VAPORIZERTHERMACASTTM ELECTRIC
Replaceable stainless steel cartridge heatersNEMA 4 Electrical CabinetAdjustable outlet temperature from 40°F to 120°FFully automa c opera onCompact designRedundant high temperature switches for safetyStainless steel cas ng jacket with insula on for corrosion resistance, low maintenance, improved appearance, and safetyThermacast™ unit comes fully factory wired, tested and ready to installQuick delivery of standard unitsBuilt in conformance with ASME B31.3 Process Piping Code300 series Stainless Steel/Brass we ed partsDesign pressure of 1,000 PSIG (Combo op on reduces MAWP to 500 PSIG)Terminals to allow for emergency shutdownDry contacts for main contractor ON and high blocktemperature limitAuxiliary 120V terminals (2 A max.) The components and electrical cabinet are all UL/cUL marked, and the hea ng elements are all UL recog-nized and CSA cer fied. All-Canada CRN
Standard features
Low Temperature Cut Off (LTCO) Kit featuring a temperature sensor and solenoid valve to prevent the flow of cold gas or liquid downstream of the vaporizer, 500 PSIG MAWP (add on item to any unit)Combo units with addi onal vaporiza on circuit for pressure building. Thermacast™ vaporizers in 15, 30 and 50 kW ra ngs have main coils for process vaporiza on and smaller secondary coils for pressure building. The pressure building coil comes with a pressure switch and solenoid valve to maintain the pressure in a CO2 tank. Pressure switch is adjustable from 100 to 375 PSIG“All-Weather” Package including NEMA 4X main high-voltage cabinet and side 120V cabinet, and internal cabinet heaterJunc on box with remote cabinet for hazardous area installa on
Standard Options
Product Datasheet 1.0
•
•••••
•
•
•
••
•
•
•
•
•
Simplified Flow DiagramSimplified Flow Diagram
Cryogenic Tank
Thermacast™ Vaporizer
Gas to Use Point Temperature set point is adjustable
Op onal LTCO
•
•
•
•
Thermacast™ units for Argon, Helium, Carbon Monoxide, Ethanol, Ammonia, Chlorine, Ethylene, Methanol, SO2, N2O, etc.Gas outlet temperature from -40°F to 400°FDesign pressure to 12,000 PSIGHigh Purity, electropolished unitsMonel, Hastelloy or 316 Stainless Steel we ed part construc on materialsClass 1, Division 2, Group B, C, or D Hazardous Area Purge PackageRemote Cabinet Op onCustom Inlet/Outlet Connec ons or FlangesCustom controls and contacts
Custom Options•
•
•
••
•
•
•
•
•
© 2019 Chart Inc. P/N 20979877
+1 508 999 1231
www.thermaxinc.com540 Hawthorn St. · Dartmouth, MA 02747 USA
Note: If the actual voltage differs from the design voltage of the vaporizer, the power and capacity will be effected by the ra o of (Vactual ÷ Vdesign)2.All tables shown in this Datasheet are intended as a guide that reflect our experience on these models. Actual performance may vary. Please call Thermax Inc. for guidance on specific applica ons.
* Includes pressure switch and solenoid valve on outlet of PB circuit* 500 PSIG MAWP* Nominal power and capacity based on standard heater tolerances: +5/-10%* For 150 PSIG CO₂, the capacity will be de-rated by an additional 10%* For larger CO₂ applications, Thermax recommends a Thermacast™ for process and an Electric Side Arm (L224) for pressure building
* TV3 and TV7 are single phase units* Nominal power and capacity based on standard heater tolerances: +5/-10%* For 150 PSIG CO₂, the capacity will be de-rated by an additional 10%
NEMA 4 Electrical Control Cabinet
High Temperature Insulated Leads
High Temperature Switches for Safety
Replaceable Cartridge Heaters
Temperature Controller
Pipe Connection:
Inlet
Outlet
Thermax Vortex Coil Flow Vaporizer
Stainless Steel Jacket with Insulation
TV3 and TV7 are single phase wall mount units:
Standard Dimensions: 24” high x 20” wide x 12” deep