2
NEW ! IMPULSE WINDING TESTERAND MICRO WAVE SENSOR Definitive solution of partial discharge test in electric windings. DWX-05PD A narrowband microwave sensor detects the electromagnetic waves of partial discharges, which are generated in a coil through a surge impulse with a fast rising front. PD examination of a sensitivity previously unknown in the coil winding industry ! In addition to the turn and layer short test of windings, it allows easy and fully automatic partial discharge tests within a coil for applications in production, QC and research/lab. This includes the recording of PD inception voltage (PDIV). Microwave antenna

NEW - Volta · DWX-05PD Specification Waveform of a normal coil Waveform of a shorted coil Example of waveforms with partial electrical discharge Impulse winding tester (Winding.)

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

  • NEW !

    IMPULSE WINDING TESTER AND MICRO WAVE SENSOR

    Definitive solution of partial discharge test in electric windings.

    DWX-05PD

    A narrowband microwave sensor detects the electromagnetic waves of partial

    discharges, which are generated in a coil through a surge impulse with a fast rising

    front.

    PD examination of a sensitivity previously unknown in the

    coil winding industry !

    In addition to the turn and layer short test of windings, it allows easy and fully

    automatic partial discharge tests within a coil for applications in production,

    QC and research/lab. This includes the recording of PD inception voltage (PDIV).

    Microwave antenna

  • Waveform of a normal coil Waveform of a shorted coil

    Example of waveforms with partial electrical discharge

    Impulse winding tester

    (Winding.)

    ImpulseSurge 0.5~5kV

    . Electrical discharge generation

    Microwave sensorSignal wave form

    Impulse test waveform

    microwaveantenna

    Micro wave sensorAmplifier and Filter circuit

    DWX-05PD Outline

    ●Impulse test specifications

    Range of test piece inductance 10μH or more (recommendation)

    Sampling speed 8 bit / 10 ns (100MS/s)

    Sampling memory 8 kByte

    Test voltage 300V~5900V(100V step)

    Voltage divider (impedance) resistive (5MΩ)

    ●Partial electrical discharge test specifications

    Micro wave sensorIt is sensing the electric discharge electromagnetic wave by a narrowband

    plane patch antenna

    Detection sensitivity -90db~-30db Within 30cm from item to be examined

    Antenna size/cable length to main unit W = 80mm H = 80mm D = 10mm cable length = 2m

    ●General

    Screen display

    Range of waveform display

    640×480 8.4 inch TFT color liquid crystal

    512×256

    Judgment methods

    Area of a comparison system waveform with a master waveform

    Differential Area examination ・Corona judgment by amount of electrical

    discharge, Laplacian method

    Partial electrical discharge inception voltage (PDIV)・ the automatic

    examination of those pulses of a test sequence with partial discharge・

    Electric discharge level

    Master wave form storage method 210 files in RAM memory, backup to Compact Flash card (up to 700).

    External interfacesParallel I/O ( Control ) RS-232C ( enhanced control ,test data I/O )

    Printerport (Screen Hard copy) Ethernet(Option)

    physical size W = 342mm H = 188mm D = 355mm Weight 12kg

    Operating condition 0℃~40℃、Power-supply voltage:100V~240V ±5%

    DWX-05PD SpecificationSignal wave form of electrical PD