Upload
leslie-hopper
View
22
Download
2
Tags:
Embed Size (px)
DESCRIPTION
New product on the market :. November 2004. EPP History. EPP2 1985 Innovative technology Automotive assembly industry. EPP History. EPP3 1989 Technology improvements Range extension Specific developments New markets Reliability. A New Step. Reduced size Lower consumption - PowerPoint PPT Presentation
Citation preview
New product on the market :
November 2004
2Fluid Control Division Europe EPP4 presentation.ppt - 26.11.04
EPP History
• EPP2• 1985• Innovative technology• Automotive assembly
industry
3Fluid Control Division Europe EPP4 presentation.ppt - 26.11.04
EPP History
• EPP3• 1989• Technology improvements• Range extension• Specific developments• New markets• Reliability
4Fluid Control Division Europe EPP4 presentation.ppt - 26.11.04
A New Step
• Reduced size• Lower consumption• Latest technologies• New materials
5Fluid Control Division Europe EPP4 presentation.ppt - 26.11.04
EPP4 basic Vs EPP3
Serie
• EPP3Reference
• EPP3JC21U10010
Serie
• EPP4 basicReference
• P4BG2001A002
6Fluid Control Division Europe EPP4 presentation.ppt - 26.11.04
EPP4 basic Vs EPP3
• Mechanical specifications
Fitting G 1/4'’ G 1/4'’
Flow m3/h 125 70
Pressures (bar) 0.2 – 10 0.05 – 10
Hysteresis 1% F.S. 50 mbar
Technology servo servo
Temperatures 0°C up to 50°C 0°C up to 50°C
Filtration 50 m 50 m
Consumption 0 0
Bracket L DIN
7Fluid Control Division Europe EPP4 presentation.ppt - 26.11.04
EPP4 basic Vs EPP3
• Electrical specifications
Supply voltage 24V DC 24V DC
Power consumption (work) 6 W 2.2 W
Power consumption (still) 1 W < 0.5 W
Control signal U 0-10V (10k) or 0-10V (300k) or
Control signal I 4-20mA (0.5k) 4-20mA (0.5k)
Output signal analog option –
Connector DIN M12 – 3 pins
8Fluid Control Division Europe EPP4 presentation.ppt - 26.11.04
EPP4 basic Vs EPP3
• Settings
• Notes
• Commercial
Factory U or I ; calibration U or I ; calibration
Norms IP65 – EMC IP65 – EMC 2001
Dimensions (l x w x h) [mm] 61x92x181 60x40x87
Volume [cm3] 1015 209
Weight [g] 900 400
Listed price [€] 585 330
9Fluid Control Division Europe EPP4 presentation.ppt - 26.11.04
Components
Cover
Filling PWM valve
Gasket
M12 connector
Electronic board
Emptying PWM valve
Support
Inlet
Outlet
Exhaust
10
Fluid Control Division Europe EPP4 presentation.ppt - 26.11.04
Technology
• Same principle as EPP3
11
Fluid Control Division Europe EPP4 presentation.ppt - 26.11.04
Principles
PP
AA
RR
• Standby position
12
Fluid Control Division Europe EPP4 presentation.ppt - 26.11.04
Principles
PP
AA
RR
• Filling position
13
Fluid Control Division Europe EPP4 presentation.ppt - 26.11.04
Principles
PP
AA
RR
• Regulated position
14
Fluid Control Division Europe EPP4 presentation.ppt - 26.11.04
Principles
PP
AA
RR
• Emptying position
15
Fluid Control Division Europe EPP4 presentation.ppt - 26.11.04
Mounting Bracket
• Double function• DIN fastening• Screw fastening
Included in the package
16
Fluid Control Division Europe EPP4 presentation.ppt - 26.11.04
Competitive Advantages
• Compared to the EPP3, we gained or increased the following advantages
PRICE € 585 € 330
A decrease of 44% for the same function
SIZE 1015 cm3 209 cm3
Optimisation of all electronic and mechanical components
LATESTTECHNOLOGIES
Analogicaltechnology
Latest electronic technology,Digital controller w/ integrator
Numerous regulation strategies immediately applied to the situation
PRECISION Hysteresis at 100mbar Hysteresis at 50mbar
Improvement in the regulation strategies in the materials sealing
17
Fluid Control Division Europe EPP4 presentation.ppt - 26.11.04
Competitive Advantages
• Compared to the EPP3, we gained or increased the following advantages
LOW POWER CONSUMPTION 6 W 2.2W
Electronic components
M12 CONNECTOR DIN connector or cable gland M12
M12 connector is the new standard
LATEST EMC NORMS IEC 801-4 EN 61000-6-1…4:2001
Toughest and latest norms passed
MOUNTING BRACKET Steel bracket Plastic DIN bracket
Double function: for DIN rail or screw fastening
18
Fluid Control Division Europe EPP4 presentation.ppt - 26.11.04
• Capabilities• High reactivity due to the top regulation and the mechanical parts• Level of noise improved: new opening in medical applications
• Of course, the traditional Parker Lucifer's advantages are remaining:• Parker's sales network, dense and experienced• No air consumption with the PWM valve technology• Lucifer's brand• Experience in the PWM valve technology• Reliability• Range, large range of pressure regulators with the EPP3• After Sales Service, analysis capabilities
Competitive Advantages
19
Fluid Control Division Europe EPP4 presentation.ppt - 26.11.04
Standard Numbering
Hardware Software
1 2 3 4 5 6 7 8 9 10 11 12
P 4 B G 2 0 0 1 A 0 0 1
P 4 B G 2 0 0 1 A 0 0 1 Incremental number Incremental number
Size (1=1/8”, 2=1/4”, 4=1/2”,…) Calibration family
Fitting (G or N; Gas or NPT)
Model (basic)
Version
Family (pressure regulator)
20
Fluid Control Division Europe EPP4 presentation.ppt - 26.11.04
Special Numbering
Hardware Software
1 2 3 4 5 6 7 8 9 10 11 12
P 4 0 0 0 0 1 A S 0 0 1
P 4 0 0 0 0 1 A S 0 0 1 Incremental number Incremental number
Version Modification Special Calibration/Regulation
Family (pressure regulator)
Thank you for your attention !