Upload
others
View
6
Download
0
Embed Size (px)
Citation preview
P-9
P-3
P-1
P-2
P-7
P-4
P-4
P-4
P-1
P-1
P-1
P-6
P-5
P-1
WH-1
WH-2
CONNECT TO EXISTING 2"
SANITARY
CONNECT TO EXISTING 4"
UNDERGROUND
2" SANITARY
CONNECT TO EXISTING UNDERGROUND 4" SANITARY
FD
UNDERGROUND 2" SANITARY
4" SANITARY UP TO PIPING IN CHASE
4" SANITARY UP TO ABOVE
CONNECT TO EXISTING UNDERGROUND 4" SANITARY
4" SANITARY UP TO PIPING IN CHASE
UNDERGROUND 2" SANITARY
CONNECT TO EXISTING 2"
UNDERGROUND
CONNECT TO EXISTING 4"
UNDERGROUND
4" SANITARY
2" SANITARY
P-9
WH-2
EUP
DISCHARGE TO GRADE
EUP
DISCHARGE TO GRADE
EUP
DISCHARGE TO GRADE
EUP
DISCHARGE TO GRADE
EUP
DISCHARGE TO GRADE
EUP
DISCHARGE TO GRADE
EUP
DISCHARGE TO GRADE
EUP
DISCHARGE TO GRADE
EUP
DISCHARGE TO GRADE
FD
FROM ABOVE
FROM ABOVE
Date:Drawn By: Contract
Checked By:
Seal:
Update:
Drawing No:
Last
Project No: Scale:
Chk By
Building R
enovations
Salisbury M
anagem
ent
NE
W S
TO
RY
S
CH
OO
L
1245 P
erkiom
en A
venue
Reading, B
erks C
ounty, P
A 19602
Activities
Revisions:
Drawing Title:
Date Dwg By
PROPERTY RIGHTS ARE EXPRESSLY RESERVED BY Olsen Design Group Architects, Inc.
MANNER EXCEPT PURSUANT TO CONTRACT WITH OR WITH THE SPECIFIC
MAY BE AMENDED, REPRODUCED, COPIED OR USED IN ANY FORM OR
ALL RIGHTS RESERVED, NEITHER ALL NOR ANY PART OF THIS DOCUMENT
WRITTEN PERMISSION OF Olsen Design Group Architects, Inc.
COPYRIGHT 2016
2345 Bernville Road
Reading, PA 19605
610.371.9606
Fax 610.371.9607
www.odgarchitects.com
SUSTAINABLE
PLANNING
ARCHITECTURE
INTERIOR DESIGN
Multani Associates, Inc.
955 Penn Avenue
Wyomissing, PA 19610
610-374-0821 (FAX) 610-374-7071
HVAC/PLUMBING
CONTRACTOR
HV
AC
- P
LU
MB
IN
G
336 H
OS
TE
TT
ER
R
OA
D
MA
NH
EIM
, P
A 17545
PH
ON
E: (717) 665-0270
FA
X: (717) 665-0271
GA
RD
EN
S
PO
T M
EC
HA
NIC
AL, IN
C
JAM
ES A.
KO
PPEN
HAVER P.E.
304 LO
GAN
AVEN
UE
W
YO
MISSIN
G
PA 19610
484-794-9949
ENGINEER OF
RECORD
PLUMBING LEGEND
P-? PLUMBING FIXTURE AND MARK
SANITARY PIPING (SAN)
SANITARY VENT PIPING (VENT)
COLD WATER PIPING (CW)
HOT WATER PIPING (HW)
RECIRCULATED LOOP PIPING (HWR)
WH WATER HEATER
CP CIRCULATION PUMP
FD FLOOR DRAIN
FCO FLOOR CLEANOUT
CU COPPER PIPING
TYP TYPICAL
WCO WALL CLEAN OUT
CHECK VALVE
VTR VENT THROUGH ROOF
RPZ REDUCED PRESSURE ZONE
BALL VALVE
RD ROOF DRAIN
OFRD OVERFLOW ROOF DRAIN
HOSE BIB
WATER HAMMER ARRESTER (WHA)
CONNECT TO EXISTING
P-9
P-3
P-1
P-2
P-7
P-4
P-4
P-4
P-1
P-1
P-1
P-6
P-5
P-1
WH-1
2" SANITARY UP TO P-7 ABOVE
2" SANITARY UP TO P-5 ABOVE
WH-2
CONNECT TO EXISTING 4"
VENT STACK
CONNECT TO EXISTING 4"
VENT STACK
CONNECT TO EXISTING 2"
VENT STACK
2" VENT
2" SANITARY
CONNECT TO EXISTING 2" VENT
2" SANITARY
2" VENT
2" VENT
KEY IDENTIFICATION
1 4" SANITARY
2" VENT
1" COLD WATER
2 2" SANITARY
2" VENT
3
4
" COLD WATER
3 2" SANITARY
2" VENT
1
2
" COLD WATER
1
2
" HOT WATER
4 2" SANITARY
1
1
2
" VENT
1
2
" COLD WATER
1
2
4
1
3
3
1
1
1
3
3
3
3
WCO
WCO
CO
EXISTING 4" SANITARY UP TO FLOOR ABOVE
FD
FD
EXT
1
1
2
" VENT
2" SANITARY DOWN TO UNDERGROUND
4" SANITARY TO UNDERGROUND
4" SANITARY TO UNDERGROUND
EXISTING 4" SANITARY UP TO FLOOR ABOVE
4" SANITARY UP TO CEILING
CONTINUED ON P-1.2
EXISTING SUMP PUMP TO REMAIN
PLUMBING CONTRACTOR TO CONFIRM OPERATION
ACCESS PANEL IS REQUIRED FOR MAINTENANCE
1
1
2
" VENT
1
1
2
" VENT
VERTICAL CARRIER
4" SANITARY DOWN TO BELOW FLOOR
P-9
3
1
WH-2
EUP
DISCHARGE TO GRADE
EUP
DISCHARGE TO GRADE
EUP
DISCHARGE TO GRADE
EUP
DISCHARGE TO GRADE
EUP
DISCHARGE TO GRADE
EUP
DISCHARGE TO GRADE
EUP
DISCHARGE TO GRADE
EUP
DISCHARGE TO GRADE
EUP
DISCHARGE TO GRADE
FD
EXISTING SUMP PUMP TO REMAIN
PLUMBING CONTRACTOR TO CONFIRM OPERATION
ACCESS PANEL IS REQUIRED FOR MAINTENANCE
DOWN TO UNDERGROUND
Date:Drawn By: Contract
Checked By:
Seal:
Update:
Drawing No:
Last
Project No: Scale:
Chk By
Building R
enovations
Salisbury M
anagem
ent
NE
W S
TO
RY
S
CH
OO
L
1245 P
erkiom
en A
venue
Reading, B
erks C
ounty, P
A 19602
Activities
Revisions:
Drawing Title:
Date Dwg By
PROPERTY RIGHTS ARE EXPRESSLY RESERVED BY Olsen Design Group Architects, Inc.
MANNER EXCEPT PURSUANT TO CONTRACT WITH OR WITH THE SPECIFIC
MAY BE AMENDED, REPRODUCED, COPIED OR USED IN ANY FORM OR
ALL RIGHTS RESERVED, NEITHER ALL NOR ANY PART OF THIS DOCUMENT
WRITTEN PERMISSION OF Olsen Design Group Architects, Inc.
COPYRIGHT 2016
2345 Bernville Road
Reading, PA 19605
610.371.9606
Fax 610.371.9607
www.odgarchitects.com
SUSTAINABLE
PLANNING
ARCHITECTURE
INTERIOR DESIGN
Multani Associates, Inc.
955 Penn Avenue
Wyomissing, PA 19610
610-374-0821 (FAX) 610-374-7071
HVAC/PLUMBING
CONTRACTOR
HV
AC
- P
LU
MB
IN
G
336 H
OS
TE
TT
ER
R
OA
D
MA
NH
EIM
, P
A 17545
PH
ON
E: (717) 665-0270
FA
X: (717) 665-0271
GA
RD
EN
S
PO
T M
EC
HA
NIC
AL, IN
C
JAM
ES A.
KO
PPEN
HAVER P.E.
304 LO
GAN
AVEN
UE
W
YO
MISSIN
G
PA 19610
484-794-9949
ENGINEER OF
RECORD
PLUMBING LEGEND
P-? PLUMBING FIXTURE AND MARK
SANITARY PIPING (SAN)
SANITARY VENT PIPING (VENT)
COLD WATER PIPING (CW)
HOT WATER PIPING (HW)
RECIRCULATED LOOP PIPING (HWR)
WH WATER HEATER
CP CIRCULATION PUMP
FD FLOOR DRAIN
FCO FLOOR CLEANOUT
CU COPPER PIPING
TYP TYPICAL
WCO WALL CLEAN OUT
CHECK VALVE
VTR VENT THROUGH ROOF
RPZ REDUCED PRESSURE ZONE
BALL VALVE
RD ROOF DRAIN
OFRD OVERFLOW ROOF DRAIN
HOSE BIB
WATER HAMMER ARRESTER (WHA)
CONNECT TO EXISTING
P-5
P-5
P-4
P-2
P-1
P-7
P-1
P-4
P-1
P-1
P-4
P-4
P-7
P-1
P-1
P-2
P-1
WH-1
2" SANITARY DOWN TO BELOW
2" SANITARY DOWN TO BELOW
2" SANITARY DOWN FROM P-6 ABOVE
2" SANITARY DOWN TO BELOW
2" SANITARY DOWN FROM P-4 ABOVE
2" SANITARY DOWN TO BELOW
2" VENT UP TO ABOVE
CONNECT TO EXISTING 4" VENT STACK
KEY IDENTIFICATION
1 4" SANITARY
2" VENT
1" COLD WATER
2 2" SANITARY
2" VENT
3
4
" COLD WATER
3 2" SANITARY
2" VENT
1
2
" COLD WATER
1
2
" HOT WATER
4 2" SANITARY
1
1
2
" VENT
1
2
" COLD WATER
1
1
1
1
1
1
2
1
3
3
4
2
4
3
3
3
3
CONNECT TO EXISTING 4" VENT STACK
2" VENT
2" VENT
4" VERTICAL CARRIER
4" SANITARY DOWN TO EXISTING STACK BELOW
CONNECT TO EXISTING 4"
SANITARY STACK BELOW
WCO
WCO
WCO
WCO
FD
FD
FD
FD
4" SANITARY FROM FLOOR ABOVE
OVER AND DOWN TO CHASE PIPING
2" SANITARY BELOW FLOOR
2" SANITARY BELOW FLOOR
CO
3" SANITARY DOWN TO STACK BELOW
VERTICAL CARRIER
4" SANITARY DOWN TO BELOW FLOOR
2" SANITARY BELOW FLOOR
2" SANITARY ABOVE CEILING
2" SANITARY DOWN IN CHASE
4" SANITARY IN CHASE
4" SANITARY IN CHASE
2" SANITARY BELOW FLOOR
1
1
2
" VENT
1
1
2
" VENT
2" VENT
2" VENT
4" VERTICAL CARRIER
4" SANITARY DOWN TO EXISTING STACK BELOW
2" SANITARY IN CHASE
SANITARY BELOW FLOOR
CONNECT TO EXISTING 4"
SANITARY STACK BELOW
4" SANITARY IN CHASE
2" VENT ABOVE CEILING
2" VENT ABOVE CEILING
2" VENT ABOVE CEILING
2" BELOW FLOOR
4" DOWN FROM ABOVE
FROM P-7 ABOVE
P-11
4" SAN BELOW FLOOR
VERTICAL CARRIER
4" SANITARY DOWN TO BELOW FLOOR
CO
2" SANITARY DOWN TO BELOW
2" SANITARY BELOW FLOOR
P-4 3
Date:Drawn By: Contract
Checked By:
Seal:
Update:
Drawing No:
Last
Project No: Scale:
Chk By
Building R
enovations
Salisbury M
anagem
ent
NE
W S
TO
RY
S
CH
OO
L
1245 P
erkiom
en A
venue
Reading, B
erks C
ounty, P
A 19602
Activities
Revisions:
Drawing Title:
Date Dwg By
PROPERTY RIGHTS ARE EXPRESSLY RESERVED BY Olsen Design Group Architects, Inc.
MANNER EXCEPT PURSUANT TO CONTRACT WITH OR WITH THE SPECIFIC
MAY BE AMENDED, REPRODUCED, COPIED OR USED IN ANY FORM OR
ALL RIGHTS RESERVED, NEITHER ALL NOR ANY PART OF THIS DOCUMENT
WRITTEN PERMISSION OF Olsen Design Group Architects, Inc.
COPYRIGHT 2016
2345 Bernville Road
Reading, PA 19605
610.371.9606
Fax 610.371.9607
www.odgarchitects.com
SUSTAINABLE
PLANNING
ARCHITECTURE
INTERIOR DESIGN
Multani Associates, Inc.
955 Penn Avenue
Wyomissing, PA 19610
610-374-0821 (FAX) 610-374-7071
HVAC/PLUMBING
CONTRACTOR
HV
AC
- P
LU
MB
IN
G
336 H
OS
TE
TT
ER
R
OA
D
MA
NH
EIM
, P
A 17545
PH
ON
E: (717) 665-0270
FA
X: (717) 665-0271
GA
RD
EN
S
PO
T M
EC
HA
NIC
AL, IN
C
JAM
ES A.
KO
PPEN
HAVER P.E.
304 LO
GAN
AVEN
UE
W
YO
MISSIN
G
PA 19610
484-794-9949
ENGINEER OF
RECORD
PLUMBING LEGEND
P-? PLUMBING FIXTURE AND MARK
SANITARY PIPING (SAN)
SANITARY VENT PIPING (VENT)
COLD WATER PIPING (CW)
HOT WATER PIPING (HW)
RECIRCULATED LOOP PIPING (HWR)
WH WATER HEATER
CP CIRCULATION PUMP
FD FLOOR DRAIN
FCO FLOOR CLEANOUT
CU COPPER PIPING
TYP TYPICAL
WCO WALL CLEAN OUT
CHECK VALVE
VTR VENT THROUGH ROOF
RPZ REDUCED PRESSURE ZONE
BALL VALVE
RD ROOF DRAIN
OFRD OVERFLOW ROOF DRAIN
HOSE BIB
WATER HAMMER ARRESTER (WHA)
CONNECT TO EXISTING
P-4
P-1
P-4
P-4
P-1
P-1
P-1
P-2
P-7
P-6
P-1
2" VENT UP FROM BELOW
2" SANITARY DOWN TO BELOW
4" VERTICAL CARRIER
4" SANITARY DOWN TO BELOW
2" SANITARY DOWN TO BELOW
2" SANITARY DOWN BELOW FLOOR
2" VENT ABOVE
CEILING
2" VENT ABOVE CEILING
KEY IDENTIFICATION
1 4" SANITARY
2" VENT
1" COLD WATER
2 2" SANITARY
2" VENT
3
4
" COLD WATER
3 2" SANITARY
2" VENT
1
2
" COLD WATER
1
2
" HOT WATER
4 2" SANITARY
1
1
2
" VENT
1
2
" COLD WATER
1 2
3
3
1
1
3
3
3
3" VTR
4" VERTICAL CARRIER
4" SANITARY DOWN TO BELOW
CONNECT TO EXISTING 4"
VENT STACK
2" VENT ABOVE CEILING TO
EXISTING VENT STACK
WCO
WCO
WCO
FD
FD
2" IN CHASE
2" VENT ABOVE
CEILING
4" SANITARY BELOW FLOOR
CONNECT TO EXISTING STACK
2" SANITARY BELOW FLOOR
CONNECT TO EXISTING STACK
4" SANITARY IN CHASE
WCO
1
1
2" SANITARY DOWN TO BELOW
Date:Drawn By: Contract
Checked By:
Seal:
Update:
Drawing No:
Last
Project No: Scale:
Chk By
Building R
enovations
Salisbury M
anagem
ent
NE
W S
TO
RY
S
CH
OO
L
1245 P
erkiom
en A
venue
Reading, B
erks C
ounty, P
A 19602
Activities
Revisions:
Drawing Title:
Date Dwg By
PROPERTY RIGHTS ARE EXPRESSLY RESERVED BY Olsen Design Group Architects, Inc.
MANNER EXCEPT PURSUANT TO CONTRACT WITH OR WITH THE SPECIFIC
MAY BE AMENDED, REPRODUCED, COPIED OR USED IN ANY FORM OR
ALL RIGHTS RESERVED, NEITHER ALL NOR ANY PART OF THIS DOCUMENT
WRITTEN PERMISSION OF Olsen Design Group Architects, Inc.
COPYRIGHT 2016
2345 Bernville Road
Reading, PA 19605
610.371.9606
Fax 610.371.9607
www.odgarchitects.com
SUSTAINABLE
PLANNING
ARCHITECTURE
INTERIOR DESIGN
Multani Associates, Inc.
955 Penn Avenue
Wyomissing, PA 19610
610-374-0821 (FAX) 610-374-7071
HVAC/PLUMBING
CONTRACTOR
HV
AC
- P
LU
MB
IN
G
336 H
OS
TE
TT
ER
R
OA
D
MA
NH
EIM
, P
A 17545
PH
ON
E: (717) 665-0270
FA
X: (717) 665-0271
GA
RD
EN
S
PO
T M
EC
HA
NIC
AL, IN
C
JAM
ES A.
KO
PPEN
HAVER P.E.
304 LO
GAN
AVEN
UE
W
YO
MISSIN
G
PA 19610
484-794-9949
ENGINEER OF
RECORD
PLUMBING LEGEND
P-? PLUMBING FIXTURE AND MARK
SANITARY PIPING (SAN)
SANITARY VENT PIPING (VENT)
COLD WATER PIPING (CW)
HOT WATER PIPING (HW)
RECIRCULATED LOOP PIPING (HWR)
WH WATER HEATER
CP CIRCULATION PUMP
FD FLOOR DRAIN
FCO FLOOR CLEANOUT
CU COPPER PIPING
TYP TYPICAL
WCO WALL CLEAN OUT
CHECK VALVE
VTR VENT THROUGH ROOF
RPZ REDUCED PRESSURE ZONE
BALL VALVE
RD ROOF DRAIN
OFRD OVERFLOW ROOF DRAIN
HOSE BIB
WATER HAMMER ARRESTER (WHA)
CONNECT TO EXISTING
P-9
P-3
P-1
P-2
P-7
P-4
P-4
P-4
P-1
P-1
P-1
P-6
P-5
P-1
WH-1
WH-2
2" UP TO 1ST FLOOR
1
1
2
" CW UP TO ABOVE
3
4
" HW UP TO ABOVE
EXISTING WATER SERVICE
2" CW
2" CW
2" CW 2" CW
1
2
" HW
1
2
" CW
1" CW
3
4
" CW
1
2
" CW
2" CW
1
1
2
" CW
3
4
" CW
1
2
" HW
1
2
" CW
1" CW
1" CW
1" CW
1" CW
3
4
" CW
1" CW
1
1
4
" CW
1
2
" HW
1
2
" HW
1
2
" CW
1
2
" HW
1
2
" CW
1
1
4
" CW
1
2
" HW
1
1
2
" CW
1
2
" HW
KEY IDENTIFICATION
1 4" SANITARY
2" VENT
1" COLD WATER
2 2" SANITARY
2" VENT
3
4
" COLD WATER
3 2" SANITARY
2" VENT
1
2
" COLD WATER
1
2
" HOT WATER
4 2" SANITARY
1
1
2
" VENT
1
2
" COLD WATER
1
2
4
1
3
3
1
1
1
3
3
3
CONNECT TO EXISTING 2" COPPER
WATER PIPING
LOCATION OF REDUCED PRESSURE
ZONE BACKFLOW VALVE AND
WATER METER
WHA
WHA
WHA
1
1
4
" CW
1
1
4
" CW
3
4
" CW
1
2
" HW
1
2
" CW
P-9
3
1
WH-2
EUP
DISCHARGE TO GRADE
EUP
DISCHARGE TO GRADE
EUP
DISCHARGE TO GRADE
EUP
DISCHARGE TO GRADE
EUP
DISCHARGE TO GRADE
EUP
DISCHARGE TO GRADE
EUP
DISCHARGE TO GRADE
EUP
DISCHARGE TO GRADE
EUP
DISCHARGE TO GRADE
Date:Drawn By: Contract
Checked By:
Seal:
Update:
Drawing No:
Last
Project No: Scale:
Chk By
Building R
enovations
Salisbury M
anagem
ent
NE
W S
TO
RY
S
CH
OO
L
1245 P
erkiom
en A
venue
Reading, B
erks C
ounty, P
A 19602
Activities
Revisions:
Drawing Title:
Date Dwg By
PROPERTY RIGHTS ARE EXPRESSLY RESERVED BY Olsen Design Group Architects, Inc.
MANNER EXCEPT PURSUANT TO CONTRACT WITH OR WITH THE SPECIFIC
MAY BE AMENDED, REPRODUCED, COPIED OR USED IN ANY FORM OR
ALL RIGHTS RESERVED, NEITHER ALL NOR ANY PART OF THIS DOCUMENT
WRITTEN PERMISSION OF Olsen Design Group Architects, Inc.
COPYRIGHT 2016
2345 Bernville Road
Reading, PA 19605
610.371.9606
Fax 610.371.9607
www.odgarchitects.com
SUSTAINABLE
PLANNING
ARCHITECTURE
INTERIOR DESIGN
Multani Associates, Inc.
955 Penn Avenue
Wyomissing, PA 19610
610-374-0821 (FAX) 610-374-7071
HVAC/PLUMBING
CONTRACTOR
HV
AC
- P
LU
MB
IN
G
336 H
OS
TE
TT
ER
R
OA
D
MA
NH
EIM
, P
A 17545
PH
ON
E: (717) 665-0270
FA
X: (717) 665-0271
GA
RD
EN
S
PO
T M
EC
HA
NIC
AL, IN
C
JAM
ES A.
KO
PPEN
HAVER P.E.
304 LO
GAN
AVEN
UE
W
YO
MISSIN
G
PA 19610
484-794-9949
ENGINEER OF
RECORD
PLUMBING LEGEND
P-? PLUMBING FIXTURE AND MARK
SANITARY PIPING (SAN)
SANITARY VENT PIPING (VENT)
COLD WATER PIPING (CW)
HOT WATER PIPING (HW)
RECIRCULATED LOOP PIPING (HWR)
WH WATER HEATER
CP CIRCULATION PUMP
FD FLOOR DRAIN
FCO FLOOR CLEANOUT
CU COPPER PIPING
TYP TYPICAL
WCO WALL CLEAN OUT
CHECK VALVE
VTR VENT THROUGH ROOF
RPZ REDUCED PRESSURE ZONE
BALL VALVE
RD ROOF DRAIN
OFRD OVERFLOW ROOF DRAIN
HOSE BIB
WATER HAMMER ARRESTER (WHA)
CONNECT TO EXISTING
P-5
P-5
P-4
P-2
P-1
P-7
P-1
P-4
P-1
P-1
P-4
P-4
P-7
P-1
P-1
P-2
P-1
WH-1
1
2
" HW
1
2
" CW
UP TO P-4 ABOVE
3
4
" HW
1
1
2
" CW
UP TO ABOVE
2" CW
UP FROM BELOW
1
2
" CW
1
2
" HW
1
2
" CW
1
2
" HW
1
2
" CW
1
1
4
" CW
1
2
" WH
1" CW
1" CW
1" CW
1" CW
3
4
" CW
1" CW
1
2
" HW
1
2
" CW
1
1
2
" CW
3
4
" HW
UP FROM BASEMENT
1
1
2
" CW
1
2
" WH
1
1
2
" CW
1
2
" WH
1
1
4
" CW
1
2
" WH
1
1
2
" CW
1
2
" WH
1
1
2
" CW
3
4
" WH
1
2
" HW
1
2
" CW
1" CW
1" CW
1" CW
1
2
" HW
1
2
" CW
1
2
" CW
1
2
" HW
1
2
" CW
1
2
" CW
1
2
" HW
KEY IDENTIFICATION
1 4" SANITARY
2" VENT
1" COLD WATER
2 2" SANITARY
2" VENT
3
4
" COLD WATER
3 2" SANITARY
2" VENT
1
2
" COLD WATER
1
2
" HOT WATER
4 2" SANITARY
1
1
2
" VENT
1
2
" COLD WATER
1
1
1
1
1
1
2
1
3
3
4
2
4
3
3
3
3
VALVE ON THE HOT AND
COLD CONNECTION
WHA
WHA
1
1
4
" CW
WHA
WHA
P-11
3
4
" CW
1
1
4
" CW
P-4 3
Date:Drawn By: Contract
Checked By:
Seal:
Update:
Drawing No:
Last
Project No: Scale:
Chk By
Building R
enovations
Salisbury M
anagem
ent
NE
W S
TO
RY
S
CH
OO
L
1245 P
erkiom
en A
venue
Reading, B
erks C
ounty, P
A 19602
Activities
Revisions:
Drawing Title:
Date Dwg By
PROPERTY RIGHTS ARE EXPRESSLY RESERVED BY Olsen Design Group Architects, Inc.
MANNER EXCEPT PURSUANT TO CONTRACT WITH OR WITH THE SPECIFIC
MAY BE AMENDED, REPRODUCED, COPIED OR USED IN ANY FORM OR
ALL RIGHTS RESERVED, NEITHER ALL NOR ANY PART OF THIS DOCUMENT
WRITTEN PERMISSION OF Olsen Design Group Architects, Inc.
COPYRIGHT 2016
2345 Bernville Road
Reading, PA 19605
610.371.9606
Fax 610.371.9607
www.odgarchitects.com
SUSTAINABLE
PLANNING
ARCHITECTURE
INTERIOR DESIGN
Multani Associates, Inc.
955 Penn Avenue
Wyomissing, PA 19610
610-374-0821 (FAX) 610-374-7071
HVAC/PLUMBING
CONTRACTOR
HV
AC
- P
LU
MB
IN
G
336 H
OS
TE
TT
ER
R
OA
D
MA
NH
EIM
, P
A 17545
PH
ON
E: (717) 665-0270
FA
X: (717) 665-0271
GA
RD
EN
S
PO
T M
EC
HA
NIC
AL, IN
C
JAM
ES A.
KO
PPEN
HAVER P.E.
304 LO
GAN
AVEN
UE
W
YO
MISSIN
G
PA 19610
484-794-9949
ENGINEER OF
RECORD
PLUMBING LEGEND
P-? PLUMBING FIXTURE AND MARK
SANITARY PIPING (SAN)
SANITARY VENT PIPING (VENT)
COLD WATER PIPING (CW)
HOT WATER PIPING (HW)
RECIRCULATED LOOP PIPING (HWR)
WH WATER HEATER
CP CIRCULATION PUMP
FD FLOOR DRAIN
FCO FLOOR CLEANOUT
CU COPPER PIPING
TYP TYPICAL
WCO WALL CLEAN OUT
CHECK VALVE
VTR VENT THROUGH ROOF
RPZ REDUCED PRESSURE ZONE
BALL VALVE
RD ROOF DRAIN
OFRD OVERFLOW ROOF DRAIN
HOSE BIB
WATER HAMMER ARRESTER (WHA)
CONNECT TO EXISTING
P-4
P-1
P-4
P-4
P-1
P-1
P-1
P-2
P-7
P-6
P-1
1
2
" HW
1
2
" CW
DOMESTIC UP FROM BELOW
1
2
" HW
1
1
2
" CW
1
2
" HW
1
2
" CW
1
2
" HW
1
2
" CW
1" CW
3
4
" CW
1" CW
1
2
" CW
1
2
" HW
1
2
" CW
1
2
" HW
3
4
" HW
1
1
2
" CW
UP FROM BELOW
KEY IDENTIFICATION
1 4" SANITARY
2" VENT
1" COLD WATER
2 2" SANITARY
2" VENT
3
4
" COLD WATER
3 2" SANITARY
2" VENT
1
2
" COLD WATER
1
2
" HOT WATER
4 2" SANITARY
1
1
2
" VENT
1
2
" COLD WATER
1 2
3
3
1
1
3
3
3
WHA
1
1
1" CW
Date:Drawn By: Contract
Checked By:
Seal:
Update:
Drawing No:
Last
Project No: Scale:
Chk By
Building R
enovations
Salisbury M
anagem
ent
NE
W S
TO
RY
S
CH
OO
L
1245 P
erkiom
en A
venue
Reading, B
erks C
ounty, P
A 19602
Activities
Revisions:
Drawing Title:
Date Dwg By
PROPERTY RIGHTS ARE EXPRESSLY RESERVED BY Olsen Design Group Architects, Inc.
MANNER EXCEPT PURSUANT TO CONTRACT WITH OR WITH THE SPECIFIC
MAY BE AMENDED, REPRODUCED, COPIED OR USED IN ANY FORM OR
ALL RIGHTS RESERVED, NEITHER ALL NOR ANY PART OF THIS DOCUMENT
WRITTEN PERMISSION OF Olsen Design Group Architects, Inc.
COPYRIGHT 2016
2345 Bernville Road
Reading, PA 19605
610.371.9606
Fax 610.371.9607
www.odgarchitects.com
SUSTAINABLE
PLANNING
ARCHITECTURE
INTERIOR DESIGN
Multani Associates, Inc.
955 Penn Avenue
Wyomissing, PA 19610
610-374-0821 (FAX) 610-374-7071
HVAC/PLUMBING
CONTRACTOR
HV
AC
- P
LU
MB
IN
G
336 H
OS
TE
TT
ER
R
OA
D
MA
NH
EIM
, P
A 17545
PH
ON
E: (717) 665-0270
FA
X: (717) 665-0271
GA
RD
EN
S
PO
T M
EC
HA
NIC
AL, IN
C
JAM
ES A.
KO
PPEN
HAVER P.E.
304 LO
GAN
AVEN
UE
W
YO
MISSIN
G
PA 19610
484-794-9949
ENGINEER OF
RECORD
PLUMBING LEGEND
P-? PLUMBING FIXTURE AND MARK
SANITARY PIPING (SAN)
SANITARY VENT PIPING (VENT)
COLD WATER PIPING (CW)
HOT WATER PIPING (HW)
RECIRCULATED LOOP PIPING (HWR)
WH WATER HEATER
CP CIRCULATION PUMP
FD FLOOR DRAIN
FCO FLOOR CLEANOUT
CU COPPER PIPING
TYP TYPICAL
WCO WALL CLEAN OUT
CHECK VALVE
VTR VENT THROUGH ROOF
RPZ REDUCED PRESSURE ZONE
BALL VALVE
RD ROOF DRAIN
OFRD OVERFLOW ROOF DRAIN
HOSE BIB
WATER HAMMER ARRESTER (WHA)
CONNECT TO EXISTING
HW 110°F
HWR
CW
EXPANSION TANK
WATER HEATER
DRAIN TO FLOOR DRAIN
BALL VALVE TYPICAL OF (3)
THERMOSTATIC MIXING VALVE
CHECK VALVE
RECIRCULATION PUMP
RELIEF VALVE
DRAIN VALVE
DRAIN PAN
UNION TYPICAL
Date:Drawn By: Contract
Checked By:
Seal:
Update:
Drawing No:
Last
Project No: Scale:
Chk By
Building R
enovations
Salisbury M
anagem
ent
NE
W S
TO
RY
S
CH
OO
L
1245 P
erkiom
en A
venue
Reading, B
erks C
ounty, P
A 19602
Activities
Revisions:
Drawing Title:
Date Dwg By
PROPERTY RIGHTS ARE EXPRESSLY RESERVED BY Olsen Design Group Architects, Inc.
MANNER EXCEPT PURSUANT TO CONTRACT WITH OR WITH THE SPECIFIC
MAY BE AMENDED, REPRODUCED, COPIED OR USED IN ANY FORM OR
ALL RIGHTS RESERVED, NEITHER ALL NOR ANY PART OF THIS DOCUMENT
WRITTEN PERMISSION OF Olsen Design Group Architects, Inc.
COPYRIGHT 2016
2345 Bernville Road
Reading, PA 19605
610.371.9606
Fax 610.371.9607
www.odgarchitects.com
SUSTAINABLE
PLANNING
ARCHITECTURE
INTERIOR DESIGN
Multani Associates, Inc.
955 Penn Avenue
Wyomissing, PA 19610
610-374-0821 (FAX) 610-374-7071
HVAC/PLUMBING
CONTRACTOR
HV
AC
- P
LU
MB
IN
G
336 H
OS
TE
TT
ER
R
OA
D
MA
NH
EIM
, P
A 17545
PH
ON
E: (717) 665-0270
FA
X: (717) 665-0271
GA
RD
EN
S
PO
T M
EC
HA
NIC
AL, IN
C
JAM
ES A.
KO
PPEN
HAVER P.E.
304 LO
GAN
AVEN
UE
W
YO
MISSIN
G
PA 19610
484-794-9949
ENGINEER OF
RECORD
SECTION 2 - MATERIALS
2.1 PIPING INSTALLATION
DOMESTIC WATER PIPING SHALL BE TYPE "K" COPPER FOR UNDERGROUND. ALL SOLDER SHALL BE TYPE 95-5
(NON-LEAD). PEX TYPE PIPING MAY BE USED IF APPROVED BY LOCAL CODE. PROVIDE 1" (TUBOLIT SS) BLACK
FLEXIBLE POLYOLEFIN/POLYETHYLENE THERMAL INSULATION IN TUBULAR FORM WITH A SELF-SEAL SYSTEM
MANUFACTURED BY ARMACELL FOR PEX PIPING AND INSTALLED PER MANUFACTURER'S RECOMMENDATIONS.
INSULATION SHALL HAVE THE "k" FACTOR OF 0.25 BTU-in/ft2 °F.
ROOF DRAINAGE PIPING SHALL BE POLYVINYL CHLORIDE (PVC) AND INSULATED WITH
1
2
" (TUBOLIT SS) BLACK
FLEXIBLE POLYOLEFIN/POLYETHYLENE THERMAL INSULATION IN TUBULAR FORM WITH A SELF-SEAL SYSTEM
MANUFACTURED BY ARMACELL AND INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. INSULATION SHALL
HAVE THE "k" FACTOR OF 0.25 BTU-in/ft2 °F.
ALL SANITARY WASTE AND VENT LINES SHALL BE STANDARD WEIGHT CAST IRON OR SCHEDULE 40 POLYVINYL
CHLORIDE (PVC) IF APPROVED BY LOCAL CODE. PROVIDE CLEANOUTS WHERE SHOWN AND WHERE REQUIRED
BY CODE OR FOR MAINTENANCE SERVICE
2.2 MISCELLANEOUS MATERIALS
ALL PIPES WHICH PASS THROUGH FINISHED WALLS, CEILINGS OR FLOORS SHALL BE PROVIDED WITH
ESCUTCHEON PLATES SECURELY FASTENED IN PLACE.
2.3 HANGERS AND SUPPORTS
HANGERS AND SUPPORTS FOR PIPING SHALL ALLOW FOR EXPANSION. BAND OR STRAP HANGERS ARE
ACCEPTABLE.
DIVISION 22 - PLUMBING
SECTION 1 - GENERAL CONDITIONS
1.1 SCOPE
THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE FOLLOWING INSTALLATIONS BUT IS NOT NECESSARILY
LIMITED BY THIS SUMMARY:
1. SANITARY WASTE, VENT AND DOMESTIC WATER PIPING.
2. VALVES.
1.2 RULES AND REGULATIONS
THE ENTIRE INSTALLATION SHALL BE INSTALLED IN STRICT ACCORDANCE WITH ALL NATIONAL, STATE AND LOCAL CODES OR
AGENCIES HAVING JURISDICTION.
THE CONTRACTOR SHALL PROVIDE FOR INSTALLATION, ALL NEW EQUIPMENT, AND MATERIALS OF THE BEST QUALITY AS
HEREIN SPECIFIED OR ILLUSTRATED ON THE ACCOMPANYING DRAWINGS; OR EQUALS AS APPROVED BY THE MECHANICAL
ENGINEER.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FEES AND PERMITS NECESSARY FOR ALL INSTALLATION. HE SHALL ALSO
PREPARE ANY SPECIFIC PLANS AND/OR ISOMETRIC DRAWINGS REQUIRED BY PROPER AUTHORITIES BEFORE ACCEPTANCE OF
WORK.
IT SHALL BE THE RESPONSIBILITY OF THIS CONTRACTOR TO FURNISH ALL REQUIRED LABOR, MATERIALS, AND SUPERVISION
NECESSARY FOR A COMPLETE INSTALLATION
1.3 WORK BY OTHERS
THE MECHANICAL CONTRACTOR SHALL SUPPLY ALL ELECTRICAL CONTROLS INCLUDING STARTERS, AS WELL AS ALL CONTROL
WIRING FOR HVAC EQUIPMENT. THE MECHANICAL CONTRACTOR SHALL PROVIDE POWER WIRING FROM THE ELECTRICAL
DISTRIBUTION SYSTEM THROUGH THE CONTROLLER TO THE ELECTRICAL LOAD AND TEST FOR PROPER ROTATION.
1.4 SHOP DRAWINGS
THE CONTRACTOR SHALL SUBMIT WITH A LETTER OF TRANSMITTAL TO THE ARCHITECT, THREE (3) SETS OF SHOP DRAWINGS
CONTAINING ALL CAPACITIES, PERFORMANCES, FEATURES, OPTIONS, ACCESSORIES, AND TECHNICAL DATA OF ALL MATERIALS
AND EQUIPMENT LISTED HEREIN. NO WORK INVOLVING ANY MATERIALS AND EQUIPMENT COVERED BY SHOP DRAWINGS SHALL
BE STARTED UNTIL THE RESPECTIVE DRAWINGS ARE APPROVED
1.5 VISIT TO THE SITE
PRIOR TO SUBMISSION OF HIS BID, THE CONTRACTOR SHALL VISIT THE SITE TO ACQUAINT HIMSELF WITH THE EXISTING
CONDITIONS. BIDS AS SUBMITTED WILL BE INTERPRETED TO INCLUDE ALL COSTS AND CHANGES MADE NECESSARY BY SUCH
CONDITIONS.
1.6 COORDINATION OF WORK
THE CONTRACTOR SHALL COORDINATE HIS WORK WITH THAT OF ALL OTHER TRADES TO ENSURE PROPER SYSTEM OPERATION
AND A COMPLETE BUILDING SYSTEM AS DESIRED BY THE ARCHITECT AND MECHANICAL ENGINEER. IN CASE OF INTERFERENCE
OR PROBLEMS THE ARCHITECT SHALL DECIDE WHICH WORK IS TO BE RELOCATED, REGARDLESS OF WHICH IS INSTALLED
FIRST.
IF ANY CHANGES ARE REQUIRED IN THE INSTALLATION OF ELECTRICAL SERVICES TO ANY MECHANICAL EQUIPMENT ACCEPTED
AS APPROVED EQUALS, THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY ADDITIONAL COSTS INCURRED OR
COORDINATION REQUIRED
1.7 PROTECTION OF EQUIPMENT
THE CONTRACTOR SHALL PROTECT ALL MATERIAL AND EQUIPMENT FROM DAMAGE UNTIL FINAL ACCEPTANCE AS INSTALLED.
HE SHALL CLOSE ALL OPENINGS DURING CONSTRUCTION WITH TEMPORARY PLUGS AND REPLACE ALL DAMAGED ITEMS WITH
ONES OF EXACT SAMENESS AT HIS EXPENSE.
1.8 OPERATING AND MAINTENANCE INSTRUCTIONS
THE CONTRACTOR SHALL PREPARE FOR THE OWNER, THREE (3) BOUND VOLUMES, EACH CONTAINING ALL INFORMATION
NECESSARY FOR THE CARE AND MAINTENANCE OF INSTALLED SYSTEMS.
AFTER COMPLETION OF THE WORK THIS CONTRACTOR SHALL INSTRUCT THE EMPLOYEES WHO HAVE CHARGE OF THE FACILITY
IN THE CARE, ADJUSTMENT AND OPERATION OF ALL PARTS OF THE SYSTEM.
1.9 CLEANING AND FINISHING
AFTER ALL TESTS HAVE BEEN MADE AND THE SYSTEM PROVEN SATISFACTORY, THE CONTRACTOR SHALL GO OVER THE ENTIRE
PROJECT, CLEAN ALL MATERIALS INSTALLED BY HIM AND LEAVE IT IN A CLEAN AND WORKING CONDITION. AT THE
COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL DISINFECT THE DOMESTIC WATER SYSTEM.
1.12 GUARANTEE
ALL WORK DONE UNDER THIS CONTRACT SHALL BE GUARANTEED BY THE RESPECTIVE CONTRACTOR AGAINST DEFECTIVE
MATERIALS AND FAULTY WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE BY OWNER. DURING
SUCH PERIOD, AND BEFORE THE EXPIRATION EACH SUCH GUARANTEE, CONTRACTOR SHALL AGREE TO MAKE ANY AND ALL
REPAIRS, ADJUSTMENTS, OR REPLACEMENTS WHICH MAY BECOME NECESSARY RESULTING FROM FAILURE OF EQUIPMENT
UNDER GUARANTEE
1.12 PROJECT CLOSEOUT
DESIGN PROFESSIONAL SHALL VERIFY FOR THE CODE OFFICIAL THAT THE SYSTEMS WERE BALANCED AND THE DOCUMENTS
LISTED BELOW WERE PROVIDED TO THE OWNER PRIOR TO OCCUPANCY. POTABLE WATER PIPING SHALL BE DISINFECTED
PRIOR TO PLACING IN SERVICE WITH CHLORINATED WATER AND FLUSHED UNTIL ALL CONNECTION POINTS RUN CLEAR.
THE MECHANICAL CONTRACTOR SHALL PROVIDE THE OWNER (OR REPRESENTATIVE) WITH THE FOLLOWING:
A. REQUIRED MAINTENANCE ACTIONS
B. OPERATION AND MAINTENANCE MANUAL
C. SYSTEM CONTROL AND MAINTENANCE CALIBRATION INFORMATION
PLUMBING FIXTURE SCHEDULE (OR APPROVED EQUAL)
MARK DESCRIPTION WASTE VENT HOT COLD
MFG / MODEL #
REMARKS
P-1 WATER CLOSET 4" 2"
-
1"
GERBER / 25-033
17" TO RIM WITH OPEN SEAT, SLOAN
FLUSHOMETER, WALL CARRIER
P-2 URINAL 2" 2" -
3
4
"
GERBER / 27-770
SLOAN FLUSHOMETER
P-3 WALL MOUNT LAVATORY 1
1
2
" 1
1
2
"
1
2
"
1
2
"
GERBER-MONTICELLO II / 12-654
MOEN FAUCET / ADA RIM AT 34"
MIXING VALVE SET TO 110°F
P-4 DROP IN SINK 1
1
2
" 1
1
2
"
1
2
"
1
2
"
GERBER / 12-844
LUXOVAL MOEN / L64601 FAUCET
MIXING VALVE SET TO 110°F
P-5 WATER COOLER 1
1
2
" 1
1
2
" -
1
2
"
HALSEY-TAYLOR / HTVZ8BLPV-NF
BI-LEVEL
P-6 KITCHENETTE SINK 1
1
2
" 1
1
2
"
1
2
"
1
2
"
DAYTON / D11719
MOEN 67425 CHATEAU FAUCET
MIXING VALVE SET TO 110°F
P-7 MOP SINK 3" 2"
1
2
"
1
2
"
FIAT / MSB2424
FLOOR MOUNT
P-8 WALL MOUNT UTILITY SINK 2" 1
1
2
"
1
2
"
1
2
"
FIAT / FL1LEG KIT, MOEN 74998 CHATEAU FAUCET
P-9 KITCHEN SINK 1
1
2
" 1
1
2
"
1
2
"
1
2
"
DAYTON / D23322
MOEN 67425 CHATEAU FAUCET
MIXING VALVE SET TO 110°F
WH-1
50 GALLON WATER HEATER - -
3
4
"
3
4
"
RHEEM / PROE50 T2 RH95 208 VOLT, EXPANSION TANK, DRAIN PAN
WH-2
20 GALLON WATER HEATER - -
3
4
"
3
4
"
RHEEM / PROE20 S2 RH95 208 VOLT, EXPANSION TANK, DRAIN PAN
FD
FLOOR DRAIN - - - -
SIOUX CHIEF / 832-2PNR
PROVENT TRAP GUARD
EUP EXTERIOR UTILITY PUMP 1
1
4
" -- -
WAYNE / EEAUP250
WITH CHECK VALVE,
120 VOLT,
1
4
HP, 7' POWER CORD
PLUMBING PIPING SCHEDULE
USE TYPE SIZE
MAXIMUM HORIZONTAL
SPACING
INSULATION SLOPE
DOMESTIC PEX TUBINGN/A 32 INCHES 1"
N/A
SANITARY PVC N/A4 FEET NONE
1
4
"
VENTING PVC N/A4 FEET NONE
1
4
"
SECTION 3 - PLUMBING EQUIPMENT
3.1 ALL VITREOUS CHINA PRODUCTS SHALL BE BY GERBER
3.2 STAINLESS STEEL SINKS BY DAYTON
3.3 DRINKING FOUNTAIN BY HALSEY-TAYLOR
3.4 SERVICE SINK / MOP BASIN BY FIAT