4
Automated Microorganism Identification Device Identification of gram negative and gram positive bacteria within 3-minutes ! It enables the identification of small quantities of microbes (1-3 CFU) from a primary culture dish, within a couple of minutes. OptiDet ® devices comprised of two parts: (a) the main unit which performs the measurement and analysis and is the size of a table top printer; and (b) a disposable optical cell which accommodates the sample and is the size of a stethoscope chest piece. OptiDet ® technology is based on absorption spectroscopy combined with a proprietary device design, optical removable or disposable cell, and classification algorithms. New Technology - Accurate - Fast - Cost Effective

New Technology - Accurate - Fast - Cost EffectiveOptiDet® technology is based on absorption spectroscopy combined with a proprietary device design, optical removable or disposable

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: New Technology - Accurate - Fast - Cost EffectiveOptiDet® technology is based on absorption spectroscopy combined with a proprietary device design, optical removable or disposable

Automated Microorganism Identification Device

Identification of gram negative and gram positive bacteria within 3-minutes !

It enables the identification of small quantities of microbes (1-3 CFU) from a primary culture dish, within a couple of minutes. OptiDet® devices comprised of two parts: (a) the main unit which performs the measurement and analysis and is the size of a table top printer; and (b) a disposable optical cell which accommodates the sample and is the size of a stethoscope chest piece.

OptiDet® technology is based on

absorption spectroscopy combined

with a proprietary device design,

optical removable or disposable cell,

and classification algorithms.

New Technology - Accurate - Fast - Cost Effective

Page 2: New Technology - Accurate - Fast - Cost EffectiveOptiDet® technology is based on absorption spectroscopy combined with a proprietary device design, optical removable or disposable

Automated Microorganism Identification Device

Bacterial identification:

1. Samples are collected from patients and sent to the clinical laboratory.2. The laboratory technician plates the sample on a primary, non specific, petri dish for 18 - 24 hours.3. Technician picks up one colony from dish and smears it on a disposable unit.4. The unit is inserted to a stationary system.5. Result of a specific bacteria appears on the screen in 1-3 minutes.

Sample result found

Disposable

1

2

3

4

5

Technology :

Steps 1&2 are standard procedures.Steps 3,4,5: OptiDet® technology!

Page 3: New Technology - Accurate - Fast - Cost EffectiveOptiDet® technology is based on absorption spectroscopy combined with a proprietary device design, optical removable or disposable

WWW.ADALTIS.NET

Automated Microorganism Identification Device

Result

Upgrade Your LaboratoryNo more Standard Methods in Microbial Identification !

n Please turn on its power switch located at the rear panel. n Open the sterility pack and place the disposable on the working surface, with its mirror facing up. n Remove the sterile swab from its tube and collect a primary colony from the primary agar dish.n Smear the swab content evenly on the disposable unit using confluent strokes. n Open the removable handle and place the disposable into the removable compartment.n Place the handle back into the device and touch the “identify “icon that appears on the screen. n Wait for the microbial ID to appear on the screen. Time to result is 1-3 minutes.

To operate the OptiDet® it’s easy ! The technology solution for Small and Mid-size Labs

Adaltis laboratory device - Faster, Better, Cheaper

Page 4: New Technology - Accurate - Fast - Cost EffectiveOptiDet® technology is based on absorption spectroscopy combined with a proprietary device design, optical removable or disposable

© Nov. 2015 Ref. BRO1015 V1.2 ADALTIS S.r.l. All rights reserved. All trademarks are property of their respective owners. Specifications are subject to change without prior notice.

Sales and Marketing Officee-mail: [email protected]

Order handling and Logisticse-mail: [email protected]

Customer Care Center:e-mail: [email protected]

Technical Assistance:e-mail: [email protected]

Adaltis S.r.l. HeadquarterProduction and Development Plant

Via Luigi Einaudi 7Guidonia di Montecelio00012 Rome, Italy

Tel: + 39 0774 5791

Fax. + 39 0774 353085

Legal Registered OfficeVia Durini, 2720122 Milano, Italy

For more information

WWW.ADALTIS.NET

ADALTIS is certified in compliance with ISO9001 and ISO 13485. Our products are CE-IVD.

n Acinetobacter Baumanniin Enterobacter Aerogenesn Enterococcus Faecalisn Enterococcus Faeciumn Enterobactern Escherichia Coli

n Klebsialla Pneumoniaen Pseudomonas Aeruginosan Proteus Mirabilisn Staphylococcus Aureusn Staphyloccocus Epidermidisn Streptococcus Pyogenes

... more to come

a The device classifies correctly the microorganisms with over 90%

specificity and sensitivity compared to today’s culture methods.a The device will be able to identify

All bacteria and yeasts in the clinical laboratory. a No need for gram stains.a No need for specific culturing. a No reagents are needed.a Reduced culture preparation time - saves up to 48 hours

of additional bacteria growth in a medium.

OptiDet® accurately detects the twelve most common pathogens.

The technology can be used for other applications such as detection of bacteria directly from wounds and burns and can be also used for agricultural and homeland security applications.

[email protected]