Series K8DV directly operated solenoid valves with separating diaphragm
Series K directly operated solenoid valves
Series 8 pneumaticallyand electropneumatically operated valves
Series VNR unidirectional cartridge valve
Series TC1-V 2/2-way shut-off micro-valve
Series AP directly operated proportional valves
Series CP directly operated proportional valves
Series TC-1R cartridge pressure regulator
News 2017
93-1
500-
0GB
027
11/
2016
Camozzi’s reliabilityfor your productivity
News 2017
Product presentation
Control Pag
Series K8DV directly operated solenoid valves with separating diaphragm 4
Series K directly operated solenoid valves 6
Series 8 pneumatically and electropneumatically operated valves 8
Series VNR unidirectional cartridge valve 12
Series TC1-V 2/2-way shut-off micro-valve 14
Series AP directly operated proportional valves 16
Series CP directly operated proportional valves 24
Treatment Pag
Series TC1-R cartridge pressure regulator 30
Also this year Camozzi has enlarged its range with solutions that focus on increased
performance and productivity of the applications at its clients, maintaining a constant
quality level and assuring maximum reliability even in very complex conditions.
To this purpose, the Series K valves in the 2/2 version, the Series K8DV with
separating diaphragm, the new Series 8 cartridge valves, the Series AP valves with
proportional technology in the flanged version and revised CP version in the sizes 16
and 20 mm were developed in order to further optimize electric connections. Besides
the products above, we find the new Series TC1-V shut off micro-valve, the VNRC5
unidirectional cartridge valves and the new regulator TC1-R.
4
> VERY COMPACT DESIGN AND REDUCED WEIGHT
> HIGH FLOW PERFORMANCES
> VERY LOW INTERNAL VOLUME
> SUITABLE TO BE APPLIED IN MEDICAL EQUIPMENT AND ANALYTICAL INSTRUMENTS
Directly operated solenoid valveswith separating diaphragm
Series K8DV
The increasing demand for
miniaturized solenoid valves with
separating diaphragm and the
experience acquired during the
realization of the Series K8 served
to create this new series of models
with total fluid separation.
In fact, the new Series K8DV was
born to meet all the demands to
shut off aggressive or heat sensitive
fluids requested by the latest
technologies. Thanks to a separating
diaphragm, the fluid is isolated
from all internal metal parts of the
solenoid valve and avoids heating,
even if minimum, generated
by the solenoid positioned above.
The material of the diaphragm,
available in FKM, EPDM or FFKM
and the body in PEEK, enable this
solenoid valve to be used in a very
wide range of applications in the
medical, analytical, chemical and
pharmaceutical, biotechnological
and environmental sector.
Available in a cartridge version or
suitable to be mounted on a subbase
and thanks to its reduced dimensions,
it satisfies all installation needs of
portable or laboratory devices.
5
Generaldata
TECHNICAL SPECIFICATIONS
Function 2/2 NC
Operation directly operated with separating diaphragm
Pneumatic connections cartridge for manifold or flanged for subbase
Nominal diameter 0.7 mm
Kv (l/min) 0.1
Operating pressure 0 ÷ 2 bar
Operating temperature 5 ÷ 50°C
Fluid Liquids / aggressive or inert gases
Response times ON ≤ 10 ms - OFF ≤ 15 ms
Installation any position
MATERIALS IN CONTACT WITH FLUID
Body PEEK
Seals FKM - EPDM - FFKM
ELECTRICAL SPECIFICATIONS
Voltage 24 V DC - 12 V DC - 6 V DC - 5 V DC - 3 V DC - other voltages upon request
Voltage tolerance ±10%
Absorption 0.6 W
Duty cycle ED 100%
Electrical connection 2 Pins 0.5 x 0.5 Interaxis 4 mm
Protection class IP00
Codingexample
K8DV SERIES
C TYPE OF BODY:C = cartridge version - 0 = flanged version
00 NUMBER OF POSITIONS:00 = valve without housing
5 NUMBER OF WAYS - FUNCTIONS:5 = 2-way NC
0 SEAL MATERIAL: 0 = FKM - 4 = EPDM - 5 = FFKM
5 NOMINAL DIAMETER: 5 = 0.7 mm
G BODY MATERIAL: G = PEEK
2 ELECTRICAL CONNECTION: 2 = interface pin size 4 mm
3 SOLENOID VOLTAGES: 4 = 3V DC (0.6 W) - 5 = 5V DC (0.6 W) - 1 = 6V DC (0.6 W) - 2 = 12V DC (0.6 W) - 3 = 24V DC (0.6 W)
K8DV C 00 - 5 0 5 - G 2 3
Dimensions
2
1
NEWS 2017 | CONTROL > SERIES K8DV
6
Directly operated solenoid valvesSeries K 2/2-way
> COMPACT DESIGN
> HIGH PERFORMANCE
> SUITABLE FOR APPLICATIONS IN MEDICAL EQUIPMENT AND ANALYTICAL INSTRUMENTS
> VERSIONS AVAILABLE FOR USE WITH OXYGEN
From the Series K, already included
in our catalogue, a new range
of models has been developed with
only the 2-way NC function
and new flow characteristics.
The range of the orifices available
has been enlarged with diameters
from 0.6 up to 1.4 mm.
To guarantee a perfect integration
with the already existing range,
the same electrical connection
characteristics and the same
footprint were maintained in order to
have the inlet and outlet ports in the
same position of the 3-way models.
This enables to use solenoid valves
with 2-way and 3-way with common
inlets or outlets on the same manifold,
optimizing the processings of the flow
channels to intercept.
All models also have versions that are
suitable to be used with oxygen.
The procedures applied for the cleaning
of components, of assembly and of
packaging, are performed according
to the ASTM G93 standards.
7
Generaldata
TECHNICAL SPECIFICATIONS
Function 2/2 NC Operation directly operated with poppet Pneumatic connections on subbase by means of screwsNominal diameter 0.6 - 1.0 - 1.4 mm Kv (l/min) Ø 0.6 = 0.18 / Ø 1.0 = 0.4 / Ø 1.4 = 0.45 Operating pressure Ø 0.6 = 0 ÷ 6 bar / Ø 1.0 = 0 ÷ 3 bar / Ø 1.4 = 0 ÷ 2 barOperating temperature 0 ÷ 50°C Fluid filtered air class 5.4.4 according to ISO 8573-1 (viscosity oil max. 32 cSt), inert gasesResponse times ON <10 msec - OFF <10 msec Manual operation with monostable buttonInstallation any position
MATERIALS IN CONTACT WITH FLUID
Body Technopolymer PBT Seals FKMInternal parts Stainless steel
ELECTRICAL SPECIFICATIONS
Voltage 24 V DC - 12 V DC - 6 V DC - other voltages upon requestVoltage tolerance ±10% Absorption 1 W Duty cycle ED 100%Electrical connection connector - wires L = 300 mmProtection class IP50
Coding example
K SERIES
0 TYPE OF BODY:0 = single base (only M5) or interface - 1 = manifold
00 NUMBER OF POSITIONS:00 = interface - 01 = single base (only M5) - 02 ÷ 99 = N° of positions on manifold
1 NUMBER OF WAYS - FUNCTIONS:0 = manifold or single base - 1 = 2/2-way NC - 2 = 2/2-way NC electric part turned by 180°
0 PORTS: 0 = interface - 2 = M5 side outlets
5 NOMINAL DIAMETER: 2 = 0.60 mm - 5 = 1.00 mm - 7 = 1.40 mm
K MATERIALS: K = PBT body, HNBR poppet seal - F = PBT body, FKM poppet seal
2ELECTRICAL CONNECTION: 1 = 90° conn. with protection and led B = in-line conn. with protection and led F = wires (300 mm) with protection and led2 = 90° conn. with protection C = in-line conn. with protection G = wires (300 mm) with protection3 = 90° connection D = in-line connection H = wires (300 mm)
3 SOLENOID VOLTAGES: 1 = 6 VDC - 2 = 12 VDC - 3 = 24 VDC
MOUNTING: = standard to be mounted on plastic interface - M = with screws for mounting on metal interfaces (upon request)
VERSION: = not to be used for oxygen - OX1 = for use with oxygen (non volatile residual less than 550 mg/m²)OX1 = for use with oxygen (non volatile residual less than 33 mg/m²)
K 0 00 - 1 0 5 - K 2 3
Dimensions
2
1
NEWS 2017 | CONTROL > SERIES K
8
Pneumatically and electropneumatically operated valves
Series 8
> HIGH FLOW
> VERSIONS AVAILABLE FOR USE WITH OXYGEN
The Series 8 enlarges the range
of models available with the cartridge
valve directly integrated in an
anodized aluminium body comprising
also the pilot solenoid valve.
The new bodies enable to have
pneumatically operated models with
external pilot or electropneumatically
operated models with both external
and internal piloting.
The internal pilot takes the pressure
needed to activate the cartridge
valve directly from the main pressure
line, avoiding further pneumatic
connections. In this case, to guarantee
a correct operation, a minimum
pressure of 3 bar must be present.
In case it is necessary to activate
the cartridge valve with a pressure
less that 3 bar in the main line, it is
necessary to use models with external
piloting, making sure to guarantee
a pressure between 3 and 6 bar.
For the Normally Open function,
a continuous pneumatic piloting
must be guaranteed.
Besides different types of electrical
connections, all models also have
versions that are suitable to be used
with oxygen. The procedures applied
for the cleaning of components,
of assembly and of packaging, are
performed according to the ASTM G93
standards.
9
TECHNICAL SPECIFICATIONS
Function 2/2 NC - 2/2 NO - 3/2 NC - 3/2 NO
Operation pneumatic
Pneumatic connections Size 1 = G1/8 - Size 2 = G1/4 - Size 3 = G3/8
Nominal diameter Size 1 = 5.0 mm - Size 2 = 6.6 mm - Size 3 = 9 mm
Kv (l/min) Size 1 = 6.5 - Size 2 = 12.5 - Size 3 = 23
Flow (6 bar ∆P 1 bar) Size 1 = 420 l/min - Size 2 = 800 l/min - Size 3 = 1480 l/min
Operating pressure 0 ÷ 6 bar
External pilot pressure 3 ÷ 6 bar
Operating temperature 0 ÷ 50°C
Fluid filtered air class 5.4.4 according to ISO 8573-1 (viscosity oil max. 32 cSt), inert gases
Response times ON <10 msec - OFF <10 msec
Installation any position
MATERIALS IN CONTACT WITH FLUID
Body Aluminium
Seals FKM
Internal parts Aluminium - Brass
Generaldata
pneumaticoperation
Generaldata
electropneumatic operation
TECHNICAL SPECIFICATIONS
Function 2/2 NC - 2/2 NO - 3/2 NC - 3/2 NO
Operation electropneumatic
Pneumatic connections Size 1 = G1/8 - Size 2 = G1/4 - Size 3 = G3/8
Nominal diameter Size 1 = 5.0 mm - Size 2 = 6.6 mm - Size 3 = 9 mm
Kv (l/min) Size 1 = 6.5 - Size 2 = 12.5 - Size 3 = 23
Flow (6 bar ∆P 1 bar) Size 1 = 420 l/min - Size 2 = 800 l/min - Size 3 = 1480 l/min
Operating pressure 3 ÷ 6 bar (0 ÷ 6 bar with external pilot)
External pilot pressure 3 ÷ 6 bar
Operating temperature 0 ÷ 50°C
Fluid filtered air class 5.4.4 according to ISO 8573-1 (viscosity oil max. 32 cSt), inert gases
Response times ON <10 msec - OFF <10 msec
Installation any position
MATERIALS IN CONTACT WITH FLUID
Body Aluminium
Seals FKM
Internal parts Aluminium - Brass
ELECTRICAL SPECIFICATIONS
Voltage 24 V DC – other voltages upon request
Voltage tolerance Size 1 = ±10% - Size 2 and 3 = -10% +15%
Absorption Size 1 = 1.3 W (acceleration) 0.25 W (maintenance) - Size 2 and 3 = 2 W
Duty cycle ED 100%
Electrical connection connector – wires L = 300 mm
Protection class Size 1 = IP50 - Size 2 and 3 = IP65 (with connector)
NEWS 2017 | CONTROL > SERIES 8
10
Dimensionselectropneumatic
operation
Coding example
8 SERIES
10 SIZE:10 = Size 1 - 20 = Size 2 - 30 = Size 3
C3 TYPE OF BODY:C3 = threaded body
4NUMBER OF WAYS - FUNCTIONS:1 = 2/2-WAY NC2 = 2/2-WAY NO4 = 3/2-WAY NC5 = 3/2-WAY NO
04PNEUMATIC CONNECTIONS:04 = G1/8” (Size 1)05 = G1/4” (Size 2)06 = G3/8” (Size 3)
F1NOMINAL DIAMETER:F1 = 5.0 mm (Size 1)G7 = 6.6 mm (Size 2)K1 = 9.0 mm (Size 3)
3 SEAL MATERIAL:3 = FKM
1 BODY MATERIAL:1 = aluminium
Y MANUAL OVERRIDE:N = not provided - Y = provided monostable
N MOUNTING ACCESSORIES:N = not provided
00OPTIONS:00 = no optionPP = pneumatic pilotPE = electropilot with external piloting
2C
ELECTRICAL CONNECTION:2C = connector type KN 90° + protection + led (Size 1)2F = connector type KN 90° in line + protection + led (Size 1)3A = DIN 43650 connector, form C, size 8 mm (Size 2 - 3)4A = DIN 43650 connector, form C, size 9.4 mm (Size 2 - 3)7A = L wires = 300 mm (Size 2 - 3)
C014
VOLTAGE - ABSORPTION:C012 = 12 V DC 1.3/0.25W (Size 1)C014 = 24 V DC 1.3/0.25W (Size 1)C020 = 12 V DC 2W (Size 2 - 3)C023 = 24 V DC 2W (Size 2 - 3)C025 = 48 V DC 2W (Size 2 - 3)
VERSION: = standardOX2 = for use with oxygen (non volatile residual less than 33 mg/m²)
8 10 C3 4 04 - F1 3 1 Y - N 00 2C C014
NEWS 2017 | CONTROL > SERIES 8
11
Dimensionselectropneumatic
operation
Mod. Function A B C D E F G H I L M N O P Q R S T U V Z Symbol
810C3404-F131Y-N002CC014 3/2 NC 31 71.5 16 11 10 20 16 34 33.8 52 17 8 23.9 47.5 3.2 6 G1/8 M3 6 - 10 EV54
810C3404-F131Y-NPE2CC014 3/2 NC 31 71.5 16 11 10 20 16 34 33.8 52 17 8 23.9 47.5 3.2 6 G1/8 M3 6 M5 10 EV56
820C3405-G731Y-NPE4AC023 3/2 NC 35 81 20 13 10 22 19.5 39.5 49 57 20 10 30 52.5 4.2 8 G1/4 M4 6.5 M5 15 EV56
820C3405-G731Y-N004AC023 3/2 NC 35 81 20 13 10 22 19.5 39.5 49 57 20 10 30 52.5 4.2 8 G1/4 M4 6.5 - 15 EV54
820C3505-G731Y-NPE4AC023 3/2 NO 35 81 20 13 10 22 19.5 39.5 49 57 20 10 30 52.5 4.2 8 G1/4 M4 6.5 M5 15 EV57
820C3505-G731Y-N004AC023 3/2 NO 35 81 20 13 10 22 19.5 39.5 49 57 20 10 30 52.5 4.2 8 G1/4 M4 6.5 - 15 EV58
830C3406-K131Y-NPE4AC023 3/2 NC 45 91 32 18 18 32 24 40 51.2 67 20.9 12 36 62.5 5.2 10 G3/8 M5 6 M5 15 EV56
830C3406-K131Y-N004AC023 3/2 NC 45 91 32 18 18 32 24 40 51.2 67 20.9 12 36 62.5 5.2 10 G3/8 M5 6 - 15 EV54
830C3506-K131Y-NPE4AC023 3/2 NO 45 91 32 18 18 32 24 40 51.2 67 20.9 12 36 62.5 5.2 10 G3/8 M5 6 M5 15 EV57
830C3506-K131Y-N004AC023 3/2 NO 45 91 32 18 18 32 24 40 51.2 67 20.9 12 36 62.5 5.2 10 G3/8 M5 6 - 15 EV58
Mod. Function A B C D E F G H I L M N O P Q R S T U V Z Symbol
810C3404-F131N-NPP 3/2 NC 31 - 16 11 10 20 16 34 - 52 17 8 23.9 47.5 3.2 6 G1/8 M3 6 - - YES1
820C3405-G731N-NPP 3/2 NC 35 - 20 13 10 22 19.5 39.5 - 57 20 10 30 52.5 4.2 8 G1/4 M4 6.5 M5 - YES1
830C3406-K131N-NPP 3/2 NC 45 - 32 18 18 32 24 40 - 67 20.9 12 36 62.5 5.2 10 G3/8 M5 6 M5 - YES1
Dimensionspneumaticoperation
NEWS 2017 | CONTROL > SERIES 8
12
Unidirectionalcartridge valve
Series VNR
> CARTRIDGE CONSTRUCTION PFOR USE IN A WIDE RANGE OF APPLICATIONS
> COMPACT DESIGN
> HIGH PERFORMANCE
> EASE OF INSTALLATION
> COMPATIBILITY BETWEEN MATERIALS USED AND SEVERAL GASEOUS FLUIDS
The cartridge construction of the
new Series VNR unidirectional valve
can be used in all those applications
and equipment where it is necessary
to include the single component in
personalized integrated pneumatic
circuits (manifolds) or collectors;
The compact design, in fact, allows
to be inserted and screwed in an
appropriate simple seat, in this way
simplifying installations. For its
construction, materials like
STAINLESS STEEL were selected
for the body and EPDM for the
tightenings in order to ensure full
compatibility with the most different
gaseous fluids.
13
Functioning This valve enables the passage of fluid from port 1 to port 2 and preventsthe flow in the opposite direction. The POPPET tightening elementguarantees two essential characteristics: to have a low minimum operating pressure and a high flow of gaseous fluid with minimum pressure losses.
Generaldata
Media Air, inert gases
Operating pressure up to 10 bar (145 psi)
Cracking pressure 0.05 bar (0.72 psi)
Operating pressure -5° ÷ +50°C
Materials in contact with the medium Stainless steel - EPDM
Orifice Ø 4 mm
Materials PARTS MATERIALS
1 Reduction Stainless steel
2 Body Stainless steel
3 Spring Stainless steel
4 Poppet EPDM
5 Cap Stainless steel
6 O-ring 10.5x1 EPDM
7 O-ring 6x1 EPDM
Dimensions
6
6
6
5
4
3
2
1
7
Coding example
VNR SERIES
C5 TYPE OF BODY: C5 = cartridge
00 PNEUMATIC CONNECTIONS: 00 = in manifold
E1 NOMINAL DIAMETER: E1 = 4.0 mm
4 SEAL MATERIAL: 4 = EPDM
3 BODY MATERIAL: 3 = stainless steel
OX2 VERSION: OX2 = for use with oxygen (non volatile residual less than 33 mg/m²)
VNR C5 00 - E1 4 3 - OX2
NEWS 2017 | CONTROL > SERIES VNR
M15x1
Ø12.4+0.1
0
0.8x45°
3.5
min
5
22.5
3.5
11 m
in
18 M
AX
Ø10 MAX
30°
30°
Ø13.2+0.1
0
SEAT
22.5
M15x1
ES.4
VALVE
14
2/2-way shut-off micro-valveSeries TC1-V
> COMPACT DESIGN AND REDUCED WEIGHT
> HIGH PERFORMANCE
> EASE OF INSTALLATION
> COMPATIBILITY BETWEEN MATERIALS USED AND SEVERAL GASEOUS FLUIDS
The new Series TC1-V shut-off
micro-valve combines the drive
mechanism and the interception
mechanism in one single device.
Its principle is based on the actuation
of a poppet by means of an operating
pressure applied above it.
The poppet, once actuated, moves
away from the tightening seal,
permitting the flow of the intercepted
fluid. By removing the actuation
pressure, the poppet repositions itself
on the tightening seal by means of a
spring positioned below that closes
the flow of the fluid.
The new Series TC1-V shut-off micro-
valve has been studied to be used in all
applications and equipment where it is
necessary to insert the component in
integrated and customized pneumatic
circuits (manifolds) or collectors.
The cartridge design and its compact
dimensions enable this shut-off
micro-valve to be inserted in a special
seat that results in an easy installation
and a reduction of assembly times.
For its realization the most suitable
materials for contact with fluids were
selected. The body in PPS and the
FKM tightening seals guarantee full
compatibility with a wide range of
gaseous fluids.
15
Construction compact with preformed diaphragm
Ports G1/8 o 1/8 NPTF (only with the aluminium body version)
Mounting in line or cartridge (any position)
Operating temperature -5°C ÷ +50°C
Operating pressure 0 ÷ 10 bar (with pilot pressure 0.6 ÷ 10 bar)
Nominal flow 240 Nl/min (6 bar ∆P 1 bar)
Media air, inert/medical gases and oxygen
Generaldata
Materials PARTS MATERIALS
1 Base body Anodized aluminium
2 Lower spring Stainless steel
3 Insert PPS
4 Poppet Stainless steel
5 Body PPS
6 Intermediate body Anodized aluminium
7 Valve guide Polyamide
8 Diaphragm FKM
9 Bell Polyamide
Seals FKM
Dimensions
6
5
4
3
2
1
7
8
9
Coding example
TC SERIES
1 SIZE
V VALVE
36 CONSTRUCTION:36 = pneumatic command
C PORTS:C = cartridge - 1/8 = G 1/8 - 1/8TF = 1/8 NPTF
V SEAL MATERIAL:V = FKM
OX2VERSION:OX1 = for use with oxygen (non volatile residual less than 550 mg/m²)OX2 = for use with oxygen (non volatile residual less than 33 mg/m²)
TC 1 - V 36 - C - V - OX2
NEWS 2017 | CONTROL > SERIES TC1-V
16
Series APDirectly operatedproportional valvesSize 16 and 22 mm
Series AP directly operated 2/2-way
proportional solenoid valves, NC,
with nominal diameters range from
0.8 to 2.4 mm, can be used where
an open loop flow control is required,
with gas mixtures, to control
free flows or blows, or emptying
chambers using vacuum.
Series AP proportional valves have
been manufactured to optimize and
reduce friction and stick-slip effects.
The output flow is proportional to the
control signal.
As they can work also in vacuum,
a minimum working pressure is not
required.
> PWM OR CURRENT OPERATION
> OPEN LOOP FLOW CONTROL
> ALSO SUITABLE FOR USE WITH VACUUM
> SEVERAL VERSIONS AVAILABLE:
> WITH BODY IN PVDF (SIZE 16 mm ONLY)
> WITH REAR FLANGED BODIES
> WITH LOWER FLANGED BODIES
> SUITABLE FOR USE WITH OXYGEN
> SEALS IN FKM AND NBR
17
Function 2/2 NC
Operation proportional directly operated
Ports M5 - G1/8 - with rear flanges - with lower flanges
Hysteresis Size 16 mm: 12% FS - Size 22 mm: 10% FS
Repeatibility Size 16 mm: 7% FS - Size 22 mm: 7% FS
Operating temperature 0 ÷ 60°C
Mediumfiltered compressed air, unlubricated, according to ISO 8573-1 class 3.4.3, inert gas. All the valves are suitable for use with oxygen.
Installation any position
Materialsbody = brass / PVDF (size 16 mm only) seals = NBR and FKM
GP7 GPH U711 U712
Nominal resistance 193 ohm 48 ohm 85 ohm 22 ohm
Rated current 125 mA 250 mA 271 mA 542 mA
Generaldata
NOTE: Having a counterpressure on the outlet connection of at least 25% of the inlet pressure ensures the good functioning of the valve and improves its performance. Example: with inlet Pressure = 1 bar on the outlet connection, a min. counterpressure of 250 mbar is recommended.
Coding example
AP SERIES
7BODY: 6 = size 16 mm7 = size 22 mm
2 NUMBER OF WAYS: 2 = 2-way
1 VALVE FUNCTION: 1 = NC
1PORTS: 0 = M5 (size 16 mm only) 4 = with rear flanges 1 = G1/8 (size 22 mm only) 5 = with lower flangesL = male hose adaptor (for body in PVDF only, size 16 mm)
LNOMINAL DIAMETER: D = 0.8 mm (for size 16 mm only) L = 1.6 mm F = 1 mm N = 2 mm (for size 22 mm only) H = 1.2 mm Q = 2.4 mm (for size 22 mm only)
RSEAL MATERIAL: R = NBRW = FKM
2BODY MATERIAL: 2 = OT3 = PVDF (for size 16 mm only)
UENCAPSULATING MATERIAL: G = PA (for size 16 mm only)U = PET (for size 22 mm only)
7SOLENOID DIMENSIONS: P = 16x26 DIN EN 175301-803-C (for size 16 mm only)7 = 22x22 DIN 43650 B (for size 22 mm only)
11SOLENOID VOLTAGE: H = 12 V DC 3 W (for size 16 mm only) 11 = 24 V DC 6.5 W (for size 22 mm only) 7 = 24 V DC 3 W (for size 16 mm only) 12 = 12 V DC 6.5 W (for size 22 mm only)
OX2VERSION: OX2 = version with ASTM G93-03 Certification Level B (FKM seals only) = non-certified NBR version
NEWS 2017 | CONTROL > SERIES AP
AP - 7 2 1 1 - L R 2 - U 7 11 OX2
18
Flow diagrams
Size 16 mm
Nozzle 0.8 mm Q = Flow (Nl/min)I = Current (A)FS = Full scale
Nozzle 1 mm Q = Flow (Nl/min)I = Current (A)FS = Full scale
Nozzle 1.2 mm Q = Flow (Nl/min)I = Current (A)FS = Full scale
Nozzle 1.6 mm Q = Flow (Nl/min)I = Current (A)FS = Full scale
NEWS 2017 | CONTROL > SERIES AP
19
Flow diagrams
Size 22 mm
Nozzle 2.4 mm Q = Flow (Nl/min)I = Current (A)FS = Full scale
Nozzle 1 mm Q = Flow (Nl/min)I = Current (A)FS = Full scale
Nozzle 1.2 mm Q = Flow (Nl/min)I = Current (A)FS = Full scale
Nozzle 1.6 mm Q = Flow (Nl/min)I = Current (A)FS = Full scale
Nozzle 2 mm Q = Flow (Nl/min)I = Current (A)FS = Full scale
NEWS 2017 | CONTROL > SERIES AP
20
RESPONSE TIMES calculated according to the maximum flow at each operating pressure. [Electromechanical response time: 10 ms]
Size ø Pin [bar] Load response time [ms] Exhaust response time [ms]
0% - 10% 0% - 90% 10% - 90% 100% - 90% 100% - 10% 90% - 10%
16 mm 0.8 mm 10 12 43 31 11 39 28
16 mm 1 mm 8 12 42 30 11 38 27
16 mm 1.2 mm 6 10 41 31 11 41 30
16 mm 1.6 mm 4 10 40 30 11 40 29
22 mm 1 mm 10 10 36 26 10 36 26
22 mm 1.2 mm 8 10 45 35 12 38 26
22 mm 1.6 mm 6 12 45 33 12 40 28
22 mm 2 mm 5 12 42 30 11 34 26
22 mm 2.4 mm 4 11 45 34 12 44 32
Proportionalvalves
Size 16 mmwith lower flanges
Maximum flow according to the
inlet pressure
NEWS 2017 | CONTROL > SERIES AP
Size 22 mm Q = Flow (Nl/min) P = Inlet pressure (bar)
Size 16 mm Q = Flow (Nl/min) P = Inlet pressure (bar)
Q = FlowD.C. = Duty cycle
Hysteresisand
response times
21
2 1
Mod. Connection 1 Connection 2 Function Orifice ø (mm) Kv (l/min) Max pressure (bar) Max flow (Nl/min)
AP-6210-DR2-GP* M5 M5 2/2 NC 0.8 0.3 10 43
AP-6210-FR2-GP* M5 M5 2/2 NC 1 0.45 8 53
AP-6210-HR2-GP* M5 M5 2/2 NC 1.2 0.57 6 53
AP-6210-LR2-GP* M5 M5 2/2 NC 1.6 0.78 4 52
AP-6210-DW2-GP*OX2 M5 M5 2/2 NC 0.8 0.3 10 43
AP-6210-FW2-GP*OX2 M5 M5 2/2 NC 1 0.45 8 53
AP-6210-HW2-GP*OX2 M5 M5 2/2 NC 1.2 0.57 6 53
AP-6210-LW2-GP*OX2 M5 M5 2/2 NC 1.6 0.78 4 52
Mod. Function Orifice ø (mm) Kv (l/min) Max pressure (bar) Max flow (Nl/min)
AP-6215-DR2-GP* 2/2 NC 0.8 0.3 10 43
AP-6215-FR2-GP* 2/2 NC 1 0.45 8 53
AP-6215-HR2-GP* 2/2 NC 1.2 0.57 6 53
AP-6215-LR2-GP* 2/2 NC 1.6 0.78 4 52
AP-6215-DW2-GP*OX2 2/2 NC 0.8 0.3 10 43
AP-6215-FW2-GP*OX2 2/2 NC 1 0.45 8 53
AP-6215-HW2-GP*OX2 2/2 NC 1.2 0.57 6 53
AP-6215-LW2-GP*OX2 2/2 NC 1.6 0.78 4 52
Proportionalvalves
Size 16 mm
Proportionalvalves
Size 16 mmwith lower flanges
2 1
* choose the desired voltage
* choose the desired voltage
For the use with vacuumconnect the line to connection 2.
For the use with vacuumconnect the line to connection 2.
NEWS 2017 | CONTROL > SERIES AP
22
* choose the desired voltage
* choose the desired voltage
Mod. Function Orifice ø (mm) Kv (l/min) Max pressure (bar) Max flow (Nl/min)
AP-6214-DR2-GP* 2/2 NC 0.8 0.3 10 43
AP-6214-FR2-GP* 2/2 NC 1 0.45 8 53
AP-6214-HR2-GP* 2/2 NC 1.2 0.57 6 53
AP-6214-LR2-GP* 2/2 NC 1.6 0.78 4 52
AP-6214-DW2-GP*OX2 2/2 NC 0.8 0.3 10 43
AP-6214-FW2-GP*OX2 2/2 NC 1 0.45 8 53
AP-6214-HW2-GP*OX2 2/2 NC 1.2 0.57 6 53
AP-6214-LW2-GP*OX2 2/2 NC 1.6 0.78 4 52
Proportionalvalves
Size 16 mmwith rear flanges
Proportionalvalves
Size 22 mm
Proportionalvalves
Size 16 mmbody in PVDF
2
1
Mod. Connection 1 Connection 2 Function Orifice ø (mm) Kv (l/min) Max pressure (bar) Max flow (Nl/min)
AP-7211-FR2-U7* G1/8 G1/8 2/2 NC 1 0.5 10 75
AP-7211-HR2-U7* G1/8 G1/8 2/2 NC 1.2 0.7 8 85
AP-7211-LR2-U7* G1/8 G1/8 2/2 NC 1.6 1.2 6 110
AP-7211-NR2-U7* G1/8 G1/8 2/2 NC 2 1.7 5 135
AP-7211-QR2-U7* G1/8 G1/8 2/2 NC 2.4 1.7 4 113
AP-7211-FW2-U7*OX2 G1/8 G1/8 2/2 NC 1 0.5 10 75
AP-7211-HW2-U7*OX2 G1/8 G1/8 2/2 NC 1.2 0.7 8 85
AP-7211-LW2-U7*OX2 G1/8 G1/8 2/2 NC 1.6 1.2 6 110
AP-7211-NW2-U7*OX2 G1/8 G1/8 2/2 NC 2 1.7 5 135
AP-7211-QW2-U7*OX2 G1/8 G1/8 2/2 NC 2.4 1.7 4 113
2 1 For the use with vacuumconnect the line to connection 2.
For the use with vacuumconnect the line to connection 2.
NEWS 2017 | CONTROL > SERIES AP
23
* choose the desired voltage
Mod. Function Orifice ø (mm) Kv (l/min) Max pressure (bar) Max flow (Nl/min)
AP-7215-FR2-U7* 2/2 NC 1 0.5 10 75
AP-7215-HR2-U7* 2/2 NC 1.2 0.7 8 85
AP-7215-LR2-U7* 2/2 NC 1.6 1.2 6 110
AP-7215-NR2-U7* 2/2 NC 2 1.7 5 135
AP-7215-QR2-U7* 2/2 NC 2.4 1.7 4 113
AP-7215-FW2-U7*OX2 2/2 NC 1 0.5 10 75
AP-7215-HW2-U7*OX2 2/2 NC 1.2 0.7 8 85
AP-7215-LW2-U7*OX2 2/2 NC 1.6 1.2 6 110
AP-7215-NW2-U7*OX2 2/2 NC 2 1.7 5 135
AP-7215-QW2-U7*OX2 2/2 NC 2.4 1.7 4 113
Proportionalvalves
Size 16 mmbody in PVDF
Proportionalvalves
Size 22 mmwith lower flanges
2 1
Mod. Connection 1 Connection 2 Function Orifice ø (mm) Kv (l/min) Max pressure (bar) Max flow (Nl/min)
AP-621L-DR3-GP* Ø6 ** Ø6 ** 2/2 NC 0.8 0.3 10 43
AP-621L-FR3-GP* Ø6 ** Ø6 ** 2/2 NC 1 0.45 8 53
AP-621L-HR3-GP* Ø6 ** Ø6 ** 2/2 NC 1.2 0.57 6 53
AP-621L-LR3-GP* Ø6 ** Ø6 ** 2/2 NC 1.6 0.78 4 52
AP-621L-DW3-U7*OX2 Ø6 ** Ø6 ** 2/2 NC 0.8 0.3 10 43
AP-621L-FW3-U7*OX2 Ø6 ** Ø6 ** 2/2 NC 1 0.45 8 53
AP-621L-HW3-U7*OX2 Ø6 ** Ø6 ** 2/2 NC 1.2 0.57 6 53
AP-621L-LW3-U7*OX2 Ø6 ** Ø6 ** 2/2 NC 1.6 0.78 4 52
* choose the desired voltage ** pneumatic connection with tube and clamps
2 1
For the use with vacuumconnect the line to connection 2.
For the use with vacuumconnect the line to connection 2.
NEWS 2017 | CONTROL > SERIES AP
24
> HIGH FLOW
> GREAT PRECISION
> LOW HYSTERESIS
> HIGH WORKING DYNAMICS
> CARTRIDGE BODY FOR INSTALLATION IN REDUCED SPACE
Series CP directly operated
proportional valves can be used
where an open loop flow control is
required, with gas mixtures or to
control flows.
Series CP valves have been designed
to optimize dimensions and reduce
friction and stick-slip effects.
The output flow is proportional
to the control signal.
As they can work also in vacuum,
a minimum working pressure is not
required.
Their cartridge design makes them
particularly compact, thus they can be
mounted directly near the workstation.
Series CPDirectly operatedproportional valvesSize 16 and 20 mm
25
Generaldata
Size 16 mm
Generaldata
Size 20 mm
TECHNICAL FEATURES
Function 2/2 NC Operation proportional directly operatedPneumatic connections cartridgeNominal diameters 1 - 1.5 - 2 mmFree flow capacity 70 - 80 - 90 Nl/minOperating pressure 2.8 - 2 barMax overpressure 16 barLinearity 3% FSHysteresis 10% FSRepeatibility 5% FSOperating temperature 10°C ÷ 50°C
Media filtered compressed air, unlubricated, according to ISO 8573-1 class 3.4.3, inert gas. Also suitable for use with oxygen.
Installation any position
MATERIALS IN CONTACT WITH THE MEDIUM
Body brass, stainless steel, PPSSeals FKM
ELECTRICAL FEATURES
Operation PWM > 1000 Hz or current controlOperation voltage 6 - 12 - 24 V DCMax power consumption 2 WNominal resistance 11.8 - 37.6 - 184.7 OhmRated current 410 - 238 - 103 mADuty cycle 100%Electrical connection cable 300 mm AWG 24Protection class IP00 / IP40Average lifecycles 50000000Versions available on demand base with 1/8 - 1/4 ports
TECHNICAL FEATURES
Function 2/2 NC Operation proportional directly operatedPneumatic connections cartridgeNominal diameters 3 - 3.5 mmFree flow capacity 145 - 165 Nl/minOperating pressure 2.8 - 2 barMax overpressure 16 barLinearity 5% FSHysteresis 15% FSRepeatibility 5% FSOperating temperature 10°C ÷ 50°C
Media filtered compressed air, unlubricated, according to ISO 8573-1 class 3.4.3, inert gas. Also suitable for use with oxygen.
Installation any position
MATERIALS IN CONTACT WITH THE MEDIUM
Body brass, stainless steel, PPSSeals FKM
ELECTRICAL FEATURES
Operation PWM > 500 Hz or current controlOperation voltage 6 - 12 - 24 V DCMax power consumption 3.7 - 3 WNominal resistance 6.4 - 25.1 - 102.1 OhmRated current 615 - 313 - 154 mADuty cycle 100%Electrical connection cable 300 mm AWG 24Protection class IP00 / IP40Average lifecycles 50000000Versions available on demand base with 1/8 - 1/4 ports
NEWS 2017 | CONTROL > SERIES CP
26
Coding example
CP SERIES
CPORTS: C = cartridge S = subbase
6BODY: 6 = size 16 mm 7 = size 20 mm
2 NUMBER OF WAYS: 2 = 2-WAY
1 FUNCTION: 1 = NC
G
ORIFICE DIAMETRES: F = 1 mm (size 16 mm only) G = 1.5 mm (size 16 mm only) N = 2 mm (size 16 mm only) M = 3 mm (size 20 mm only) P = 3.5 mm (size 20 mm only)
W SEAL MATERIAL: W = FKM
2 BODY MATERIAL: 2 = brass
0 OVERMOULDING MATERIAL OF COIL: 0 = cartridge
PCOIL DIMENSIONS: P = ø 16 7 = ø 20
3
VOLTAGE: 1 = 6 V DC 3.1 W (size 16 mm only) 2 = 12 V DC 4.3 W (size 20 mm only) 3 = 24 V DC 3.1 W (size 16 mm only) 4 = 24 V DC 4.3 W (size 20 mm only) 5 = 12 V DC 3.1 W (size 16 mm only)
6 = 6 V DC 4.3 W (size 20 mm only) 7 = 6 V 4.8 W (only Ø 3.5, size 20 mm) 8 = 12 V 4.8 W (only Ø 3.5, size 20 mm)9 = 24 V 4.8 W (only Ø 3.5, size 20 mm)
CP - C 6 2 1 - G W 2 - 0 P 3
NEWS 2017 | CONTROL > SERIES CP
27
Flowdiagrams
Size 16 mm
Nominal diameter 3.5 mm Q = Flow (Nl/min) I = Current (A) P1 = Pressure in load (bar) P2 = 0 [free flow pressure] (bar) FS = Full scale
Nominal diameter 1 mm Q = Flow (Nl/min) I = Current (A) P1 = Pressure in load (bar) P2 = 0 [free flow pressure] (bar) FS = Full scale
Nominal diameter 1.5 mm Q = Flow (Nl/min) I = Current (A) P1 = Pressure in load (bar) P2 = 0 [free flow pressure] (bar) FS = Full scale
Nominal diameter 3 mm Q = Flow (Nl/min) I = Current (A) P1 = Pressure in load (bar) P2 = 0 [free flow pressure] (bar) FS = Full scale
Nominal diameter 2 mm Q = Flow (Nl/min) I = Current (A) P1 = Pressure in load (bar) P2 = 0 [free flow pressure] (bar) FS = Full scale
NEWS 2017 | CONTROL > SERIES CP
Flowdiagrams
Size 20 mm
28
Maximumpressure
according to theinlet pressure
RESPONSE TIMES calculated according to the maximum flow at each operating pressure. [Electromechanical response time: 10 ms]
Size ø Pin [bar] Load response time [ms] Exhaust response time [ms]
0% - 10% 0% - 90% 10% - 90% 100% - 90% 100% - 10% 90% - 10%
16 mm 1 mm 8 12 42 30 9 33 24
16 mm 1.5 mm 5 12 39 27 9 33 24
16 mm 2 mm 3 11 39 28 9 33 26
20 mm 3 mm 2.8 13 29 16 14 28.5 14.5
20 mm 3.5 mm 2 15 31 16 12.5 27.5 15
NEWS 2017 | CONTROL > SERIES CP
Size 20 mm Q = Flow (Nl/min) P = Inlet pressure (bar)
Size 16 mm Q = Flow (Nl/min) P = Inlet pressure (bar)
Isteresi e tempi di risposta
Q = FlowD.C. = Duty cycle
29
Mod. Orifices Ø (mm) Max operating pressure (bar) Max flow (Nl/min) Max flow Kv (l/min) Operation voltage (V DC) Max current (mA)
CP-C621-FW2-0P1 1 8 70 0.55 6 410
CP-C621-GW2-0P1 1.5 5 80 0.88 6 410
CP-C621-NW2-0P1 2 3 90 1.42 6 410
CP-C621-FW2-0P3 1 8 70 0.55 24 103
CP-C621-GW2-0P3 1.5 5 80 0.88 24 103
CP-C621-NW2-0P3 2 3 90 1.42 24 103
CP-C621-FW2-0P5 1 8 70 0.55 11 238
CP-C621-GW2-0P5 1.5 5 80 0.88 11 238
CP-C621-NW2-0P5 2 3 90 1.42 11 238
Solenoid valvesSize 16 mm
Solenoid valves Size 20 mm
Mod. Orifices Ø (mm) Max operating pressure (bar) Max flow (Nl/min) Max flow Kv (l/min) Operation voltage (V DC) Max current (mA)
CP-C721-MW2-072 3 2.8 150 2.8 6 615
CP-C721-MW2-074 3 2.8 150 2.8 12 313
CP-C721-MW2-076 3 2.8 150 2.8 24 154
CP-C721-PW2-072 3.5 2 130 3 6 615
CP-C721-PW2-074 3.5 2 130 3 12 313
CP-C721-PW2-076 3.5 2 130 3 24 154
NEWS 2017 | CONTROL > SERIES CP
30
Cartridge pressureregulator
Series TC1-R
> PORTS: CARTRIDGE CONSTRUCTION, G1/8 AND 1/8 NPTF
> FOR APPLICATIONS WITH OXYGEN, WITHOUT RELIEVING
> COMPACT DESIGN
> HIGH PERFORMANCE
> EASE OF INSTALLATION
> COMPATIBILITY BETWEEN MATERIALS USED AND SEVERAL GASEOUS FLUIDS
The new Series TC pressure
regulator has been designed to be
used in all those applications and
equipment where it is necessary
to include the single component
in customized integrated pneumatic
circuits (manifolds) or collectors.
The cartridge construction
and the compact design allow
the regulator to be inserted
and screwed in an proper seat,
thus simplifying installations
and reducing assembly times.
For the creation of this new regulator,
materials have been analized and
chosen on the basis of their suitability
with the contact medium.
The body in PPS and the seals in
FKM thus ensure full compatibility
with a wide range of gaseous fluids.
31
Generaldata
Construction modular, compact wiht pre-formed diaphragm
Ports G1/8 (for version with aluminium body only)
Mounting in-line or cartridge (in any position)
Operating temperature -5°C ÷ +50°C
Inlet pressure 0 ÷ 10 bar
Outlet pressure 0 ÷ 0.5 bar; 0 ÷ 2 bar; 0 ÷ 3 bar; 0 ÷ 4 bar
Secondary pressure relieving No Relieving
Media oxygen, air and inert and medical gases
Repeatability ±0.2% FS
Materials
7
6
1
2
5
8
4
3
Coding example
TC SERIES
1 SIZE
R REGULATOR
3 WORKING PRESSURE:1 = 0 ÷ 0.5 bar 2 = 0 ÷ 2 bar 3 = 0 ÷ 3 bar 4 = 0 ÷ 4 bar
1 TYPE OF CONSTRUCTION: 1 = without relieving
C PORTS: C = cartridge 1/8 = G1/8 1/8TF = 1/8NPTF
V SEAL MATERIAL: V = FKM
OX2VERSION: OX1 = for use with oxygen (non volatile residual less than 550 mg/m²)OX2 = for use with oxygen (non volatile residual less than 33 mg/m²)
TC 1 - R 3 1 - C - V - OX2
PARTS MATERIALS
1 Base body Anodized aluminium
2 Lower spring Stainless steel
3 Insert PPS
4 Poppet Stainless steel
5 Body PPS
6 Valve guide PPS
7 Diaphragm FKM
8 Bell Polyamide
Seals FKM
NEWS 2017 | TREATMENT > SERIES TC1-R
32
Dimensionsof the seat
for cartridgeregulator
Dimensionsof the
regulator
with base bodycartridge
NEWS 2017 | TREATMENT > SERIES TC1-R
33
Flowdiagrams
NEWS 2017 | TREATMENT > SERIES TC1-R
Working pressure: 0 ÷ 2 bar
Pr = Regulated pressureQ = FlowPa = Inlet pressure
Working pressure: 0 ÷ 4 bar
Pr = Regulated pressureQ = FlowPa = Inlet pressure
Working pressure: 0 ÷ 0.5 bar
Pr = Regulated pressureQ = FlowPa = Inlet pressure
Working pressure: 0 ÷ 3 bar
Pr = Regulated pressureQ = FlowPa = Inlet pressure
34
present, face to face, able to look into
people’s eyes and speak their language.
This is why Camozzi now has an
international network, based in Italy,
but present on every continent.
To understand markets and the small
but important differences between
them, a company cannot only rely on
the essential digital tools we all use
every day, but it needs to be locally
PRESENCE ON EVERY CONTINENT
23 SUBSIDIARIES
55 EXCLUSIVE DISTRIBUTORS
6 PRODUCTION FACILITIES
OVER 1200 EMPLOYEES
SUBSIDIARIES AND PRODUCTION FACILITIES
COUNTRYWITH EXCLUSIVE DISTRIBUTORS
ITALY HEADQUARTERS CAMOZZI SPA
The Camozziworldwide networkTo respond and act quickly
C_Fluid. Your fluid solutions.
MIX
CO
MU
NIC
AZ
ION
E -
MI
93-1
500-
0GB
027
11/
2016
www.camozzi.comA Camozzi Group Company
Never Ending Innovation
C_Fluid Control Main contacts
[email protected] further information about our products and conditions of sale, contact Camozzi C_Fluid Control Division at:
Camozzi spaSocietà UnipersonaleVia Eritrea, 20/I25126 Brescia - ItalyTel. +39 030 37921 Fax +39 030 2400430
Technical assistanceCatalogue product inquiries and requests for support:Tel. +39 030 [email protected] product inquiries:Tel. +39 030 [email protected]
Worldwide sales network
Camozzi Subsidiaries and Exclusive DistributorsTo check our sales network, visit the Camozzi website atContacts / Camozzi Worldwide