % 37 %

reduction in reported value Alberta: 6.4 %

reduction in reported value DuPont: 16 %

reduction in reported value NCSU: 4 %

Test Results for 4.5 oz (154 g/m2) Nomex III A with underwear using different skin properties, 3 sec. exposure at 84 kW/m2. Percent 2nd degree or worse, including head.

* Slide from “ASTM New Orleans LA, January 1st, 2015” Presentation by Douglas Dale, University of Alberta

Page 11: NFPA Round Robin Manikin Testing...95% Confidence Interval Prediction Mean: 11.37% Lower‐95% Upper‐95% 9.41% 13.33% North American Labs: ASTM F1930‐2002 Round Robin Results 3

Lab Results Results for Fabric A‐(4.5 osy Aramid)

Page 12: NFPA Round Robin Manikin Testing...95% Confidence Interval Prediction Mean: 11.37% Lower‐95% Upper‐95% 9.41% 13.33% North American Labs: ASTM F1930‐2002 Round Robin Results 3

95% Confidence Interval Prediction

Mean‐36.62%Lower‐95% Upper‐95%33.77% 39.46%

Lab Results (1‐4) for Fabric A (4.5 osy Aramid)

Lab Lab p‐Value4 1 0.0279*4 2 0.07873 1 0.10383 2 0.26704 3 0.65202 1 0.9833

Page 13: NFPA Round Robin Manikin Testing...95% Confidence Interval Prediction Mean: 11.37% Lower‐95% Upper‐95% 9.41% 13.33% North American Labs: ASTM F1930‐2002 Round Robin Results 3

Lab Results Results for Fabric B‐(5.8osy Modacrylic/Aramid)

Page 14: NFPA Round Robin Manikin Testing...95% Confidence Interval Prediction Mean: 11.37% Lower‐95% Upper‐95% 9.41% 13.33% North American Labs: ASTM F1930‐2002 Round Robin Results 3

95% Confidence Interval Prediction

Mean‐19.70%Lower‐95% Upper‐95%14.68% 24.73%

Lab Results (1‐4) for Fabric B (5.8osy Modacrylic/Aramid)

Lab Lab p‐Value3 2 <.0001*4 2 0.0001*3 1 0.0027*4 1 0.0095*1 2 0.07403 4 0.9404

Page 15: NFPA Round Robin Manikin Testing...95% Confidence Interval Prediction Mean: 11.37% Lower‐95% Upper‐95% 9.41% 13.33% North American Labs: ASTM F1930‐2002 Round Robin Results 3

95% Confidence Interval Prediction

Mean‐48.79%Lower‐95% Upper‐95%47.76% 49.82%

Lab Results (1‐4) for Fabric C (3.4osy Aramid)

Lab Lab p‐Value4 2 0.0181*3 2 0.08401 2 0.28764 1 0.37984 3 0.65673 1 0.9203

Page 16: NFPA Round Robin Manikin Testing...95% Confidence Interval Prediction Mean: 11.37% Lower‐95% Upper‐95% 9.41% 13.33% North American Labs: ASTM F1930‐2002 Round Robin Results 3

Lab Results Results for Fabric C‐(3.4osy Aramid)

Page 17: NFPA Round Robin Manikin Testing...95% Confidence Interval Prediction Mean: 11.37% Lower‐95% Upper‐95% 9.41% 13.33% North American Labs: ASTM F1930‐2002 Round Robin Results 3

Lab Results (1‐4) Results for Fabric D‐(6.0osy Aramid)

Page 18: NFPA Round Robin Manikin Testing...95% Confidence Interval Prediction Mean: 11.37% Lower‐95% Upper‐95% 9.41% 13.33% North American Labs: ASTM F1930‐2002 Round Robin Results 3

95% Confidence Interval Prediction

Mean‐19.51%Lower‐95% Upper‐95%15.24% 23.77%

Lab Results (1‐4) for Fabric D (6.0osy Aramid)

Lab Lab p‐Value4 1 <.0001*4 2 <.0001*4 3 0.0002*3 1 0.0019*3 2 0.0064*2 1 0.7342

Page 19: NFPA Round Robin Manikin Testing...95% Confidence Interval Prediction Mean: 11.37% Lower‐95% Upper‐95% 9.41% 13.33% North American Labs: ASTM F1930‐2002 Round Robin Results 3

Lab Results (1‐4) Results for Fabric E‐(7.5osy FR Cotton)

Page 20: NFPA Round Robin Manikin Testing...95% Confidence Interval Prediction Mean: 11.37% Lower‐95% Upper‐95% 9.41% 13.33% North American Labs: ASTM F1930‐2002 Round Robin Results 3

95% Confidence Interval Prediction

Mean‐27.56%Lower‐95% Upper‐95%20.85% 34.07%

Lab Results (1‐4) Results for Fabric E‐(7.5osy FR Cotton)

Lab Lab p‐Value2 1 0.0037*4 1 0.0061*3 1 0.11582 3 0.12124 3 0.21162 4 0.9759

Page 21: NFPA Round Robin Manikin Testing...95% Confidence Interval Prediction Mean: 11.37% Lower‐95% Upper‐95% 9.41% 13.33% North American Labs: ASTM F1930‐2002 Round Robin Results 3

Lab Results (1‐4) Results for Fabric F‐(6.5osy FR Cotton Blend)

Page 22: NFPA Round Robin Manikin Testing...95% Confidence Interval Prediction Mean: 11.37% Lower‐95% Upper‐95% 9.41% 13.33% North American Labs: ASTM F1930‐2002 Round Robin Results 3

95% Confidence Interval Prediction

Mean‐30.80%Lower‐95% Upper‐95%23.30% 38.31%

Lab Results (1‐4) Results for Fabric F‐(6.5osy FR Cotton Blend)

Lab Lab p‐Value4 1 0.0003*2 1 0.0012*3 1 0.0105*4 3 0.06132 3 0.34374 2 0.6058

Page 23: NFPA Round Robin Manikin Testing...95% Confidence Interval Prediction Mean: 11.37% Lower‐95% Upper‐95% 9.41% 13.33% North American Labs: ASTM F1930‐2002 Round Robin Results 3

Can a Lab Distinguish Between the Fabrics?

Page 24: NFPA Round Robin Manikin Testing...95% Confidence Interval Prediction Mean: 11.37% Lower‐95% Upper‐95% 9.41% 13.33% North American Labs: ASTM F1930‐2002 Round Robin Results 3

Can a Lab Distinguish Between the Fabrics?Lab 1 Lab 2 Lab 3 Lab 4

Lab 5

Page 25: NFPA Round Robin Manikin Testing...95% Confidence Interval Prediction Mean: 11.37% Lower‐95% Upper‐95% 9.41% 13.33% North American Labs: ASTM F1930‐2002 Round Robin Results 3

Historical Perspective North American LabsASTM 2002 vs. NFPA 2112‐2015 Round Robin

Page 26: NFPA Round Robin Manikin Testing...95% Confidence Interval Prediction Mean: 11.37% Lower‐95% Upper‐95% 9.41% 13.33% North American Labs: ASTM F1930‐2002 Round Robin Results 3

95% Confidence Interval Prediction

Mean: 11.37%Lower‐95% Upper‐95%9.41% 13.33%

North American Labs: ASTM F1930‐2002 Round Robin Results3 second exposure, no underwear

95% Confidence Interval Prediction

Mean: 28.03Lower‐95% Upper‐95%20.53% 35.54%

95% Confidence Interval Prediction

Mean: 35.62Lower‐95% Upper‐95%28.46% 42.78%

FR Cotton, 9 osy Aramid, 6 osy PBI/Kevlar, 4.5 osy

Lab Lab p‐ValueK             P 0.0178*N            P 0.1036K            N 0.3741

Lab Lab p‐ValueK            P 0.0086*K           N 0.0249*N           P 0.6219

Lab Lab p‐ValueK             P 0.0021*K            N 0.0033*N            P 0.8560

Page 27: NFPA Round Robin Manikin Testing...95% Confidence Interval Prediction Mean: 11.37% Lower‐95% Upper‐95% 9.41% 13.33% North American Labs: ASTM F1930‐2002 Round Robin Results 3

North American Labs: NFPA 2112‐2015 Round Robin Results3 second exposure, with underwear

Fabric A: 4.5 osy Aramid Fabric B: FR Modacrylic/Aramid Fabric C: 3.4 osy Aramid

95% Confidence Interval PredictionMean: 38.08%

Lower‐95% Upper‐95%35.69% 40.46%

95% Confidence Interval PredictionMean: 20.72

Lower‐95% Upper‐95%14.37% 27.07%

95% Confidence Interval PredictionMean: 48.8

Lower‐95% Upper‐95%47.45% 50.14%

Lab Lab p‐Value4           2        <.0001*3           2         0.0007*4           3         0.0103*

Lab Lab p‐Value3           2 <.0001*4           2 <.0001*3           4 0.7954

Lab       Lab p‐Value4             2 0.0207*3             2 0.07784             3 0.5420

Page 28: NFPA Round Robin Manikin Testing...95% Confidence Interval Prediction Mean: 11.37% Lower‐95% Upper‐95% 9.41% 13.33% North American Labs: ASTM F1930‐2002 Round Robin Results 3

North American Labs: NFPA 2112‐2015 Round Robin Results3 second exposure, with underwear

Fabric D: 6.0 osy Aramid Fabric E: 7.5 osy FR Cotton Fabric F: 6.5 osy FR Cotton Blend

95% Confidence Interval PredictionMean: 21.5%

Lower‐95% Upper‐95%16.46% 26.56%

95% Confidence Interval PredictionMean: 32.01%

Lower‐95% Upper‐95%26.28% 37.74%

95% Confidence Interval PredictionMean: 36.47%

Lower‐95% Upper‐95%31.25% 41.69%

Lab Lab p‐Value4          2            <.0001*4          3 0.0002*3          2 0.0040*

Lab Lab p‐Value2          3 0.14424          3 0.22502          4 0.9348

Lab Lab p‐Value4          3 0.07732          3 0.31894          2 0.5336

Page 29: NFPA Round Robin Manikin Testing...95% Confidence Interval Prediction Mean: 11.37% Lower‐95% Upper‐95% 9.41% 13.33% North American Labs: ASTM F1930‐2002 Round Robin Results 3

Conclusion