20
INSTRUMENT CATALOGUE CAT-2006-05 EXPANDING PROVEN CONCEPTS

Newer Instrument Catalogue A4 - Southern Implants ... · 08 I Southern Implants I Instrument Catalogue I-WI-C-S Also available in Short (S) Use with AWB type Abutments Use with EB

Embed Size (px)

Citation preview

INSTRUMENT CATALOGUECAT-2006-05

EXPANDING PROVEN CONCEPTS

Design & Layout by Ruan Pienaar

Dear Customers and Colleagues

Graham BlackbeardManaging DirectorSouthern Implants

Today, Dental Implants have become an indispensable part of Dental treatment options. With the globalization of medical infrastructures and higher standards of living, implant applications have rapidly become common.

Southern Implants has been a manufacturer and distributor of Dental Implants since 1987. Today, the Southern group is recognized as a leading bio-medical engineering entity, with major intellectual property and capabilities in implantable devices, arthroplasties, tissue regeneration, stem cells and cryoscience. The top-end professional users, who want more choices, have driven the product range expansion to enormous and exciting heights. Striving for excellence and meeting customer needs has lead to our wide product range characterized by numerous unique and innovative products which include:

- 3 interfaces: External hex, Internal morse taper/octagon, and Tri-nex.- Many products optimized for primary stability and suited for immediate loading.- The only angled-top tapered screw-form 12° and 24° Co-Axis implant.- Implant lengths from 6mm to 20mm and diameters from 2.90mm to 10mm.- A surface which continues to out-perform that which it is trialed against.- Color-coded components for easy part recognition.- 55° Zygomatic implant, optimized for load distribution.- Compatibility with major brands, giving the patient more options.- The MAX, wide diameter implant for molar teeth replacement.

Striving for excellence is synonymous with the search to improve. At Southern the development starts with computer simulation and Finite Element Modeling. This is followed by extensive laboratory trials and testing. Finally, clinical research has taken on a new dimension in our overall strategy where our preference is for independent RCTs.

Our sincere thanks to all specialists, dentists and technicians who give continual feedback, suggestions and input. The products here are our interpretation of your needs.

Yours sincerely

Southern Implants was established in 1987 as a manufacturer and distributor of dental implants. At this time the science on a worldwide basis was still in it's infancy. Southern implants has been a pioneer in this field for the last 21 years and has contributed extensively to enhancements with respects to the osseointegration of implant devices, surgical techniques, patient education and options of treatment.

The company is focused on the top-end specialist sector of the implant market. The product range is constantly being expanded to incorporate the newest technologies and trends. Where many of our competitors are rationalizing their product range, Southern is offering more choices.

The implants are made from ASTM-F67-95 Grade 4 pure titanium, with a tensile strength of 550 MPa. The surface is enhanced with abrasion and chemical conditioning. The surface has been proven by way of extensive animal and clinical trials and has been in use for more than 15 years.

Southern Implants is not only the leading implant company in Southern Africa, but is a significant role player in the USA, the UK, Europe and Australasia. Manufacturing plants are situated in Irene, South Africa and Irvine, California. Each Plant produces 60 000 implants per annum.

Why Southern Implants?

Introduction and Welcoming Letter

Blade DriversHex 0.9mm Instruments

Hex 1.22mm InstrumentsHex 1.27mm Instruments

Hex 1.58mm InstrumentsDBN Hex 2.5mm InstrumentsTORX no. 6 Instruments

Uni Grip InstrumentsSquare / Quad Instruments

AbutmentsOAB InstrumentsIT Placement Tools

Internal Drive - External Hex InstrumentsTri-nex Placement Tools

OsteotomesLaboratory InstrumentsAdditional Instruments

WrenchesAdditional Surgical Instruments

Bone MillsDirection IndicatorsScrew Removers

Externally Hexed Instrument TrayGeneral Prosthetic Tray

Tri-nex Instrument TrayIT Instrument Tray

MAX Instrument TraySurgical Drill Tray

Upright Externally Hexed TrayUpright Tri-Nex Tray

Upright IT Surgical TrayZygomatic Instrument Tray

Cleaning & Sterilizing Procedures

CertificatesComplimentary Manuals & InstructionsLabeling Symbols

Contact Details (Local and International)

......................................................................................................................................

......................................................................................................................................................

....................................................................................................................................................

.....................................................................................................................................................

.................................................................................................................................................

...........................................................................................................................................................

......................................................................................................................................................

........................................................................................................................................................

..........................................................................................................................................

.................................................................................................................................................................

.......................................................................................................................................................

.............................................................................................................................................................

................................................................................................................................................................

............................................................................................................................................................

.................................................................................................................................................

......................................................................................................................................

................................................................................................................................................................

............................................................................................................................

ContentInside Front Cover

Page 02

Page 03

Page 04

Page 05

Page 06

Page 07

Page 08

Page 09

Page 10

Page 11

Page 12

Page 13

Page 14

Page 15

Page 16

InsideBack Cover

Back Cover

www.southernimplants.com

I-BD-S I-BD-M I-BD-L I-HBDS I-HBDM I-HBDL I-WI-BS I-WI-BM I-WI-BL

I-BD-LH

Handheld Handpiece Bit Wrench Bit

Short

Medium

Long

Short

Medium

Long

Short

Medium

Long

Use with:

Warning:

Wrench Blade

Suitable for tightening small M1.4 prosthetic screw of Swedish origin

I-WI-BSN I-WI-BLN

Ensure that the blade is correctly fitted in the slot. If the tool is put into the slot at an angle, excessive force is put on small areas of the tool as only a small area of the tool is actually driving the screw, and hence breakage is more likely.

All slotted screws, excluding M1.4 Screw of Swedish origin (see Wrench Blades to the right).

I-CS-HD I-KEY-09I-CS-HDL I-HHD-09 I-WI-09

Handheld Handpiece Bit Wrench Bit

Use with: Coverscrews for the Externally Hexed range.

Handheld Long Handle

I-CS-LH

Handheld Long Handle

02 Southern Implants Instrument CatalogueI I

I-HD-S I-HD-M I-HD-L I-HHD-22S I-HHD-22M I-HHD-22L I-WI-22S I-WI-22M I-WI-22L

Handheld Handpiece Bit Wrench Bit

Short

Medium

Long

Short

Medium

Long

Short

Medium

Long

Use with: Externally Hexed Range: One-part Healing Abutments, Two-part Healing Abutments, Impression Copings, Ball Abutments, Hex Screws and Fixture Mounts.

I-HD-27-M I-KEY-27I-HD-27-L I-HHD-27 I-WI-27

Handheld Handpiece Bit Wrench Bit

Use with: American Hexed Screws. Dentsply, Steri-Oss, Calcitek.

I-HDT-M

Tapered

I-KEY-22

Medium

Long

I-HD-LH

Handheld Long Handle

03

I-KEY-58 I-HHD-58 I-WI-58

Handheld Handpiece Bit Wrench Bit

I-SCS-S I-SCS-M I-SCS-L I-HSCS-S I-WI-SCS-S

Handheld Handpiece Bit Wrench Bit

I-DBN I-HDBN-S I-WI-DBN-S

Handheld Handpiece Bit Wrench Bit

Short

Short

I-HDBN I-WI-DBN

I-HSCS-M I-HSCS-L I-WI-SCS-M I-WI-SCS-L

Use with: Sprint Implant Range

IT Range Implants

Short

Medium

Long

Short

Medium

Long

Use with: LIC Implants. ILBB, ILSS, ILS and ILT.

Use with:

Warning: The short SCS instruments can not be used with the octagon abutments due to the short shank.

04 Southern Implants Instrument CatalogueI I

Use with: Quad / Square type screws.

I-UGI-S I-UGI-LI-UGI-M I-HUG-S I-WI-UG-S

Handheld Handpiece Bit Wrench Bit

Use with: These instruments are used with Tri-nex Coverscrews, Healing Abutments, Overdenture Ball Abutments and Unigrip prosthetic screws

I-HUG-M I-HUG-L I-WI-UG-M I-WI-UG-L

Short

Medium

Long

Short

Medium

Long

Short

Medium

Long

I-QDI-S I-QDI-M I-QDI-L I-HQD-S I-HQD-M I-HQD-L I-WI-QS I-WI-QM I-WI-QL

Handheld Handpiece Bit Wrench Bit

Short

Medium

Long

Short

Medium

Long

Short

Medium

Long

I-UD-LH

Handheld Long Handle

I-QD-LH

Handheld Long Handle

05

I-AD I-HAD I-WI-A

Handheld Handpiece Bit Wrench Bit

I-HITS-S I-WI-ITS-S

Peek Bit (Spare) Handpiece Bit Wrench Bit

I-OAB I-WI-OAB

Handheld Handpiece Bit Wrench Bit

I-HITS I-WI-ITS

Use with: OAB Abutments and Overdenture Abutments

Use with: IT Range Implants

Use with: Standard Abutments, Conical Abutments and Compact Conical Abutments.

I-AD-LH

Handheld Long Handle

I-OAB-H I-WI-C-S

Short Short

SlotSlot

Hex

Use with IT Placement Tools

Hex

06 Southern Implants Instrument CatalogueI I

I-PBIT-2

Peek Bit (Spare)

Use with:

Use with Internal Drive Tools

I-PBIT-H

Tri-nex Implant Range.

I-HID-S I-WIID-S

Handpiece Bit Wrench Bit

Use with: Internal Drive Implants.

I-HID-M I-HID-L I-WIID-L

Short

Long

Short

Medium

Long

Handpiece Bit

Converters

I-HLH-35M I-HLH-35S I-HLH-43M I-HLH-43S I-HLH-60M I-HLH-60S

I-WIL-35S I-WIL-35M I-WIL-43S I-WIL-43M I-WIL-50S I-WIL-50M

Wrench Bit

I-WI-C-S

I-PBIT-L18

Use with Ø3.5 Placement Tools

I-HLH-50M I-HLH-50S

07

Peek Bits (Spares)

I-PBIT-L2

I-L43-12d I-L50-12d

Use with Co-Axis Tri-nex

Use with Ø4.3, 5.0 & 6 0 Placement ToolsØ Ø .

Used to convert the Handpiece Bits to be used

with a wrench.

Lapping Tool Reamers

2m

m P

oin

ted

2m

m C

upped

Ste

p-U

p1

3m

m P

oin

ted

3m

m C

upped

Ste

p-U

p2

4m

m P

oin

ted

4m

m C

upped

Futu

re S

ite D

eve

lopm

ent

5m

m P

oin

ted

SO

UTH

ER

N FS

D 6 m

m

SO

UTH

ER

N I-O

ST-5P

5 mm

SO

UTH

ER

N I-O

ST-4C

4 mm

SO

UTH

ER

N I-O

ST-4P

4 mm

SO

UTH

ER

N I-O

ST-S

U2 S

TEP

-UP

2

SO

UTH

ER

N I-O

ST-3C

3 mm

SO

UTH

ER

N I-O

ST-3P

3 mm

SO

UTH

ER

N I-O

ST-S

U1 S

TEP

-UP

1

SO

UTH

ER

N I-O

ST-2P

2 mm

SO

UTH

ER

N I-O

ST-2C

2 mm

I-H

AM

ME

R

Hammer Osteotomes

Use with: Maxillary implant site preparation and ridge expansion.

I-OST-2P

I-LT6

I-1.4H

I-OST-2C I-OST-SU1 I-OST-3P I-OST-3C I-OST-SU2 I-OST-4P I-OST-4C I-OST-5P I-FSDI-HAMMER

Ø2.4

LT18-2.4

Ø2.8

LT18-2.8

Ø2.6

LT18-2.6

Polishing Caps

Hand piece to Wrench Insert Converter Driver for ITS Solid Abutment Hand Tool for Angled Abutment

I-WI-SA

Use with AB type Abutments

Use with 3 series screws

Use with IB Implants

PPC-AB-1 PPC-AWB-1

PPC-BA-1/S

PPC-BBB-1/S

PPC-EB-1 PPC-EBA-1

PPC-IB-1/S

PPC-IBN-1/S

PPC-MC-1 PPC-MCW-1

PPC-35/S

PPC-43/S

PPC-50/S

Use with BA Implants

Use with BBB Implants

Use with IBN Implants

Use with Ø3.5 Tri-nex Implants

Use with Ø4.3 Tri-nex Implants

Use with Ø5.0 Tri-nex Implants

08 Southern Implants Instrument CatalogueI I

I-WI-C-S

Also available in Short (S)

Use with AWB type Abutments

Use with EB type Abutments

Use with EBA type Abutments

Use with AMC type Abutments

Use with AMCW type Abutments

PPC-60/S Use with Ø6.0 Tri-nex Implants

PPC-ITS-S Use with Ø6.0 Tri-nex Implants

PPC-ITS6-S Use with Ø6.0 Tri-nex Implants

Use with Tri-Nex screws

Use with 2 series screws & Tri-Nex Passive

Screws

Wrenches

Use with: Wrench bits.

N/C

M

10

20

32

I-TW I-TW-45I-RATCHET-2

Additional Surgical Instruments

Implant Inserter Can be used for manual insertion

of implants.

Abutment Clamp Used for handling

Abutments. Stainless Steel.

Needle for cleaning taps.

Titanium.

Retractor. Anodized

Aluminium.

I-CLAMP I-NEEDLE I-NIC

I-DE

I-IMP-INS-1

Thread Cutters

I-M1.8I-M1.4

Trephine Drills

D-TRE4 D-TRE5 D-TRE7D-TRE-3

Inte

rna

l ø

4.1

mm

Inte

rna

l ø

5.1

mm

Inte

rna

l ø

7.0

mm

Inte

rna

l ø

3.6

mm

I-TC1 I-TC5 I-TC6

Ø4 Ø5 Ø6

Tissue Cutters

Connector toHandpiece

Stainless Steel.

I-CON-X

Flat SpannerTo hold Fixture

Mount.

I-SP-X

Counter Torque Tool.

I-CT-1

Fixture Mount Holder

I-FM-H

Fixture Mount Extention

I-FME-XS/L

I-FORCEPS

I-M2

Please note that these instrument are not to scale or to the correct size relation to each other. Only for illustration purposes.

09

Drill Extensions

I-DE-MN

Direction Indicators

Bone Mills and Protector Caps

Screw Removers

I-BM-CAP orI-BM-CAP2 (two-part) I-BAM-CAP I-BBBM-CAP

I-BM-67 orI-BM-77

I-BAM-62 I-BAM-77

or

I-BBBM-77

I-DI12d-4T-10 I-DI12d-4T-13 I-DI12d-4T-15 I-DI12d-5T-10 I-DI12d-5T-13 I-DI12d-5T-15 I-DI12d-6T-10 I-DI12d-6T-13 I-DI12d-6T-15

I-DI-12d I-DI-4T-10 I-DI-4T-13 I-DI-4T-15 I-DI-5T-10 I-DI-5T-13 I-DI-5T-15 I-DI-6T-10 I-DI-6T-13 I-DI-6T-15I-DI I-DIL I-DI-24d

10 Southern Implants Instrument CatalogueI I

Information available on request

I-HEX-1

I-PROS-B

11

These trays fit into the I-CASSETTE-2 and are autoclavable. Please see sterilizing and cleaning instructions on page 16.

I -DE

I -CON X

I -HHD-22M

I -CON

I -CS-HD

I -CS-HDL

I -HD-M

I -SP

X

I -RATCHET / I -TW 45

I -DG 20

I -KE

Y 2

2

I -FM

E X

I-DIL

I- DI

I- DI

I -DI1

2D

I -DI1

2D

I -DI2

4D

I -DI2

4D

I-WI-DBN

7 10 11.5 13 15 18

I-CS-BD

I-R

AT

CH

ET

/ I-T

W-4

5

I-FM-H

I-BD-M

I-HD-M

I-CS-HD

I-UGI-M

I-UGI-L

I-HBD-M

I-HBD-L

I-HHD-22M

I-HHD-09

I-HUG-M

I-HUG-L

I-WI-BM

I-WI-BL

I-WI-22M

I-WI-09

I-WI-UGM

I-WI-UGL

Handheld Handpiece Wrench Inserts

Trays and instruments are sold separately.

I-DE

I-SCS-S

27

D-RB

D-20T-M15

D-40TPI-06

D-29T-M15

D-35T-M15

D-43T-M15

I-SCS-L

I-TW-45

I-WI-SA

I-FM-H

D-40TPI-08

D-40TPI-10

D-40TPI-12

D-40TPI-14

I-HSCS-S

I-HSCS-L

D-50TPI-06

D-50TPI-08

D-50TPI-10

D-50TPI-12

D-50TPI-14

I-HITS-S

I-WI-ITS-S

I-WI-ITS

I-HITS

I-WI-SCS-S

I-WI-SCS-L

I-TRI-NEX

I-IT

12 Southern Implants Instrument CatalogueI I

These trays fit into the I-CASSETTE-2 and are autoclavable. Please see sterilizing and cleaning instructions on page 16.

Trays and instruments are sold separately.

Ø3.5X16

I-HLH-35S

I-HLH-35M

I-HLH-43S I-HLH-50S

I-HLH-43M I-HLH-50M

I-RATCHET-2 / I-TW-45

Ø3.5X10

Ø3.5X13

Ø4.3X10 Ø5.0X10

Ø4.3X13 Ø5.0X13

Ø4.3X16 Ø5.0X16

I-UGI-L

D-RB-M

D-30T-M

D-20T-M

I-DE

I-UGI-S

I-HUG

I-AD I-WI-A

I-WI-C-SI-L43-12d I-L50-12d

I-HLH-60S

I-HLH-60M

Ø6.0X10

Ø6.0X13

Ø6.0X16

These trays fit into the I-CASSETTE-2 and are autoclavable. Please see sterilizing and cleaning instructions on page 16.

Trays and instruments are sold separately.

D-12T

D-RB-MSD-40TP-8.5 D-50TP-8.5 D-60TP-8.5

D-40TP-10 D-50TP-10 D-60TP-10

D-40TP-11.5 D-50TP-11.5 D-60TP-11.5

D-40TP-13 D-50TP-13 D-60TP-13

D-40TP-15 D-50TP-15 D-60TP-15

D-40TP-18 D-50TP-18 D-60TP-18

D-20T

D-30T

D-35T

D-40T

D-43T

D-46T

D-50T

D-CB-F

D-CSS-M D-CSS-5

D-53T

D-56T

D-CS-IBN / IMS

D-CB-40M D-CB-50M

MAX-8-PG-11MAX-9-PG-11

D-80TP-11

D-90TP-11

D-80TP-7

MAX-ROD

I-FME-XS

I-RATCHET / I-TW-45

I-SP-X

D-90TP-7

D-80TP-9

D-90TP-9

I-CON-X

I-CS-HD

I-KEY-22

I-HD-S

MAX-9-PG-9

MAX-9-PG-7

MAX-8-PG-9

MAX-8-PG-7

I-MAX

I-DRILL

13

Trays and instruments are sold separately.

Externally Hexed Surgical Tray

ADDITIONAL DRILLS

ADDITIONAL INSTRUMENTS

Ø4x11.5Ø4x10

D-RB

Ø4x13 Ø4x15

Ø5x11.5Ø5x10 Ø5x13 Ø5x15

Ø6x11.5Ø6x10 Ø6x13 Ø6x15

WRENCH

CONNECTOR

OPEN WRENCH

DEPTH GAUGE

INSTRUMENTS

TWIST DRILLS

EXTENTIONS DIRECTIONINDICATORS

DRIVERS

D-20T D-29T

D-30T D-33T

D-40T D-43T

D-50T D-53T

HEX

1.22 HEX

0.9 HEX

FIXTURE MOUNT

DRILL

PLACEMENTTOOLS

D-RB

D-35T

D-20T

D-30T

LONGSHORT

Tri-Nex Surgical Tray

TWIST DRILLS

ADDITIONAL INSTRUMENTS

WRENCH

DEPTH GAUGE

INSTRUMENTS

EXTENTIONSDIRECTIONINDICATORS

DRIVERS

Ø4.3

Ø4.3

10

PLACEMENT TOOLS

LONGSHORT

LONGSHORT

Ø3.5

Ø3.5

Ø5.0

Ø5.0

LONGSHORT

Ø6.0

Ø6.0

8.5

11.5

13

16

10

8.5

11.5

13

16

10

8.5

11.5

13

16

10

8.5

11.5

13

16

Ø8.0

Ø9.0

9

11

9

11

14 Southern Implants Instrument CatalogueI I

I-TRI-NEX-U

I-HEX-U

Up

rig

ht

IT

Su

rg

ica

l T

ra

yZ

yg

om

at

ic I

ns

tr

um

en

t T

ra

y

This tray fit into the I-CASSETTE-2 and is autoclavable. Please see sterilizing and cleaning instructions on page 16.

Trays and instruments are sold separately.

I-HD I-CS-HD

I-CON-X

I-ZYG-DG-1

I-ZYG-DH

D-ZYG-RB

D-ZYG-29

D-ZYG-35

D-ZYG-CS

ZYG-TR-55-55

ZYG-TR-55-45

ZYG-TR-55-35

I-IT-U

I-ZYG

IT-Surgical Tray

15

Torque Wrenches / Ratchet

500 times or 3 years, whichever is reached first (service can extend life, but not indefinately).

Check whether the ratchet mechanism is working smoothly.

Do not expose to temperatures higher than 160°C.

Never store instruments while they are still wet or moist. This will result in corrosion and degradation of cutting edges. Inspect all instruments visually.

No Particular Requirements: It is recommended that instruments are cleaned and dried as soon as is reasonably practical following use.

Add one drop of handpiece oil to the internal mechanism after autoclaving.

Remove any connecting parts.

If detergent is not a high leveldisinfectant: Sonicate / rinse with 70 % ethanol for 5 minutes.

Rinse with luke-warm waterfor 3 minutes. Remove hardened soil with a sift bristle brush. Sonicate for 20 minutes in an ultrasonic cleaner using a detergent suitable for surgicalinstruments (SteriTech Instrument Cleaner - 5% dilution). Rinse in running water and dry.

In sets: Instruments can be loaded into dedicated instrument trays before sterilization. Place the tray in an appropriate sterilization bag.

Remove excess soil with running water.

Singly: A standard packaging material may be used. Ensure that the pack is large enough to contain the instrument without stressing the seal. (Recommendation: Use a packaging system that conforms to ISO 11607).

When sterilizing multiple instruments in one autoclave cycle, ensure the the sterilizer's maximum load is not exceeded. Refer to sterilizer's instructions for use. Ascertain the size of the instrument trays prior to sterilization.

Never store instruments while they are still wet or moist. This will result in corrosion and degradation of cutting edges.

Surgical and Prosthetic Trays

Repeated processing has minimal effect on these trays.

Rinse in luke-warm water and remove soil with a soft bristle brush and enzymatic detergent. Rinse off with luke-warm water and dry.

Do not expose to temperatures higher than 140°C.

Manual cleaning is not practical and is therefore discounted.

Remove excess soil withdisposable cloth / paper wipe.

Trays can be wiped / sprayeddown with 70 % ethanol.

No Particular Requirement.

Allow components to dry completely before sterilizing.

Autoclave at 121 ° C (250 ° F) for a minimum of 30 minutes.

Inspect all instruments visually for damage and bluntness.

Damaged or blunt instruments should not be used.

Instructions

Surgical and Prosthetic Tools

Drivers and General Instruments - Repeated processing has minimal effect.

Bone Mills - 15 times.

Taps, Tissue Punch, Osteotomes, counter bores, Thread cutters - 40 times.

Rinse with luke-warm waterfor 3 minutes. Remove hardened soil with a sift bristle brush. Sonicate for 20 minutes in an ultrasonic cleaner using a detergent suitable for surgicalinstruments (SteriTech Instrument Cleaner - 5% dilution). Rinse in running water and dry.

If detergent is not a high leveldisinfectant: Sonicate / rinse with 70 % ethanol for 5 minutes.

Disassembly from Handpiece.

Cleaning & Sterilization Procedure Guidelines

Remove excess soil with running water.

Never use blunt or damaged tools.

16 Southern Implants Instrument CatalogueI I

Disassembly from Handpiece.

Rinse with luke-warm waterfor 3 minutes. Remove hardened soil with a sift bristle brush. Sonicate for 20 minutes in an ultrasonic cleaner using a detergent suitable for surgicalinstruments (SteriTech Instrument Cleaner - 5% dilution). Rinse in running water and dry.

If detergent is not a high leveldisinfectant: Sonicate / rinse with 70 % ethanol for 5 minutes.

Taper Drills and Pilot Drills - 40 times.

Trephine Drills - 10 times.

Remove excess soil with running water.

Never use blunt or damaged tools.

Surgical Drills

Preparation for cleaning

Cleaning: Automated

Additional Information

Containment and Transportation

Cleaning: Manual

Limitations on Reprocessing

Inspection and further Testing

Components

Point of use:

Maintenance

Disinfection

Sterilization

Packaging

Warnings

Storage

Drying

STERILE R

2

!

Externally Hexed Product Catalogue Tri-Nex Product CatalogueIT Product CataloguePatient Information BrochurePatient Homecare BrochureOverdenture Information BrochureZygomatic Information BrochureProsthetic & Laboratory ManualCranio Facial ReconstructionTMJ Prosthesis CataloguePassive AbutmentsOne Piece ImplantsFinger Implants CatalogueFirst & Secondary Stage Surgery ManualInstructions for use

...................................................................................................................................................................

................................................................................................................................................................................................................................ ............................................

............................... .............................................................................. ............................................

..............................................................................................................................................................................

.......................................................................................................................................................................................................

...........................................................................................................................................................

...................................................................................................

CAT-2020CAT-2004CAT-2005CAT-2022

.. CAT-2023

.. CAT-2032

.. CAT-2025...............................................................................CAT-2001

CAT-2036 CAT-2018CAT-1008CAT-1083CAT-2010CAT-2024PRO-6038

The following symbols are used on our packaging labels and they indicate the following:

1: “Use by”

2: “Batch code”

3: “Do not reuse”

4: “Sterilization using Irradiation”

5: “Caution”

6: “Consult instruction for use”

7: CE mark

Southern Implants (Pty) Ltd. Irene, South Africa

Complimentary Manuals & Instructions:

Labeling Symbols:

i

Southern ImplantsTel: +49 7121 490 620Fax: +49 7121 491 [email protected]

Germany

NamibiaSkydancerTel: +64 61 225 152Fax: +64 61 235 [email protected]

TurkeyEkodentTel: +212 343 [email protected]

New ZealandSouthern Implants Ltd NZTel: 0800 246 752Cel: +64 2189 4243Fax: +64 9 430 [email protected]

AustraliaHenry Schein I Halas DentalTel: +61 2 9697 6288Fax: +61 2 9697 [email protected]

Spain / PortugalContactodentTel: +351 214 693 332Fax: +351 214 693 [email protected]

EXPANDING PROVEN CONCEPTS

United KingdomSouthern Implants UKTel: +44 208 998 0063Fax: +44 208 997 [email protected]

Nordic CountriesProtera ABTel: +46 31 291078Fax: +46 706 [email protected]

Americas / AsiaSouthern Implants Inc.Tel: +1 949 273 8505 Fax: +1 949 273 [email protected] www.southernimplants.us

BeneluxProScan bvbaTel: +32 11 822 650Fax: +32 11 822 [email protected]

South AfricaSouthern Implants (Pty) Ltd.Tel: +27 12 667 1046Fax: +27 12 [email protected]

GreeceSouthern ImplantsTel: +30 210 898 2817Fax: +30 210 595 [email protected]