Spring 1-3KVAHigh Performance Line-Interactive UPS
with Pure Sinewave Output
High power density UPS with 0.9 load power factor
Rotatable LCD display with 2-colors indicating for operating
Pure Sinewave Output in less than 3% THD
2U Rack-Tower 2-in-1 with internal battery
Easy battery replacement and backup time extention
Auto Self-monitoring and diagnosis
Load segments control for outlets
Energy Saving function
Settable Line sensitivity and parameters
EPO connector for Emergency Power Off
Main Features Series –Features
MODELSpring 1KVA
Spring 1.5KVA Spring 2KVA Spring 3KVA
CAPACITY VA/W 1000VA/900W 1500VA/1350W 2000VA/1800W 3000VA/2700W
INPUTNominal Voltage 220/230/240VAC
Voltage Range184-276VAC (Standard Mode /
161-276VAC (Wide Mode)
OUTPUT
Voltage 220/230/240VAC
Voltage Regulation Battery Mode: +/-5% Typical
Frequency 50Hz or 60Hz
Overload CapacityLine Mode: 110%: 3m ; 110%-150%: 10 cycles
Battery Mode: 110%: 30S ; >120%: 5 cycles
Output THDv Linear Load: 3%, Non-Linear Load: 6% (Before low battery)
Output Waveform Pure Sine-wave
BATTERY & CHARGER
Charger Type Three Stage Profile (CC/CV/Floating)
Charger Current 1.5A for Standard mode
Battery Type 12V/7AH x3 12V/9AH x3 12V/7AH x6 12V/9AH x6
Full Load Backup Time
4’50” 2’40” 4’50” 2’40”
TRANSFER TIME Typical 2-6ms Typical
EFFICIENCYLine mode >97%
Battery Mode >80%
INDICATOR LCD Display User Friendly LCD Display
PHYSICALDimension (DxWxH) 430 x 86.5 x 438 mm 600 x 86.5 x 438 mm
Net Weight (kgs) 16Kg 22Kg 30Kg 41Kg
ENVIRONMENTOperating Environment
0- 40°C, 0-90 % relative humidity (non-condensing)
Noise Level Line mode: 45 dB, Battery mode:50 dB
Data-Sheets Series – Specification
Front and Back Viewing 1-3K
LS1OUTPUT
250V~10A
INOUT
NETWORK/TELEPHONEPROTECTION
RS232USB
INPUT220-240V~
1000VA
1500VA
2000VA
3000VA
Simulated Dot-Matrix LCD display
52mm
25mm
Different conditions (2-colors LCD display)
NMC SNMP(Network Management
Card)
NMC SNMP Introduction
NMC SNMP is a UPS monitoring accessory to link UPS via Ethernet which provides access information and configuration for the UPS.
NMC comes with an application program which named SPS (System Protect Software) for multi-servers (OS) shutdown purpose.
Communication
UPS Management and Configuration through Ethernet by SNMP Protocol
Standard MIB (RFC1628.mib) Compatible
Record Logs for Analysis
Support Http/Https - Web browser
Warning Notification via E-mail
Support SNMPv1/SNMPv2c/SNMPv3 Protocols
Support Multi-OS Shutdown by SPS
Support Shutdown in VMware by SPS
WinPowerProfessional UPS
software
Winpower Introduction
Winpower is a free download UPS monitoring software which supports either stand alone computers or network (including LAN & Internet) connected computers.
http://www.ups-software-download.com/
Software details
Real Time Remote Monitoring for UPS
Scheduled System Shutdown/Restart/UPS Test
Record Logs for Analysis
Warning Notification via SMS/E-mail/Broadcast
Support Password Security Protection
Support Central Monitoring for SNMP Card
Support Shutdown for Different OS
Support Shutdown in VMware
AS400 Card (Dry Contact Signal Card )
AS400 CARD
This card provides dry-contact signal
Pin# Description 1 UPS failure 2 Fault alarm 3 Reversed 4 Reversed 5 Gnd 6 Reversed 7 Battery low 8 UPS on 9 Utility faliure